Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B17-2440 047-100-107
BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspections is 3pm) Development Services cannot guarantee inspections on the date requested Office: 530.538.7601 Fax: 530.538.7785 www.ButteCountv.net/dds Permit No: B17-2440 Issued: 10/12/2017 APN: 047-100-107 Address: 15085 MERIDIAN RD, CHICO Owner: BOYD BRENT L & L RENEE Permit Type: SOLAR ROOF -RES Description: ROOF MNT SOLAR (8.25 KW) AREA 4 Flood Zone: None SRA Area: Yes Front: Centerline of Road: Rear: SRA: Street: AG: Interior Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING Inspection TVpe IVR INSP DATE Setbacks 131 Foundations / Footings 11 f Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Signed Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 Blockin nde inin 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed Shearwall/B.W.P.-Interior 134 Shearwall/B.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 417 Manometer Test Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Plumbing Final 813 Fire Sprinkler Test or Final 702 Swimming Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barrie rs 503 Pre -Plaster 507 Manufactured Homes Setbacks 131 Blockin nde inin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Skirtin Ste s/Landin s 610 Coach Info Manufactures Name: Date of Manufacture: el Name/Number: Serial Numbers: [Mod Len th x Width: Insignia: ,Finals Permit Final 802 Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test or Final 702 Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final "PROJECT FINAL I I top 11k ( -rrolecr anal is a %-eruncare or uecupancy ror tKesiaennai vmy) PERMITS BECOME NULL AND VOID l YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT 24 HOUR INSPECTION (IVR)#:530.538.4365 ` OFFICE #: 530.538.7601 FAX#:530.538.7785 www.ButteCounty.net/dds N1��i��r.'�t+y'�'�;u �ti, _' �+i` Cs'..`''"'��. 1�'�`"'�'�,PRO;TE'CT{INFORMATION' �,'�� �:;.;�� `�h �,•j,�,, "14 e��:klu.�.. i.�w�.3.� n � �:.,.',s'r Site Address: 15085 MERIDIAN RD 'viwv, Owner: Permit NO: B 17-2440 APN: 047-100-107 the reason(s) indicated below by the checkmark(s) I have placed next to the applicable item(s) (Section BOYD BRENT L & L RENEE 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the Permit file a signed statement that or she licensed pursuant to the provisions of the Contractors' Pennit type: MISCELLANEOUS I (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license i c P O BOX 1843y Issued Date: 10/12/2017 B DAH Subtype: SOLAR ROOF -RES X CHICO, CA 95927 Expiration Date: 10/12/2018 Description: ROOF MNT SOLAR (8.25 KW) Contractor's Signature Date Occupancy: Zoning: Al0 Contractor I HEREBY AFFIRM UNDER PENALTY OF PERJURY one of the following declarations: Applicant: Square Footage: FREEDOM SOLAR SERVICES DBA burden of proving that it was not built or FREEDOM SOLAR Building Garage Remdl/Addn 30605 SORREL LANE 30605 SORREL LANE 0 0 0 CANYON LAKE, CA 92587 CANYON LAKE, CA 92587 Other . Porch/Patio Total 9513210855 9513210855 0 0 0 14*5 LICENSED,;CONTRACTQR'S�DECLFARATION' Al,I,tr sub. t -,)i- ,:OWNER /.BUILDERDECLARATION_ 'viwv, Contractor (Name) State Contractors License No. / Class / Expires I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for FREEDOM SOLAR 982892 / C10 / 4/30/2019 the reason(s) indicated below by the checkmark(s) I have placed next to the applicable item(s) (Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the Permit file a signed statement that or she licensed pursuant to the provisions of the Contractors' I HEREBY AFFIRM UNDER PENALTY OF PERJURY that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license i c cing with Section 7000) of Division 3 0( the Business and ense Law (Chapter 9 (commencing State License in full force and effect. 3 Professions Code) or that he or she is exempt from licensure and the basis for the alleged exemption. X Any violation of Section 7031.5 by any applicant for a permit_ subjects the applicant to a civil penalty of o. not more than five hundred dollars ($500).): ❑ ~ I, as owner of the property, or my employees with wages as their sole compensation, will Contractor's Signature Date do U all of or U portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who. through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the M FS ,WORKERS ' COMPENSATION: DECLARATIOWR.W I HEREBY AFFIRM UNDER PENALTY OF PERJURY one of the following declarations: building or improvement is sold within one year of completion, the Owner -Builder will have the have and will maintain a certificate of consent to self -insure for workers' burden of proving that it was not built or ❑I compensation issued by the Director of Industrial Relations as provided for by Section improved for the purpose of sale.). 3700 of the Labor Code, for the performance of the work for which this permit is issued. Policy No. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: STATE Policy Numb%5224j Exp. QMQMI2018 E] I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those • provisions. X Signature Date WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. i C;QNSTRUCTI,ON;LENDINGAGEN;CY4DECLARATIONs'W- I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Section 3097, Civil Code). Lender's Name and Address Lender's Name & Address City' State Zip I, as owner of the property, am exclusively contracting with licensed Contractors to construct the project (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a licensed Contractor pursuant to the Contractors' State License Law.). I am exempt from licensure under the Contractors' State License Law for the following reason: Owner's Signature Date By my signature below, I certify to each of the following: I am U a California licensed contractor or U the property owner' or L) authorized to act on the property owner's behalf**. I have read this construction permit application and the information I have provided is correct. I agree to comply with all applicable city and county ordinances and state laws relating to building construction. I authorize representatives of this city or county to enter the above -identified property for inspection purposes. California Licensed Contractor, Property Owner' or Authorized Agent": 'requires separate verification form 'requires separate authorization form X• .Name of Permittee [SIGN] Print Date U '11 "'5 e.,wN, A j -ft, ..rr., ;•` vRxt n}: : i ¢� �t14 t4_� °b i's� Total Fees: $512.00 Fees Paid: $512.00 Balance Due: (None) 'Job Value: $31,000.00 TABLE OF CONTENTS PV -1 SITE LOCATION AND HOUSE AERIAL VIEW PV -2 F SYSTEM SUMMARY: 8:250 KVV r r ROOF MOUNT RESIDENTIAL PHOTOVOLTAIC SYSTEM ' SYSTEM SIZE (DC) STC: 30 X 275= 8250W DC. f , PV -4 PTC: 30 X 249.20 = 7476.00W DC SYSTEM SIZE (CEC-AC) : 30 X 249.20 X 98% = 7326.48W At MODULES 30 X CANADIAN SOLAR ALL BLACK CS6K-275M,•275W INVERTER :- SOLAR EDGE SE760OH-US , ROOF ,. COMPOSITION SHINGLE TILT - 19° PITCH AZIMUTH 135°& 315'- - RAFTER/TRUSS SIZE : 2" X 2" RAFTERS @ 24" O.0 EC065 WITH IRONRIDGE XR100 RAIL ATTACHMENT -TYPE EXISTING 200 AMPS MSP WITH 200 AMPS MAIN „ 'MAIN SERVICE PANEL : BREAKER ON TOP FEED INTERCONNECTION TIED TO PV BREAKER IN SUBPANEL 40 AMPS OCPD RATING 2 STRING WITH 15 MODULES IN SERIES IN EACH STRINGING : STRING _ UTILITY PACIFIC GAS AND ELECTRIC COMPANY (PGE) TABLE OF CONTENTS PV -1 SITE LOCATION AND HOUSE AERIAL VIEW PV -2 SITE•PLAN - PV -2A ROOF.PLAN WITH MODULES LAYOUT PV -3 ELECTRICAL LINE DIAGRAM PV -4 ROOF MOUNTING DETAILS, ELEC. CALCULATION & MATERIAL LIST PV -5 LABELS t RH0T0V0LTA1C-'SYSTEM'_'..- ,CITY NOTES: THIS PROJECT COMPLIES WITH THE FOLLOWING:' . 2016 CALIFORNIA BUILDING CODE (CBC) 2016 CALIFORNIA ELECTRICAL CODE (CEC) 2016 CALIFORNIA FIRE CODE (CFC) 2016 CALIFORNIA PLUMBING CODE ` 2016 CALIFORNIA MECHANICAL CODE 2016 CALIFORNIA ENERGY CODE 2016 CALIFORNIA RESIDENTIAL CODE' 2016 CALIFORNIA ADM INISTRATIVE'oCODE AS ADOPTED BY COUNTY OF BU.}y}Ty,,�; ALL SOLAR ENERGY SYSTEM.l ,,)- UIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR . ` - TO THE SURFACE UPON WHICH THEY ARE MOUNTED ` VISIBLE PORTIONS OF THE SOLAR PANEL SUPPORT STRUCTURE AND ANY EXPOSED_ ELECTRICAL CONDUITS, BOXES AND PANELS WILL NOT BE EXPOSED, AND WILL BE _ COLORED MATCHED TO EXISTING ROOF OR SURROUNDING HOME. MODULES SHALL BE TESTED ,-LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN ACCORDANCE WITH UL 1703 sT`iE,FIRE CLASSIFICATION SHALL COMPLY WITH TABLE 1505.10F THE CALIFORNIA BUILDING CODE BASED ON THE TYPE OF CONSTRUCTION OF THE BUILDING. CRC SECTION R902.4 SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER CRC SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. RESIDENTIAL BUILDING UNDERGROUND ADDITION OR IMPROVEMENTS SHALL REPLACE NON-COMPLIANT PLUMBING FIXTURES WITH WATER CONSERVING PLUMBING FIXTURES IN ACCORDANCE WITH CGBSC SECTIO4301.1:1 AND CIVIL CODE 1101.1 AS FOLLOWS: , '—WATER CLOSETS: 1.6 GPF (GPF= GALLONS PER FLUSH) —FAUCETS (ALL INTERIOR) 2.2 ( GPM = GALLIONS PER MINUTE) —URINALS 1.0 GPF . —SHOWER HEADS 2.5 GPM ' INSTALLATION NOTES: r - THE PV BREAKER SHALL NOT EXCEED 120% OF THE ALLOWABLE BACK FEED OF THE MAIN ' SERVICE BUSS RATING. • S^Y PV WIRE SHALL BE USED ON DC RUNS FOR UNGROUNDED/TRANSFORMERLESS INVERTERS.* INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUITS ARE ATTACHED TO THE ROOF USING PRESSURE TREATED WOOD IN CASE OF COMPOSITE ROOF OR COUNDUIT HANGERS IN CASE OF CONCRETE ROOF njJ :CA�2562 actorN« CLIENT: r`111 2892 • e� Freedom SolaBOYD, BRENT & LEANN - BJ151201 15085 MERIDIAN RD, - Freedom Solar. CCHICO, CA 95973 25819 Jefferson Ave, Suite 110, Murrie(530) 392-6270 R r Tel: (800) 385-1075 - .: S SITE LOCATION: _ .Munjar Rd' • L .... Jato Rd .:�.;..,' :�' :.r,.:.Jbkt Rd: m-. ... rT.. �. 44 wt �Y 15085MenfiianRoad'w ; y F ti ridian 1C9 Recon O i SITE LOCATION t HOUSE AERIAL VIEW: REVISIONS: DATE: 10/04/2017 DESCRIPTION DATE REVISION DESIGN GREG - BY: JOB NO.: FS -10-015 MODULE LOCATION TITLE: SHEET: SITE LOCATION AND PV_� ` HOUSE AERIAL VIEW 666'-7" •'r SITE PLAN SCALE: 1/128" = V-0" 1 EladrimlContactor Na C-10 982892 Freedom Solo = Freedom Solar Co 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 Tel: (800) 385-1075 CLIENT: BOYD, BRENT & LEANN - BJ 151201 15085 MERIDIAN RD, CHICO, CA 95973 (530) 392-6270 REVISIONS: DATE: 10/04/2017 TITLE: SITE PLAN SHEET: PV -2 DESCRIPTION DATE REVISION DESIGN By. GREG JOB No.: FS -10-015 r (E) SUB PANEL '(N) AC DISCONNECT (N) SOLAREDGE 760OH-US INVERTER. 'a Q(N) JUNCTION BOX a Q(N) 3/4" EMT CONDUIT \\\ \ \ y (N) 30 CANADIANSOLAR ALL BLACK CS6K-275M, 275W 2 N) ATTACHMENT POINTS @ 48" O.C. MAX. \ \� \ h\ \\\ (E) MAIN SERVICE PANEL —y. . . ROOF AREA STATEMENT MODULES ROOF PITCH AZIMTUH ROOF AREA ARRAY AREA 1 26 19° 315° " 940.66 SQ FT 468.81 SQ'FT 2 4 19° 135° 887.16 SQ FT 71.95 SQ FT t _ NOTE: 7 EMT CONDUIT SUPPORTED BY PIPE Al HANGERS 12" TO 18" AWAY FROM ROOF EDGE ATTACH CLAMP AT 25% FROM EDGE AND 2" X 2" RAFTERS @ 24" O.0 (TYP.) © 50% FROM CENTER OF MODULES Q JUNCTION BOX MOUNTED TO THE RAIL LEGEND: x CHIMNFY FIRE SETBACKS 3' TYP FIRE ACCESS POINTS ROOF PLAN WITH MODULES LAYOUT 1 SCALE: 1/16" = V-0" EieCMMI Cwtmdw No: CLIENT: REVISIONS: DATE: 10/04/2017 TITLE: SHEET: C-10 982892 DESCRIPTION DATE REVISION Freedom Solar BOYD, BRENT & LEANN - BJ 151201 15085 MERIDIAN RD, DESIGN ROOF PLAN WITH Freedom Solar Co CHICO, CA 95973 BY: GREG PV -2A 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 (530) 392-6270 MODULES LAYOUT Tel: (800) 385-1075 JOB NO.: FS -10-015 9 Max.,OCPD: (125A Bus) " (1.2) = 150A Max Rating (120% of Bus) PV Backfeed (40A) + Main Breaker (100A) _ (140A:5 150A) See 705.12 (D)(2)(3)(b) of 2016 CEC STRING -1 15 CANADIAN SOLAR ALL BLACK CS6K-275M, 275W 4 - #10 AWG, THWN-2 1 - #8 EGC, THWN-2 IN 3/4" EMT CONDUIT SOLAREDGE P320 • � POWER OPTIMIZE (E) 200A MAIN SERVICE PANEL (E) 100A / 2P SUB FEEDER BREAKER (E) 125A SUBPANEL BREAKER r--�--� RS INVERTER /._ SOLAREDGE TO OTHER gg 7600H -US LOADS IRAPID SHUTDOWN I STRING -2 AC SWITCH 15 CANADIAN SOLAR ALL BLACK I 60A, AC I CS6K-275M, 275W DC I DISCONNECT 40A / 2P PV BREAKER I JUNCTION o BOX-------------- --- ��------- --- ��-------- ------ --; --ti -----� j SOLAREDGE P320 3 -#8 AWG, THWN-2 I— POWER OPTIMIZERS . j 1 - #8 EGC, THWN-2 IN 3/4" EMT CONDUIT ----------------- – ----J { y UTILITY , METER —o 0 0- ' O \ o� \O - ` 7(E) 200A / 2P MAIN BREAKER �0 1• IS 2 - #10 AWG, PV WIRE 1 - #6 EGC, BARE COPPER (TYP.2) - CONNECT TO EXISTING UFER General Notes 1. (30) CANADIAN SOLAR ALL BLACK CS6K-275M, 275W wired and listed to UL1703 standards 8. System Grounding Electrode conductor for PV system to be sized to meet the requirements of CEC 2016 table 250.66, not smaller than #8 CU AWG." 2. SOLAREDGE 760OH-US Inverter with integrated DC Disconnect and Arc Fault Protection. Attached with system electrical specifications and ground fault protected & listed to UL1741 standards. 9. If the existing main service panel does not have a ground rod or ufer, it is the pv contractors responsibility install one. 3. Photovoltaic system ground will be tied into existing ground at main service from DC Disconnect/Inverter as per CEC 10. Smoke alarms and carbon monoxide detectors will meet the necessary requirements per CRC R314, R315 Sec. 250.166(A). "The Grounding Electrode Conductor shall not be smaller than the neutral conductor and not smaller than 8AWG copper." 11. UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM. 4. Equipment operating 150 volts or greater shall only be serviced or replaced by qualified personnel. Field protection may 12.Terminals of the disconnecting means may be energized in the open position. be in the form of conduit, closed cabinet or an enclosure which requires _use of tools to open. 13. A signage labeled "SOLAR LOADS ONLY" is to be installed on dedicated solar sub panel to be used for PV only. •5. Solar Photovoltaic System equipment will be installed in accordance with requirements of Art. 690 of the 2016 CEC. 14. Solaredge inverters are listed to UL1741 and UL1699B standards. - 6.Minimum height of conduit above roof to match temperature derating factor. 1 15. Solaredge Optimizers are listed to IEC62109-1 (class II safety) and UL1741 standards. 7.Photovoltaic DC conductors entering the building shall be installed in metallic raceway and shall be identified every 10 feet -- and within 1 foot above and below penetrations of roof/ceiling assemblies, walls, or barriers -- with minimum 16. PV system is using continuous grounding method with #6 bare copper wire. 3/8 -inch -high white lettering on red background reading:"WARNING: PHOTOVOLTAIC POWER SOURCE" CLIENT: REVISIONS: TITLE: SHEET: C-10 982892 DATE: 10/04/2017 Freedom So tar BOYD, BRENT & LEANN - BJ 151201 DESCRIPTION DATE REVISION 15085 MERIDIAN RD, DESIGNELECTRICAL CHICO, CA 95973 BY: Freedom Solar Co GREG LINE DIAGRAM V-3 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 (530) 392-6270 Tel: (800) 385-1075 JOB NO.: FS -10-015 Solar Modules ELECTRICAL CALCULATIONS EcosS (Bracket option BACKFEED BREAKER SIZING Z-202) Flashed Roof Bracket MAX. CONTINUOS OUTPUT 32A @ 240V 32 X 1.25 = 40.00AMPS 40A BREAKER - OK Ironridge Racing CEC 705.12 (D) (2) (3) (b) Comp. shingle 125 X 1.20 = 150 2' x 2" Rafter @ 16" O.C. 150 - 100 = 50A ALLOWABLE BACKFEED DE -RATED AMPACITY OF 8 AWG CONDUCTOR @ 0.87 (e)t14 x 1.5" extra duty rooting fasteners TEMPERATURE CORRECTION - into 1/2" plywood shealing with 1.5' min. 55 X 0.87 = 47.85 AMPS - OK embedment, staggered every 48" o.c. ATTACHMENT DETAIL 1 SCALE: NTS Existing composition shingle roof End Clamp Photovoltaic Module 5/16" diameter 3.5" length lag screw i— Mid Clamp MATERIAL LIST QTY EQUIPMENT DESCRIPTION CANADIAN OPEN CIRCUIT VOLTAGE (Voc) : 38.3V SOLAR ALL MAX. POWER VOLTAGE (Vmp) : 31.3V • 30 BLACK SHORT CIRCUIT CURRENT (Isc) : 9.31A CS6K-275M, MAX. POWER CURRENT (Imp)•: 8.80A 275W PTC RATING: 249.2W SOLAR EDGE MAX. DC INPUT VOLTAGE: 350V SE760OH-US MAX. AC OUTPUT VOLTAGE RANGE: 211-240V 1 WITH POWER MAX. AC OUTPUT CURRENT: 32A MAX. AC POWER OUPUT : 760OW OPTIMIZER . CEC EFFICIENCY: 98% 1 JUNCTION BOX 60OVDC, NEMA 4X, UL LISTED 1 AC DISCONNECT 600VAC, 60A, NEMA 3R, UL LISTED 1 PV BREAKER 2 POLE, 240V, 40A 62 ATTACHMENTS EC065 ATTACHMENTS 167' RAIL IRONRIDGE XR100 IRONRIDGE XR100 GROUNDING 50 MID CLAMPS MID CLAMPS 20 END CLAMPS IRONRIDGE XR100 END CLAMPS 40' CONDUIT 3/4" EMT CONDUIT Existing 2" X 2" --J \� 6"max RAFTERS @ 24" O.0 IronRidge per PV Support "Mininum 2.5" Lag Screw Embedment Photovoltaic Panel Mounting Detail Scale: NTS Elg n.1C.,&=arNa CLIENT: REVISIONS: TITLE: SHEET: � DATE: :RE 017 •, ez ,' Freedom Solar C-10 982892 BOYD, BRENT & LEANN BJ 151201 DESCRIPTION DATE REVISION ROOF MOUNTING 15085 MERIDIAN RD, DESIGN DETAILS, ELEC. PV -4 Freedom Solar Co CHICO, CA 95973 BY:CALCULATION & 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 (530) 392-6270 Tel: (800) 385-1075 JOB No.:15 MATERIAL LIST LABELS: LABELS SPECIFICATION: 1. ALL CAPITAL LETTERS 2. MINIMUM 3/8" LETTER HEIGHT 3. ARIAL OR SIMILAR, NON -BOLD 4. WHITE LETTERING IN RED BACKGROUND 5. WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (DURABLE ADHESIVE MATERIALS MUST MEET THIS REQUIREMENT 6., ALL SIGNS SHOULD BE REFLECTIVE DISCONNECTION MEANS ALL AC AND DC DISCONNECTS TO BE • MARKED AS DISCONNECTING MEANS PER CEC 2016 690.13(B) AC DISCONNECT PHOTOVOLTAIC DISCONNECT FOR UTILITY OPERATION AC DISCONNECT INVERTER EQUIPPED WITH RAPID SHUTDOWN JUNCTION BOX — SUB PANEL 30 PV MODULE MAIN SERVICE PANEL EI-Ifi alCorrtraSorNa CLIENT: :. Freedom Solar C-10 982892 Freedom Solar Co 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 Tel: (800) 385-1075 K m 0 D Z 0 INVERTER OUTPUT CONNECTION TO BE INSTALLED AT MAIN SERVICE PANEL ,PER CEC 2016 705.12 (D) MARKING -SHOULD BE PLACED ON ALL INTERIOR AND EXTERIOR PV CONDUIT; RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES, EVERY 10 FEET, AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS AND ALL PV COMBINER AND JUNCTION BOXES. WARNING PHOTOVOLTIC POWER SOURCE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION; TO BE INSTALLED AT DISCONNECTING " MEANS PER CEC 2016 690.17 WARNING ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE, AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. PHOTOVOLTAIC POWER SOURCE SHALL BE LABELED WITH THE FOLLOWING WARNING AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT, AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE PER CEC690.35(F) WARNING ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. BOYD, BRENT & LEANN - BJ151201 15085 MERIDIAN RD, CHICO, CA 95973 (530) 392-6270 WARNING ELECTRIC SHOCK HAZARD •� THE DC CONDUCTORS OF THIS, PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE 690.12 COMPLIANT PHOTOVOLTAIC SYSTEM, EQUIPPED WITH RAPID SHUTDOWN DIRECT-CURRENT PHOTOVOLTAIC POWER SOURCE TO BE INSTALLED AT INVERTER PER CEC 690.53 OPERATING CURRENT: 17.9A OPERATING VOLTAGE: 350.00V SHORT-CIRCUIT CURRENT. 23.62A MAX SYSTEM VOLTAGE: 500.00V AC DISCONNECT. PHOTOVOLTIC DISCONNECT FOR UTILITY OPERATION WARNING ELECTRIC SHOCK HAZARD CONTACT QUALIFIED SERVICE PERSONNEL FOR ASSISTANCE Nominal Voltage 240 Volts Nominal AC Frequency 60 Hz Maximum AC Power 7600 Watts Maximum AC Current 40.00 Amps Max.Overcurrent Device 40 Amps Max. Current per Pole 40.00 Amps REVISIONS: DESCRIPTION DATE I REVISION TITLE: DATE: 10/04/2017 DESIGN GREG BY: LABELS JOB NO.: FS -10-015 SHEET: PV -5 CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING I WARNING dS SOURCES WITH DISCONNECTS LOCATED AS SHOWN TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL AC DISCONNECT INVERTER EQUIPPED WITH RAPID SHUTDOWN JUNCTION BOX — SUB PANEL 30 PV MODULE MAIN SERVICE PANEL EI-Ifi alCorrtraSorNa CLIENT: :. Freedom Solar C-10 982892 Freedom Solar Co 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 Tel: (800) 385-1075 K m 0 D Z 0 INVERTER OUTPUT CONNECTION TO BE INSTALLED AT MAIN SERVICE PANEL ,PER CEC 2016 705.12 (D) MARKING -SHOULD BE PLACED ON ALL INTERIOR AND EXTERIOR PV CONDUIT; RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES, EVERY 10 FEET, AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS AND ALL PV COMBINER AND JUNCTION BOXES. WARNING PHOTOVOLTIC POWER SOURCE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION; TO BE INSTALLED AT DISCONNECTING " MEANS PER CEC 2016 690.17 WARNING ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE, AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. PHOTOVOLTAIC POWER SOURCE SHALL BE LABELED WITH THE FOLLOWING WARNING AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT, AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE PER CEC690.35(F) WARNING ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. BOYD, BRENT & LEANN - BJ151201 15085 MERIDIAN RD, CHICO, CA 95973 (530) 392-6270 WARNING ELECTRIC SHOCK HAZARD •� THE DC CONDUCTORS OF THIS, PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE 690.12 COMPLIANT PHOTOVOLTAIC SYSTEM, EQUIPPED WITH RAPID SHUTDOWN DIRECT-CURRENT PHOTOVOLTAIC POWER SOURCE TO BE INSTALLED AT INVERTER PER CEC 690.53 OPERATING CURRENT: 17.9A OPERATING VOLTAGE: 350.00V SHORT-CIRCUIT CURRENT. 23.62A MAX SYSTEM VOLTAGE: 500.00V AC DISCONNECT. PHOTOVOLTIC DISCONNECT FOR UTILITY OPERATION WARNING ELECTRIC SHOCK HAZARD CONTACT QUALIFIED SERVICE PERSONNEL FOR ASSISTANCE Nominal Voltage 240 Volts Nominal AC Frequency 60 Hz Maximum AC Power 7600 Watts Maximum AC Current 40.00 Amps Max.Overcurrent Device 40 Amps Max. Current per Pole 40.00 Amps REVISIONS: DESCRIPTION DATE I REVISION TITLE: DATE: 10/04/2017 DESIGN GREG BY: LABELS JOB NO.: FS -10-015 SHEET: PV -5 °sem •' �r - t - ., - r 'i , .- ' _ - e .+. `�f• 1, r .. - ` `ENGINEERING DRAWING (mm)` ALL-BLACK CS6K-280M / I-V CURVES �r CanadianSolar s x , -s' 'Rear View Frame Cross Section A-A ,o. _., _- ,o.._ teo� - 9. _ 9- -_ - - A ':y ' 3. L % • 1 \g-74x:9, n , L net•.- 66 .-- a mo.ming - <�. . • , e, .r t w ; ^ r - i , t v,� i .. t ' 3 3•- __._._ - - 'y4 .L _I P' Mounting Hole--- r o v o t, ' •- - - ^ ' - '- - - -' -' 0 25 30 35 40 15 30 35 r ` 5'1 t5 '20 � - ( .. � 5 t 0 20 25 40 6-05 Gng t [�' vI ` J ■ 1000 W/m! 7r Hok ti 1' _ , ■ ' 800 W/m2 f i, 25•C ■' ' �`h, \. + ' ♦ . s .. ' ' ` t - �y _ ; • + . + _ �_ _ 400 W/m! 941 J- --t..� ■ 600 w/m' , .r r �I 45°C ■ / ■ , ~ 65'C ■ / - ALL-BLACK , Lqp _ r { 6 ! CS6K-270'12751 280M _ . + ' - ¢ � ' r'f. '' .ELECTRICAL DATA STC* MECHANICALDATA All-Black CS6K ' 270M 275M 280M . ` Specification Data r Canadian Solar's ALL-BLACK CS6K-M modules are t Nominal Max. Power (Pmax) •1 270 W 275 W 280 W Cell Type Mono-crystalline, 6 inch '- equipped with dark mono-crystalline cells, a dark R 4" Opt. Operating Voltage (Vmp) 31.1 V °-!31.3 V 31.5 V Cell Arrangement 60 (6 X10) colored backsheet and a black frame for enhanced t '� to"4,, ' L. r. Opt. Operating Current (Imp) 8.67 A _ 8.80 A 8.89 A Dimensions 1650x992x40 mm (65.Ox39.1x 1.57 in) , aesthetics and reliable output. This product can iyr - S . •` Open Circuit Voltage (Voc) 38.2 V, 38.3 V . 38.5 V Weight 18.2 kg (40.1 lbs) ! • 4R� °e�.r „ r• i improve the aesthetics of a rooftop. �. - { ,. n ' M r .i r , Short Circuit Current (Isc) 9.19 A 9.31 A 9.43 A ' Front Cover 3.2 mm tempered glass - Module Efficiency 16.50% 16.80% 17.11% ,Frame Material Anodized aluminium alloy 1 Operating Temperature -40°C - +85°C J-Box IP67, 3'diodes T KEY FEATURES ? linear power output warranty . ' > - . • -! ` 1 Max. System Voltage 1000 V (IEC) or 1000 V (UL) Cable _ 4 mm2 (IEC) or4 mm2 & 12 AWG. _ a Module Fire Performance TYPE 1 (UL 1703) or 1000V(UL),1000 mm (39.4 in) t ' ` 'A • Excellent module efficiency of CLASS C (IEC 61730) = Connectors •T4 series or PV2 series - ^ .�' � r _ : ` 1 ' " • + up to 17.11 % �Q product warranty on materials Max. Series Fuse Rating 15 A Per Pallet 26 pieces, 520 kg (1146.4 lbs) { years and workmanship "' ; , - Application Classification • Class A - Per Container (40' HQ) 728 pieces r Power Tolerance 05W CD Outstanding low irradiance '"°..................................................... �..................................................... ... 'Under Standard Test Conditions (STC) of irradiance of 1000 W/m2, spectrum AM ,° •' - - � • , performance of up to 96.5% y' R 1.5 and cell temperature of 25°c f t MANAGEMENT SYSTEM CERTIFICATES* " �• _ TEMPERATURE CHARACTERISTICS - /� ISO 9001:2008 / Quality management system +' ` * ELECTRICAL DATA �'NOCT* Specification f Data, _ ^J1�` IP67 junction box for long-term 'ISO 14001:2004/ Standards for environmental management system All-Black CS6K - . 270M 275M .280M Temperature Coefficient (Pmax) -0.41 % /'C ^ . - IP67 weather endurance - - OHSAS 18001:2007 / International standards for occupational health and safety , Nominal Max. Power (Pmax) 195 W 199 W 202 W Temperature Coefficient (Voc)- -0.31 % /°C " " "'Opt: Operating Voltage (Vmp) 28.4 V . 28.5 V '28.7 V Temperature Coefficient (Isc) 0.053 % /°C PRODUCT CERTIFICATES* Opt. Operating Current (Imp) 6.87 A 6.95 A 7.04 A Nominal Operating Cell Temperature 45±2 °C k** Heavy snow load up to 6000 Pa, M wind load up to 4000 Pa *'. „ IEC 61215 / IEC 61730: VDE / CE / MCS / CEC AU k Open Circuit Voltage (Voc) 35.0 V . 35.1 V 35.3 V + . ` UL 1703 / IEC 61215 performance: CEC listed (US) / Short Circuit Current (Isc) 7.44 A - 7.54 A. • 7.63 A 4 ' UL 1703: CSA , r • Under Nominal Operating Cell Temperature (NOC ), irradiance of 800 W/m2, - Take-e-Way, spectrum AM 1.5, ambient temperature 20'C, wind speed 1 m/s. ' - ; • s • ' ce PERFORMANCE AT LOW IRRADIANCE, PARTNER SECTION r . r DVE 0 SPus \ nKs BBAV �e� - ®., CERT-. _ } . I' r .............................................. - . Outstanding performance at low irradiance, with an ' "'.................................................. ' * As there are different certification requirements in different markets, please contact average relative efficiency of 96.5 %from irradiances, • T ' your local Canadian Solar sales representative for the specific certificates applicable to. ' y the products in the region in which the products are to be used. between 1.000 W/m2 and 200 W/m2 (AM 1.5, 25°C). .......................................................................................................................... - CANADIAN SOLAR INC. Is Committed to providing high quality ' The specification and key features described in this datasheet may deviate Blighty solar products, solar System solutions and services to customers and are not guaranteed. Due to on-going innovation, research and product enhancement Canadian Solar Inc. reserves the right to make any adjustment around the world. As a leading PV project developer and to the information described herein at any time without notice. Please always , manufacturer_ of solar modules with over 17 GW de to ed around .obtain the most recent version of the datasheet which shall be duly Incorporated • _ ..p y into the binding contract made by the parties governing all transactions related , the world since 2001, Canadian Solar Inc. (NASDAQ: CSIQ) is one of [o the purchase and sale of the products described herein. r the most bankable solar companies worldwide. caution: For professional use only. The installation and handling of PV modules requires professional skills and should only be performed by qualified professionals. . : ♦ ' Please read the safety and installation instructions before using the modules. i.......................................................................................................... r - -For detail information, please refer to Installation Manual. ^ r' CANADIAN SOLAR INC. - - z CANADIAN SOLAR INC. Dec. 2016. All rights reserved, PV Module Product Datasheet V5.531-EN 545 Speedv_ale Avenue West, Guelph, Ontario N1 K 1 E6, Canada, www.ca6adiansolar.com, support@canadiansolar.com , . solar=@s �- . - • SolarEdge Single Phase Inverters for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / SE760OH-US a ntY m oW O` i` Optimized installation with HD -Wave technology - Record-breaking efficiency ` Integrated arc fault protection for NEC 201.1 690.11 and integrated rapid shutdown for NEC 2014 690:12' Extremely smal 4 High reliability without any electrolytic capacitors t lihll�llll/�� Built-in module -level monitoring — Outdoor and indoor installation •Wa'Ve — Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) Optional: Self -Sustaining Power - produce up to 1.5kW directly from PV during grid failure USA -CANADA -GERMANY -ITALY -FRANCE -JAPAN -CHINA -AUSTRALIA -THE NETHERLANDS -UK -ISRAEL -TURKEY -SOUTH AFRICA -BULGARIA www.solaredge.us r solar- • • z - Single Phase Inverters'for North America 1 SE3000H-US / SE380OH-US / SE5000H-US / SE OM-= SE760OH-US SE3000H-US SE380OH-US SE5000H-US SE6000H-US SE7600H US JOUTPUT Rated AC Power Output ......................................3000 3000 . 5000 6000 7600 ...... ................... ...........0 ...... ................... ................... VA ............ Max. AC Power Output ..................................................... 3000 3800 50006000 7600 ................... ................... ................... ................... ..... VA y AC Output Voltage Min: Nom: Max. (183 - 208 - 229) ............................................................................................................................................................. ✓ .... Vac AC Output Voltage Min. -Nom. -Max. (211- 240- 264) ✓ ✓ ✓ ✓ ✓ ............... • Vac ............................................................... AC Frequency (Nominal) 59.3 : 60 - 60.5111 ... Hz Maximum Continuous Output Current 208.V ....a.i................................................................... . 24 ................... .. A - Maximum Continuous Output Current 240V 12.5 16 21 25 32 ................... . A GFDI Threshold 1 A ", , . Utility Monitoring, Islanding Protection, 'Yes Country Configurable Thresholds ` JINPUT Maximum DC Power , 4650 5900 7750 9300 11800 W Transformer -less Ungrounded ...................:............................................................................................................... Yes Maximum Input Voltage ...................................................................................................................................... 480 ' . Vdc Nominal DC Input Voltage ................... 380 400 ........ Vdc Maximum Input Current 208V . ................................... .................................... . 15:5 Adc Maximum Input 240V .... . .. ... .. ............. ......... 8;5 10.5 1315.......165 20 Adc Max. Input Short Circuit Current ................................................... ... 45 Ad Reverse -Polarity Protection ............................................................................................................... Yes Ground -Fault Isolation Detection .......................................................... Y ........................................ 600ku Sensitivity ............ Maximum Inverter Efficiency .................. 99 I. i 99.2 ............................................................................ % CEC Weighted Efficiency .......................p............................................................................................................................... 99 ............ % Nighttime Power Consumption g < 2.5 .........:.. W SELF SUSTAINING POWER OUTLET.(OPTIONAL)"- ' `3 - t .I ``-{ r •`wri A t -' + y:_ ' ! ;!! , +' ' t Nominal Output Voltage .................P...........................................................................................131 120 ............................................. V' Maximum Output Power ............................................................................................................................................................ 1500 ..... W External Outlet with GFDI Yes ............ ;ADDITIONALFEATURESr G. a Z, Supported Communication Interfaces ........ .... ......... ........ ......... R5485 Ethernet ZlgBee (optional) Cellular.(optional) .................. Internal RGM support ANSI C12.20 class 0.5 compliant Rapid Shutdown - NEC 2014 690.12 Automatic Rapid Shutdown fSTANDARD COMPLIANCE :'i. f -'a r.c T ' )Y. ' f a . - 4, pj .. ._ ,. Safety ............. ... UL3741, UL1699B, CSA C22.2:CanadianAFCIaccordingtoT.I.L.M 07........w.. ... ...... ............ Grid Connection Standards 7, Rule 21, Rule14 (HI) Emissions FCC Part 15 Class B INSTALLATION'SPECIFICATIONS AC Output Conduit Size /AWG Range .......................................................•.........'........................................................................................ 0.75-1" Conduit/ 14-6 AWG ............ DC Input Conduit Size / It of Strings / AWG Range ......................................... 0:75.1" Conduit /1-2 strings/ 14-6 AWG' ........................................................... ............ Dimensions with Safety Switch (HxWxD) ....................................................................................................................................................... 17.7 x 14.6 x 6.8 / 450 x.370 x. 174 in/mm ............ Weight with.Safety.Switch ......................................................................................................................................... 2.5...3./.1.1..5 lb ./ kg Noise I < 25 dBA Cooling ................................................................................. Natural Convection ..........................131._............................................ Operating Temperature Range ................................................................................................................................ -13 to +140 / 25 to +60 (40•F / 40'C option) ............ 'F / -C ............ Protection Rating ................................................. NEMA 3R (Inverter with Safety Switch) .................................................................. ............ 111 For other regional settings please contact SolarEdge support - ^ 1`1 Depends on PV availability 111 Power de -rating from 50'C . , - • solar =oo .. : SolarEdge Power Optimizer Module Add -On For North America r P300 / P320 / P400 / P405 PV power optimization at the module -level Up to 25% more energy Superior efficiency (99.5%) - `— ,Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading - Flexible system design for maximum space` utilization ' — Fast installation with a single bolt - Next generation maintenance with module -level monitoring Module -level voltage shutdown for installer and firefighter safety USA - CANADA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - AUSTRALIA - THE NETHERLANDS- UK - ISRAEL - TURKEY - SOUTH AFRICA - BULGARIA www.solaredge.us • ' i. .' • r r - . i - ' so l a r- o o SolarEdge Power Optimizer'- Module Add -On for North America - P300 / P320 / P400 / P405 • . E - ' ' P320 P400 P405 ` TP300 (for 60 -cell modules) (for high-power (for 72 & 96 cell (for thin film 60 cell modules) modules) modules) _ J.INPUT Rated Input DC Powerft! 300 320 ............ 400 405 Absolute Maximum Input Voltage ........... .... . ............ .....W ..... ' a (VOC at lowest temperature) . . 48 80 125 Vdc MPPT Operating Ran.�e 8-48 48 g:.8.0.......... :...... 12.5 - 105.:..:.. Vdc.... ................ Maximum Short Circuit Current (Isc)_. ..................................... ........................ . ........................... .......... ' . 10 - 11 10.1 • `.................................... .... . Adc * 4 ..Maximum DC Input Current ......... 12.5 ..........13:75 .......... ..................... ... 12:63..,.,........... _....... .. .. ...,Adc .... Maximum Efficiency99.5 ............................................ .....................................:.......................................................................... % ............. '• Weighted Efficient y 98.8 ................................................................f.............................................. "/0 Overvoltage Category II . ( OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) .. •^ . ' Maximum Output Current 15 ... Adc ............. Maximum Output Voltage 60 85 Vdc ,!OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) - Safety Output Voltage per Power • Optimizer - 1 ' Vdc - isTANDARD COMPLIANCE., EMCFCC + Part15 Class B, IEC61000-6-2, IEC61000-6-3 .................. Safety .............................................................................................. ................. IEC62109-1 (class II safety), UL1741 ............ ROHS _ Yes f INSTALLATION SPECIFICATIONS ; .._ • +.' ;:'_ ?- i i Maximum Allowed System Voltage 1000 • .................................................... Vdc Compatible inverters . All SolarEdge Single Phase and Three Phase inverters . Dimensions(WxLxH) 128x152x27.5/ 128x152 x35/ 128x152x50/ mm/in 5x5.97x1.08 5x5.97x1.37 5x5.97x1.96 Weight (including cables) 630 / 1.4 .....750/1.7. 845 .................................... ............. gr / Ib Input Connector MC4 Compatible ..... ............................. .......... Output Wlre .Type / Connector .............. Double Insulated; MC4 Compatible ........................................ .......... ...m/ft Out ut Wire Len h p .......... ... .................... 0. 3. 95 / 0 I.. 1.2 / 3.9 .. / ft ............. 'Operating Temperature Range :40:+85/.40-+185 .............................................. • 'C/'F ' .. ...... Protection Rating ............................................ IP68 / NEMAISP .........................................................................................................I..... ......p/....... Relative Humidity ........... 0-100 ............................................................................................................... % .. to Rated STC power of the module. Module of up to +S% power tolerance allowed. - SYSTEM DESIGN USING iPV SINGLE PHASE THREE PHASE 208V THREE PHASE 480V� A SOLAREDGE INVERTERI2� + Minimum String Length Power 0 ttmizers 8 10. 18 Maximum String Length 25 25 50 (Power Optimizers) .................................................. I.... .............................. ................ ............ .... ........... Maximum Power per String ........... ...............5250 6000 12750 W ..... ............... ............... ............. .... . Parallel Strings of Different Lengths Yes or Orientations ............................................ ........................................................................................................... ............ . I:1 It is not allowed to mix P405 with P300/P400/P600/P700 in one string. CE �� © SolarEdge ZTechnologies. Inc. All rights reserved. SOLAREDGE. the SolarEdge logo, OPTIMIZED BY`OLAREDGE aretrademarks or registered trademarks oI 6larEdge Technologies Ino All other trademarks mentioned herein are trademarks of their respective owners7 Date: 01%2017 V011Subject t0 change without notice. i. IRONRIDGE .`-flush Mount=System XR Rails ; i' i•' - s• ' 's XR10 Rail - XR100 Rail 1 XR1000 Rail - 'Bonded Splices • - - i • .. - r 1 - ^ - - � r + ' - _• � � F_ • ry '•x^ t:s . � • �' � � y ,�.^,f..Z, k an'ti,� - . y-��,,.'�y �' .. y A low -profile mounting rail,', The ultimate residential. A heavyweight mounting • All rails use internal splices • t �' 4 ' ` _ �- + for regions with light snow. solar mounting rail. ♦ rail for commercial projects. for seamless connections. 6' spanning capability 8' spanning capability 12' spanning capability Self -drilling screws Moderate load capability Heavy load capability Extreme' load capability Varying versions for rails s Clear &black anod. finish Clear &black anod. finish ,� CI 'ar'anodized finish'-* Forms secure bonding - ` Clamps � Grounding O y r � � ." � ter. �. 1 � ♦ .. ` .. s' ... '., ` - z. •- t - .. ` �F • , ; -T-- - UFOs 9 -Stopper Sleeves - Grounding Lugs Microinverter Kits _r ,ir�.Y_.. ♦ r _ --- Universal Fastening Objects Snap onto the UFO to turn • Connect arrays to _, Mount MIs or POs to XR • ; ♦ -� —"�' ; r� # ;bond modules to rails. ,into a bonded end clamp. equipment ground. 4 `Rails. • • Fully assembled & lubed Bonds modules to rails Low profile '; Bonds devices to rails • -Single, universal size 6 different sizes ' •Single tool installation Kit comes assembled • r . '< = •Clear,& black finish, Clear &black anod. finish •Mounts in any direction Listed to UL 2703 ' Built for solar's toughest'roofs. r • Attachments O IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to _ • F ' ' the limit and proven in extreme environments. • _ FlashFoot2 " Slotted L -Feet Bonding Hardware Flush Standoffs Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and w > is also why our products are fully certified, code compliant and backed by a 20 -year warranty. • - - ' ... r � to _ 1 k� . s = ` • l� , vul Strength Tested PE Certified Y �� L All components evaluated for superior ® Pre -stamped, engineering letters - �. Flash and mount XR Rails Drop-in design for rapid rail Bond and attach XR Rails Raise Flush Mount System structural performance. available in most states. with superior waterproofing.. attachment. � to certified attachments. to various heights. r Twist -on Cap eases'install Secure rail connections' T & Square Bolt options e -Works with vent flashing ` Wind -driven rain tested Slot for vertical adjusting Nut uses 7/16" socket 4" and 7" lengths ` Class A Fire Rating- - Design Assistant t . Mill & black finish •Clear &black anod. finish • Assembled & lubricated • Ships assembled Certified to -maintain the fire resistance ® Online software makes it simple to Resources . rating of the existing roof. • create, share, and price projects. _ Design Assistant NABCEP Certified Training �St� PAY UL 2703 Listed System 20 -Year Warranty • -- Go from rough layout to fully �' Earn free continuing education credits, : iNABCEP engineered system. For free.- while learning more about our systems. ® Entire system and components meet Twice the protection offered by _ . ! Go to IronRid e.com/desi n Go to IronRid Ridge.com/training effective UL 2703 standard. competitors. -_ 9 g g g 3933 US Route 11 Cortland, NY 13045 Intertek Telephone: (607) 753-6711 Facsimile: (607) 756-9891 www.intertek.com June 20, 2014 Letter Report No. 101703554CRT-001 Project No. G101703554 Mr. Meir Adest Ph: +972.9.957.6620 SolarEdge Technologies Ltd email: meir.a@solaredge.corn 6 Ha'Harash St. HOD HASHARON, ISRAEL Subject: ETL Evaluation of SolarEdge Products to NEC Rapid Shutdown Requirements Dear Mr. Meir Adest, This letter represents the testing results of the below listed products to the requirements contained in the following standards: National Electric Code, 2014, Section 690.12 requirement for rapid shutdown. This investigation was authorized by signed Quote 500534459 dated 06/10/2014. Rapid shutdown test were perform at SolarEdge Technologies Ltd, 6 Ha'Harash St HOD HASHARON, ISRAEL and witness by Intertek personal on 06/17/2014. The evaluation covers installations consisting of optimizers and inverters with part numbers listed below. The testing done has verified that controlled conductors are limited to not more than 30 volts and 240 volt- amperes within 10 seconds of rapid shutdown initiation. Applicable products: • Power optimizers: o PBxxx-yyy-zzzz; where xxx is any number, 0-9, up to a maximum value where xxx = 350; yyy could be AOB or TFI; and zzzz is any combination of four letters and numbers. o OP -XXX -LV, OP -XXX -MV, OP -XXX -IV, OP -XXX -EV; where xxx is any number, 0-9. o Paaa, Pbbb, Pccc, Pddd, Peee; where aaa, bbb, ccc, ddd, eee is any number, 0-9 to a maximum upto" aaa=300, bbb=350 ccc=500, ddd=600, eee=700. o Pxxx, Pyyy, Pzzz, Pmmm, Pnnn and P000; where xxx, yyy, zzz is any number, 0-9 to a maximum up to xxx=300, yyy=350, zzz=500; where mmm, nnn, 000 is any number, 0-9 to a maximum up to mmm=405, nnn=300, 000=350 • 1 -ph Inverters: o SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE7600A-US / SE10000A-US / , SE1140OA-US when the SolarEdge rapid shutdown cable labeled "MCI-CB-xxxxx-x" which is part of kit SE1000-RSD-xx is installed in the inverter Safety Switch where xxxxx-xx is any number; inverter part number may be followed by a suffix Page 1 of 2 This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test resutts in this report are relevant only the sample tested. This report by itself does not imply that the material, product or service is or has ever been under an Intertek certification program. 9EAS Intertek Intertek Intertek Intertek Intertek Intertek Intertek Intertek Testing Services NA, Inc. , SO 12.1.2 (11/11/10) Informative SolarEdge Technologies Ltd Letter Report 101703554CRT-001 June 201h, 2014 • 3 -ph Inverters: o SE9KUS / SE10KUS / SE20KUS when the SolarEdge rapid shutdown cable labeled "MCI-CB-xxxxx- x" which is part of kit SE1000-RSD-xx is installed in the inverter Safety Switch where xxxxx-xx is any number; inverter part number may be followed by a suffix This letter report completes this portion of the evaluation covered by Intertek Project No.G101703554. If there. are any questions regarding the results contained in this report, or any of the other services offered by Intertek, please do not hesitate to contact the undersigned. Please note, this Letter Report does not represent authorization for the use of any Intertek certification marks. Completed by: Radhe Patel Reviewed by: Howard Liu Title: Engineering Team Lead Title: Staff Engineer Signature: — — Signature Date June 201n, 2014 Date: June 20 , 2014 Intertek Testing Services NA, Inc. Page 2 of 2 So 12.1.2 (11/11/10) Informative _ CLASSIFICATION Constructional Data Report (CDR) 1.0 :Reference and Address- F . t"'� � � � � °.�:,-r' �'�i��."At'- ,--,-„,.;,�±n'�.�, •ter :�""s", ..�'`.� r `���;�:ir�; Re ort�Numbe�, 101541132LAX-oo2 Original 22 -Ma -2014 Revised: 15 -Jan -2016 tp.' UL Subject 2703 Outline of Investigation for Rack Mounting Systems and Clamping Devices Standard(s); '.' h t a for Flat -Plate Photovoltaic Modules and Panels, Issue Number: 1, October 4, 2010- r� rtµr The product covered by this report is the IronRidge Rails with Integrated Grounding solar roof IronRidge, Inc. s.Mariufacturer 1� IronRidge, Inc. _V r^ w Address ' . ' 1495 Zephyr Ave _ A Address le 1495 Zephyr Ave - Hayward, CA 94544 r,,{ ,�.,-,: Hayward, CA 94544 Count t,• 'USA A grounding strap and stainless steel hardware are required for penetrating the anodized F, 'Count "'r v USA Mid Clamp and aluminum End Clamps are used to attach and support framed photovoltaic Jim NorsworthyOr T ,`Contact;" Yann SchwarzContact] `` ”' The Grounding Mid Clamps are installed onto the module frame by using a 18-8 stainless steel , serrated T -Bolt and a 18-8 stainless steel Flange Hex Nut that gets screwed onto the rails to a specified torque. The retention teeth of the clamp and bolt penetrate the anodized coating of �.; Dave Taggart Z Phone (800) 227-9523„� Phoney". (707) 363-3025 v v , (510) 225-0973 s,; (800) 227-9523 FAX ' `: 707 459-1833 FAX';z!-,-.(510) 225-0975 4� -°-t N ', $r., Ei yschwarzCcDironridge.com 4 x t�..,, + " ' Email : jnorsworthvCcDironridge.com i. 7� - �N :, • manufacture's specified torque. The WEEB Grounding Lug is intended for use with one solid or .. : „ .�: dta artironrid e.com Mariufacturer-2. Precision Die & Stamping, Inc. ,�. = ss e Address':. 1704 W. 10th Street � ; ;_�j „ -;_4� Tempe, AZ�85281 - , m r 4 Codnt ,. USA Contact .� $, And Frola . ` Fuse Rating: 20 A r 'Phone k (480) 967-2038 - Class A for Steep Slope Flush -Mount (Symmetrical) Applications when using Type 1, 1. Type 2 and Type 3, Listed Photovoltaic Module. :FAX .,, . -', (480) 829-0838 } Email andyCa�orecisiondie.com Class A for Steep Slope Tilt -Mount ( Asymmetrical) Applications when using Type 1 i 4 Page 1 of 86 This report is for the exclusive use of Intertek'sClient and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any parry, other than to the Client in accordance with the agreement, for any loss• expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Report No. 101541132LAX-002 ' IronRidge, Inc. r . Page 2 of 86 Issued: 22 -May -2014 Revised: 15=Jan-2016 2.0.'Product`Descri tion nws °x w,+ Product; y. cc: a XR Rails with Integrated Grounding. Brand name;.`' IronRidge Roof Mount r� rtµr The product covered by this report is the IronRidge Rails with Integrated Grounding solar roof mounting system. This system is designed to provide bonding and grounding to photovoltaic {� f modules. The mounting system employs anodized aluminum rails that are roof mounted using • . Y aluminum Extruded L Foot brackets. The mounting rails in this report are XRL, XR10, XR100 :w. and XR1000 Rail. All rails have an optional aluminum splice which ties the rails together to ;$r extend their length. t , A grounding strap and stainless steel hardware are required for penetrating the anodized coating of the rails, creating a bonded connection from rail to rail. 304 stainless steel Grounding Mid Clamp and aluminum End Clamps are used to attach and support framed photovoltaic modules to the systema The End Clamps are not used as a grounding means. `` ”' The Grounding Mid Clamps are installed onto the module frame by using a 18-8 stainless steel Description*1, serrated T -Bolt and a 18-8 stainless steel Flange Hex Nut that gets screwed onto the rails to a specified torque. The retention teeth of the clamp and bolt penetrate the anodized coating of the photovoltaic modules frame and rail to contact the metal, creating a bonded connection from module to module and module to rail. . �za The grounding of the entire system is intended to be in accordance with the latest edition of the National Electrical Code, including NEC 250: Grounding and Bonding, and NEC 690: Solar 9 9 9, M Photovoltaic Systems. Any local electrical codes must be adhered in addition to the -- t N national electrical codes. An entire array, regardless of size, is grounded via one'grounding tZ ” lug. The WEEB Grounding Lug is secured to XRL, XR10, XR100 or XR1000 Rail's top slot using stainless steel hex bolt or T -Bolt, flat washer, split lock washer' and nut, tightened to manufacture's specified torque. The WEEB Grounding Lug is intended for use with one solid or T : stranded copper wire, conductor size 14 AWG though 6 AWG. The Titan Grounding Lug is secured to XRL, XR10, XR100 or XR1000 Rail's side center cavity of rails using stainless steel ,�. T -bolt, k -lock nut, star washer, and machine screw. The Titan Grounding Lug is intended for '�*:-,.�• use with one solid or stranded copper wire, conductor size 14 AWG though 4 AWG. Models xv".` i IR XR followed by 4 Alphanumeric Characters 'Model°`Similarity;, N/A z~- `! Fuse Rating: 20 A 1 d'` '`t Fire Class Resistance Rating: - Class A for Steep Slope Flush -Mount (Symmetrical) Applications when using Type 1, 1. Type 2 and Type 3, Listed Photovoltaic Module. ` F2atrngs;�L Y - Class A for Low Slope Flush -Mount (Symmetrical) Applications when using Type 1, Type t and yp Type 3, Listed Photovoltaic Module. Class A for Steep Slope Tilt -Mount ( Asymmetrical) Applications when using Type 1 i 4 and Type 2, Listed Photovoltaic Module. Class A for Low Slope Tilt -Mount ( Asymmetrical) Applications when using Type 1, �`y L Type 2 and Type 3, Listed Photovoltaic Module. ED 16.3.15 (1Jan-13) Mandatory 25800 Commercentre Drive Lake Forest, CA 92630 USA Telephone: 949.448.4100 Facsimile: 949.448.4111 www.intertek.com Test Verification of Conformity In'the basis Of' the tests undertaken, the sample(s) of the,below product have been found to comply with the requirements of'i the.referenced specifications at the time thelestswere carried out:. This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. GFT -OP -11 a (24 -MAR -2014) rAppfican�N,an e &Address: IronRidge, Inch. , 1495 Zephyr'Ave. .. , Hayward; CA 94544 _ f Product Description: .XR Rails'With'Integrated Grounding. >. r Ratings & Principle Fire'Class Resistance Rating:' Characteristics: - Class A for Steep Slope;Flush=Mount (symmetrical) Applications when,usng Type 1 arid. • 2, tisted.Photovoi-t aic�Mo'dule. - e .,.Type .. , - Class A for Low Slope Flush -Mount. and Tilt -Mount (symmetrical:and asymmetrical) Applications when using Type.1, Listed Photovoltaic.IVlodule. Models: , 51-61GD=005, 51-61GD-0056; 51-5000-001-; and 51-65=001 BrandName: N/A. , Relevant Standards: UL Subject 2703 (Section 15.2 and 15.3) Outline of Investigation for Rack_Mounting Systems and Clamping Devices for'Fiat=Plate Photovoltaic" Modules and Panels, Issue-N'umber:'2,,Nov 13,2012'" ".` Referencing UL1703 (Section 31:2) Standard for Safety for FIat 131" —Photovoltaic Modules and - Panels, -May 20,2014 { --( Intertek Testing Services NA,`Inc.° e ; Verification Issuing_Office • 25800•Commercentre Dr:1 Lake Forest, CA 92630 .., Date of Tests:. ,08/_27/2014 to 01/,07/2015,, s ' Test Report Number(s)- '101541132LAX=002 This verification is part of the full test report(s)`and should be read in conjunction with them. This report.does not automatically imply product certification., w , Corn pleted by: ` Amar KaceI' ;� ,Reviewed by:,., Andrew'Koretoff - Title: PV Engineer - Title: Reviewer ;. Signature: ; _ --.' _ Signature:,— r _ Date: 01/26/2015 Date:, 01/26/2015 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. GFT -OP -11 a (24 -MAR -2014)