Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B17-2301 043-430-002
1 r BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) :536.538.4365 (Cut off time for inspections is 3pm) Development Services cannot ivarantee inspections on the date requested Office: 530.538.7601 Fax: 530.538.7785 %vevw.l3utteCountv.net/dds Permit No: B 17-2301 Issued: 9/27/2017 APN: 043-430-002 Address: 784 WOODBRIDGE DR, CHICO Owner: MCKELLAR WILLIAM J & GINA M. Permit Type: SOLAR ROOF -RES Description: Install new 5.8k W PV roof mounted solar syst AREA 5 L Flood Zone: None SRA Area: No Front: Centerline of Road: Rear: SRA: Street: AG: Interior Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING Inspection Tyne IVR INSP DATE Setbacks 131 Foundations / Footings 111 Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Sign d Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing. 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under.Slab Plumbing 411 Blockin Under inin 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed Shearwall/B.W.P.-Interior 134 Shearwall/B.W.P.-Exterior 135 . Roof Na i I/Drag Trusses 129 ' Manometer Test 605 Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed Permit Final 802 1C.1 1 Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test or Final 702 Swimming Pools Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Swimming Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 503 Pre -Plaster 507 Manufactured Homes Setbacks 131 Blockin Under inin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Skirtin /Ste s/Landin s 610 Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: Length x Width: Insignia: Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final xxPROJECT FINAL - rrujeci rnrn is a c.eruncaie ui occupancy for tKesmenuai only) PERMITS BECOME NULL AND VOID I YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS CONIiNIENCED, YOU iNIAY PAY FOR A I YEAR ;,RENEWAL 30 DAYS PRIOR TO EXPIRATION t V': X SERIES Optimize System and Installation Efficiency SunPower®.AC Modules, which include a factory -integrated SunPower microinverter, provide a revolutionary combiriation.of high efficiency, high. reliability, and module-, evel DC to ACpower conversion. Designed -specifically for use.with.SunPower InvisiMountTM! and the SunPower Monitoring System, SunPower AC Modules enable rapid installation, best -in -class system aesthetics, and intuitive visibility into system performance. All this comes with the best Combined Power and Product Warranty in the industry. sunpower.com 11-lighest of over 3,200 silicon solar panels, Photon Module Survey, Feb. 2014 2#1 rank in "PV Module Durability Initiative Public Report," Fraunhofer CSE, Feb 2013. Five out of the top eight largest manufacturers were tested. Campeau, Z. et al. "SunPower Module Degradation Rate," SunPow6r white paper, Feb 2013. See www.sunpower.com/facts for details. 'Standard Test Conditions (1000 W/ml irradiance, NIA 1.5,25* C) NREL calibration standard: SOMS current, LACCS FF and voltage. All DC voltage is fully contained within the module. 'Based on average of measured power values during production. See www.sunpower.com/facts for more reference information. . •, For more details, see extended datasheec ,Nwwsunpower.fom/datasheets. - o Output @ 240 V (min./nom./max.) SPR -X21 -345{ -AC SPR -X21 -335{ -AC . Nominal Power 3(Pnom) 345 W 335 W Power Tolerance +5/70% '.+5/-0% Avg. Panel Efficiency' 21.5% 21.b% Temp. Coef. (Power)-0.29%/OC 1_.33 A Shade Tolerance Three bypass diodes Integrated module -level maximum power point tracking 11-lighest of over 3,200 silicon solar panels, Photon Module Survey, Feb. 2014 2#1 rank in "PV Module Durability Initiative Public Report," Fraunhofer CSE, Feb 2013. Five out of the top eight largest manufacturers were tested. Campeau, Z. et al. "SunPower Module Degradation Rate," SunPow6r white paper, Feb 2013. See www.sunpower.com/facts for details. 'Standard Test Conditions (1000 W/ml irradiance, NIA 1.5,25* C) NREL calibration standard: SOMS current, LACCS FF and voltage. All DC voltage is fully contained within the module. 'Based on average of measured power values during production. See www.sunpower.com/facts for more reference information. . •, For more details, see extended datasheec ,Nwwsunpower.fom/datasheets. FIM Output @ 240 V (min./nom./max.) 211/240/264 V Output @ 208 V (min./nom./max.) J83/208/229V: Operating Frequency (min./nom./max.) . 59.3/60.0/60.5 Hz Output Power Factor (min.) 0.99 At Max., Continuous Output Current @ 240 V 1_.33 A AC Max. Continuous Output Current @ 208 V 1.54 A AC Max. Cont. Output Power 320 W DC/AC CEC Conversion Efficiency 96.0% Max. Units Per 20 A Branch Circuit @ 240 V 12 (single phase) ' Max. Units Per 20 A Branch Circuit @ 208 V , 10 (two pole) No active phase balancing for 3 phase installations 11-lighest of over 3,200 silicon solar panels, Photon Module Survey, Feb. 2014 2#1 rank in "PV Module Durability Initiative Public Report," Fraunhofer CSE, Feb 2013. Five out of the top eight largest manufacturers were tested. Campeau, Z. et al. "SunPower Module Degradation Rate," SunPow6r white paper, Feb 2013. See www.sunpower.com/facts for details. 'Standard Test Conditions (1000 W/ml irradiance, NIA 1.5,25* C) NREL calibration standard: SOMS current, LACCS FF and voltage. All DC voltage is fully contained within the module. 'Based on average of measured power values during production. See www.sunpower.com/facts for more reference information. . •, For more details, see extended datasheec ,Nwwsunpower.fom/datasheets. FIM Solar Cells • 96 Moncicrystalline Maxeon Gen III - Front Glass High -transmission tempered glass with Temp. anti -reflective coating: - Environmental Rating Outdoor rated Frame Class 1 black anodized (highest HAMA Impact Resistance , rating), , Weight 45.5 lbs (20.6 kg) `. Max. Recommended Module Spacing 1.3 in. (33 mm) 11-lighest of over 3,200 silicon solar panels, Photon Module Survey, Feb. 2014 2#1 rank in "PV Module Durability Initiative Public Report," Fraunhofer CSE, Feb 2013. Five out of the top eight largest manufacturers were tested. Campeau, Z. et al. "SunPower Module Degradation Rate," SunPow6r white paper, Feb 2013. See www.sunpower.com/facts for details. 'Standard Test Conditions (1000 W/ml irradiance, NIA 1.5,25* C) NREL calibration standard: SOMS current, LACCS FF and voltage. All DC voltage is fully contained within the module. 'Based on average of measured power values during production. See www.sunpower.com/facts for more reference information. . •, For more details, see extended datasheec ,Nwwsunpower.fom/datasheets. shmamiam- 01FREM Warranties 25 -year limited power warranty • •, 25 ear limited product warranty UL listed to UL 1741; including: IEEE1547/1547a and IEEE1547.1/1547.1a Utility " Interactive PV Rapid Shutdown Equipment Equipment Grounding UL 6703, UL 9703 Connectors and cables (load break disconnection) UL 1703 PV.Modules (Type 2 fire rating) Certifications Enables installation in accordance with: -- NEC 690.6 NEC 690.12 Rapid Shutdown (inside and outside the array) :. NEC 690.15 AC Connectors, 690.33(A)=•(E)(1) FCC and ICES -003 Class B When•used with InvisiMouni reeking (UL 2703) Integrated grounding and bonding Class A fire rated ' PID Test "Potential -induced degradation free . f :. 280 mm [11.02 in] 1107 mm EJL _ (43.6 In] t�mm a 1 [41.2 in] , 1558 mm I • , - • . Is.[61.3 in] Please read the safety and installation Instructions for details. Document # 5152[ 5 Rev D /LTR US Operating Temp. -40° F to +185° F (-40' C to +85° Q Max. Ambient 1226 F (50° Q Temp. Max. Load Wind: 62'psf, 3000 Pa, 305 kg/m? front & back Snow: 125 psf, 6000 Pa, 611 /m2 front Impact Resistance , 1,inCh (25 mm) diameter hail'ai 52 mph (23 . :. mis) _ shmamiam- 01FREM Warranties 25 -year limited power warranty • •, 25 ear limited product warranty UL listed to UL 1741; including: IEEE1547/1547a and IEEE1547.1/1547.1a Utility " Interactive PV Rapid Shutdown Equipment Equipment Grounding UL 6703, UL 9703 Connectors and cables (load break disconnection) UL 1703 PV.Modules (Type 2 fire rating) Certifications Enables installation in accordance with: -- NEC 690.6 NEC 690.12 Rapid Shutdown (inside and outside the array) :. NEC 690.15 AC Connectors, 690.33(A)=•(E)(1) FCC and ICES -003 Class B When•used with InvisiMouni reeking (UL 2703) Integrated grounding and bonding Class A fire rated ' PID Test "Potential -induced degradation free . f :. 280 mm [11.02 in] 1107 mm EJL _ (43.6 In] t�mm a 1 [41.2 in] , 1558 mm I • , - • . Is.[61.3 in] Please read the safety and installation Instructions for details. Document # 5152[ 5 Rev D /LTR US Simple and Fast Installation " Integrated module to rail grounding a r° f t F ; w s .:: r _= ..�. s n 5• t y y f ;%{� M ° "�. wi . Pre assembled . ' Levitating",mid clamp for easy placement � � �; � t � Mid clamp widq add tater even r _ r module - Simple re tlnlled-rail splice - P UL 276ibi ted integrated_grounding ;. x y .y 3� ;FleXible Design Addresses nearlyall sloped residential Design inaandscape and portrait f Rads enable easy9bstacle;rnanagement `:" ate. Customer -Preferred Aesthetics R z� 4 #1 module and #1 mounting aesthetics 3 � , z R "� 7c � .. � • sy Best' m class system aestheticsy a,. 3F Elegant Simplicity Premium low profile design r' �' Black anodizedcomponenis y :.:: SunPower® InvisiMountTM' is.a SunPower-designed s ,ce- y...,.t y r .. .. .. Hidden mid clamps and end clamps rail -based mounting system. The Invisi.Mount system hardware :and cappetl flush rails - z addresses residential sloped roofs and combines faster Part of Supe�or System g ti #b 3 s �4 installation time,:design flexibility,: and superior aesthetics. �. Biult for use with SunPower DC and AC 6n dulesf, " The InvisiMountproduct was specifically envisioned and Best in dass�systemreliability and aesthetics ;Combine with SunPower modules ander*° 'x Y k engineered to pair with SunPower modules: The resulting monrtonrg app t a F, system -level approach will amplify the:aesthetic and installation benefits for. both homeowners and installers. sunpower.com " a; U Module* / Mid Clamp and Rail Module* / End Clamp and Rail .r•s ysY _ A, Rail& Rail Splice Ground Lug Assembly End Cap ,Component Material. Weight, Mid Clamp ' Black oxide stainless steel AISI 304 63g( . 2. . 2 oz) End Clamp Black anodized aluminum alloy 6063-T6 110 g (3.88 oz) Rail . Back anodized aluminum alloy 6005-T6 830 g/m (9 oz/ft) Rail Splice Aluminum alloy6005-T..5. ' 830 g/m (9 oz/ft) Ground Lug Assembly(A2-70 304 stainless ; ' - bolt, tin-plated copper lug). 106.5 g/m (3.75 oz) End Cap . Black•acetal (POM) copolymer' 10.4 g (0.37 oz) Temperature -40° C to 90° C (-40° F to 194' Fj Mak Load • 2400 Pa uplift. • 5400 Pa downforce A . Wa"rrarities 25 -year product warranty 5 -year finish warranty UL 2703 Listed t Certifications Class Afire rating when distance between roof surface and bottom of SunPower module frame is <- 3.5" ' Composition Shingle Rafter Attachment Application Composition Shingle Roof Decking Attachment ' • • Curved and Flat Tile Roof Attachment Universal Interface for Other Roof Attachments Refer to roof attachment hardware manufacturers: documentation *Module frame that is compatible with the InvisiMount system required for hardware interoperability. O 2015:SuOower Corporation. All Rights Reserved. SUNPOW ER, the SUNPOWER logo, and INVISIMOUNT are trademarks or registered - trademarks of Sun Power Corporation. All other trademarks are the property of their respective owners. sunpower.com Specifications included in this datasheet are subject to change without notice. : _ Document #509506 Rev B 9UHPI22) -. o r1 v ��5�.. hMiy Y �•.... ImproveSupport,', r SunPower Monitoring Solution, Reduce"Maintenance Cost's t- Plug and Play Installation . � Y s An rntuitive lomonitoringwebsiteenabeThis coin f.ete solution forresidential monitoring includes the ' SunPower® PV Sgpervisor 5X (PVSSx) which improves the installation See a visual map of homeowner sites r f c process, overall system reliability,.and customer experience.. Remotelymanagehuntlreds of sites Receive electwe system reports Compact footprint for improved aesthetics Locate system issues and remoteldiagnose Robust cloud connectivity and comprehensive local connectivit yy Diagnose issues online Flexible configuration of devices during installation . a * Consumption monitoring �y� Dnll down for the.status of individual Revenue -grade production monitoring } r e =-g Web -based commissioning app Remotediagnostics of PVS5x and inverters ' 5,. yin - �1y�-M. ar`� Durable NEMA 3R enclosure reduces maintenance costs 3a.x W a Cloud Connectivityoust _ Add Value for Homeowners x Multiple. Options to maintain optimal i.With the SunPower Monitonng System F v 5� connectivity: * horneownecs can b , a Hardwired :Ether'net �Se�e �whattheir solar system produces each "' � - day month oryear t`. Power Line Communication (PLq } Optimize their solar investment and save on" j W-Fi B ever ex Fenses' h u gY P Celluiarbackup s { See their'energy use and estimated bill savmgs� � a f ySee their solar system s performance using theme a SunPower`, itorrng website or mobile °^"� s • e , .a.� '."L Y �r 111} AV2 •� ,- ~ _,&� it - s —_ - Supports Su •es pp Multiple P Inverter YP. Supports SunPower 96 -cell AC module systems; DC.string inverter systems, Y and hybrid (DC and AC) systems. aate, g d T — T }•.. tM.r.,nY, ;:i :e1tiY ._ +'!",, - a`i s ■ SunPower Monitoring Website PVS5x fl i�YYSt1 _ t,== Multiple communication options include Ethernet, 7r__r=_ PLC, Wi-Fi, and cellular .; ' ftIftfiougme Compatible SunPower AC Modules SunPower 96 cell AC Modules (85) (number supported per PVS5x) Partner Website Compatible String Inverters (number supported per PVS5x) Fronius (10), SMA (10), ABB (30) InternetAccess High-speed Internet access Phone®, iPad°, and AndroidTm Accessible router or switch Power 240 VAC, 50 or 60 Hz Weight 2.5 kg (5.5 lbs) Dimensions 34.5 cm x 20.6 cm x 9.3 cm (13.6 in x 8.1 in x 3.6 in) Enclosure Rating Type 3R Document 4513829 Rev A Supports SunPower 96 -cell AC modules, DC string inverters, and hybrid (DC and AC) systems SunPower AC Modules O • • Temperature-30°Cto+60°C(-22°Fto+140°F) Humidity (maximum) 95%, non condensing RS -485 Homeowner Website monitor ussunnower com Partner Website sunpowermonitorcom/partner Browsers Firefox, Safari, Chrome, Internet Explorer Mobile Devices Phone®, iPad°, and AndroidTm Homeowner App 1. Create account online at monitor us cunoowercom. 2. On a mobile device, download the SunPower Monitoring app from Apple App Store'" or Google Play" store. 3. Sign in using account email and password. Document 4513829 Rev A Supports SunPower 96 -cell AC modules, DC string inverters, and hybrid (DC and AC) systems SunPower AC Modules O • • Temperature-30°Cto+60°C(-22°Fto+140°F) Humidity (maximum) 95%, non condensing Warranty 10 -year Limited Warranty Certifications UL, CUL. EN60950, EN61326-1 F C c&us UMD FCC ID: YAW513402 ITE: E477122 •711:��K�/1�4,���+�4�Yt��L�.t11�$�t?t�ySC�R�:�l��.d� � M U V P 1�G° tia�ivin �zrepn®cx� raievc�rt c$ur+u�tv�erf.njr� �rctjz c a�+m=>� - • . � • ,Q��n��:t� �.>_��;.>�Ict.����t�s RS -485 Inverters and meters PLC for 96 -cell AC modules Integrated Metering One channel of revenue -grade production metering (ANSI C12.20 Class 0.5) and two channels of net metering Ethernet WAN and LAN ports PLC Integrated HomePlug AV standard communication to PLC devices over AC wiring Wi-Fi 802.11b/g/n Cellular 3G UMTS ZigBee Home automation, inverter communications, meter readings USB Type A Supports additional communications up to 0.5 Amps (for example, Wi-R, Bluetooth. ) Memory 2 GB flash 1 GB RAM Data Storage 60 days Upgrades Automatic firmware upgrades Warranty 10 -year Limited Warranty Certifications UL, CUL. EN60950, EN61326-1 F C c&us UMD FCC ID: YAW513402 ITE: E477122 •711:��K�/1�4,���+�4�Yt��L�.t11�$�t?t�ySC�R�:�l��.d� � M U V P 1�G° tia�ivin �zrepn®cx� raievc�rt c$ur+u�tv�erf.njr� �rctjz c a�+m=>� - • . � • ,Q��n��:t� �.>_��;.>�Ict.����t�s Prot'e a versatile W—a ket'M is iB Tr-t that VI to most roof profiles. ,Each ProteaBracket'-comes with a factory- applied, _ P r. otea B rac ketTm adhesive rubber sealant'on the base. A structural A2 tstalnle'sssteel bimetal attachment bracket, ProteaBracket s`zompatiblewith most common metal roofing materials 2'27 (57.66 mm) \ 111 'All f6dr,ore-punched holes must be used to achieve * s 400 Tested:strength. Mounting hardware Is furnished with the t' ( s. o mm) 1, ProteaBracket.-For design assistance, ask,your distributor,' .F, L__���,r =.or visit www.S-5.com for'the Iridependent lab test ata _. that can l e used for load -critical "designs, and applications.0.33" . (8.38 mm) Also, please -visit our website formore information including -metal lurgical.compatibilities and specifications S-~Si®holding strength is unmatched in the industry ", y r r by c : `2. Multiple Attachment<� , f,(si;: Options • r ♦♦ k e Factory Applh Slde'RallOption -�1 4aY sealant i 0.97". (24.64 mm) 0.33" (8.38 mm) Th ru Hole 4x 0.27"/6.86 mm � 0.39" c'1 (9.91 mm) M 3.93" (99.82 mm) Please note: All measurements are rounded to the second decimal place. a x; Example Applications 3R< d • *ya ', �? � 3 {_•' Y *dam-'. S =�. •� E,Top;Rail"Option ' � �`ti �� �' S -S -PV. Kit demonstrated with a Protea Bracket on a trapezoidal profile. Example Profile. 5-51° Warningl Please use this product responsiblyl Distributed by Products are protected, by multiple U.S. and foreign patents. For published data regarding holding strength, bolt torque, patents, and trademarks, visit the S-51 website at www.S-S.com. Copyright2013, Metal Roof Innovation, Ltd.S-5! products are patent protected. ' S-51 aggressively protects its patents, trademarks,and copyrights. Version 112513. r This product must only be connected to 'a single-phase system (L -L) of a, premises with the neutral (N) bonded to ground at the service entrance per code. (The MI does not reference the N to ground internally, therefore this reference must be accomplished only at theservice entrance.) Ensure that the installation site has a high-quality N-to-groundreference at the service. The MI determines L -N voltages based on measuring internally from L to the MI chassis, which is connected to the EGC. 4..1. NEC Compliance and. the Ground_ Path The following are the grounding -related NEC Articles and applicability for SunPower AC Modules on rooftops, and are relevant when SunPower AC Modules are mounted on the InvisiMount system: • 690.41 does not apply to AC modules. 690.42.does not apply to AC modules • 690.43 covers equipment grounding, which is:the only required type of grounding for an. AC module. • 690.45 specifies that the EGC for PV Source and PV Output circuits be sized based on 250.122::Per.690.6, requirements in 690 pertaining to PV Source circuits shall not apply to AC modules because the circuits are internal to the Listed. AC module. The AC module output is considered an inverter output. Requirementsfrom 250 for equipment grounding,are applied from the service to thejunction: box. The Listed AC Module interconnecting cable system uses the product safety -listing standard which 'is based on. section 250:122.and other sections in 250. • 690.46 modifies 690.45 when the EGC is not protected within a raceway. This is not relevant to the AC Module system because the EGC is within the listed AC Module interconnecting cable system. -- • 690.47 does not apply to AC modules: ■ 690.47(A) does not apply when, installing an AC system. The AC "system",was already existing on the premises, and hence you are installing AC modules on the AC system. ...690.47(B) applies to DC systems; it does not apply to AC modules. ■ 690.47(C) does not apply (see 690.47(6)). ... ■ 690.47(D) only provides guidance for a "dc grounding electrode conductor:" . • 690.48 applies, but isn't relevant. • 690.49 does not apply. • 690:50 applies, but isn't relevant: Note as -well that Section 4.1.of the SunPower:AC Module Safety.and.Installation Instructions (#51744) explains; As a Listed product, "SunPower AC modules shall be installed and used in accordance with* any instructions included in the listing or labeling" (110.3(6)).. In.addition, SunPower AC Modules "shall be grounded using the integrated equipment grounding conductor ... no additional grounding conductor attachment to the AC module is required." Plante'' -, Bonding Components Wounding fleitk6de.to , ... - .. . 6"A7(A) — . . . in/a tt, rviceponel, '�"V( - 2 servIc"441 to lto;ftPjunctlon Box, ' Rooftop Junction % Box, to 141 ;690,43(3) 0703: .9703,. 4 AC Cable to 6/8 (0� art of V, 17 03 M croinveftei Llstl�� 1741 MI . I tro nyertcr.,to "tram Na (parto , f V03 . ti . AC Module e Usti n'M 74 i-. o 6. Cable to At Cable 690 43(3) .— __ �' . , - , `690:43(0) 1741 ';. , %- .6703 'AC 6".43 703 A 6dule':Fran e to fi 2703 M C am- to Ra 6".43(p) At Module Fia me- i o690 - A) ., .. — , ,, End Clamp to R6j1 496 .4*C,) 2703 .:690.43(0), 6" 9 Rai ft6 SP!i ce 4 IOA3( C) ,;690A3(C) 2703 A".43(0). "qu Componen[ Material I Weight Mid Clamp _ — ,.Black oxidesteinless steel AISI 364: .63 g Q.2.oz) End Clamp; • Black anodized aluminum alloy 6063 T6 110 g (3.88 oz),, Rail - Slack -,'anodized aluminum allby6005-T6 i. 830 g/m (9 oz/ft).,: Rail Splice','" Aluminum alloy 6005-T5" i,830 g/m (9 oz/ft) Ground Lug Assembly - '` 304 stainless (A2;70 bolt tin: plated copper lug) ; 106 5 g/m (3:75 oz) End Cap •- Black acetal (POM) copolymer- • . - 10.4 g (0:37 oz) Simple and Fast Installation Integrated module -to -rail grounding Pre -assembled mid and end clamps Levitating mid clamp for easy placement Mid clamp width facilitates even module spacing Simple, pre -drilled rail splice I UL 2703 Listed integrated grounding Flexible Design Addresses nearly all sloped residential roofs Design in landscape and portrait Rails enable easy obstacle management Customer -Preferred Aesthetics I #1 module and #1 mounting aesthetics i Best -in -class system aesthetics I Premium, low -profile design Black anodized components Hidden mid clamps and end clamps ! hardware, and capped, flush rails r Part of Superior System Built for use with SunPower DC and AC modules Best -in -class system reliability and aesthetics Combine with SunPower modules and monitoring app Elegant Simplicity SunPower° InvisiMountTM is a SunPower-designed rail -based mounting system. The InvisiMount system addresses residential sloped roofs and combines faster installation time, design flexibility, and superior aesthetics. The InvisiMount product was speci'ically envisioned and engineered to pair with SunPower modules. The resulting system -level approach will amplify the aesthetic and installation benefits for both homeowners and installers. iflilll ;�,;, sunpower.com 'Highest of over 3,200 silicon solar panels, Photon Module Survey, Feb. 2014 1 rank in "PV Module Durability Initiative Public Report,' Fraunhofer CSE, Feb 2013. Five out of th=_ top eight largest manufacturers were tested. Campeau, Z. et al. "Sunpower Module Degradation Rate," Sun?ower white paper, Feb 2013. See www.sunpower.com/facts for details. 'Standard Test Conditions (1000 w/ml irradiance. AM 1.5.25° Q. NREL calibration standard: SOMS current, !ACCS FF and voltage. All DC voltage is fully contained within the module. 'Eased on average of measured pourer values during production. See vrvwa.sunpower.com/facts for more reference information. For more details, see extended datasheet: www.sunpower.com/datasheets. Operating Temp. -40° F to +185° F (-40° C to -85' C) Max. Ambient 122° F (50° C) Temp. Max Load Wind: 62 psf, 3000 Pa, 305 kg/m2 front & back Snow: 125 psf, 6000 Pa, 611 kg/m2 front Impact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 m/s) Warranties 25 -year limited power warranty 25 ear limited product warrant UL listed to UL 1741, including: IEEE1547/1547a and IEEE1547.1/1547.1a Utility Interactive PV Rapid Shutdown Equipment Equipment Grounding UL 6703, UL 9703 Connectors and cables (load break disconnection) UL 1703 PV Modules (Type 2 fire rating) Certifications Enables installation in accordance with: NEC 690.6 - NEC 690.12 Rapid Shutdown (inside and outside the array) NEC 690.15 AC Connectors, 690.33(A) - (E)(1) FCC and ICES -003 Class B When used with InvisiMount racking (UL 2703) Integrated grounding and bonding Class A fire rated PID Test Potential -induced degradation free 1046 mm (41.2 in) I 155R mm iw— (61.3 in] _.___.___.______..►i I Please read the safety and installation instructions for details. Document 4 515215 Rev D /LTR US SPR -X21 -345 -C -AC SPR -X21 -335 -C -AC Nominal Power3(Pnom) 345 W 335 W Power Tolerance +5/-0% +5/-0% Avg. Panel Efficiency` 21.5% 21.0% Temp. Coef. (Power) -0,29%/OC Shade Tolerance Three bypass diodes Integrated module -level maximum power point tracking 'Highest of over 3,200 silicon solar panels, Photon Module Survey, Feb. 2014 1 rank in "PV Module Durability Initiative Public Report,' Fraunhofer CSE, Feb 2013. Five out of th=_ top eight largest manufacturers were tested. Campeau, Z. et al. "Sunpower Module Degradation Rate," Sun?ower white paper, Feb 2013. See www.sunpower.com/facts for details. 'Standard Test Conditions (1000 w/ml irradiance. AM 1.5.25° Q. NREL calibration standard: SOMS current, !ACCS FF and voltage. All DC voltage is fully contained within the module. 'Eased on average of measured pourer values during production. See vrvwa.sunpower.com/facts for more reference information. For more details, see extended datasheet: www.sunpower.com/datasheets. Operating Temp. -40° F to +185° F (-40° C to -85' C) Max. Ambient 122° F (50° C) Temp. Max Load Wind: 62 psf, 3000 Pa, 305 kg/m2 front & back Snow: 125 psf, 6000 Pa, 611 kg/m2 front Impact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 m/s) Warranties 25 -year limited power warranty 25 ear limited product warrant UL listed to UL 1741, including: IEEE1547/1547a and IEEE1547.1/1547.1a Utility Interactive PV Rapid Shutdown Equipment Equipment Grounding UL 6703, UL 9703 Connectors and cables (load break disconnection) UL 1703 PV Modules (Type 2 fire rating) Certifications Enables installation in accordance with: NEC 690.6 - NEC 690.12 Rapid Shutdown (inside and outside the array) NEC 690.15 AC Connectors, 690.33(A) - (E)(1) FCC and ICES -003 Class B When used with InvisiMount racking (UL 2703) Integrated grounding and bonding Class A fire rated PID Test Potential -induced degradation free 1046 mm (41.2 in) I 155R mm iw— (61.3 in] _.___.___.______..►i I Please read the safety and installation instructions for details. Document 4 515215 Rev D /LTR US Output @ 240 V (min./nom./max.) 211/240/264 V Output @ 208 V (min./nom./max.) 183/208/229 V Operating Frequency (min./nom./max.) 59.3/60.0/60.5 Hz Output Power Factor (min.) 0.99 AC Max. Continuous Output Current @ 240 V 1.33 A AC Max. Continuous Output Current @ 208 V 1.54 A AC Max. Cont. Output Power 320 W DC/AC CEC Conversion Efficiency 96.0% Max. Units Per 20 A Branch Circuit @ 240 V 12 (single phase) Max. Units Per 20 A Branch Circuit @ 208 V 10 (two pole) No active phase balancing for 3 phase installations 'Highest of over 3,200 silicon solar panels, Photon Module Survey, Feb. 2014 1 rank in "PV Module Durability Initiative Public Report,' Fraunhofer CSE, Feb 2013. Five out of th=_ top eight largest manufacturers were tested. Campeau, Z. et al. "Sunpower Module Degradation Rate," Sun?ower white paper, Feb 2013. See www.sunpower.com/facts for details. 'Standard Test Conditions (1000 w/ml irradiance. AM 1.5.25° Q. NREL calibration standard: SOMS current, !ACCS FF and voltage. All DC voltage is fully contained within the module. 'Eased on average of measured pourer values during production. See vrvwa.sunpower.com/facts for more reference information. For more details, see extended datasheet: www.sunpower.com/datasheets. Operating Temp. -40° F to +185° F (-40° C to -85' C) Max. Ambient 122° F (50° C) Temp. Max Load Wind: 62 psf, 3000 Pa, 305 kg/m2 front & back Snow: 125 psf, 6000 Pa, 611 kg/m2 front Impact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 m/s) Warranties 25 -year limited power warranty 25 ear limited product warrant UL listed to UL 1741, including: IEEE1547/1547a and IEEE1547.1/1547.1a Utility Interactive PV Rapid Shutdown Equipment Equipment Grounding UL 6703, UL 9703 Connectors and cables (load break disconnection) UL 1703 PV Modules (Type 2 fire rating) Certifications Enables installation in accordance with: NEC 690.6 - NEC 690.12 Rapid Shutdown (inside and outside the array) NEC 690.15 AC Connectors, 690.33(A) - (E)(1) FCC and ICES -003 Class B When used with InvisiMount racking (UL 2703) Integrated grounding and bonding Class A fire rated PID Test Potential -induced degradation free 1046 mm (41.2 in) I 155R mm iw— (61.3 in] _.___.___.______..►i I Please read the safety and installation instructions for details. Document 4 515215 Rev D /LTR US Solar Cells 96 Monocrystalline Maxeon Gen III Front Glass High -transmission tempered glass with anti -reflective coating Environmental Rating Outdoor rated Frame Class 1 black anodized (highest HAMA rating) Weight 45.5 lbs (20.6 kg) iviax. Recommended I 1.3 in. (33 mm) Module Spacing 'Highest of over 3,200 silicon solar panels, Photon Module Survey, Feb. 2014 1 rank in "PV Module Durability Initiative Public Report,' Fraunhofer CSE, Feb 2013. Five out of th=_ top eight largest manufacturers were tested. Campeau, Z. et al. "Sunpower Module Degradation Rate," Sun?ower white paper, Feb 2013. See www.sunpower.com/facts for details. 'Standard Test Conditions (1000 w/ml irradiance. AM 1.5.25° Q. NREL calibration standard: SOMS current, !ACCS FF and voltage. All DC voltage is fully contained within the module. 'Eased on average of measured pourer values during production. See vrvwa.sunpower.com/facts for more reference information. For more details, see extended datasheet: www.sunpower.com/datasheets. Operating Temp. -40° F to +185° F (-40° C to -85' C) Max. Ambient 122° F (50° C) Temp. Max Load Wind: 62 psf, 3000 Pa, 305 kg/m2 front & back Snow: 125 psf, 6000 Pa, 611 kg/m2 front Impact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 m/s) Warranties 25 -year limited power warranty 25 ear limited product warrant UL listed to UL 1741, including: IEEE1547/1547a and IEEE1547.1/1547.1a Utility Interactive PV Rapid Shutdown Equipment Equipment Grounding UL 6703, UL 9703 Connectors and cables (load break disconnection) UL 1703 PV Modules (Type 2 fire rating) Certifications Enables installation in accordance with: NEC 690.6 - NEC 690.12 Rapid Shutdown (inside and outside the array) NEC 690.15 AC Connectors, 690.33(A) - (E)(1) FCC and ICES -003 Class B When used with InvisiMount racking (UL 2703) Integrated grounding and bonding Class A fire rated PID Test Potential -induced degradation free 1046 mm (41.2 in) I 155R mm iw— (61.3 in] _.___.___.______..►i I Please read the safety and installation instructions for details. Document 4 515215 Rev D /LTR US Design -Driven Advantages #1 module aesthetics and efficiency' Unmatched module reliabilityz No electrolytic capacitors 25 -year Combined:Power and Product Warranty Maximize Value for Roof Size system for roof, not string inverter Optimize performance of each module Expand Deployment Options Complex roofs and partial shading Small systems System expandability Simplify & Speed Installation. Factory -integrated microinverter Robust, double -locking AC connectors Design flexibility offsite and onsite No DC string sizing process Fewer installation steps than competing systems Intuitive commissioning Component of Complete System Built for use with SunPower° InvisiMount"I and the SunPower Monitoring System Superior system reliability and aesthetics SERIES Optimize System and Installation Efficiency SunPower° AC Modules, which include a factory -integrated SunPower micrDinverter, provide a revolutionary combination of high efficiency, high reliability, and module -level DC -to -AC power conversion. Designed specifcally for use with SunPower InvisiMouncl and the SunPower Monitoring System, SunPower AC Modules enable rapid installation, best -;n -class system aesthetics, and intuitive visibility into system performance. All this comes with the best Combined Power and Product Warranty in the industry. sunpower.com AT NISP, SUB PANEI'BOARD (NEC 705.12(D)4) DUAL POWER SOURCE PHOTOVOLTAIC & UTILITY OPERATING VOLTAGE 240 RATED OPERATING CURRENT 24 AT MSP OR SUB PANEILBOARD (NEC 705.12(D)7) WARNING! INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS . OVER -CURRENT DEVICE PHOTOVOLTAIC SYSTEM AT MSP (NEC 690.56(C)) EQUIPPED WITH RAPID SHUTDOWN POOL SUB MSP 0 0 PV ARRAY ❑ CD p O p PV ARRAY n 0 0 0 3 01. THE SOIAH OUOTE 145 IOTH ST. TRACY. CA 95316 (2W) 27}9400 BODETTIcONSTRUCTION INC. 920 TOPAZ CT. RIPON, CA 95]66 CSL: 1019941 cuss: e --------------------------------- CLIENT: WILLIAM MCKELLAR 784 WOODBRISGE DR. CHICO, CA 95926 043-430-002-000 SITE ADDRESS: 784 WOODBRISGE DR. CHICO, CA 95926 REVISION: RM DESCRIPTION: DATE: Y LABELS E2 • SCALE: DATE: n/a 25 -Oct -17 Label Notes: _ • Wenlher Resistant & Suitable for the EnvironmW enl DRAN BY: • All Capital Letters • While in Color Letters Lo•rxcn alarerri • Minimum 3/8" Leiter Height • Red Background L C AT BOAOR SUIT PANELBOARD SOLAR PV RD CIRCUIT 1 SOLAR PV CIRCUIT 2 SOLAR P I SYSTEM SOLAR PV MONITOR AT MSP OR SUB PANEILBOARD (NEC 705.12(D)7) WARNING! INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS . OVER -CURRENT DEVICE PHOTOVOLTAIC SYSTEM AT MSP (NEC 690.56(C)) EQUIPPED WITH RAPID SHUTDOWN POOL SUB MSP 0 0 PV ARRAY ❑ CD p O p PV ARRAY n 0 0 0 3 01. THE SOIAH OUOTE 145 IOTH ST. TRACY. CA 95316 (2W) 27}9400 BODETTIcONSTRUCTION INC. 920 TOPAZ CT. RIPON, CA 95]66 CSL: 1019941 cuss: e --------------------------------- CLIENT: WILLIAM MCKELLAR 784 WOODBRISGE DR. CHICO, CA 95926 043-430-002-000 SITE ADDRESS: 784 WOODBRISGE DR. CHICO, CA 95926 REVISION: RM DESCRIPTION: DATE: Y LABELS E2 • SCALE: DATE: n/a 25 -Oct -17 Label Notes: _ • Wenlher Resistant & Suitable for the EnvironmW enl DRAN BY: • All Capital Letters • While in Color Letters Lo•rxcn alarerri • Minimum 3/8" Leiter Height • Red Background L C GONDUC TO115 PEC IFICATIONS CONDUCTOR TEMPURATURE ADJUSTMENT CONDUIT FILL ADJUSTMENT ADJUSTED CONDUCTOR AM PACITY CIRCUIT 1 Operating Voltage 240 Max System Vollage 264 j Operating Current 16 a Snort Circuit Current 20 Modules in CirCuill 12 CIRCUIT 2 Operating Voltage 240 Max System Voltage 264 j Operaling Current 8 O Short Circuit Current 10 < Modules in Circuill 6 PV SYSTEM TOTALS Operating Voltage 240 Max System Voltage 264 > Operating Current 24 Shon Circuit Current30 MAXIMUM PV FEED MSP zoo 1.2x 200 ud0u 121 AL MOW LE ExTE—ON CABLE 6 MODULES CIRCUIT_2g 121 110 THhN-2 -Rs I11 /l2 ANG GRWND JUNCr ION BO)t 111 7 EM 12 MODULES CIRCUIT 1 121 110 —2CWNClORG I 111 112 AN, r„RWND Ill rlIT I I I i I L ELECTRICAL NOTES 1. ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL 2. ALL CONDUCTORS SHALL BE COPPER. RATED FOR 600V 8 90'C WET ENVIRONMENT 3. SUNPOWER AC MODULES SHALL BE INSTALLED TO MANUFACTURERS INSTALLATION INSTRUCTIONS AND COMPLY WITH 690.6 4. AC WIRING IN ATTIC AND WALLS SHALL BE ALLOWED (NMI ROMEX STYLE PER MANUFACTURER RECOMMENDATIONS. 5. SUNPOWER EQUINOX SYSTEM IS GROUNDED THROUGH AC CABLE ASSEMBLY 8 REQUIRES NO ADDITIONAL E.G.C. PER ITS UL 1741 8 2703 LISTING. 6. AC E.G.C. FROM THE JUNCTION BOX TO THE STRUCTURE AC GROUNDING SYSTEM IS ACHIEVED THROUGH (NMI STYLE CONDUCTOR GROUND HARE OR SEPARATE GROUNDING HARE (IF RUN IN METALLIC CONDUIT) AND SIZED TO COMPLY WITH 250.122. 7. SUNPOWER AC MODULES ARE DESIGNED WITHOUT A NEUTRAL CONDUCTOR AS THEY REFERENCE THE GROUND THROUGH THE E.G.C. 8. ALL ROOFTOP CONDUIT TO BE INSTALLED AT A MINIMUM OF 1.5' ABOVE ROOF SURFACE :3 :1144 11414 TMnN-2 ODN OUCrORS 111 1A0.'G GROUND 111 i ENT xa. NEW EQUIPMENT SCHEDULE PV Module SUaPOwer X21.345 -C -AC 18 Junction Box NEMA 3R, 4 4 Monitor SunPower PVSSx 1 Monitor Breaker 15 AMP 2 -POLE 1 Circuit 1 Breaker 20 AMP 2 -POLE 1 Circuit -2 Breaker 20 AMP 2 -POLE 1 EXISTING EQUIPMENT Main Service Panel Rating 200 Main Breaker Rating 200 Sub Panel Rating 100 Sub Breaker Rating 60 Mein Service Panel Cemented YES Grounding Electrode System I UFER NOTE: CENTERFED MSP COMPLIES WITH 2014 NEC 705.12(D)(2)(3)(E) FIB 20OA-2P 121 16 TNNN-2 CCNOUCrORS 111 ;8 AGRWNO Y 111 '” DIT � NAIN SERVICE PANEL I _ I I ]OA -2P I I I IEIGUa PANEL )Q( I THE SOLAR OUOTE 14510TH ST. TRACY.Ca 95376 (269) 27160)0 BCGETTI CONSTRUCTION INC. 620 TOPAZ CT. RIPON, CA 05266 CSL: 1018941 CLASS:8 WILLIAM MCKELLAR 784 WOODBRISGE DR. CHICO, CA 95926 043-430-002-000 SITE ADDRESS: 784 WOODBRISGE DR. CHICO, CA 95926 REVISION: REV. DESCRIPTION: DAT ELECTRICAL EI SCALE: DATE: n/a I 25 -Oct -17 DRAWN 6Y: L. C tlw_ THE SOLAR NOTE 145 IOTN ST. TRACY. CA BS378 (209) x718400 BOOETTI CONSTRUCTION MC, 00 TOPAZ CT. RIPON. CA 05088 CSL: 1018841 CUSS: B WILLIAM MCKELLAR 784 WOODBRISGE DR. CHICO, CA 95926 043-430-002-000 SITE ADDRESS: 784 WOODBRISGE DR. CHICO, CA 95926 REVISION: R EV DESCRIPT- DATE: STRUCTURAL DESIGN ARRAY WEIGHT: 882 LBS. LBS PER SQUARE FOOT: 2.8 Con DETACHED GARAGE LBS PER RACKING FOOT: 27.6 Mar RACK FOOT QUANTITY: 32 RAFTER SIZE: 2 z 4 RAFTER SPACING: 24" O.C. UNSUPPORTED SPAN:6' ROOF PITCH: 30° ROOF TYPE: COMPOSITION SHINGLE PV ARRAY IB E-- ❑ RnP Rnv 12.37' 12.78' NOTE: TYPICAL FRAMING THROUGHOUT RESIDENCE MOUNTING DETAIL 3-5" MOUNTING FEET MAIN RESIDENCE (E) RAFTERS NOTE: MAXIMUM RACKING FOOT SPACING 6' tlw_ THE SOLAR NOTE 145 IOTN ST. TRACY. CA BS378 (209) x718400 BOOETTI CONSTRUCTION MC, 00 TOPAZ CT. RIPON. CA 05088 CSL: 1018841 CUSS: B WILLIAM MCKELLAR 784 WOODBRISGE DR. CHICO, CA 95926 043-430-002-000 SITE ADDRESS: 784 WOODBRISGE DR. CHICO, CA 95926 REVISION: R EV DESCRIPT- DATE: TITLE: MOUNT DETAIL S2 SCALE: OATS: n/a 25 -Oct -17 ORA -BY: gg I. YIixEO CONCEPT-/. y 1. C SYSTEM DESIGN NOTES 18 SnnPower X21 -345 -C -AC 5760 WATTS AC COMPOSITION SHINGLE I -STORY 30° PITCH 180° AZIMUTH -A 20° PITCH 275° AZIMUTH - B RACKING TYPE: SUNPOWER INVISIMO MAIN RESIDENCE LEGEND KEY: I\9SP MAIN SERVICE PANEL ACD AC QISCONNFCT FST -1-31 SU13 PANEL RAP ROOF ACCESS POINT OA7 COM./MONITOR FFR_l JUNCTION BOX FD FRONT DOOR v AC INTERNAL CONDUIT AC EXTERNAL CONDUIT 3' FIRE CODE SETBACK PV MODULE /C\ CH. DAAICI THE SOLRR QUOTE 145 10TH ST. TRACY. CA 85010 (209) 21}0400 ROGETTI CONSTRUCTION INC. 020 TOPAZ CT. RIPON, CA 05]00 CSL: 1019941 CUSS: R WILLIAM MCKELLAR 784 WOODBRISGE DR. CHICO, CA 95926 043-430.002-000 SITE ADDRESS: 784 WOODBRISGE DR. CHICO, CA 95926 REVISION: R V: DESCRIPTION: DATE: TITLE: SITE PLAN SI SCALE: DATE: -I"= 10' 25 -Oct -17 DRAWN BY: IAYIiNF.n DONCF.M7, I, C hWNFR INFl1RMATI nV1 -SHEETTABLE SHEET NUMBER' SHEETTITLE T1 TITLE PAGE Sl; SITE PLAN 'SY MOUNT DETAIL El ELECTRICAL E2 -. LABELS_ CONTACTOR:•A �. THE SOIRR OUOTE 14510TH ST. TRACY, CA 85016 - R091'2119400 y' • ,Sti -- BOGET TRUCTION INC. 920 TO _ .. •' _AZCT. p RIPON,[nN. CA 95166 CSL 1018941,' KW HOTOVOLTA CSYST AC PG&E GRID?IED *•: 7 ;I�' R- f EM, ROOF MOUNTED I' ` ❑ - - _ .CLIENT: SYSTEM SPECS. WILLIAM.IMCKELLAR 00 > 1 .00 784 WOODBRISGE DR. SYSTEM SIZE( WATTS AC)` 5760 , z' . w CHICO, CA 95926 ' PV,NIODULE T.Y•PL': SunPoi4er \2I 345 -C -AC " m 1 043-430-002-000 OF PV MODULES. 18 PV ARRAY AREA (SQFT). .116.± G' I I' APPLICABLE CODES — • � _ SITE ADDRESS: - 2016' -CALIFORNIA ELECTRIC CODE 11993' r 784WQODBRISGEDR, 1_ r 2016` CALIfORNIABUILDINGCODE- +` 4 CHIC0, CA 95926 2016 CALIFORNIA FIRE CODE"' r 2016 "CALIFORNIA RESIDENTIAL CODE+ - - 2014 NATIONAL ELECTRIC CODE - DESIGN CRITERIA • ' - . , , . VICINITY MAP . � ' 1 - .1 REVISION: • ., - . • ... - ,: ,ti ,Ick i �f^+5' - T$+-!^?�; REV: DESCRIPTION: DATE: 0GROUND SNOW LOAD (psQ� c s E n� eft 110 WIND SPEED (mpli) C CATEGORY RATING -3 RECORD LOW TEMPATURE (C°) v ` 36'1 AMBIENT HIGH TEMPATURE (C°) GENERALNOTES I. ,AII equipment shall be installed per,the triarufacturer . instructions.. 2.. Alloutdoorequipment shall be ramtiglit'and hold a minimum NEMA -311 rating... ?. AII >'?lues subject to beroimded to'nest easily available trade size." 4" Data provided by wwwsolarabcs.or ' '. + - . .. • 5. Module -,Mounts and Equipment EriclositrerGi�ounded to Main. O lane Gromid or Ground Rod.. �. � 'S O § TITLE PAGE TI 6. Smoke be and Carbon Monoxide Alarms sfiall;be installed m' 04q r784 WOQdbtidge Drive accordance with. CRC 11314'and'CRC 11313 ' r - 7. This photavoltaic system will be interconnected and operated in t = n. ,r'< i SCALE: parallel with the utility electrical P b 'rid. er the requireinents of the < r 70 ' ane spdrts E'er 618 !1d$@Lt1 ' 25 -Oct -17 'Utility and applicable codes:.,.. - .,. ., , rp q:- p ��. ,.�,.:� ys.. a -v { n/a - - 8. Wiring material outside of structures shall be copper and 90 deg n g `. ', :. g K. { ♦_ + '' t `A DRAWN BY' a•ated,sunable for sun exposure and wet locations. •--� •�- 9. All electrical equipment shall be listed by a i`ecognized electrical k �G{(tg`'FrOtt1 i e BfUSR «F�A - 'testing lalioratoryocapproved bythe dePartmehL 10, TB -e output of?utility interactive-invertedshall be permitted Lobe ;,r connected to the supply side of the set disconnecting iileairs _as per 2'30.82(6) `�, '`•€ .:' _ ''`, ,�- m a - _ � � s SunPower Monitoring Solution, Plug and Play Installation This complete solution for residential monitoring includes the SunPower® PV Supervisor 5X (PVS5x) which improves the installation process, overall system reliability, and customer experience. Compact footprint for improved aesthetics Robust cloud connectivity and comprehensive local connectivity Flexible configuration of devices during installation Consumption monitoring Revenue -grade production monitoring Web -based commissioning app Remote diagnostics of PVS5x and inverters Durable NEMA 3R enclosure reduces maintenance costs Robust Cloud Connectivity Multiple options to maintain optimal connectivity: Hardwired Ethernet Power Line Communication (PLC) Wi-pi Cellular backup Supports Multiple Inverter Types Supports SunPower 96 -cell AC module systems, DC string inverter systems, and hybrid (DC and AC) systems. Weight,, 2.5 kg(5.5lbs) - Dimensions 34.5 cm x 20.6 cm.x 9.3 cm (13.6 in x 81 in x3.6 in) Enclosure Rating Type 3R Homeowner website ' [nonitor.us sunoower:com I - ----- - _. Partner sunpowermonrtorcom/partner, Browsers Firefox, Safari Chrome, Internet Explorer.' ` Mobile Devices. ftoneg: iPad , and Android ", Homeowner A Pp . ; 1. Creaie account online at monitor.us.sun"wer cgs. ® ® o Temperature -30°C to+60°C(-22°F.to+140°F) Humidity (maximum) 9'%, non condensing o RS485 `Inverters and meters ........_....._. 2LC for 96 -cell AC modules _!?. 96 --.._ - ----- -----.. Integrated. Metering One channel ofrevenue-grade production metering (ANSI C12'.20 Class 0.5) and two, channels of net metering Ethernet. ...... WAN and LAN ports --I --- --- --'— I.. i "integrated HomePlu AV standard'commuhication to PLC g PLC devices over AC wiring. wi-Fi Cellular' ]• 3GUMTS ZigBee Home automation= inverter communications; meter readings. USB Type A. 'Supports additional communications up to 0:5 Amps " , :,(for example; Wi-Fi, BluetoothO) I Nemo �_ GB flash Data Storage" , 60 days:.,, , Upgrades, --,omaac"firmV ar_ upgrades fSWr � ir��le Roofs: ka �E a ' � ®° CS 'W o �� • ��" �1v' :®• i5 _ �. to ° � � . �: � v � a a �� �ooo = .� rr : o ©. �$ •a�t3�c� ®� � v o � � ©dei. o. 1905 E 5th Vancouver,WA 98661 Phone -13-6-018 440048 www.sunmodo.com This product must only be connected to a single-phase system (L -L) of a premises with the neutral (N) bonded to ground at the service entrance per code. (The MI does not reference the N to ground internally, therefore this reference must be accomplished only at the service entrance.) Ensure that the installation site has a high-quality N -to -ground reference at the service. The MI determines L -N voltages based on measuring internally from L to the MI chassis, which is connected to the EGC. �...i-✓ A-: i'#%r ck ;-�"m=4'I.�.: *?,,. ...r_< k�la.;'�ai: 3'ri„rt#'#�+ d.ii3.e _,.,.�. a...,zf ..�:.^_-. t. �5�:. ffi. .. ',+:�.'„..... ,6.. ':.'f, -'+: �.,y hq: 4.1 NEC Compliance and the Ground Path The following are the grounding -related NEC Articles and applicability for SunPower AC Modules on rooftops, and are relevant when SunPower AC Modules are mounted on the InvisiMount system: • 690.41 does not apply to AC modules. • 690.42 does not apply to AC modules. • 690.43 covers equipment grounding, which is the only required type of grounding for an AC module. • 690.45 specifies that the EGC for PV Source and PV Output circuits be sized based on 250.122. Per 690.6, requirements in 690 pertaining to PV Source circuits shall not apply to AC modules because the circuits are internal to the Listed AC module. The AC module output is considered an inverter output. Requirements from 250 for equipment grounding are applied from the service to the junction box. The Listed AC Module interconnecting cable system uses the product safety listing standard which is based on section 250.122 and other sections in 250. • 690.46 modifies 690.45 when the EGC is not protected within a raceway. This is not relevant to the AC Module system because the EGC is within the listed AC Module interconnecting cable system. • 690.47 does not apply to AC modules: ■ 690.47(A) does not apply when installing an AC system. The AC "system” was already existing on the premises, and hence you are installing AC modules on the AC system. • 690.47(6) applies to DC systems; it does not apply to AC modules. • 690.47(C) does not apply (see 690.47(6)). • 690.47(D) only provides guidance for a "dc grounding electrode conductor." • 690.48 applies, but isn't relevant. • 690.49 does not apply. • 690.50 applies, but isn't relevant. Note as well that Section 4.1 of the SunPower AC Module Safety and Installation Instructions (#51744) explains: As a Listed product, "SunPower AC modules shall be installed and used in accordance with any instructions included in the listing or labeling" (110.3(6)). In addition, SunPower AC Modules "shall be grounded using the integrated equipment grounding conductor ... no additional grounding conductor attachment to the AC module is required." i �'�Itldlrlg . . `c.�rowteQ»g t'14acoodo �GEf:j Document #508988 RevF 17 1 r SunPower Proprietary tonr�lion�p Bonding Compc�riarits NEC UL .Gtound 0 wrloctrodo to 690 470) - nib sema P4ntl 690.47(0).• ServhQ Panel to 690.43 nlO Ro6ftopJuntflon.84x. 3 toofto un,cdon Box to Pd: 00AWA) 1i41 "3 AC Caifle 9783 AC Coble to Wa (part of 1703 hlltroinve-rter. Usti 1741 Microinvortar to 610 (part.of 1903. AC Mc4ule Frame Ustlrti) 1741 1741 6900 AC Cable to AC Cabin 690:A3(0) 6703 9703 AC Modulep rame to 690.43(A) ?Aid (tam to:Rail 690A3(C) 2703. 690,A3(0) AC Module Fraime to 6" A3(A) F»d Ctamp to.Ratl: 690A3(C) 2703 690:43(D) 690.43(A) Rail to Splice 6"A3(C) 7703 690:43(0) Document #508988 RevF 17 1 r SunPower Proprietary OWNER INFORMATION OWNER NAME: WILLIAM MCKELLAR ADDRESS: 784 WOODBRISGE DR. CHICO, CA 95926 PARCEL NUMBER: 043-430-002-000 PHONE NUMBER: (530) 521-3367 EMAIL ADDRESS: bill.mckellar@sbcglobal.net PROJECT DESCRIPTION INSTALL A NEW 5.8KWAC PG&E GRID TIED 0. PHOTOVOLTAIC SYSTEM, ROOF MOUNTED SYSTEM SPECS. SYSTEM SIZE(WATTS AC): 5760 PV MODULE TYPE: SunPower X21 -345 -D -AC # OF PV MODULES: 18 PV ARRAY AREA (SQFT): 316 APPLICABLE CODES 2016 CALIFORNIA ELECTRIC CODE 2016 CALIFORNIA BUILDING CODE 2016 CALIFORNIA FIRE CODE 2016 CALIFORNIA RESIDENTIAL CODE 2014 NATIONAL ELECTRIC CODE DESIGN CRITERIA 0 GROUND SNOW LOAD (psf) 110 WIND SPEED (mph) C CATEGORY RATING -3 RECORD LOW TEMPATURE (CO) 36 AMBIENT HIGH TEMPATURE (CO) GENERAL NOTES 1. All equipment shall be installed per the manufacturer installation instructions. 2. All outdoor equipment shall be raintight and hold a minimum NEMA -3R rating. 3. All values subject to be rounded to next easily available trade size. 4. Data provided by www.solarabes.org. 5. Module Mounts and Equipment Enclosures Grounded to Main Panelboard Ground or Ground Rod. 6. Smoke Detectors and Carbon Monoxide Alarms shall be installed in accordance with CRC R314 and CRC R315 7. This photovoltaic system will be interconnected and operated in parallel with the utility electrical grid per the requirements of the utility and applicable codes. 8. Wiring material outside of structures shall be copper and 90 deg rated, suitable for sun exposure and wet locations. 9. All electrical equipment shall be listed by a recognized electrical testing laboratory or approved by the department. 10. The output of a utility interactive -inverter shall be permitted to be connected to the supply side of the service disconnecting means as \ per 230.82(6) DA D!'CII N DRIVEWAY W A El V 100.00' A a O O I I 119.93' SHEET TABLE SHEET NUMBER SHEET TITLE T1 TITLE PACE S1 SITE PLAN S2 MOUNT DETAIL E1 ELECTRICAL E2 LA_BE:L:S:::7] VICINITY MAP .....+.w.M�.++,i �ia.{rnw+.r� y�� 4 i�. t • � ±�S ., r' 4 n 3,7 � t � ! } . { � y'.."d T '�.� ..- � � ' � ��..�'y+�''r'r'J �.. pz J i 1�j ..e�•T-sy 9 i ! Awli f� 5. ..r � 'i� It i �..*. =,_ �* �-,',ray•.'..'"'- .._,., . �. J lick ia- inkl 41 ps Or VLI , it d5rirlge Rinre,� � , ' v;i' ,t ,'A.•ln` 4 "�aL' Y R ,...o- �s.f ►xr- 6.. .K x�y r� ,may +J, .i"�' f. - . 7 # C `-� F • �4 �'i+t�t - . - ...i�.�. jONTACTOR: ti, THE SOLRR QUOTE 145 10TH ST. TRACY, CA 95376 (209) 273.8400 BOGETTI CONSTRUCTION INC. 920 TOPAZ CT. RIPON, CA 95366 CSL: 1018941 CLASS: B CLIENT: WILLIAM MCKELLAR 781 WOODBRISGE DR. CHICO, CA 95926 043-430-002-000 SITE ADDRESS: 784 WOODBRISGE DR. CHICO, CA 95926 TITLE PAGE #��V:�.. 'pF,`�j ;-1-@ - , �S r.'e.w-*..q.' .f i y1 t'�""...'.^'s_r^..►a+mo«w,i .wa+ti-..nw_.s ✓LejiFe _L`:f�. ' L*'ti._„wt_,_w, ` Vt rS �` z ) vaald cfl.,,rj y�//jft DRAW N BY'� f LAY ERED CONCEPTZQ. iQ_ j�� y 1flS Fr01L i t i�14yr :. f ,� 3#i F ,r �•� L { !4) '7 , _ �� �' ��ve �' . k �.�q ]a a'1 1• �. l �.r f� f � 1 - t ��.tir..r.r: i r�V I i � � - � -- i F C.`_. _ . _.•ra.'�""�"�..._. -���� f_.�, ..�1.._.,.—. _ ._ _ :Lf _ a J .Sr��._. <<..f.___....... a,.ii' — 4L T1 DATE: 25 -Oct -17 _ SYSTEM DESIGN NOTES • 18 SunPower X21 -345 -D -AC • 5760 WATTS AC • COMPOSITION SHINGLE • 1 - STORY • 300 PITCH 1800 AZIMUTH - A • 200 PITCH 2750 AZIMUTH - B • RACKING TYPE: SUNPOWER INVISIMO r .IF M' MAINRESIDENCE LEGEND KEY: MSP MAIN SERVICE PANEL ACD AC DISCONNECT FS—U B-1 SUB PANEL ® ROOF ACCESS POINT COM COM./MONITOR JB JUNCTION BOX FD FRONT DOOR 'AC INTERNAL CONDUIT e AC EXTERNAL CONDUIT Y FIRE CODE SETBACK PV MODULE /C% 01 io MAPir!l CONTACTOR: N . THE SOLRR NOTE 145 10TH ST. TRACY, CA 95376 (209) 273-8400 BOGETTI CONSTRUCTION INC. 920 TOPAZ CT. RIPON, CA 95366 CSL: 1018941 CLASS: B CLIENT: WILLIAM MCKELLAR -784 WOODBRISGE DR. CHICO, CA 95926 naz-azn-nm-nnn SITE ADDRESS: 784 WOODBRISGE DR. CHICO, CA 95926 REVISION: REV: I DESCRIPTION: I DATE: TITLE: \ SITE PLAN SI SCALE: DATE: 1" = 10' 25 -Oct -17 DRAWN BY: LAYERED CONCEPTZ L C STRUCTURAL DESIGN • ARRAY WEIGHT: 882 LBS. • LBS PER SQUARE FOOT: 2.8 • LBS PER RACKING FOOT: 27.6 • RACK FOOT QUANTITY: 32 • RAFTER SIZE: 2 x 4 • RAFTER SPACING: 24" O.C. • . UNSUPPORTED SPAN:6" • ROOF PITCH: 301 • ROOF TYPE: COMPOSITION SHINGLE NOTE: TYPICAL FRAMING THROUGHOUT RESIDENCE MOUNTING DETAIL 30- RAL ROOF filtIr % ]-1l1' SS LAG BOLT MINIMUM 2. V2' THREAD EMBEDMENT SEALED M7H CHEMLINK M 1 (OR EOUN.) 3-511f _ MOUN'TIN'G FEET • (E) RAFTERS MAIN RESIDENCE NOTE: MAXIMUM RACKING FOOT SPACING 6' CONTACTOR: N 4 TIRE SOLRR QUOTE 145 10TH ST. TRACY, CA 95376 (209) 273.8400 BOGETTI CONSTRUCTION INC. 920 TOPAZ CT. RIPON, CA 95366 CSL: 1018941 CLASS:13 CLIENT: WILLIAM MCKELLAR 794 w6or)RRISG. DR. • . CHICO, CA 95926 043-430-002-000 SITE ADDRESS: 784 WOODBRiSGE DR. CHICO, CA 95926 TITLE: ----MOUNT-DE-T-AIL---S2 -- --- -- DATE: 25 -Oct -17 DRAWN BY: f '4a LAYERED CONCEPTZ LC CONIJUCTOR SPECIFICATIONS CONDUCTOR TEMPURATURE ADJUSTMENT CONDUIT FILL ADJUSTMENT ADJUSTED CONDUCTOR AMPACITY MATERIAL TEMP. RATING TRADE SIZE RATED AMPACITY CONDUCTORAVG. LOCATION HIGHTEMP. HEIGHT ABOVE ROOF010.15(Tx0)(p) TEMP. ADDER(C•I CONDUCTOR ADJUSTED TEMP. (C-) AMPACITY CORRECTION FACTOR #OF CURRENT -CARRYING CONDUCTORS USTMENT AMPAC%' CTOR FA 010.15(BK0)4) CONDUCTOR AMPACRV TEMP. CONDUIT FILLADJUSTED x CORRECTION z ADJUSTMENT = AMPACITY FACTOR FACTOR Copper 90°C #12 30 Rooftop, Conduit 36 1.5 22 58 ':71 +:: 4 30 X x'.:.71I X V- ` = M "17 ;. Copper 90°C #12 30 Attic, Free Air 36 n/a n/a 36 .91 n/a wa _ 30 x t .91 3i x r n/a '� = M.`' 27 Copper 90°C #12 30 UndrGnd, PVC 36 n/a n/a 36 %?.91'• 4 8_ 30 X 11"":91'-4 X 1 .. 8 1= �,'22�-, Copper 90°C #10 40 Wall, Conduit 36 n/a n/a 36 - .91 = II ^ :91,,°@ x J.+'..1 . R = ` 36, CIRCUIT 1 1n Operating Voltage 240 � Max System Voltage 264 > Operating Current 16 L)Short Circuit Current 20 Q Modules in Circuit 12 CIRCUIT 2 1n Operating Voltage 240 Z3 Max System Voltage 264 > Operating Current 8 U Q Short Circuit.Current 10 Q Modules in Circuit 6 6 MODULES CIRCUIT 2 12 MODULES CIRCUIT 1 PV SYSTEM TOTALS m Operating Voltage 1 240 M Max System Voltage 264 > Operating Current 24 U Q Short Circuit Current 30 (2) AC MODULE EXTENSION CABLE MAXIMUM PV FEED MSP Main Service Panel Rating Y MAkPMUM BUSSBAR I 10% gIN, ER - PV Module AMPACRY )05.12(D)(2) AMPACT AMPERES 200 X 1:2 200 = 40 (MONITOR (2) 410 THWN-2 CONDUCTORS (1) #12 AWG GROUND JUNCTION BOX (1) 7" EMT ----V —------ ----� NEW EQUIPMENT SCHEDULE Main Service Panel Rating • EQUIPMENT MODEL Qt applicaMo) OR RATING OTY. PV Module SunPowerX21-345-D-AC 18 Junction Box NEMA 3R, 4 4 Monitor SunPower PVS5x 1 Monitor Breaker 15 AMP 2 -POLE 1 Circuit 1 Breaker 20 AMP 2 -POLE 1 Circuit 2 Breaker 20 AMP 2 -POLE 11 (3) #14 THWN-2 CONDUCTORS (1) 414 AWG GROUND (1) a" EMT EXISTING EQUIPMENT Main Service Panel Rating 200 Main Breaker Rating 200 Sub Panel Rating 100 Sub Breaker Rating 60 Main Service Panel Centerfed YES Grounding Electrode System UFER NOTE: CENTERFED MSP COMPLIES WITH 2014 NEC 705.12(D)(2)(3)(E) MB 1 20DA-2P F-- -- ---------. I (2)- #6 THWN-2 CONDUCTORS (� (1) #,8 AWG GROUND ! I (1) J" EMT MAIN SERVICE PANEL (2j #10 THWN-2 CONDUCTORS ! (1) #12 AWG GROUND 1 f (1) 1" EMT — 2DA-2P I� ELECTRICAL NOTES (ej sus PANEL 1. ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL -- -- -- - -- - --- ---=tl_. 2:-- --ALL-CONDUCTORS-SHALL BE COPPER, -RATED -FOR 600V 8-90°C'WET ENVIRONMENT--------- 3. SUNPOWER AC MODULES SHALL BE INSTALLED TO MANUFACTURERS INSTALLATION INSTRUCTIONS AND COMPLY WITH 690.6 4. AC WIRING IN ATTIC AND WALLS SHALL BE ALLOWED (NM) ROMEX STYLE PER MANUFACTURER RECOMMENDATIONS. 5. SUNPOWER EQUINOX SYSTEM IS GROUNDED THROUGH AC CABLE ASSEMBLY & REQUIRES NO ADDITIONAL E.G.C. PER ITS UL 1741.8 2703 LISTING. 6. AC E.G.C. FROM THE JUNCTION BOX TO THE STRUCTURE AC GROUNDING SYSTEM IS ACHIEVED THROUGH (NM) STYLE CONDUCTOR GROUND WIRE OR SEPARATE GROUNDING WIRE (IF RUN IN METALLIC CONDUIT) AND SIZED TO COMPLY WITH 250.122. 7. SUNPOWER AC MODULES ARE DESIGNED WITHOUT A NEUTRAL CONDUCTOR AS THEY REFERENCE THE GROUND THROUGH THE E.G.C. 8. ALL ROOFTOP CONDUIT TO BE INSTALLED AT A MINIMUM OF 1.5" ABOVE ROOF SURFACE // CONTACTOR: THE SOLAR QUOTE 145 10TH ST. TRACY, CA 95376 (209) 273-8400 BOGETTI CONSTRUCTION INC. 920 TOPAZ CT. RIPON, CA 95366 CSL: 1018941 CLASS: B jLIENT: WILLIAM MCKELLAR 784 WOODBRISGE DR. CHICO, CA 95926 043-430-002-000 SITE ADDRESS: 784 WOODBRISGE DR. • . CHICO, CA 95926 ELECTRICAL El SCALE: 1 tlra t DATE: 25-oct-17 DRAWN BY: LAYEREDCONCEPTZ LC AT MSP, SUB PANELBOARD (NEC 705.12(D)4) DUAL POWER SOURCE PHOTOVOLTAIC & UTILITY OPERATING VOLTAGE 240 -RATED OPERATING CURRENT 24 AT MSP OR SOLAR PV CIRCUIT 1 SUB PANELBOARD SOLARPV CIRCUIT 2 SOLAR PV SYSTEM SOLAR -'PV I MONITOR - AT MSP OR SUB PANELBOARD (NEC 705.12(D)7) WARNING! INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVER -CURRENT DEVICE: AT MSP (NEC 690.56(C)) PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN .AY Label Notes- • Weather Resistant & Suitable for the Environment • All Capital Letters • White in Color Letters • Minimum 3/8" Letter Height • Red Background %ONTACTOR: THE SOIRR QUOTE 145 10TH ST. TRACY. CA 95376 (209) 273.8400 BOGETTI CONSTRUCTION INC. 920 TOPAZ CT. RIPON, CA 95366, CSL: 1018941 CLASS: B t jLIENT: WILLIAM MCKELLAR 784 WOODBRISGE DR. CHICO, CA 95926 043-430-002-000 SITE ADDRESS: 784 WOODBRISGE DR. CHICO, CA 95926 TITLE: LABELS E2 DATE: 25 -Oct -17 DRAWN BY: LAYERED CONCEPTZ LC