HomeMy WebLinkAboutB17-2797 000-000-000I I ll-� Photovoltaic Labeling "All labels and warnings to comply with NFPA 70, NEC 2014, CEC 2016 and Article 690 SOLAR PHOTOVOLTAIC SYSTEMS "All permanent plates are "RED" plastic with "WHITE" engraved lettering to be fastened with 1/8" rivets" "All caution stickers are made of a reflective & water resistant material (UL 969) with "RED" background and 3/8" "WHITE" (capital) lettering" "All plaques are "BLACK" plastic with "WHITE" engraved lettering to be attached with adhesive backing" 0 Provide permanent plate on'exterior of main electrical panel: WARNING DUAL POWER SUPPLY PHOTOVOLTAIC SYSTEM © Provide permanent plate on external AC Disconnect: PHOTOVOLTAIC "AC" DISCONNECT © Provide permanent plate on either an external.or inverter integrated lockable DC Disconnect' PHOTOVOLTAIC "DC" DISCONNECT Q Provide caution sticker on inside of Main Electrical Panel: CAUTION SOLAR ELECTRIC SYSTEM CONNECTED Q Provide caution sticker on all DC Combiner Boxes and/or Junction Boxes: CAUTION SOLAR CIRCUIT QF Provide plaques on inside of DC Dicsonnect: PHOTOVOLTAIC DISCONNECT OPERATING CURRENT: AMP SHORT CIRCUIT CURRENT: AMP OPERATING VOLTAGE: VDC MAXIMUM SYSTEM VOLTAGE: VDC DC OPERATING VOLTAGES AND MAXIMUM PERMISSIBLE SYSTEM VOLTAGE ACCORDING TO INVERTER RATING PLATE. PHOTOVOLTAIC DISCONNECT WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH UNE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. a :RM17 # BUTI`E CQUNTY DEVELOPMENT SERVICES REVIEWED FOR CODE COMPLIANCE. Z4 BY_ -- WARNING DC TER INAI5 ON ARRAY SIDE MAY BE ENMM BBI V10 D3O3NNECT 5 I OPENfIIM PMMON. Off( VOLTAGE AT TERMINALS ME REMOVING CONNBMONS. UNPLUG MODULES TO COMPIETTLY REMOVE UNIT. SEE MANUAL FOR MORE INFORMATION. © Provide plaque at dedicated circuit breaker: SOLAR INVERTER OUTPUT CONNECTION , DO NOT RELOCATE THIS OVERCURRENT DEVICE HQ Provide plaque near ground fault indicator on Inverter: - WARNING ELECTRIC SHOCK HAZARD IF GROUND FAULT IS INDICATED NORMALLY GROUNDS) CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED. 0 Provide caution sticker on all interior and/or exterior conduit & raceways every 10 feet, at turns and, above & below all penetrations: CAUTION: SOLAR CIRCUIT QK Provide plaque 'at each junction box, combiner box, disconnect and device where circuits may be exposed during service: WARNING' ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PV SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED © Provide plaque at each solar AC combiner panel: Solar Combiner Only NO BREAKERS MAY BE ADDED TO THIS PANEL. IT IS NOT TO BE USED FOR POWER DISTRIBUTION TO ANY CUSTOMER LOADS' MQ Provide sticker at PV system power disconnect: PV INPUT ONLY i `1 - DEC 11 20171 : :; . �. • . - DEVELOPAGM, /�$ERVICES t. , = a 1 1 -711 y ' s a. f 747q 7 .. S _ ^�� ^ f i T ,.. +;1., .- _ �..,.�..,,: .--�_ _.,_..— _i_-a..�+L.�..iL -W,.-. —..-. , ,• i. .. 7C 7t #a. • .. • - 211 T �rSTRU T L=ONLY- = s �i„ y ;_ VIA � SSO'C,I�ATES 3 _ f 14 -114:." •71i , ;f r' ,_ .. cSlrucfurai�n`in'eers `- ..:, A 29',101" - 175 E. WILBUR ROAD, SUITE 103 -THOUSAND OAKS, CA 91360 . L • L' 2 .P- 805.496.2100 '.f- 805.496.2442 e- Vinci@VinciSE.com. * ... - � -< � , ,.. n_ e. "F •' . % it s . -C • - � `:.x' � :� , - • L • _ , • ;� .. '., :.yM .; ' _ � � _.. _ .. `. .. ' ' .PERMIT,# I .F _ BUTTE COUNTY DEVELOPMENT SERVES C i PV module typical ' t' ' a; „ . REVIEWED. FOR f .w .• . , ." 1' . • :. ., w, � . { o�.h. ._•' '• 'e .• -.. ` •..) • v 'r� • _:, . � , • _ _ ,. .. ' - .• COLD E COMPLIANCE.,.,U bolt assembly, #bl typical Pro Solar 1}" single socket tee, typical DATE •:... ; Grainger #4NXU8- .. 4i . h .. - • t _ ♦ - - ` 164 PV Rail S Pro Solar #210-0600 a - a II\j 1} single swivel socket typical Grainger #4NXW4 • ' , 11" schedule 40- • - finished grade - steel pipe, typical , 4 , ' �' TI m.: H ' n se n' undisturbed li undisturbed II - undisturbed I•t ,.ti" • ' (� _ j T - , } , it ear VIII : 'eaf,' �jjl ear," . 3125 Verniee a _ concrete min. -� Chico, CA 95973 ,�— s'-rg': *Use 2 000 si \ ' concrete min. _ r N �r►•-•,.�r ntAfr�-�,►--n,E,•�-*; t ELECTRICAL NTRACtIN An R ENERGY & SERVICE OCHICO ffice' p30) 8911 x1933 4 ko: j 4 ,.,� ap,f* gra ,. x-,(530) 8911.6749 y. CA``bc4'�454345' F , 36 W,Eaton Road Chico- CA. 973awww:chicoelectric.com BUTTE _ IMj r COUNTY • N 'DEC 11'2017 � � it-�° . ' - �; '` _ • • �' •" • �` . - r " ... • . DEVELOPMENT - �_ i i •�, - ,. �p SERVICES S C A.. ' •• ..i —.' ~; •E c 2 31117 1 0 A� 4 2 17 -;..ATRU T L. -ONLY . _ T-55.. „ s 11, s• 1 d1'WC1 S�SOC-I.:ATES ;= 1 L4'- -4 .� ,� tp /�? q 22�_n- ; , s. r = cslr'u rat Vl1C1171e21S 1 KS , T • «4 • r `+ n.' ' ' 8 29' -10-2:L ' t 22'- 175E. WILBUR ROAD, SUITE 103 HOUSAND OAKS. CA 91 60 • 4 •, - =r .- - y' j' P-'605,496.2100 f- 805.496.2442' e-.Vinci�VinciSE.com PERMIT ti DEVELOPMENT SERVICES UTTE PV module, typical .!" Bcomm • U -bolt assembly, typical - TjTF REVIEWED FOR ., t Pro Solar #.240-0178 CODE CdMIPLIANCE single socket tee, typical - • 3 `. , f+l Grainger #4NXU8 _ . 164^ PV Rail � r . � • - 'gy Pro Solar#210.0600 .. ... J :v''. '•MIN S+ - ,; • - -„ .. - .n _' .. 1.. .. ..C'-' ,_�.. ... .. .. • 1}^ single swivel socket typical Grainger #4NXW4 1}" schedule 40 • f - ' - • -''. • '�,1 •♦• - .. -finished grade _ • steel Pipe, typical im T -Hansen - Iva •'' '... " undisturbed L�1 undisturbed ; undistrthurbed '•� •3125. Ve rn i ee - u . L!•• - !. earth ea ` .. .f .!� / f� /' • - - t 7 •- •-Use2te0mns.i - ;, �. 1� ,I .. Chico; CA`95973concre. *,Use 2;000psI ►+ r --►.►n •� ,--.►n..—rn A concrete min. N ' { ELEyCtRICALCOONTRRACrINtG/�SO r)/+R ENERGYi&SERVICE '¢ , CHICO + • � _ ' . � w ' /�. � = I --I - ELECTRIC Office.���530) 891-x1.933' • • .. Fax {530) 891f6749 ' J�rWLic 4 4345�Irf M ♦ 36 W?'Eaton Ro IcoCA. 95973 .www:chlcoeleetnc.com . _•'t _ a "►�.Jtli.�t_Jitti,_Jtlrtj lti�Y�5�1/t�te` , • �. .,Y ^#. e _ . . d' •-r' a.:.. •.war •�.,.' 4-• t'- • - , _ _ _ .. a-. ..�Y' s' ♦ , ... _. _ ' k �. ASSOCIATES V1NC1 c�frucfura/ �nyineers to December 5, 2017 PERMIT# F7 B SERVICES . BUTTE COUNTY DEVELOPMENTS CES Chico Electric DEC 1 1 :ZO17, DE COMPLIANCE FOR 36 W. Eaton Road DEVELOPMENT : CO OMPLIANCE Chico, CA 95973 SERVICES ®ATE l iv T --BY �'LJ Subject: Review of minimum footing requirements Project: (0) Module. Photovoltaic Groundmount Installation (1 Array) Tim Hansen 3125 Vernice, Chico, CA 95973. V&A Project No. 12=3457 The purpose of this report, is to provide a site specific analysis of the minimum footing requirements for the photovoltaic array, groundtrac: installation at 3125 Vernice in Chico, CA 95973. 1 Based upon our review .of -the 1. Photovoltaic Array,, installed 4 modules high and:5 modules wide. The PV !tray shall have a transverse spacing of approximately 5.58 feet on center and a longitudinal spacing of 7.45 feet maximum. Based upon a wind speed of 100 mph, Exposure C, it was determined that the minimum required footing depth is 30 inches minimum below grade for the front footing and 36 inches minimum below grade for the rear:footing for a 12 inch diameter pier footing. The footing sizes are based upon the worst. casa loading due to. horizontal and vertical wind loading. Refer to attached calculations and details for additional information. Our professional services have been performed using the degree of care and skill ordinarily exercised under similar circumstances by reputable engineers practicing in this locality. No other warranty, expressed or implied, is made as to.the professional options included in this report. We hope t is ' d p p p you with the information you need at this time. Please call us '- if you have any s o s garding this report. o�Ess, Sincerely, R�c►wRo ' VINCI' CIATES No. S4411 Z .. � Exp. .12/31/17. J e InCI, S.E. F OF CAL�F� S. E. a se No. S-4411 175 E. WILBUR ROAD STE 103 THOUSAND OAKS, CA 91360 p 805.496-2100 1805.496-2442 a vinci@vincise.com DATE: 12/5/2017 VINCI $ -ASSOCIATES SHEET: Al PROJECT: Tim Hansen c3lrucfural (engineers JOB NO.: 12-3457 3125 Vernice 175 E. WILBUR ROAD,'STE 103 • THOUSAND OAKS, CA 91360 ENGR.: JRV Chico, CA 95973 p805.496.2.100 - f 805.496:2442, • evinci@VinciSE.com CLIENT: Chico Electric ■ DESIGN. DATA: 'ti WIND DESIGN CRITERIA: 20 BASIC WIND SPEED = 100 mph ' (ASCE 7-10 Risk Category 1 per Table 1.5-1 & Figure 26.5-1C) ' WIND EXPOSURE = C GROUND SNOW LOAD = 0 psf -SOLAR MODULE ARRAY DATA 1 ' Sloped Dimension of Array _ 164 in ' Angle of Array " = 30 degrees ' Slope of Array:. 6.00 :12 ' - No. of°Modules In Transverse Direction 4 pcf No of Modules in Longitudinal Direction = 5 pcf 'ti 4 Total No. of Modules in Project, _ 20 Transverse'Post Spacing, = 5.58 ft ' Longitudinal Post Spacing - 7.45 ft• Number of supports -Transverse Direction _ 2 Diameter of Pier Footing, = 12 in Number:of Arrays = 1 ' Array Uniform Load: = 2.8 psf ' SOIL DESIGN CRITERIA (Based upon Chapter18of CBC) Allowable Soil Bearing Pressure = 1500 .psf ' Allowable Soil Lateral Bearing = _ 200 pcf Allowable Shaft Skin Friction / Cohesion : = 130 pcf r INPUT DATA�; Exposure category (B, C or D) Importance factor, 1.0 only, (Table 1.5-2) h = 1.00 �I Basic wind speed (ASCE 7-10 26.5.1) ;) V = d L100' mph - ' Topographic factor (26.8 & Table 26.8-1) K,� _ ,� is 0}v Flat slope p Height of mean roof h - C -5 5, .' ft , f Roof slope • 6,00. 12 f ! Roof length L = 0 ft G Roof horizontal projected width ? B = 0; ft - °' Effective area of component / cladding ti A = �'A O>•' ft2 8, (pro) aol Ir' - DESIGN SUMMARY 1. Main Wind -Force Resisting System Max horizontal force / base shear from roof = 1.52 kips . + X0:15 kips (eave & columns increasing) vy E 1.68 kips 't Max vertical download force (+ = 3.05 kips _ Max vertical uplift force = 2.65 kips - Max moment at centroid of base from roof = 1 10.65 ft -kips p ' + 107; ft -kips (eave & columns increasing)} E 11.72 ft -kips ti i 2. Component and Cladding Elements +" Max inward pressure '; = 75 psf if Max net outward pressure = 74 psf u v, a r ANALYSIS c. Velocity pressure qh = 0.00256 Kh Kn Kd V2 + 18.50 psf where: qh = velocity pressure at mean roof height, h. (Eq. 28.3-1 page 298 & Eq. 30.3-1 page 316) A Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 28.3-1; pg 299) = 0.85 Kd = wind directionality factor. (Tab. 26.6-1, for building, page 250). = 0.85 h = height of mean roof i} = 5.00 ft Main Wind -Force Resisting System (Sec. 27.4.3) + p=ghGCN F=pAr where: G = gust effect factor. (Sec. 26.9)0.85=: 0 = roof angle = 26,57 . degree y < s 45 deg. [Satisfactory] Af = roof actual area. , z = 55.9 ft2, windward = 55.9 , ft2, leeward CN = net force coefficients. (Fig. 27.4-4; page 267) • -11) Check Fig. 27.4-4 limitation h / B = 0.50 within [0.25 , 1.0] [Satisfactory] 0 a 'I WIND TO BOTTOM, y= 0° CLEAR FLOW OBSTRUCTED WIND TO TOP, y= 180° 16 CLEAR FLOW I OBSTRUCTED. AAPROJECT: 1V_`k rra Ground Mount roJectAddress CdyState L ' 'fir' PAGE:CLIENT: DESGN BY5-3457 -1.71 -1.50 -1.75 DATE. 12X05/17 REVIEW BY: 10.55 , Wind An-"`al'vstsfor:Open-Structure;(Solar,Panels};Based on ASCE;? 201Q`/2013CBC•N�+i�L<, *� INPUT DATA�; Exposure category (B, C or D) Importance factor, 1.0 only, (Table 1.5-2) h = 1.00 �I Basic wind speed (ASCE 7-10 26.5.1) ;) V = d L100' mph - ' Topographic factor (26.8 & Table 26.8-1) K,� _ ,� is 0}v Flat slope p Height of mean roof h - C -5 5, .' ft , f Roof slope • 6,00. 12 f ! Roof length L = 0 ft G Roof horizontal projected width ? B = 0; ft - °' Effective area of component / cladding ti A = �'A O>•' ft2 8, (pro) aol Ir' - DESIGN SUMMARY 1. Main Wind -Force Resisting System Max horizontal force / base shear from roof = 1.52 kips . + X0:15 kips (eave & columns increasing) vy E 1.68 kips 't Max vertical download force (+ = 3.05 kips _ Max vertical uplift force = 2.65 kips - Max moment at centroid of base from roof = 1 10.65 ft -kips p ' + 107; ft -kips (eave & columns increasing)} E 11.72 ft -kips ti i 2. Component and Cladding Elements +" Max inward pressure '; = 75 psf if Max net outward pressure = 74 psf u v, a r ANALYSIS c. Velocity pressure qh = 0.00256 Kh Kn Kd V2 + 18.50 psf where: qh = velocity pressure at mean roof height, h. (Eq. 28.3-1 page 298 & Eq. 30.3-1 page 316) A Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 28.3-1; pg 299) = 0.85 Kd = wind directionality factor. (Tab. 26.6-1, for building, page 250). = 0.85 h = height of mean roof i} = 5.00 ft Main Wind -Force Resisting System (Sec. 27.4.3) + p=ghGCN F=pAr where: G = gust effect factor. (Sec. 26.9)0.85=: 0 = roof angle = 26,57 . degree y < s 45 deg. [Satisfactory] Af = roof actual area. , z = 55.9 ft2, windward = 55.9 , ft2, leeward CN = net force coefficients. (Fig. 27.4-4; page 267) • -11) Check Fig. 27.4-4 limitation h / B = 0.50 within [0.25 , 1.0] [Satisfactory] 0 a 'I WIND TO BOTTOM, y= 0° CLEAR FLOW OBSTRUCTED WIND TO TOP, y= 180° 16 CLEAR FLOW I OBSTRUCTED. CASE CNw CNS CNw CNS CNw CNS CNw CNL 26.57 A -1.66 -1.71 -1.50 -1.75 1.92. 1.96 10.55 , -1.00 S -26.14 -26.86 -23.58 -27.58 30.14 30.86 8.71 -15.72 i s -1.46 -1.50 -1.32 -1.54 1.68 1.72 0.49 -0.88 B -2.45 -0.41 -2.30 -1.01 2.42 0.86 1.46 0.05 S ;Fk -38.58 -6.42 -36.16 -15.85 31 13.56 22.99 0.85 i s 2.16 -0.36 2.02 0.89 2.12 0.76 1.29 0.05 a 'I IY h IY DATE: 12/5/2017 VINCI & A S S O C' 1 A T E S SHEET: A3 PROJECT: Tim Hansen cSlruclura/ (engineers JOB NO.: 09-3457 3125 Vernice 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.: JRV ' x Chico, CA 95973 a 805.496.2100 • f 805.496.2442 •,e vincf@YnciSE.com CLIENT: Chico Electric - ' FOOTING DESIGN - PV Sloped Dimension: 164 in TYP'iCALAR Y PV Array Angle: 30degrees Post Spacing: 7.45 ft ' No. of Supports: 2 Footing Diameter (d): 12 in MAXIMUM VERTICAL FORCE: - 3.05 k /(10 z 10.0) = .30.50 psf x 0.6 = 18.30 psf § r MAXIMUM UPLIFT FORCE: 2.65 k :0 / (10.0 x 10.0) = 26.50 psf x 0.6 = 15.90 psf ASD Factor GROUNDTRAC SYSTEM CAST INTO EARTH ' Maximum Vertical Load: (Worst Case: DL+ Wind) P = 18.30 psf + 2.8 psf DL + - 0 psf snow 21.10 psf P = 21.10 psf x ( 142 " /12"/ft) x ( 89.4 " /12"/ft) = 1860 lbs fort Supports ' P = 930 lbs/footing ' Try 12" diameter footing Soil Bearing.= 930 . / (p x 0.50) = 1184.9 psf << , ' 1995 psf ' 1500 psf x 1.33 (CBC Table 1806.2) Maximum Uplift Load: Therefore O.K. P = 15.90 , psf - V 2.8 psf DL = 13.10 psf P = 13.1 psf x ( 142 " '/12"/ft) x ( _ . 89.4 " /12"/ft) = 1155 lbs for Supports ' P = 578 lbs/footing Try 12" diameter x 30 " footing w Allowable uplift = Concrete DL+ Soil Cohesion ( 130 psf x 1.33) per CBC Table 1806.2 ' ' ( (n x (d/2)2) x 150 pcf x 2.5 ft ],+ ( (TE x d) x 2.54 ft x 172.9 psf] = 1678 lbs Design Ratio = r ( 1,678 lbs / 578 lbs.) = 2.9 Therefore O.K. r s • d GOVERNS >>> Try d = t' S1 @ (1/3)d DATE: 12/5/2017 V I %1 C I & ASSOCIATE'S SHEET: A4 (ft) PROJECT_: Tim Hansen j cSlruclura/ 6nyineers Job NO.: 09-3457 3125 Vernice ns E! WILBUR ROAD, STE 103 •THOUSAND OAKS, CA 91360 ENGR.: JRV t, Chico, CA 95973 p805.496.2100 • f805.496.2442 • e vinci@VinciSE.com' ") C(11C0 Electric ' CLIENT: DESIGN OF PIER FOOTINGA POST CHECK t. t {..:. •v �'i' "'moi.-�--a+' . � ONTPOST WIND 1.504 3.12 1.79 Post Spacing: 7.45 � ft 1.294 2.83 Number of Columns: 2 ' 187 1.135 Horizontal Load: 10.1 psf 2.29 Exposed wind surface 3 ft 1.011 2.42 -DESIGN BASED UPON NON -CONSTRAINED CBC FORMULA' (CBC Section 1807.3.2.1) 26'r256 d = (A)2) (1 ( 1 + (4.36h/A)) 5)) A = (2.34 P) / (S1 b)' 4� P 2.14 t P = y 94 lbs , =,10.1 psf x 7.5 ft x 3 ft / 2 columns h = 3.08 3h ' ft (Average Height) S1 = it 266 psf/ft x (d/3) (includes 1.33 increase for wind) h r b 12 in (diameter or diagonal of square) d GOVERNS >>> Try d = t' S1 @ (1/3)d A , Calc d (ft) (Psf) ? (ft) t, 1.54 141 1.504 3.12 1.79 164 1.294 2.83 2.04 t 187 1.135 2.60 _ 2.29 210 1.011 2.42 233 t O'912H#f2 26'r256 79,,�� 0.830 2.14 DESIGN COLUMN f- Mcol = Ph = 289 ft -lbs 3 S..]= Mc / Fb = 4. 0.15 in Fb = 0.66 x 35,000 psi ASTM A53, Gr B . Y »»> USE: 1=1/2" Schedule 40 Pipe S 0.31 -in3 with 12 inch diameter x 30 inch MIN. deep concrete footing. ., i t, DESIGN COLUMN f- Mcol = Ph = 289 ft -lbs 3 S..]= Mc / Fb = 4. 0.15 in Fb = 0.66 x 35,000 psi ASTM A53, Gr B . Y »»> USE: 1=1/2" Schedule 40 Pipe S 0.31 -in3 with 12 inch diameter x 30 inch MIN. deep concrete footing. ., i ' DATE 12/5/2017 PROJECT: Tim Hansen ' 3125 Vernice Chico, CA 95973 'CLIENT: Chico Electric VINCI & ASSOCIATES SHEET: 61rucfur¢i Crz9ineers JOB NO 175 E. WILBUR ROAD, STE 103 - THOUSAND OAKS, CA 91360 ENGR.: p805.496.2100 • f805.496.2442 • evinci@VinciSE.com ' .DESIGN OF PIER FOOTING & POST CHECK WWI}EAR :POST 1 Post Spacing: 7.45 ft Number of Columns: 2 Horizontal Load: 10.1 psf 1 Exposed wind surface 3 ft -DESIGN BASED UPON NON -CONSTRAINED CBC FORMULA: ' (CBC Section 1807.3.2.1) d = (A/2) (1 + ( 1 + (4.36h/A) )^.5)) 1 P 1 h d GOVERNS >>> DESIGN COLUMN Mc = Ph = P = h = S1 = b = A = (2.34*P)/(S1 -b) Ac Uy -31+01 JRV 94 lbs = 10.1 psf x 7.5 ft x 3 ft / 2 columns 6.28 ft (Max Height) 266 psf/ft x (d/3) (includes 1.33 increase for wind) 12 in (diameter or diagonal of square) Try d = 4 (ft) S1 @ (113)d (Psf) A Calc d (ft) 2 183 1.158 3.45 2.25 206 1.029 3.22 2.5 229 ' 0.927 3.02 2.75 252 0.842 2.86 3 275 Q.77t24 � 2*72 3.25 298 0.713 2.59 ' 589 ft -lbs S� = M.I / Fb 0.31 in3 Fb = 0.66 x 35,000 psi ASTM A53, Gr B 1 »»> USE: 1-1/2" Schedule 40 Pipe S = 0.31 in with 12 inch diameter x 36 inch MIN. deep concrete footing. ■ i REC TWINPEAK 25 72 SERIES PREMIUM SOLAR PANELS 100% MADE IN SINGAPORE REC TwinPeak ZS 72 Series solar panels feature an innovative design with high efficiency and an industry- leading lightweight, yet robust construction, enabling customers to get the most out of the installation area. Combined with the product quality and reliability of a strong and established European brand, REC TwinPeak ZS 72 panels are ideal for commercial rooftops worldwide. rY DMLOPMENTSEWCES MEWED FOR COMPLIANCE IX8:17 ?7 PC1./FILE. 00 -7>0=07H i NOVEMBER :2 U17 s 'GRN aViN T So L A Rry INTEGRATED MANUFACTURING IN SINGAPORE WAFERS CELLS MODULES 3 2 a REC TWINPEAK',.25 72 SERIES � � haul ^ ►+ oaslayl r 1 T a` .. =. =(471 1 ►;yf�t�at ��assms� ,. . MIMI - � r =rm ( 9Y5 �31bi - - - Es All measurements in mm lin) Y ► ELECTRICAL DATA @ STC Product Code*: RECxxxTP25 72 Nominal Power-PA7Pp(Wp) 1 330 335 340 345 350 355 ..................................................................................................... WattClassSorting-(W) ' -0/+5 -0/+5 ! -0/+5 • -0/+5 -0/+5 -0/+5 ...................................................................................... _.............................................................................................................................. Nominal Power Voltage -V,,'pIV) 38.1 r 38.3 ' 38.5 38.7 38.9 - 39.1 .. _..._ ._.....,..... _._.,..., .._....._...... ................................................................. ........................... _......................................_............ Nominal Power Current- 1,,pp(A) 8.67 8.75 8.84 , 8.92 9.00 , 9.09 _.........................................................._.....:....:..............._.....:..............._...:........,....._....:......................-.....:...............I.............................. Open Circuit Voltage-Voc(V) 46.0 46.2 46.3: ' 46.5 46.7 , 46.8 _......._,_ ._.._..._..,....... ........ ......................... ......................... _....................... ................ ........ .......................... ShortCircuitCurrent- Isc(A) 9.22 , 9.52 ' 9.58 9.64 9.72 - 9.78 .................. ...............................................................................................:..........................:..................................................,.................. ...,... Panel Efficiency(%) .16.5 16.7 16.9 - 17.2 17.4 17.7 ................................................................_..:...:....,:..........................................:.............,.....,.......................:.............................._............ Values at standard test conditions STC (airmass AM 1.S, irradiance 1000 W/m', cell temperature 77"F (25"C). ' At low irradiance of 200W/m°(AM I.Sand cell temperature 77°F(25"C))atleast 95%ofthe STC module efficiency will beachieved. " •'xxx indicates the nominal power class (P„,) at STC, and can be followed by the suffix XV for modules with a 1500 V maximum system raft . r ELECTRICAL DATA @ NOCT Product Code*: RECxxxTP2S 72 Nominal Power PMPP(Wp) 244 252 r •257 260 264 ., - 268 ........._... _..................--,..........................:............................................... ......_............................. ._ NominaIPow erVol tage V,,,p (V) 1, 3 4. 9 3 5. 5 3 5. 7 3 5. 8 3 6. 0 3 6. 2 Nominal PowerCurrent-IMpp(A) .6.99 7.10 7.19 7.25 7.32 7.39 ..........................................................................._.... ....................................................:...................................... :....... ......................... . Open CircuitVoltage-Vac(V) 42.3 ' ., 42.8 .. 42.9 43.1 43.2 43.3 _.. _ _...._.. ........................ .......................................... .................. _................................................... - Short CircuitCurrent-Q,(A) ' ` 7.44 , • �: 7.74 "' 7.79 7.84 ' 7.90 , 7.95 .. •_........._._.........................., _.. _..................................... ,............. ......................... ........................ ......................... ........................ .. - Nominal cell operating temperature NOCT (800 W/m', AM 1.5, windspeed 1 m/s, ambient temperature 68"F(20"C). 'xxxindicates thenominalpowerclass(P„pp)atSTC,and can be followed by the suffix XVformoduleswitha1500Vmaximumsystemrating. CERTIFICATION w i 10 year product warranty. SA® DVE r 25 year linear power output warranty C �1 US (max.degressioninperformanceof0.7%p.a.). i " ' UL1703, Fire classification: Type l(ISOOVXV):Type 2(1000V); IEC 61215, IEC 61730, IEC 62804 (PID), IEC 62716 (Ammonia), IEC 61701 (Salt Mist level 6),15 0 11925-2 (C lass E) ISO 9001:2015, ISO 14001:2004, OHSAS 18001:2007 r EFFICIENCY Q YEAR PRODUCT WARRANTY YEAR LINEAR POWER 25 OUTPUT WARRANTY oU� US IMPORT DUTY FREE Nominal Operating Cell Temperature(NOCT) 44.6°C(t2°C) Temperature Coefficient ofP,,,Pp -0.36%/"C Temperature Coefficient of Voc -0.30 %/"C Temperature Coefficient oflsc 0.066%/°C Cell type: 6 strings of 24 REC HC multicrystalline PERC Glass: 0.13"(3.2 mm) solar glass with anti -reflection surface treatment Back Sheet: Highly resistant polyester Frame: Anodized aluminum (silver) Supportbars: Anodized aluminum (bonded to backsheet) Junction Box: IP67 rated with 3 bypass diodes 12 AWG (4 mm2) PV wire, 47"+47" (1.2 m+1.2 m) Connectors: TonglinTL-CableDlS-F,12AWG(4mm2) Origins: Silicon: Made in USA &Norway Wafer/Cell/Module: Made in Singapore Operational Temperature: -40...+185"F(-40...+85"C) Maximum System Voltage: 1000V/1500V' *Dependent on product type Design Load: (+) 75.21bs/ft2 (3600 Pa) Design Load: (-) 33.4 lbs/ft2 (1600 Pa) Referto installation instructions Max Series Fuse Rating: 20A Max Reverse Current: 20A , MECHANICAL DATAc 4 iu Dimensions: 78.9"x39.4"x1.2'(2005x1001 x30 mm) Area: 21.6 ft2 (2.01 m2) Weight: 48.5 lbs (22 kg) LL Z Note[ Specifications subject to change without notice. REC " www.recgroup.com . MIMI - � r =rm ( 9Y5 �31bi - - - Es All measurements in mm lin) Y ► ELECTRICAL DATA @ STC Product Code*: RECxxxTP25 72 Nominal Power-PA7Pp(Wp) 1 330 335 340 345 350 355 ..................................................................................................... WattClassSorting-(W) ' -0/+5 -0/+5 ! -0/+5 • -0/+5 -0/+5 -0/+5 ...................................................................................... _.............................................................................................................................. Nominal Power Voltage -V,,'pIV) 38.1 r 38.3 ' 38.5 38.7 38.9 - 39.1 .. _..._ ._.....,..... _._.,..., .._....._...... ................................................................. ........................... _......................................_............ Nominal Power Current- 1,,pp(A) 8.67 8.75 8.84 , 8.92 9.00 , 9.09 _.........................................................._.....:....:..............._.....:..............._...:........,....._....:......................-.....:...............I.............................. Open Circuit Voltage-Voc(V) 46.0 46.2 46.3: ' 46.5 46.7 , 46.8 _......._,_ ._.._..._..,....... ........ ......................... ......................... _....................... ................ ........ .......................... ShortCircuitCurrent- Isc(A) 9.22 , 9.52 ' 9.58 9.64 9.72 - 9.78 .................. ...............................................................................................:..........................:..................................................,.................. ...,... Panel Efficiency(%) .16.5 16.7 16.9 - 17.2 17.4 17.7 ................................................................_..:...:....,:..........................................:.............,.....,.......................:.............................._............ Values at standard test conditions STC (airmass AM 1.S, irradiance 1000 W/m', cell temperature 77"F (25"C). ' At low irradiance of 200W/m°(AM I.Sand cell temperature 77°F(25"C))atleast 95%ofthe STC module efficiency will beachieved. " •'xxx indicates the nominal power class (P„,) at STC, and can be followed by the suffix XV for modules with a 1500 V maximum system raft . r ELECTRICAL DATA @ NOCT Product Code*: RECxxxTP2S 72 Nominal Power PMPP(Wp) 244 252 r •257 260 264 ., - 268 ........._... _..................--,..........................:............................................... ......_............................. ._ NominaIPow erVol tage V,,,p (V) 1, 3 4. 9 3 5. 5 3 5. 7 3 5. 8 3 6. 0 3 6. 2 Nominal PowerCurrent-IMpp(A) .6.99 7.10 7.19 7.25 7.32 7.39 ..........................................................................._.... ....................................................:...................................... :....... ......................... . Open CircuitVoltage-Vac(V) 42.3 ' ., 42.8 .. 42.9 43.1 43.2 43.3 _.. _ _...._.. ........................ .......................................... .................. _................................................... - Short CircuitCurrent-Q,(A) ' ` 7.44 , • �: 7.74 "' 7.79 7.84 ' 7.90 , 7.95 .. •_........._._.........................., _.. _..................................... ,............. ......................... ........................ ......................... ........................ .. - Nominal cell operating temperature NOCT (800 W/m', AM 1.5, windspeed 1 m/s, ambient temperature 68"F(20"C). 'xxxindicates thenominalpowerclass(P„pp)atSTC,and can be followed by the suffix XVformoduleswitha1500Vmaximumsystemrating. CERTIFICATION w i 10 year product warranty. SA® DVE r 25 year linear power output warranty C �1 US (max.degressioninperformanceof0.7%p.a.). i " ' UL1703, Fire classification: Type l(ISOOVXV):Type 2(1000V); IEC 61215, IEC 61730, IEC 62804 (PID), IEC 62716 (Ammonia), IEC 61701 (Salt Mist level 6),15 0 11925-2 (C lass E) ISO 9001:2015, ISO 14001:2004, OHSAS 18001:2007 r EFFICIENCY Q YEAR PRODUCT WARRANTY YEAR LINEAR POWER 25 OUTPUT WARRANTY oU� US IMPORT DUTY FREE Nominal Operating Cell Temperature(NOCT) 44.6°C(t2°C) Temperature Coefficient ofP,,,Pp -0.36%/"C Temperature Coefficient of Voc -0.30 %/"C Temperature Coefficient oflsc 0.066%/°C Cell type: 6 strings of 24 REC HC multicrystalline PERC Glass: 0.13"(3.2 mm) solar glass with anti -reflection surface treatment Back Sheet: Highly resistant polyester Frame: Anodized aluminum (silver) Supportbars: Anodized aluminum (bonded to backsheet) Junction Box: IP67 rated with 3 bypass diodes 12 AWG (4 mm2) PV wire, 47"+47" (1.2 m+1.2 m) Connectors: TonglinTL-CableDlS-F,12AWG(4mm2) Origins: Silicon: Made in USA &Norway Wafer/Cell/Module: Made in Singapore Operational Temperature: -40...+185"F(-40...+85"C) Maximum System Voltage: 1000V/1500V' *Dependent on product type Design Load: (+) 75.21bs/ft2 (3600 Pa) Design Load: (-) 33.4 lbs/ft2 (1600 Pa) Referto installation instructions Max Series Fuse Rating: 20A Max Reverse Current: 20A , MECHANICAL DATAc 4 iu Dimensions: 78.9"x39.4"x1.2'(2005x1001 x30 mm) Area: 21.6 ft2 (2.01 m2) Weight: 48.5 lbs (22 kg) LL Z Note[ Specifications subject to change without notice. REC " www.recgroup.com r EFFICIENCY Q YEAR PRODUCT WARRANTY YEAR LINEAR POWER 25 OUTPUT WARRANTY oU� US IMPORT DUTY FREE Nominal Operating Cell Temperature(NOCT) 44.6°C(t2°C) Temperature Coefficient ofP,,,Pp -0.36%/"C Temperature Coefficient of Voc -0.30 %/"C Temperature Coefficient oflsc 0.066%/°C Cell type: 6 strings of 24 REC HC multicrystalline PERC Glass: 0.13"(3.2 mm) solar glass with anti -reflection surface treatment Back Sheet: Highly resistant polyester Frame: Anodized aluminum (silver) Supportbars: Anodized aluminum (bonded to backsheet) Junction Box: IP67 rated with 3 bypass diodes 12 AWG (4 mm2) PV wire, 47"+47" (1.2 m+1.2 m) Connectors: TonglinTL-CableDlS-F,12AWG(4mm2) Origins: Silicon: Made in USA &Norway Wafer/Cell/Module: Made in Singapore Operational Temperature: -40...+185"F(-40...+85"C) Maximum System Voltage: 1000V/1500V' *Dependent on product type Design Load: (+) 75.21bs/ft2 (3600 Pa) Design Load: (-) 33.4 lbs/ft2 (1600 Pa) Referto installation instructions Max Series Fuse Rating: 20A Max Reverse Current: 20A , MECHANICAL DATAc 4 iu Dimensions: 78.9"x39.4"x1.2'(2005x1001 x30 mm) Area: 21.6 ft2 (2.01 m2) Weight: 48.5 lbs (22 kg) LL Z Note[ Specifications subject to change without notice. REC " www.recgroup.com Cell type: 6 strings of 24 REC HC multicrystalline PERC Glass: 0.13"(3.2 mm) solar glass with anti -reflection surface treatment Back Sheet: Highly resistant polyester Frame: Anodized aluminum (silver) Supportbars: Anodized aluminum (bonded to backsheet) Junction Box: IP67 rated with 3 bypass diodes 12 AWG (4 mm2) PV wire, 47"+47" (1.2 m+1.2 m) Connectors: TonglinTL-CableDlS-F,12AWG(4mm2) Origins: Silicon: Made in USA &Norway Wafer/Cell/Module: Made in Singapore Operational Temperature: -40...+185"F(-40...+85"C) Maximum System Voltage: 1000V/1500V' *Dependent on product type Design Load: (+) 75.21bs/ft2 (3600 Pa) Design Load: (-) 33.4 lbs/ft2 (1600 Pa) Referto installation instructions Max Series Fuse Rating: 20A Max Reverse Current: 20A , MECHANICAL DATAc 4 iu Dimensions: 78.9"x39.4"x1.2'(2005x1001 x30 mm) Area: 21.6 ft2 (2.01 m2) Weight: 48.5 lbs (22 kg) LL Z Note[ Specifications subject to change without notice. REC " www.recgroup.com Operational Temperature: -40...+185"F(-40...+85"C) Maximum System Voltage: 1000V/1500V' *Dependent on product type Design Load: (+) 75.21bs/ft2 (3600 Pa) Design Load: (-) 33.4 lbs/ft2 (1600 Pa) Referto installation instructions Max Series Fuse Rating: 20A Max Reverse Current: 20A , MECHANICAL DATAc 4 iu Dimensions: 78.9"x39.4"x1.2'(2005x1001 x30 mm) Area: 21.6 ft2 (2.01 m2) Weight: 48.5 lbs (22 kg) LL Z Note[ Specifications subject to change without notice. REC " www.recgroup.com REC " www.recgroup.com .. Data Sheet Enphase Microinverters ` j `-u� - The high-powered'smart grid -ready, Ennhase M R {� ' °, Enphase IQ 6 Micro"and Enphase IQ 6+Micro'"� IQ•6 and 1Q t6+ . ' dramatically simplify the installation process while achieving the highest efficiency for module -level , M i c ro i nve rte rS power electronics. l r t , Part of the Enphase IQ System, the IQ 6 and IQ 6+ Micro integrate seamlessl •with the Enphase ` IQ Envoy', Enphase Q Aggregator'M, Enphase IQ ' ! Battery'",.and the Enphase Enlighten'"" monitoring and analysis software. - The IQ'6 and IQ 6+ Micro'extend the reliability - E standards set•forth by previous generations and • ,.r under o over a million hours of ower -on testin� 9 p 9,' t ' ..,. , enabling_ Enphase to provide an. industry-leading . •• ` warranty of up to,25 years. Easy to Install ' i ..�. -'Lightweight and simple _ - - Faster installation with improved two -wire cabling ♦ Built-in rapid shutdown compliant (NEC 2014 & 2107) ` ` . Productive and Reliable optiTized.for high powered 60 -cell and 72-cell* moduies ' i More than a million hours of testing Class ll'double-insulated enclosure ` . UL listed Smart Grid Ready' '. Complies with fixed power factor, voltage and ' frequency ride through requirements • F Remotely updates to respond to changing grid requirements , Configurable foi varying grid profiles • Meets CA Rule 21 (UL'1741-SA) The 19 6+ micro is required to support 72 -cell modules n�,, To learn more about Enphase offerings, visit enphase.com EN PHAS E.� Enphase IQ 6'and IQ 6+ Microinverters ' INPUT DATA (DC) IQ6-60-2-US,/ IQ6-6075-US IQ6PLUS-72-2-111.11S / IQ6PLUS-72-5-US .LCommonly used module pairings'. 195 W 2330 W + ,� 4 , a."- � 235 W --400 W + Module compatibility, 60-cell PV modules only ; ' 60-cell and 72-cell PV modules Maximum input DC voltage 48 Y, Peak power tracking voltage ' .27V-37V ' 27V-45V 6pirating range 16V-48V - --716 V - 62 V r Min/Max start voltage 22 V / 48 V 22 V / 62 V ` Max DC short circuit current (module Is—c),, ,', 15 A ' ° -` ` 15 A •; '_' ' r Overvoltage class DC port DC port backfeed under singlefault 0 A -, O A I PV array configuration ; ; 1.x 1 ungrounded array; No additional DC side-protection required; ° AC side protection requires max 20A per Branch circuit OUTPUT DATA (AC) , IQ 6 Microinverter ' IQ 6+ Microinverter Peak output power " " 240VA " .� 290 VA-, 1 - Maximum continuous output power 230 VA . _ 280 VA Nominal (L-L) voltage/range2 240 V / 21.1-264 V 208 V / 183-229 V _ : 240 V / 211-264 V 208 V / 183429 V , Maximum continuous output current 0.96 A 1.11 A 1.17 A 1.35 A ..Nominal frequency 60 Hi { •60 Hz Extended frequency range ; 47 - 68 Hz r 47 - 68 Hz Power factor at rated power 7 1:0 r 1.0 ` Maximum units per 20 A (UL) branch circuit 16(240 VAC) 13 (240 VAC) 14 (208 VAC) 11 (208 VAC) Overvoltage class AC port ' ci• t III v III . w AC port backfeed under single fault ^. 0 A r OA, ` Power factor (adjustable) ; s,., 0;7.leading '.. 0.7 lagging 0.7,Iead6_g ... 0.7 lagging EFFICIENCY * @240 V: @208 V @240 V @208 V { CEC weighted efficient '` `' 9 Y'.:.t t.:F 97.0q° <.. 97.0 °io ; ;: - 97.0 % - ° 97.01°•� MECHANICAL DATA - ;. L Ambient temperature range -40°C to+650C- Relative humidity range I' , 4% to 100% (condensing) ; Connector-type , .. 7 MC4 (-2-US) or Amphenol H4 UTX (-5-US) Dimensions (WxHxD)' 219 mm 091 mm x 37.9 mm (without bracket) Weight 1.5 kg (3.3 lbs) ; Cooling Natural convection - No fans > Approved for wet locations + 7777— Pollution Pollution degree PD3 +. Enclosure' Class Ildouble-insulated _ 77 7t Environmental category / UV exposure rating Outdoor - NEMA 250, type 6 (IP67) , FEATURES Communication- t Power line a . " ,• ,i . s� ` Monitoring, Enlighten Manager and MyEnlighten monitoring options ' Compatible with Enphase IQ Envoy ' Disconnecting means The DC connectorhas been evaluated and approved by UL for use as theload-break disconnect ' required by NEC 690. r Compliance CA Rule 21 (LIC 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, fi CAN/CSA-C22.2 NO. 107.1-01•. This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and _ ' NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems; for AC and DC conductors, when installed according manufacturer's instructions." 1. No enforced DC/AC ratio. See the compatibility calculator at enph6se.com/en-us/support/module-combatibmlity. 2. Nominal voltage range can be extended beyond nominal if required by the utility. * • { ` - To learn more about Enphase offerings, visit enphasexom x. © 2017 Enphase Energy. All rights reserved. All trademarks or brandsused are-the property of Enphase Energy, Inc. • E N P H AS E. 2017-08-21 ` Data Sheet Enphase Q Cable Accessories Enphase Q Aggregator The Enphase Q Aggregator'" and Enphase Q Cable" are part of the sixth generation Enphase IQ System"'. and Q Coble Accessories These accessories provide simplicity, reliability, and faster installation times. I' Enphase Q Aggregator • Reduces electrical labor and eliminates wire nuts for safer, faster installations • Aggregates up to three fully populated 20A branch circuits • Supports solar arrays of up to 11.5 kW with a single rooftop aggregator l _ Enphase Q Cable • Two -wire, double -insulated Enphase Q Cable is 50% lighter than the previous generation r . Enphase cable t New cable numbering and plug and play connectors speed up installation and simplify wire management • Link connectors eliminate cable waste c Field-Wireable Connectors • Easily connect Q cables on the roof without complex wiring . • Make connections from any open connector and center feed any section of cable within branch limits • Available in male and female connector tvaes To learn more about Enphase offerings, visit enphase.com v E N P H AS E. -4 . Enphase Q Cable'Accessones + + - A. +. Q AGGREGATOR SPECIFICATIONS. ' 'r (Q -TERM -10) Model number Q -BA -3-1 P-60 " Dimensions R 190 mm (W) x 227 mm (D)'x 80 mm (H) (7.5 in (W) x 9 in (D) x 3.2 in (H)) Enclosure r , to45° from horip z0;160:1 Temperature range . , :40* C to +55' C (-40° F to +122° F) , Compliance U1-1703; EN62109, UI -6703A. s +- 7, • Q CABLE SPECIFICATIONS "Voltage rating ,,600V (connector rating 250 Vj _ ,. Cable temperature rating 90° C (194-F) t . Certification. * •-UL3003, DG cable +' * ` Flame test rating ' FT4 Compliance }, RoHS; OIL RES 1, CE, UV resistant, combined ULfor Canada and United States . - Cable insulator rating t THHN/THWN-2 dry/wet Q CABLE TYPES / ORDERING OPTIONS Model Number 2 Max Nominal Voltage, Connector Spacing PV Module Orientation , Connector Count per Box " Q-12-19-240 0 _ ` 250 VAC r t 1.3 m (4:7 ft) Portrait 2'40. - Q-12-17-240 ' 250 VAC 2.0„m (6.5 ft) Landscape (60 -cell) 240 Q-12-20-200 - ;�. �` ”; , 250 VAC 2,3 m (7.5 ft) _ Landscape (72=6e11) 200. ENPHASE Q CABLE'ACCESSORIES Name `, Model Number Description Enphase Q Aggregator i, Q': BA -31 P-60 Combines up to three microinverter branches into one home run. 1 ^•Field-wireable connector (male) ... ' Q -CONN -10M Make connections from any Q Aggregator open connector Field-wireal le connector (female), R Q-CONN,IOF Make connections fromany Q Cable open connector Cable Clip ; 6-CLIP7100 Used to fasten cabling to the racking or to secure looped cabling • DisconnectT(701 „ t' Q -DISC 10 Disconnect tool for Q Cable connectors, DC connectors, and AC module mount ; Q Aggregator sealing caps (male) ',' 6 -BA -CAP -10 w Sealing cap for unused aggregator connections Q Cable sealing caps (female),. ° ° Q:SEAL 10 - One needed to cover each unused connector on the cabling Terminator Q -TERM -10 Terminator cap for unused cable ends Y Replacement DC Adaptor (MC4) 77=- -` DC adaptorto'MC4 (max voltage 100 VDC) 77 Replacement DC Adaptor (UTX)' Q=DCC-5 `' %DC adaptor to UTX (max voltage 100 VDC) " TERMINATOR. i'-� + { Terminator cap for unused cable ends, sold in packs of ten-,*- SEALING CAPS s Sealing caps for unused aggregator and cable connections (Q -TERM -10) (Q -BA -CAP -10 and Q -SEAL -10) ' _ DISCONNECT TOOL" Plan to use at least one per' ' installation, sold in packs of tens tom,.ti k .- CABLE CLIP Used to fasten cabling to the racking or to secure looped cabling, sold in (Q -DISC -10)". packs of ten (Q -CLIP -100) To learn more about Enphase offerings, visit enphase.com' ` + © 2017 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. • E N P H A S E." 4 2017-0405 n 0 111110 8 JF meoa"w •_ /"' - �.. 'yam `i ,•• �;'1r�1' ` 1: �� ,.t •'a- e �`"-�,.1 fir` �'r ``� r ./��... �.+ ,1J1 r f ,-, t '•' ^� "•-iii , r � t •�- fy`f `•�'I a. Y • �•.t -� ii .. ,, �, rK•3-v� .�� �♦4 ti.• ,�.. � .+3 ' �' 1'. •-•.��;�-- � {�,� I,r , �• + Jk` it .♦ ....�-�. !z_ �. ,:� v 0 See Below , 1 \, 1 I , 1 , I 0 a i i w�'1'9s•: t N jjt 1� Cylindrical ; ; 3 f Min. "� a concrete form 12-. - 1 f r ' .01 footing option � 111*. a 1- v 2 +. 'j Above Grade I Distance depends Assemble reusable grade stakes (ProSolar metal grade ' ' on tilt an - (see angle ctrt) stake kit.shown). Recommend 2 x 4 vertical support.' 42' „ 30 F_' � Use"1/2'•"drill bit and 9/16" -socket to attach grade stake kit`to 2" x 4". -Attach `1" x 4"'wooden horizontal O -- support using 3-1/2" (min.) C -clamps. Grade stake kit Dig footings. includes: 24" threaded metal stake, aluminum spacer Lateral footingsans listed on page 4(bottom).block, bolt and washer. P P 9 � ,. Front to rear footing spans listed in angle charts on { " page 4 (top). OPlace horizontal 1-1/2" schedule 40 galvanized water pipe with slip-on Hollaerider® Tees.'Adjust C -clamps as necessary to level pipe. 4 Measure vertical pipe lengths, allowing 2" (min.) from bottom of footing to avoid pipe contact with moisture. 0 Insert vertical pipes into tees and fasten lower tee set screw. Center pipes in footings by sliding left or right. M� See Below , 1 \, 1 I , 1 , I 0 a i i w�'1'9s•: t N jjt 1� Cylindrical ; ; 3 f Min. "� a concrete form 12-. - 1 f r ' .01 footing option � 111*. a 1- v 2 +. 'j Above Grade I Distance depends Assemble reusable grade stakes (ProSolar metal grade ' ' on tilt an - (see angle ctrt) stake kit.shown). Recommend 2 x 4 vertical support.' 42' „ 30 F_' � Use"1/2'•"drill bit and 9/16" -socket to attach grade stake kit`to 2" x 4". -Attach `1" x 4"'wooden horizontal O -- support using 3-1/2" (min.) C -clamps. Grade stake kit Dig footings. includes: 24" threaded metal stake, aluminum spacer Lateral footingsans listed on page 4(bottom).block, bolt and washer. P P 9 � ,. Front to rear footing spans listed in angle charts on { " page 4 (top). OPlace horizontal 1-1/2" schedule 40 galvanized water pipe with slip-on Hollaerider® Tees.'Adjust C -clamps as necessary to level pipe. 4 Measure vertical pipe lengths, allowing 2" (min.) from bottom of footing to avoid pipe contact with moisture. 0 Insert vertical pipes into tees and fasten lower tee set screw. Center pipes in footings by sliding left or right. y �~a 6 wRest -pre= slotted, raiVon top of horizontal pipes ' and insJiaO-bolt. Place ry Drop- N,Lo'cky upport-raid! �, .a. ,� insertinto"the;ra;ll and � align with U-6ol61­land ® Pre -Slotted tighten nuts. \%\- "1- GroundTrac® F Support Rail ti Optional Snow Load Enhancer T , iii y ,,�1 �' .. t � . —. ,..—.-�-.,,.. �` .�.,-_•-- f" I Pour or pump ' ` �\ mixed concrete Install at least one �� " '\ 11, ..� into footings rail every 10 for proper pipe spacing.00, 01 i ' 4 ti. 1 _ -- 9 Remove grade stakes. ' O Tighten all tee set screws . to 17 ft -lbs with torque -• _ wrench. Install remaining rails, evenly tightening �U-bolt nuts. } f } Pre -assemble clamping EZ rail ; hardware and install solar modules and EZ rail endcaps. endcap Install 1-1/2" plastic pipe . endcaps for schedule 40 pipe as necessary. 4 10 Completed installation. Array Footing 124" and 136" Rail Angle Distance 124" x 2-1/2" Support Rail 0' 84" Angle Chart 1 Supports up to (3) 39.5" Wide Modules i 50 84" 39.5" ,r ' Array Footing 164" x 3" 10° 83" 15° 81" 20° 79" 25° 76" 30° 73" M 124I----- Max ... fro mtop I-- --- 2_1�2 of footing I- ----- . • • - rf� �m\ 136" x 2=1/2" Support Rail3��- » Lw v 'r ; � i • K,01 Supports up to (4) 32 5" Wide Modules 73" --- 76" - - 79" - 81" ._.. 83" ._.. 84" — 84" - 42" 124" and 136" Rail —I 12" F— 164" Rail .q Angle Chart 124" x 2-1/2" Array Footing 164" x 3" 32.5" I Angle Distance —I 12" F— 164" Rail .q Angle Chart —,'164' 124" x 2-1/2" Array Footing 164" x 3" • �a ' Angle Distance *. 10' . 2_3 2.. • 0o 108„ 6' 6' 84" Front to back footing spacing `r 50 108" Pre -slotted rails at: 84" on Center r ^ `164" •100 106„ x 3" Support Rail , Supports up to (4)39.5" Wide Modules J' .15° 104" r 200 101" —,'164' 124" x 2-1/2" 136" x 2-1/2" 164" x 3" 39.5'-- 9.5' —,'164 3� ` 108' a -- -- 104" — - — 106" — -- 108" — —�- 108" — 164" Rail 60" IMax from top of footing GroundTrac@ Rail Sizes 124" x 2-1/2" 136" x 2-1/2" 164" x 3" Number of Modules (3) 39.5" wide modules (4) 32.5" wide modules (4) 39.5" wide modules Lateral footing span (max) . non -snow load 10' . 10' 8' Lateral footing span (max) 30 Ib/ft2 snowload 6' 6' Not snowload rated Front to back footing spacing +see Angle Chart See Angle Chart See Angle Chart Pre -slotted rails at: 84" on Center 84" on Center 108" on Center 200 �_`-g1^ a ' Photo murtesy: Accurate Air & Electric , Professional Solar Prod cts,(ProSolar) a 1551G. , 5. Rose Ave., Oxnard, CA 93033 ` • 805-486-4700 • www.prosolar.coin @Professional Solar Products; Inc July -2009. GroundTrac@ is a 'registered trademark and covered under pat:#6,360,491', professional SOLAR products" l I . No buss bar �. us ProSolaro RoofTrac® tareo ,Intertek. Bonding and Grounding Guide. 1.111.2703 (Patent Pending) ) Green lock washer indicates electrical bond r Assembled Self -bonding Mid Clamp With SS Bus Bar Self -bonding Mid Clamp Fastened on Rail (solar module not shown) IF Applies to GroundTrac® and SolarWedge® mounting systems which utilize the RoofTrac® iail/clamp design. For RoofTrac® Rail Bonding Splice • Drill 1/2" holes at bottom of rails with 1/2" 110 Irwin Unibit® using the.rail support as a hole location guide. Insert 5/16" bolt through support holes and hand thread into thread rail splice insert. Fasten to 15 ft -lbs. r For Bonding Module Frame and Clamps to Support Rail • Fasten pre -assembled mid -clamp assembly to module frame, to 15 ft -lbs. Module Frame Design: double wall, aluminum, 1.2"-2.0" tall, 0.059"-0.250" thickness, UL1703 or equivalent tested module. UL467 standard tested bonding equipment for use with Professional Solar Products (ProSolar®) support rail. Bonding of module to RoofTra& rail via ProSolar® rail channel nut using buss bar. Bonding of RoofTra& rail to RoofTra& rail via ProSolar® UL467 tested universal splice kit (splice insert and splice support). Grounding of RoofTra& rail via Ilsco SGB -4 rail lug. System to be grounded per National Electrical Code (NEC). See NEC and/or Authority Having Jurisdiction (AHJ) for grounding requirements prior to installation. See final run (racking to ground electrode) grounding equipment installation instructions for specific installation information. COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2015: All information contained in this manual is property of Professional Solar Products (PSP). TileTra& is a registered trademark for PSP and is covered under U.S. patent #5,746,029. RoofTra& and FastJack® are registered trademarks for PSP and are covered under U.S. patent #6,360,491. RoofTra& bonding designs patent pending. ProSolar® UL2703 Bonding and Class A Fire Rating Page 1 of 4 professional SOLAR ProSolaro RoofTraco . products Bonding and Grounding Guide . (Patent Pending) Can be placed ' under module to - hide connection if desired Basic Wiring Diagram rounding Connection ;O SGB -4 rail ground connection Grounding Lug Grounding Lug COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2015: All information contained in this manual is property of Professional Solar Products (PSP). TileTrac® is a registered trademark for PSP and is covered under, U.S. patent #5,746,029. RoofTrac® and FastJack® are registered trademarks for PSP and are covered under U.S. patent #6,360,491. RoofTrac® bonding designs patent pending. ProSolar@ UL2703 Bonding and Class Afire Rating. Page 2 of 4 1.0 Reference and Address Report Number 100779407LAX-003 -Original. Issued:, 147Se -2012 'Revised: 28 -Apr -2015 Standards) UL Subject 2703 - Outline of Investigation Rack Mounting Systems and Clamping Devices for Flat-Plate'Photovoltaic Modules and'Panels.'Issue #2: 2012/11/13 Applicant Professional Solar Products, Inc. - Manufacturer Professional Solar Products, Inc.. 1551 S. Rose Avenue 1551,VRosle Avenue Address r. Oxnard, CA 93033' '', r Address Oxnard,. CA 93033 Count USA ' , A Count USA Contact Stan Ullman a . ' Contact Stan Ullman Phone (805) 486-4700. t Phone (805) 486-4700 FAX (805) 486-4799 ` _ FAX (805) 486-4799 Email sCcr�.prosolar:com Email s@prosolar.com.- � -- '• ,- � .`�`�'s k.� � ,•�. '� yr y '• r _ . y ,. C 1 • 1 fir. � • V J�. • f .. f , • • � ,• 1 : - { Y a ,+� f•� '.' ,• A' .• - ••,f y - r •, r t '. 01 Page 1 of 63 This report is for the exclusive use -of 1ntertek;s;=Client and is provided' pursuant, to-ihe"agreement between Intertek and its .Client lnteriek's responsibility and liability'are limited to:the terms and -conditions Af the agreemeA Intertek,, assumes •no.liability.'to.any parfy,'othee than tothe Client in accordance'.witti the • # agrthen onry in its entirety: may' use'of the Interteok name o one of its marks forfthe salrt e;'or advertisem nt of h tt permit copying or distribution of, tt m report and ` . Ana tested material,`. product dr service must first be approved i writing by Intertek. The•observations-and'testresults"in this reportare(relevant only to the:sampletested. This report-byitselfdoes no[implythat the' - material, product; or service. is or has ever been underdh intertek certification program: • _ ProSolar® UL2703 Bonding and Class A Fire Rating' Page 3 of 4' 14, Report No. 100779407LAX-003- -Page 2 of 63 , `Professional Solar Products; Inc... ;• Issued:. 14 -Sep -2012 ' Revised: •28 -Apr -2015 2.0 Product Description Product Photovoltaic Racking System ; t Brand name' ProSolar _ The product covered by this listing report is a rack mounting system. It is designed to be installed on a roof. It will be secured by means of Fast Jack or Tile Trac attachments, i depending on'the type of roof it is intended to be installed upon. The Rooftrac mounting system is comprised of support rails and top-down clamping hardware. This device can be'used on most standard construction residential roof -tops: • - This system is in with the mounting, bonding and grounding portions of UL Subject -lowing 2703. This system has the fol fire class resistance ratings: Class A for Steep Slope Applications when using Type 1 or Type 2, Listed Photovoltaic' Modules. Class A for,Steep Slope Applications when using Type 2, Listed Photovoltaic Modules with or'without the wind skirt. Class A for Low Slope Applications when using Type 1, Listed Photovoltaic Modules when a minimum of 12" gap between the roof surface and the bottom of the module is mai ntained:;Class A for Low Slope Applications when'ussing Type 2, Listed ' Photovoltaic Modules when a minimum of 14" gap between the roof surface and the bottom of the module is maintained. ' RoofTrac has'different types of.bonding and grounding, below is a list of them: Bonding of module -to -Roof Trac rail via Weeb PMC Description Bonding of module-to-Rooffrac rail via Pro'Solar rail channel nut using buss bar_. Bonding of moduld'-G-Roof Trac rail via IlscoVSGB-4 lugs, Bonding of Roof Trac rail -to -Roof -Trac rail viaWeeb Bonding Jumper -6.7 Bonding of Roof Trac rail -to -Roof Trac rail via Ilsco SGB -4 Lugs Bonding of RoofTrac rail-to-RoofTrac rail via ProSolar UL 467 tested universal splice kit (Splice Insert and Splice Support) Issuance of this report is based -on testing to PV module frames with a height of 1 1/4 inch to 2 in lies The grounding of the entire system is intended to be in accordance with the latest edition of the National Electrical Code, including NEC 250:,Grounding and Bonding, and NEC 690: Solar Photovoltaic Systems. Any local electrical codes must be adhered in addition to the . national electrical codes. This product investigation was performed only with respect to specific properties, a limited range of hazards, or suitability for use under limited or, special conditions. The following - risks and other properties of this product have'not been evaluated: electric shock'Ultraviolet light exposure..' Models RoofTrac Model Similarity N/A 6 Fuse rating: 20 A Mechanical. Load: 30 PSF r Fire Class Resistance Rating: Ratings Class A for Steep Slope Applications when using Type 1 and Type 2,. Listed Photovoltaic Modules. s Class'A for Low Slope Applications when u'sirig Type 1 and Type 2, Listed Photovoltaic Modules. T. Mechanical load was tested using 60 Cell Canadian Solar Modules model CS6P with 40mm frame height and maximum span of 48 inches using 4 inch and 6 inch TileTrac or FastJack Other Ratings posts with 1-1/2 inch tall RoofTrac rail. And maximum span of 72 inches using 4 inch and 6 inch TileTrac or FastJack with 2-1/2 inch tall RoofTrac rail. ProSolar@ UL2763 Bonding and Class A Fire Rating » Page 4 of 4 , . ED 16.3.15 (Wan -13) Mandatory