Loading...
HomeMy WebLinkAboutB17-2981 030-063-002Permit No: B 17-2981 APN: 030-063-002 BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES INSPECTION CARD IAUST BE ON JOB SITE 24 Hour Inspection Line (IVR) :530.538.4365 (Cut off time for inspections is 3pm) Development Services cannot guarantee inspections on the date requested Office: 530.538.7601 Fax: 530.538.7785 www.ButteCounty.net/dds Address: 1883 16TH ST, OROVILLE Owner: SPRADLIN THOMAS E & CHERYL J Permit Type: SOLAR ROOF -RES Description: SOLAR ROOF - RES (4.2KW) i SRA Area: Front: Centerline of Road: Rear: SRA: Street: AG: Interior Total Setback from Centerline of Road: AREA ALL PLAN REVISIONS MUST BE APPROV:'ZD BY THE COUNTY BEFORE PROCEEDING Inspection Type IVR INSP DATE Setbacks 131 Foundations / Footings 111 Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Signed Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 Blockin nde inin 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed Shearwall/B.W.P.-Interior 134 Shearwall/B.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 417 Manometer Test Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed Permit Final 802 Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test or Final 702 Swimming Pools tl Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Swimming Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 503 Pre -Plaster 507 Manufactured Homes Setbacks 131 Blockin nde inin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Under ound Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Ski rting/Steps/Land ins 610 o. Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: ` Length x Width: Insignia: I Public Works Final 538.7681 Fire De artment/CDF 538.6226 S Env. Health Final - 538.7281 ' Sewer District Final z "PROJECT FINAL A71 tl t *Project Final is a Certificate of Occupancy for (Residential Only) PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION i BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT 24 HOUR INSPECTION (IVR)#:530.538.4365 OFFICE #: 530.538.7601 FAX#:530.538.7785 www.BuUeCounty.net/dds '_..'.,--PROJECT Applicant: Square Footage: INFORMATION;4 .. } Site Address: 1883 16TH ST 30605 SORREL LANE Owner: Permit NO: B 17-2981 APN: 030-063-002 9513210855 SPRADLIN THOMAS E & CHER 0 0 0 Permit type: MISCELLANEOUS (1 a. f' OWNER / BUILDER 1883 16TH ST Issued Date: 12/18/2017 By JMD Subtype: SOLAR ROOF -RES the reason(s) indicated below by the checkmark(s) I have placed next to the applicable item(s) (Section OROVILLE, CA 95965 Expiration Date: 12/18/2018 Description: SOLAR ROOF - RES (4.2KW) is State License Law (Chapter 9 (commenting with Section 7000) of Division 3 of the Business and , in full force and effect. Occupancy: Zoning: Contractor Applicant: Square Footage: FREEDOM SOLAR SERVICES DBA FREEDOM SOLAR Building Garage Remdl/Addn 30605 SORREL LANE 30605 SORREL LANE 0 0 0 CANYON LAKE, CA 92587 CANYON LAKE, CA 92587 Other Porch/Patio Total 9513210855 9513210855 0 0 0 LICENSED CONTRACTOR'S DECLARATION :' (1 a. f' OWNER / BUILDER DECLARATION _. Contractor (Name) - State Contractors License No. / Class / Expires `I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for FREEDOM SOLAR 982892 / C10 / 4/30/2019 the reason(s) indicated below by the checkmark(s) I have placed next to the applicable item(s) (Section 7031.5, Business and Professions Code: Any city or county that requires a pernit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' I HEREBY AFFIRM UNDER PENALTY OF PERJURY that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license i is State License Law (Chapter 9 (commenting with Section 7000) of Division 3 of the Business and , in full force and effect. Professions Code) or that he or she is exempt from licensure and the basis for the alleged exemption. X Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): I, as owner of the property, or my employees with wages as their sole compensation, will Contractors Signature Date do L) all of or L) portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the ` WORKERS' COMPENSATION DECLARATION" ; I HEREBY AFFIRM UNDER PENALTY OF PERJURY one of the following declarations: I have and will maintain a certificate of consent to self -Insure for workers' burden of proving that it was not built or compensation, Issued by the Director of Industrial Relations as provided for by Section improved for the purpose of sale.). • 3700 of the Labor Code, for the performance of the work for which this permit is issued. Policy No. E]cI, as owner of the property, am exclusively contracting with licensed Contractors to Elhave and will maintain workers' compensation Insurance, as required by Section 3700 of onstruct the project (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who the Labor Code, for the performance of the work for which this permit is issued. My workers' contracts for the projects with a licensed Contractor pursuant to the Contractors' State License compensation insurance carrier and policy number are: Law.). Cartier. STATE Policy Numb90g29d6 Exp. 12MIM/2018 ' I am exempt from licensure under the Contractors' State License Lawforthe following El ❑reason I certify that, In the performance of the work for which this permit is Issued, I shall not employ any person in any manner so as to become subject to the workers' compensation; laws of California, and agree that, if I should become subject to the workers' X compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those n Owner's Signature Date provisions. X`".*�. • +' PERMIT APPLICANT. DECLARATION - Signature Date By my signature below, I certify to each of the following: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS I am U a California licensed contractor or U the property owner' or U authorized to UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES the property owner's behalf". I ct have he read this construction permit application and the information I have provided is AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ' correct. ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN t agree to comply with all applicable city and county ordinances and state laws relating SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. to building construction. I authorize representatives of this city or county to enter the above -identified property for inspection purposes. California Licensed Contractor, Property Owner* or Authorized Agent": 'requires separate verification form "requires separate 3CONSTRUCTION LENDING AGENCY DECLARATION'.`. I hereby affirm under penalty of perjury that there is a construction lending agency for the authorization form ' performance of the work for which this permit is issued (Section 3097, Civil Code). Lenders Name and Address X " Lenders Name & Address City State Zip FEE INFORMATION Total Fees: $511.00 Fees Paid: Balance Due: (None) Job Value: $511.00 $15,000.00 k + Y , • r $511.00 $15,000.00 k + PV SYSTEM SUMMARY: 4.200 KW ROOF MOUNT RESIDENTIAL PHOTOVOLTAIC SYSTEM SYSTEM SIZE (DC) STC: 14 X 300= 420OW DC PTC: 14 X 276.58 = 3872.12W DC SYSTEM SIZE (CEC-AC) 14 X 276.58 X 98% = 3794.68W AC MODULES 14 X HANWHA Q -CELL. Q PEAK -G4.1 300, 300W MODULES , INVERTER SOLAR EDGE SE380OH-US ROOF ROLLED COMPOSITION' - TILT 5' PITCH AZIMUTH : 180° RAFTER/TRUSS SIZE : 2" X 6" RAFTERS @ 24" O.0 ATTACHMENT TYPE CHEM CURB WITH TILT KITS WITH IRONRIDGE XR100 RAIL MAIN SERVICE PANEL EXISTING 125 AMPS MSP WITH 100 AMPS MAIN BREAKER ON BOTTOM FEED INTERCONNECTION PV BREAKER TIED INTO MSP OCPD RATING 20 AMPS STRINGING 1 STRING WITH 14 MODULES IN SERIES IN EACH STRING UTILITY PACIFIC GAS AND ELECTRIC COMPANY (PGE) TABLE OF CONTENTS PV -1 SITE LOCATION AND HOUSE AERIAL VIEW PV -2 SITE PLAN PV -2A ROOF PLAN WITH MODULES LAYOUT PV -3 ELECTRICAL LINE DIAGRAM PV -4 ROOF MOUNTING DETAILS, ELEC. CALCULATION & MATERIAL LIST PV -5 LABELS PHOTOVOLTAIC SYSTEM CITY NOTES: THIS PROJECT COMPLIES WITH THE FOLLOWING: 2016 CALIFORNIA BUILDING CODE (CBC) 2016 CALIFORNIA ELECTRICAL CODE (CEC) 2016 CALIFORNIA FIRE CODE (CFC) 2016 CALIFORNIA PLUMBING CODE '2016 CALIFORNIA MECHANICAL CODE 2016 CALIFORNIA ENERGY CODE 2016 CALIFORNIA RESIDENTIAL CODE 2016 CALIFORNIA ADMINISTRATIVE CODE AS ADOPTED BY COUNTY OF BUTTE ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT POSSIBLE.AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY ARE MOUNTED VISIBLE PORTIONS OF THE SOLAR PANEL SUPPORT STRUCTURE AND ANY EXPOSED' ELECTRICAL CONDUITS, BOXES AND PANELS WILL NOT BE EXPOSED, AND WILL BE COLORED MATCHED TO EXISTING ROOF OR SURROUNDING HOME. MODULES SHALL BE TESTED, LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN ACCORDANCE WITH UL 1703. THE FIRE CLASSIFICATION SHALL COMPLY WITH TABLE 1505.1 OF THE CALIFORNIA BUILDING CODE BASED ON THE TYPE OF CONSTRUCTION OF THE BUILDING. CRC SECTION R902.4 SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED.PER CRC SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. RESIDENTIAL BUILDING UNDERGROUND ADDITION OR IMPROVEMENTS SHALL REPLACE NON-COMPLIANT PLUMBING FIXTURES WITH WATER CONSERVING PLUMBING FIXTURES IN ACCORDANCE WITH CGBSC SECTION301.1.1 AND CIVIL CODE 1101.1 AS FOLLOWS: —WATER CLOSETS: 1.6 GPF (GPF= GALLONS PER FLUSH) —FAUCETS (ALL INTERIOR) 2.2 ( GPM = GALLIONS PER MINUTE) —URINALS 1.0 GPF —SHOWER HEADS 2.5 GPM INSTALLATION NOTES: THE PV BREAKER SHALL NOT EXCEED 120% OF THE ALLOWABLE BACK FEED OF THE MAIN SERVICE BUSS RATING. PV WIRE SHALL BE USED ON DC RUNS FOR UNGROUNDED/TRANSFORMERLESS INVERTERS. ` INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. 'r EMT CONDUITS ARE ATTACHED TO THE ROOF USING PRESSURE TREATED WOOD IN CASE OF COMPOSITE ROOF OR CO.UNDUIT HANGERS IN CASE OF CONCRETE ROOF SITE LOCATION: Mountain Vista Di ' Vista�te Ct w ': i . • 18831`6th Street s _ :Cres Dt • - c 7 17 . 41 +M.Y.4. �w • m Vista pr "" - SITE LOCATION HOUSE AERIAL VIEW: Q� Elocri a!Cmj,,0crNo: CLIENT: REVISIONS: TITLE: SHEET: C-10 982892 DATE: 12/14/2017 . •..:,; .. Freedom Solar SPRADLIN, CHERYL & THOMAS DESCRIPTION DATE REVISION 1883 16TH ST, DESIGN GREGSITE LOCATION AND P� /_1 Freedom Solar Co OROVILLE, CA 95965 BY: HOUSE AERIAL VIEW V 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 (530) 513-3490 Tel: (800) 385-1075 JOB No.: FS -12-048 ROOF AREA STATEMENT ROOF MODTUYLES PITCH AZIMTUH ROOF AREA ARRAY AREA 1 14' 5° 180° 722.77 SQ FT 253.58 SQ FT ® O � NOTE: • EMT CONDUIT SUPPORTED BY PIPE' « Q HANGERS 12" TO 18" AWAY FROM ROOF EDGE ATTACH CLAMP AT 25% FROM EDGE AND FROM CENTER OF MODULES' ® JUNCTION BOX MOUNTED TO THE RAIL 4,-9,. r 2" X 6" RAFTERS @ 24"O.0 (TYP.) Q(N) ATTACHMENT POINTS @ f 72" O.C. MAX. _ NZ (N) 14 HANWHA Q -CELL. Q PEAK=G4.1 300, 300W MODULES - — - — — — 2' 00, llmm"- Q(N) JUNCTION BOX • T7' FIRE ACCESS POINTS (N) SOLAR EDGE SE380OH-US INVERTER (E) MAIN SERVICE PANEL ROOF PLAN WITH MODULES LAYOUT 1 (N) AC DISCONNECT SCALE: 1/8" = V-0" F25819 E1ocricaiconuoa° No: CLIENT: REVISIONS: TITLE: SHEET:s., Freedom Solar C-10 982892 SPRADLIN, CHERYL& THOMAS DATE. 12i1ai2o17DESCRIPTION DATE .REVISION1883 16TH ST, DESIGN ROOFPLAN WITHFreedom SOIar Co OROVILLE, CA 95965 BY: GREG PV -2/q(530) 513-3490 MODULES LAYOUT Jefferson Ave, Suite 110,.Murrieta, CA 92562 a, ' Tel: (800).385-1075 t JOB No.: FS -12-048 .Max. CCPD: (125A Bus)' (1.2) = 150A Max Rating (120% of Bus) , PV Backfeed (20A) + Main Breaker (100A) _ (120A:5 150A) - See 705.12 (D)(2)(3)(b) of 2016 CEC (E) 125A MAIN SERVICE PANEL 2 - #10 AWG, THWN-2 1 - #8 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT 20A / 2P i PV BREAKER INVERTER SOLAR EDGE • SE3800H-US • (E) 100A / 2P _ - � MAIN BREAKER ` RAPID SHUTDOWN STRING -1 AC SWITCH J 14 HANWHA Q -CELL Q PEAK=G4.1 30A AC 300, 300W MODULES DCDISCONNECT-' . DISCONNECT m UTILITY JUNCTION METER BOX------------- ------------ — �� —------------------------ " '-- L SOLAREDGE P320 3 - #10 AWG, THWN-2 I j POWER OPTIMIZERS 1 -#8 EGC, THWN-2 L---------------- IN 3/4" OR LARGER EMT CONDUIT I 17 11 L— — — — — — — — — — — — — — — — — 2 - #10 AWG, PV WIRE 1 - #6 EGC, BARE COPPER - CONNECT TO EXISTING LIFER General Notes 1. (14) HANWHA Q -CELL. Q PEAK -G4.1 300, 30OW MODULES wired and listed to UL1703 standards 8. System Grounding Electrode conductor for PV system to be sized to meet the requirements of CEC 2016 table 250.66, not smaller than #8 CU AWG. 2. SOLAR EDGE SE380OH-US Inverter with integrated DC Disconnect and Arc Fault Protection. Attached with system electrical specifications and ground fault protected & listed to UL1741 standards. 9. If the existing main service panel does not have a ground rod or ufer, it is the pv contractors responsibility install one. 3. Photovoltaic system ground will be tied into existing ground at main -service from DC Disconnect/Inverter as per CEC 10. Smoke alarms and carbon monoxide detectors will meet the necessary requirements per CRC R314, R315 Sec. 250.166(A). "The Grounding Electrode Conductor shall not be smaller than the neutral conductor and not smaller than 8AWG copper." 11. UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM. 4. Equipment operating 150 volts or greater shall only be serviced or replaced by qualified personnel. Field protection may 12.Terminals of the disconnecting means may be energized in the open position. be in the form of conduit, closed cabinet or an enclosure which requires use of tools to open. ' 13. A signage labeled "SOLAR LOADS ONLY" is to be installed on dedicated solar sub panel to be used for PV only. 5. Solar Photovoltaic System equipment will be installed in accordance with requirements of Art. 690 of the 2016 CEC. ` 14. Solaredge inverters are listed to UL1741 and UL1699B standards. 6.Minimum height of conduit above roof to match temperature derating factor. 15. Solaredge Optimizers are listed to IEC62109-1 (class II safety) and UL1741 standards. 7.Photovoltaic DC conductors entering the building shall be installed in metallic raceway and shall be identified every 10 feet -- and within 1 foot above and below penetrations of roof/ceiling assemblies, walls, or barriers — with minimum 16. PV system is using continuous grounding method with #6 bare copper wire. 3/8 -inch -high white lettering on red background reading:"WARNING: PHOTOVOLTAIC POWER SOURCE" Elwriwl catwo Na. CLIENT: REVISIONS: TITLE: SHEET: �^( ;•'. F,�oSola� c-10982892 SPRADLIN, CHERYL & THOMAS DATE. 12/14/2017 O DESCRIPTION DATE REVISION 1883 16TH ST, DESIGN GREG ELECTRICAL PV -3 Freedom Solar Co OROVILLE, CA 95965 BY: 25819_ Jefferson Ave, Suite 110, Murrieta, CA 92562 (530) 513-3490 LINE DIAGRAM Tel: (800) 385-1075 JOB NO.: FS -12-048 ELECTRICAL CALCULATIONS MATERIAL LIST M-1 Structural Sealant ` - Along Pipe Minimum 1" Between -Pipes & Chemcurb 1- PART Pourable BACKFEED BREAKER SIZING 7.5 or 5.0 Sealer MAX. CONTINUOS OUTPUT 16A @ 240V or PRO PACK 16 X 1.25 = 20.00AMPS 20A BREAKER - OK Chem Curb 2.0 1l0 Above Pourable Sealer Penetration CEC 705.12 (D) (2) (3) (b) 2,0 125 X 1.20 = 150 Roof Surface 150 - 100 = 50A ALLOWABLE BACKFEED, Minimum 1" DE -RATED AMPACITY.OF10AWG CONDUCTOR @ 0.87 ' Between Pipes TEMPERATURE CORRECTION - M-1 Structural Sealant M-1 Structural Sealant 40 X 0.87 = 34.80 AMPS - OK PHOTOVOLTAIC MODULE IRONRIDGE TILE IRONRIDGE RAIL ® 15° ASSEMBLY QTY EQUIPMENT DESCRIPTION OPEN CIRCUIT VOLTAGE (Voc) : 39.76V HANWHA Q -CELL. MAX. POWER VOLTAGE (Vmp) : 32.41V 14 Q PEAK -G4.1 300, SHORT CIRCUIT CURRENT (Isc) : 9.77A 30OW MODULES MAX. POWER CURRENT (Imp) : 9.26A PTC RATING: 276.6W SOLAR EDGE MAX. DC INPUT VOLTAGE: 350V SE380OH-US MAX. AC OUTPUT VOLTAGE RANGE: 211-240V 1 MAX. AC OUTPUT CURRENT.: 16A WITH POWER MAX. AC POWER OUPUT : 3800W OPTIMIZER CEC EFFICIENCY: 98% 1 JUNCTION BOX 60OVDC, NEMA 4X, UL LISTED 1 AC DISCONNECT 600VAC, 30A, NEMA 3R, UL LISTED 1 PV BREAKER 2 POLE, 240V, 20A 42 ATTACHMENTS CHEM CURBS WITH TILT KITS 150' RAIL IRONRIDGE XR100 IRONRIDGE XR100 GROUNDING 14 MID CLAMPS MID CLAMPS 28 END CLAMPS IRONRIDGE XR100 END CLAMPS 40' CONDUIT 3/4" OR LARGER EMT CONDUIT (E) ROOF MEMBRANE E -CURB SYSTEM COMPONENTS 5/16" LAG SCREWS WITH 2.5" MIN. EMBEDMENT- Photovoltaic MBEDMENT Photovoltaic Panel Mounting Detail Scale: NTS , --J c— :E1wdmjCoft­tor]No:CLIENT: REVISIONS:TITLE: SHEET: Freedom Solar SPRADLIN, CHERYL & THOMAS DESCRIPTION DATE REVISION DATE: 12/14/2017 ROOF MOUNTING 1883 16TH ST, DESIGN GREG DETAILS, ELEC. PV_4 Freedom Solar CO OROVILLE, CA 95965 BY: ALCULATION & 25819 Jefferson Ave, Suite 110, Murrieta, C (530) 513-3490 ' Tel: (800) 385-1075 Job No.: FS -12-048 MATERIAL LIST LABELS: LABELS SPECIFICATION: 1. ALL CAPITAL LETTERS 2. MINIMUM 3/8" LETTER HEIGHT 3. ARIAL OR SIMILAR, NON -BOLD 4. WHITE LETTERING IN RED Max. Current per Pole BACKGROUND 5. WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (DURABLE ADHESIVE MATERIALS MUST MEET THIS REQUIREMENT 6. ALL SIGNS SHOULD BE REFLECTIVE . I� CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING WARNING SOURCES WITH DISCONNECTS LOCATED AS SHOWN TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL R ® 01 n m m m 14 PV MODULE --\ m JUNCTION BOX J INVERTER EQUIPPED WITH RAPID SHUTDOWN — MAIN SERVICE PANEL AC DISCONNECT Elmrim! Ccn"dnNa. CLIENT: �.. Freedom Solar 1 C-10,98280 Freedom Solar Co 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 Tel: (800) 385-1075 DISCONNECTION MEANS ALL AC AND DC DISCONNECTS TO BE MARKED AS DISCONNECTING MEANS PER CEC 2016 690.13(B) AC DISCONNECT PHOTOVOLTAIC DISCONNECT FOR UTILITY OPERATION INVERTER OUTPUT CONNECTION T E INSTALLED AT MAIN SERVICE PA PER CEC 2016 705.12(D) MARKING SHOULD B, CED.. ALL INTERIOR AND EXTERIOR P1"CONDUIT, RACEWAYS, ENCLOSURES; AND CABLE ASSEMBLIES, EVERY 10 FEET, -AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS AND ALL PV COMBINER AND JUNCTION BOXES. WARNING PHOTOVOLTIC POWER SOURCE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION; TO BE INSTALLED AT DISCONNECTING MEANS PER CEC 2016 690.17 WARNING ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. ; PHOTOVOLTAIC POWER SOURCE SHALL BE LABELED WITH THE FOLLOWING WARNING AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT, AND DEVICE WHERE , ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE PER CEC690.35(F) WARNING ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. SPRADLIN, CHERYL & THOMAS 1883 16TH ST, OROVILLE, CA 95965 (530)513-3490 WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAYBE ENERGIZED WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE 690.12 COMPLIANT [PHOTOVOLTAIC SYSTEM, EQUIPPED WITH RAPID SHUTDOWN DIRECT-CURRENT PHOTOVOLTAIC POWER SOURCE TO BE INSTALLED AT INVERTER PER CEC 690.53 OPERATING CURRENT: 8.99A OPERATING VOLTAGE: 350.00V SHORT-CIRCUIT CURRENT: 11.93A MAX SYSTEM VOLTAGE: 500.00V AC DISCONNECT PHOTOVOLTIC DISCONNECT FOR'UTILITY OPERATION WARNING ELECTRIC SHOCK HAZARD CONTACT QUALIFIED SERVICE PERSONNEL FOR ASSISTANCE Nominal Voltage 240 Volts Nominal AC Frequency 60 Hz Maximum AC Power 3800 Watts Maximum AC Current 20.00 Amps Max.Overcurrent Device 20 Amps Max. Current per Pole 20.00 Amps REVISIONS: DESCRIPTION DATE I REVISION TITLE: DATE: 12/14/2017 DESIGN GREG BY: LABELS JOB NO.: FS -12-048 SHEET: PV -5 powered byMECHANICAL SPECIFICATION Format 65.7in x 39.4in x 1.25in (including frame),m�; ,� `" ri ,•„r ydr1.. >I'- .a 1 T• (1670mm x ]OOOmm x 32mm) '�.. Weight 41.45 lb (18.8 kg) • �° wh$+. •1.. ' `r r + r ' r.- i (y* Ir. QFrond Cover 0.13 in (3.2 mm) thermally pre stressed glass with anti-reflection technology o-,,,°,,,.,, r Back Cover - Composite film r ' •"' ".• T - '•,' . - Frame - Black anodised aluminum f. - -- _ .,,.a.. - •r -p - Cell 6 x 10 monocrystalline O.ANTUM solar cells - r.`_ { r Junction box 2.60-3.03 in x4.37-3.54inx0.59-0.75in(66-77mmx 111-90mmx e ' �' A 15--19mm), Protection class IP_67, with bypass diodes a ri TtT Cable 4mm, Solar cable; l+)a39.37in(1000mm)(-)a3937inf1000mm) +� "v _n y{ '•�Fi'^ % - - I Connector Multi-Contact MC4 or MC4 intermateable, IP68� µ „arw,.,rIOI^°�'•�-+ r' - • • 1- I ♦ • ' - n y�,y� 5{'1 � - - POWER CLASS r 295 u•. 300 305 { • MINIMUM PERFORMANCE AT STANDARD TESTING CONDITIONS, STCI (POWER TOLERANCE +5W/-OW) r x .i Power at MPP' Px„ [W] 295 300 1 305 L • L ' L • ''. Short Circuit Current* -- • lar =_ [A]� _ ^.. 9.70 ` 9.77 ` _ - 9.84 ' . eOpen Circuit Voltage*, V. IV] •, 39.48 _ ' 39.76^� 40.05 Current at MPP" • Iw [A] ~ 1 - 9.17 - 9.26 9.35 4 t Voltage at MPP* vae,! IV] 32.19 - 32.41 32.62 The new high-performance module Q.PEAK-G4.1 is the ideal solution for. - _ - - - -- " 1 4 ENicienCyz k- 111 t%] >_ 17.7- �_ 18.0 =18.3 `. all applications thanks to its innovative cell technology UNTUM Ultra. s, MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NDC° ` The world-record -cell design was'developed to achieve the best perfor- , Power at MPP° - Pr1„ [W1� - 218.1 F ~221.8 - 225.5 mance•under real conditions - even with low radiation intensity and on r short Circuit Current* µ, - laa:,x [A] �4 ` 7.82T y 7.Sa 7..94 clear, hot summer days. - - 9 Open Circuit Voltage* A °rc V. IV)- � - 36.92 . -_ - 37.19 T 37.46 ♦ C 2 ^ Current at MPP' 1x11 [A] 7.20 7.27 7.351 r LOW ELECTRICITY GENERATION COSTS _ Voltage at MPP* ^ _ -- Vw, [V] y 30.30 30.49 Y +30.67 ' '1000 W/m1, 25 °C, s;.I,um AM 1.5G 1101;Zemenl tolerances STC t3-%: NOC t5 �, '800 W/m1, NOCT spectrum APA 1.5G "typical values, actual values may differ • Higher yield per surface area and lower BOS costs thanks to - -,.., - - a -+_ •- < a • ' 1• Q CELLS PERFORMANCE WARRANTY r - PERFORMANCE AT LOW IRRADIANCE ' higher power classes and an efficiency rate of up to 18.6- ' At least 17% of nominal power during first year. 10 -'T-----; -----; ----- ' Thereafter max. 0.6% degradation per year, l p e W , INNOVATIVE ALL-WEATHER TECHNOLOGY f W = a "' ---- At least 92% of nominal power up to lO years. y Optimal yields, whatever the weather with excellent low-light At least a3% of nominal power up to 25 years. E 'm y� • =z All data within measurement tolerances. o---____�____ ;_____ _____ and temperature behavior. � Full warranties in accordance with the warranty terms of the Q CELLS sales organization of your respective country. am ENDURING HIGH PERFORMANCE u aro 000 IRRADIANCE [WWI Long-term yield security with Anti-PID Technology', Hot-Sp ot- any Protect d Traceable Qualit Tra.QTM. m p YEARS Typical module performance under low irradiance conditions in i - - . ................ ..:a.,..,..mu: comparison to STC conditions (25 °C, 1000 W/m1). 4 TEMPERATURE COEFFICIENTS ti EXTREME WEATHER RATING QCELLS \` nrmuamm Temperature Coefficient of lu. - ffl o [%/Kl +0.04 Temperature Coecield of V. p [%/Kl -0.28 N ' High-tech aluminum alloy frame, certified for high snow oPeRnyogv. Temperature Coefficient of P. V [%/K) -0.39 Normal OperadnCellTemperature , , NOCT [°F]~ -113 t 5.4 (45 m 3 °C) $(5400 Pa) and wind loads (4000 Pa) regarding IEC. Y�11Ei. -PROPERTIES FORDESIGN MAXIMUM COST REDUCTIONS Maximum System Voltage Vm M1 [V1 1000 (IEC) / 1000 (UL) Salary Curse - - _ .- - T . II - r ^ Up to 10% lower logistics costs due to higher module Maximum Series Fuse Rating- [A OC1 20 Fire Rating - ` y C (IEC) / TYPE 1 (UL) c Design load, push (UL) [lbs/1111 75 (3600 Pa) Permitted module temperature -40'F up to +185°F capacity per box. on continuous duty - (-40°C up to+85°C) o Phntnn. . Design load, pull (UL)2 [lbs/ft1] 55.6 (2666 Pa) a see installation manual O A RELIABLE INVESTMENT o aaBresEeaf ctcal� :. -.. _ - - _ m • n , Beat polycrystalline solar module 2014 QUALIFICATIONS r 1 PACKAGING , , r , r Inclusive 12-year product warranty and 25-year ,.s araaaz2as linear performance guarantee 2. ID. 4003zse7 UL 1703; VDE Quality Tested: CE-compliant; Number of Modules per Pallet - � T 32 - • i •-- -- . .. - •- - IEC 61215 (Ed.2): IEC 61730 (Ed.l) application class A -- - ` •Number of Pallets per 53' Container 32 V e Number of Pallets per 40' Container �TT r 26 * o y' APT test conditions: Cells at -1500V C F c .. t_ . _ _- .,- -, _ . K ,-r - - . A­ .. against grounded, with conductive me- D E ` ` c ,, uS Paflet Dimensions (L x W x H) 68.7 in x 45.3 in x 46.1 in . (1745 x ] 150 x 1170 mm) tal foil covered module surface, 25°C, , 2 TME IDEAL SOLUTION FOR: 168h Pallet Weight 1435 lbs (651 kg), _ _ Rooftop arrays on s See data sheet On rear for further NOTE: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use ® information of this product. . r a residential buildings Y - Hanwha Q CELLS America Inc. _ y • 300 Spectrum Center Drive, Suite 1250, Irvine, CA 92618, USA I TEL +1 949 748 59 96 1 EMAIL inquiry®us.q-cells.com I WEB www.q-cells.us - Engineered in Germany E OCELLS'. r,, solar=90 SolarEdge Single Phase Inverters ` for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / SE760OH-US ce 5 x - s Z b ' • •F `•1 �pptq m f o a �y •:' W .r ,y �r 'r S '• .fir./.: .••µr ��.. � : �r •:'1�+F � -• y t =@@ solarSE3000H-US Single Phase Inverters for North America Vac SE380OH-US/SE5000H-US/SE6000H-US/SE760OH-US . I OUTPUT SE3000H-US SE3800H-U5 SE5000H-US SE6000H-US SE7600H US i Rated AC Power Output 300D 3800 5000 6000 760D VA ............................................................................................... AC Power Output 3000 3800 5000 6000 7600 VA Optimized installation -with HD, Wave technology.,. r» u -,,Record, breaking breaking efficiency '` `�, ' "° t r„Iritegrated arc fault protection for NEC 2011690. 11 and integrated raped shutdown for NEC 2014 69012*71 * , c -„Extremely sinal 4 y •. J -� High reliability without any electrolyte capacitors ='Built in module -level monitoring- +-Outdoorand indooryfristalletion T� t: i `V vvave a • •a =•Optional Revenue grade data,'ANSI 12:2 I ( ° y) C 0 Class 0 5 0.5/6 accuracy), Optional. Self -Sustaining Power produce up.to 1. kW directly from PV during grid failure',: y• T = USA-CANADA-GERMANY-ITALY•FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS -UK -ISRAEL -TURKEY -SOUTH AFRICA -BULGARIA www.solaredge.us 0 .................................................................................................................................................................. AC Output Voltage Min: Nom: Max. (183 - 208 - 229) ✓ Vac AC Output Voltage Min. -Nom. -Max. (211- 240 - 264) ✓ ✓ ✓ ✓ ✓ Vac AC Frequency (Nominal) ...... 59.3 60 - 60.51`” Hz ........................................................................................................................................................ Maximum Continuous Output Current 208V 24 ........:..................... A Maximum Continuous Output Current 240V .......................... 12.5 I 16 21 _5 32 ..................................... A GFDI Threshold 1' A ..............................................................................................Yes............................................................ Utility Monitoring, Islanding Protection, - Country Configurable Thresholds I INPUT Maximum .DC Power .... ...........ess.................................. 4650 5900 7750 9300 11800 . ............................................................................ ................ W .......... U....... Transformerd Ungrounded rounded Yes M xim m In V I ....a......... Put..°..ale..................l........-....:........:.......................................................... 480 .... `....................:............................... Vdc Nominal DC Input Voltage ” 380 400 .... Vdc Maximum Input Current 208V ........................... .............. ... .......... ......... .......................... Adc ........... Maximum . .. Input .Cu.rre.nt.. 240V. ..... .................... ........ ... 8.5 10.5 13.5 16.5 20 Adc Max. Input Short Circuit Current ......................... 45 ......... ......... .....-... ....... ..Yes................ ......... ......... ....... "Adc R verse-Polarit Protection ...............Y............................................................................. .......... ............................................................... Ground Fault Isolation Detection 600ka Sensitivity Maximum Inverter Efficiency .......99......... I .................. ................. ..................................... ..... %..... CEC Weighted Efficiency ' 99 ............................................................... % Nighttime Power Consumption < 2.5 W 1SELF-SUSTAINING POWER OUTLET (OPTIONAL) Nominal Output Voltage -------•................................................................. 120V ... .............................................. ........................... .......... Maximum Output Power .............................................................................. 1500tzj W .................................................... External Outlet with GFDI I Yes ' f ADDITIONAL FEATURES S rt d Communication Int rf c UPp°..e............e a es R 48 Ethernet, Zi B (optional) tional .......................5.. ...........g......... a. . °P......).........=.- Internal RGM support ............................................................................... AN51 C12.20 class 0 5 compliant......... Rapid Shutdown- NEC 2014 690.12 Automatic Rapid Shutdown ISTANDARD COMPLIANCE 2 Safety .......... UL1741, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 ....... -...-....... ............................ ......... ..... .............................................. Grid Connection Standards ..... IEEE1547, Rule 21, Rule14 (HI) ................................................................................................ Emissions FCC Part 15 Class B i.INSTALLATION SPECIFICATIONS AC Output Conduit Size /AWG Range 0.75-1" Conduit/ 14-6 AWG ........... R............................................................................. WG ............................ . ...CInp' ..........'Siz*e ..........gs / AWG DC Input Conduit Size. N of Strings /AWG Range 0.75-1°' Conduit /1-2 strings..14.. AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 in/mm ........................................... ....g............ y.................................................................... ► Wei ht with Safet Switch 25..3./.1.1..5 Ib / kg ............................................................................. Noise < 25 dBA ......................... Cooling Natural Convection ...........................................................................................•.ii1..'.-......................_............................... Operating Temperature Ranke : 13 to +140 / 25 to +60 (40'F / 40 C option) F / °C ...................................................................... Protection Rating NEMA 3R (Inverter with Safety Switch) ...... ...................................................................................................................................:......................... For other regional settings please contact SolarEdge support Depends on PV availability 13j Powei de -rating Irom 50Y ' s ' • solarK00 P • •_ �- ": Sol'arEdge Power Optimiie,r Module Add -On For. North America P300 / P320 / P400 / P405 USA - CANADA -GERMANY - ITALY - FRANCE - JAPAN - CHINA - AUSTRALIA - THE NETHERLANDS - UK - ISRAEL - TURKEY - SOUTHAFRICA- BULGARIA www.solaredge.us So I are WO- SolarEdge Power Optimizer r Module Add -On for North America , -P300 / P320 / P400 / P405 P300P320 xs P400 P405 I - - (for 60 -cell modules) . . 1,+rs� !, •*` it R�. ••�� - • _, RV, power optimization at the�module— level .�+. (for thin-film_ y • .. _ v -" Up to 25 /o more energy - —"Superior efficiency (99.5/0) modules) 41 .Mitigates all types of module mismatch losses, from manufacturing 'tolera'nce to partial shading+"r'•, +' Rated Input DC Powerl`L r - F exlble`system design -for maximum space utilization W - �, ♦ .- .'•r� - . �.• yn s��[i .. � ' '-,}fast installationn-with a single bolt.4 - - - -`Next generation maintenance with module -level momtoririg ' ' `' r a - 5' ............. • ' ' is 8 - 48...................... ........?.8.: $0..... 12.5 - 105 rAdc —`Module=level voltage`shutdown for installer end firefighter safety. ................. 1' + • Maxlmurn Short Circuit Current (Isco �`, Via:• •a " •t • ,.ti ♦ .. T .LTa ,.f ... ............ -............... ........................... ,3,*...................... v 12.5 13.75 12.63 ...................................... ..................................................... USA - CANADA -GERMANY - ITALY - FRANCE - JAPAN - CHINA - AUSTRALIA - THE NETHERLANDS - UK - ISRAEL - TURKEY - SOUTHAFRICA- BULGARIA www.solaredge.us So I are WO- SolarEdge Power Optimizer r Module Add -On for North America , -P300 / P320 / P400 / P405 Ie Rated STC power of the module. Module of up to +5% power tolerance allowed. PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTER(" Minimum String Length 8 10 18 (Power Opti-mizers)................ . ........................ ............ ................................... . Maximum String Length Power O timlzers 25 25 50 ( ) Maximum Power per String 5250 6000 12750 W Parallel Strings of Different Lengths Yes ................................... ............. or Orientations ................................................................................................................................................................. . RI It is not allowed to mix P405 with P300/P400/P600/P700 in one string' , CE E� O Sola,Edgc Tcr-hirolagics. Inc. All nghts «. sen er.. SO LAREDGE, the SclarEdgr. logo. OpTIh9ZED BY�SOIAREDGE are tredenlarps o rue.i3tered trademark JolnrEd�e TeclmWogirlhic�All oth lradelnarlca Mentioned herein are tracer+ants of Their resaenive own�17�01%20_7 KO7.*$iintert to change tvrhout rotice. 0 P300P320 P400 P405 I (for 60 -cell modules) (for high-power (for 72 & 96 -cell (for thin-film_ 60 -cell modules) modules) modules) )INPUT Rated Input DC Powerl`L 300 320 400 405 .............. ..... . W Absolute Maximum Input Voltage 48 480 125 Vdc (Voc at lowest temperature) ................................ ...................................... ......... ........................... .:.:...................... ............. • MPPT Operating Range 8 - 48...................... ........?.8.: $0..... 12.5 - 105 rAdc Vdc ................. 1' + • Maxlmurn Short Circuit Current (Isco ....:.................. ................ 10 11 10.1 ... . - �. a ...D p ................... Maximum DC In ut Current ............ -............... ........................... ,3,*...................... v 12.5 13.75 12.63 ...................................... ..................................................... .. A -d ... .Adc Maximum Efficiency .........g ...... ................... 99.5 ./...... a Weighted Efficiency ................... 98.8 Overvolta a CategoryII {OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Out ut Current ' . 15 Adc ♦ Maximum Output Voltage 60' ( - ' 85 Vdc I OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTEDFROM SOLAREDGE INVERTER ORSOLAREDGE INVERTER OFF) + Safety Output Voltage per Power Optimizer 1 , : Vdc ) STANDARD COMPLIANCE EMC •, FCC Part15 Class Bi IEC61000 .6.2, IEC61000:6: 3 ............ Safety...................................1 ............ ....... ........IEC62109 1 (class II safety). UL1741 RoHS I Yes.. I.......... INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 -Vdc Compatible invertersAll ................... I....................... .. SolarEdge Single Phase and Three Phase inverters, :: ............ I - Dlrinensions(W X L x H) 128 x 152 x 27.5 / 128x152 x35/ 128x152x50/ r mm/in ............................................ Sx5.97x 1.08 Sx5.97x1.37 Sx5.97z1.96 ............................... ............. Weight (including cables) _ 630/1.4 750 / 1.7 845 / 1.9 .............................. .......... ......... . gr / Ib Input Connector MC4 Compatible Output Wire Type /Connector " Double Insulated; MC4 Compatible ..................................................... Output Wire Length .............. ... 0.95 / 3.0 ` 1 2 / 3.9 ............... ............. . .......................... m / ft . ..... Operating Temperature Range 40 - +85 / -40 - +185•C ......................................................I. /'F ...... Protection Ratin$IP68 / NEMA6P ........................................................................................................................ Relative Humidity 0 100 % Ie Rated STC power of the module. Module of up to +5% power tolerance allowed. PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTER(" Minimum String Length 8 10 18 (Power Opti-mizers)................ . ........................ ............ ................................... . Maximum String Length Power O timlzers 25 25 50 ( ) Maximum Power per String 5250 6000 12750 W Parallel Strings of Different Lengths Yes ................................... ............. or Orientations ................................................................................................................................................................. . RI It is not allowed to mix P405 with P300/P400/P600/P700 in one string' , CE E� O Sola,Edgc Tcr-hirolagics. Inc. All nghts «. sen er.. SO LAREDGE, the SclarEdgr. logo. OpTIh9ZED BY�SOIAREDGE are tredenlarps o rue.i3tered trademark JolnrEd�e TeclmWogirlhic�All oth lradelnarlca Mentioned herein are tracer+ants of Their resaenive own�17�01%20_7 KO7.*$iintert to change tvrhout rotice. 0 - - XR Rails 0, •� • . , ,, .. 1/lr'IRONRIDGE i% :Flush Mount System � r XR10 Rail XR100 Rail XR1000 Rail Bonded Splices T1Trr_ ..,� � �`s"- . -. �:. •'x bks "' t.,mss,,, ���+�" �J'y�:; •y'1 .� ~� 1 t• i� "� res I _ - . Alow-profile mounting rail -The ultimate residential A heavyweight mounting All rails use internal splices y G s "h y ";for regions with light snow. solar mounting rail. rail for commercial projects.- for seamless connections. 6' spanning capability 8' spanning capability 12' spanning capability •• Self -drilling screws z • x "` , •, ' - r '` „ ' , , N• Moderate load ca abilit Heavy load capability Extreme load'ca atiili •''Va' in versions for rails P Y Y P Y P tY •� + ry 9 Clea' &black anod. finish •Clear &black anod. finish •Clear anodized finish _ Forms secure bonding ° ,�* s.• ti ; �' tk .w '�. a-� , <_ C ' d r x.a'S5'' k'•E X - uz ' _ - • + ' : r Clamps & Grounding - • UFOs Stopper Sleeves Grounding Lugs -,- - Microinverter Kits J 100 s_f• ��..r• r tt -- - Universal Fastening Objects Snap onto the UFO to tum Connect arrays to Mount MIs or POs to XR — bond modules to rails. into a bonded end clamp:. equipment ground. • Rails. • r Fully assembled & lubed • Bonds modules to rails Low profile • -Bonds devices to rails ' Single, universal size • 6 different sizes Single tool installation • Kit comes assembled'. ; • Clear & black finish Clear & black anod. finish Mounts in any direction Listed to UL 2703 Built for solir's toughest roofs.- Att_achments'@ = - IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. +: FlashFoot2 Slotted L -Feet Bonding Hardware Flush Standoffs Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and _ is also why our products are fully certified, code compliant and backed by a 20-year.warranty. PE Certified Strength Tested —• - $,�S��, ; �. All components evaluated for superior ® - Pre -stamped engineering. letters Flash and mount XR Rails Drop-in design for rapid rail Bond and attach XR Rails Raise Flush Mount System structural performance. available in most states. with superior waterproofing. attachment. to certified attachments. to various heights. • Twist -on Cap eases install Secure rail connections • T & Square Bolt options • Works with vent flashing • - • Wind -driven rain tested Slot for vertical adjusting • -Nut uses 7/16" socket • 4" and 7" lengths Class A Fire Rating Design Assistant r • Mill &black finish Clear & black anod. finish • Assembled & lubricated •Ships assembled ti Certified to maintain the fire resistance ® Online software makes it simple to rating of the existing roof. Acreate, share, and price projects. Resources - Design Assistant $� - ,NABCEP Certified Training.. UL 2703 Listed System •20 -Year Warranty - , — r Go from rough layout to fully a' Earn free continuing education credits, NABCEP. engineered system. For free. while learning more about our systems. ® Entire system and components meet • Twice the protection offered by Go to IronRidge.com/design Go to IronRidge.com/training newest effective UL 2703 standard. �. competitors. 1 _ = _ , m r 3933 US Route 11 Intertek Intertek Cortland, NY 1304 • y. c ' �, Telephone: (607) 753-6711 Facsimile: (607) 756-9891, www.intertek.com Letter Report-1017035 54CRT=001SolarEdge TechnologieLid �+ o r' " j June 20, 2014 Letter Report No. 101703554CRT-001' June'20th,'2014 } * Project No. G 10 1703 554 t i _ • ,3 -ph Inverters: t ` Mr. Meir AdestPh: +972.9.957.6620 _ N . F , - r> o SE9KUS / SEIOKUS / SE20KUS when the SolarEdge rapid shutdown cable labeled 'MCI-CB-xxxxx- ;'i~ SolarEdge Technologies Ltd a e email: meir.a@soleredge.com ' . '' ` 6 Ha'Harash St. - 3' x" which is part of kit SE1000-RSD-xx is installed in the inverter Safety Switch where xxxxx-xx is . HOD HASHARON, ISRAEL any number; inverter part number may be followed by a suffix a , _ • `. Subject: ETL Evaluation of SolarEd a Products to`NEC Rapid Shutdown Re uiremenis * s ? ,r t.� „ • ;:" ' ~, ' r , - , ' ' ~ ?.,This letter report completes this portion of the evaluation covered -by Intertek Project No.G101703_554. Dear Mr.- MeirAdest, ' - a • "' ,? „ If there are any questions regarding the results contained in this 'ort, -or any; of the other services offered by This letter represents the testing results'of the below listed products to the'requirements contained in"the following ` ' Intertek, please do not hesitate to contact the undersigned. °' • ' standards: • ' , a . Please note, this Letter Report does not represent authorization for the use of any Intertek certification marks. - ~. National Electric Code, 2014, Section 690.12 requirement for rapid shutdown.t Completed by • Radhe Patel Reviewed by f Howard Liu • This investigation was authorized b signed Quote 500534459 dated 06/10/2014.Ra Id `shutdown test were ' f - Title 7- ,, 'V Engineering Team Lead ;Tit__.11"._,=" Staff Engineer 9 Y 9 PA • .perform at SolarEdge Technologies Ltd, 6 Ha'Harash St, NOD HASHARON, ISRAEL and witness by Intertek' J:`* r 3 • _�I1.,, �1 r� /! , personal on 06/17/2014. + ,_�' ; C.Ct�'/ `'= ':Signature .c_► : Signature t �Date� ' " 'June 20 , 2014 �` Date z1,+� x�- June 20 , 2014.., The evaluation covers installations consisting of optimizers and inverters with part numbers listed below. >� /tel, ' _. . The testing done has verified -that controlled conductors are limited'to riot more than 30 volts and 240 volt; _ f • amperes within 10 seconds of rapid shutdown initiation. Applicable products: • Power optimizers:. - o PBxxx-yyy-zzzz; where xxx is any number, 0-9, up to a maximum value where xxx = 350; yyy • .-� could be AOB or TFI; and zzzz is any combination of four letters and numbers. o OP -XXX -LV, OP -XXX -MV, OP -XXX -IV, OP -XXX -EV; where xxx is any.number, 0-9. - r o ' Paaa, Pbbb, Pccc; Pddd, Peee;.where aaa, bbb, ccc, ddd, eee is any number, 0-9 to a maximum' ' r , V upto aaa=300,.bbb=350 ccc=500, ddd=600, eee=700. _ • . '4 « a > s` w o Pxxx, Pyyy, Pzzz; Pmmm, Pnnrr and P000; where xxx, yyy, izz is any number; 0_910 a maximum + up to xxx=300, yyy=350, zzz=500; where mmm, nnn, 000 is any number, 0-9 to a maximum up to 'mmm=405; nnn=300, 000=350 • 1 -ph Inverters: ' o }SE3000A-US / SE380OA-US / SE5000A-US / SE6000A-US / SE760OA-US / SE10000A-U$ SE1140OA-US when the SolarEdge rapid shutdown cable labeled"MCI-CB-xxxxx-x" which is part ' of kit SE1000-RSD-xx is installed in the inverter Safety Switch where_ xxxxx-xx is any number; ` inverter part number may be followed by a suffix Y Page 1 of 2 ` This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terns r' - • - ` ' and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use. - r' `+ of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek: The observations and test results in this report are relevant only the sample tested. This = - ' •'�' ` a - . } . , s'✓ report by itself does not imply that the material, product or service is or has ever been under an Intertek certification program. BE4B Intertek 4 � ' ,. A •+ . ; � a . * C � ' " � ''f Page 2 of 2 • o o o - Intertek Intertek Intertek Intertek Intertek Intertek - Intertek Testing,Servlces NA, Inc. SD 12.1.2(11/11/10) Informative + Intertek Testing Services NA, Inc. SD 12.1.2 (11/11/10) Informative ' • •. - - �_ � . _ 1 '.- - - r _. _.. _ .rr •fry_- CHEM -LINK® � ^ � T� E -CURB SYSTEM Advanced Architectural Products PENETRATION SEALS C&n&cwtor vIj 6ye4ev Techtntcal ;Data Guide;; - . ; PolyetherTechnology.= ;'SCSI SectlorriNo 0.7 12 13 CHEM LINK Products, LLC Distributed by: BEST MATERIALS Ph: 800-474-7570, 602-272-8128 Fax: 602-272-8014 www.BestMaterials.com Email: Sales@BestMaterials.com Product Description E -Curb penetration seals replace old-style metal pitch pans with versatile, precast components and pourable sealants. CHEM LINK's E -Curb System can usually be installed in under 15 minutes and never requires flashing or mechanical attachment. E -Curbs are designed for use on granulated modified bitumen, asphalt and coal tar B.U.R. (built up roofing). E -Curbs are specified for PVC, EPDM, PIB, and TPO single ply roofing membranes. E -Curbs are highly versatile for sealing penetrations around solar panel mounts, HVAC, Electrical, and any type of structural supports. TPO Primer is required for use with TPO single -ply roof membrane. When installed properly, this system forms a durable, waterproof rubber seal around penetrations. An extended manufacture warranty against leaks is activated with submittal of a completed warranty card. Special Characteristics • Rapid installation - "Slip -fit" light weight curb design reduces labor significantly. • Excellent adhesion to most roofing materials. • No flashing or mechanical attachment required. • Service Temperature -40°F to 200°F (-40°C to 93°C) • 1 -Part° accommodates movement and is suggested for use on all granulated membranes and details with excessive movement. • For sloped roof applications, substitute DuraLinkTM non -slump adhesive/sealant for 1 -Part and M-1® Restrictions • Do not apply below 30°F (-1°C) • Do not install if rain is anticipated within 4 hours • Do not use on Hypalon or smooth APP modified bitumen membrane. For smooth APP, torch down a target of granulated APP before installation. • TPO Primer must be used for TPO applications. • Do not prime bonding surfaces with asphalt primer! • Do not use asphalt cement as a "night sealant." Use M-1 for this purpose. • E -Curb kits are designed to contain enough 1 -Part to fill each curb with displacement in consideration. Refer to our penetration calculator under contractor resources at chemlink.com to verify volumes. Last Revision: 02/20/13 Document No. L1350 E -Curb System Components • E -Curb exterior rings, straights, and corners. • M-1 Structural Adhesive/Sealant used for bonding the E -Curb components, sealing and priming the penetration. • 1 -Part "moisture cure" pourable sealer, used to forma durable, water -tight seal around the roof penetration. E -Curb precast form components are composed of light weight nylon resin. The E -Curb is 2 -inches high and is available in a variety of shapes and sizes. Sizes available include: bi-sected circular pieces having inside diameters of 3, 4, 6, or 9 inches. Corner pieces having a 2 -inch radius, and 8 -inch straight pieces are also available to create larger sizes. The outer surface is impervious to ice, corrosion, UV (ultraviolet) light and ponding water. M-1 Structural Adhesive/Sealant is a durable, self - fixturing moisture cure mastic. Cartridges of M-1 are supplied in each E -Curb Kit. Components are also sold separately. 1 -Part is a highly flexible, self -leveling moisture cure pourable sealer that eliminates mixing. It is also 100% solid rubber, has a very low VOC content, will not melt or shrink, and is resistant to deterioration. It is supplied in 10.1 -oz and 28 -oz cartridges or 1/2 gallon pouches. Unused sealant can be capped and reused. Step 1 Remove all previously applied caulk, mastic, cement, asphalt, and other contaminants from penetrations with a wire brush. Clean all smooth substrates with isopropyl or denatured alcohol. Brush away all gravel or loose granules. Seal the base of each penetration with M-1. Coat penetrations with M-1 to 3" above the roof line. Step 2 Hold a section of E -Curb, flat side up, and apply a 1/4" bead of M-1 to the entire bottom perimeter. Apply 1 additional 1/4" bead of M-1 down the center of the section. Do not tool the beads flat., Place the E -Curb section on the roof surface to form a half circle around the penetration(s). Press down firmly until M-1 extrudes from the outside edges. Step 3 Apply M-1 to the second section of E -Curb as described above. Place the second section of curb on the roof surface to form a circle with the first section. Press firmly in place until excess adhesive extrudes from the outside edges. Apply a bead of M-1 around the outside base of the installed E -Curb, and tool to form a smooth fillet. For non E -Curb penetrations seals, add M-1 to scarf joint surfaces and tool smooth. Step 4 Cut tip off 1 -Part cartridge at widest point on plastic nozzle and pierce the foil seal. Insert into caulking gun and pump E -Curb full. When using a 1 -Part pouch, remove cap, pour, squeeze out excess air, and reseal. Note: To provide an adequate rubber seal, maintain a 1" distance between penetrations and inside edge of the E -Curb. All properties described in this document are derived from testing conducted in laboratory conditions. Properties and performance will vary depending on environmental conditions and application technique. Test and evaluate to determine appropriate usage. Visit www.chemlink.com for the Material Safety Data Sheet, Technical Data Guides and full warranty for this product. LIMITED WARRANTY: CHEM LINK Products, LLC warrants this product's performance, provided it is properly stored and applied within 1 year. If not satisfied, return remaining product and purchase receipt for refund or replacement of product exclusive of labor or cost of labor. This is the sole and exclusive remedy for defects or failure of this product. User must read and follow the direction of the current Technical Data Guide and MSDS prior to product use. User determines suitability of product for intended use and assumes all risks. Manufacturer shall not be liable for damages (including consequential or incidental damages) in excess of the purchase price, except where such exclusion or limitation is prohibited by state law. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, WRITTEN OR ORAL, STATUTORY, EXPRESS OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE; except for the above express warranty given by manufacturer, the product is sold with all faults. CHEM LINK PRODUCTS, LLC SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS. This warranty gives you specific legal rights, and you may also have other rights in the U.S. which vary from state to state. For warranty claim information, call 800-826-1681. '0129NATKNAL � ASSOCIATION CHEm UNKQm ° MEMBER Advanced Architectural Products INSTITUTE 6661.2008;CLW /��-�,,�,�.p,�_ t W�4.W a ' Report No: 101541132LAX-002 Page 2 of 86 Issued: 22 -May -2014 ' CLASSIFICATION • IronRidge, Inc. Revised: 15 -Jan -2016•.. Constructional Data Report (CDR), 1 O Reference!and Address', Tr Re ort Number 101541132LAX-002 Original 22 -Ma -2014 JI Revised: 15 -Jan -2016 Brand name s': UL Subject 2703 Outline of Investigation for Rack Mounting Systems and Clamping Devices Standard(s) Al ,Applicant IronRidge, Inc. t IronRidge, Inc. ' Address, ' a ' Report No: 101541132LAX-002 Page 2 of 86 Issued: 22 -May -2014 ' CLASSIFICATION • IronRidge, Inc. Revised: 15 -Jan -2016•.. Constructional Data Report (CDR), 1 O Reference!and Address', Tr Re ort Number 101541132LAX-002 Original 22 -Ma -2014 JI Revised: 15 -Jan -2016 Brand name s': UL Subject 2703 Outline of Investigation for Rack Mounting Systems and Clamping Devices Standard(s) for Flat -Plate Photovoltaic Modules and Panels, Issue Number: 1, October 4, 2010 • ,Applicant IronRidge, Inc. ;Manufacturer 1 IronRidge, Inc. ' Address, ' 1495 Zephyr Ave Address 1495 Zephyr Ave . - , Hayward, CA 94544, Hayward, CA 94544 +, 'Count USA _Country`,_ USA xC,ontact Yann Schwarz `Jim `Contact Norsworthy Or ryDave .� n. Taggart' ' --i4 •i Phone',_--, (800) 227-9523 - -'° (707) 363-3025 ' Descriptionz ,. `; (510) 225-0973 .Phone i.F= (800) 227-9523 (707) 459-1833_ •, FAX, ` (510) 225-0975 -.-Eail ` r' � m vschwarzOironridge.corr "r a r, •Email - Inorsworthy(a_)ironridge. com ' national electrical codes. An entire array, regardless of size, is grounded via one grounding - o -- dtaggart@ironridge.com Manufacturer2. Precision Die 8r Stamping, Inc. ' ^ Address 1704 W. 10th Street .. r : Tempe, AZ 85281 M - , , ,• `• , • . r - s Country:.,- USA .:_Contact.:* Andy Frola • t Rhone', (480) 967-2038 FAX ".. (480) 829-0838 '", -:Email andv angrecisiondie.com _ iption � ` ' y• � • •` - . � w_ _ �I --4- 2.0 `Product!Descr� Product' f: ;'' i XR Rails with Integrated Grounding. - Brand name s': IronRidge Roof Mount *; The product covered by this report is the IronRidge Rails with Integrated Grounding solar roof •Y: mounting system. This system is designed to provide bonding and grounding to photovoltaic modules. The mounting system employs anodized aluminum rails that are roof mounted using 7 • v aluminum Extruded L foot brackets. The mounting rails in this report are XRL, XR10, XR100 ' r a. arid XR1000 Rail. All rails have an optional aluminum splice which ties the rails together to extend theiriength. + A grounding strap and stainless steel hardware are required for penetrating the anodized „r coating of the rails, creating a bonded connection from rail to rail. 304 stainless steel Grounding *; Mid Clamp and aluminum End Clamps are used to attach and support framed photovoltaic , modules to the system: The End Clamps are not used as a grounding means. The Grounding Mid Clamps are installed onto the module frame by using a 18-8 stainless steel serrated T -Bolt and a 18-8 stainless steel Flange Hex Nut that gets screwed onto the rails to a Descriptionz ,. `; specified torque. The retention teeth of the clamp and bolt penetrate the anodized coating of -' the photovoltaic modules frame and rail to contact the metal, creating a bonded connection `- from module to'module and module to rail. " The grounding of the entire system is intended to be in accordance with the'latest edition of the • National Electrical Code, including. NEC 250: Grounding and Bonding, and NEC 690: Solar Photovoltaic Systems. Any local electrical codes must be adhered in addition tathe - ' national electrical codes. An entire array, regardless of size, is grounded via one grounding Iug.,The WEEB Grounding Lug is secured to XRL, XR10, XR100 or XR1000 Rail's top slot using stainless steel hex bolt or T -Bolt, flat washer, split lock washer, and nut, tightened to ° ^� manufacture's specified torque. The WEEB Grounding Lug is intended for use with one solid or stranded copper wire, Conductor size 14 AWG though 6 AWG. The Titan Grounding Lug is secured to XRL, XR10, XR100 or XR1000 Rail's side center cavity of rails using stainless steel, T -bolt, k -lock nut, star washer, and machine screw. -The Titan Grounding Lug is intended for use with one solid or. stranded copper wire, conductor size 14 AWG though 4 AWG. Models IR XR followed by 4 Alphanumeric Characters' ..Model. Similarity, N/A 41 Fuse Rating: 20 A , ' Fire Class Resistance Rating: - c - Class A for Steep Slope Flush -Mount (Symmetrical) Applications when using Type 1, ' - Type 2 and Type 3, Listed Photovoltaic Yodule. , - Class A for Low Slope Flush -Mount (Symmetrical) Applications when using Type 1, Ratings ` . Type 2 and Type 3, Listed Photovoltaic Module. ' - Class A for Steep Slope Tilt -Mount (Asymmetrical) Applications when using Type 1 and Type 2, Listed Photovoltaic Module. " J7 - Class A for Low Slope Tilt -Mount ( Asymmetrical) Applications when using Type 1, a Type 2 and Type 3, Listed Photovoltaic'Module. . r Page 1 of 86 • + ,This.report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between InterteK,and its Client. Intertek's responsibility and , k liability,are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the Y • : > . - t agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and • . t ■ then only in its entirety. 'Any use of the Intertek name or one of its marks for Ute sale or advertisement of the tested material, product or service must first be , - approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the +' ' • • -material, product, or service is or has ever been under an Intertek certification program. r ' -, .. x r i - �'• - >N ' • F v _ ' 3 ED 16.3.15 (1-Jan-13)Mandatory - . r r 7 • v + 1 r Page 1 of 86 • + ,This.report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between InterteK,and its Client. Intertek's responsibility and , k liability,are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the Y • : > . - t agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and • . t ■ then only in its entirety. 'Any use of the Intertek name or one of its marks for Ute sale or advertisement of the tested material, product or service must first be , - approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the +' ' • • -material, product, or service is or has ever been under an Intertek certification program. r ' -, .. x r i - �'• - >N ' • F v _ ' 3 ED 16.3.15 (1-Jan-13)Mandatory - . 25800 Commercentre Drive Lake Forest, CA 92630 USA Telephone: 949.448.4100 Facsimile: 949.448.4111 www.intertek.com Test Verification of Conformity In the;basis of the tests undertaken the samples) of the below product have been.found to,comply with,the requirements of the referenced specifications at the time the tests .were, carried out. , This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, -product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. GFT -OP -11a (24 -MAR -2014) Applicant Name &Address:' IronRidge, Inc.'r - _ _ 1495 Zephyr:Ave: • Hayward, CA 94544 •, M �. Jam{ - - • • a"i .. . L V -LF � � r. M , 1. i �. •. \lila .. Prod uct'.Description:} .. i"•. - 1a L' r r .. ,. .,_' t ,XR Rails with Integrated'Grounding i 4 _ 'Ratings & Principle: Fire Class Resistance Rating: r' r� i Characteristics— Cl forJSteep Slope'FlushMotant (symmetrical) Applications hen. using Type 1 and -" ' , ". Type,2,�Listed' Photovoltaic Module. ' t i:4 y ` • K: Class Alfor Low Slope Flush=Mount andrTilt-lVlount�(symmetrical and asymrnetrical)y ; Applications when using Type 1; Listed Photovoltaic Module. Models:' ' ,51 61GD-005,,51-61GD 005$, 51=5000-001,_.and 51-65-001., Brand Name:' ,� Nq .: »Relevant Standards:.. UL Subject 2703„(Section 15.2 and,15'.3YOutline of Investigation for Rack Mounting Systems and Clamping Devices. for.F..IatyPlate1Photovoltaic Modules and Panels, Issue Number: 2, Nov 13; 2012 ' .. . Rderencing•UL1703 (Section 31':2) Standard for -Safety foriFlat-Plate Photovoltaic Module's'and :Y Panels, IVlay`20,�2014` �s , • J j . <` .u• - ' Intertek Testing Serviees,NA, Inc..7 Verification'rlssuing,Office. 25800 CornmercentreMDr. Lake, Forest, JCA,92630 Date'of 08/27/2014 to 01/07/21015 ❑ y ' _. _ ;Test Report°Number(s): - .F f 101541132LAX=002 w * • , This verification is'part:of the full test reports) and s6ould'be read,in,con'unction witF them. -This report does.not automaticall Y p .imply product certification .. _ ^, r -` a •, � � Completed by -”Amar Kacel ry Andew.K retofReviewed by: o '• ` Title ` *'" ,•FV Engineer° F ° 'Title 'Reviewer .. Signature Signature. g . , K • . s , �� � qt ' . „-� , YAM v _ r .. .. " . e - • Date: 01/26/2015 >_ Date:, 01%26/2015 , , This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, -product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. GFT -OP -11a (24 -MAR -2014) Carbon monoxide alarms required by Sections R315.1 and R315.2 shall be installed in the following locations: 1. Outside of each separate dwelling unit sleeping area in the immediate vicinity of the bedroom(s). 2. On every level of a dwelling unit including basements. R315.1.5 Multiple -purpose alarms: Carbon monoxide alarms combined with smoke alarms shall comply with Section R315, all applicable standards, and requirements for ,lis ting,and approval by the Office of the State Fire Marshal, for smoke alarms. Butte County's Interpretation of 2016 CRC, Sections 314 & 315 -for Smoke Alarms & Carbon Monoxide Alarms: Where alterations, repairs or additions exceeding $1,000 in valuation, existing dwellings shall be retrofitted with smoke alarms and those that have attached_ garages or fuel -burning appliances shall have carbon monoxide alarms installed. Existing smoke alarms can be replaced with dual function alarms for Smoke and Carbon Monoxide and in most cases will comply with the aforementioned code requirements for Carbon Monoxide Alarms. DECLARATION OF INSTALLATION UNDER THE PENALTY OF PERJURY As Owner/Contractor, I/we affirm and declare under the penalty of perjury, under the laws of.the State of California, by our signatures below as Owner/Contractor, that I/we will comply prior to final inspection with Items A & B as specified herein: A. Both Owner/Contractor have read and clearly understand the aforementioned 2016 California Residential Code (CRC) Carbon Monoxide Alarm requirements. B. Both Owner/Contractor are responsible for installing. Carbon Monoxide Alarms prior to final inspection as per the aforementioned building code and maintaining such installation. Smoke Alarms will also be installed prior to final inspection as per the 2016 CRC. Smoke and Carbon Monoxide alarms are now installed in the following locations: Owner's name (print): Owner's signature: � - --z ens.e:_r1?Z �179z Contractor's signature: - Date:/-//— Project Address: 4/? y�0o 1*2�. �., , 0 `�5`l/s Permit #: Page 2 of 2 Revised 12.19.2016 Butte County Department of Development Services PERMIT CENTER 7 County Center Drive, Oroville, CA 95965 Malin Phone (530) 538-7601 Fax (530) 538-7785 a w%v.hnuccounlv.nci/dds Declaration of Installation for Smoke Alarms and Carbon Monoxide Alarms FORM NO DBI -01 The newly adopted 2016 California Residential Code requires the installation of Carbon Monoxide Detectors in dwelling units and in sleeping units within which fuel -burning appliances are installed and in dwelling units that have attached garages. The policy for Carbon Monoxide Alarms in Butte County states: "Any permit obtained in which the value of work exceeds. $1000 associated with a Residential Group R Dwelling Unit or Sleeping Unit shall conform to the following 2016 California Residential Code requirements for Smoke and Carbon Monoxide Alarms (Section R314 & R315)." 2016 California Residential Code requirements for Carbon Monoxide Alarms: R315.1 New construction: An approved carbon monoxide alarm shall be installed in dwelling units and in sleeping units within which fuel -burning appliances are installed and in dwelling units that have attached garages. R315.1.2 Power supply: For new construction required carbon monoxide alarms shall receive their primary power from the building wiring where such wiring is served from a commercial source and shall be equipped with a battery back-up. Alarm wiring shall be directly connected to the permanent building wiring without a disconnecting switch other than as required for over - current protection. Exceptions: I. In dwelling units where there is no commercial power supply the carbon monoxide alarm may be solely battery operated. 2. In existing dwelling units a carbon monoxide alarm is permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. R315.1.3 Interconnection. Where more than one carbon monoxide alarm is required to be installed within the dwelling unit or within a sleeping unit the alarm shall be interconnected in a manner that activation of one alarm shall activate all of the alarms in the individual unit. Exception: 1. Interconnection is not required in existing dwelling units where repairs do not result in the removal of wall and ceiling finishes. there is no access by means of attic, basement or crawl space, and no previous method for interconnection existed. R315.2 Where required in existing dwellings: Where a permit is required for alterations, repairs or additions exceeding one thousand dollars ($1,000), existing dwellings or sleeping - - - --- ---units-that-have-attached-garages-or-fuei:burning-appliances-shall-be provided -with -a -carbon monoxide alarm in accordance with Section R315.1. Carbon monoxide alarms shall only be required in the specific dwelling unit or sleeping unit for which the permit was obtained. R315.2.6 Alarm requirements: No person shall install, market, distribute, offer for sale or sell any carbon monoxide device in the State of California unless the device and instructions have been approved and listed by the State Fire Marshal. Page 1 of 2 Revised 12.19.2016