Loading...
HomeMy WebLinkAboutB17-2304 040-640-055, U BUTTE COUNTY . ,• ,, DEPARTMENT OF DEVELOPMENT SERVICES i AREA INSPECTION CARD MUST BE ON JOB SITE k' 24'Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspections is 3pm) - 1 Development Services cannot guarantee inspections on the date requested oeveiovner+r senesces Office: 530.538.7601 Fax: 530.538.7785 %vww.ButteCounty.net/dds ? Permit No: B17 -2304 r Issued: 9/27/2017 I APN: 040-640-055 i Address: 108 TAIGE WAY, CHICO Owner:. :.'SATTAH, NATHAN , Permit Type; SOLAR ROOF=RES Description: `9.7 kWRoofMount Solar Array ` ALL -PLAN REVISIONS MUST BE APPROVED, BY THE COUNTY BEFORE PROCEEDING Insvection T e . IVR ` : INSP DATE Setbacks 131 Foundations / Footings 809' Pier/Column Footings ' -122 Eufer Ground -,216, Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Sign d Pre -Slab ' " " 124 Gas Test Underground/floor 404 Gas Piping Underground/floor ' . 403 Underfloor Framing, , 149 Unde"rflooFDucts . 319 Shear Transfer 136 Under Floor Plumbing 412; Under Slab Plumbing 411 131 Blockin /Under inin 612 Tiedown/Soft Set System Do Not Install Floor Sheathing or Slab -Until Above Signed Shearwall/B.W.P.-Interior',''` 134 ShearwallB.W.P -Exterior •-' 135 Roof Nail/Drag Trusses :' 129 417 Manometer Test Do Not Install Siding/Stu cco o, -Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406,.,. " Rough Mechanical 316 Rough Electrical . 208 4 -Way Rough Framing: 128 , Gas Piping House 403 .' Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Si ned Permit Final 802 Electrical Final 803 Mechanical Final 809' Plumbing Final 813 Fire Sprinkler Test or final _ 702 Swimming Pools Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath ,142 Swimming Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre -Gun ite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 503 Pre -Plaster 507 r, Manufactured' Homes Setbacks 131 Blockin /Under inin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Skirting,,/Steps/Landings 610 Coach Info Manufactures Name: Date of Manufacture: .Model Name/Number: Serial Numbers: Length x Width: Insignia: Finals Public Works Final 538.7681 Fire De artment/CDF 538.6226 , Env. Health Final 538.7281 `> Sewer District Final xxPROJECT FINAL y *Project Final is a Certificate of Occupancy for es a tial nly) PERM ITS 'BECOiMEAULCAND %IOID I YEAR FROM THE DATE OF ISSUANCE.. IF WORK HAS COM iMENCED, YOU MAY PAN' FOR A I YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION �uTTlr Butte County Department of Development Seivices; • Pt IT CENTER: ••o {• 7 County Center Drive, iOroville; CA 95965,% CUH. Main Phonc (530) 538-7601 Fax (530) 538 7785_ f' + 1�ii�a��.hutt�lountv:n�i�dJs .', , FORM NO DBI -01 Declaration of Installation for Smoke Alarms and Carbon.'Monoxide Alarms, The newly adopted 20.13 California Residential Code'requires�the installation of Carbon j' . Monoxide Detectors :in dwelling units and in sleeping units within which fuel -burning appliances are installed and in dwelling units that have attached garages. The policy for Carbon'Monoxid ' " Alarms in Butte County states: "Any Oermit obtained in which the value of work exceeds $1000 associated with a Residential Group R Dwelling Unit or Sleeping Unit shall conform to the following 2013 California Residential Code requirements forSmoke and Carbon Monoxide Alarms(SectionR314 & R315). 2013 California Residential Code requirements for Carbon Monoxide Alarm's• R315.1 New construction: An approved carbon.monoxtdealarm shall be installed in dwelling . units and in sleeping units within which fuel -burning appliances•are installed and in dwelling ' units that have'attached garages.; R315.1.2 Power supply: For new'construction required carbon monoxide alarms shall receive_ theirprimary-,power from the building wiring where such wiring is served from a commercial' source and shall be equipped with a battery back-lip:Alarm wiring shall be directly connected to the'perrrianent building wiring without a disconnecting ;switch other than as'required forover- current protection: Eiceptions: w 1. In dwelling units where there is no commercial power supply the carbon monoxide alarm tnay be solely battery operated. 2. In existing dwelling units a carbon monoxide alarm is permitted to be solely battery operated 'where repairs or alterations do not result in the removal of walland:ce'iling finishes' ,' f or there is no access by means of attic, basement or crawl space. , . R315.1.3 Interconnection. Where more than one carbon nionoxide'alarm is reg6ired to`be installed within the dwelling unit or within a sleeping unit the alarm shall be 'interconnected in a manner that activation of one alarm shall activate all of the alarms in the individual unit.- Exception: nit.Exception: � '. , ' :. -� .' , • 1. Interconnection isnot required in existing dwelling units where repairs do not result in the' removal of wall and ceiling finishes, there is no access by means of attic basement or crawl' space., and no orevious.method for interconnection existed. R316.2 Where required in existing dwellings: Where a,permit is required for'alterations; repairs or additions exceeding one thousand dollars ($1,000); existing'dwellings or sleeping.. units that have attached garages or fuel -burning appliances shall be providedwitha carbon monoxide alarm, in accordance with Section R315.1. Carbon monoxide alarms shall only be required in the specific dwelling unit or sleeping unit for which the permit was obtained.'' R315.2.6 Alarm,requiremeks': No person shall install; market, distribute, offer for sale orlsell any carbon monoxide device in the'State of California unless the device and instructions.have been approved and'Iisted by the.State Fire Marshal:.. i . , K:WEW_WEB SITE\Building\3uilding Forms & Documenis\2014L014 Forms - Completed\DBE�DB1= 01 Declaration_for.Smoke & Carbon Monoxide Detectors"REV'D 8.13.14 AKM.doc" - — - — Page l of 2 1 Carbon monoxide alarms required by Sections R315.1 and R315.2 shall be installed in the t following locations: ; 1. Outside of each separate dwelling unit sleeping area in the immediafe'vicinity of the bedroom(s). 2. On'every level 6f.a dwelling unit Including basements. R315.1.5 Multiple-purpose alarms: Carbon monoxide alarms combined with smoke alarms shall comply with Section R315, all applicable standards, and requirements for listing and J ', approval by the Office of the State Fire Marshal, for smoke alarms. �. Butte County's Interpretation of 2013 CRC, Sections 314 &'315 for Smoke Alarms-& Carbon Monoxide Alarms: Where alterations, repairs or additions exceeding $1,000 in valuation, existing dwellings shall be retrofitted with smoke alarms and those that have attached garages or fuel-burtine appliances shall have carbon monoxide alarms installed. Existing smoke alarms can be replaced with dual function alarms for Smoke and Carbon Monoxide and in most cases will comply with the aforementioned code requirements for Carbon Monoxide Alarms, s DECLARATION-OF INSTALLATION UNDER THE PENALTY OF PERJURY ' As Owner/Contractor; V/ a affirm and declare under the penalty of perjury, under the laws of the State of California, by our signatures below as Owner/Contractor, that I/we will i comply prior, to final inspection with Items A & B as specified herein: t A. Both Owner/Contractor have read and clearly understand the aforementioned•2010 a California Residential Code (CRC) Carbon Monoxide Alarm requirements. B. Both Owner/Contractor are'responsible for installing Carbon Monoxide Alarms prior to Mal inspection as per the aforementioned building code and maintaining such installation. Smoke Alarms will alsobe installed prior to final inspection as per the 2010 C. t � -CRI .. . Smoke and Carbon Monoxide alarms are now installed in the following locations: Outside of each bedroom and carbon monoxide in the hallway t` Nathan Sattah a Owner's name (print). r 9 ate: Owner's si nature: { ` Contractor's name (print): rban Design Solar/Sean McCreary CSLB License: 893826 Contractor's signature: Date: Project Address:.108 Taiga Way Chico, CA 95928. permit `O s K:WEW_WEBSITE\Building\Building Forms & DocumentsN2014\2014 Fortrns - Completed\DBI\DBI- 1 01 Declaration for Smoke & Carbon Monoxide Detectors REV'D 8.13.14 AKM.doc Page 2of2 Y: Id DIRECTORY OF PLAN PAGES DETAILS 2016 CALIFORNIA BUILDING CODE 2016 CALIFORNIA RESIDENTIAL CODE 2016 CALIFORNIA PLUMBING CODE 2016 CALIFORNIA MECHANICAL CODE 2016 CALIFORNIA ENERGY CODE WITH 2016 CA ENERGY EFFICIENCY STNDRD. OSHA 29 CFR 1910.269 UNDERWRITERS LABORATORIES (UL) I CONTRACTOR INFORMATION I VVIYIMNIVR / ��C� SIGNATURE ") SYSTEM DETAILS SITE SPECIFICATIONS UTILITY SERVICE 1120V/240V SPLIT PHASE MAIN SERVICE PANEL (TOP -FED) 200A RATED BUSBAR 200A MAIN BREAKER [91ita iinrvGu 1Ji`,?ct _ \_. Q 3rrzngih & i F# taiga Way,, . CA 9S92-8 ` h ./ F'f°�� it Pyr PLOT PV -1 SCALE: NTS I 2 LOCALE r' PV -1 SCALE: NTS , CONSTRUCTION NOTES 1 CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO INITIATING CONSTRUCTION. �iYIIt� CONTRACTOR SHALL REVIEW ALL MANUFACTURER 2 INSTALLATION DOCUMENTS PRIOR TO INITIATING CONSTRUCTION. 3 ALL EQUIPMENT SHALL BE LISTED BY THE U.L. (OR EQUAL) AND LISTED FOR ITS SPECIFIC APPLICATION. 4 ALL EQUIPMENT SHALL BE RATED FOR THE [91ita iinrvGu 1Ji`,?ct _ \_. Q 3rrzngih & i F# taiga Way,, . CA 9S92-8 ` h ./ F'f°�� it Pyr PLOT PV -1 SCALE: NTS I 2 LOCALE r' PV -1 SCALE: NTS , CONSTRUCTION NOTES 1 CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO INITIATING CONSTRUCTION. CONTRACTOR SHALL REVIEW ALL MANUFACTURER 2 INSTALLATION DOCUMENTS PRIOR TO INITIATING CONSTRUCTION. 3 ALL EQUIPMENT SHALL BE LISTED BY THE U.L. (OR EQUAL) AND LISTED FOR ITS SPECIFIC APPLICATION. 4 ALL EQUIPMENT SHALL BE RATED FOR THE ENVIRONMENT IN WHICH IT IS INSTALLED. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE 5 WITH THE MANUFACTURER'S INSTALLATION C INSTRUCTIONS. ACCESS TO ELECTRICAL COMPONENTS OVER 150 6 VOLTS TO GROUND SHALL BE RESTRICTED TO Cl (11IAI IFIFn PERSONNEL, ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 7 VOLTS AND 90°C WET ENVIRONMENT, UNLESS Q OTHERWISE NOTED. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND 8 CONDUITS ARE NOT SPECIFIED, CONTRACTOR SHALL SIZE THEM ACCORDING TO APPLICABLE CODES. PV MODULES FRAMES SHALL BE BONDED TO RACKING 9 RAIL OR BARE COPPER G.E.C. PER THE MODULE MANUFACTURER'S LISTED INSTRUCTION SHEET. PV MODULES RACKING RAIL SHALL BE BONDED TO 10 BARE COPPER G.E.0 VIA WEEB LUG, ILSCO GBL-4DBT LAY -IN LUG, OR EQUIVALENT LISTED LUG. 11 GROUNDING ELECTRODE CONDUCTOR (G.E.C) SHALL BE CONTINUOUS AND/OR IRREVERSIBLY SPLICED ALL JUNCTION BOXES, COMBINER BOXES, AND 12 DISCONNECTS SHALL BE INSTALLED IN AN ACCESSIBLE LOCATION. 13 WORKING SPACE AROUND ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC SECTION 110.26. PROJECT DESCRIPTION THE PROPOSED SYSTEM IS A ROOF MOUNTED PHOTOVOLTAIC ARRAY. THE PHOTOVOLTAIC (PV) SYSTEM IS TO BE INSTALLED ON THE RESIDENTIALLY ZONED PROPERTY IN THE CITY OF CHICO, CALIFORNIA. THE ENERGY PRODUCED BY THE PV SYSTEM SHALL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ON-SITE ELECTRICAL EQUIPMENT VIA A LOAD SIDE CONNECTION BY WAY OF A 60A CIRCUIT BREAKER. THIS PROJECT DOES NOT INCLUDE STORAGE BATTERIES. URBAIVO1 DESIGN 50LAR CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. CO �i W W U 00 w Q C C/) WU3 Q LU C7 U Cl Q uj Q Q Q co o = U U C/3 W I (530)520-3249 Z UrbanDesign Solar, Iaic 2260 Park Avenue :Chico, CA, 905928' (530) 34.50005 License #893826 B, C=46 PROJECTINFO PV -1 0 1 STRING OF 17 0 1 STRING OF 17 SINGLE FAMILY / DWELLINGA. 273' / \\ 157' 3'-6" 11-611 3, / ROOF ACCESS POINT . / AS PER CRC R331.41 -' PV ARRAY ° `• SYSTEM LAYOUT NOTES 1 CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT 1 RESISTANT PER NEC 319.0(D). 2 CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC 310.8(C). 2 DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN 3 METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC w w DISCONNECTING MEANS PER NEC ARTICLE 690.1(E) 4 ARRAYS SHALL BE INSTALLED IN A WAY THAT ENSURES THAT PV SOURCE CONDUCTORS SHALL NOT BE READILY ACCESSIBLE. CALIFORNIA FIRE CODE NOTES IN ACCORDANCE WITH CFC 605.11.3.2.1, CFC ADDS A STATEMENT THAT 1 LADDER LOCATIONS CANNOT BE IN FRONT OF WINDOWS OR DOORS, AND CANNOT CONFLICT WITH TREE LIMBS, WIRES, OR SIGNS. THE SNAP N RACK 100 SERIES FLUSH ROOF MOUNT SYSTEM IS CLASS 2 A FIRE RATED WHEN INSTALLED WITH TYPE 1 & TYPE 2 MODULES. THE REC 30L4P PEC286WP MODULE IS TYPE 2. THUS, THE SYSTEM w w CONFORMS TO THE CLASS A FIRE RATING AS REQUIRED BY CFC. DRIVEWAY PROPERTY LINE • J -BOX 200A MAIN SERVICETO DERATE TO 175A EXTERIOR J -BOX '•; AC DISCO. (DSI) (EXTERIOR) /' \ 1'-611(1) RUN OF 0,75" EMT CONDUIT RUN ALONG SIDE 164'-2" 42'-611 : - OF HOUSE TO AC DISCO. (2) RUNS OF 10/2 MC CONDUIT RUN IN ATTIC INVERTER (11) HOMERUN TO INVERTER. . ROOF ACCESS POINT URBANCU DEsirm 50LAR CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. 'Urban'.Desig:n Solar, Inc. 2260 Falk AW'iiue` Cfuco, C- 93'928 • 030045=0005 hicense499' :82.6 I3, G46 SYSTEM LAYOUT A SYSTEM LAYOUT. p\/_ 2 PV -2 SCALE: 1" = 30'-0" 1 Y W w w Q 00 Cf) 0-m) Ln 0 �C7U Lij o ¢moo � o ._ <C `— U C� W(530)520-3249 Z 'Urban'.Desig:n Solar, Inc. 2260 Falk AW'iiue` Cfuco, C- 93'928 • 030045=0005 hicense499' :82.6 I3, G46 SYSTEM LAYOUT A SYSTEM LAYOUT. p\/_ 2 PV -2 SCALE: 1" = 30'-0" 1 Y SOLAR MODULE + POWER BOX P01-34 I I I I— PM1-34 I I 285W j 17 IN j 17 IN Q (SERIES ISERIES I I I + I + JE�U JUNCTION BOX IN AT nc) 2 I r-------------- ------i I I i I I I 2 1 � i I I , I I 11 11,40OW I I ; I � I � � INVERTER I (EXTERIOR) I � i I ; I I I ' I I I __ ------ 3 -----------' I AC DISCO. I E o (EXTERIOR) D 2 2NR6 DS1 60A I 4 I I I i TO UTILITY I , I , I , I , I KWHR I i I , I , � I 1 C61 4 � l soA r1 200A MAIN (EX) --�-- DERATE TO 175A ACG.ET TO CUSTOMER LOADS (EXIS) MAIN SERVICE 2401120V 10, 3W, TOP -FED (GROUNDING (EXTERIOR) 200A BUSBAR ELECTRODE, 200A MAIN BREAKER DRIVEN ROD, EXIS) TO BE DERATED TO 175A PHOTOVOLTAIC MODULE REF. TYP. MODULE STC POWER PTC POWER I ISC IMP VOC VMP FUSE RATING PM1 1 34 REC SOLAR REC285WP 285W 264AW I 9.54A 8.9A 39.5V 32AV 25A INVERTER REF. TYP. INVERTER GROUND AC VOLTAGE MAX OCPD SIZE MAX OUTPUT POWER MAX AC CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY 11 1 SOLAR EDGE SE1140OA-US UNGROUNDED 240VAC 60A 11,40OW 47.5A 34.5A 50OVDC 97.5% SYSTEM SUMMARY REF. TYP. ARRAY STC POWER 9,69OW ARRAY PTC POWER 8,979W ARRAY CIRCUITS 1 X 17, 1 X 17 DC STRING OPERATING CURRENTS 13.84A, 13.84A DC STRING MAX CURRENTS 15A, 15A DO DTRING Of CRATINO VOLTAOC 3GOV MAX AC OUTPUT CURRENT 47.5A MAX AC POWER OUTPUT 11,40OW CEC AC POWER OUTPUT 8,65OW OER OPTIMIZER REF. TYP. MODEL AMIZERX OUTPUT RRENT STRING VOLTAGE P01 34 1 SOLAREDGE P320 15A 350VDC OCPDS REF. TYP. POLES CURRENT RATING MAX. VOLTAGE CB1 1 2 60A 240VAC MAIN 1 2 175A 240VAC DISCONNECTS 1 INSTALLATION SHALL COMPLY WITH ALL REQUIREMENTS OF NEC 2014 AND ANY APPLICABLE LOCAL REF. TYP. POLES I CURRENT RATING MAX. VOLTAGE DS1 1 2 1 60A 240VAC GROUND FAULT PROTECTION NOTES 1 INSTALLATION SHALL COMPLY WITH ALL REQUIREMENTS OF NEC 2014 AND ANY APPLICABLE LOCAL THE SOLAREDGE SYSTEM INCLUDES GROUND FAULT DETECTION AS REFERENCED BY ARTICLE 690.5 AND REQUIRED 0 BY 690.35 (C). BECAUSE THE ARRAY CIRCUIT CONDUCTORS ARE UNGROUNDED, ONLY THE REQUIREMENTS OF 2 ARTICLE 690.35 (C) (1), (2) AND (3) APPLY. EACH POWER OPTIMIZER MONITORS ITS CONNECTED MODULES AND 1 COMMUNICATES ANY DETECTED FAULT TO THE INVERTER. THE INVERTER MONITORS THE CONDUCTORS BETWEEN 3 THE POWER OPTIMIZERS AND THE INVERTER. IN RESPONSE TO A GROUND FAULT THE INVERTER WILL CEASE TO TEMP. CORR. EXPORT POWER, SHUT DOWN THE POWER OPTIMIZERS TO ISOLATE THE FAULTED CIRCUIT, AND INDICATE THE 4 GROUND FAULT ON THE INVERTER'S DISPLAY. SCHEMATIC NOTES 1 INSTALLATION SHALL COMPLY WITH ALL REQUIREMENTS OF NEC 2014 AND ANY APPLICABLE LOCAL MAXIMUM STRING VOLTAGE OF ARRAY AT DESIGN LOW TEMPERATURE OF -4°C WOULD BE 350V. 0 INTEGRATED DC DISCONNECT IS PROVIDED WITH INVERTER. DISCONNECT IS LISTED FOR USE WITH SOLAR EDGE UL 1741 LISTED STRING INVERTERS. 2 © PHOTOVOLTAIC OUTPUT STRINGS ARE COMBINED INSIDE THE INVERTERS' DC INTEGRATED DISCONNECTS. SYSTEMS ON THE PREMISES. 3 OUTPUT OF INVERTER IS CONNECTED TO UTILITY ON LOAD SIDE OF SERVICE DISCONNECT. OIITPI IT WII I RF RAr.KFFn THRnI, GH A FOA CIRCUIT BREAKER IN THS MAIN SERVICE PANEL. MAIN BREAKER IN THE SERVICE PANEL SHALL BE DERATED FROM 200A TO 175A. TEMP. CORR. ELECTRICAL NOTES SPECIFICATIONS 1 INSTALLATION SHALL COMPLY WITH ALL REQUIREMENTS OF NEC 2014 AND ANY APPLICABLE LOCAL AMENDMENTS. DESCRIPTION MODULE INTERCONNECTION CONNECTORS SHALL BE IN COMPLIANCE WITH NEC 690.33(A) AND 2 SHALL BE POLARIZED AND NON INTERCHANGEABLE WITH RECEPTACLES IN OTHER ELECTRICAL FILL % SYSTEMS ON THE PREMISES. 3 MODULE INTERCONNECTION CONNECTORS SHALL BE OF THE LOCKING TYPE REQUIRING A TOOL TEMP. CORR. FOR OPENING IN ACCORDANCE WITH NEC 690.33(C) 4 MODULE INTERCONNECTION CONNECTORS SHALL BE MARKED "DO NOT OPEN UNDER LOAD" IN BASE ACCORDANCE WITH NEC 690.33(E). w THE CONNECTION OF ALL MODULES SHALL BE ARRANGED SO THAT THE REMOVAL OF ANY PANEL 5 OR MODULE SHALL NOT INTERRUPT A GROUNDED CONDUCTOR TO ANOTHER PHOTOVOLTAIC SOURCE CIRCUIT IN ACCORDANCE WITH NEC 690.4(C). 6 ALL EQUIPMENT IN PHOTOVOLTAIC SYSTEM SHALL BE LISTED BY AN INDEPENDENT TESTING Cn LJJC7U AGENCY. 7 THE GROUNDING ELECTRODE CONDUCTORS SHALL BE CONTINUOUS IN COMPLIANCE WITH NEC CURRENT 250.64(C) AND 250.160. AMPACITY THE OUTPUT VOLTAGE OF THE POWER OPTIMIZERS ARE REGULATED BY THE INVERTER. THEY ARE 8 NOT IMPACTED BY THE NUMBER OF MODULES IN THE STRING. THE CONTINUOUS CURRENT IS DC CIRCUIT: SERIES STRING CALCULATED BY DIVIDING THE MAXIMUM POWER BY THE VOLTAGE. 9 IMARKING WILL BE PROVIDED IN ACCORDANCE WITH CAL -FIRE SOLAR INSTALLATION GUIDELINES. CONDUCTOR SCHEDULE WITH NEC ELECTRICAL CALCULATIONS ID TYP DESCRIPTION CONDUCTOR CONDUIT NO. CNDRS. FILL % RATED OCPD EGC TEMP. CORR. FILL ADJ. CONT. MAX. BASE DERATED w 00 IN CNDT. m AMPS Cn LJJC7U W FACTOR FACTOR CURRENT CURRENT AMPACITY AMPACITY 1 2 DC CIRCUIT: SERIES STRING 10 AWG PV WIRE FREE AIR N/A NIA 15A N/A 6 AWG BARE 0.65 (62°C) 1.0 OUTPUT TO JUNCTION BOX COPPER COPPER 15A 18.75A 55A 35.75A DC CIRCUIT (TRANSITIONED): 10/2 METAL CLAD 10 AWG 2 2 JUNCTION BOX TO INVERTER COPPER FREE AIR N/A N/A 15A N/A THWN-2 0.71 (60°C) 1.0 15A 18.75A 30A 21.3A COPPER INVERTER OUTPUT: 3 1 INVERTER TO AC 6 AWG THWN-2 COPPER 0.75" DIA. EMT 3 32.8% 47.5A 60A (DS1) 8 AWG THWN-2 0.91 (40°C) 1.0 47.5A 59.37A 75A 68.25A DISCONNECT COPPER AC DISCONNECT OUTPUT: AC 6 AWG THWN-2 4 1 DISCONNECT TO POINT OF COPPER 0.75" DIA. EMT 3 32.8% 47.5A 60A (CBI) 8 AWG THWN 2 0.91 (40°C) 1.0 47.5A 59.37A 75A 68.25A CONNECTION DG222NRB COPPER ALL CONDUCTORS, OCPD SIZES AND TYPES SPECIFIED ACCORDING TO NEC ARTICLES 690.8(A)(1), NEC ARTICLE 240, AND NEC ARTICLE 690.7. URBANC 1 DESIGN 913 LAR CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. Urban Design Solar, Lic. .2260 Park Avenue Chico, CA 95928' (530)-34 ' 5- 1 OOOS License 893826 B, C�46 SINGLE -LINE DIAGRAM �l t33 cfl W V w 00 m Cn LJJC7U W � p � 00o = W(530)520-3249 Z Urban Design Solar, Lic. .2260 Park Avenue Chico, CA 95928' (530)-34 ' 5- 1 OOOS License 893826 B, C�46 SINGLE -LINE DIAGRAM �l JUNCTION BOX v JUIVU I IUIV DUA ®• WARNING. ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED NEC 690.35(F) . JUNCTION BOX ® WARNING PHOTOVOLTAIC POWER SOURCE NEC 690.35 INVERTER NEC 690•56(B) ® INTEGRATED DC DISCONNECT (INVERTER 11) INTEGRATED DC DISCONNECT (INVERTER 11) 14 MAIN SERVICE PANEL 2Q JUNCTION BOX DO NOT © DISCONNECT UNDERLOAD NEC 690.16(B) RACEWAYS & OTHER 10 RACEWAYS, CABLES PER 10 FT. 11 PV WIRE CONNECTORS DO NOT ® WARNING ® © DISCONNECT Q PHOTOVOLTAIC UNDER LOAD NEC POWER SOURCE- EC 690.16(6) NEC 690.35(F) MAIN SERVICE PANEL 12 MAIN SERVICE PANEL 13 MAIN SERVICE PANEL . A WARNING A DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM NEC 690.53 INVERTER (11) ® WARNING 'ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF .THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED NEC 690.35(F) SOLAR INVERTER MAXIMUM RATING OPERATING CURRENT 47.5AMPS OPERATING VOLTAGE 240 VAC SOLAR DC DISCONNECT NEC 690.13(B) 70 INVERTER (11) ® WARNING ELECTRIC SHOCK HAZARD IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED NEC 690.5(C) 9Q INVERTER(11) PHOTOVOLTAIC SYSTEM" EQIUPPED WITH RAPID SHUTDOWN NEC 690.54 NEC 690.56(C) A WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE ® WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.17.4 .PHOTOVOLTAIC SYSTEM AC DISCONNECT. OPERATING CURRENT 47.5AMPS OPERATING VOLTAGE 240VOLTS MAIN SERVICE PANEL 20 MAIN SERVICE PANEL © CAUTION 0 POWER TO THIS SERVICE IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN N 200A MAIN SERVICE (EXTERIOR) AC DISCO. (DS1) (EXTERIOR) . INVERTER (11) NEC 690.56(B) (EXTERIOR) NEC 705.12(D)(7) NEC 690.14(C)(2) & NEC 690.54 16 MAIN SERVICE PANEL 17 MAIN SERVICE DISCONNECT SHALL NOT BE DISCLOSED IN FULL OR IN PART 4 ® WARNING ® 5 DESIGN AND INSTALLATION OF THE PV SYSTEM MAIN BREAKER HAS BEEN REPRESENTED IN THIS PLAN. 7 WEATHER RESISTANT MATERIAL, PER UL 969' RESIZED TO 175AMPS SOLAR ELECTRIC BREAKER IS BACKFED a� DO NOT UPSIZE BREAKER co REQUIRED BY AHJ AC DISCONNECT C 18 AC DISCONNECT (DS1) 19 ' AC DISCONNECT (DSI) PHOTOVOLTAIC SYSTEM AC DISCONNECT OPERATING CURRENT 47.5AMPS OPERATING VOLTAGE 240VOLTS NEC 690.54 A WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.17.4 URBAN�1 DE5161V SOLAR UrbanDesign Solar, Ine 2260 Sark AWeuue C ico,.CA 9S929' '. ,1530} 345=QQ05 Liceiise.#893826 B, C-46 1 CONFIDENTIAL: THE INFORMATION CONTAINED 2 IN THIS DRAWING SET IS CONFIDENTIAL AND 3 SHALL NOT BE DISCLOSED IN FULL OR IN PART 4 TO ANYONE EXCEPT THOSE INVOLVED IN THE 5 DESIGN AND INSTALLATION OF THE PV SYSTEM 6 REPRESENTED IN THIS PLAN. 7 WEATHER RESISTANT MATERIAL, PER UL 969' a� co 07 UJ I C 00 w Q (ODLoW 0j.W C C/) LUuj C7 U 000U O _ F— � U C7 U) U) W (530)520-3249 z UrbanDesign Solar, Ine 2260 Sark AWeuue C ico,.CA 9S929' '. ,1530} 345=QQ05 Liceiise.#893826 B, C-46 1 SIGNAGE REQUIREMENTS ALL PLACARDS AND SIGNAGE REQUIRED BY THE 2016 CEC, 2014 NEC, AND ANY OTHER STATE CODES OR LOCAL ORDINANCES.WILL BE INSTALLED AS REQUIRED. 2 RED BACKGROUND 3 WHITE LETTERING 4 MINIMUM 3/8" LETTER HEIGHT 5 ALL CAPITAL LETTERS 6 AERIAL OR SIMILAR FONT 7 WEATHER RESISTANT MATERIAL, PER UL 969' PLACARDS PROJECT NO: GSD -20170926-70972 DRAWN BY: SCM DATE: 9/26/2017 1 PLACARDS PV -4 SCALE: NTS PV -4 LAYOUT SPECIFICATIONS ROOF INFORMATION ROOF TYPE COMPOSITE SHINGLE PITCH 28" (6:12) RAFTER SPACING 24" O.C. RAFTER DIMENSIONS 2"X 4" LAYERS OF ROOFING 1 LAYOUT SPECIFICATIONS NUMBER OF MODULES 34 NUMBER OF MID -CLAMPS 56 NUMBER OF END -CLAMPS 24 NUMBER OF ATTACHMENTS 50 AREA 1612 SQ. FT STRUCTURAL CALCULATIONS WIND EXPOSURE CATEGORY B DESIGN WIND SPEED 120 MPH (3 -SECOND GUST) ROOF DESIGN SNOW LOAD 0 PSF (VALLEY FLOOR) TOTAL WEIGHT OF ARRAY 1649 LBS POINT LOAD 33.0 LBS DEAD LOAD 12.70 PSF URBANDE516N 50LAR URBAN DESIGN SOLAR PHONE: 530 345-0005 LICENSE NO. 893826 B C46 CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. Y u� Co W U 00 W W LoQ cn Cn W Q fn00 U U elfQ o L7 U W(530)520-3249 Z CONTRACTOR OF RECORD AS PER CRC R331.41 Urban Design Solar,_ Inc: IZ6O Park Avenue :Ctico;`CA 95928 WOY45=0005 Lice>t�se:;f893826 B,.C--46 _. rvrn C_ 7 ATTACHMENT NOTES 1 ROOF MEMBERS AND PENETRATIONS TO BE DETERMINED IN THE FIELD. 2 LAG SCREWS SHALL BE 5/16'X 3.5" WITH A 2.5 INCH MINIMUM EMBEDMENT. 3 THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 4 FLASHING SHALL BE APPLIED IN ACCORDANCE WITH MANUFACTURERS' PRINTED INSTRUCTIONS. 5 IF THERE IS ANY CONFLICT BETWEEN WHAT IS DEPICTED HERE AND INSTRUCTIONS PROVIDED BY THE MANUFACTURER, MANUFACTURERS' INSTRUCTIONS SHALL SUPERCEDE. 6 THE ROOF HAS A SINGLE ROOF COVERING WITHOUT A REROOF OVERLAY. ATTACHMENT PLAN PROJECT NO: GSD -20170926-70972 DRAWN BY: SCM DATE: 9/26/2017 1 ATTACHMENT PLAN PV -5 PV -5 SCALE: 1" = 8' • URBAN DEsim MODULE END CLAMP SOLAR i I i i i i i i I I I I l i GROUNDING LUG & COMPOSITION ROOF i I I I I i I i MODULE MID CLAMP URBAN DESIGN SOLAR - SNAP N RACK L FOOT PHONE: 530 345-0005 o - - - - LICENSE N0.893826 B C-46 2411 MAX I MAX I I I I I PV MODULE TYP. j i CONFIDENTIAL: THE INFORMATION CONTAINED I I I i I I 11 I I 24 O.C. �i j I I I I I I MODULE MID CLAMP i IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART I I I i RACKING RAIL SNAP N RACK TO ANYONE EXCEPT THOSE INVOLVED IN THE L -FOOT IIIIiII I i STANDARD RAIL SNAP N RACK FLSHING DEcSflIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. FLASHING SKIP SHEATING IIiIIi 5116" SS LAG SCREW ij-111, MIN 2 -112" THREAD PENETRATION -III�III - i iIIIIII SEALED WIVULKEM CAULKING (OR EQUIV.)Cn Lu i i i i i II i i i W U 00 1 n I 1±411 T i I i I I I I i i i i I i I I I t i i Cl Lu Q I I I I I I I I I I C� 0 LU �� V 72° MAX. "RAFTER D Q0 co C _ U A MOUNTING PLAN VIEW PORTRAIT c MOUNTING METHOD C9 cn PV -6 SCALE: 1" = 1'-6" PV -6 SCALE: V= 2'-0" W (530) 520-3249 Z 5.25" C CONTRACTOR OF RECORD Urban'Design Solar, Inq 2260 Park 4euue :Chico; CA 9S928* License: -#893826 B, t-46 \ON�O�F • �R@24, pG. . 2, MOUNTING & RACKING PROJECT NO: GSD -20170926-70972 DRAWN BY: SCM DATE: 912612017 B MOUNTING METHOD PV -6 SCALE: 1"=2'-O" SnapNrack-..'. � 4 Solar Mounting Solutions _ - r - • - .. • SnapNrack- Series 100 Residential Roof Mount System Solar Mounting Solutions The SnapNrack Series 100 Roof Mount System is engineered to optimize material use, t labor resources and aesthetic appeal. This innovative system simplifies the process of installing solar modules, shortens installation times, and lowers installation costs; maximizing productivity and profits. The Series 100 Roof Mount System boasts unique, pre -assembled, stainless steel "Snap - In" hardware and watertight flash attachments. This system is installed with a single tool. No cutting or drilling means less rail waste. It is fully integrated with built-in wire management, solutions for all roof types, one -size -fits -all features, and can withstand extreme environmental conditions. Series 100 is listed to UL Standard 2703 for Grounding/Bonding, Fire Classification and Mechanical Loading. UL 2703 Certification and Compliance ensures that SnapNrack installers can continue to provide the best in - - class installations in quality, safety and efficiency. O Appealing design with built-in aesthetics f O No grounding lugs required for modules O All bonding hardware is fully integrated . O Rail splices bond rails together, no rail jumpers required O No drilling of rail or reaching for other tools required . O Class A Fire Rating for Type 1 and 2 modules URBANUflPDESIGN SOLAR • URBAN DESIGN SOLAR PHONE: 530 345-0005 LICENSE NO. 893826 B C-46 CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND U - - SHALL NOT BE DISCLOSED IN FULL OR IN PART Bonding Splice Stainless Bolt with SPIIt-Lock Washer Standard Rail Stainless Steel Bolt with Insert Bonding Adjustable End ClamppTopTop BondingAdjustableBonding End ClamppBottom _ / lock Washer Bonding Mid Clamp Channel Nut _ Bonding Adjustable Bon/, ding Mid Clamp - End Clelnp z•zmoer C.0 z•sozoss URBANUflPDESIGN SOLAR • URBAN DESIGN SOLAR PHONE: 530 345-0005 LICENSE NO. 893826 B C-46 CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND U - - SHALL NOT BE DISCLOSED IN FULL OR IN PART Bonding Splice Standard Rail Insert 06-09816 - Splice - Base C.0 9` W i. Bonding WW ;H Stainless Channel Nut Q Stainless Hardware with Cn Bolt with Split -Lock Washers U3 W Q Split Lock C1 BondingStandard Washer Q Rall Splice W Ground Lug µ z•x ots Q co U 2a2.02101 12-6 AWG _ Copper Wire ¢ U - C.7 Ground Lug Assembly (ONE REOUIRED PER RO W OF MODULES) (530)520-3249 Universal End Clamp (UEC) wave j' UECPuIIStrap - UEC Wedge Stainless Steel Bolt with Flat Washer UniversalEntl Clamp z.z.azaa Standoff Camp Assembly - Rubber Serrated Stainless 0& Channel Channel Nut Rain Collar Steel Flange Nut Nut Stainless Serrated Stainless FWnge Nut Mill Finish`' Steel Flange Bolt 92 Degree Stainless Standoff L Foot Flange Boit All Purpose L Foot Mill Finish Standoff Base (1 -Hole WLFt Metal Roof Base Shown) Mill FBase Assembly L Foot Bess FWsNng Standoff L L FootBase wlUl Flashing Metal Roof Base 2-Ina.z•zsroso with L Foot SOHISn TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. 1 ti Y C.0 W WW U 00 � Q Cn U3 W Q C1 UJ C7 U Q W . µ Q Q co U O � ¢ U - C.7 � LU (530)520-3249 Urban'Design 861ar, Lic: ' .2260 Park Aweuue Chic% CA 9S928RAW �P JS30) X45-OOOS • 6000 Series aluminum License #893'826 B, C-46 Materials • Stainless steel • Galvanized steel and aluminum flashing > - System.Features,lnclude k• Silver and black anodized aluminum h,; • .( jyl�Go� Mill finish select products Material Finish , , - • 1 * • - •Silver or, blala ck coated hardware , t r= • Note: Appearance of mill finish products may vary and change over time. . Snap in Single Tool Easy No Cutting + Hardware - Installation Leveling or Drilling Wind Loads 110 - 190 mph (ASCE 7-10) j RACKING DATASHEET Snow Loads. 0 - 120 psflip - ® Array Pitch 0 -'66 degrees Integrated Wire Preassembled Integrated bonding UL 2703 Certified - PROJECT NO: GSD -20170926-70972 Management hardware Resources snapnrack.com/resources 1 Design snapnrack.com/configurator 1 Where to Buy snapnrack.com/where-to-buy r 877-732-2860 111 www.snapnrack.com I contact@snapnraek.com- DRAWN BY: SCM © 2016 by SnapNrack Solar Mounting Solutions. All rights reserved S^.sask9elas-igg-aad--Ll DATE: 912612017 RACKING DATASHEET - r• PV-7 PV-7 SCALE: NTS ` . ;• .,. _ ' .*� r' •. , - , : ; - :. `•• URBAN 1 DE516N rW URBAN DESIGN SOLAR ' PHONE: 530 345-0005 REC TWINPEAK .2- SERIES' LICENSE N0.893826 B C-46 �, ....r. CONFIDENTIAL: THE INFORMATION CONTAINED ` IN THIS DRAWING SET IS CONFIDENTIAL AND 910(3591 '3a ts.051 . n _ t a E] lo.xllo9l . 3oszo t- - ,!g I0.78 10.0e1 1300147 - Mnrsuc,.sntsFamf+tl ti �3ellsl ELECTRICAL BATA@ STC- 275 WP 280WP 29OWP NominalPower-P„r,(Wp) 275 _280 285 290 Watt Class Sorting -(W) 0/+5 0/+5 0/+5 0/+5 Nominal PowerVoltage_V_(V) 31.5 _31.7- _ 31.9 _ 32.1 Nominal Power Current-I_(A) 8.74 8.84 8.9s7 9.05 Open CircuitVoltage-VaIV) , 38.2 38.4 38.6 38.8 ShortCircuitCument-Ix(A) 9.30 9.3_9 - 9.49 9.58 Panel Efficiency(%) 16.5 16.8 17.1 17.4 vaW.atst.dardte,tconddonsSTC(almossAMI5,brada e1000W/m),celltemperatwe25•C} - At lowirradlance of 200 W/m'(AM 15 and cell temperature SY) at least 94%of the STC module efficlenrywlll beaW eyed 7mduct mde, REC-TP2, where x x x Is the watt class shorn an be followed by the suffix OL< for black framed model es. ELECTRICAL DAfi'? NOCT 27S WP :, WP 285WP 290 WP • NominalPower-P.(Wp) 206 210 214 218 Nominal PowerVoltage-V_(VI 29.2 29.4 29.6 29.8 Nominal PowerCurrent -1,(A) 7.07 7.15 7.24 7_.32 4 Open CircuRvoltage-Va(V) 35.4 }' 35.6 35.8 36.0 Short Circuit Curren[ -1.(A) ^, 7.52 7.59. 7.68 _ ' 7.75 ' - Nominal • at'' cent r ' oyer ulg emperaturetlOCT(600W/m'.AMI.S,windspeedlrtl/z,amblmttemperature 20•C} , ' •Producicode,RECxxxTP2wherexxx is dcewattclass0-1m. can be followed Mthewffa1marbtackframedmodudes , CERTIFICATIONS ��❑e 10 year product warranty ❑ UVE crus j y 25 year linear power output warranty (max. degression in performance of0.7%p.a. from 97% - - UL 17D3,Flre dasslficatlon Type 2; IEC 61215, IEC 61730 -er ,' after the first year) :EC 0701 (Salt Mlst-severity 1-161 IEC 62604(PID Free). 5mwa antyconditlonsfo furtherdetails ` ,IEC 62716(Ada Resistance), 1501195-2(IgnitabilityClass l) numr" r UN10457/9174(ClassA).1509001;2015.15014001,0HSASI6001 �� .�.+�p+'- �! s--+ . ' SHALL NOT BE DISCLOSED IN FULL OR IN PART " TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN, r lie a V / LU F 3 LU L >- C ` CJ w L0 07 i- U) LU Q U:) LUC7U LU V r s • (D C/3 W(530)520-3249 CONTRACTOR OF RECORD ' CTr&aabesip 96.1ar,•Lic 2260 Park Avenue ' k 'Chico, CA 95928.. (�30� 345=0005,;. License:#893826 B, G46 • Celebrating its 20th anniversary in 2016, REC is a leading European brand of solar'panels. Through integrated manufacturing from ers,clls.panelsandturnkeysolarsolutions,RECstrivestohelpmeetthewarld'sgrowingenergyneeds.Foundedin1996.RECisaBluesfamy® RCC EypqSingapore. concluded - •" r AA with 2000 employees worldwide. 1.3 GW solar panel production capacity, and annual revenues ofUSD 755 million. MODULE DATASHEET ywww.recgroup.com _ PROJECT NO: GSD -20170926-70972 y DRAWN BY: SCM - r , ,♦ DATE: 9/26/2017 z' y •• l MODULE DATASHEET • PV -8 SCALE'NTS. NTS. P_ 8 _ Mnrsuc,.sntsFamf+tl ti �3ellsl ELECTRICAL BATA@ STC- 275 WP 280WP 29OWP NominalPower-P„r,(Wp) 275 _280 285 290 Watt Class Sorting -(W) 0/+5 0/+5 0/+5 0/+5 Nominal PowerVoltage_V_(V) 31.5 _31.7- _ 31.9 _ 32.1 Nominal Power Current-I_(A) 8.74 8.84 8.9s7 9.05 Open CircuitVoltage-VaIV) , 38.2 38.4 38.6 38.8 ShortCircuitCument-Ix(A) 9.30 9.3_9 - 9.49 9.58 Panel Efficiency(%) 16.5 16.8 17.1 17.4 vaW.atst.dardte,tconddonsSTC(almossAMI5,brada e1000W/m),celltemperatwe25•C} - At lowirradlance of 200 W/m'(AM 15 and cell temperature SY) at least 94%of the STC module efficlenrywlll beaW eyed 7mduct mde, REC-TP2, where x x x Is the watt class shorn an be followed by the suffix OL< for black framed model es. ELECTRICAL DAfi'? NOCT 27S WP :, WP 285WP 290 WP • NominalPower-P.(Wp) 206 210 214 218 Nominal PowerVoltage-V_(VI 29.2 29.4 29.6 29.8 Nominal PowerCurrent -1,(A) 7.07 7.15 7.24 7_.32 4 Open CircuRvoltage-Va(V) 35.4 }' 35.6 35.8 36.0 Short Circuit Curren[ -1.(A) ^, 7.52 7.59. 7.68 _ ' 7.75 ' - Nominal • at'' cent r ' oyer ulg emperaturetlOCT(600W/m'.AMI.S,windspeedlrtl/z,amblmttemperature 20•C} , ' •Producicode,RECxxxTP2wherexxx is dcewattclass0-1m. can be followed Mthewffa1marbtackframedmodudes , CERTIFICATIONS ��❑e 10 year product warranty ❑ UVE crus j y 25 year linear power output warranty (max. degression in performance of0.7%p.a. from 97% - - UL 17D3,Flre dasslficatlon Type 2; IEC 61215, IEC 61730 -er ,' after the first year) :EC 0701 (Salt Mlst-severity 1-161 IEC 62604(PID Free). 5mwa antyconditlonsfo furtherdetails ` ,IEC 62716(Ada Resistance), 1501195-2(IgnitabilityClass l) numr" r UN10457/9174(ClassA).1509001;2015.15014001,0HSASI6001 �� .�.+�p+'- �! s--+ . ' SHALL NOT BE DISCLOSED IN FULL OR IN PART " TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN, r lie a V / LU F 3 LU L >- C ` CJ w L0 07 i- U) LU Q U:) LUC7U LU V r s • (D C/3 W(530)520-3249 CONTRACTOR OF RECORD ' CTr&aabesip 96.1ar,•Lic 2260 Park Avenue ' k 'Chico, CA 95928.. (�30� 345=0005,;. License:#893826 B, G46 • Celebrating its 20th anniversary in 2016, REC is a leading European brand of solar'panels. Through integrated manufacturing from ers,clls.panelsandturnkeysolarsolutions,RECstrivestohelpmeetthewarld'sgrowingenergyneeds.Foundedin1996.RECisaBluesfamy® RCC EypqSingapore. concluded - •" r AA with 2000 employees worldwide. 1.3 GW solar panel production capacity, and annual revenues ofUSD 755 million. MODULE DATASHEET ywww.recgroup.com _ PROJECT NO: GSD -20170926-70972 y DRAWN BY: SCM - r , ,♦ DATE: 9/26/2017 z' y •• l MODULE DATASHEET • PV -8 SCALE'NTS. NTS. P_ 8 _ ' SHALL NOT BE DISCLOSED IN FULL OR IN PART " TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN, r lie a V / LU F 3 LU L >- C ` CJ w L0 07 i- U) LU Q U:) LUC7U LU V r s • (D C/3 W(530)520-3249 CONTRACTOR OF RECORD ' CTr&aabesip 96.1ar,•Lic 2260 Park Avenue ' k 'Chico, CA 95928.. (�30� 345=0005,;. License:#893826 B, G46 • Celebrating its 20th anniversary in 2016, REC is a leading European brand of solar'panels. Through integrated manufacturing from ers,clls.panelsandturnkeysolarsolutions,RECstrivestohelpmeetthewarld'sgrowingenergyneeds.Foundedin1996.RECisaBluesfamy® RCC EypqSingapore. concluded - •" r AA with 2000 employees worldwide. 1.3 GW solar panel production capacity, and annual revenues ofUSD 755 million. MODULE DATASHEET ywww.recgroup.com _ PROJECT NO: GSD -20170926-70972 y DRAWN BY: SCM - r , ,♦ DATE: 9/26/2017 z' y •• l MODULE DATASHEET • PV -8 SCALE'NTS. NTS. P_ 8 _ solar-.. z • SolarEdge Single Phasile Inverters - For North America SE3000A-US SE380OA-US / SE5000A-US / SE6000A-US SE760OA-US SE110000A-LISSE11400A-Ul] The best choice for Solarlidg6. 6na bled systems. Integrated arc fault protiictiodfor NEC 2011 690.1l.complianc . e Rapid shutdown for NEC 2014 690.12 Superior efficiency (98%) - Small, lightweight and easy to install on provided bracket Built-in module -level monitoring Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter, DC/AC conversion only T Pre -assembled Safety Switch for faster installation Optional — revenue grade data, ANSI C12.1 .USA -GERMANY -ITAILY -FRANCE -JAPAN -CHINA -AUSTRALIA -THE NETHERLANDS -UK -ISRAEL w . wwsolaredge.us 183.208 - 229 Vac.................... . . URBANMDE51151Y fpr art -jests ............... ..... ........... % .... ... ; ............. .... ...... ................. ............ SOLAR I....... I solar Single Phase Inverters for North America ..................... ' AC Frequency Min . .... . .... ....... ..... .............. ............... ............... .... . ... ......... ................ ............... ............ ... 59.3 - 60 - 60.S .......... .......... Hz =ee z : i4 i6iVh 12 4 7:5 �! .... I A URBAN DESIGN SOLAR 11 .... SE300OA-US/SE380OA-US/SE500OA-US/SE600OA-US/ T111- 1W PHONE: (530) 345-0005 GFDI ........... .. ...................... 1 ..... .......... ............... ................ ............... ............... ..... ........... A SE7600A-US/SE10000A-US/SE11400A-US Utility Monitoring, Islanding Protection, ................. Country Configurable Thresholds Yes LICENSE NO. 893826 (13, C46) CONFIDENTIAL: THE INFORMATION CONTAINED I SE3000A-US I SE3800A-US SESOOOA-US I SEroOOA-US SE7600A-US SE20000A- US r=S=E=11400A-U,=fl INPUT Maxim ........ Ym.9�q P9wer!Sm ......... I OUTPUT- I Transformer less Ungrounded ........ IN THIS DRAWING SET IS CONFIDENTIAL AND ....... I Nominal AC Power Output 3000 I 3800 5000 6060 7600 9980 @ 208V 11400 VA 1 Max Input Voltage .................... SHALL NOT BE DISCLOSED IN FULL OR IN PART ... �4 .... C .................................. ............... -Max. AC Power Output 3300 ............... ........... ............... ............... saoo @ 208V ......... ....... 4150 6000 8350 10800 @ 208V 12000- VA Nom. DC Input Volaeiu ................ TO ANYONE EXCEPT THOSE INVOLVED IN THE ...... V.d.c *M ­17n,., ................ Max. Input Current") DESIGN AND INSTALLATION OF THE PV SYSTEM ... ... Adc N**o­nl'.-' 10"a, AC 6U't'P'uI'V­c ii;lie' x. . . ......... .................... ......................................... Max. Input Short Circuit Current REPRESENTED IN THIS PLAN. .......... The best choice for Solarlidg6. 6na bled systems. Integrated arc fault protiictiodfor NEC 2011 690.1l.complianc . e Rapid shutdown for NEC 2014 690.12 Superior efficiency (98%) - Small, lightweight and easy to install on provided bracket Built-in module -level monitoring Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter, DC/AC conversion only T Pre -assembled Safety Switch for faster installation Optional — revenue grade data, ANSI C12.1 .USA -GERMANY -ITAILY -FRANCE -JAPAN -CHINA -AUSTRALIA -THE NETHERLANDS -UK -ISRAEL w . wwsolaredge.us 183.208 - 229 Vac.................... . . fpr art -jests ............... ..... ........... % .... ... ; ............. .... ...... ................. ............ _..'��-.2.64.V.a.c I....... I I. ..................... ' AC Frequency Min . .... . .... ....... ..... .............. ............... ............... .... . ... ......... ................ ............... ............ ... 59.3 - 60 - 60.S .......... .......... Hz Max Continuou,s,0utp,u.tCurr ent : i4 i6iVh 12 4 7:5 �! .... I A 11 .... ..... ...... ...... .. Alm mw .. ...... ... :­­ I -------------- . ...... I .......... T111- 1W The best choice for Solarlidg6. 6na bled systems. Integrated arc fault protiictiodfor NEC 2011 690.1l.complianc . e Rapid shutdown for NEC 2014 690.12 Superior efficiency (98%) - Small, lightweight and easy to install on provided bracket Built-in module -level monitoring Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter, DC/AC conversion only T Pre -assembled Safety Switch for faster installation Optional — revenue grade data, ANSI C12.1 .USA -GERMANY -ITAILY -FRANCE -JAPAN -CHINA -AUSTRALIA -THE NETHERLANDS -UK -ISRAEL w . wwsolaredge.us 183.208 - 229 Vac.................... . . Ac Output Voltage Min.-Nom.-Max.(1) ............... ..... ........... % .... ... ; ............. .... ...... ................. ............ _..'��-.2.64.V.a.c I....... I I. ..................... ' AC Frequency Min . .... . .... ....... ..... .............. ............... ............... .... . ... ......... ................ ............... ............ ... 59.3 - 60 - 60.S .......... .......... Hz Max Continuou,s,0utp,u.tCurr ent : i4 i6iVh 12 4 7:5 �! .... I A 11 .... ..... ...... ...... .. Alm mw .. ...... ... :­­ I -------------- . ...... I .......... GFDI ........... .. ...................... 1 ..... .......... ............... ................ ............... ............... ..... ........... A Utility Monitoring, Islanding Protection, ................. Country Configurable Thresholds Yes LU 00 INPUT Maxim ........ Ym.9�q P9wer!Sm ......... ...... 15350 ................. W Transformer less Ungrounded ........ ............... ............... ................ ....... I Max Input Voltage .................... ....... .... ............... ................. ................. 500 ... �4 .... C LU 1117) Nom. DC Input Volaeiu ................ ....... ............... ................. ................. 325 @ 208V / 350 @ 240V ...... V.d.c U) Max. Input Current") .......... ................. 9.5 13 Yli,�,O,i6iV IS 2 34.5 15' 1 1 1- ... ... Adc U) C/) LU < ......................................... Max. Input Short Circuit Current ......... ...... * ........ .... t ........... .....45............... .. . ................. .......... LU t!.l: 45 ............. ............................... ............... ............... ................. ................. Adc ....... W ............ ....... Y�� .... ............... : ................ ..... ........... .. .. ......................... ...... LU 0 . 1-* — .M��imumjn .......... ...... ..co ...... ...............[ ...... ........ 1: 4i-* R7% .?. 98.31.....98.3.....1......98...-•• .......... 1-- - CEC Weighted Effic nc� !e ..... ..... .. ......97.5........ 97.5 97.5 9 . 9.7 .... %.... C=) .................... ............... Nighttime Power Consumption ..... .... ...... 98 :S •......... ...... ?AQY .......... <2.5• i ADDITIONAL FEATURES SyRqortecl Communication Interfaces] ............... ..... RW.5,RS23.2, Ethernet, ZigBee (optional) Revenue................. ................. .......... ............... ........ Data, ANSI C12.1 ............... ................ ........Yes ....... I ....... ................. (530) 520-3249 ................. .......... Rapid Shutdown-... Yes LU 'STANDARD COMPLIANCE Safely.................... ............. ........... Grid Connection Sta��j�.rA� .......... * ........ ­* ..... .... CONTRACTOR OF RECORD .... Emissions.............. ....... ** . ....... * ....... ................ ..... . ................ .................. .................. I INSTALLATION SPECIFICATIONS U&n --lbesip 61ar, 1jjC,, ACoutput conduit size ... I DC input / # ............... .......... minimum / 16-6 AWG ­* ............ . ­* .........• ...... 3/4" minimum / 8-3 AWG I I *jA;1 .. :­­­ "­ .......... conduit size of strings / 3/4" minimum / 1-2 strings 16-6 AWG minimum / 1-3 strings I I AWG ra S!� ............................... ........ ....... .... ­ ....... ....... ...... ........ ... A4:§.�Wq ........... I - venue Dimensions with Safety Switch 30.5 x 12.5 x 7.2 / 775 x 315 x 184 i0.5 x 12.5 x 10.5 n 122i�o ............................... Wei&h.t.with. Safe.ty Switch ........... I ............... ............... ................ ............... ............... - I . . .......... 2 54.7/24.7 775 x 315 x 260 . ...... :� ....... .............. I - _88.4/40.1- ... 1­1�%"kg­', -mm :ChicoxA 9S,928" .2 ........... ................ ............... ............... Natural ................. ................. .......... "(530)!3z -Doos convection Licensel.411 Cooling Natural Convection and Internal Fans (user replaceable), f8_53826 t C-46 fan (user ............................. ........... ............... replaceable). . ............. ............ . ...... : Noise - < 50 . ............................................ _tMin- Operating • �.. . I I - 13 to +140/25 to +60 0 to +0 version avilablej < C-C,,Range........................•_.....".•I..•:...........4) ............... ............. PR4 ....... .............. NEMA 311 .... ....... : ......... .......... ......... .......... ............... ................ ... ....... . ........... ................. ................. .......... For other regloml settings please contact SolarEdge support. A Maher current source may be used; the 1,werter will limit Its Input current to the values stated. ISI Rouenue, grade inverter PIN: SE—A-US0001,11,1112 (for 760OW lnverter:5E7600A-US002NNR2). 'rl40 version P/N: SExxxxA-U5=NNU4 (for 76WW Invert-SE7600A.1.150021,11,11,141. NVERTER DATASHEET SCM INVERTER DATASHEET. p\/ 9 SCALE: NTS - -9 n • Y i URBANC0 DESIGN _ - - - � ' � L t • � - � URBAN DESIGN SOLAR y _ • � � - . � - :. - ., . , ` _ - PHONE: 530 345-0005 . -'sola SolarEdge Power Optimizer LICENSE NO. 893826 B C-46 CONFIDENTIAL: THE INFORMATION CONTAINED i y `• Module Add -On for North America _+� +. Solar _ * IN THIS DRAWING SET IS CONFIDENTIAL AND P320 / P400 / P405 t SHALL NOT BE DISCLOSED IN FULL OR IN PART ,-, TO ANYONE EXCEPT THOSE INVOLVED IN THE _ - DESIGN AND INSTALLATION OF THE PV SYSTEM .` SolarEdge Power Optimizer'. 20 P400 P405 P300 P31.!,0. REPRESENTED IN THIS PLAN. - (for 60 cell modules) (for high-power (for 72&96•cell (fm thin film L - -60•cell modules) modules) modules) ' ' - - Module Add -On For North America , L INPUT RatedlnputOCPower•'f 3DD 320 ) r + • + - . Absolute ... ...... VicIlt ...... Absolute MaximuminputVoltage ; 400 405 ........... `•• `�••••••` �`� W ....... ♦ Pno P320 P400 % P405 Voc at lowest tem erature I (.................... p........1......... ........................... .............:.....'I:.........................I........... 48 80 125 I.. Vdc ' NIP PTt�peietlfigflefige................I..................:'.-...046-......................I.........0 00 I a7.6 306..... ....................... ,,dQ..:. .. Maximum Short Circuit Current Isc !...) I 10 I....Adc..... Maximum DC Input Current........... �..... ...I............11..........I..........................le . 12.5 ...................... 5...........1.....00 I Adc ....12 Maximum Effiaency .....13.75.... ............................................... 99..5 .. .... �..� • 3:.: `, Wei hted Efficiency ......... ......................... ................................................ ......................... ............................. ................ ........... N w Q • , r . , , Overvoltage Category I c OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) (, (37 a - Maximum Output Current ...... ytpP................ ...... ... ...................... 15 ................................:...................... ........................... . Ad c , y Maximum Output Voltage I 60 I E I vac (> U ^ t ' .`OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) I � Q Safety Output Voltage per Power 1 �jJ = 0 s Optimizer Vdc ~ r• owx" t STANDARD COMPLIANCE EMC ......................'.............................IEC62109:1(class FCC P � artlS Class B IEC61000-6 IEC61000-6-3 II safety) UL1741...... 1............. alb r Q U 2%,vesre RatdY S' RHS f INSTALLATION SPECIFICATIONS I ....... :......... .......... Yes , I U3 r Maximum ............. A!lollowed System Voltage . 1000 w .4 r .� . ' Compatible invertersAll SolarEdge Single Phase and Three Phase inverters (530) 520-3249 ...................Vdc Dimensions (W If L x H) 8 x 152 x 27.5 128 x 152 x 35 / 128 x 152 x 48 / 1 / mm/in ` I Z .. ...... .... ............... .................... x.1. 5 x 5.97.x.1:3 7 5 x 5.97 x 1.89 5x770 �. y rI '. . T ' Weight (including rabies) .............. L........... .5.97 .................. ... / 1.708 930 / 2.05 1 930/ 2;05 • •. gr /.lb... CO ..- a •. • ......... _ _ Input Connector 1 ..........MC4 Compatible ,. �•...................................................................... ....... �' .� ... s, ' • . Outpu[ Wire Type /Connector 1 ............... ................ ............ .............. Double Insulated MC4 Compatible .. ' �,: , ... ; = Output Wire Length .................... I... Operatin Tem erature Ran e ............... ........ 0.95/3.0.. I... 1.2 / 3.9 ................... + 0- 85/ m m/ft r pp URban'Desi -n Solar Inc _ . x ...c , l;.....P..............&........... - 4 40-+186. C..... , b , Protection Rating g ....................... �............ ...... ..... IP68 � NEMA6P I • � ..... e - 2260 Park � e Y„ lati0 Re ve Humidity+ .............. +++Rated STC a of [Ae r Module ..................... -100 ... ..... •••. `•. •`•.. 1 _ "' ). - SIL co, CA 95928. powmacule. of [0.5% p power[a4nnceanowed. -..................... 345=0005.; f PV SYSTEM DESIGN USING ! A SOLAREDGE INVERTERi'i SINGLE PHASE THREE PHASE 208V THREE PHASE 480V Leeense,893.826 B, G46 •.�. Minimum String Le "° Optimizers) 8 .10 ., r k PV optimiiation'at he module -level - , w • Maximum String Length 18 , .......... ..... z6 .I. s ' + - power .• r , _ _ i a, ,. (Power Optimizers) is: so h > , — U to 25% more energy +'� " gY 4 + ........... �_. Maximum Power per String I .. + L........ 5250 +11 6000 12750" W '�tt - 3 f . I w ` + mc -C rn G a ` - • • - � - • . �. Superior (99.5%) _ - Parallel Strings of ength Different Lengths L _ Yes ~ L l ` •.• " or Orientations , ,................................. • � Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading ' - ............... +anf,+wtana,reammi.pans.+fmpwo/paoorpseoroTaoma+re,mne. ............................ ' .............I.:... +., ..... i • Flexible system design for maximum space_ utilizatiori , Fast installation with a single bolt �. F - - OPTMZR. DATASHEET Next generation maintenance with module -level momtoring -,. a -Module-level �` voltage shutdown for installer and firefighter safety . - - - 'USA GERMANY ITALY FRANCE JAPAN -. CHINA - ISRAEL AUSTRALIA Www.solaredge.us t " -�` •" w ` 4' vad-1.111 ofPROJECT , x N0:' GSD 20170926 70972 DRAWN BY: SCM - .. DATE: 9/26/2017 r - POWER OPTIMIZER DATASHEET ,• .. SCALE: NTS PV_1 O t SnapNrack snapnrack.com Solar Mounting Solutions II ,, 7 SnapNrack UL 2-7703 Fire Classifitation PHONE: 530 345-0005 LICENSE NO. 893826BC-46 February 2015 TAANINDED . NTHIS DDRAWING SETS CONFIDENTIAL SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE As of January 1st, 2015 many jurisdictions are now enforcing codes. based upon updates to .. DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED NTHIS PLAN. .the International Building Code (IBC) and UL Standards 1703 (modules) and 2703 (mount- ing systems). The language included in the 2012 IBC requires that the combination of roof mounted solar modules and racking components is to be considered a system (IBC Section - 1509.7.2). Additionally, it requires that this system shall meet or exceed the fire classifica- tion of the roof assembly. W The objective is to ensure that the LU Z }- N PV system does not adversely affect M M � fire rating of the roof. Roof sur- c M C/) face fire ratings are classified either W Q w C� U A, B, or C; Class A being the mostLU Q resistant to the spread of flame. Q I— UO Since the physical characteristics of oD Q o U the PV module (material, thickness ' +rr ,a� ; ;,��� 3 �� cJ3 of glass, etc) also potentially af- fect how a fire will. act, modules are , „ � 49 now tested and assigned a "type" "` Z based upon these characteristics and spread of flame test results. There are 15 total module types, Types 1, 2 and 3 represent dif- CONTRACTOR OF RECORD ferences in the module composition and Types 4 - 15 are the same module compositions as - Types 1 - 3 with differing fire test performance. Urban Design Solar, c: Attachment 1 is the SnapNrack QNS File which is accessed through the UL Online Certifica- tion Directory, or available here: SnaDNrack GUMS File. The full SnapNrack Series 100 UL Test Report is available by sending requests to - appeng@snapnrack.com. :.. CLASS AFIRE .RATING PROJECT NO: GSD 20170926 70972 DRAWN BY: SCM Resources snapnrack.com/resources Design snapnrack.com/configurator Where to Buy snapnrack.com/where-to-buy DATE: 912612017 877-732-2860 www.snapnrack.com �'. contact@snapnrack.com 1 CLASS A FIRE RATING DATASHEET V-11 .SCALE:: NTS PV 1. 1 . ' - _. - • M ° . , - , . _ • , _ � " _ ' ' t URBAN 1 DE516N ,.r 775 Fiero Lane Suite 200 ¢ :, ,; SOLAR - 17, Sna p"Nrack, San Luis Obispo, CA 93401 , ~ F. • Email: contact@snapnrack.com - { _, - » .. - URBAN DESIGN SOLAR l'•(HOII 1t1h `$04tl *ns Phone Number: (877) 732-2860 PHONE: 530 345 0005 •� r - z LICENSE NO. 893826 R C-46 CONFIDENTIAL: THE INFORMATION.CONTAINED . + f, - , • IN THIS DRAWING SET IS CONFIDENTI • •' t . 4: �� �� '• .. , -• r ,, _ � , .,,.-- ,�'* AL AND SHALL NOT BE DISCLOSED IN FULL OR I N PART• ,. - , ;� �" . • -'�; TO ANYONE EXCEPT THOSE INVOLVED IN THE SnaUNrack Serres 100 Roof MountingJVS^elii F >' DESIGN AND INSTALLATION OF THE PV SYSTEM .a fir , , e s N REPRESENTED IN THIS PLAN. COVER LETTER . • Y . __ "` . •_ _ - , `The loading criteria used in this report is from ASCE 7-10. For codes that reference ASCE 7-05, Appendix A is ci w _ _ , - � - •- ' - . � U provided to convert the wind speeds in ASCE 7-05 to the wind speeds used in this report. Instructions for this . 'LLj oo conversion are provided in Appendix A. This report covers wind speeds (V„ h) to 190 MPH, ground snow to 120ULI i ULI Q � PSF, building heights to 60 feet, and tilt angles to 60 degrees. �" �: _ w U fn M _. - WQ The following codes are covered in this report: WJ Q LU (D U 6 IBC 2015 Lij _ • IBC 2012 t w , . .. Q cp U ` • IBC 2009 r , v • IBC 2006 - } _ Y s Q V • 2013 California Building Code (CBC) { • 2016 California Building Code (CBC) W (530) 520-3249 The mounting system structural submittal package shall consist of the following: • Pages 1-17 of the report (this includes this cover letter) ' _ CONTRACTOR OF RECORD • Applicable Pages from the following: o C1- C15 for 0 to 30 ft. Mean Roof Height and 6063 alloy rail - r UPbaci Desi 'II War,- o C17 — C32 for 31 to 60 ft. Mean Roof Height and 6063 alloy rail g P- -,.o- C33 —C48 for 0 to 30 ft. Mean Roof Height and 6005 alto rail _* 2260 Park A�euue+ ?' r g Y } 5 - Chico :CA 95928 _ o C49 . C64 for 31 to 60 ft. Mean Roof Height and 6005 alloy rail • Appendix A (if applicable) The applicable installation details + (listed on page 17,of this report) r e 1 '1 16! .= This report provides structural: engineering calculations and installation criteria for the mounhn s stem onl -it g y only, .does not certify the capacity of the ' , `' * .. fY p ty supporting members. The capacity of the supporting structure is to be cern- . `.Y �' • `:•*" �. •. 't _ • ;. �. :� 5�.,.-,rn c,..,e;�,;: ;k fled by the licensed professional responsible for. the building's structural certification.. ' f p (77) .732-2860 garding thi � report. . , Please contact Sna Nrack at 8'- or Contact@snapnrack.com, for questions re s • � •'ti n - FESS/p _ ENGINEERING LETTER _ No. 2567 :Exp. 12/31/17 PROJECT N0: GSD -20170926-70972 s Y`•. DRAWN BY: SCM CT11RA ��Psna q� OF cA��tA� '�` • DATE: 9/26/2017 • • . ". � ' - .`JAAI•`18 017 , , 'w a - .''._ - • ° . � - � " s t 2 1 'ENGINEERING LETTER RACKING ' •' ' p, .. ` V 12 SCALE: NTS �PV-d 2' • "'"^ "SSEMBLY MODULE . FRAME RAIL r NOTE: 1. ADJUSTABLE END CLAMPS USE SAME BONDING PIN DESIGN TO BOND MODULES TO RAIL 6-12 AWG BARE 5/16"-18 SS BOLT - COPPER WIRE SS SPLIT LOCK WASHER — (TORQUE TO 16 FT -LBS) SNAPNRACK VGROUNDLUG CHANNELNUT NDING RAIL PINS. NOTE: -1. ALL HARDWARE IS INCLUDED FROM MANUFACTURER 2. A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY CONTINUOUS ROW OF MODULES 3. GROUND LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL ASSEMBLER: 4. GROUND LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL OR PERPENDICULAR TO RAIL 5. ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER WIRE INSPECTOR: DESCRIPTION: DRAWN BY: MIKE WATKINS SNAPNRACK MOUNTING SYSTEM APPROVED BY: I CODY NORMAN REVISION: LI`' GROUNDING DETAILS G 1/11/2016 NEW ITEM Solar Mounting Solutions Sunrun South LLC 595 MARKET STREET, 29TH FLOOR. SAN FRANCISCO, CA 94195 USA PART NUMBER: SCALE: = i RHONE (415)550.M. FAX(a15)55D.M DNS _.KwwiH��Y���FmE�N,REAA.. RFPROIKICl10N, OISClO5U1F.OR USE Tl@REOF 6 PAO"B"Ep 1V1110U! T"E NWRE.Y f,W9FNi OF SUNRUNSWiH LLC URBANMi DESIGN SOLAR F' - URBAN DESIGN SOLAR PHONE: 530 345-0005 LICENSE NO. 893826 B C-46 CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART ' TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. ai ILU 00 w w Q c/) L U Q C)�_ V L U ¢ [] C5 _ W(530)520-3249 . Z CONTRACTOR OF RECORD [Jrban Design. Sotar, Inc 7:12-60 Park Avenue_ .CFiico,.GA 95928' �. (30} 345-0005 License,#893826 9,1]46 T } GROUNDING DETAILS VKUJLG I NU: 650-20170926 DRAWN BY: SCM DATE: 9/2612017 1 GROUNDING DETAILS V V-13 .SCALE:. NTS -13 1 I SS BONDING PIN "'"^ "SSEMBLY MODULE . FRAME RAIL r NOTE: 1. ADJUSTABLE END CLAMPS USE SAME BONDING PIN DESIGN TO BOND MODULES TO RAIL 6-12 AWG BARE 5/16"-18 SS BOLT - COPPER WIRE SS SPLIT LOCK WASHER — (TORQUE TO 16 FT -LBS) SNAPNRACK VGROUNDLUG CHANNELNUT NDING RAIL PINS. NOTE: -1. ALL HARDWARE IS INCLUDED FROM MANUFACTURER 2. A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY CONTINUOUS ROW OF MODULES 3. GROUND LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL ASSEMBLER: 4. GROUND LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL OR PERPENDICULAR TO RAIL 5. ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER WIRE INSPECTOR: DESCRIPTION: DRAWN BY: MIKE WATKINS SNAPNRACK MOUNTING SYSTEM APPROVED BY: I CODY NORMAN REVISION: LI`' GROUNDING DETAILS G 1/11/2016 NEW ITEM Solar Mounting Solutions Sunrun South LLC 595 MARKET STREET, 29TH FLOOR. SAN FRANCISCO, CA 94195 USA PART NUMBER: SCALE: = i RHONE (415)550.M. FAX(a15)55D.M DNS _.KwwiH��Y���FmE�N,REAA.. RFPROIKICl10N, OISClO5U1F.OR USE Tl@REOF 6 PAO"B"Ep 1V1110U! T"E NWRE.Y f,W9FNi OF SUNRUNSWiH LLC URBANMi DESIGN SOLAR F' - URBAN DESIGN SOLAR PHONE: 530 345-0005 LICENSE NO. 893826 B C-46 CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART ' TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. ai ILU 00 w w Q c/) L U Q C)�_ V L U ¢ [] C5 _ W(530)520-3249 . Z CONTRACTOR OF RECORD [Jrban Design. Sotar, Inc 7:12-60 Park Avenue_ .CFiico,.GA 95928' �. (30} 345-0005 License,#893826 9,1]46 T } GROUNDING DETAILS VKUJLG I NU: 650-20170926 DRAWN BY: SCM DATE: 9/2612017 1 GROUNDING DETAILS V V-13 .SCALE:. NTS -13 URBANC!bDESIGN SOLAR am Us ftlta t1 c01WI-11 wt 6 rftirirr � a r r►,r�. ! I: URBAN DESIGN SOLAR PHONE: 530 345-0005 LICENSE NO. 893826 B C-06 lurk -20.2014- l?a�* ftopw Ido. i al rOwcf ua 1 F'roJ�ct Na, [i101 703. MI. 68Bai7�113g1e�! i Eltzr f0t''0C39si�CfT-G1 dut{e 20�'; 2014 CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART (41f. I�ir' T 1h �3i Ph +BT.t 8. 57' 20 ; lot 7arrRli�ldpta9 Ltd2nt$Et.gL�ne�gorrr 6 tfiti�Flasr ah i HOD �HI<RON, ISRAEL �-Ab'ime o 5E9.KUS / S' M0 tUS / SEZ0XUS wv en the Sol ga e9pld strotdovvi► wh# bte 13beEed"CF�Ii irzfoac • )e w" Is pir 0 Wi &W04�t3� k ii installat in I�v�rrtrcr Saf�fjr 3�vitr 'v hc�ra xlaeaia>Hi is driy liumber,'i►w�rtler F�rt,number may tie fnllovr4�j by a suFjia TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. ¢ul)40vt En eldudiion at S Or Efta Pmduct� toMC Rapdd.5ti� Roqu mmaf 6aer`Mr. Mulr i�asl;• Thw lrr r t3ria. ttr�Aliso? e t rArrltstatl req►drametrte �rrlafn d do IYre:fallprilrs m itre llitofwawm Coo,i0 1 Ss F. X4112 rnoes¢w: fur Title IrtV s3 ill via c+u*anti OY 610"a-l?uato # 41 dim$ 03 07014, RSipid shUtd[st A t&A ware �i6lfWTT,tyF$ J�0�13gl�Scydy�pe{;T6a�9t�1)4&& Ltd, O Mlik sO 81 t{CD FIASFIAI ON, ISRAF,cL".end tt7I nm by I"itfilt •.. - Thoovalunllaa fru rt Unna awrziligft ig op km and rowan s Wth pari numbam listed bei .. - ►€ 2t� l� u+ i�d rl lirr�il :a, +9rar* aierda.+r1t00 mpsysEhln (fastoY►�ati>rltlutrdonanl5ltan: i' 'This IisiPae; etri. srn #Mf b �ordcn of a* e�lue i 0A,60verad:by InWxtak Int ad N0610M;554. 0 k1'ora ora. y qUs t`ons.r> (r1g the amrtatre0d qn tlils rti3M �.nrEy ., iR 'Other tvF�ea aitt l i ' t� vl naQ t�alto rte unnnsl. Plsas� :'•iiia Lir Report does not ps€cyr�t ofi Gon iEia u.o �f qty h�iari�k,caiefkaUon mm'im. CCierpldtod by � e FtdvtC+WU6 by hfw," Lice 1,YIri�, Gln ;T�m Lead Tlil §1af3 inner � I[�wq��_ � g J � � �/�-'.� .�f4,�ll�tflf�li i �x. '�' j a�l�fla;lj7r4`3 oar' ;�u .201+9 I r ra:. ,a Juno , 2014 � rn w ( j �– (/� � LU¢ Q9 W U co Z >_ CV w < M M � — C> CJ) LL Q w U) Li � Q � O O = C/3 • P�r`srop3Trrr]r�rs: d pt j�wu Where= I any numhtTj ", qpWf amaKitnumvalue v42re-xiw 9SD,,yyy could be ACO orTFI; anti tarx Ls %ny CornbfnatloA of four tatters mid numbers, LU z (530) 520-3249 a MXXX- -b.• ONVOR ". 09-=4, OP -M -EV; whoa =Is any cumber; 4.9: •o Pan, p6hb, RRdd,. Pae2s ur�[e eaa, mc; ddQ, use Ca aTyy ruimber,0�9�o a rrm�mrrnl ilpto womWA M&OW=!mS 1), ddd­W0,.eaae=M. CONTRACTOR OF RECORD o tom, Pyyy, PEa, prrrr{tip, Penn,;nd Paco; where wa4,,Wy,_w Is wW rium*, 0 -9 -to a mmd.mum Urban Design Solar, Inc up to* wzODO,yyyr35�,> f�wWamramin(is nnr6aooItiirryrwmtknr,0.9wanrml,numupca. 26UPark Avenue Chico,.CA 95928' ■: fi Irn�rters: 'a 5E331!)OibitS i SQA=IJS f, SE59�lI.US / SF�C►it%A-41f� / SET60�4�iX�i J 9E3.DOlt�F1U5, f SSi1490ANihS where i9m Sobr rA-Ad:zhutdown cable labeled "MiaLd �uvmdtxelwhish H part 030)'345-WOS License #893826 B, C-46 -of IdtSfU*0-;d0sInskzihdintalo1mmr.W'-$detVSWItchwhervmoaarxxisagynunther; [wener. Part number maybe 4allwm!d by a suft: Seo.,.., rn cc,.a,,� TRrepelbin l�i_eellda;aa�6+�fi!lM MW "Kit rMs Crew Jetr}r tiislexmfaei&lawr?a�w,ift h�"18ft�rtY��b�sd6SA�i{��aes3fLl4Zn:lsns. dU 1�. Q' tlld �i b r�IVUpc4�ll�A Cf�Yf� r15 r2p0iS � 1.3f RaiM1.�'W yip 9t'F�1` 11�'tR�0111'd l�l►:�C'.ItsCyY �e�b Q4 =0=0W� OKI Wn9,�e,ma 4q,���lowx,� td?yc miv�w, vua:+ aw �baa� warty rruew �not;Ras rmiw 015- 1st," tztsc+Y tuna' s Spee i I'CeAiOtoiF1� �>� 17h�t tt�ittfcoJ fietlae+>u►'p p e.raa. RAPID SHUTDOWN G�ola(iTeaSrp4unimilA,ll aatgs;{11d1tRa}4 i�v . PROJECT NO: GSD -20170926-70972 DRAWN BY: SCM DATE: 912612017 1 RAPID SHUTDOWN DATASHEET V-14 SCALE: NTS PV -14 URBANMDE5161V FMT N SOLAR Powering Business Worldwide pe.eaton.com URBAN DESIGN SOLAR PHONE: 530 345-0005 LICENSE NO. 893826 B C46 CONFIDENTIAL: THE INFORMATION CONTAINED _-9-�--- IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART a TO ANYONE EXCEPT THOSE INVOLVED IN THE k DESIGN AND INSTALLATION OF THE PV SYSTEM #�.rr General Duty Cartridge Fuse , REPRESENTED IN THIS PLAN. Safety Switch DG222NR6 UPC:782113144221 ' rn LU Dimensions: U 00 • Height: 7 IN LU W Q • Length: 6.41 IN c3 3 rn • Width: 8.4 IN Q � LU U Weight:9 LB LU Q ~ Notes:Maximum hp ratings apply only when dual F= , Q 00 O element fuses are used. 3-Phase hp rating shown is ID U a grounded B phase rating, UL listed. Warranties: • Eaton Selling Policy 25-000, one (1) year from z (530) 520-3249 the date of installation of the Product or eighteen (18) months from the date of shipment CONTRACTOR OF RECORD of the Product,'whichever occurs first. Specifications: Urban Design Solar, Inc: • Type: General Duty/Cartridge Fuse 2260 Park Aveadu,6 .. -Amperage Rating: 60A :Chico, CA 9502- 592• -Enclosure: NEMA 3R 0141.5-`6.00S • Enclosure Material: Painted galvanized steel lAcense:#893826 B, ­46- 46• - Fuse Class Provision: Class H fuses Fuse Configuration: Fusible with neutral . Number Of Poles: Two-pole • Number Of Wires: Three-wire • Product Category: General Duty Safety Switch t • Voltage Rating: 240V AC DISCONNECI Supporting documents: • Eatons Volume 2-Commercial Distribution • Eaton Specification Sheet - DG222NRB ` Certifications: • UL Listed PROJECT NO: GSD-20170926-70972 DRAWN BY: SCM DATE: 9/26/2017 PV-1 5 ` 1 AC DISCONNECT DATASHEET . V-15 SCALE: NTS