HomeMy WebLinkAboutB17-2497 039-570-039BUTTE COUNTY
DEPARTMENT, OF DEVELOPMENT SERVICES
INSPECTION CARD. MUST BE ON JOB SITE
24 Hour Inspection Line (IVR) : 530.538.4365 (Cut time for inspections is 3pm)
Development Services cannot gt
guarantee inspections on the date requested
-Otfice:530.538.7601 Fax: 530
Permit No: B 17-2497 ' Issued: 10/23/2017 .
APN: 039-570-039
Address: 2880 CHICO RIVER RD, CHICO -
,Owner: DAVIS FAMILY TRUST
Permit Type: SOLAR ROOF -RES
Description: 12.24KWDC Shop roof mount solar system
Asa. i i63 www.butte
Flood Zone: None
ty.nevaas
SRA Area:
or Zoning. AGP S
Front: 'Centerline of Road:
Rear: SRA:
Street: AG:
Interior
Total Setback from Centerline of Road:
AREA
5'
No
ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING
1. .
Inspection Type
IVR INSP DATE'
Setbacks
131
Foundations / Footings
111
Pier/Column Footings
122
Eufer Ground
216
Masonry Grout
120
Setbacks
131
Do Not Pour Concrete Until Above are Sign d
Pre -Slab
124 '
Gas Test Underground/floor
404
Gas Piping Underground/floor
403
Underfloor Framing
149 .
Underfloor Ducts
319
Shear Transfer
136
Under Floor Plumbing
412
Under Slab Plumbing
411 "
Blockin /Under inin
612
Tiedown/Soft Set System
611
Do Not Install Floor Sheathing
or. Slab Until Above Signed
ShearwallB.W.P.-Interior
134
ShearwallB.W.P.-Exterior
135
Roof Nail/Drag Trusses
129
Manometer Test
605
Do Not Install Siding/Stucco or Roofing Until Above Signed
Rough Framing
153
Rough Plumbing
406
Rough Mechanical
316
Rough Electrical
208
4 -Way Rough Framing
128
Gas Piping House
403
Gas Test House
404
Shower Pan/Tub Test
408
Do Not Insulate Until Above Signed
Permit Final
802 v
Electrical Final
803
Mechanical Final
809
Plumbing Final
813
Fire Sprinkler Test or Final
702
Swimming
Pools
Inspection Type
IVR INSP DATE
T -Bar Ceiling
145
Stucco Lath
142
Swimming
Pools
Setbacks
131
Pool Plumbing Test
504
Gas Test
404
Pre-Gunite
506
Pre -Deck
505
Pool Fencing/Alarms/Barriers
503
Pre -Plaster
507
Manufactured Homes
Setbacks
131
Blockin /Under inin
612
Tiedown/Soft Set System
611
Permanent Foundation System
613
Underground Electric
218
Sewer
407
Underground Water
417
Manometer Test
605
Continuity Test
602
Skirting/Ste s/Landin s
610
Coach Info
Manufactures Name:
Date of Manufacture:
Model Name/Number:
Serial.Numbers:
Len th x Width:
]nsionia:
Public Works Final 538.7681
Fire De artment/CDF 538.6226
Env. Health Final 538.7281
Sewer District Final
PROJECT FINAL 1 O 29
*Project Final is a Certificate of Occupancy for (Residential nly)
PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF NVORK HAS COMMENCED, YOU MAY PAY FOR A I YEAR
RENEWAL 30 DAYS PRIOR TO EXPIRATION
1•�1 „: B� '•e eek e
' •CPl '131• �"). �I e • e ^
' O . g , a
"PO.INT�OF LATER 0 NEC ON AC WA NINGI�ABEL�'
�t/.,�c.,•.a�.s•.fi,.-,sw..,z'�,'.�'r.s�+a..�'�t,rr•' Ja3"r'aaf sraui :':o 'vn,:>rr'a.2a�"�.-''•,�`P`'.,.� `.�, ,
r'f<'
t
i .S.
.:,..,,, ,,.,_ ,.r...a;�..•.,.-:,.: MOUNT ON MAIN SERVICE A EL:O
., i .. ^...i .. .. .:.... ......: ..l .. _ + -r.:..:..:.:i�n<�'•. �: ;:�•n .',^,-i i,�tI+"
id n
'r:<•1NHITE TEXT RED BACKGROUND ENGRAVED PLACARD' �'_-�;��:��g
..t.r Y _w11 �.4'•;i- ::'aE,:,�-i1''..^ j!y;:'v. .
,....,- � . a, .. � .•,,,,., 16.18 t LETTERING„ ..r::
1
;r
'fir ,' ' U�1 ' •Cl�l 'Q��i, �+'�(�11� ' e • � e -
flQ�3�IC1��®��' • • h�:
-
r BPANELP�INT OF INTERCONNECTION LA�BEL�
nom.,
5�?xz
.q., ,:=;M ors'.:
W'. :r';" +,. G•`.. .`.;`. C,�r' :-
a:e �``',
yr
OUNTON<NIAIN° ERVICEPANEL
-M S - •' z
<.�.:: is
rY —
4
1,<......:,... WMITE':TEXT :RED:BACKGROUNMENGRAVED:PLACARD
,..:_ -
a�.
.53
t::LETTERING.._..:�' �.'�^ _ :;�:;,��
J /
r.
IONv O R CIRC ITS ARNINL _
CAUT l
dr'r°Y+flt4;.;`rsri..�a',.-.e-'aae:Yvhp&:a'?..:s-s','.P>rys.Yr..s..5i?'3:aw.rir.r��''f�'r'�a,,8;?`:?>�.,
.. �:: ....:r •t. , r..
- ..... .... -::_! .. •, .. .r -:fit+•,..,.. ..:,. ..: �,.,.-._., �... .r: f. ..., ..:.._,,. ">`1 :S`:
'%K:c'
WMITE:,TEXT:RE -BACKGROUND =:REf.LECTIVE,STICKER�%,
_ D,
'- - :.. ..........: .. . .1.: t-.:.....:., , _.. ,�- v -. � _M.. ..r,., r.;.--... ...;.., .:':.... =r'`.e mss. ,r •�: - 6,
,t.mac •'-
t.LETT:ERiNG.
1
J
SUNNY BOY
3.0 -US / 3.8 -US / 5.0 -US / 6.0 -US / 7.0 -US / 7.7 -US
[ULirLE r_NO('IP1ClUDED;
1
«-�-.- .+.•.»,.�---•�+...a� i
Y Value -Added Improvements Reducedaabar; a ;Unmatched Flextbthty�' -_ Trouble Free-Serncing.
1N64s first Secure.Power Supply `'New)nstallation As;istant wdh a SMA s.propnetary OptlTraeT"� Two part enclosure concept
„now offers up tot 000 W L;i direct access wa smartphone �; Globdl Peak techbology mitigates > allows For simple expedited
' „minrm¢es time in the field ' - shade with ease t? servicing
Full gnd managementcapablllhes i s , ,_ �� r a r v
f
ensures agitycompllant solutiori Integrated_disconnect simplrfie's ; fy Multiple independent MPPTs Enhanced AFCI'.technology reduces '
for any market i°, equipment stockirig find speeds ° i. accommodate hundreds of.'_ } false'tnpping while improving
installafiori stringing possibilities sensitiviy in:reol arcs; greatly
reducing unneeded service calls
SUNNY BOY
3.0 -US / 3.8 -US / 5.0 -US / 6.0 -US / 7.0 -US / 7.7 -US
Reduce costs across your entire residential business'model
The residential PV market is changing rapidly, and we understand that your bottom line matters more than ever. That's
• why we've designed a superior residential solution that will help you decrease costs throughout all stages of your
business operations. The Sunny Boy 3.0-US/3.8-US/5.0-US/6.0-US/7.0-US/7.7-US join the SMA lineup of field -proven
solar technology backed by the world's #1 service team, along with a wealth of improvements. Simple design, improved
stocking and ordering, value driven sales support and streamlined installation are just some of the ways that SMA is
working to help your business operate more efficiently.
Sensor module Uernol WLAN criteono
MD.SEN-USAO EXTANT -US -A6
----------- ----
. . , Preliminary efficiency curve SUNNY BOY 6.0 -ISP -US -40
...... Be N. -220A c? 96
Eta K - 375 V11 2io 4M
Eta (V. -48OV) V_M
0.0 0.2 0.4
i - Ouq
0.6 0.8
Rated power
------- - -----
1.0
208 V 240y
208 240 V
-208V 246 V
Input (DC)
Max. usable 6C pcwey
3100 W. .3 100 W-,
3450 W 3900
5250 W. 5250,W
Max- DC voltage
600 V,
Rated MPP voltage range
155 480 V
.195 - 480 V
220 -,480 V
MPPT operating voltage range
100 - 550 V
Min. DC voltage / start voltage
.10OV/125V
Max. operating input current per MPPT
10A
Max. short circuit current per MPK
18A
Number of MPP` tracker/ string per MPPT tracCer
3/ 1
Output (AC)
AC nominal power
3000 W 3000W.
-3330W 3800 W
5000 W 5000 W
Max. Ac4p-refil power
3060 VA 3006 VA
3330 VA, 3800 VA,
5000 VA 5000 VA
Nominal voltage,/ adjustable
208.V/ 2,40 V, 41
V 2AOV/*
.208 V w 2,46V ) 0
AC voltage range
183 229 V - 2111 -26AV
183 - 229 V 211. - 264 V
183 - 229V 211 264 V
AC grid frequency
60,Hz/50Hz.'
Max. output current
.14.5 A 12.5 A
16.0 A, 16.0 A
24.0 A .2A.0 A
Power factor (cos (p)
Output phases line connections
1/2
Harmonics
Efficiency
Max. efficiency
97:2 % 97.5 %
97.59722
%
% 97.5%
CEC efficiency,
96.5 % 97.0 %.-
.9615 % 97.0 %
96-5 % .97%
Protection devices
DC disconnect device
-
DC reverse polarity protection i r
.7
Ground fault monitoring/ Grid monitoring
AC short circuit protection
Allpole sensitive residual. current monitoring unit (RCMU) i
Arc fault circuit interrupter (AFCI)
•
Protection class ovwvolt.age category
J/ IV
General data
Dimensions (W/H/D)inmm (in)
535 x 730 x 198 (21.1 x 28.5 x 7.8)
Packaging Dimensions (W H D) in mm (in)
600, x 800- x 360 (23.6 x 31.5 x 11.8)..
Weight
26 kg (57 lb)
Packaging weight,
30 kg (66 16),
Operating temperature range
7 25.*C...+60*C
Noise emission (typical)
<25 dB(A)
Internal power consumption at night
< S W
Topology
Transformedess
Coaling concept,
Convection
Features
Secure Power Supply
Display (2 x 16 characters)
Interfaces: Ethernet /.WLAN
Sensor module External MAN antenna'
0/0
Warranty: 10 / 15 / 20 years
9/0/0
Certificates and ipprovals
- UL 1998; 1 UL 1,6998, IEEE 1 . 547, FCC I Part 15 (da -ss A& B), CAN/CSA V22.2 107.1-.1
Ull. - 1741
• Standard features 0 Optional features Not ayaiGble
Data O'Fnominal conditions
NOTE: US inverte�sship With bray lids. " *,Preliminary data, UL pending
Type designation .
SB3.0-1 SP -US -40
SB3.8-I SP-US,40
S85.0-1 SP -US -40
Accessories
Sensor module Uernol WLAN criteono
MD.SEN-USAO EXTANT -US -A6
----------- ----
. . , Preliminary efficiency curve SUNNY BOY 6.0 -ISP -US -40
...... Be N. -220A c? 96
Eta K - 375 V11 2io 4M
Eta (V. -48OV) V_M
0.0 0.2 0.4
i - Ouq
0.6 0.8
Rated power
------- - -----
1.0
SAME NAME, NEW GAME
The Sunny Boy 3.0 -US through 7.7 -US are once again raising the
bar by offering improved performance, enhanced features, and most
importantly, an economical approach to residential solar. Your business
model is a value chain. The new Sunny Boy -US series can help you stay
competitive in an increasingly price sensitive residential market by driving
down costs across all of your business operations.
..Ioav-.:.:,.' �2aoV
208,V .� igoV...loev
V.
Input (DC)
Max usable. DC power
5500 W 6300 W
.' .6900 W, 7350. W
6950.W 81.00 W
Max. DC Voltage _' : '•
600 V
Rated MPP .Voltage range
: 220 -.480 V :..`
245 -480 V _
270 - 480 V
MPPT operating'voltage range ='
r `'
'10550 V
Min. DC'voltage%,start voltage. ::
_
100,)J 25 V :..
Max.,oper6ting inpupcurrent Per MPPT ' ,
10 A.
Max. short.circuitcurrent per MPPT .. .. -
_. ;::':
18:A,
Numberof'MPPTlracker/string,perMPPTtracker;,`-:.
f ..: 3/ 1
Output (AC)
AC nominal'powec' '. ::'.
�5200_W 6000 W
6660 W 7000 W" :`
6660 W 7680 W
Max. AC apparent power . , + ;; ` _
, .'S2OO:YA ,j., 6000 VA ,
. ,- 6660:VA 7000 VA
6660_':VA , 7680 VA
Nomi 14o Cage / adjustoble ; ;;' ;
..268'V)'4 ,' 240 V;/ 6 `'
268 V / �, 240 V /
208 V/ 4k240 V/ 0.:
AC voltage range,::
183;.- 229,V. ' ; •21,1,'-_264V
. ; 183 -229V; .211 -264V..:
183'- 229 V ;,21 1 -:264 V
AC grid frequency- _ : ' M ,:
-
60 Hz / 50 Hz '
lY1ax.'outpuEcurrenh_ ::.:..
25,0 A, 25 Q A ...
..:: : .... .32.0 A 292 A
32.0 A., 32.0.A
. _
::Power factor (cos W)' ...
1 .:
Output phases./ line ,connections, , -= •
:
1 / 2
Harmonic
__
.. <'4
Efficiency
Max. efficiency l -
97,2 % 97:6 ..:;
7 1 % %'
. ,. 9. • _ 97.2
7 1 %' 97;2 % + .
9 ,
CEC,efficienry . `' :: .. ::'. ..
96:5 °/ .: 97:% _
.. - 96:51% 96:5 %'
96:5 %' .'. 96.
Protection devices
DC disconnect device , " ,
u
DC reverse polarity, protection
: .
Ground Fault monitoring / Grid.monitonng.,'!,
AC short circuit protection
AA
.Pole sensitive residupI current monitoring unit (RCMU)
Arc fault circuit interrupter'(AFCI):
Trotection class / overvoltage cote9ory-4
General data
Dimensions (W / H.% D) in mm. (in)
535 it 730 x 198 (21.1 x'28.5,x 7.8)
Packaging Dimensions f W / H f D) in mm (in)v
600-x 800 x 300 (23.6 x 31.5 x 1 1 8) :,
:- :.'Weight'' _:
.'
26 kg (57 Ib)
P9ckagtng weight
30 kg (6616), _
Operating temperature range ,.' :1 , j '
- 25 °C -.'+60°C '
.,:::Noise emission {typical)
26 d8(A) .: , ..
30
.,
Internal power consumption a.Friight
-Topology -- _
Transformerless
Cooling concept ., _.
Conyechon
For.
Features
Secure Power Supply
"
Display. 12 x 16.ch'ra cteis) - ..
` :
•.
Iriterfocesifthernet/_WLAN .` .
:';:
/ •
Sensor module / Extemdl WIAN anteri.np
v ...
_ 0 / q
Warranty: l0/,15%,20years'
certikates and approvals
UL 174T U1;1998; UL,1699B; IEEE 1547, ECC Part, l'5 (Class A &:B), CAN%CSA y22.2 107. t--]
Standard features , O Optional features — Not available
r- Data at nominal conditions
., N.OTE: US inverters:ship with gray lids. ' Preliminary data, UL pending ..-
TYpe designahon , ';., . _
SB6;41`SP-USAO .r; .
_ . , r '.,c SB7 0-1 SP-US40 ,. �.
SB7 7 -1,5P -US -4,
SAME NAME, NEW GAME
The Sunny Boy 3.0 -US through 7.7 -US are once again raising the
bar by offering improved performance, enhanced features, and most
importantly, an economical approach to residential solar. Your business
model is a value chain. The new Sunny Boy -US series can help you stay
competitive in an increasingly price sensitive residential market by driving
down costs across all of your business operations.
.................................. .... ...............................
Speed the completion of customer proposals and maximize the efficiency of your design
team with the Sunny Boy -US series, which provides a new level of flexibility in system
design by offering:
» Hundreds of stringing configurations and multiple independent MPPTs
» SMA's proprietary OptiTracTm Global Peak shade mitigation technology
» Diverse application options including on- and off -grid compatibility
...................... :..................................................................................................
:
SMA wants to enable your sales team by arming them with an abundance of feature/
benefit support. Show your customers the -value of the Sunny Boy -US series by utilizing:
» Secure Power Supply, now with 2,000 W of opportunity power in the event of a grid
outage, as on increased value -add or upsell opportunity
» SMRs 35 year history and status as the #1 global inverter manufacturer instills homeowners
`.N with peace of mind and the long-term security they demand from a PV investment
» An economical solution for shade mitigation and the challenges of complex roofs
r
......................................................................................................................
Ensure that your back office business operations run smoothly and succinctly while
mitigating potential errors. The Sunny Boy -US series can help achieve cost savings in
these areas by providing:
» An integrated DC disconnect that simplifies equipment stocking and allows for a single
inverter part number
» All communications integrated into the inverter, eliminating the need to order
additional equipment
........................................................ .................. .................................. .........
STREAMLINED INSTALLATION AND COMMISSIONING
Expedite your operations in the field by taking advantage of the new Sunny Boy's
installer -friendly feature set including:
» Direct access via smartphone and utilization of SMA's Installation Assistant, which
minimizes time/labor spent in the field and speeds the path to commissioning
» Improved communication—no need to install additional equipment
» Integrated DC disconnect that simplifies onsite logistics and eliminates the need to
install a separate disconnect unit, speeding overall installation time
.......................... .........................................................
...................:..............
SUPERIOR
.............................................................................
SMA understands the factors that contribute to lifetime PV ownership cost, that's why
the Sunny Boy -US series was designed for maximum reliability and backstopped by an
unmatched service offering. Benefit from:
» The new Sunny Boy's two-part enclosure concept that separates the connection unit
from the power unit, which allows for simple, -expedited servicing
The #1 service team in the PV industry, as recognized by IMS research, with
experience servicing an installed base of more than 40 GW
......................................................................................................................
MAXPOWER (1500 V)
C56U-325133013351340M
Canadian Solar's new 1500 V module is a product
for high voltage systems, which can increase the
string length of solar systems by up to 50%, saving
BOS costs.
KEY FEATURES
1500V Designed for high voltage systems of up
to 1500 Vpc, saving on BoS costs
25 linear power output warranty„
years
10 product warranty on materials'
years and workmanship
MANAGEMENT SYSTEM CERTIFICATES*
a 8 Cell efficiency of up to 20.0 % ISO 9001:2008 / Quality management system
ISO 14001:2004 / Standards for environmental management system
OHSAS 18001:2007 / International standards for occupational health & safety
Outstanding low irradiance
performance: 96.5 % PRODUCT CERTIFICATES*
IEC 61215 / IEC 61730: VDE / CE '
UL 1703 / IEC 61215 performance: CEC listed (US)
No.1 High PTC rating of up to 91.7 oda UL 1703: CSA /IEC 61701 ED2: VDE / IEC 62716: VDE / Take -e -way
PTC
IP67 junction box for long- • As there are different certification requirements in different markets, please contact
I term weather endurance your local Canadian Solar sales representative for the specific certificates applicable to
the products In the region in which the products are to be used.
*** Heavy snow load up to 5400 Pa, CANADIAN SOLAR INC. is committed to providing high quality
® wind load up to 2400 Pa solar products, solar system solutions and services to customers
around the world. As a leading PV project developer and
manufacturer of solar modules with over 15 GW deployed around
the world since 2001, Canadian Solar Inc. (NASDAQ: CSIQ) is one of
the most bankable solar companies worldwide.
ENGINEERING DRAWING (mm)
Rear View
CS6U-335M / I-V CURVES
A
Frame Cross Section A -A 10
9
8
4!3
7
6
5
4
3
2
Mounting Hole 1
0
I J
/5 %_
1 7 /
u
ELECTRICAL DATA I STC*
CS6U 325M 330M 335M 340M
Nominal Max. Power (Pmax)
325 W
330 W
335 W
340 W
Opt. Operating Voltage (Vmp)
37.4 V
37.5 V
37.8 V
37.9 V
Opt. Operating Current (Imp)
8.69 A
8.80 A
8.87 A
8.97 A
Open Circuit Voltage (Voc)
45.8 V
45.9 V
46.1 V
46.2 V
Short Circuit Current (Isc)
9.21 A
9.31 A
9.41 A
9.48 A
Module Efficiency
16.72% 16.97% 17.23% 17.49%
Operating Temperature
-400C - +850C
Max. System Voltage
1500 V (IEC) or 1500 V (UL)
Module Fire Performance
TYPE 1 (UL 1703) or
CLASS C (IEC 61730)
Max. Series Fuse Rating
15A
Application Classification
Class A
Power Tolerance
0-5W
*Under Standard Test Conditions (STC) of irradiance of 1000 W/mz, spectrum AM
1.5 and cell temperature of 25°C.
ELECTRICAL DATA I NOCT*
CS6U 325M 330M 335M 340M
Nominal Max. Power (Pmax)
235 W
238 W
242 W
245 W
Opt. Operating Voltage (Vmp)
34.1 V
34.2 V
34.5 V
34.6 V
Opt. Operating Current (Imp)
6.88 A
6.96 A
7.01 A
7.10 A
Open Circuit Voltage (Voc)
42.0 V
42.1 V
42.3 V
42.4 V
Short Circuit Current (Isc)
7.46 A
7.54 A
7.62 A
7.67 A
* Under Nominal Operating Cell Temperature
(NOCT), irradiance
of 800 W/mz,
spectrum AM 1.5, ambient temperature 20°C, wind speed 1 m/s.
PERFORMANCE AT LOW IRRADIANCE
Outstanding performance at low irradiance, average
relative efficiency of 96.5 % from an irradiance of 1000
W/m2 to 200 W/m2 (AM 1.5, 250C).
The specification and key features described In this datasheet may deviate slightly
and are not guaranteed. Due to on-going innovation, research and product
enhancement, Canadian Solar Inc. reserves the right to make any adjustment
to the information described herein at any time without notice. Please always
obtain the most recent version of the datasheet which shall be duly Incorporated
Into the binding contract made by the parties governing all transactions related
to the purchase and sale of the products described herein.
Caution: For professional use only. The installation and handling of PV modules
requires professional skills and should only be performed by qualified professionals.
Please read the safety and Installation instructions before using the modules.
A
10
9
8
7
6
5
4
3
2
1
v 0
5 10 15 20 25 30 35 40 45 50
5 10 15 20 25 30 35 40 45 50
V
1000 w/m' 5-C 2
800 w/m, 25°C 111
600 W/m' 45•C ■
400 W/m' 65-C N
MECHANICAL DATA
Specification Data
Cell Type
Mono -crystalline, 6 inch
Cell Arrangement
72 (6 x 12)
Dimensions
1960 X 992 X 40 mm (77.2 X 39.1 X 1.57 in)
Weight
22.4 kg (49.4 lbs)
Front Cover
3.2 mm tempered glass
Frame Material
Anodized aluminium alloy
J -Box
IP67, 3 diodes
Cable
PV150ODC-F1 4 mm2 (IEC) & 12 AWG
2000 V (UL), 1160 mm (45.7 in)
Connector
T4 series or PV2 series
Per Pallet
26 pieces, 635 kg (1400 lbs)
Per container (40' HQ)
624 pieces
TEMPERATURE CHARACTERISTICS
Specification
Data
Temperature Coefficient (Pmax)
-0.41 % / °C
Temperature Coefficient (Voc)
-0.31 % / °C
Temperature Coefficient (Isc)
0.053 % / °C
Nominal Operating Cell Temperature
45±2 °C
PARTNER SECTION
rL
structural
ENGINEERS
January 12, 2017 '
UniRac
1411 Broadway Boulevard NE
Albuquerque, New Mexico 87102-1545
TEL: (505) 242-6411
FAX: (505) 242-6412
Attn.: Engineering Department,
Re: Engineering Certification for UniRac's SolarMount Code -Compliant Installation Manual 227.3
PZSE, Inc. -Structural Engineers has reviewed UniRac's "SolarMount Code -Compliant Installation Manual
227.3" published January 2014 and specifically "Part I. Procedure to Determine the Design Wind Load", and
"Part II: Procedure to Select Rail Span•and Rail Type".
The procedures are used to determine the calculation of the design wind force, load combinations; applied
loading and rail selection. All information, data and analysis contained within the Installation Manual are based
on, and comply with the following:'
1. Minimum Design Loads for Buildings and other Structures; ASCE/SEI 7-05 and ASCE/SEI 7-10
2. 2012 & 2015 International Building Code, by International Code Council, Inc.
3. 2013 & 2016 California Building Code, by.California Building Standards Commission
4.' 2010 & 2015 Aluminum Design Manual, by The Aluminum Association
This letter certifies that the structural cal cul ations -contained within UniRac's "SolarMount Code -Compliant
Installation Manual 227.3 are in compliance with the above Codes.
If you have any questions on the above, do not hesitate to call.
Prepared by:
PZSE, Inc. --Structural Engineers
Roseville, CA
81'50 Sierro College 6'oulevard Suite: 150 Roseville =_CA 95661;
T'916.9761 3960 ' Q 16 961,:39.6"5; DRi www pzse.coM
}�s�ep.�� l <t►�t�±�. 1 Etfi�vtaYaerii''
� V
A HIM GROUP COMPANY
SolarMount Technical Datasheet
Pub 110818 -ltd V1.0 August 2011
SolarMount Module Connection Hardware.................................................................. 1
Bottom Up Module Clip... .......................1
Mid Clamp
.................................................:....2
EndClamp ........... ..........................:...................... . ....:..........2
SolarMount Beam Connection � Hardware ......................................................................3
L -Foot 3
_..............:...................................................................
SolarMount Beams:...:......:...........................................::..............:...............................:..4
SolarMount Module Connection Hardware
SolarMount Bottom Up Module Clip �•
Part No. 302000C,
• . W h Bottom Up Clip material: One of the following extruded aluminum
�` allo s 6005-T5, 6105-T5, 6061-T6
Bottom Nut ^�F (hidden seep Y
Up Chp°'f t note'j Ultimate tensile: 38ksi, Yield: 35 ksi ;
Finish: Clear Anodized
Bottom Up Clip weight: —0.031 Ibs (14g)
'BoAllowable and design loads are valid when components are .
Beam M 2 /t '' assembled with SolarMount series beams according to authorized
" f. UNIRAC documents -
,F z ...........r Assemble with one'/" -20 ASTM F593 bolt, one Y"-20 ASTM F594
serrated flange nut, and one '/" flat washer
6 Use anti -seize and tighten to 10 ft -lbs of torque
Resistance factors and safety factors are determined according to
part 1 section 9 of the 2005 Aluminum Design Manual and .-' third-
� party test results from an IAS accredited laboratory*
• Module edge must, be fully supported by the beam
• * " NOTE ON WASHER: Install washer on bolt head side of assembly.
DO NOT install washer under serrated flange nut
L,?t 1,24
t.co
Dimensions specified in inches unless noted
Applied Load
Direction
Average
Ultimate
lbs (N)
' Allowable
Load
lbs (N)
Safety
Factor,
FS
Design
Load
lbs (N)
Resistance
Factor,
m
Tension, Y.+
1566 (6967)
686 (3052)
2.28
1038 (4615)
0.662
Transverse, X±
1128 (5019) •
1 329 (1463) 1
3.43
497(2213),
0.441
Sliding, Zt
i 66 (292)
1 27 (119) 1
2.44
41(181)1
0.619
o .rel I 1 71 dP
A HIL71 GROUP COMPANY
SolarMount Mid Clamp
Part No. 302101 C, 302.101 D, 302103C, 302104D,
30215D, 302106D
r7 C
rra;; A'Bolt.alloys:
Mid clamp material: One of the followingextruded aluminum
Allowable
Load
lbs (N)
Safety
Factor,
FS
Design
Load
lbs (N)
y 6005-T5, 6105-T5, 6061-T6
Clam P
la a Nu.;r r
529 (2352)
• . Ultimate tensile: 38ksi, Yield: 35 ksi
1348 (5994)
0.667
,Transverse, Z±
520 (2313)
• Finish: Clear or Dark Anodized
2.27
346 (1539)
0.665
f
Mid clamp weight: 0.050'Ibs (23g)
490 (2179)
2.44
1 741 (3295)
�a
Allowable and design loads are valid when components are
assembled according to authorized UNIRAC documents
• t ..Q
Ltr~�w�r+MoouLEs t
Y-....
• _ ►'X
Dimensions specified in inches unless noted
SolarMount End Clamp
PartNo.302001C,302002C,302002D,302003C,
302003D,302004C,302004D,302005C,302005D,
302006C,302006D,302007D,302008C,302008D,
302009C,302009D,302010C,302011C,302012C
• • _ _� �.-''���'h%�olW tom'
Values represent the allowable and design load capacity of a single
mid clamp assembly when used with a SolarMount series beam to
retain a module in the direction indicated
• Assemble mid clamp with one Unirac 1/4"-20 T -bolt and one %"-20
ASTM F594 serrated flange nut
• Use anti -seize and tighten to 10 ft -lbs of torque
Resistance factors and safety, factors are determined according to
part 1 section 9 of the 2005 Aluminum Design Manual and third -
party test results from an IAS accredited laboratory
Applied Load
Direction
Average
Ultimate
lbs (N)
Allowable
Load
lbs (N)
Safety
Factor,
FS
Design
Load
lbs (N)
Resistance
Factor,
m
Tension, Y+
2020(P987) .891(3963)
529 (2352)
2.27
1348 (5994)
0.667
,Transverse, Z±
520 (2313)
229 (1017)
2.27
346 (1539)
0.665
Sliding, X±'
1194 (5312)
490 (2179)
2.44
1 741 (3295)
0.620
�X
F a+e�snux
VAASE�Ms.+ #•i.
• xoout� ' f
THL4Ai+E5S � .
Dimensions
f
3
End clamp material: One of the following extruded aluminum
alloys: 60057T5, 61057T5, 6061-T6
.Ultimate tensile: 38ksi, Yield: 35 ksi
Finish: Clear or Dark Anodized
End clamp weight: varies based on height: —0.058 lbs (26g)
Allowable and design loads are valid when components are
assembled according to authorized UNIRAC documents
Values represent the allowable and design load capacity of a single
end clamp assembly when used with a SolarMount series beam to
retain a module in the direction indicated
Assemble with one Unirac'/"-20 T -bolt and one W-20 ASTM F594
serrated flange nut
Use anti -seize and tighten to 10 ft -lbs of torque
Resistance factors and safety factors are determined according to
part 1 section 9 of the 2005 Aluminum Design Manual and third-
: party test results from an IAS accredited laboratory
Modules must be installed at least 1.5 in from either end of a beam
Applied Load
Direction
Average
Ultimate
lbs (N)
Allowable
Load
lbs (N)
Safety
Factor,
FS
Design
Loads
lbs (N)
Resistance
Factor,
m
Tension, Y+
1321 (5876)
529 (2352)
2.50
800 (3557)
0.605
Transverse, Z±
63 (279)'
14 (61)
4.58
21 (92)
0.330
Sliding, X± '
t 142 (630)
52 (231)
2.72 t
79 (349)
0.555
6:101 WAI• 1
A HILTI GROUP COMPANY
SolarMount Beam Connection Hardware,
SoIarftbnt L -Foot. -
Part No. 304000C, 304000D i
• ......L -Foot material: One of the following extruded aluminum alloys: 6005
R T5, 6105 -T5,6061 -T6 -
h Ultimate tensile: 38ksi, Yield: 35 ksi `
` Finish: Clear or Dark Anodized
L -Foot weight: varies based on height:, -0.215 lbs (98g)
Allowable and design loads are valid when components are
assembled with SolarMount series beams according to authorized
Bea
Bolt c: • UNIRAC documents '
L -Foot For the beam to L -Foot connection:
• Assemble with one ASTM F593 W-16 hex head screw and one
eiiated ;{!• ASTM F594 Wserrated flange nut
Flange Nu r , '� Use anti -seize and tighten to 30 ft -lbs of torque
Resistance factors and safety factors are determined according to part
1 section 9 of the 2005 Aluminum Design Manual and third -party test
Y = results from an IAS accredited laboratory
NOTE: Loads are given for the L -Foot to beam connection only; be
X sure to check load limits for standoff, lag screw, or other
attachment method
X SLOT,
Dimensions specified in inches unless noted
Applied Load
Direction
'
, ' Average
Ultimate
lbs (N).
Allowable Load
lbs (N)
Safety
Factor,
FS
'. Design
Load
lbs (N)
Resistance
Factor,
m
Sliding, Z±
1766 (7856)
755 (3356)
2.34
1141 (5077)
0.646
"Tension; Y+
1859 (8269)
707 (3144)
2.63
1069(4755)..
0.575
Compression, Y,-
3258 (14492),
1325 (5893)
2.46
2004 (8913)
0.615
Traverse ;X+
.486(2162)
-' 213 (949)
2.28
323(1436)1
0.664
• . imv rei
A HILTI GROUP COMPANY
•SolarMount Beams
Part No. 310132C, 310132C-B,,310168C, 310168C -B; 310168D
310208C; 310208C -B, 310240C, 310240C -B, 310240D;
410144M,.4101.68M, 410204M, 410240M
Properties
r.
" SolarMount
7
SolarMount HD
Beam Height - YE� "
''in
- 2.5 . -
3.0
Approximate Weight (per linear ft),
plf
0.811
-'1.271 '
»-
4! `
0.676
Properties
, . Units
" SolarMount
7
SolarMount HD
Beam Height - YE� "
''in
- 2.5 . -
3.0
Approximate Weight (per linear ft),
plf
0.811
-'1.271 '
Total Cross Sectional Area - _
in'
0.676
1.059
Section Modulus (X -Axis) .
in3-
0.353
.• 0.898 '
Section.Modulus (Y -Axis)
in
0.113 -
0.221
Moment of Inertia (X -Axis) . -
in4
0.464
.1.450
Moment of Inertia (Y -Axis) . -
in
0.044
0.267,
Radius of Gyration (X -Axis)
in,
0.289
1.170
Radius of Gyration (Y --Anis)
in
0.254 . _,
0.502
SLOT FOR T -BOLT OR 1.728-
SLOT FOR T -BOLT OR
r 14" HDC HEAD SCREW Y4 --,-HED( HEAD SCREW
2X SLOT FOR SLOT FOR
BOTTOM CLIP• 2.500 BOTTOM CLIP r'
�. 3.000
- 1.31617
T SLOT FOR _ Y
3/8" HEX BOLT', ` SLOT FOR, 1.385 _
e HBOLTHEX a
387 . -
.750
1.207
Y .. :.. `' Y . 1.875 _
SolarMount Beam SolarMount HD Beam_ `
Dimensions specified in inches unless noted't ° '
Detached non -habitable structure: Cal Fire`regulations
state that setback requirements do not apply to --
detached non -habitable structures .
Junction boX. '
PV. #10 to inverter
D �� v
Inverter
Sub panel ;
-
` � . , of • -
" Metal roof. stanchion '
g 2' max cantilever max span
OMSP 263' south on
power, pole e`
1800 XC
1. THIS SYSTEM IS GRID-INTERTIED VIA (1) UL -LISTED POWER CONDITIONING ROOF Plan & Truss SectionRev. Date Description
INVERTERS , SMA SUNNY BOY 9000TL-US (240 VAC) Drawn BY:• David W
W 2. SYSTEM IS GROUNDED VIA BONDED COPPER WIRE 8& UNIRAC BONDING CLIPS Client : Elliott Dutro ,
3. THIS SYSTEM HAS NO UPS, NO BATTERIES - 2880 Chico River Road, Chico CA 95928 Date: 09/13/2017
4. THIS IS A ROOF -MOUNTED SYSTEM, ADDING 2.81 LB/sgFT. ROOF IS (1) LAYER
OMETAL SHEET ROOFING (ROOF SLOPE IS 4:12)
5. ROOF JOISTS ARE 2X4" ENGINEERED TRUSSES AT 24" O.C. SPACING `Scale NTS
Z6. LAG SCREWS ARE 5/16" x 4" AT 72" O.C. MAX, W/3" INTO FRAMING.
7. LABELING DETAIL ON ATTACHED SHEET -T - 17 74L -W nr. Phntnvnitalr rQv0prn 111; ran;4A;kn rsnlar i'CL;I 1-1411M1 ;
U
LL
}
wOa "
OQSU
� " w
w�~
moa
rc a 0
�ws<i
�N
ow wa7 r
ZaQNO
U K LL w ¢
MM
�a4t
w w Q z
wml-n
X30
LL
�.0
aozo� .
c73o�j�¢i1
•OVwS
N
a
Z
a
a`
v
U
0
O
O
L
a
U
D
N N
m i -I
o °C u
_ u mm
O
p u
N V
G
E
Single Line
Diagram
SMA
_
{
SB5.0-1SP-US-40 (240V)
CANADIAN SOLAR
'INVERTER DC • INVERTER
RAPID
DISCONNECT # -
CS6U-340M
SH UTDOWN
"
SYSTEM
101
T.
1
1
10
•
i
1- --
,—
�—— — — — — — — —
------------�
_ —
- -
SMA-
SB3.8-1SP—US-40 (240V)
1
INVERTER DC INVERTER
CANADIAN SOLAR
-
RAPID
DISCONNECT #
1
71'75,
-
CS6U-340M
`
SHUTDOWN
SYSTEM
I
I
'8
1 i
i
- -
y 20A2P
50A2P -
8
•
/
Ex. Loads
�,}
----- -- —
GFDI
----�
— -{]
L+-----+
±---------
I,
O L ---moi]
200A
------
---J
O
Main Service Panel
O 125A Load Center
.1 20/240V 1 �, 3W
•
-
120240V, 1�, 3W
...
.
-
RAPID
.
-
-
SHUTDOWN
•
SYSTEM
•
-
BUTTON
NOTE: SEE NEXT SHEET FOR WIRE/ITEM CALLOLITS'
U
LL
}
wOa "
OQSU
� " w
w�~
moa
rc a 0
�ws<i
�N
ow wa7 r
ZaQNO
U K LL w ¢
MM
�a4t
w w Q z
wml-n
X30
LL
�.0
aozo� .
c73o�j�¢i1
•OVwS
N
a
Z
a
a`
v
U
0
O
O
L
a
U
D
N N
m i -I
o °C u
_ u mm
O
p u
N V
G
E
Single Line
Diagram
DC SOURCE INFORMATION
Circ. Name
MODULES CONNECTED TO INVERTER 1
20
MODULES
MODULES CONNECTED TO INVERTER 2
16
MODULES
5000
W
Nominal Output Voltage
240
VAC
Number of Phases
1
PH
Nominal Output Current
20.83
A
AC OCP Rating
30
A
Max. Array Input Voltage
600
VDC
MPPT Min at Full Power
100
VDC
MPPT Max at Full Power
Total number of PV Modules
36
MODULES
Number of modules in largest string
10
MODULES
TOTAL CEC RATING OF SYSTEM
10.86
kW
MAXIMUM NUMBER OF MODULES PER STRING
VMAX = VOC + ((T_low-TREF) x aVOC)
% / °C
VOC
46.2
V
T low (ASHRAE Low Design Temp.)
-3
°C
TREF (Cell Temperature at STC)
25
°C
aVOC (Temp. Coeffecient of Voc)
-0.0031
%/°C
VMAX Per Module
50.21
V
Number of modules in largest string
10
MODULES
VSTRING MAX = NMAX x VMAX
401.7
Voltage of Maximum String Size
14.81
502.1 V
INVERTER 1 SPECIFICATIONS
Circ. Name
Manufacturer
ASHRAE DATA
SMA
Model #
SB 5.0-1SP-US-40 (240V)
Nominal AC Power
5000
W
Nominal Output Voltage
240
VAC
Number of Phases
1
PH
Nominal Output Current
20.83
A
AC OCP Rating
30
A
Max. Array Input Voltage
600
VDC
MPPT Min at Full Power
100
VDC
MPPT Max at Full Power
550
VDC
Inverter Efficiency
97
%
Number of Modules Connected to Inverter
120
MODULES
CEC Rating of Modules Connected to Inverter
16.05
kW
INVERTER 2 SPECIFICATIONS
Circ. Name
Manufacturer
ASHRAE DATA
I SMA
Model #
SB 3.8-1SP-US-40 (240V)
Nominal AC Power
3800
W
Nominal Output Voltage
240
VAC
Number of Phases
1
PH
Nominal Output Current
16
A
AC OCP Rating
20
A
Max. Array Input Voltage
600
VDC
MPPT Min at Full Power
100
VDC
MPPT Max at Full Power
550
VDC
Inverter Efficiency
96.5
%
Number of Modules Connected to Inverter
16
MODULES
CEC Rating of Modules Connected to Inverter
4.81
kW
CONDUCTOR AND CONDUIT SCHEDULE (COPPER)
DESIGN TEMPERATURES
Circ. Name
Circ.
Conductor
ASHRAE DATA
Load(A)
Lowest Expected Temperature
Tamb
-3
°C
Average High Temperature
# of Runs
per Phase
41
°C
PV MODULE SPECIFICATIONS
Manufacturer
Amperage(
A)
CanadianSolar
Model #
Voltage Drop
(%)
CS6U-340M
PMAX (Nominal Output)
340
W
VMP (Voltage at Pmax)
37.9
V
IMP ( Current at Pmax)
8.97
A
VOC (Open Circuit Voltage)
46.2
V
ISC (Short Circuit Current)
9.48
A
NOTC
25
°C
Temperature Coefficient of Pmax
-0.41
% / °C
Temperature Coefficient of Voc
-0.0031
% / °C
Temperature Coefficient of Isc
0.053
%/ °C
MAXIMUM SYSTEM VOLTAGE
1000
VOLTS
Module PTC Rating
311.8
W
VDROP SCHEDU LE
IDN
Circ. Name
Circ.
Conductor
Voltage(V)
Load(A)
Ampacity for
OCP (A) (Load
x 1.25)
Tamb
Raceway
Conductor Required
Ampacity (A)
Conductor Size &Type
# of Runs
per Phase
Conductor
Ampacity
Copper
E.G.0
CONDUIT
Voltage(V)
Amperage(
A)
LENGTH
1 WAY
Voltage Drop
(%)
1
PV -1 String
PV +/-
502.1
11.85
14.81
0.82
1.0
14.81
#10 PV Wire
1
35
#10
N/A
379.0
8.97
50
approx
0.29
2
PV -1
PV -1 +/-
502.1
23.70
29.63
0.82
1.0
29.63
#30 THWN-2
1
35
#10
3/4" EMT
379.0
8.97
45
approx
0.26
3
1 PV -2 String
PV +/-
401.7
11.85
14.81
0.82
1.0
14.81
#30 PV Wire
1 1
35
#30
N/A
303.2
8.97
50
approx
0.33
4
PV -2
PV -2+/-
401.7
23.70
29.63
0.82
1.0
29.63
#10 THWN-2
1
35
#10
3/4"EMT
303.2
8.97
45
approx
0.30
5
INV 1
L1,L2,N
240.0
20.83
26.04
0.82
1.0
26.04
#10 THWN-2
1
35
#10
3/4" EMT
240.0
20.83
10
approx
0.20
6
INV 2
L1,L2,N
240.0
16.00
20.00
0.82
1.0
20.00
#10 THWN-2
1
35
#10
3/4" EMT
- 240.0
16.00
10
approx
0.15
7
SUBOUT
L1,L2,N
240.0
36.67
45.83
0.82
1.0
45.83
#3 THWN-2
1
100
#6
1-1/2" EMT
240.0
36.67
270
1 approx
1.83
NOTES: NOTES: Feeder from 125A Solar Panelboard to be fed with (2) #3 AWG Copper (1) #6 AWG Copper Neutral and (1) #6 AWG Copper Ground per CEC 2013 705.95 (B).
U
N
�row
w
w N O
02WW
~
LL Q
ULH
w O
I -F
QRza
�WzoFNF
W
wKa
ipQ'
x8wowz
LL
N
U=LL .w
-W
mJzf
�ZSo
<- 00
lu-Z
a�yao
0
z6zo
�o�rc
w� �y
o wg
F
a)
N
>)
N
U
M
O
O
O
t
a
Y
c N
m
m -4.4
O N
5 a
p r V
o
L
u
§
P
Bill Of
Materials
October 20, 2017
Summit Structural Design
383 Rio Lindo Avenue, Suite 200, Chico, California 95926
p. (530) 592-4407 www.summitchico.com
RE: Existing Olympia Steel Building (Approximately 45'x 50') .
2880 Chico River Road, Chico, CA
To Whom It May Concern:
On October 20th, 2017, 1 observed (1) existing Olympia Steel Building (shown on attached
Google Earth image) at the address above. The building was constructed in approximately
2006 and appeared to be in good condition at the time of my visit, without signs of
deterioration, leaning, or deflection. It is my opinion that the building is both structurally
sound and that the primary gravity framing system of the existing metal building is capable of
supporting flush mounted roof solar panels.
This letter represents my professional opinion only and is not a guarantee or warrantee of
the existing structure Liability for the structure and solar. installation, and any potential
damage as a result of structural failure of all or part of the building or solar installation, shall
remain the responsibility of the building owner and contractor. Please don't hesitate to
contact me with any questions.
Sincerely,
Ryland Burdette, P.E.
C
r
EXP.
CIVIL
\OF CALIF
SMA -
SB5.0-1SP-US-40 (240V)
CANADIAN SOLAR 'INVERTER DC *INVERTER
RAPID DISCONNECT #
CS6U-340M SHUTDOWN
SYSTEM
10 1 •
Eiffli
T 1
10� 11
�—----------------- --- -
SMA 1
SB3.8-1SP-US-40 (240V) I M
INVERTER DC INVERTER
CANADIAN SOLAR RAPID DISCONNECT #
CS6U-340M s"SYSTEM
' I 175A
r-- — -- --T
Q
7
v
T
N
30A2P ,
V
20A/2P50A/2P
•
•
/
Ex. Loads
1 1
t
f r ��—
I 74—
— — — GFDI — —
— — -{ST.�
L---------------------------1
O
L - — — 200A
"
O
Main Service Panel
>o
Y
O
125A Load Center "120l240V 10, 3W
N
-
120240V, 1¢, 3W
.
m
2 O m
RAPID
p t V
0 p C
r U
SHUTDOWN
SYSTEM
-
BUTTON
• rti
NOTE: SEE NEXT SHEET FOR WIRE/ITEM CALLOLITS'
A
U I
LL
V >Z
asW QLL
w
wO
wum z
a
2"-v -0
00SU
~LLw¢
w
oZz�
zo OF
o,aow
ww3af
20w0Zw
r, o 5.
¢¢aN
W07��.
mJzii
szgOR
N a U
r>ZO
21
005
a2Fa
-8Edz
2
OUNO
a
Q
E
v
T
N
U
M
..
0
0
O
L
d
"
u
>o
Y
N
owe
m
2 O m
rN•i
p t V
0 p C
r U
i
4
Single Line
Diagram