Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B17-2826 024-010-087
BUTTE COUNTY DEPARTMENT OF DEIr'ELOPMENT SERVICES - INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) : 530 538.4365 (Cut off time for inspections is 3pm) Development Services cannot guarantee inspections on the date requested Office: 530.538.7601 Fax: `30.538.7785 www.ButteCountv.net/dds Permit No: B17-2826 Issued: 11/28/2017 APN: 024-010-087 Address: 292 E GRIDLEY RD, GRIDLEY Owner: PAWEK KARRIE A ETAL Permit Type: SOLAR ROOF -RES Description: SOLAR ROOF MNT (4.8 KW) AREA Flood Zone: SRA Area: SETBACKS for Zoning- AG_ SRA_ PW Front: Centerline of Road: Rear: SRA: Street: AG: Interior Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING Inspection Type IVR INSP DATE Setbacks 131 Foundations / Footings 111 Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Signed Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 Blockin /Unde inin 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed Shearwall/B.W.P.-Interior 134 Shearwall/B.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 417 Manometer Test Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed Permit Final 802 L&A7 Electrical Final 803 Mechanical Final 809 Plumbing Final 8,13 Fire Sprinkler Test or Final 702 Swimming Pools N Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Swimming Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 503 Pre -Plaster 507 Manufactured Homes Setbacks 131 Blockin /Unde inin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Skirting/Steps/Landings 610 Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: Length x Width: Insignia: FJ65-1 . Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final "PROJECT FINAL *Project Final is a Certificate of Occupancy for (Residenth 1 Only) PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION ELECTRICAL NOTES: GENERAL NOTES: JURISDICTION NOTES: LEGEND: This design complies with all applicable building codes and regulations CODE COMPLIANCE: Module including: 2016 CALIFORNIA BUILDING CODE Rail 2016 CALIFORNIA RESIDENTIAL CODE Stand-off O 2016 CALIFORNIA ELECTRIC CODE Rafter CEC 690.17 - Switch or Circuit Breaker. The disconnecting means for : 2016 CALIFORNIA FIRE CODE Breather Vent o ungrounded conductors shall consist of a manually operable switch (es) or 2014 NATIONAL ELECTRIC CODE , - ''� ° ' Other Vent ❑ O circuit breaker(s) complying with all of the following requirements: Chimney ❑ O (1) Located where readily accessible 1. THIS SYSTEM IS GRID-TIED VIA UL LISTED INVERTER (S). Skylight (2) Externally operable without exposing the operator to contact with live 2• ALL EQUIPMENT SHALL BE UL LISTED FOR ITS INTENDED s Surface-Mount Conduit , PURPOSE. Attic-run Conduit — — parts •3. THE MODULES AND RACKING SYSTEMS) ARE UL2703 AND UL Fence — — (3) Plainly indicating whether in the open or closed position 1703 LISTED WITH A CLASS A FIRE RATING. Shadow (4) Having an interrupting rating sufficient for the nominal circuit voltage Trees and the current that is available at the line terminals of the equipment. APN: 024010087 ' . Property Line OCCUPANCY GROUP GATEGORY: R-3 Revisions CEC 250.122 - Size of Equipment Grounding Conductors. Copper, CONSTRUCTION TYPE: V-B t Gate 0 DESIGN WIND SPEED: 110 MPH; CATEGORY C, RISK CATEGORY II t aluminum, or copper-clad aluminum equipment grounding conductors of the DESIGN GROUND SNOW LOAD: 0 PSF Detail Legend: wire type shall not be smaller than shown in Table 250.122 but shall not be EXTREME MINIMUM TEMPERATURE: -3'C X� Detail Revision A required to be larger than the circuit conductors supplyingthe a ui equipment. q 9 q P AVERAGE MAXIMUM TEMPERATURE: 48 'C XXX Drawing No. ID ELEVATION: 94 FT. VICINITY MAP: CEC 690.46(C) - Grounding for AC/DC Systems. - �'�"' _� CEC 690.14 (5) = Grouping. The photovoltaic system disconnecting means �"� 11 i•i. ' i• ..! ' ' shall be grouped with other disconnecting means for the system to comply with 690.14(C)(4). A Photovoltaic disconnecting means shall not be required PV01 COVER SHEET r u'• • �„'.� i ��* �• .'= at the photovoltaic module or array location. PV02 SITE PLAN PV02A ARRAY PLAN �,°•.•.•: _...., ..:.:j...•:.:;:� ::::: r:: L s r ^ u^:' ::... CEC 705.12(D)(2) - The output of utility interactive inverter shall be permitted PV03 ROOF PENETRATION LAYOUT PV04 ONE LINE DIAGRAMrF - j' ` rti Z•� �.� ti�ttss �' �• ^ v - "' ii.r:•...:,::» i%i' ::: to be connected to the load side of the service disconnecting means of the PV05 LABELS AND EQUIPMENT t t•• ��,:�- - "� � I• r:; j';�'�'�'".'^~ r. ` .: • other source(s) at any distribution equipment on the premises ... [provided PV06x DATASHEETS that the sum of the ampere ratings the overcurrent devices not l P 9 PV07x CALCULATIONS ; , . Sgt exceed 120% of the rating of the busbar or conductor. CEC 690.31(E)(1) - Wiring methods shall not be installed within 25 cm (10 y - " - ,; `.i+•`• AAA:::,JJJ r ' in.) of the roof decking or sheathing except where directly below the roof ► *,. surface covered by PV modules and associated equipment. Circuits shall be _ _ = µ c�c?..c:;:s: run perpendicular to the roof penetration point to supports a minimum of 25 -� .,�?x' ;;;;w�• •;•-- - cm (10 in.) below the roof decking. t -- ' ............ tl Microinverters with ungrounded DC inputs shall be installed in accordance SCOPE OF WORK: =:P t ; t •:::...--� with CEC 690.35. '. ;;;;...' 3F • ° • • • x � For ACM systems and Microinverters with ungrounded a DC input follow the THIS PROJECT ENTAILS THE INSTALLATION OF A'ROOF-TOP REVISION: DATE: DESIGNER: .DESCRIPTION: Electrician: 10-26-17 GW FOR PERMIT APPLICATION EGC requirements of (CEC 690.43). with CEC 690.35. PHOTOVOLTAIC SYSTEM. ` - Date: LICENSE THE POWER GENERATED BY THE PHOTOVOLTAIC MODULES As Shown: As Per Notes:❑ WILL BE GRID CONNECTED THROUGH APPLICABLE POWER Approved by 2)V CAM 1018035 DISTRIBUTION AND OVER CURRENT PROTECTION EQUIPMENT. V V V CLASS: C-10 Date 10-26-17 �CAPITALCITY y - SHEET TITLE : DRAWING SIZE: 11" X 17" CLIENT: KARRIE PAWEK PROJECT: GRID TYPE: COMPOSITION PANEL MODEL: HANWHA O. PEAK G4.1 300 MOUNTING TYPE: SNAPNRACK SERIES 100 DESIGNER: GENE WOO VfJ S O L A R COVER SHEET ADDRESS: 292 E GRIDLEY RD SYST. SIZE: 4.80kW-DC BLDG. STORIES: 2 PANEL QTY: 16 ROOF TRUSSESIRAFTERS 2X4 TRUSSES, 24" OC SALES ADVISOR: GRID 111 Derek PI CITY: GRIDLEY, CA 95948 UTILITY: PG&E AZIMUTH: 180,270,90* STRING/PANEL LAYOUT: STIR #1: 1 X 16 ARRAY ATTACHEMENTS: 24"-72" O.C. SITE SURVEYOR: LANCE DINGWALL Roseville, CA 95678 (916) 782-3333 CCL #1018035 PHONE: 530-713-9293 AHJ: BUTTE COUNTY PITCH: 18. 39° DATE: SHEET No. APPROX SQ. FT: 4100 INVERTER(S): www.capitalcitysolar.com (1) SOLAREDGE SE5000H-US (240V) SOLAR ARRAY DATA: 797LBS/288 SO FT REV 01 - 10-26-17, PV01 ROOF % USED BY SOLAR: 8 % OPTIMIZERS : (16) SOLAREDGE P320 POWER OPTIMIZER 2.77 LBS PER SO FT 111 Derek PI Roseville, CA 95678 (916)782-3333 CCL#1018035 www.capitalcitysolar.com PHONE: FRONT OF HOUSE PROJECT: GRID TYPE: SYST. SIZE: 4.80kW-DC BLDG. STORIES: UTILITY: PG&E AZIMUTH: AHJ: BUTTE COUNTY PITCH: APPROX SO. FT: ROOF % USED BY —UV 0 16' 32' 64' Scale: 1/32" = 1'-0" Electrician: Date: As Shown: O As Per Notes: ❑ Approved by )j I V 1/ Date 10-26-17 SHEET TITLE DRAWING SIZE: 11" X 17" COMPOSITION PANEL MODEL: HANWHA O.PEAK G4.1 300 MOUNTING TYPE: SNAPNRACK SERIES 100 DESIGNER: .GENE WOO SITE 2 PANEL QTY: 16 ROOF TRUSSESIRAFTERS 2X4 TRUSSES, 24" OC SALES ADVISOR: GRID PLAN 180,270,90* STRINGIPANEL LAYOUT: STR #1: 1 X 16 ARRAY ATTACHEMENTS: 24"-72" D.C. SITE SURVEYOR: LANCE DINGWALL 18. 39' DATE: SHEET No. 4100 INVERTER(S): (1) SOLAREDGE SE5000H-US (240V) SOLAR ARRAY DATA: 797LBS/288 SO FT REV 01 10-26-17 PV02 8% OPTIMIZER(S): (16) SOLAREDGE P320 POWER OPTIMIZER 1 2.77 LBS PER SO FT CITY djS0LAAR 111 Derek PI Roseville, CA 95678 (916) 782-3333 CCL #1018035 www.capitalcitysolar.com NOTES: STRINGING LEGEND: 1-1 - INV1-STRING1 1-2 - INV1-STRING2 FRONT OF HOUSE ' F kYY \ Y hk.Y ILL I \_ \_ DRIVEWAY j / 3' SETBACK i V k b i t V a h: V kk ME/ k > k k>i ikiT/M kk ks> Ykh Vi , ' kkki: kYYl khYY i> ii N) EXTERIOR EMT p'• f Cikf .• Yk N) SE5000H-US (240V) INVERTER WITH RGM ' kkkh „kii k=ik k f YY kiYf. i i; ik N) AC DISCONNECT �_�E) ROOF 1 El MAIN SERVICE PANEL METER# 1007460696 ' 0 5'-4" 10'-8" 21'-4" Scale: 3/32" = V-0" Electrician: Date: As Shown: C . - As Per Notes: Approved by Y Date 10-26-17 ' SHEET TITLE DRAWING SIZE: 11" X 17" ENT: KARRIE PAWEK PROJECT: GRID TYPE: COMPOSITION PANEL MODEL: HANWHA Q. PEAK G4.1 300 MOUNTING TYPE: SNAPNRACK SERIES 100 DESIGNER: GENE WOO ARRAY )REBS: 292 E GRIDLEY RD SYST. SIZE: 4.80kW-DC BLDG. STORIES: 2 PANEL QTY: 16 ROOF TRUSSESIRAFTERS 2X4 TRUSSES, 24" OC SALES ADVISOR: GRID PLAN GRIDLEY, CA 95948 UTILITY: PG&E AZIMUTH: 180, 270, 90• STRING/PANEL LAYOUT: STIR #1: 1 X 16 ARRAY ATTACHEMENTS: 24"-72"0.C. SITE SURVEYOR: LANCE DINGWALL )NE: 530-713-9293 AHJ: BUTTE COUNTY PITCH: 18.39' - DATE: SHEET No. ' APPROX SO. FT: 4100 INVERTERS : (1) SOLAREDGE SE5000H-US (240V) SOLAR ARRAY DATA: 797LBS/288 SO FT REV 01 10-26-17 * PV02A ROOF % USED BY SOLAR: 8% OPTIMIZER(S): (16) SOLAREDGE P320 POWER OPTIMIZER 2.77 LBS PER SQ FT ROOFING NOTE: SNAPNRACK SERIES 100 COMPOSITION ROOF ATTACHMENT ATTACHED WITH 5/16"x3.5" SS LAG SCREWS AT 72" MAX SPACING WITH MIN 2.5" EMBEDMENT INTO RAFTER. SNAPNRACK RAIL INSTALLED PERPENDICULAR TO 2X4 EXISTING ROOF FRAMING. 30 ROOF ATTACHMENTS TOTAL. q__ -zi -- f!1 S O L A R CLIENT: KARRIE PAWEK PROJECT: GRID TYPE: COMPOSITIC 111 Derek PI Roseville, CA 95678 (916)782-3333 CCL#1018035 www.capitalcitysolar.com ADDRESS: 292 E GRIDLEY RD SYST. SIZE: 4.80kW-DC BLDG. STORIES: 2 CITY: GRIDLEY, CA 95948 UTILITY: PG&E AZIMUTH: 180,270,90* PHONE: 530-713-9293 AHJ: BUTTE COUNTY PITCH: 18. 39° APPROX SO. FT: ROOF % USED BY SOLAR: 4100 8 .i PANEL OTY: STRING/PANEL PLAN VIEW, FLUSH MOUNT ON PITCHED ROOF Scale: 1R' = 1'-0' HANWHA O.PEAK G4.1 16 STR #1: 1 X 16 (1) SOLAREDGE SE500 (16) SOLAREDGE P320 MOUNTING TYPE: SNAPNRACK SERIES ROOF TRUSSES/RAFTERS 2X4 TRUSSES, 24" OC ARRAY ATTACHEMENTS: 24"-72' O.C. SOLAR ARRAY DATA: 797LBS/288 SO FT 2.77 LBS PER SO FT VV IvIUUULt SNAPNRACK RAIL SNAP 'N RACK FLASHED L -FOOT (E) COMPOSITION ROOF 5/16 x 3-1/2" SS LAG BOLT (E) BUILDING STRUCTURE D STANDOFF DETAIL Scale: 1 112'- 1'-0" —Y Y- 0 4' 8' 16' Scale: 1/8" = V-0" Electrician: Date: As Shown: ❑ As Per Notes: Approved by ',8 / 1V (/ Date 10-26-17 I SHEET TITLE E: 11' X 17• ROOF DESIGNER: GENE WOO PENETRATION SALES ADVISOR: GRID LAYOUT SITE SURVEYOR: LANCE DINGWALL DATE: SHEET N0. REV 01 10-26-17 PV03 / APPROX LENGTH: HO FT. / - APPROX LENGTH: 10 FT. r • UTILITY (E) MAIN SERVICE PANEL SQUARE D 200A RATED, 1PH, 3W, 120/240VAC1 METER (E) 200A MAIN BREAKER METER# 1007460696 101 CONDUIT AND CABLE SCHEDULE TAG CONDUCTOR COND. SIZE EGC SIZE NUM BER OF CONDUIT CONDUIT " TYPE CONDUCTORS TYPE SIZE - 1 PV WIRE #10 AWG #8 AWG (2), (1)GND N/A 2 THWN-2 #10 AWG #8 AWG (4),(1)GND EMT 3/4" NEC 705.12(D)(2) COMPLIANT 3 THWN-2 #10 AWG #8 AWG NOT USED EMT 3/4 MSP BUS RATING: 200A 120% OF BUS RATING: 240A 4 THWN-2 #10 AWG #8 AWG (3), (1)GIN D EMT 3/4" PV BACKFEED: 30A Text/Line Legend 5 THWN-2 #8 AWG #8 AWG NOT USED EMT 3/4" MAIN BREAKER: 200A [New� XISIng: Electrician: 6 THWN-2 #6 AWG #8 AWG NOT USED EMT 3/4" 30A+200A —240A : Date:— As Shown: ❑ 7' THWN-2 #14 AWG #14 AWG NOT USED EMT 1/2" As Per Notes: C] 8 THWN-2 #14 AWG #14 AWG NOT USED _ EMT 3/4" Approved by 9 THWN-2 #18 AWG #18 AWG NOT USED EMT 1/2" Date 10-26-17 41 'I" X 17" - SHEET TITLE CAPITALCITY DRAWING SIZE: 1 �!j S O L A R CLIENT: KARRIE PAWEK PROJECT: GRID TYPE: COMPOSITION PANEL MODEL: HANWHA O.PEAK G4.1 300 MOUNTING TYPE: SNAPNRACK SERIES 100 DESIGNER: GENE WOO ONE LINE ADDRESS: 292 E GRIDLEY RD SYST. SIZE: 4.8okW-OC BLDG. STORIES: 2 PANEL OTY: 16 ROOF TRUSSESIRAFTERS 2X4 TRUSSES, 24" OC SALES ADVISOR: GRID DIAGRAM 111 Derek PI CITY: GRIDLEY, CA 95948 UTILITY: PG&E AZIMUTH: 180,270,90' STRINGIPANEL LAYOUT: STR #1: 1 X 16 ARRAY ATTACHEMENTS: 24"-72" O.C. SITE SURVEYOR: LANCE DINGWALL Roseville, CA 95678 PHONE: 530-713-9293 AHJ: BUTTE COUNTY PITCH: 18. 39" - _ SHEET No. DATE: (916) .capital CCL lar.co#1018035 PER So. FT: 4100 INVERTER(S): (1) SOLAREDGE SE5000H-US (240V) SOLAR ARRAY DATA: 797LBS/288 SO FT REV 01 .10-26-17. PV04 www.capitalcitysolar.com �'� ROOF % USED BY SOLAR: 8 % OPTIMIZERS : (16) SOLAREDGE P320 POWER OPTIMIZER 2.77 LBS PER SO FT - SOLAREDGE ) 200A SE5000H-US (240V) HD WAVE 380V -480V DC SQUARE D 240 VAC DU221 RB J-BOX(S) '1 (RGM- SUNRUN) - 30A,240VAC LOCKABLE, (E) LOADS 1 STRING WITH P320 OPTIMIZERS (ROOF) ROOF #1,2,3,5 1 STRING(S) OF 16I • I InteDC1ed 2P, 30A Isc 15A / Voc 480 VDC Disconnect _____ Imp 12.63A / Vmp 380 VDC ________ __-- -------------�•--I ------------------------------ I��IZ7 GND ---•--- ---------------------------------- GND —f GND Bond racking with #8 bare Cu ' All Solar Equipment bonded to building Grounding System 101 CONDUIT AND CABLE SCHEDULE TAG CONDUCTOR COND. SIZE EGC SIZE NUM BER OF CONDUIT CONDUIT " TYPE CONDUCTORS TYPE SIZE - 1 PV WIRE #10 AWG #8 AWG (2), (1)GND N/A 2 THWN-2 #10 AWG #8 AWG (4),(1)GND EMT 3/4" NEC 705.12(D)(2) COMPLIANT 3 THWN-2 #10 AWG #8 AWG NOT USED EMT 3/4 MSP BUS RATING: 200A 120% OF BUS RATING: 240A 4 THWN-2 #10 AWG #8 AWG (3), (1)GIN D EMT 3/4" PV BACKFEED: 30A Text/Line Legend 5 THWN-2 #8 AWG #8 AWG NOT USED EMT 3/4" MAIN BREAKER: 200A [New� XISIng: Electrician: 6 THWN-2 #6 AWG #8 AWG NOT USED EMT 3/4" 30A+200A —240A : Date:— As Shown: ❑ 7' THWN-2 #14 AWG #14 AWG NOT USED EMT 1/2" As Per Notes: C] 8 THWN-2 #14 AWG #14 AWG NOT USED _ EMT 3/4" Approved by 9 THWN-2 #18 AWG #18 AWG NOT USED EMT 1/2" Date 10-26-17 41 'I" X 17" - SHEET TITLE CAPITALCITY DRAWING SIZE: 1 �!j S O L A R CLIENT: KARRIE PAWEK PROJECT: GRID TYPE: COMPOSITION PANEL MODEL: HANWHA O.PEAK G4.1 300 MOUNTING TYPE: SNAPNRACK SERIES 100 DESIGNER: GENE WOO ONE LINE ADDRESS: 292 E GRIDLEY RD SYST. SIZE: 4.8okW-OC BLDG. STORIES: 2 PANEL OTY: 16 ROOF TRUSSESIRAFTERS 2X4 TRUSSES, 24" OC SALES ADVISOR: GRID DIAGRAM 111 Derek PI CITY: GRIDLEY, CA 95948 UTILITY: PG&E AZIMUTH: 180,270,90' STRINGIPANEL LAYOUT: STR #1: 1 X 16 ARRAY ATTACHEMENTS: 24"-72" O.C. SITE SURVEYOR: LANCE DINGWALL Roseville, CA 95678 PHONE: 530-713-9293 AHJ: BUTTE COUNTY PITCH: 18. 39" - _ SHEET No. DATE: (916) .capital CCL lar.co#1018035 PER So. FT: 4100 INVERTER(S): (1) SOLAREDGE SE5000H-US (240V) SOLAR ARRAY DATA: 797LBS/288 SO FT REV 01 .10-26-17. PV04 www.capitalcitysolar.com �'� ROOF % USED BY SOLAR: 8 % OPTIMIZERS : (16) SOLAREDGE P320 POWER OPTIMIZER 2.77 LBS PER SO FT - LABELS Label to be installed at Main Service Panel per CEC 690.12 & 690.56(C) Label to be installed at inverter overcurrent device (s) per CEC 705.12(D)(7) EXTERIOR WALL Label to be installed at the point of interconnection per NEC 705.10 Label to be installed at Main Service Panel per NEC 690.15, NEC 690.13(B) Label to be installed at Main Service Panel per NEC 690.17(E) Label to be installed at the POI and all AC disconnects per CEC 690.54, CEC 705.10 CAUTION SOLAR CIRCUIT: Label to be installed on raceways , junction boxes, and conduit bodies per CEC 690.31 Label to be installed at Utility meter, Main service panel, & sub panel(s). NEC 690.64, NEC 705.12(D)(3) Label to be installed at Utility meter/Main service panel. NEC 690.15, NEC690.13(B) Label to be installed at the DC photovoltaic disconnect per CEC 690.14(c)(2) CEC 690.53 AALC�ITY 292 E 111 Derek PI Roseville, CA 95678 (916)782-3333 CCL#1018035 www.capitalcitysolar.com Label to be installed at the DC photovoltaic disconnects per CEC 690.35 RD AHJ: IBUTTE COUNTY Label to be installed at the inverter(s) per CEC 690.5(c) NOTES: THE MATERIALS USED FOR MARKING SHALL BE REFLECTIVE, WEATHER RESISTANT AND SUITABLE FOR THE ENVIRONMENT. MARKING AS REQUIRED IN SECTIONS R331.2.2 THROUGH R331.2.4 SHALL HAVE ALL LETTERS CAPITALIZED WITH A MINIMUM HEIGHT OF 3/8 INCH (9.5mm) WHITE ON RED BACKGROUND. MARKING SHALL BE PLACED ON THE INTERIOR AND EXTERIOR EC CONDUIT, RACEWAYS, ENCLOSURES AND CABLE ASSEMBLIES EVERY 10' (3048mm), WITHIN 1 FOOT (305mm) OF.TURNS OR BENDS AND WITHIN 1 FOOT (305mm) ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES,WALLS OR BARRIEERS. TYPE: COMPOSITION PANEL BLDG. STORIES: 2 PANEL AZIMUTH: 180,270,90- STRIN( PITCH: 18.39° ROOF % USED BY SOLAR:1 8% 10 BOS EQUIPMENT IMfr. IModel No. IDescription IQty I HANWHA O.PEAK G4.1 16 LAYOUT: I STR #1: 1 X 16 SOLAREDGE P320 POWER OPTIMIZER MOUNTING TYPE: SNAPNRACK SERIES ROOF TRUSSESIRAFTERS 2X4 TRUSSES, 24" OC ARRAY ATTACHEMENTS: 24"-72" O.C. SOLAR ARRAY DATA: 797LBS/288 SO FT 2.77 LBS PER SO FT Electrician: Date: As Shown: As Per Notes: Approved by Date 10-26-17 SHEET TIRE Job -site Sign 1 lea. Hanwha Q. PEAK G4.1300 HANWHA Q CELL 30OW 16 ea. Solaredge SE5000H-US (240) SCALREDGE 5000W INVERTER WITH RGM 1 ea. SOlaredge P320 P320 Power optimizer 16 PV05 Square D DU221NRB 2P, 30A, 240VAC 1 ea. B -Line 011 125A, 1ph, 4 -jaw, NEMA 311 meter socket 1 ea. Square D QC) 230 2P, 30A BREAKER 1 ea. SnapNRack Series 100 Comp SnapNRack -Series 100 Composition Roof Mount 40 5/16"x31/2" SS lag bolt w/ sealing washer 40 ea. Buchanan 2006/2007 Cap Splice connectors 18-IOAWG with cap insulators Buchanan 2011/2014 Cap Splice connectors 14-4AWG with cap insulators C -TAP for irreversible gnd splice 6-12AWG 1 ea. C -TAP for irreversible gnd splice 4-12AWG 5 ea. Cone type 3/4-1" comp roof flashing with collar 1 ea. Zip ties 14" BLK Wire Clip HANWHA O.PEAK G4.1 16 LAYOUT: I STR #1: 1 X 16 SOLAREDGE P320 POWER OPTIMIZER MOUNTING TYPE: SNAPNRACK SERIES ROOF TRUSSESIRAFTERS 2X4 TRUSSES, 24" OC ARRAY ATTACHEMENTS: 24"-72" O.C. SOLAR ARRAY DATA: 797LBS/288 SO FT 2.77 LBS PER SO FT Electrician: Date: As Shown: As Per Notes: Approved by Date 10-26-17 SHEET TIRE DRAWING SIZE: 11" X 17' DESIGNER: GENE WOO LABELS/ SALES ADVISOR: GRID EQUIPMENT SITE SURVEYOR: LANCE DINGWALL DATE: SHEET N0. REV 01 10-26-17 PV05 A ° - , - � ' � � .' �. : `• s .powered by - • r SPECIFICATION -' .. • "� * ' "- _(1670mm -' •, • .. -^ format 65 7 in x 39.4in x 1.26in (including flame) "°I-----=---- x 1000mm x 32mm) _ i i - -- a _._____......_� �,.,..,._.-_..... �.. �.-._.•,... 'i'e.......w-.°mw.�i c 41.45lbS w • - ... '-,~Weigh i (18.8kg) a I -' " :r _. , c-i. f From Cover 0.13 in (3.2 mm) thermally late-stressed glass with anti-reflection technology - •,-•^"'� A _ r Cover Composite him -' '• - _ Back Co... .u..n _..:_..,_...,.4j:Y.C..... '�' . - ' {r�.a..s•••_-r,w-+•.,f r-❑ Frame Black anodised aluminum - °a• • x� s r/� _ • _�� w r - _ •_ _ _ _, a Cell r 6 x 10 monocryslalhne O.ANTUM solar Cells TM `� � a �.+ . , - a y • 1 n Junction box 2.60-3.031 x 4.37-3.54 in x 0.59 0 75m r - -, :. ,- •' (66-77 mm x 111-90mm x 15-19 mm) Protection class IP67, with bypass diodes- c ,. .- .. .._.. _....._. .�.�..4 mm __ Cable 4 mm= Solar cable; (+) 439.37 in (1000mm): (•) a39.37in (1000mm) � �• waw -� c ' Cannenor -Multi-Contact MC4 or MC4 intermateable. IP68 ' ' ELECTRICAL CHARACTERISTICS 1, t}_ - _ i {POWER CLASS - � .. 300 _ 305 ]. • . a - - '• MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC' (POWER TOLERANCE +5 W / ;0 W) _.. _ i- ' _• r^ T . Power at MPP' q P,,,, twl 300~ 305 y - ` E Short Circuit Current Iu [A] 9.779.84 t Open Circuit Voltage, Vw -[V] - - r 39.76r - 40.05 i ' 1 • " _ I •+ - Curie• tit at MPP•. I,r, [A] 9.26 9.35 .... ,___ ... _"- • _ _ •..a,•^r-'"-.__.__ 32.62 k Voltage at MPP*, V. [Vl......_,.,..•_....,^..._�.,...,,.-,...f.;�._._. 32.41 }, - e 4.1 is the ideal eapplications innovat solutionfor ciencyl -�� • . 218.0 218.3 all ha thanks to its innovative celltechnologyt chnology CI ANTUtM �.� MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NOCo%) : world-record cell design was developed to achieve the best performance �® -Pawa;atM?P "" -- P� " IWi -� '- `- 221.8 �' 225.5 under real conditions - even with low radiation intensity and on clear,® E' Shoff Circuit Current' IR fA] 7.88^- 7.94' a .19 Open Circuit Voltage* V. [V1 3737.46 +, ••. hot summer days. Current at MPP• - 1„n [A) - 7.27 - 7,35 -��-� • a • - j • 5 - LOW ELECTRICITY GENERATION COSTS Higher lower BOS thanks to - ® y ' • - • 'r -x' ` Voltage at MPP• - 30.49 - 30:67 V.M IV] v' ' a _ - -- --^ - -- - - - --- - - -- -- mow- -- ah-••-..-•---- Id0OW/n,r, 25"C, --an AM 1.5G ' Me-ament tolerances STC _3%; hot: c5% '60owfmr, NOCT, speevunn AM I.SG • ryp(ul raiup, acmel values may dr/ler �--»--*.- -� yield per surface area and costs - higher power classes and an efficiency rate of up to 18.6%. [EILLS PERFORMANCE WARRANTY -� - ] PERFORMANCE AT LOW IRRADIANCE --•- r----- �--- •� . + - , ; � • INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low-light + ® ®� _ �, _ � At IcaA 98% of nommai power during first year. Thereafter maw. 0.6% degradation per year. W w ""- .....-"-"-"..... At laws:92.6%af nominal power up to 10 years. At IeastA3.fis of nominal power up to 25 years. E im ' o , ` ..-AIL ' and temperature behavior. _ -terms - _ r?•A data within measurement tolerances. c n . _ _ .. ... .... .. .i Full warrant a in accordance with the warranty L - of the 0 CEL sales r LS organizslion of you espective country. m s• r r ENDURING HIGH PERFORMANCE * t Long-term yield security with Anti-PID Technology', ® ,wa r §' * MRAmAacuwmal 1! �, dl Hot-Spot-Protect and Traceable Quality Tra.OT^"" _ 2 ° a ie n a a Typical module Performance under low inadiance conditions in ��. ,,�. •w, ,,,, "A"x Icomparison tosTCconditions (25°C.IODOWlm' r'L• _ 1 ' EXTREME WEATHER RATING ,' High-tech aluminum alloy frame, Certified for high snow (5400 Pa) and wind loads (4000 Pa) regarding IEC. - QCELL$ _ T�PBRnrvD Pv TEMPERATURE COEFFICIENTS Temperature Coefficient of Iu * a _ 'I%/KI +0.04 Temperature Coefficient of V_Y I%/K] -0.28 $ - - -- ^^up ` Temperature Coefficient of P' � ~ Y .rrY_ [%/K) -0.39 Normal Operating Cell Temperature NDCT [°Fl 113 55.4 (45 t3°C)� PROPERTIESFOR SYSTEM DESIGN € `1 a Pf. ixxt 2 1 U ` ' = MAXIMUM COST REDUCTIONS _, ' Maximum System Voltage V,n: [V] 1000 (IEC) / 1000 (UL) Safety Class • J _ _ Maximum Series Fuse Rating IA OC] 20 }Fire Rating C (IEC) / TYPE 1 (UL) _ --_-- Y _ a • Up to 10% lower logistics costs due to higher module s • - capacity per box. - a , ;- _ + - -� Phnfnn. . -r Design load. push (UL)2 flbs/fl'] 75 (3600 Pa) Permitted module temperature -40°F up to+185°F du an continuous 40 °C up to+85°C) r _.--_�._•.. ._ _...._-....`._�_._�. �........___. ty.._ .._ �_ ,(- -1 OasiXn loatl, pull (UU' [lbs/N'] 55.6 (2666 Pa)Jr see installation manual- _ ____�._._._ ._ _ g _- .f V , A RELIABLE INVESTMENT CoantyTealod oceLLs Inclusive 12-year product warranty and 25-year lar mwaW p14 ,.,.war„ QUALIFICATIONS 1 CERTIFICATES PACKAGING INFORMATION linear performance guarantee=. - to. 40032587 - - n : ° .•' - UL 1703: VOE QualityTested; CE-compliant: Number of Modules per Pallet 32 5 ' IEC 61215(Ed.2); IEC 61730(Ed. 1) application class A - -- - - - - ! •_ ' .. . Number of Pallets per 53• Container' --,-T� .� 30 - '. .. • i - ' Number m Pallets Der 40• Contalner �- �-- y -26 • • . - i APT test conditions: Cel is at--1500V • 1 SA'a ------�---- .-.... �.._„___._.�.,.,_..,.,., _ d,",°-us Palter Dimensions (l x W x H) .: 68.7 in x 45.3 in x 46.1 in + ' T• • against grounded, with conductive me-' tal foil covered module surface, 25°C. - - (1745mm x 1150mm x 1170mm) e ' l ----+----,•-.-»-- -- W-.Lr-.----„w.._-_-----.-_ __- - - - , THE IDEAL SOLUTION FOR: t ; 168 It r r _ ' Pallet Weight 14351bs (651 kg)� 's y ' ` Rooftop arrays on ' ` • 7 - ® residential buildings + - ° See data sheet on rear for further r - information. - _ - NOTE: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use t - of this product.- [ Electrician: ' ,, - _ - _ . A, _ • - ' w Nanwha b CELLS America Inc. .. 4N r i. 300 Spectrum Center Drive, Suite 1250, Irvine, CA 92618. USA I TEL +1949 748 59 961 EMAIL mquiryeus.q.cells.com I WE wwwq-calls.us _ Date: • J L CE LLS x .. _ f - , "' As Shown- r ] Engineered in Germany y �` r a " 1 'As Per Notes: , A - (' - _ r Approved by " yif°*' . ..r° _ , } �- ` �• l I Y . _ s Date 10-26-17 .. f„• - .. . / -- - - •.,� ., • ., - - SHEET TITLE - r ' ..••CAPITALCITY - ,E' - • a - - - DRAWING SIZE: ' 11" X 17" CLIENT: KARRIE PAWEK PROJECT: GRID TYPE: COMPOSITION _ PANEL MODEL:' HANWHA O. PEAK G4.1 300 MOUNTING TYPE: SNAPNRACK SERIES 100 DESIGNER: _ _ GENE WOO VV I S O L A R DATASHEETS ADDRESS: 292 E GRIDLEY RD v SYST. SIZE: 4.80kW-DC _ BLDG. STORIES: 2 - PANEL CITY: = 16 - ROOF TRUSSESIRAFTERS 2X4 TRUSSES, 24" OC SALES ADVISOR: GRID 111 Derek PI - CITY: GRIDLEY, CA 95948 •- UTILITY: PG&E AZIMUTH: 180,270,90* STRING/PANEL LAYOUT: STIR #1:.l X 16 ARRAY ATTACHEMENTS: 24"-72" O.C. SITE SURVEYOR: LANCE DINGWALL . Roseville, CA 95678 (916) 782-3333 CCL #1018035 PHONE: 530-713-9293 - AHJ: BUTTE COUNTY PITCH: 18, 39° - - DATE: SHEET No. .. - ',t ' - _ - APPROX SO. FT: . ,; -.•'- ROOF -1. -USED BY SOLAR: 4100 8 % INVERTER(S): (1) SOLAREDGE SE5000H-US (240V) SOLAR ARRAY DATA: 797LBS/288 SO FT REV O1 •° OPTIMIZERS : (16) SOLAREDGE P320 POWER OPTIMIZER 2.77 LBS PER SO FT - _ www.capitalcitysolar.com - - 10-26-17 PV06 A ° • " Single Phase Invertersfor�North�Alllerica�-.. .- s dars� - - solar • • - SE3000H-US / SE3800H-US / SE5000H-US / SE6000H=US/ SE760OH-US SolarEdge Single Phase Inverters' - ` • SE3000H-US SE380OH-US, SESODOH-US SE6000H•US _ SE7600H-US 1 a � . O North A I a «_ OUTPUT - F 1 1 G I ere C Rated AC Power Output : :. 3000 3800 5000 6000 7600 VA , - -. - Max AC Power Output I 3000 I 3800 I 5000 I 6000 I-..--.•7600••,• I-•,-VA-...- SE3000H-US / SE380OH-US / SE5000H-US_ /.SE6000H-US / :Ac-ou.....tput V...... Min.-Nom.-Max.•.(1B3•• zos•. z?9),I .................. L........................ ...:..:. L...:.............:I......... :.........I,.•-yap..-- SE76OOH-US ACOutputVoltageMinNom Max (211 240 264) .... ........ ....... ... J ✓ ✓ J ,., ✓ .........I...............I:.. �........ I .. �... Vac• - , - AC Frequency (Nominal) - I 59.3 60. 60.5111 1 Hz , Maximum Continuous Output Current 208V - - 24 _ .................. A - Output Current 240V I Maximum............... ................. 12.5 I. 16 I 21 _ i ' •: '25 ; . I 32 - A G FDI Threshold 1 r A , •� • Utility Monitoring, Islanding Protection, i ................... ... ................. ................ ,..................i-........... - - _ Country Configurable Thresholds' Yes IINPUT i Maximum DC Power - 4650 5900 7750 9300 11800 W ° -. •. • Transformer-less, Un rounded 8 L................... Yes I.....:...... , _ - - 12'25 •, a ............:.................... Maximum Input Voltage 480... . ........ ......... .... Vdc.... -. �" •. .. '. - Y¢aB� a ............. Nominal DC Input Voltage..... .. .. .....I......... ................... ................... .....I.......... .... 400..... . I Vdc - •° ..,--.......I Maximum In put Current 208V p.......................................... i.................:. ................. .......380 ........... .I....... - 15.5 - •11 - I.........:......... I................... I................... I.....,.,.....-..... Adc I............ - " - - - _• o •, Maximum Input Current 240V ................................................. 8.5 10.5 I 13.5 I 16.5. I 20 ................. ............... .......... ..... .. ................ I Adc ....... ' -, _. • ,,: ;,� ,' Max. Input Short Circuit Current' .........................�........ 45 • ........... ................... ........Yes ....... ... ... .... .................. Adc.. . I.......... a.' • .. Reverse-Polarity Protection ............................................................................ i ..'• j s - • .. m'��:0• Ground-fault Isolation Detec on �' tl .. I -- ................... ................... ............. ... .......... I........ ` y • • 600kr: Sensitivit •• ••99.- ................ ............... :I -- _ Maximum Inverter Efficiency I' ..... .... ••99.2 .' ..99.. %• . • E .. - . - .. ..- k •� CEC Weighted Efficiency _. Nighttime Power Consumption ...................... ..I.. .................. .................. ................. ................... .......< 2.5 ...... ....... I„.„%.. I.. ...W.... . - �' y; �.n -'•'r. -"""•' ADDITIONAL FEATURES . • - - Su orted Communication Interfaces .. . ...pp,,,,,.-.-..•„.............. h rn i I I I r .................. R5485 Et a et, ZgBee (options ),•Cel u a (optional) - / ;, ' ”, w . 3 '.., • O' Revenue Grade Data: AN51 C12.20 ”' ................. Optionall'I . .... .... .................- L . I....... _. ... , Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect I STANDARD COMPLIANCE i ....................................................... UL1741, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 .................. ........... ...... ... ...... ... .. .. . ........ ..... .........:: •� `� _`tet_ Grid Connection Standards "., _ IEEE1547, Rule 211'1, Rule 14 (HI) o` , ......................................................... Emissions _ I ............... .................. .................. ................. ................. - FCC PartlSClassB� "I••••••- ,t - ' •' i INSTALLATION SPECIFICATIONS ' .......................................................... AC Output Conduit Size/ AWG Range 0.75-1” Conduit / 14-6 AWG ..... ................... ................... ................... ................... - r • - DC Input Conduit Slze / # of Strings / AWG Range I - 0:75-1" Conduit /1-2 strings/ 146 AWG- ........ + :, .. _ Dimensions wnh Safety Switch (HxWxD) I ............ .. •: • • 17 7 x 14 6 x 6 8 / 450 x 370 x 174 .... ...... .............. ................... ................. -, in / mm ' - WeightwithSafetySwitch' -•. I,••,,, ................. I•--lb/kg •• .. w• . - - ,. ................. Noise ........ ....................................I................... ••.•25.3/11.5-•.- - .................. .. ................... ... `.?....... ............... I•• dBA.... �• .. Cooling........................................:......I.................. NaturalConvection .�.................i... .............."". ........ ........... .. . .. ..... .... ............ ' -, OperadngTeTRIr tureRanQe.•.•••...-.•-_._.,•••..-I•-..,..•-...•,••••• ls!'•. - -13 to +140/.25to+601°1(-40'F/-40•Coptlonl,•..• •••• ,•• •• .. -- I 'F/'C --- « _ - Protection Rattn�•--, ., I• ... ........ .......................... .... .................. .. .. ... .. •. •. •...... ...... ................. • .'------NEMA-3R (it verter with Safety,Switch)-.----- I.-•.. ....... - .. - - r • w For other regional sotdngs please contact Solo rEdge support 14 • - • Revenue grade inverter PIN: SE.caH-USOOONK2 Pending tertihwtion - . s a .. Pwvcide�ranng from 50'C� "_ - Optimized•installation with HD-Wave technology cl-°0 version P/N: SE—H-US000NN109 "Specifically designed to work with power optimizers " Record-breaking efficiency Integrated Arc Fault protection and Rapid Shutdown for NEC 2014 and 2017, per article 690.11'and 690.12 • '. Extremely small ��� —, High reliability without any electrolytic capacitors 11111111111©�� , •Built-in module-level monitoring - - Outdoor and indoor installation wave a Electriciarr -,Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) - - " ,' Date: - sunsrc • _ RoHS A5 Shown: - _ As Per Notes:[_] - USA-CANADA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-UK-ISRAEL-TURKEY-SOUTH AFRICA-BULGARIA www.solaredge.US • • • ." .•, . • ' ,OPTIMIZED : • - r ((''�� A s/' I /f / Approved by J,b (/ I/ are tradernaiks or,eg:jstered trademarks of SolarEdge •. Technologies, Inc. All other trademarits inentioned herein • Date' „ 10=26-17 •c. - SHEET TITLE :�CAPITALCITY DRAWING SIZE: 11" X 17" CLIENT: KARRIE PAWEK PROJECT: GRID TYPE: ' COMPOSITION PANEL MODEL: HANWHA Q. PEAK G4.1 300 MOUNTING TYPE: SNAPNRACK SERIES 100 DESIGNER: GENE WOO Vll S O L A R DATASHEETS • ADDRESS: 292 E GRIDLEY RD SYST. SIZE: 4.80kW-DC BLDG. STORIES: 2 PANEL QTY: 16 ROOF TRUSSESIRAFTERS 2X4 TRUSSES, 24" OC SALES ADVISOR: GRID 111 Derek PI CITY: GRIDLEY, CA 95948 UTILITY: PG&E AZIMUTH: 180,270.90* STRINGIPANEL LAYOUT: STIR #1: 1 X 16 ARRAY ATTACHEMENTS: 24"-72" O.C. SITE SURVEYOR: LANCE DINGWALL Roseville, CA 95678 (916) 782-3333 CCL #1018035 PHONE: 530.713-9293 AHJ: BUTTE COUNTY PITCH: 18. 39• - DATE: . SHEET NO. . ,- t APPROX SQ. FT: 4100 INVERTERS : �• (1) SOLAREDGE SE5000H-US (240V) SOLAR ARRAY DATA: 797LBS/288 SQ FT REV 01 www.capitalcitysolar.com - = 10-26-17 PV06B ' ROOF % USED BY SOLAR: 8 % OPTIMIZERS : (16) SOLAREDGE P320 POWER OPTIMIZER 2.77 LBS PER SO FT - SD a r " • • . - $Q a r=qqSolarEdge Power Optimizer,:- ' r aj Module Add -On for North America -r.•. t' - . • , P300 / P320 / P400 / P405 - SolarEdgeTower Optimizer. ,, _ 3 J ' • "r•• P300 P320 P400 ' '.� - -Module Add For North America ' - - , (for 60 cell modules) (for high-power 60tell modules) (for 72 & 96 -cell modules) (for thin film modules) (, _ (INPUT {� • _ -On ; Rated Input DC Powerol 300 320 400 405 ......................:......................... ' W ... '' • P300 / P320 / P400 / P405 Absolute Maximum Input Voltage 48 80... ~ gid , '.I...;....... 125 (Voc at lowest temperature) '. - .....t.............................................:.......:......: ........ MPPTOperatingRa90-80..........L.....12.5, 105. .. , I....Vdc ' r .a - • c , ................I........................848........ ......`.........'.I .........8 ....... Maximum ShortCircuit Current (ISC) I ....... .10. .I 11.' I 10.1 ................. .. I Adc • y • ....... . .. .. ...... .. . ... ............ Maximum DClnputCurrent,....•.-- I:.......•••12:5 I..........13.75..........I.........••.••..•.......12.63"• ........... .. ... .. .. _ F Mawmum Efficient 99.5 Weighted Efficiency... I..................................................98:8...........................,'.................... ........ ....... I %...... r I.. II , Overvoltage Category I... I OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING sOLAREDGE INVERTER) Maximum Output Current 15 ........... .......................... .I........... ........................... ... ....... Maximum Output Voltage I 60 I 85 I Vdc " I OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) ..r. k . Safety Output Voltage per Power o. • Optimizer 1 Vdc •pawe7 b IISTANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 ................................................................................... - .. ... 0 2�JVears MattaS y Safety IEC62109-1 Iclass II safety), UL1741 ' ........................ ........... .... .................... i.. t:a".. - a • rl. .. yr+ 461 RoHS Yes I INSTALLATION SPECIFICATIONS ` Maximum Allowed System.V.oltage... ..................... ........ 1000. Vd.c.... f ' Com alibi e inverters p :.i .. ..... ...... ............:. .................. All SolarEdge Single Phase and Three Phase inverters ....lZ. .5 ............... ..I...........:. ....12. y: 4 Dimensions Dimensions (W x Lx H) w 12S 7.5 /.. i... $./.. x5.97x1. x5.97x13 x5.97x18 mm / in ' - 9..... 5x760 5' 37 S"1064 I e ......................:....:...... Wei ht Includin cables / 1.708 I / 2 3 I g r / Ib ¢ - .;„ ...(.........g.... Input Connector. ' - I Compatible I r ,• • ; . Output Wire Type /Connector ...................................`:I..:.......................................................................................::............:..I...... .........................................MC4 ........ ..............................: Double Insulated; MC4 Compatible ......... Output Wire Length......'...::::.......I ..............0,95 / 3:9...................... L..................... 1:2 / 3.9 . L. rn / ft § '. Operating Temperature Ranges...:.�....... ............ ................... 40-+85/-40-+185 .. .. Protection Ratin g......:.....:........-............................................................................... L IP68 / NEMA6P ....................... I ...:... =- Relative Humidity .................. ..... ....................... �:.100....................... :............... I...... 6 , .. . to Rated STC power of the module. Module of up to+5%power ........... tolerance allowed. , ._• - ' PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V -THREE PHASE 480V ASOLAREDGE INVERTEW) • ' + o ? Minimum String' Length g 10 18 " " •. . ,' ' ; - tY PV power optimization:at the: modulr e-leve�' x -k. (Power Optimizers) . .......................... ..............' ........ ...............50. Maximum String Length S _ r .. ; , .° I 25 25 I (Power Optimizers) - , — U to 25% more ener - ` .`. ' r' Y P' gY a .................................L....... 12750............ I Maximum Power er String 5250 6000 P I W v •. . — P R_ Y Superior efficient 99.5°� ff _ . ' w ', r.`. ................. ..............I Parallel Strings of Different Lengths Yes _ { —'Mitigates allh� es of module mismatch losses; fromrmanufactunn tolerance.to artial 'shading,r_ • 7 P g P k •r o. orientations .. '....:.........:........:........................................................................... • •"1 a 1%i - • .,. - - .' • __ it Is not allow¢d t° mix P405 with P300/P400/P600/P700 in one string.- — Flexible system design for maximum space utilization — Fast installation with a single bolt — Next generation maintenance with module -'level monitoring _ *, Electrician: Date: `" - __ —. Module -level voltage shutdown for insta_ ller and firefighter safety ' T f • - 4 - .. - aIKE 0% -' As Shown: .. As Per Notes:[_ - v USA- CANADA- GERMANY- ITALY•FRANCE-JAPAN-CHINA-AUSTRALIA THE NETHERLANDS- UK ISRAEL WWW,SOIaredge.u5 rr. . - Approved by • * Yy trademarks or registered trademarks of SolafEdge fechriologies. Inc. All other trademarks mentioned herein are JLJ ` , . 5 , r - , -are tre demarks of their respective owners. Date: 12/2015 ` Subject to change Mthout Date 10-26-17 SHEET TITLE r�CAPITALCITY a ' DRAWING SIZE: 11" X 17" CLIENT: KARRIE PAWEK / PROJECT: GRID TYPE: COMPOSITION PANEL MODEL: HANWHA Q. PEAK G4.1 300 MOUNTING TYPE: SNAPNRACK SERIES 100 DESIGNER: GENE WOO ;'11S O L A R DATASHEETS ADDRESS: 292 E GRIDLEY RD SYST. SIZE: 4.8Okw-DC BLDG. STORIES: 2 PANEL QTY: 16 ROOF TRUSSESIRAFTERs 2X4 TRUSSES, 24" OC SALES ADVISOR: GRID, ' 111 Derek PI CITY: GRIDLEY, CA 95948 UTILITY: PG&E AZIMUTH: 180,270,90- STRING/PANEL LAYOUT: STIR #11: 1 X 16 ARRAY ATTACHEMENTS: 24"-72" O.C. SITE SURVEYOR: LANCE DINGWALL Roseville, CA #101 (916) 782-3333 CCL #101 8035 PHONE: 530-7133 AHJ: BUTTE COUNTY -929 PITCH: - 18. 39` I DATE: , SHEET No. - - APPROX SQ. FT: 4100 INVERTER(S): - (1) SOLAREDGE SESOOOH-US (240V) SOLAR ARRAY DATA: 797LBS/288 SO FT REV 01 www.capitalcitysolar.com 10-26-17 PV06C ROOF %USED BY SOLAR: 8 % OPTIMIZERS : - (16) SOLAREDGE P320 POWER OPTIMIZER 2.77 LBS PER SQ FT c^ •n } 9 �" �'� 'rte" ` f-• r` ! f�.i _ . ;i _a ✓r. �� •5 "y - r • � � • • • • t� v" ^�"` + - F . + sok • ` p! ! _ �., ' Fltsh:::d L Fu ,; •Ct '=a s L Fh sit:'ti I...f='cnr Kit / s5t m :^d , s The SnapNrack line of solar•mountirig Flashed L Foot Kit Assembly Flashed L Foot Kit Dimensions ' - „ - '"',.•' '• � _ . systems is designed to reduce total r 5N PN K C-1. MOT _ - f �SMAP MCM l2 OEGSEE Li00T. CLEAS ORBUCK ! installation costs. The system features m,s,! rIASGE xur technical innovations proven on more. III"LOCK SPLLOCH WASHES than 300+MW of solar projects to simplify3»aPN1G. r .• installation and reduce costs. Flashed L Foot Simplified SnapNrack Series 100 Flashed L Foot Kit is an F innovative solution to provide a long lasting watertight ` , ^\��� / - j•- seal over the life of the system. The Flashed L Foot ' FldShed L Foot in 4 Simple Steps: provides a fully flashed roof fastener for attachment to 1) Locate a rafter in the roof using a pilot ,.,, - composition roof with no required cutting of shingles. drill .. !yp\--. SMAPMIUCS L FOOT SASE ......._._... .__.._i_ _ ? The L Foot is engineered for maximum adjustability for';. 2) Install base to the -roof on top of the r +' a clean level installation. composition shingle - t ,"3) Use a breaker bar.to separate the is Y ' 1",slotted bolt connection composition shingles above,the base, ' , ` f and install the flashing fi , • 1" spacers available for increased adjustability r 4) Attach the L foot on top and proceed with �• • Clear or Black anodized aluminum components . rail installation and leveling ` (both available with black flashing) - Place order withyourdistributor. Purchase' :I • No Cutting of.shingles material for asingle project ororder in bulk,,.' { . Materials " r'I Foot Technical Data Palotil Pending 6000 Series Aluminum L Foot & Base stainless Steel Hardware Galvanized Steel Flashing w/ black all weather coating Material Finish Clear and black anodized aluminum Weight 1.3 lbs Design Uplift Load 350 lbs Uplift - Design Ultimate Load , 1,000 lbs Uplift , Warranty - 10 Year material and worksmanship'S, - + for additional savings - - .: � �SnapNrack� : Electrician: , x. + " Solar Mounting Solutions Date , '•{r • - (877) 732-2860 www.SnapNrack.com • As Shown ❑ _, ., - ?' t `,t . i . As Per Notes: ❑ Patent Pending �'+ - - _ _ r•� G'nn[etl on .eL'ycleo Paper using ioy baeed inks.• , Approved by , Jn�",�/A'j ♦' , - - 2010 by SnapNra.^k PV Moun[Inp System -All nyht'S rF•>C: ved. Date ' . 10-26-17 SHEET TITLE ::��C.APITALCITY DRAWING SIZE: 11"X17" T CLIENT: KARRIE PAWEK PROJECT: GRID TYPE: COMPOSITION - PANEL MODEL: HANWHA O.PEAK G4.1 300 MOUNTING TYPE: - SNAPNRACK SERIES 100 DESIGNER: GENE WOO 'rll S O L A R DATASHEETS ' ADDRESS: 292 E GRIDLEY RD SYST. SIZE: 4.8OkW-DC - - BLDG. STORIES: _ 2 PANEL OTY: 16 ROOF TRUSSESIRAFTERS 2X4 TRUSSES, 24" OC SALES ADVISOR: GRID ' 111 Derek PI CITY: GRIDLEY, CA 95948 UTILITY: PG&E AZIMUTH: 180,270,90* - STRING/PANEL LAYOUT: STIR #1: 1 X 16 ARRAY ATTACHEMENTS: 24"42" O.C. SITE SURVEYOR: LANCE DINGWALL Roseville, CA 95678 PHONE: 530-713-9293 _ - AHJ: BUTTE COUNTY PITCH: 18.39• - DATE: r SHEET NO. (916)782-3333 CCL #1018035 www.capitalcitysolaccom APPROX SO. FT: 4100 INVERTERS : - (1) SOLAREDGE SESOOOH-US (240V) - SOLAR ARRAY DATA: 797LBS/288 SO FT REV 01 - 10-26-17 Pv06D - ' ROOF % USED BY SOLAR: 8 % - OPTIMIZER(S): (16) SOLAREDGE P320 POWER OPTIMIZER 2.77 LBS PER SO FT - A' 1. �, - - _ _ � _ t .. • - • - • , , r - 4 t Series 100: SnapN rack - Friday, January3l, 2014 SnapNrack ' Structural Report and Calculations PV Mounting Systems \ - SnapNracknr No r m a n PV Mounting Systems. 6063 Allov Rail Tables 775 Fiero Lane, Suite 200 � � - San Luis Obispo, CA 93401 0-30 ft. Roof Height' "Series 100 Roof Mount" Cover Letter , Sche-el To Whom It May, Concern, ° We have performed calculations for the 100 series roof mount PV system based on Structural the information provided by SnapNrack. Included with this letter are the report and calculations. We did the calculations in accordance with the 2012 IBC, ASCE 7-10, 2012 NDS, and guidelines stated in the Solar America Board for Codes and Standards. En g i n e e r Some e components the SnapNrack to were u t 0 of th omponen s to S p k test data used to determine the capacity and section properties of materials. We collected the test data using the sozz sunrise Blvd. procedures outlined in the 2012 BC Chapter 17. Fair Oaks, CA 95628 (916)536.9585 (916) 536-0260 (fax) We included the following types of load combinations and building parameters into our Calculations: - 1989-2013 24 years ojexceAence • ASCE 7-10 wind speeds from` 110 mph to 190 for B and C exposure{ categories . ; r ASCE 7-10 Seismic Design Category E _ _ • ASCE 7-10 Snow Loads up to 120 psf ground snow �y . „::' ,•�s • Buildings with mean roof heights up to 60 foot tilt angles /'roof pitches 0-30 ft. Roof Height'�y�++" .� from 0 degrees to 60 degrees." r • Norman Scheel, S.E. 1 , LEED AP BD+C FEED AP Homes - , The calculations have also been completed in accordance with the 2006 IBC, 2009 Fellow• -S CE IBC, and ASCE 7-05. To use the data contained in this packet for projects that are, • Fellow-ASCE E -roil: nortnQnsse.com being evaluated to the older ASCE 7-05 wind speeds,.refer to Appendix A for a - wind speed conversion chart. Find the ASCE 7-05 (BC 2006/2009) wind speed in Rob Coon the Chart in Appendix A, identify the comes ondin ASCE 7-10 BC 2012 wind - General Manager PP' P g .. ( ) ' E-mail• robcootiOnsse.com speed value, and proceed with using the charts contained in this packet with the, - ' Steve Smith P.E. adjusted wind speed value. Project Manager - E-mail: stevesmithrn�nsse.com 'ln our opinion, the mounting system, outlined by SnapNrack Series 100 PV_70, Mounting System Code Compliance Installation Manual, is acceptable and meets Steven Cooksey the loading requirements as stated above. See the report and calculations included CAD sayeveisor' with this .letter, for more information. ' _ 'E-mail: steve[a?nsse.com ' ' s.. If there are any further questions, please contact Norm Scheel. OQ�Of ESS/04 Jackie Winslow Office Manager �� J. $ Ay E-ttoil: jackionnsse.com Norman Scheel PE, SE _ ► LEED-AP BD+C; LEED-AP Homes m - ' Fellow SEAOC ¢ CCVV^^0. 2% m • Fellow A.S.0 - � � . 1 � • ` ' Electrician: s sJR(/I;TUaP� �P Date: r P CAL1As Shown: 0 ' As Per Notes:[-] + • JAN 3 2014 NSSi 5022 Sunrise Boulevard Pair Oaks CA 95628 (916) .536-9585 Rev. 1213 ]/2013 ,Page 6' Approved by r Date 10-26-17 , ��# - - DRAWING SIZE: 11" X 17 _ SHEET TITLE CAPITALCITY it S O L A R CLIENT: KARRIE PAWEK PROJECT: GRID TYPE: COMPOSITION PANEL MODEL: HANWHA Q.PEAK G4.1 300 MOUNTING TYPE: SNAPNRACK SERIES 100 DESIGNER: GENE WOO CALCULATIONS ADDRESS: 292 E GRIDLEY RD SYST. SIZE: 4.80kW-DC BLDG. STORIES: 2 PANEL QTY: 16 ROOF TRUSSESIRAFTERS 2X4 TRUSSES, 24" OC SALES ADVISOR: GRID 111 Derek PI CITY: GRIDLEY, CA 95948 - UTILITY: PG&E AZIMUTH: 180,270,90' STRING/PANEL LAYOUT: STR #1: 1 X 16 ARRAY ATTACHEMENTS: 24"-72" O.C. SITE SURVEYOR: LANCE DINGWALL Roseville, CA 95678 PHONE: 530-713-9293 AHJ: BUTTE COUNTY PITCH: 18. 39° - DATE: SHEET No. - (916) .capit33 CCL #1018lar.co 35 APPROX SQ. FT: 4100 INVERTERS : (1) SOLAREDGE SE5000H-US (240V) SOLAR ARRAY DATA: 797LBS/288 SQ FT REV O1 www.capitalcitysolar.com 10-26-17 PV07A ROOF % USED BY SOLAR: 8 % OPTIMIZER(S): (16) SOLAREDGE P320 POWER OPTIMIZER 2.77 LBS PER SQ FT t .: ,Table IA: Rail Spans (in) for Roof Slopes and Tilt Angles 0° to 19° 6063 Alloy - ---- --------- Wind `l Table 16: Rail Spans (in) for Roof Slopes and Tilt Angles 20° to 36' 6063 Alloy ----- -.------------ -------\\'ind Load --------.-- -------- Vull. 110 115 f 120 125 130 135 140 � 145 150 � 155 160 170 .IRO Load --- ----------------- � _18.4_ ---9.0 20.0_ 21.G 23.3 ` \'nit 32.8 _ lIU IIS I'_0 125 130 135 14U 145 150 155. ICU 170 180 19U ..4 9� -20.R 15.5 16.9 18.4 20.0 I 21.G 23.3 Z5.1 2ti.9 28.3 I 30.7 32.8 37.0 41.5 46? - Pv Ps 8 112 III I IU .IU9 IOS 107 105 1111 103 � 99 95 I R3 7R . 0 IS I S9 R9 � 39 S9 -10.7 -11.7 -12.7 -13.3 -149 -16.1 -17.3 -IR.G -19.9 -21.2 -?2.6 -25.5 -28.fi -31.9 "C 0'• 75 1 75 i 116 110 104 99 -- 9S 91 87 33 77� . 75 70 65 -62, fib Gl 10 -0 8 114 110 141 99 95 91 S7 S3 80 .( 77 75 70 65 62 0 20 IS 89 `75 S9 89 S9 89 S9. R7 33 SO i 77 75 70 65 62 70 30 ?3 51 15 79 75 ' 75 75 75 75 75 75 75 i0 65 G2 43 411 31 Gfi fin GC+ Gfi Gb bG Gfi � 6G 66 - 6G - 66 66 65 [ 62 � 50 39 fi0 60 GU fi0 60 v0 CO 60 GU GU I 60 GO 60 :I 60. a .c. GO' 4G 35 55 55 55 I 55 55 ,55 55 55 I 55 55 55 v55 55 70 54 SI 51 SI 51 51 51 51 51 51 51 51 51 51 y51 -80 62 aS 4R 4S 4S aR 48 4S qR aS 4S 4F 4R 4S 4R 100 77 a3 43 a3 a3 43 43 a3 a3 a3 a3 a3 43 a3 a3 120 92 40 : •a0 -;040 a0 aU a0 40 Oil a0 40 a0 a0 40 a0 `l Table 16: Rail Spans (in) for Roof Slopes and Tilt Angles 20° to 36' 6063 Alloy ----- -.------------ -------\\'ind Load --------.-- -------- Vull. 110 115 f 120 125 130 135 140 � 145 150 � 155 160 170 .IRO 190 15.5 � _18.4_ ---9.0 20.0_ 21.G 23.3 _ 25.1 r 26.9 _ _ 2_R.8 I _30.7 _ -1 32.8 _ 37.11 41.5_ - Pg Ps -7.0 _16.9 -7.G I -S.3 -9.7 -10.5 -11.3 I -12.1 -13.0 -13.R -1a.7 -Ifi.b -1R.7 -20.R c � 0 0 120 - 12U- 12U 120 12U 118 112 l�IOS 103 9Y 95 'S9 83 7S v IU 8 112 III I IU .IU9 IOS 107 105 1111 103 � 99 95 R9 R3 7R . 0 IS I S9 R9 � 39 S9 R9 89 SR S7 96 RS R3 7S � 3U 23 75 75 75 75 75 75 75 1 75 15 75 75 75 „ 74 73 � 40 31 GG GG G6 bG G6 GG GG -Gfi fib Gl Gb 66.-, 6b•_ GG . - 50 39 60 (+U M 60 GU C+0 60 GO ( C+0 60 GO 6l! GU !+0 � 6U � 60 46 I 55 55 p' S5 55 55 55 55 ) S5. 55 I SS 55 55 55 55 v 70 54 51 51 .I 51 51 51 SI 51- � 51 51 � 51 51 51 51 51 •- 80 • ti2 4S aS I: 48 43 aS aR aS a3 aS aR IUO 77 a3 43 I a3 a3 43 a3 a3 j 43 a3 f a3 43 a3' a3 a3 120 92 ' a0 a0 � ao a0 ' aU 40 ao I at! ao 1 40 ao a0 ml q0 Series 100 Configuration Tool Report SnapNrack- Solar Mounting Solutions Company Name: Capital City Solar System Style: Create Date: 2017-10-26T14:48:08-0700 Project Name: Pawek, Karrie - 16 0 Bill of Materials #85752 Edge Screen Trim?: PV Module Data: Tilt Up?: Contact SnapNrack Module brand: Hanwha O Cells Length: 65.7 inches Frame color: Black Model: O.PEAK-G4.1 300 Width: 39.4 inches Weight: 41.45 pounds Rated power @ STC: 300 W Depth: 1.26 inches 3 assistance In designing tilt Environmental Requirements: Rail Finish: Black Wind Speed Standard: IBC 2015 Topographic Condition: Standard Snow Load: 0 psf Rafter Spacing: 24 inches Wind Speed: 110 mph 0 - Sub -Array Sub -Array Modules 162" Rail Rail Splices Mid Clamps End Clamps Roof Attachments Maximum Rail Span System Style: 7 4 0 Roof Attachments: Flashed L Foot, Black Edge Screen Trim?: No Tilt Up?: Contact SnapNrack 2 Galvanized Flashing, Edge Screen Trim Size: - inches Technical Support for 4 Black L Foot 120 _ 3 assistance In designing tilt 2 Rail Finish: Black Microinverter Attachment Kits: Yes - up applicatiions. 120 4 Array Skirts)?: No 0 - End Clamp Type: Universal 6 120 Totals: 16 10 0 22 20 28 - DATE: Grounding Method: UL 2703 Listed SOLAR ARRAY DATA: 797LBS/288 SO FT REV 01 - 10-26-17 PV07B Sub -Array Summary: Sub -Array Sub -Array Modules 162" Rail Rail Splices Mid Clamps End Clamps Roof Attachments Maximum Rail Span 1 7 4 0 10 8 10 96 2 3 _ 2 — 0 4 4 6 120 _ 3 3 2 0 4 4 6 120 4 3 2 0 4 4 6 120 Totals: 16 10 0 22 20 28 - Total System Size: 4.80 kW System Weights and Square Footage Links to Relevant Information SnapNrack System Weight Total Module Weight 133.47 663.20 lbs lbs Engineering_Documents Installation Manuals Microinverter/Optimizer Weight 20.5 lbs System_Drawings Total System Weight 796.67 lbs Video Tutorials Array Square Footage 287.62 ft2 Distributors, Distributed Load 2.77 psf Warranty' SnapNrack PV Mounting System • www.snepnr2ck cum - +(877)732.2860 - 775 Fiero LN, Suite 200. San Luis Obispo, CA 93401 41 Electrician: :::CAPITALCITY As Shown: ❑. If I S O L A R As Per Notes:[] CLIENT: KARRIE PAWEK PROJECT: GRID ADDRESS: 292 E GRIDLEY RD SYST. SIZE: 4.8OkW- 111 Derek PI SHEET TITLE CITY: GRIDLEY, CA 95948 UTILITY: PG&E Roseville, CA 95678. MOUNTING TYPE: SNAPNRACK SERIES 100 PHONE: 530-713-9293 AHJ: BUTTE (916) 782-3333 CCL #1018035 LANCE DINGWALL DATE: www.capitalcitysolar.com SOLAR ARRAY DATA: 797LBS/288 SO FT REV 01 - 10-26-17 PV07B 1 of 6 TYPE: COMPOSITIC 0C BLDG. STORIES: 2 AZIMUTH: 180, 270, 90" COUNTY PITCH: 18.39° APPROX SO. FT: 4100 ROOF % USED BY SOLAR: 8 PANEL MODEL: I HANWHA O.PEAK G4.1 300 PANEL CITY: 116 STRINGIPANEL LAYOUT: I STR #1: 1 X 16 IOLAREDGE SE5000H-US (: SOLAREDGE P320 POWER • Electrician: Date: As Shown: ❑. As Per Notes:[] I V I/ Approved by 1h f Date 10-26-17 SHEET TITLE 11" X 17" CALCULATIONS MOUNTING TYPE: SNAPNRACK SERIES 100 GENE WOO ROOF TRUSSESIRAFTERS 2X4 TRUSSES, 24" OC MADVISOR: GRID ARRAY ATTACHEMENTS: 24"-72" O.C.. LANCE DINGWALL DATE: SHEET NO: SOLAR ARRAY DATA: 797LBS/288 SO FT REV 01 - 10-26-17 PV07B 2.77 LBS PER SO FT -