Loading...
HomeMy WebLinkAboutB17-2310 000-000-000} Y BUTTE �COUN1 Y rOl.l 2��1 FLOTECT/O� (4 � flfiE pR0r CO DEVELOPMENT oar A - ?� SERVICES U. Z v CLASSIFICATION 1 G16 O LICENSE NO. s, #783132 P 9l46* OF C A L I F O��` Foothill Fire Protection 170 Erma Court Chico CA 95,928 (530) 826-3013 Job Name. 1211 Martin Street _FP_9-15-17 Building FP -1 Location System 1 Contract 17-26-0094 Data File 1211 Martin Street Area 1.WXF –FP -9-15-17 PEWAIT 3UTfE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CODE COMPLIANCE DATE Z / —=By Computer Programs by Hydratec Inc. Revision: 50.52.1 Foothill Fire Protection 1211 Martin Street —FP -9-15-17 Page 1 Date HYDRAULIC CALCULATIONS for { Project name: 1211 Martin Street Location: Drawing no: FP -1 Date: 9/15/17 Design Remote area number. 1 Remote area location: Living Room Occupancy classification: RESIDENTIAL Density: .05 - Gpm/SgFt Area of application: 512 - SgFt Coverage per sprinkler: 256 - SgFt Type of sprinklers calculated. 165° 4.9K SSP No. of sprinklers calculated: 2 In -rack demand. NA - GPM Hose streams: 5 - GPM Total water required (including hose streams): 31.8 -GPM Type of system: WET Volume of dry or preaction system: NA - Gal Water supply information Date: 2-19-1988 Location: Martin Street Source: Cal Water Name of contractor. FOOTHILL FIRE PROTECTION INC. Address: 170 ERMA CT., CHICO, CA 95928 Phone number. 530.826.3013 Name of designer. Anthony Abdeen Authority having jurisdiction: Chico Fire Department Notes: (Include peaking information or gridded systems here.) @ 47.1 -Psi Computer Programs by Hydratec Inc. Revision: 50.52.1 I Water Supply Curve C �� Foothill Fire Protection Page 2 1211 Martin Street —FP -9-15-17 Date City Water Supply: Demand: C1 - Static Pressure : 60 D1 - Elevation 4.114 C2 - Residual Pressure: 50 D2 - System Flow : 26.751 C2 - Residual Flow 1007 D2 - System Pressure 47.049 Hose ( Demand ) : 5 D3 - System Demand : 31.751 Safety Margin 12.934 150 140 130 P 120 R 110 E 100 S 90 S 80 U.70 C1 R 60 C2 E 50 40 D3 30 - 20 _ _ 10 200 400 600 800 1000 1200 1400 1600 1800 FLOW (N ^ 1.85) Computer Programs by Hydratec Inc. Revision: 50.52.1 Fittings Used Summary Foothill Fire Protection 1211 Martin Street —FP -9-15-17 Page 3 Date Fitting Legend Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Abbrev. Name '/z '/< 1 1% 1'/z 2 2'/2 3 3'/z 4 5 6 8 10 12 14 16 18 '20 24 N* CPVC 90'EII Harvel -Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O* CPUC Tee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R* CPUC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0- 0 0 0 0 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.52.1 ;i Pressure / Flow Summary - STANDARD Foothill Fire Protection 1211 Martin Street -FP-9-15-17 Page 4 Date Node Elevation K -Fact Pt Pn Flow Density Area Press No. Actual Actual Req. DP02 8.5 4.9 7.05 na 13.01 0.05 256 7.05 EQ02 9.5 6.86 na DP01 8.5 4.9 7.05 na 13.01 0.05 256 7.05 EQ01 9.5 6.8 na I 2 1 9.5 K = K @ EQ01 6.8 na 13.01 3 9.5 7.65 na 4 9.5 10.61 na TOR 9.5 14.17 na BOR -4.0 25.16 na t MTR -4.0 44.25 na 5.0 TEST 0.0 47.05 na 1 9.5 K.= K @ EQ02 7.65 na 13.74 The maximum velocity is 14.31 and it occurs in the pipe between nodes 4 and TOR Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen -Williams Foothill Fire Protection 1211 Martin Street -FP-9-15-17 E Page 5 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "c" or Ftng's Pe Pv """" Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn DP02 13.01 1.101 N 7.0 1.000 7.050 K Factor = 4.90 to 150.0 0.0 7.000 -0.433 r EQ02 13.01 0.0308 0.0 8.000 0.246 Vel = 4.38 0.0 13.01 6.863 K Factor = 4.97 DP01 13.01 1.101 O 5.0 1.000 7.050 K Factor = 4.90 to 150.0 0.0 5.000 -0.433 EQ01 13.01 0.0307 0.0 6.000 0.184 Vel = 4.38 0.0 13.01 6.801 K Factor= 4.99 2 13.01 0.874 O 3.0 6.000 6.801 K Factor @ node EQ01 to 150.0 0.0 3.000 0.0 3 13.01 0.0946 0.0 9.000 0.851 Vel = 6.96 3 -0.60 0.874 2R 2.0 22.166 7.652 to 150.0 " N 7.0 12.000 0.0 4 12.41 0.0866 O 3.0 34.166 2.960 Vel = 6.64 4 14.34 0.874 N 7.0 2.930 10.612 to 150.0 0.0 7.000 0.0 TOR 26.75 0.3587 0.0 9.930 3.562 Vel = 14.31 TOR 0.0 1.101 3N 21.0 13.500 14.174 to 150.0 S 9.563 30.562 5.847 BOR 26.75 0.1165 0.0 44.062 5.135 Vel = 9.01 BOR 0.0 1.029 N 7.0 80.000 25.156 to 150.0 0.0 7.000 5.000 ' " Fixed Loss = 5 MTR 26.75 0.1620 0.0 87.000 14.092 Vel = 10.32 MTR 5.00 1.025. 0.0 20.000 44.248 Qa = 5 to 150.0 0.0 0.0 -1.732 TEST 31.75 0.2266 0.0 20.000 4.533 Vel = 12.34 0.0 31.75 47.049 K Factor = 4.63 3 0.60 0.874 O 3.0 4.000 7.652 to 150.0 0.0 3.000 0.0 1 0.6 0.0003 0.0 7.000 0.002 Vel = 0.32 1 13.74 0.874 N 7.0 18.130 7.654 K Factor @ node EQ02 to 150.0 R 1.0 8.000 0.0 4 14.34 0.1132 0.0 26.130 2.958 Vel = 7.67 0.0 14.34 10.612 K Factor = 4.40 Computer Programs by Hydratec Inc. Revision: 50.52.1