HomeMy WebLinkAboutB17-2237 000-000-000Butte -Count -
Butte County Department of Development Services
PERMIT CENTER .
7 County Center Drive,,Oroville, CA 95965
Main Phone (530) 538-7601 Fax (530) 538-7785
www.buttecounty.net/dds
FORM NO
ANTI -ENTRAPMENT CERTIFICATION FORM
FOR SWIMMING -POOLS.& SPAS
The following form is required whenever a building permit is issued to construct
or repair (re -plastering) a swimming pool, toddler pool, or spa.
STATEMENT. TO BE SIGNED PRIOR TO
FINAL APPROVAL
Verification of Compliance with the "Swimming. Pool Safety Act of 2006"
(Health & Safety Code 115920'— 115929)
Site Address:
Property Owner:
Owner's Mailing Address:
Phone:
I hereby certify that the swimming pool, toddler pool, or spa located a the above-
mentioned address complies with the provisions or the "Swimming Pool Safety
Act of 2006" and has been equipped with an anti -entrapment cover meeting
the current ASME/ANSI Standard A 112.19.8 as required under the
provisions of the law and have received additional information on pool
barrier requirements.
Signed:
Signed:
Owner
Contractor
Company Name:
Date:
Date:
CONTRACTOR'S INFORMATION
California Contractor's License Number:
Mailing Address:
Phone:
Email:
Attachments: Swimming Pool Enclosure Requirements and Pool Barrier handout
Revised 7-2. n.7nl ,; Pagel of3
Swimming ]Pool Enclosure Requirements
Definitions
Approved'Safety Pool Cover: A manual or power -operated safety pool cover that meets
all of the performance standards of the American Society for Testing and Materials
(ASTM), in compliance with standard F 1346-91.
Enclosure: A fence, wall or combination thereof that isolates a swimming pool
from unauthorized access.
Exit Alarm: A device that makes an audible, continuous alarm sound on the doors
leading from the dwelling/garage or other structure to the pool enclosure, which, when
opened or left ajar, permits entry to the pool without any intervening enclosure device.
Exit alarms may be battery operated or connected to the electrical wiring of the
building.
Public Swimming Pool: A swimming pool operated for the use of the general public
.with or without charge, or for the use of the members and guests of a private club.
Public swimming pool does not include a swimming pool located on the grounds of a
private single family dwelling.
Swimming Pool or Pool: Any structure intended for swimming, recreational bathing or
other recreational use that will contain water over 18 inches in depth. Swimming pools
include in -ground and above -ground structures and include, but are not limited to, hot
tubs, spas, portable spas and non-portable wading pools.
Other terms, words, or phrases not defined shall have their. ordinarily accepted meanings
within the context with which they are used. Webster's Third New International
Dictionary of the English Language, Unabridged, copyright 1986, shall be considered as
providing ordinarily accepted meanings.
�J
Revised 7.20.2015 Page 2 of
Swimming Pool Requirements
Drowning Prevention Safety Features
Based upon California Health and Safety Code Section 115920-115929, known as the Swimming
Pool Safety Act
The County of Butte requires either a listed, approved safety pool cover* meeting
ASTM Standard F1346-91, OR a complying enclosure* which isolates the pool from
the dwelling and remaining yard,
OR a complying enclosure* which surrounds the perimeter of the pool and dwelling, with door
alarms and self-closing, self latching devices on all doors leading into the enclosure.
*Enclosures
• Minimum height of 60 inches
• Access gates shall open away from pool and have self-closing, self -latching device no lower
than 60 inches above the ground.
• Maximum vertical clearance of 2 inches from the ground to the bottom of enclosure
• No openings greater than 1/2 inch within 18 inches of the release mechanism when closed.
Gaps or voids shall not allow the passage of a 4 inch sphere.
• Outside surface shall be free of cavities or protrusions that would serve as a foothold or handhold
that could enable a child of less than 5 years of age to climb over.
• Maximum mesh size for chain link shall be a 2.25 inch square unless the fence is provided with
slats fastened at the top or bottom which reduce the openings to no more than 1.75 inches
*Pool Cover
• Shall be correctly installed per the manufacturer's instructions to prevent the access of children
under five years of age to the water.
• Shall be properly constructed to meet ASTM specifications and be labeled accordingly.
• All ties, anchors or attachment points and controls for automatic covers must be installed in a
way to prevent operating or uncovering the poll by children less than five years of age.
• The pool cover shall possess a listing that insures the original design or performance of the cover
meets. or exceeds testing as prescribed by ASTM Standard F1345-91, Section 9 Test Methods for
Safety Covers.
Door alarms or self-closing,
self -latching doors
Windows and doors
routinely closed and f
latched _ ® .
'Safety pool
cover- -
Isolation
'Perimeter
'At a minimum, one of Nese shall be provided
Revised 7.20.2015
Page 3 of 3
on
self-closing,
self -latching
(Revised 4/08)
pool
engineering
September 19, 2017
Mr. Philo Hunt
County of Butte
25 County Center Dr. '
Oroville, CA 95965-3500 r
Re: Authorization to use Pool Engineering,. Inc.
Standard Pool Structural Plan .
Dear Mr. Hunt:
By this notice Pool Engineering, Inc. and the undersigned engineer -of -record
shall he grant Euphoric Pools a limited non-exclusive and non -transferable
allowance to -utilize Pool Engineering, Inc. Standard Pool structural Plan for the
permitting and construction of the swimming pool project at the Rodgers
Residence at 120 Melrose Dr. Chico, CA.
Modification or reuse of the construction drawings without the express written
permission of the Engineer is prohibited.
If we can be of any further assistance, please do not hesitate to contact us.
Bes egards,
Fnnimmnr'c Cc!nl
Ydd
Eng'neeYi , Inc.
ache , P.E.
This letter is valid only with
engineer's signature in red ink
1201 N. Tustin Avenue, Anaheim, CA 92807
�pfESS /N
t
No.67656 '
Exp. 6130/17
\ TF oar ca,O°�/
Fax: (714) 630-6114
BUTTE
COUNTY
STEP 21 2017
DEVELOPMENT
SERVICES
Phone: (714) 630-6100
Dw r -..A– _F'n
SC,
Pool Engi,?erng, Irc.
di take precedence ober cor.Ncts with site plan.
BUTTE
COUNTY
SEP 21 2017
DEVELOPMENT
SERVICES
CEC 680.26C EMIM RNTIAL BONDING GRID
SHALL BE INSTALLED AS DESCRIBED BY THIS
CODE—THE EQUIPOTENTAIL BONDING GRID SHALL
EXTEND UNDER PAVED WALKING SURFACES
3FT HORLONTAL4Y BEYOND THE INSIDE WALLS OF
GENERAL SPECS
SIZE ( AREA DEPTH TO
SHAPE PERIMETER
TILE. SIZE
TILE COLOR
THE POOL. --
NOTE:
See the attached
Swimminf Pool Requirements
- - - ---
NOTE: swimming"pool shall comply wig
Swimming Poo/ Safety Act of 2008 & CA
Hea&6 and Safety Code, Sections 115920-
115929
Complete Anti–Entrapment Certification Form.
`_Provide to building _inspector prior to- final_ inspection
G r p ro l -e cT a l l pool molar;
I
e Prov lde., Proper bac,,Kf low p ro` ecf('8A
for i V0,IlieS.
gg
Z37
LppNIENTSERVICES
PERMS#auTrEcyE�D �O +
W
RE PL`A
+�M
BY
EUPHORIC POOLS L CENSE 1007915
CONCRETE COLOR .
POOL CAPACITY GALS.
PUMP CAPACITY G.P.M.
MOTOR H.P. H.P.
FILTER SQ. FT.
FILTER RATE G.P.M.
TURNOVER HRS.
VACUUM LINE & SKIMMER
RETURN LINE "
MAIN DRAIN "
SKIMMER MODEL
BACKWASH TO
'OF 1/2" FILL LINE
ANTI -SIPHON VALVE.
HEATER SIZE BTU
GASLINE BY: VENTED BY:
LIGHT
CLOCK.
ELECTRIC BY:'
ELECTRICAL BONDING BY: .
POOL CLEANER
169 E I ITHST CHLORINATOR
CHICO, CA 95928 GRADING DIRT WALK
5:30-228-4392 TRACTOR SIZE
NAME::;, TILE & COPING BY:
ADDRESS: 51D . . 's,�(/��• �}� DECK BY:
Esq s. -TREES, ETC.
PHONE: 5 CONCRETE REMOVAL BY:
E-MAIL: RAISED BOND BEAM YES _NO HEIGHT _ WIDTH
OWNER RESPONSIBILITIES:
TO DETERMINE APPROXIMATE, ELEVATION OF POOL ON DAY OF EXCAVATION..
POOL AREA TO BE FENCED, PER COUNTY OR CITY ORDINANCE.
GATES TO BE SELF CLOSING AND SELF LATCHING.
WET DOWN CONCRETE SHELL AT LEAST TWICE DAILY FOR 7 DAYS.
DO NOT TURN ON POOL LIGHT WHEN POOL IS EMPTY,
CUSTOMER AGREES TO THE ABOVE SPECIFICATIONS: