Loading...
HomeMy WebLinkAboutB17-2603 047-770-005BUTTE COUNTY V DEPARTMENT OF DEVELOPMENT SERVICES AREA INSPECTION CARD MUST BE ON JOB SITE 4 24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspections is 3pm) . Development Services cannot guarantee inspections on the date requested ' Office: 530.538.7601 Fax:530.538.7785 www.ButteCounty.net/dds Permit No: B 17-2603" Issued: 10/31/2017 APN: 047-770-005 Address: 3942 SPYGLASS RD, CHICO' Owner: FLAHERTY, PATRICK F & LORI HEAD .. Permit Type:. SOLAR ROOF -RES , Flood Zone: None SRA Area: No , SETBACKS for Zoneno. AG. SRA. -PW* s Front: Centerline of Road: Rear: SRA = Street: AG: Interior Description: 10.72kW roof rant w/32 LG335N1C-A5 Total Setback from Centerline of Road: „ .:" ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING . Inspection Te ' IVR INSP DATE Setbacks - 131 Foundations / Footings 111 Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Sign d Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 Blockin nde inin 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed - Shearwall/B. W.P.-Interior 134 Shearwall/B.W.P.-Exterior' 135, 3 Roof Nail/Drag Trusses 129 Manometer Test 605 Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing153 Skirting/Steps/Landings Rough Plumbing 406 •Rou h Mechanical P 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Plumbing Final 813 Fire Sprinkler Test or Final 702 Swimming Pools ' Setbacks 131 Pool Plumbing Test 504 r Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 503 Pre -Plaster 507 Manufactured Homes . Setbacks. -131 Blockin nde inin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613. Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Skirting/Steps/Landings 610 Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: - Serial Numbers: Length x Width: Insignia: s.7 _,�. :w;�. } ;' :;' Finals { , -�, ;,, ,, - Permit Final 802 . Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test or Final 702 Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final "PROJECT FINAL _ --rrujcct r u=at is a w,eruucace o= occupancy for txes=aenna= vmy) „ PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF -ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR , "- RENEWAL 30 DAYS PRIOR TO EXPIRATION . a Butte County Department of Development Services PERMIT CENTER 7 County Center Drive, Oroville, CA 95965 raw�xrrnuee Main Phone (530) 538-7601 Fax (530) 538-7785 w-ww.buttecotinty.net/dds FORM .NO DBI -01 Declaration of Installation for Smoke Alarms and Carbon Monoxide Alarms The newly adopted 2013 California Residential Code requires the installation of Carbon Monoxide Detectors in dwelling units and in sleeping units within which fuel -burning appliances are installed and in dwelling units that have attached garages. The policy for Carbon Monoxide Alarms in Butte County states: "Any permit obtained in which the value of work exceeds $1000 associated with a Residential Group R Dwelling Unit or Sleeping Unit shall conform to the following 2013 California Residential.Code requirements for Smoke and Carbon Monoxide Alarms (Section R314 & R315):" 2013 California Residential Code requirements for Carbon Monoxide Alarms: R315.1 New construction: An approved carbon monoxide alarm shall be installed in dwelling units and in sleeping units within which fuel -burning appliances are installed and in dwelling units that have attached garages. R315.1.2 Power supply: For new construction required carbon monoxide alarms shall receive their primary power from the building wiring where such wiring is served from a commercial source and shall be equipped with a battery back-up. Alarm wiring shall be directly connected to the permanent building wiring without a disconnecting switch other than as required for over - current protection. Exceptions: 1. In dwelling units where there is no commercial power supply the carbon monoxide alarm may be solely. battery operated. 2. In existing dwelling units a carbon monoxide alarm is permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. R315.1.3 Interconnection. Where more than one carbon monoxide alarm is required to be installed within the dwelling unit or within a sleeping unit the alarm shall be interconnected in a manner that activation of one alarm shall activate all of the alarms in the individual unit. Exception: 1. Interconnection is not required in existing dwelling units where repairs do not result in the removal of wall and ceiling finishes, there is no access by means of attic basement or crawl space" and no Previous method for interconnection existed. R315.2 Where required in existing dwellings: Where a permit is required for alterations, repairs or additions exceeding one thousand dollars ($1,000), existing dwellings or sleeping units that have attached garages or fuel -burning appliances shall be provided with a carbon monoxide alarm in accordance with Section R315.1. Carbon monoxide alarms shall only be required in the specific dwelling unit or sleeping unit for which the permit was obtained. R315.2.6 Alarm requirements: No person shall install, market, distribute, offer for sale or sell any carbon monoxide device in the State of California unless the device and instructions have been approved and listed by the State Fire Marshal. Pagel of 2 Revised 7.20.2015 Carbon `monoxide alarms required by Sections R315.1 and R315.2 shall be installed in the following locations: 1. Outside of each separate dwelling unit sleeping area in the immediate vicinity of the bedroom(s). 2. On every level of a dwelling unit including basements. R315.1.5 Multiple -purpose alarms: Carbon monoxide alarms combined with smoke alarms shall comply with Section R315, all applicable standards, and requirements for listing and approval by the Office of the State Fire Marshal, for smoke alarms. Butte County's Interpretation of 2013 CRC, Sections 314 & 315 for Smoke Alarms & Carbon Monoxide Alarms: Where alterations, repairs or additions exceeding $1,000 in valuation, existing dwellings shall be retrofitted with smoke alarms and those that have attached garages or fuel -burning appliances shall have carbon monoxide alarms installed. Existing smoke alarms can be replaced with dual function alarms for Smoke and Carbon Monoxide and in most cases will comply with the aforementioned code requirements for Carbon Monoxide Alarms. DECLARATION OF INSTALLATION UNDER THE PENALTY OF PERJURY As Owner/Contractor, I/we affirm and declare under the penalty of perjury, under the laws of the State of California, by our signatures below as Owner/Contractor, that I/we will comply prior to final inspection with Items, A & B as specified herein: A. Both Owner/Contractor have read and clearly understand the aforementioned 2010 California Residential Code (CRC) Carbon Monoxide Alarm requirements. B. Both Owner/Contractor are responsible for installing Carbon Monoxide Alarms prior to final inspection as per the aforementioned building code and maintaining such installation. Smoke Alarms. will also be installed prior to final inspection as per the 2010 CRC. Smoke and .Carbon Monoxide alarms are now installed in the following locations: Owner's name (print): Patrick Flaherty Owner's signature, pY'GG�GG�l�j Date: 10/23/17 Contractor's name (print): United Sun Energy CSLB License: 977269 Contractor's signature: Date: 10/23/17 Project Address: 3942 Spyglass Rd., Chico CA 95973 permit #: Page 2 of 2 Revised 7.20.2015