HomeMy WebLinkAboutB17-2710 040-260-056m
CALCULATION PACKAGE
BUILDER: SUPERIOR CONSTRUCTION
CUSTOMER: TOM HUSING
JOB NUMBER: 16-B-11185
TABLE OF CONTENTS
Original Design Completed thru Change Order # 01
Revision History
Rev # Update Reason for Revision Pages Revised
Reactions.
Page
LOC
1
Design Criteria
2
Building Sketch
3
Design Summary
4-12
Special Detail
13 -14 -
Design Reactions
15-16
Seismic Desi
16-18
Original Design Completed thru Change Order # 01
Revision History
Rev # Update Reason for Revision Pages Revised
Reactions.
Date Eng.
Revised
Project Engineer: Meeram Jeelani (Fairview)
Checking Engineer: Akula Sai Krishna
Signing Engineer: Ronald Bennett, P.E
B17-2710 RC2/B-4
040-260-056
JANUARY 5, 2018
S'T'ORAGE BLDGAO ELEC
QROf ESS/04
G�
W No. C050732
� m
sT�l CIVIL
e0f �At1E4�
Iz-Zo-I�
N
V1 I 1 I 11A
�
BUILDING COMPANY ACCREDITED'
An NCI Company AC 472
December 19, 2017
SUPERIOR CONSTRUCTION
4241 EAST BRUNDAGE LANE
BAKERSFIELD, CA 93307
16-B-11185
TOM HUSING
DURHAM, CA
40'-0" x 80'-0" x 14'-0
To Whom It May Concern:
Please note -these drawings and/or calculations are not signed by the original NCI
supervising engineer. In keeping with the engineering ethics statutes please
notify all state and/or local officials of this change.
Thank you for your patience in this matter. This is a rare, but sometimes
unavoidable.occurrence in our industry and we assure you that we are handling in an
ethical manner.
This is to certify that materials for the subject structure have been designed in
accordance with the order documents, specifically as shown per the attached
Engineering Design Criteria Sheet.
Aspects of code compliance as related to use or occupancy, such as sprinkler
requirements, are not addressed by these documents.
These materials, when properly erected on an adequate foundation in accordance with
the erection drawings as supplied and using the components as furnished, will meet
the attached loading requirements.
This certification does not cover field modifications or the design of materials
not furnished by Metallic Building Systems.
The attached design criteria and calculations are to remain with and form part of
this Letter of Certification.
The calculations and the metal building they represent are the product of Metallic
Building Systems or a division of its affiliate NCI Building Systems. The engineer
whose seal appears hereon is employed by either Metallic Building Systems or a
division of its affiliate NCI Building Systems and is not the engineer of record
for this project.
Cordially,Q ROFESS/o
W.
Q�pf ESS/���
p BF F2�
Metallic Building Systems p�y� w•� �� Z
Materials for Metal Buildings No. C050732 m
An NCI Company
a K0. CQ5D73ao
2 2�
Ronald W. Bennett, P.E.
` fCALMw'
Chief Design Engineer��...Z� _
of CAIN '
12/20/17
16-B-11185
n
0
METALLIC BUILDING COMPANY
Job Number: 16-B-11185
Jobsite: DURHAM,CA 95938 Designer: MJL Checker: PNR
Revision:'A Date: 8/21/17 By: Pages Revised:
Building Code ....................... CBC 16
Risk Category ......................... II - Normal
Roof Dead Load
Superimposed .................... 2.000 psf
Collateral ....................... 3.000 psf
Roof Live Load ....................... 20.00 psf (Reducible)
Snow
Wind
Ground Snow Load (Pg)........... 0.00 psf
Snow Load Importance Factor (Is) 1.00
Flat Roof Snow Load (Pf)........ 0.00 psf
Snow Exposure Factor (Ce)....... 1.00
Thermal Factor (Ct)............. 1.00
Ultimate Wind Speed............ 110 mph
Nominal Wind Speed (Vasd)...... 85 mph (IBC Section 1609.3.1)
Serviceability Wind Speed ......72 mph
Wind Exposure Category ......... C
Internal Pressure Coef (GCpi) 0.18/-0.18
Loads for components not provided by building manufacturer
Corner Areas 24.171 psf pressure -32.167 psf suction
Other Areas 24.171 psf pressure -26.185 psf suction
These values are the maximum values required based on a 10 sq ft area.
Components with larger areas may have lower wind loads.
Seismic
Seismic Importance Factor (Ie) 1.00
Seismic Design Category......... D
Soil Site Class ................. D Stiff Soil
Ss .............................. 0.6120 g
Sds .....
0.5346 g
51 .............................. 0.2720 g
Shc .....
0.3366 g
Analysis Procedure .............. Equivalent Lateral Force
Column Line 2 TO 4
1&5
SWA&SWC
Basic Force Resisting System C4
B3
B3
Response Modification Coefficient (R) 3.25
3.25
3.25
System Over -Strength Factor (Omega) 2.5000
2.0000
2.0000
Seismic Response Coefficient (Cs) 0.165
0.165
0.165
Design Base Shear in kips (V) Transverse 4.27 Longitudinal
4.25
Basic Structural System (from ASCE 7-10 Table
12.2-1)
C4 - Steel Ordinary Moment Frames
B3 - Steel Ordinary Concentric Braced Frames
***********************************************************************
* "The design collateral load has been uniformly applied to the design*
* of the building. Hanging loads are to be attached to the purlin
* web. This may not be appropriate for heavily concentrated loads.
* Any attached load in excess of 150 pounds shall be accounted for by *
* special design performed by a licensed engineer using concentrated *
* loads and may require separate support members within the roof
* system."
***********************************************************************
r
2
08/21/17
Provide 2X2X1/8"
FB w/o back up
plate @ indicated O O O ® O
locations
,
------------------ ---------------------------- _
O I I
\F
I I
I
I I
I I
I I
1
I I
I I
I I
® I ---------- ----------- ----------- ---------- 1 O
I I
I I '
1
I I .
I
I
I I
I 1
O I 1 O
Provide sub -jambs
O3 Move FBs to otherUlf O
side of column
16-B-11185 Framing Layout 8/21/17
3
08/21/17
4
08/21/17
--------------------------------------------------------------------------------
16-B-11185 FRAMING SUMMARY:
------------
Roof
8/21/17 2:29am
PURLIN LAYOUT:
--------------
Surface Purlin Surf
Ext Stub
Purlin Total
Peak-Set_Space-
Id Type Left
Right Left
Right Rows
Space Space
Row
------- ------ -----
2 ZB 0.00
----- ----
0.00 N
----- -----
N 4
----- -----
1.33 4.68
---
4
3 ZB 0.00
0.00 N
N 4
1.33 4.68
4
PURLIN LOCATION:
----------------
Surface Purlin Surf
Id Id Offset
------ ------ ------
Space
-----
2 1 4.68
4.68
2 9.37
4.68
3 14.05
4.68
4 18.74
.4.68
20.07
1.33
3 1 1.33
1.33
2 6.02
4.68
3 10.70
4.68
4 15.39
4.68
20.07
4.68
PURLIN & EAVE STRUT:
--------------------
Surface Bay
-Purlin_Lap-
IS Flg
Eave
Id Id Part
------- -----------
Left
------
Right Strap
------ ------
Strut
--------
2 1 8X25216
2.33 0
8ES1L14
2 8X25Z16
2.33
1.33 0
8ES11,14
3 8X25216
1.33
2.33 0
8ES1L14
4 8X25216
2.33
0
8ES11,14
3 1 8X25216
2.33 0
8ES1L14
2 8X25Z16
2.33
1.33 0
8ES1L14
3 8X25Z16
1.33
2.33 0
8ES11,14
4 8X25216
2.33
0
8ES1L14
ROOF BRACING:'
------------
Bay Attach_Locate
Id Start End Type
Part
Dia
4 0.00 20.00 Rod
WR0800
0.500
20.00 40.00 Rod
WR0800
0.500
BOLT AT EAVE STRUT:
--------------
Wall Frame -Line Lap
------- Bolt
------
Id Id Type Plate
No. Type
-Size
Dia Washer
2 1 EW -
2 A325
0.500 0
2 2 RF N
2 A325
0.500 0
2 3 RF N
2 A325
0.500 0
2 4 RF N
2 A325-
0.500 0
4
08/21/17
2 5 EW - 2 A325 0.500' 0 ,
4 1 EW - 2 A325 0.500- 0
4 2 RF N 2 A325 0.500 0
4 3 RF N 2 A325 0.500 0
9 4 RF N 2 A325 0.500 0
4 5 EW - 2 A325 0.500 0
PURLIN ANTI -ROLL:
-----------------
Surf Line Ds_ARoll No.
Id Id AntiRoll Type Id Purlin Purlin Id
---- ------------------------- ------ --------------------
2 L_EW Clip w/gusset @001 1 4
2 RF Clip w/gusset @004 1 4
2 R_EW Clip w/gusset @001 1 4
3 L_EW Clip w/gusset @001 1 1
3 RF Clip w/gusset @004 1 1
3 R_EW Clip•w/gusset @001 1 1
16-B-11185 FRAMING SUMMARY: Left Endwall 8/21/17 2:29am
RAFTER:
Surf
Id Id Part Length
------ ------------ ------
Rafl 2 1OF35C12 20.07
Raft 3 l0F35C12 20.07
RAFTER SPLICE:
--------------
-Surface- ---Plate--- Bolt Bolt Bolt ---Top--- --Bottom-
Id Locate Type Width Thick Type Dia Gage Row Space Row Space
-- ------ ---- ----- ----- ----- ----- ----- --- ----- --- -----
31 0.00 M 7.50 0.375 A325 0.625 3.50 2 4.00 2 4.00
COLUMN:
Grid Base
Id Offset Line Part Length Elev
Coll 0.67 C 8F25C14 12.53 0.00
Co12 20.00 B 8F35C13 14.14 0.00 `
Co13 39.33 A 8F25C14 12.53 0.00
BASE PLATE:
----------Plate-------- -----Anchor Bolt----- Base_Clip_Bolts
Id Type Width Length Thick Type Dia Gage Row No. Type Dia
------ ---- ----- ------ ----- ----- ----- ----- --- --- ----- -----
Coll S3 7.00 8.00.0.250 GR36 0.625 3.00 1 0
Co12 S3- 7.00 8:00 0.250 GR36 0.625 3.00 1 0
Co13 S3 7.00 8.00 0.250 GR36 0.625 3.00 1 0
CAP PLATE:
-----Bolts-----
Id No. Type Dia
Coll 4 A325 0.500
Co12 4 A325 0.500
Co13 4 A325 0.500
5 .
08/21/17-
GIRT LAYOUT:
------------
Bay Bay_Offset
--Support-
----Lap----
Flg
Id Locate Type Part Start End
--- ------ ----
,Left Right
Left
Right
Rot
-------- ----- -----
1 7.50 ZF 8X25Z14 0.00 20.00
---- -----
Col Col
-----
0.00
-----
0.00
---
D
11.00 ZF 8X25Z16 0.00 20.00
Col Col
0.00
0.00
D
--- ------ ------------ ----- -----
2 7.50 ZF 8X25Z14 0.00 20.00
---- -----
Col Col
-----
•0.00
-----
0.00
---
D
11.00 ZF 8X25Z16 0.00 20.00
Col Col
0.00
0.00
D
GIRT INSIDE FLANGE BRACE:
No. Brace/Bay
1- 2
0 0
WALL BRACING:
-------------
Bay Brace_Height
Id Bot Top Type Part
Dia
1 0.00 14.14' Rod WR0800
0.500
----------------
16-B-11185 FRAMING SUMMARY: Right
Endwall•
8/21/17
2:29am
RAFTER:
Surf
Id Id Part Length
Rafl 2. 10F35C12 20.07
Raf2 3, 10F35C12 20.07
RAFTER SPLICE:
--------------
-Surface- ---Plate--- Bolt Bolt
Bolt ---Top---
--Bottom-
Id Locate Type Width Thick Type Dia Gage Row
-- ------ ---- ----- ----- ----- ----- -----
Space
Row
Space
3 0.00 M 7.50 0.375 A325 0.625
:---
3.50 ',2
-----
4.00
---
2
-----
4.00
COLUMN:
Grid
Base
Id. Offset Line Part Length
Elev
Coll 0.67 A BF25C14 12.53
0.00
Co12 20.00 B BF35C13 14.14
0.00
Co13 39.33 C 8F25C14 12.53
0.00
BASE PLATE:
----------Plate-------- -----Anchor Bolt-----
Base_Clip_Bolts
Id Type Width Length Thick Type
------ ---- ----- ------ ----- -----
Dia Gage
----- -----
Row No.
--- ---
Type
Dia
-Coll S3 7.00 8.00 0.250 GR36
0.625 3.00
1 0
-----
-----
Col2 S3 7.00 8.00 0.250 GR36.
0.625 3.00
1 0
Co13 S3 7.00 8.00 0.250 GR36
0.625 3.00
1 0
CAP PLATE:
6
08/21/17
-----Bolts-----
Id No.'Type Dia
------ --- ----- -----
Coll 4 A325 0.500
Co12 4 A325 0.500
Co13 4 A325 0.500
GIRT ,LAYOUT:
------------
Bay Bay_Offset --Support- ----Lap---- Flg
Id Locate Type Part Start End Left Right Left Right Rot
--- ------ ------------ ----- ----- ---- ----- ----- ----- ---
1 7.50 ZF 8X25Z14 0.00 20.00 Col Col. 0.00 0.00 D
11.00 ZF 8X25Z16 0.00 20.00 Col Col 0.00 0.00 D
--- ------ ------------ ----- ----- ---- ----- ----- ----- --
2 7.50 ZF 8X25Z14 0.00 20.00 Col Col 0.00 0.00 D
11.00 ZF 8X25Z16 0.00 20.00 Col Col 0.00 0.00 D
GIRT INSIDE FLANGE BRACE:
-------------------------
No. Brace/Bay
1 2
0 0
WALL BRACING:
-------------
Bay Brace_Height
Id Bot Top Type Part Dia
----- ------ ---------------------- -----
2 0.00 14.14 Rod WR0800 0.500
16-B-11185 FRAMING SUMMARY: Front Sidewall 8/21/17 2:29am
OPENING LAYOUT:
---------------
Open -----Bay----- ------- Opening _ Size ------
Id ' Id Offset Width Height Sill Note
1 2 1.50 12.00 12.00 0.00
OPENING JAMB/HEADER/SILL:
-------------------------
Open Bay
Id Id Member Offset Locate Part Length
---- --- ------ ------ ------ -------- -------
1 2 Jamb -L 1.50 0.00 8F35C14 12.00
Jamb -R 13.50 0.00 8F35C14 12.00
GIRT LAYOUT:
------------
Bay Bay_Offset --Support- ----Lap---- Flg
Id Locate Type Part Start End Left Right Left Right Rot
--- ------ ------------ ----- ----- ---- ----- ----= ----- ---
1 7.50 ZB 8X25Z13 0.00 20.00 Col Jamb 0.00 0.00 D
--- ------ ------------ ----- ----- ---- ----- ----- ----- ---
2 7.50 ZO 8X25Z16 13.50 20.00 Jamb Col 0.00 0.00 D
12.00 CO 8X35C14 0.00 20.00 Col Col 0.00 0.00 U
--- ------ ------------ ----- ----- ---- ----- ----- ----- ---
3 7.50 ZB 8X25Z16 0.00 20.00 Col Col 0.00 1.33 D
--- ------ ------------ ----- ----- ---- ----- ----- ----- ---
7
08/21/17
4 7.50 ZB 8X25Z16 0.00 20.00 Col Col 1.33 0.00 D
GIRT INSIDE FLANGE BRACE:
-------------------------
No._Brace/Bay
1 2 3 A
0 0 0 0
WALL BRACING:
-------------
Bay Brace_Height
Id Bot Top Type Part Dia
----- _ ------ ---------------------- -----
4 0.00 14.00 Rod WRO800 0.500
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
16-B-11185 FRAMING SUMMARY: Back Sidewall 8/21/17 2:29am
--------------------=---------------•--------------------------------------------
--------------------------------------------------------------------------------
GIRT LAYOUT:
------------
Bay Bay Offset --Support- ----Lap---- Flg
Id Locate Type Part Start End Left Right Left Right Rot
--- ------ ---- -------- ----- ----- ---- ----- ----- ----- ---
1 7.50 ZB 8X25Z16 0.00 20.00 Col Col 0.00 1.33 D
--- ------ ------------ ----- ----- ---- ----- ----- ----- ---
2 7.50 ZB 8X25Z16 0.00 20.00 Col Col 1.33 1.33 D
--- ------ ------------ ----- ----- ---- ----- ----- ----- ---
3 7.50 ZB 8X25Z16 0:00 20.00 Col Col 1.33 1.33 D
--- ------ ------------ ----- ----- ---- ----- ----- ----- ---
4 7.50 ZB 8X25Z16 0.00 20.00 Col Col 1.33 0.00 D
GIRT INSIDE FLANGE BRACE:
-------------------------
No. Brace/Bay
1 2 3 4
0 0 0 0
WALL BRACING:
-------------
Bay Brace_Height
Id Bot Top Type Part Dia
----- ------ ---------------------- -----
1 0.00 14.00 Rod WR0800 0.500
16-B-11185 FRAMING SUMMARY: Rigid Frame 1 8/21/17 2:29am
LAYOUT:
Type RF
No: Line • 2
Frame Line Id 2 3
Grid Line Id 2 3
MEMBER:
Surf Mem Seg Flange Flange-Web_Depth- -Plate Thickness -
Id Id 'Id Part Length Width Start End Web 0-flg I-flg
---- --- ----------- ------ ------ ----- ----- ----- ----- -----
1 1 1 13.35 5.00 9.00 13.00 0.134 0.250 0.250
8
08/21/17
2 2 2 8.35 5.00 11.00 11.00 0.134 0.250 0.250
2 2 3 10.00 5.00 11.00 11.00 0.134 0.250 0.250
3 3 4 10.00 5.00 11.00 11.00 0.134 0.250 0.250
3 3 5 8.35 5.00 11.00 11.00 0.134 0.250 0.250
4 4 6 13.35 5.00 13.00 9.00 0.134 0.250 0.250
SPLICE:
-Surface- ---Plate--- Bolt Bolt Bolt ---Top--- --Bottom-
Id•Locate Type Width Thick Type Dia' Gage Row Space Row Space•
-- ------ ---- ----- ----- ----- ----- ----- --- ----- --- -----
2 0.00 VEE 6.00 0.625 A325 0.750 3.00 2 4.00 2 4.00
3 0.00 -EE 6.00 0.375 A325 0.750 3.00 2 4.00 2 4.00
4 0.00 VEE 6.00 0.625 A325 0.750 3.00 2 4.00 2 4.00
BASE PLATE:
---Plate--------------Bolt---------- Base
Locate Type Width Thick Type Dia Gage Row Elev
---------- ---- ----- ------ ----- ----- ----- ---- -----
Lt Column P 6.00 0.375 GR36 0.750 4.00 2 0.00
Rt Column P 6.00 0.375 GR36 0.750 4.00 2 0.00
FLANGE BRACE:
-------------
Surf No.
Id Locate Side Part Clip
1 1, 1 L2X2X14G
2 1 1 L2X2X14G
2 2 1 L2X2X14G
2 3 1 L2X2X14G
2 4 1 L2X2X14G
3 1 1 L2X2X14G
3 2 1 L2X2X14G
3 3 1 L2X2X14G
3 4 1 L2X2X14G
4 1 1L2X2X14G
BEARING.STIFFENER:
------------------
Locate Width Thick
Lt Column 2.50 0.250
Rt Column 2.50 0.250
16-B-11185 FRAMING SUMMARY: Rigid Frame 2 8/21/17 2:29am
LAYOUT:
Type RF
No. Line 1
Frame Line Id 4
Grid Line Id 4
MEMBER: -
Surf Mem Seg Flange Flange-Web_Depth- -Plate Thickness -
Id Id Id Part Length Width Start End Web O-flg I-flg
---- --- ----------- ------ ------ ----- ----- ----- ----- -----
1 1 1 .13.35 5.00 9.00 13.00 0.134 0.250 0.250
2 2 2 8.35 5.00 11.00 11.00 0.134 0.250 0.250
9
08/21/17
2 2 3 10.00 5.00 11.00 11.00 0.134 0.250 0.250
3 3 4 10.00 5.00 11.00 11.00 0.134 0.250 0.250
3. 3 5 8.35 5.00 11.00 11.00 0.134 0.250 0.250
4 4 6 13.35 5.00 13.00 9.00 0.134 0.250 0.250
SPLICE:
-Surface- ---Plate--- Bolt Bolt Bolt ---Top--- --Bottom-
Id Locate Type Width Thick Type Dia Gage Row Space Row Space
2 0.00 VEE 6.00 0.625 A325 0.750 3.00 2 4.00 2 4.00
3 0.00 -EE 6.00 0.375 A325 0.750 3.00 2 4.00 2 4.00
4 0.00 VEE 6.00 0.625 A325 0.750.. 3.00 2 4.00 2 4.00
BASE PLATE:
---Plate--------------Bolt---------- Base
Locate Type Width Thick Type Dia Gage Row •Elev
---------- ---- ----- ------ ----- ----- ----- ---- -----
Lt Column P 6.00 0.375 GR36 0.750 4.00 2 0.00
Rt Column P 6.00 0.375 GR36 0.750 4.00, 2 0.00
FLANGE' BRACE :
Surf No.
Id Locate Side Part Clip
1 1 1 L2X2X14G
2 1 1 L2X2X14G
2 2 1 L2X2X14G
2 3 1 L2X2X14G
2 4 1 L2X2X14G
3 1 1 L2X2X14G
3 2 1 L2X2X14G
3 3 1 L2X2X14G
3 4 1 L2X2X14G
4 1 1 L2X2X14G
BEARING STIFFENER:
------------------
Locate Width Thick
Lt Column 2.50 0.250
Rt Column 2.50 0.250
0
10
08/21/17
w1a 11sa to . P. I fW,
Mum
_ - �+/r
A
W -C 0117 -TD -0117 d: 51FII
FRAME CROSS SECTION: FRAME UNE 2 3
4M NOTES -
. L mum =3 WIN AMII M i eau mom , wcm+ra V FIN mem Am er aro L motallic �1uNding company
SPIXM AS fim0®m JIM M ADUNDAgLpL�7��IIe 11E IW ,,��,I,
STIlCIIMI Alfie ISD ALIY AM Q AWO RIEFR W= R ml
M' 1��11� 40-"M W 77210
Ri1l1SM10 w EE oomwu m fff ISD 11E
ap p DIIHIUED TMS7 of nw mm MW MIS M law �� l0Y MSD
iD®I ImDOR 16ICaYG�BE ro Pft www" AM " Ram
we°O1DDcnwa�Ela saiDx I o �Rienm anme >a�l mclDclw aEae sol aero
9leassn sE a711@IaD al DB AIS w7r >ip WIDN WIM M 110NIA lei
2. fU FM QaEWW W lSOD9M fIWDD SAeE BE D= Mel ASD DIM wDucF Mu RASE um D A KIIW >im ■EHA ®[
s M6T7LL ME iU1H ewers ON aWM AND WnR AS SM:/h LLT2 , A %-B-11166 E7 11 1
• 11
08/21/17
57fiM UK
Nat
I 0..t
71tl Lanalb
ist-f
I W 1
12 1/E 1/4 Jr
YM W
a maIYM.
-07 6■ C. A
It 217A
653-B
i IMOD)
12
08/21/17
Ll
1�
1
11
A
IR 1/C
C
FRAME CROSS SECTION: FRAME LINE 4
F' MA �,$-;R a, „�, „�
" °" �'
metallic building company
f, �.
SFMM AS REDO= AM W,
sync UM M AM � �
r
7301 FM*, INTO M WA% VA = 4=
lAM Ql gpl� A.IE
VAEIEI® CMI BE AMMIUM BY % n[ lul -WV i6= R
ID 77Mf (113) 166 -TM EP "Me
TWOM OW 0 1N67 CI7 Thi MM CMMBLL13 01 CNA
1B1®1 ImOOR As AIMLsmm AMC
FNW= Al HM
"Ram
MOMF��C C-ncC
CNS
61BL11R4 SBiow
QSIDrA su{flml We1NL7O1
=an
6CD613O0. IIE Cp661p6 01 NR INR BIP CINW.
L NE 176D CUM= OF =OINNR7 ffAM %ft 6E GM NCI AM MM
CID COB UNE
MR"= D I NA61I 6161 rAm 66
a IMM M MK ® oI MM AM NM As g
:. r1A
f A 16-8-11186 EB A
12
08/21/17
Ref #
ED00001 X
Date Rev
Mav'17 00
Double Sub -Jamb for DBCI door
Mounting Plat
(Not by Metal
Bldg. Mfr.) ,
I
AN
I
I I I
I ' '
I I I
I I I
I ' '
II
i ii,
rI
Mounting Bracket
(Not 'by Metal �,—
Bldg. Mfr.) eader
Bolt (Not. b
Metal Bldg. Mfr.) Jamb
Job Number
16-B-11185
ub Jambs
13
08/21/17
14
08/21/17
------------
16-B-11185 Bracing Reactions Report: 8/21/17 2:29am
BUILDING BRACING REACTIONS:
---------------------------
------Reactions(k )-------
---Wall-- Col ----Wind---- --Seismic--- Panel_Shear(lb/ft)
.Loc Line Line Horz Vert Horz Vert Wind Seismic Notes
---- ----------- ----- ----- ----- ----- ------------- -----
L-EW-1, C ,B 1.28 0.94 0.61 0.45
F SW A 4 ,5 2.52 1.53 2.13 1.29
R EW 5 B ,C 1.28 0.94 0.61 0.45
B SW C 5 ,4 2.52 1.53 2.13 1.29
---- ----------- ----- ----- ----- ----- ------------- -----
Reaction values shown are unfactored. Maximum load combination factors are:
Wind : 0.60
Seismic: 0.70
16-B-11185 Additional Reactions Report: 8/21/17 2:29am
------------
Rigid Frame Column Reactions(k )
--------------------------------
Frame Col ----Dead--- Collateral ----Live--- Floor Live ----Snow---
Line Line Horz Vert Horz Vert Horz Vert Horz Vert Horz Vert
----- ------ ----- ----- ----- ----- ----- ----- ----- ----- ----- -----
2* C 0.4 1.2 0.5 1.2 1.9 4.8 0.0 0.0 0.0 0.0
2* A -0.4 1.2 -0.5 1.2 -1.9 4.8 0.0 0.0 0.0 0.0
4 C 0.4 1.2 0.5 1.2 1.9 4.8 0.0 0.0 0.0 0.0
4 A -0.4 1.2. -0.5 1.2 -1.9 4.8 0.0 0.0 0.0 0.0
Frame Col -Snow -Drift Slide -Snow Wind_Leftl Wind_Rightl Wind_Left2
Line Line Horz Vert Horz Vert Horz Vert Horz Vert Horz Vert
----- ------ ----- ----- ----- ----- ----- ----- ----- ----- -=--- -----
2* C 0.0 0.0 0.0 0.0, -4.4 -7.9 0.3 -4.8 -4.4 -4.7
2* A 0.0 0.0, 0.0 0.0 70.3 -4.8 4.4 -7.9 -0.4 -1.5
4 C 0.0 0.0 0.0 0.0 -4.6 -8:1 0.4 -4.7 -4.5 -4.8
4 A 0.0 0.0 0.0 0.0 -0-.9 -4.6 4.7 -8.0 -0.5 -1.5
Frame Col Wind_Right2-Wind_Press -Wind Suct- Wind_Longl Wind_Long2
Line. Line Horz Vert Horz Vert Horz Vert Horz Vert Horz Vert
2* C 0.'4 =1.5 0.0 0.0 0:0 0.0 -0.5 -7.0 -0.8 -5.7
2* A '4.4 -4.7 0.0 0.0 0.0 0.0 0.8 -5.7 0.5 -7.0
4 C 0.7 -1.3 0.0 0.0 0.0 0.0 -0.8 -8.7 -1.0 -7.4
4 A 5.2 -4.9 0.0 0.0 0.0 0.0 0.0 -7.0 -0.2 -8.4
Frame Col-Seis_Left--Seis_Right-Seis_Long- ----Temp--- ----Rain---
Line Line Horz Vert Horz Vert Horz Vert Horz Vert Horz Vert
2* C -0:7 -0.5 0.7 0.5 0.0 0.0 0.0 0.0 0.0 0.0
2* A -0.7 0.5 - 0'.7 -0.5 0.0 0.0 0.0 0.0 0.0 0.0
4 C -0.7 -0.5 0.7 0.5 0.0 -1.7 0.0 0.0 0.0 0.0
4 A -0.7 0.5 0.7 -0.5 0.0 -1.7 0.0 0.0 0.0 0.0
------------------------------------=-----------------------------------------
15
08/21/17
2* Frame Lines:2 3
Endwall Column Reactions(k )
-----------------------------
Frame Col Dead Collat Live Wind_Leftl Wind_Rightl Wind_Left2 `
Line Line Vert Vert Vert Horz Vert Horz Vert Horz Vert
----- ---- ----- ----- ----- ----- ----- ----- ----- ----- -----
1 C 0.3 0.2 1.6 1.3 -3.0 0.0 -0.1 1.3 -3.0
1 B 0.7 0.7 4.9 0.0 -3.8 1.3 -5.8 0.0 `-3.8
1 A 0.3 0.2 1.6 0.0 -1.1 0.0 -2.1 0.0 -1.1
Wind Wind
Frame Col Wind_Right2 Press Suct Wind_Longl Wind_Long2
Line Line Horz Vert Horz Horz Horz Vert Horz Vert
----- ---- ----- ----- ----- ----- ----- ----- ----- -----
1 _ C 0.0 -0.1 0.0 0.0 0.0 -2.0 0.2 -1.2
1 B 1.3 '-5.8 -2.7 2.9 0.2 -5.0 0.0 -4.7
1 A 0.0 72.1 0.0 0.0 0.0 -1.0 0.0 -2.1
Frame Col Seismic _Left Seismic Right
Line Line Horz Vert Horz Vert
1 C 0.8 -0.6 0.0 0.6
1 B 0.0 0.6 0.8 -0.6
1 A 0.0 0.0 0.0 0.0
----------- ---------------------------------------------------------------
Frame Col Dead Collat Live Wind_Leftl Wind_Rightl Wind_Left2
Line Line Vert Vert Vert Horz Vert Horz Vert Horz Vert
----- ---- ----- ----- ----- ----- ----- ----- ----- ----- -----
5 A 0.3 0.2 1.6 0.0 -2.1 0.0 -1.1 0.0 -2.1
5 B 0.7 0.7 -4.9 1.3 -5.8 0.0 -3.8 1.3 -5.8
5 C 0.3 0.2 1.6 0.0 -0.1 1.3 -3.0 0.0 -0.1
Wind Wind
Frame Col Wind_Right2 Press Suct Wind_Longl Wind_Long2
Line Line Horz Vert Horz Horz Horz Vert Horz Vert
----- ---- ----- ----- ----- ----- ----- ----- ----- -----
5 A 0.0 -1.1 0.0 0.0 0.0 -2.1 0.0 -1.0
5 B 0.0 -3.8 -2.7 2.9 0.0 -4.7 0.2 -5.0
5 C. 1.3 -3.0 0.0 0.0 0.2 -1.2 0.0 -2.0
Frame Col Seismic _Left Seismic Right
Line Line Horz Vert Horz Vert
----- ---- ----- ----- ----- -----
5 A 0.0 0.0 0.0 0.0
5 B 0.8 -0.6 0.0 0.6
5 C 0.0 0.6 0.8 -0.6
------------------------------------------------------------------------------
16-B-11185 Seismic Design Report: 8/21/17 2:29am
Building Data
Code =IBC 15
Length = 80.00
Width = 40.00
Left Eave Height. = 14.00
16
08/21117
Right Eave Height = 14.00
Seismic Formula
---------------
Base Shear, V = 0.667*Ie*Fa*Ss*W/R
Vmin = 0.044*Sds*Ie*W
Vmax = Shc*Ie*W/(T*R)
T(Moment_Frame)_ = 0.231
T(Braced Frame) = 0.145
Shear Force, E = Rho*V
(Rigid frame, endwall frame, wind bent, wind column & base reactions)
Shear Force, Em = Omega*V
(Wall diagonal bracing, splice at rigid frame & wind bent knee)
Note:
Applied load is
seismic
force
multiplied by load combination
Fa*Ss
=
0.802
0.1646
W =
23.59 (k )
Zone/Design Category=
D
3.88 (k )
Force,
E _
5.05 (k )
Ie
=
1.000
R =
3.25, Rho= 1.30, Omega= 2.00
Cs =
S1
=
0.272
12.91 (k )
Force,
V =
2.13 (k )
Shc
=
0.337
Force,
E =
2.76 (k )
Back
Sds
=
0.535
Cs =
0.1646
W =
Seismic
Dead Load, W
V =
2.13 (k )
Force,
Em =
4.25 (k )
--------------------
Frame
Dead =
2.00
(psf
)
Roof
Dead =
2.00
(psf
)
Collateral =
3.00
(psf
)
Roof
Total =
7.00
(psf
) Weight=
22.40
(k )
L_EW
Dead =
2.00
(psf
) Weight=
0.59
(k )
F_SW
Dead =
2.00
(psf
) Weight=
1.12
(k )
R_EW
Dead =
2.00
(.psf
) Weight=
0.59
(k )
B_SW
Dead =
2.00
(psf
) Weight=
1.12
(k )
Total =
25.83
(k )
Seismic Forces
--------------
Roof Bracing
R =
3.25, Rho= 1.30
Cs =
0.1646
W =
23.59 (k )
Force,
V =
3.88 (k )
Force,
E _
5.05 (k )
Sidewall Bracing
Front
R =
3.25, Rho= 1.30, Omega= 2.00
Cs =
0.1646
W =
12.91 (k )
Force,
V =
2.13 (k )
Force,
Em =
4.25 (k )
Force,
E =
2.76 (k )
Back
R =
3.25, Rho= 1.30, Omega= 2.00
Cs =
0.1646
W =
12.91.(k )
Force,
V =
2.13 (k )
Force,
Em =
4.25 (k )
Force,
E =
2.76 (k )
17
08/21/17
18
08/21/17
Endwall Bracing
Left
R =
3.25, Rho= •.1.30,
Omega= 2.00
Cs =
0.1646
W =
3.71 (k )
Force,
V =
0.61 (k )
Force,
Em =
1.22 (k )
Force,
E =
0.79 (k )
Right
R =
3.25, Rho=
1.30; Omega= 2.00'
Cs =
0.1646
W =
3.71 (k )
Force,
V =
0.61 (k )
Force,
Em =
1.22 (k )
Force,
E =
0.79 (k )
Rigid Frames
R =
3.25, Rho=
1.30
Cs =
0.1646
Frame 1
W =
6.17 (k )
Force,
V =
1.02 (k )
Force,
E =
1.32 (k )
Frame 2
W =
6.17 (k )
Force,
V =
1.02 (k )
Force,
E =
1.32 (k )
End Plates
Frame
R =
3.25, Omega=
2.50
Total Base Shear
Longitudinal
Force,
V =
4.25 ,(k )
Transverse
Force,
V =
4.27 (k )
18