B17-2915 030-211-050
R` P ' BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) :530.538.4365 (Cut off time for inspections is 3pm) Development Services cannot guarantee inspections on the date requested Office: 530.538.7601 Fax: 530.538.7785 www.ButteCounty.net/dds Permit No: B17-2915 Issued: 12/7/2017 APN: 030-211-050 Address: 1781 OROVILLE DAM BLVD, OROVILLE Owner: COON MICHELLE Permit Type: SOLAR ROOF -RES Description: SOLAR ROOF MNT (11.59 KW) ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING AREA Flood Zone: SRA Area: SETBACKS for Zon*nfy, AG. SRA. PW Front: Centerline of Road: Rear: SRA: Street: AG: Interior Total Setback from Centerline of Road: Inspection Type IVR INSP DATE Setbacks 131 Foundations / Footings 111 Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Do Not Pour Concrete Until Above are Signed Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 Do Not Install Floor Sheathing or Slab Until Above Signed ShearwalUB.W.P.-Interior 134 ShearwalUB.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 ' Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Swimming Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 1 503 Pre -Plaster 507OPy'. OFFICEC°0r-x:�,»�..�I tc+i ► 'ai 1 -' f - s' i M iBIdg Permit'' l7-"Z�IIS"'"'," "..:""' •"�-� Address: M XG•. S2BI;.� Date iL"F; _t4 } Electnc By. � Date: Y1 77 Skirting/Steps/Landings 610 Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: h Serial Numbers: Shower Pan/Tub Test 408 j Length x Width: Do Not Insulate Until Above Signed Insignia: Finals. Permit Final 802 Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test or Final 702 i' Public Works Final 538.7681 Fire De artment/CDF 538.6226 -Env. Health Final 538.7281 Sewer District Final **PROJECT FINAL *Project Final is a Certificate of Occupancy for (Residential Ooly) PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF 13SUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR RENEWAL 30 DAYS'PRIOR TO EXPIRATION i �Z�urrF, Butte County Department of Development Services T PERMIT CENTER y' 7 County Center Drive, Oroville, CA 95965 . Ou pT; Main Phone (530) 538-7501 Fax (530) 538-778 www.buttecounty.net/dds FORM NO `IDBI-01 Declaration of Installation } w: for Smoke Alarms and Carbon Monoxide Alarms The newly adopted 2013 California Residential Code requires the installation of Carbon Monoxide Detectors in dwelling units and in sleeping units within which. fuel -burning appliances', are installed and in dwelling units that have attached garages. The policy for Carbon Monoxide Alarms in Butte County states: "Any permit obtained in which the value of work exceeds $1000 associated with a Residential Group R Dwelling Unit or Sleeping Unit shall conform to the following 2013 California Residential Code requirements for Smoke and Carbon Monoxide Alarms (Section. R314 & R315).- 2013 California Residential Code requirements for Carbon Monoxide Alarms: R315.1 New construction: An approved carbon monoxide alarm shall be installed in dwelling units and in sleeping units within which fuel -burning appliances are installed and in dwelling . units that have attached garages. R315.1.2 Power supply: For new construction required carbon monoxide alarms shall receive their primary power from the Building wiring where such wiring is served from a commercial source and shall be equipped with a battery back-up. Alarm wiring shall be directly, connected to the permanent building wiring without a disconnecting switch other than as required for over - current protection. Exceptions: 1. In dwelling units where there is no commercial power supply the carbon monoxide alarm may be solely battery operated. 2. In existing dwelling units a carbon monoxide alarm is permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes . or there is no access by means of attic basement or crawl space R315.1.3 Interconnection. Where more than one carbon monoxide alarm is required to be installed within the dwelling unit or within a sleeping unit the alarm shall be interconnected in a manner that activation of one alarm shall -activate all of the alarms in the individual unit. 1 Exception: 1. Interconnection is not required in existing dwelling units where repairs do not result in the auas.c. ai iu i w wvvwus meinua ror Interconnection exlstea R315,2 Where required in existing dwellings: Where a permit is required for alterations, - repairs or add ition$3ezcbeding one thousand dollars ($1.,000),, e'xis'ting dwellings or sleeping units that have attached garages or fuel -burning appliances shall be.provided with a carbon monoxide alarm in•a`ccordance with Section R315.1. Carbon monoxide alarms shall only be' required in the specific•dwellirig unit or sleeping unit for which the permit was obtained. R315.2.6 Alarm requirements: No person shall install, market, distribute, offer for sale or sell any carbon monoxide device in the State of California unless the device and instructions have .been approved and listed by the State Fire Marshal. K: NEW_ WEBSIM3uilding�3uilding Forms & Documents\2014\2014 Forms - CompletedlDBI\DBi- 01_Declaration_for_Smoke_&_Carbon_Monoxide_Detectors—REV'D-8. 13.14_AKM.doc Page I of 2 ,, . r Carbon monoxide alarms required by Sections R315.1 and R315.2 shall be installed in the following locations: 1. Outside of each separate dwelling unit sleeping area in the` immediate vicinity of the bedroom(s). 2. On every level of a.dwelling unit including basements. R315.1.5 Multiple -purpose alarms: Carbon monoxide alarms combined.with smoke alarms shall comply with Section R315, all applicable standards, and requirements for listing and approval by the Office of the State Fire Marshal, for smoke alarm's. Butte'County's Interpretation of 2013 CRC, Sections `314 & 315 for Smoke Alarms & Carbon Monoxide Alarms: Where alterations, repairs or additions exceeding $1,000 in valuation, existing dwellings shall be retrofitted with smoke alarms and those that have attached garages or fuel -burning appliances shall have carbon monoxide alarms installed. Existing smoke alarms can be replaced with dual function alarms for Smoke and Carbon Monoxide and in most cases will comply with the aforementioned code requirements' `for Carbon Monoxide Alarms. DECLARATION OF INSTALLATION UNDER THE PENALTY OF.PERJURY As Owner/Contractor, I/we affirm and declare under the penalty of perjury, under the laws of the State of California, by our signatures below as Owner/Contractor, that.l/we will comply prior to final inspection with Items A & B as specified herein: A. Both Owner/Contractor have read and clearly understand the aforementioned 2010 California Residential Code (CRC) Carbon Monoxide Alarm requirements... B. Both Owner/Contractor are responsible for installing Carbon Monoxide Alarms prior to final inspection as per the aforementioned building code and maintaining such ' installation. Smoke Alarms will also be installed prior to final. inspection as per the 2010 CRC. Smoke and Carbon Monoxide alarms are now installed in, the following locations: / . re" DX t /-y ( A c A 3Ld,Gno .�•� ., _ / � .� /- A�GB�►J.ay A•yeC r— Owner's name (print): 'Zn ic-? LIl'' mos Owner's signature:: Date_7z/i Contractor's name (print): CSLB License: Contractor's signature: Date: Project Address: /78/ 640 [)/#1,., ,&Vc% ! Permit #: 9/7-Z5/s KANEW_WEBSIMBuilding\Building Forms & Documents\2014\2014 Forms - Completed0BRDBI- 01_Declaration for Smoke_&_Carbon_Monoxide_Detectors REV'D 8.13.14 AKM.doc Page 2 of 2 ABBREVIATIONS GENERAL NOTES ., A AMPERE �00� MOUNb �N01�OV0�1'�IC SY51M 1. THIS SYSTEM IS GRID -TIED WITH A UL LISTED INVERTER sunw.�=rigs 2. THIS SYSTEM HAS NO BATTERIES OR UPS 1010 WINDING CREEK WAY, STE. 100 AC ALTERNATING CURRENT ROSEVILLE, CA 95678 / ^ '/ _ 3. ALL WORK SHALL COMPLY WITH 2016 CBC (8ss)soo�soo 1 1 1' 9 r W PC info@sunC:441 90 CBC -CALIFORNIA BUILDING CODE j j I\ 4. ALL WORK SHALL COMPLY WITH 2016 CRC cAuc:aasso _ I NV LIC: 0079778 CEC CALIFORNIA ELECTRIC CODE 5. ALL WORK SHALL COMPLY WITH 2016 CEC CRC CALIFORNIA RESIDENTIAL CODE MICNFL`I � P055 6. ALL WORK SHALL COMPLY WITH 2016 CFC 7. ALL WORK SHALL COMPLY WITH 2016 CPC JOB NUMBER: CFC CALIFORNIA FIRE CODE 1 8. LOCAL UTILITY SHALL BE CONTACTED PRIOR TO ENERGIZING SYSTEM CH -4271 X81 0�0 bAM [3L Vn W 9. SMOKE/CO.DETECTORS ARE TO BE VERIFIED AT INSPECTION, PER CRC 314/315 DC DIRECT CURRENT o � I I I EGC EQUIPMENT GROUNDING 0p0VI��F, CA 9�9 5 - CONDUCTOR �J (E) EXISTING - Z. oz� VL5 Q_ EMT ELECTRICAL METALLIC TUBING w W w o GALV GALVANIZED - o z o # o Q m � o GEC GROUNDING ELECTRODE CONDUCTOR w GND GROUND J ELECTRICAL NOTES ADDITIONAL NOTES u; M z CURRENT 1. ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE REQUIRED U) U) uj Icont CONTINUOUS CURRENT 2. THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH THE CEC a g 2 OZ) - oo O Imp MAX POWER CURRENT 3. ALL CONDUITS CONTAINING PV CIRCUITS SHALL BE LABELED PER NEC 690.31(G) co ISC SHORT CIRCUIT CURRENT 4. BREAKERS SUITABLE FOR BACKFEEDING SHALL BE USED w w = I kVA KILOVOLT -AMPERE 5. MODULES AND RACKING SHALL BE ELECTRICALLY BONDED TOGETHER ACCORDING TO MANUFACTURER'S w L.L. INSTRUCTIONS, WHICH MAY INCLUDE INTEGRATED GROUNDING SYSTEMS FOR COMPONENTS APPROVED BY p = kW KILOWATT AN NRTL w LBW LOAD BEARING WALL 6. IRREVERSIBLE COMPRESSION/CRIMP SPLICES SHALL BE CONSIDERED CONTINUOUS. N Y g u Q MAX MAXIMUM 7. NO GEC IS REQUIRED FOR TRANSFORMERLESS INVERTERS, BOTH HOT CONDUCTORS ARE UNGROUNDED w Lo O j = 8. DC CONDUCTORS ENTERING THE BUILDING WILL BE RUN IN METALLIC RACEWAYS TO THE FIRST ACCESSIBLE N = =' cl MIN MINIMUM • MEANS OF DISCONNECT PER 690.31(G) N NEUTRAL 9. ALL METALLIC COMPONENTS SHALL BE GROUNDED WITH EGC w NEC NATIONAL ELECTRICAL CODE 10. A DC DISCONNECTING MEANS SHALL BE INSTALLED AT A READILY ACCESSIBLE LOCATION EITHER OUTSIDE OF 0 NRTL NATIONALLY RECOGNIZED THE BUILDING OR INSIDE NEAREST POINT OF ENTRANCE OF THE SYSTEM PV CONDUCTORS TESTING LABORATORY 11. BACKFEED BREAKER MUST BE LOCATED AT THE OPPOSITE END OF BREAKER OR LUGS PROVIDING POWER NTS NOT TO SCALE FROM THE UTILITY w r (N) NEW- OC EW-OC ON CENTER / 00 PL PROPERTY LINE f Rt o Lo O PTC PVUSA TEST CONDITIONS CRC FIRE SETBACK NOTES S•H EET INDEX � cD �- INSTALLED SYSTEM SHALL COMPLY WITH CALIFORNIA FIRE CODES BELOW J rn a v PV PHOTOVOLTAIC R324.7.1: ROOF ACCESS POINTS PV -1 COVER SHEET ((nco PVC POLYVINYL CHLORIDE ROOF ACCESS POINTS SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND0 Q LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING PV -2 SOLAR PLAN • p C U SCH SCHEDULE CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD PV -3 STRUCTURAL DETAILS J O J SS STAINLESS STEEL OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS J a J o R324.7.2: HIP ROOF PV -4 ELECTRICAL DIAGRAM w O W — o STC STANDARD TEST CONDITIONS ONE 3' CLEAR ACCESS PATHWAY FROM EAVE TO RIDGE MUST EXIST w 2 � ~ PV -5 ELECTRICAL CALCULATIONS w , a O TYP TYPICAL R324.7.3: SINGLE RIDGE ROOF ° U_ � op N z o TWO 3' CLEAR ACCESS PATHWAYS FROM EAVE TO RIDGE MUST EXIST PV -6 SIGNAGE SCHEDULE a O a o V VOLT R324.7.4: HIPS AND VALLEYS MODULE SPEC SHEETS COVER ONLY, PERMITTED TO BE ADJACENT TO HIP OR VALLEY. PV -7 Vmp MAX POWER VOLTAGE PANELS SHALL BE LOCATED A MINIMUM OF 18" FROM HIPS OR VALLEYS. WHEN ON ONE SIDE OF HIP OR VALLEY PV -7 INVERTER SPEC SHEETS PAGE R3 VOC OPEN CIRCUIT VOLTAGE 24.7.5: SMOKE VENTILATION PV -9 RACKING SPEC SHEETS W WATT PANELS SHALL BE LOCATED NO HIGHER THAN 3' BELOW RIDGE P\ /_ C/) D t. = m m �m OD ODz c o r D O c m z co cl) m D p cl) Zz .� c z' c SD T d 7 0 0 o• Zo0 CL m m m CL a CL T O .Z7 D� fn s m$ s m m w m m O 1mz m O %ai n D . - �, f' A 90 M`e m z m aWo a o D o m �+ o a a z C mx� z x N a 1 .Zm7 2 o m n Jz _ m O a c D 1c _ 0 N y m Z 0 0 z --I C L7 K 0 - m T a s -1 S o w 3 3 v o V% �� 0 00 rn - m Z O N T oo m. y s w m. 0 1 ' Vf D Z °o P» n>> c w rm Dm 00 c -u _ T 5; Ln m z A� z0 > D N W N V d ' r N 20 C. 1 W Om V io m r A nJi m tai. x N zz zSAN 0* c c >> c c N o CUSTOMER: SYSTEM SIZE: SURFACE TYPE: DESIGNER: MICHELLE DOSS 11.59 Kw COMP SHINGLE NTJK p 2 c 'o T v �J c w z o N o ADDRESS: INVERTER(S): DESIGNER SIGNATURE: m c —1 () 1781 ORO DAM BLVD W (1) SOLAREDGE SE7600H-US m C �`�� oCITY Oy o m mMODULES: STATE ZIP: c/) OROVILLE, CA 95965 # REVISION DATE g •. 0 ORIGINAL 117/2017 (38) HANWHA Q.PEAK DUO -G5 305 ° ° o ° 3* °o o d A MPU 1217-MLM APN: AHJ: UTILITY: HOA: B g < 3 m 030211050 CITY OF OROVILLE PG&E ---- m �N 0 D�, O EQUIPMENT SCHEDULE (E) ExISTING (N) NEW SETS DESCRIPTION E/N IDETAIL 1 1 PV STRING N 19 HANWHA Q.PEAK DUO -G5 305 MODULES . 119 SOLAREDGE P320 DC OPTIMIZERS 2 .1 4 PV STRING N 19 HANWHA Q.PEAK DUO -G5 305 MODULES 119 SOLAREDGE•P320 DC OPTIMIZERS 3 1 INVERTER- N ISOLAREDGE SE760OH-US 4 1 SOLAR BREAKER N 140A, 2P 5 1 MAIN PANEL N 1200A RATED 6 1 MAIN BREAKER N 200A 7 1 UTILITY METER E METER #: 1007637767 G z Y z Pv 1 STRING 0 CIRCUIT AND CONDUCTOR SCHEDULE r g J ' MP#: 1,3' Wire Size ; 1 SETS TYPE CONDUIT. PV + PV-, L1 L2 N I EGC/GEC A 2 ROOF PV DC FREE AIR 10 10 8 ` B - 2 PV DC 3/4" EMT 10 10 .8 C 1 AC 3/4" EMT 1 8 8 8 8 NOTES: 1. ROOF CONDUCTORS ARE PV WIRE AND BARE GROUND ' 2. ALL OTHER CONDUCTORS ARE THHN/THWN-2 UNLESS OTHERWISE SPECIFIED 3. SOLAR BACKFED BREAKER SHALL BE LOCATED FARTHEST FROM MAIN BREAKER 4. JUNCTION BOXES ARE NOT SHOWN BUT MAY BE USED FOR TRANSITION POINTS THROUGHOUT SYSTEM 5. MIN #8 AWG CONTINUOUS IRREVERSIBLE SPLICED WIRE FROM INVERTERS TO DEDICATED GROUND CLAMP TO SYSTEM GROUND ROD OR UFER. 6. SOLAREDGE INVERTERS ARE EQUIPPED WITH RAPID SHUTDOWN (NEC 690.12) sunW�r!�s 1010 WINDING CREEK WAY, STE. 100 ROSEVILLE, CA 95678 (866)600-6600 info@sunworksusa.com CA LIC: 441690 NV LIC: 0079778 JOB NUMBER: CH -4271 r g J G MP#: 1,3' G ; 1 Pv 1 1 STRING Pv O1 --11 OF - 19LAREDGE TSO! — L- z a OPTIMIZERS L._._._: 0 5"�iII ...... ...... --F------------- W -- —�� G IMP#: 2 G z Y z Pv 1 STRING Pv OF 19 II — SOLAREDGE =+ — L; 1 iRoQmUO OPTIMIZERS L.-._._._._._._._._. LU sunW�r!�s 1010 WINDING CREEK WAY, STE. 100 ROSEVILLE, CA 95678 (866)600-6600 info@sunworksusa.com CA LIC: 441690 NV LIC: 0079778 JOB NUMBER: CH -4271 r g J 0 N W z a 0 5"�iII W W �o z Y z O Z o iRoQmUO LU J c� Lo w Z M EL �: cz (� Lo 0 Q _ ° cr o U g o � Q w w o Ui 0 o Ui = U) 6 wLo �; < _ 0 ai r 10 M W 0 0 J CL N)200A 7 ' I METER J o o I > LL p Lo 0 w m rn a I I I Lu O LLI J �.w O J W j ul) o m = O V ya r rn 0 N � W co � O OQo ELECTRICAL - 1 UTILITY DIAGRAM PV -4 uc biae Module Specifications Hanwha Q.PEAK DUO -G5 305 P m p 305.00 W Vmp 32.30 Imp 9.44 A Voc 39.35 V Isc 9.93 A Voltage Temp Coeff. -110.18 mV/°C Ampacity Calculations Strine Values Solaredge uses optimizers and has fixed max voltage and operating voltage #in string 19 19 0 DC LABEL Imax P m p 5795 5795 0 11590 W Vmp 400 400 400 400 V Imp 14.49 14.49 0.00 20.00 A Voc 480 480 480 480 V Isc 15.00 15.00 0.00 30.00 A ABBREVIATIONS A CALLOUT B CALLOUT C ALTERNATING CURRENT 690.8(B)(1) 690.8(B)(2) Table 310.15(B)(3)(a) ASHRAE 2% High Table 310.15(B)(3)(c) Table 310.15(B)(2)(a) Table 310.15(B)(16) Table 310.15(B)(16) Imax 15.00 A 40.00 A Imax Icont 14.49 A 31.67 A Isc Conduit Fill Correction Imp MAX POWER POINT CURRENT V 4-6 conductors 0.80 1.00 Voc Temperature Correction 0 A 0 A 39.58 A Ambient Temperature 38 °C 38 °C A 0.5"-3.5" off roof 22 °C °C C7 to Effective Temperature 60 °C 38 °C I I 90°CTable 0.91 0.91 o Conductor Size L 2 PV circuit wire size 10 AWG 8 AWG J 75°C ampacity 35.00 A 50.00 A _ Greater than Icont? OK OK o 90°C ampacity 40.00 A 55.00 A U p Ampacity w/ Temp & Fill 29.12 A 50.05 A > Greater than Imax? OK OK ELECTRICAL ABBREVIATIONS A AMPERE AC ALTERNATING CURRENT DC DIRECT CURRENT I CURRENT Imax MAX PV CURRENT Icont CONTINUOUS PV CURRENT Isc SHORT CIRCUIT CURRENT Imp MAX POWER POINT CURRENT V VOLT Vmp 'MAX POWER VOLTAGE Voc OPEN CIRCUIT VOLTAGE AC Side InvPrtar cnPrifiratinns Load Center Connection Load Center Rating Inverter#1 Inverter#2 Inverter#3 Total 200TA SolarEdge SE760OH-US 40 A Max AC Power 7600 W 0 W 0 W 7600 W Max AC Current 31.67 A 0 A 0 A 31.67 A Max AC Current X 1.251 39.58 A 0 A 0 A 39.58 A Solar Breaker Size 40 A O A0 A 40 A Load Center Connection Load Center Rating 2001A Load Center 120% 240 A Main Breaker Rating 200TA Maximum Solar Feed 40 A Main Solar Breaker Size Main Solar Breaker size 40 A Breaker less than max feed?l OK SOLAREDGE NOTES 1. OPTIMIZERS REGULATE MODULE OUTPUT TO INVERTER 2. 'INVERTER INPUT VOLTAGE IS CONSTANT 3. INVERTER INPUT CURRENT IS CALCULATED WITH OHMS LAW WITH VOLTAGE CONSTANT AND POWER FROM THE ARRAY 4. INVERTER INPUT CURRENT MAX IS HELD AT 15A PER STRING BASED ON OPTIMIZER TOPOLOGY 5. OPTIMIZER OUTPUT CHARACTERISTICS ARE INDEPENDENT OF TEMPERATURE MAIN PANEL UPGRADE TO 200/200A END -FED MSP TO BE PERMITTED AND INSTALLED SEPARATELY BY A LICENSED ELECTRICIAN 705.10(D) (2) sunw, W% 1010 WINDING CREEK WAY, STE. 100 ROSEVILLE, CA 95678 (866) 60D-6800 info@sunworksusa.com CA LIC: 441690 NV LIC: 0079778 JOB NUMBER: CH -4271 J J r � O C ir w ~ Z J a. C7 to N W�� ter) I I I Uj W W W i x o L 2 J N N N J _ O > o Z o x o¢ m U p U-1 ti z N Z o > J O Ln ELECTRICAL z o Cl) a a CD � U <0 ; w LUX ; W C7 LU Q LU = N> ti Z U) y- 66 < _ waf � g ib r .�... 0 c w as c� CL PV -5 LU J J O ir U-) LL O 'I ter) a U - Um OQ 0) U 0 J N N N J _ O > � w O U it OO o ti z N Z o > ¢ O a o ELECTRICAL CALCULATIONS PV -5 �z r n - m m m G�� �z� �G�Z. �DO'.� mQ) GOo- �Z•� O (/)-�� n� 0°mo,n� v� O;n� r-zcD_U,D IT! ct)D rnD�ccl) �� � v� oz =� m -<z ��'mz mrcz moc z zn,=� z n•=� n��z zn�,• -�Z om��z m�, �oz eco E) ��G) �Dn Do�nZ O O�C�Z U) mc mmz oOzD � <-)z mzoN NZOD mr�,D mem n (m-) zoG?�D ���IIV O%OZZfv m m p Z m D O 0 m D m p m z� p z moo OC p0 ® o �• O = v � O X O X X m m 0 � • O � O p � D� n� X X =� ' • • vn D� -ri IT!OD n�icc(� • • • v �(n n� n n �mD =1m Q •• �ccn m0 -Z D z�n n<OOn • �.� z n n � Gf) (n 0 0 m D O • • • ,• � O O O O c z � m O O z .. • Z z Z m n I< m z IDS<.�<ID co m ;uz .a: ;. r.>r`Owm;�m ,3yT �cnDm�O�' (mnKrmm0�,. +• 1. t G)Z�. - • S " r7 l AD .A w' w ' LABEL NUMBER' SYSTEM SIZE: SURFACE TYPE: ti DESIGNER: c/) MICHELLE DOSS 11.59 KW x x DC COMBINER BOX. i .. " op p T V (� (n m z%H1 ADDRESS: r + ' ORO DAM W ., r INVERTER(S):, t DESIGNER SIGNATURE: x (1) SOLAREDGE SE7600H-US '<� DC ENCOLSURES ' - Q D CITY STATE ZIP: MODULES: - G7 • _ OROVILLE CA 95965 "' " _' p o ORIGINAL Wim20n r m M. " (38) HANWHA Q.PEAK DUO -G5 305 ' '` ' ' D ' A MPu r n x �2n-MLM. ,• x x 030211050 '; :`,' CITY OF OROVILLE,• PG&E g " x x DC DISCONNECT ____ m tON o D _ _ x RACEWAYS/CONDUIT m x x x_ x INVERTER ' AC DISCONNECT (IF PRESENT). x - SUB PANEL-_ r. D. x PRODUCTION'METER (IF PRESENT) o x ' = . MAIN SERVICE m. x x' POINTOF CONNECTION IDIDQ+ Q+ Q+ W Q+ Q+ IjDo V tel' o Q+ 0 Q+ LO Q+ W •• - - 0 0 0 0 0 0 Yn a o 0 N FWD W W 41 W N N Ln m G) co cop' p n T m o . Ln x n n n 0) O. Q+ O Q M 4_ 7, N w• UJ, m co m ;uz .a: ;. r.>r`Owm;�m ,3yT �cnDm�O�' (mnKrmm0�,. +• 1. t G)Z�. - • S " r7 l AD ' CUSTOMER: SYSTEM SIZE: SURFACE TYPE: ti DESIGNER: c/) MICHELLE DOSS 11.59 KW COMP,SHINGLE' NTJK p 2 z � A.CD .. " op p T V (� (n m z%H1 ADDRESS: r + ' ORO DAM W ., r INVERTER(S):, t DESIGNER SIGNATURE: BLVD (1) SOLAREDGE SE7600H-US '<� ' Q D CITY STATE ZIP: MODULES: - G7 • _ OROVILLE CA 95965 "' " _' # REVISION DATE o ORIGINAL Wim20n r m M. " (38) HANWHA Q.PEAK DUO -G5 305 ' '` ' ' D ' A MPu r APN: f AHJ: • UTILITY: • .JHOA: �2n-MLM. ,• 030211050 '; :`,' CITY OF OROVILLE,• PG&E g " 4 r ____ m tON o D _ _ powered It _, 0 1 The new Q.PEAK DUO -G5 solar module from Q CELLS impresses thanks to innovative Q.ANTUM DUO Technology, which enables particularly high performance on a small surface. Q.ANTUM's world -record -holding cell concept has now been combined with state-of-the-art circuitry half cells and a six-busbar design, thus achieving outstanding performance under real conditions - both with low -intensity solar radiation as well as on hot, clear summer days. 111111111111111111M��� Q.ANTUM TECHNOLOGY: LOW LEVELIZED COST OF ELECTRICITY Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 19.9°x. -- oitINNOVATIVE ALL-WEATHER TECHNOLOGY - Optimal yields, whatever the weather with excellent low -light and temperature behavior. rj ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID and Anti PID Technology', CaCELLS ' Hot -Spot Protect and Traceable Quality Tra.QTm: PPM A W , EXTREME WEATHER RATING . Format 66.3in x 39.4in x 1.26in (including frame) (1685 mm x 1000 mm x 32 mm) We)ght 41.21bs(18.7kg) -' Front Cover 0.13 in (3.2 mm) thermally pre -stressed glass with anti -reflection technology Back Cover Composite film Frame Black anodized aluminum ' Cell - 6 x 20 monocrystalline G.ANTUM solar half -cells _ - )unction box 2.76-3.35 in x 1.97-2.76 in x 0.51-0.83 in (70-85mm x 50-70mm x 13-21 mm), decentralized, IP67. - Cable 4MM2 Solar cable; (+)z43.3in It100mm),(-)243.3in(1100mm) - Connector Multi -Contact MC4,. IP65 and IP68 - -ii-�- �•I�T.r - surm rl.s 1010 WINDING CREEK WAY, STE. 100 - ROSEVILLE, CA 95678 . (866)600.6800 • info@sunworksusa.com CA LIC: 441690 • NV LIC: 0079778 JOB NUMBER: CH -4271 Lu J QCCIII Of N W POWER CLASS _ 305 310 315 320 325 330 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC' (POWER TOLERANCE +5W /-0W) - - - - - J ' Power at MPP° P_ [W] 305 _ 310 315 't 320 325 - 330 ShortCircuit Current* Ia [A] 9.93 9.98 10.04 10.09 10.14 10.20 E E Open Circuit Voltage., Va M 39.35 39.61 39.87 40.13 40.40 40.66 Current at MPP* I_ [A] 9.44 9.50 9.55 9.60 9.66 9.71 o Voltage at MPP* V_ M 32.30 32.64 32.98 33.32 33.65 33.98 I Efficiency2 n [%] 218.1 218.4 218.7 219.0 219.3 219.6 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NOC' ' W Power at MPP' P_ [w] 226.0 229.7 233.4 237.2 240.9 244.6 e Short Circuit CurrerR' 1. [A] 8.00 8.05 8.09. 8.14 8.18 8.22 Open Circuit Voltage* Vac M 36.80 37.05 37.30 37.54 37.79 38.04 Current at MPP' " I_ (A) 7.43 7.47 7.51 7.56 7.60 7.64 !Y Voltage at MPP* V,oe [V] 30.43 30.75 31.07 31.39 31.70 32.01 'LOOOW/rn2, 25•C, spectrum AM 1.5G-Measur_ttoler=!STCs3%;NGCs5% 'Soow/mr,NOCT•specWm AM1.5G �- 'typical values, actual values may differ - O CELLS PERFORMANCE WARRANTY t. PERFORMANCE AT LOW IRRADIANCE g_ At least 98%of nominal year. powdationn �10 '-r-----r----------i------ ;R i , J 06 ��dpom, u -°.a, m.r:,ev.,°.,,,me� Thereafter mac 0.54% degradation per year. per year. i At least 93.1%of nominal' power up to 10 years. At least 85% of nominal power up to 25 years. E - ' ' - - • ' • i r W All data within measurement tolerances. ' ---------- Full Full warranties in accordance with the warranty - • terms of the 0 CELLS sales organization of your ' ' f m 8 respective country. m - texAMUCE[W/m*I rEm Typical module performance under low irradiance conditions in L"PERATURE comparison to STC conditions(25°C, 1000W/mr) COEFFICIENTS v r� + _ '• Temperature Coe iiciem of Is • 01 ' [%/K] +0.04 Temperature Coefficient of V. - i 0 [%/K] - _0.28..' Temperature coefficient of Pm, y [%/Kl -0.37 Normal Operating Cell Temperature NOCT (°FI 113 t5.4 (45 t3°C) ' r Z Y LO U) - O Z❑ W Q 0CC Z t7 h Z 0 wFX�llf +1<1 Q Z ❑ m U❑ J iii Z OM �:U) c) U W.a r _ W O CD 0 n Uto o Q Qo I LLI W 3: i U) W UU Q UU = N .. Z Y w Q W rn !Y J 0 M W C ry J 06 d CL High-tech aluminum alloy frame,2017 certified for high snow f FOR DESIGN (5400 Pa) and wind loads (4000 Pa) regarding IEC. Maximum System Voltage Vs„ M 1000 (IEC) / 1000 (UL) safety Class II A RELIABLE INVESTMENT Maximum Series Fuse Rating [A DC] 20 Fire Rating " C (IEC) /TYPE 1 (UL) d W O pvma no Design load, push (LILY [IbsN!*1 - 75 (3600 Pal Permitted module temperature -40°F up to +185°F - J Inclusive 12 -year product warranty and25-year o�illtyre5ted �+I�a � on continuous duty (-40°C upto+85°C) r J • linear performance gUafantee2. Design load, pull (UL)2 nb3/R21 55.6 (2666 Pa) z see installation manual ^I O �.a•.v p'Innoat " STATE OF THE ART MODULE TECHNOLOGY ID. 40032587 ! f [ , , , ° > 0 Q.ANTUM DUO combines cutting edge cell separation UL 1703: VIDE Quality rested; CEtumphant-, Number of modules per Pallet _ _ 32 > � IEC 61215 (Ed.2); IEC 61730 (Ed.1) application class A O and innovative wiring with Q.ANTUM Technology. APT test conditions according to Number of Pallets per 53' Trailer _ 30 0 Lr) IEC/TS 62804-1:2015, Number of Pallets per 40' High Cube Container 26 method B (-1500 V, 168 h) DVE C E SA° s J _ Pallet Dimensions (l x W x H) 69.3 in x 45.3 in x 46.9 in m Lr) ¢ U z See data sheet on rear for further C mom' (1760mm x 1150mm x 1190mm) � _ THE IDEAL SOLUTION FOR: information. °""" C/) C - . _ Pallet Weight ' 1415lbs (642kg) " s _ O C rQ, ® Rooftop arrays on ® Rooftop arrays on • .- NOTE Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use y- Q Q U r residential buildi - of this product. dings commercial/industrial � LJJ � LLI buildings n HamTta 0 CELLS America lnc. - v O 300 Spectrum Center Drive, Suite 1250, Irvine, CA 92618, USA I TEL +190 748 59 96 1 EMAIL inquiry®us.4-cells.com I'WE9 www q-cells.us - J g Y OCELLS _ w --1 w _I o .Engineered in German 0 = 22 O a 0 o .V Q CO� Z o U O a o MODULE ' ` a SPEC SHEETS 0 "Solar Single Phase Inverters for North America Module Add -On for North America =gg SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US P300 - 'SE3000H-US SE380OH-US SE5000H-USSE6000H-US SE760OH-US .I IOUTPUT _ • 1 r ' I Rated AC Power Out ut 3000 3500 .5000 6000I7600 VA .Max, AC Power Output 3000: 3500 5000 60007600 VA AC Output Voltage Min.-Nom.-Max.(183 208 229) ✓ Vac AC Output Voltage Min.-Nom,.Max, (211- 240 - 264) ...... ✓ ✓ ✓ ✓✓ .................... .................... Vac AC frequency (Nominal) .................... .............................. 59.3 - 60 - 6..5 ) ............. Hz Maximum Continuous Ou[ ut Current 208V . _ 24 q Maximum Continuous Output Current 240V ' _ 12.5 16 21 25 32 .....................................�......... A GFDI Threshold _...............................................................................................Yes. ...I......... 1 _ A , Utility Monitoring, Islanding Protection, ............................................... Maxlmum DC Input Current Country Configurable Thresholds - Adc Maxlmum Efficiency iINPUT 1 ' Maximum DC Power ............................................................................................................................................................................. 4650 5900 7750 9300 11800 W . Transformer -less, Ungrounded .................................................................................... Yes ..'..................................................... I OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) ) Max! imum In ut Volta a 4..80 ......... Vdc Nominal DC In ut Volta a ..P......... �................. 380 t. 400 Vdc Maximum Input Current 208V 12) ................................................... .......................................... - - 13.5 `- - - ........................................ Adc Maximum Input Current 240V (2)1 ........... .......................... ........... .................... .................... 8.5 10.5 13.5 16.5 20 .... .... Adc Max. Input Short Circuit Current ....................I.................... 45 ............. Adc ......................................................................................................................................... - Reverse.PolarityProtection ..................................... ........... Ground -Fault )solation Detection ..............................ry............................................... ,Yes .............................. ...... .. 600koSensitivity .. .... - Maximum Inverter Efficiency : _ ......... ....................... 99 I . 99.2 ...................................................................................................... % CEC Weighted Efficiency ..................... ...... 99 ..................................................................................................................... ............. % Nighttime Power Consumption . < 2.5 W I ADDITIONAL FEATURES 128x152x27.5/ 128x152x35/ 128x152x50/ I Supported Communication Interfaces .... RS485: Etherne[f ZigBee (optional), Cellular (optional) ................................................. � (n .........................................................-F..- Revenue Grade Data ANSI C12.20 .Optionalla) ................................................................. ' Rapid Shutdown -NEC 2014 and 2017 690.12 r ' .Automatic Rapid Shutdown upon AC Grid Disconnect ' 1 STANDARD COMPLIANCE Double Insulated MC4 Compatible Safety .• ........................ .......................... UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 ..... ..... ..................................i m / ft Gnd Connection Standards ............................................................ IEEE1547, Rule 21, Rule 14 (HI) ....................................................................... , Emissions . FCC Part 15 Class B ` I INSTALLATION SPECIFICATIONS ' 0 - 100 ................................................................................................................... l AC qy!put.Co.nc1.u.it.Siz.e./ AWG Range 0.75-1" Conduit / 14-6 AWG = ; DC Input Conduit Size / # of Strings / AWG Range 0.75:1' Conduit /1-2 strings / 14-6 AWG .................................................................. 8 + 10 18 (Power Optimizers) ...........................................................................................................................:...................... Dimensions with Safety Switch (HxWxD) ...................................................................... 17.7 x 14.6 x 6.8 /45 0 x 370 x 174 1n / mm Weight with Safety Switch .................. 22 / 10 25.1 / 11.4 26.2 / 11.9 .................... ......... ............. Ib/k kg .... Noise ............................................................ `.25 <50 ................................................................ ......... . dBA..... ' Natural Q • convection and W ' Cooling Natural Convection internalfan (user ................................:........................... _ ................................................................................ re Iaceable Operat ng Temperature Range ........................ 13 to +140 / .25 to +600) (-40'F / •40'C option)is) ............................. ............................ F /'C ........ Protection Rating NEMA 313 (Inverter with Safety Switch) , • iii For other regional settings please contact SolarEdge support 2 A higher curcent source may be used; the inverter will limit its input current to the values stated p) Revenue grade Inverter P/N: 5E_H-US000NNC2 _ > Power de -rating from 50'C > U) • Isi 40 version P/N: SE-H-U5000NNU4 - W sun T ".ori<< •..•, vvv 1010 WINDING CREEK WAY, STE. 100 ROSEVILLE, CA 95678 (666)600.6800 info@sunworksusa.com CA LIC: 441690 NV LIC: 0079778 . t CH -4271 Solar =@@SolarEdge Power'Optimizer Module Add -On for North America P300 / P320 /T400,/ P405 ' P300 P320 P400 P40 5 • 1 r ' (for60.cellmodules) - (for high-power (fo r 72 & 96 -cell (for thin film QO 60 -cell modules) modules) modules) > {INPUT � Rated In ut DC Power p................"........... 300 320 400. 405 W ..............:...................................................................................................................... Absolute Maximum Input Voltage LL O ` (Voc at lowest tem eratureP. .........)...................... " 48 80 125- .............................................. ............................ ............ •............................. Vdc MPPT Operating Range .........................8. - 48 8: 80 - 105............ Vdc Maximum Short Circuit Current (Isc) ................................. . ..................12:5 .......... 10 11 10:1 Adc Maxlmum DC Input Current 12 5 13.75 12.63 Adc Maxlmum Efficiency ..................... Weighted Efficiency........................................................................... 98:g.........: ,. ........................................................... % Overvoltage Category II I OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) ) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc I OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) I Safety Output Voltage per Power r N N Optimizer 1 Vdc I STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6; 2, IEC61000.6-3 Q O Safety....... . ... ......... .............................IEC62109) (class ll safety) UL1741 ' W RoHS Yes I INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage Y............ ................ 1000.......................................................... Vdc..... Compatible inverters All SolarEd a Sin le Phase and Three Phase inverters co Dimensions (WxLxH) 128x152x27.5/ 128x152x35/ 128x152x50/ mm/in �, 5x5:97x1:08- 5x5.97x1.96 � (n Weilud ght (incin cables) ............, 760/1.7 830 / 1.8 . 1064 / 2.3 r Ib Input Connector MC4 Compatible Output Wire Type / Connector Double Insulated MC4 Compatible Output Wlre Length... 0:95 / 3 0 .......... .........:I........... .........1:?./3.9 .......................................... m / ft OperatingTemperatureRang?....................................................:40-+85/•-40:+185.............................". .................... �/. F.... ProtectionRatin&......................................................................IP68 / NEMA6P..:........................................................... Y Relative Humidity ....................... .............. ' 0 - 100 ................................................................................................................... '"Rated STC power of the module. Module ofup p to +5% power tolerance allowed. = ; PV SYSTEM DESIGN USING 8 SINGLE PHASE THREE PHASE 20V THREE PHASE 480V ASOLAREDGEINVERTEW) I Minimum String Length 8 + 10 18 (Power Optimizers) ...........................................................................................................................:...................... Maximum String Length 25 25 50 (Power Optimizers) ^ Maximum Power per String 52506000 12750 W ..................................................................................... . Parallel Strings of Different Lengths or OrientationsYes ......................................................................................................................................................... ❑1 It is not allowed to mix P405 with P300/P400/P600/P700 in one string. LrJ sun T ".ori<< •..•, vvv 1010 WINDING CREEK WAY, STE. 100 ROSEVILLE, CA 95678 (666)600.6800 info@sunworksusa.com CA LIC: 441690 NV LIC: 0079778 . t CH -4271 of • - '♦ t sun T ".ori<< •..•, vvv 1010 WINDING CREEK WAY, STE. 100 ROSEVILLE, CA 95678 (666)600.6800 info@sunworksusa.com CA LIC: 441690 NV LIC: 0079778 . t CH -4271 of W J J QO Q X > 2 O 'n p LL O N S uiS JLf) M l l a U w O � O 0 0 2 .W O W CZ7 i H � toW t%)O T- W r N N o of OC) 0 o Z LOU- Q r abo¢m-0 Q O INVERTER SPEC SHEETS ' W : J C7 Iii Z co LO � (n N Ur • O o p y U rD Y W W = ; _ CL W U' LrJ . Q W _ Y J ti w wW Q O 2 > j p CO > U) W 06 J /r\ b . 0_ W J J O X > O Lr) LL O JLf) M a U O CJI V 0 0 .W O W i H � W o 0 t%)O T- W r N N o of OC) 0 z o U C Q r U O Q O INVERTER SPEC SHEETS PV -8 • T - - Sna' O rack3Y Sia fV rackry • • ) Solar Mounting Solutions - Solar Mounting Solutions Series 100 Residential Roof Mount System- The ystem The SnapNrack Series 100 Roof Mount System is engineered to optimize material use, labor resources and aesthetic appeal. This innovative system simplifies the process of installing solar modules, shortens installation times, and lowers installation costs; maximizing productivity and profits. The Series 100 Roof Mount System boasts unique, pre -assembled, stainless steel "Snap - In" hardware and.watertight flash attachments, This system is installed with a single tool. No cutting or drilling means less rail waste. It is fully integrated with built-in wire management, solutions for all roof types, one -size -fits -all features, and can withstand extreme environmental conditions. Series 100 is listed to UL Standard 2703 for - Grounding/Bonding, Fire Classification and Mechanical Loading. UL 2703 Certification and Compliance ensures that SnapNrack installers can continue to provide the best in class installations in quality, safety and efficiency. • Appealing design with built-in aesthetics • No grounding lugs required for modules- • All bonding hardware is fully integrated - • Rail splices bond rails together, no rail jumpers required • No drilling of rail or reaching for other tools required • Class A Fire Rating for Type 1 and 2 modules Stainless Bolt withStainless Split -Lock Washer Steel Bolt with Split' Lock Washer _ Bonding Adjustable End Clamp Top Bonding Adjustable End Clamp Bottom _ Bonding able ; – Bonding Mld Clamp Bonding Channel Nu[ BBoondfng Mid Clamp End Clamp Clamp 24202061 , 242-02053 SERIES •• TECHNICAL Materials System Features Include - - - ;, , j��(�(� �. • �� r � Material Finish • �I .– Bonding Splice Standard Rail �–.`Insert 015-09816 - Splice J J Base 1� - Bonding O ' Stainless Hardware with Split -Lock Washers Channel Nut Stainless – Bolt with Split Lock % Washer % Bonding Standard Rail Splice 2425 01s LGr,Ound Lug –� .0210112-6 AWG Copper Wire t > Ground Lug Assembly (ONE REQUIRED PER ROW OF O MODULES) Universal End Clamp (UEC) wave -� UECPullStrap >(0 UEC Wedge L Stainless Steel Bolt with Flat Washer Universal End Clamp - 242-02ns . F e ` Serrated Stainless �� –Channel Channel Nut F Steel Flange Nut Nut Serrated Stainless – Steel Flange Bolt _ 92 Degree' L Foot Mill Finish L L Foot - L Foot Base fid"% Flashing L Foot Basew�Ith Flashing 242.92050 Stainless I Flange Nut yStainless Fl V ange Bolt All Purpose L Foot L Metal Roof Base Assembly Metal Roof Base with L Foot 242-0203) 6000 Series aluminum • Stainless steel • Galvanized steel and aluminum flashing • Silver and black anodized aluminum • Mill -finish on select products • Silver or black coated hardware Note: Appearance of mill finish products may vary and change over time. Snap In Single Tool Easy No Cutting Wind Loads 110 - 190 mph (ASCE 7-10) Hardware Installation Leveling. or Drilling - • Snow Loads 0 - 120 psf ' "0 ; �L Array Pitch 0 - 60 degrees 'Integrated Wire ' 9 s Preasdwar ed Integrated bonding UL 2703 Certified ' Management '-• hardware r � 877-732-2860 Resources snapnrack.com/resources 1 Design snapnrack.com/configurator 1. Where to Buy snapnrack.com/where-to-buy 1 www.snapnrack.com p contact@snapnrack.com ©2016 by SnapNrack Solar Mounting Solutions. All rights reserved snpn34ck5enas 100�Odue$.1• sunw.*3r!ts - 1010 WINDING CREEK WAY, STE. 100 ROSEVILLE, CA 95678 (866)600.6800 info@sunworksusa.com • CA LIC: 441690 NV LIC: 0079778 JOB NUMBER: . CH -4271 r � W 0 J ' o'eCIIIr W N rr aZ Q N sS2 W w I I I �o Z Y z 19 (9o Z o it OQm(J� W J to Z o CO to in W I Q g = X 0 C:) Q ai U r Y a I IJJ LU 0x i U) LL. W 0 0 Q LLJ _ N to Z W Y w p w Q rn _ U) � i. 0 . oo I — ? — � .Mi Lu oa •. J - rll RACKING SPEC SHEETS PV -9 ' W - J J j - O IX > O >(0 w m to ¢ U W 0') , U " J C) a w W O _J W ] 1.0 O i = h rn 00U)N q r` � Z O C5 :J G Q r' U O Q •O RACKING SPEC SHEETS PV -9