Loading...
HomeMy WebLinkAboutB17-2990 039-100-023�t r• BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspections is 3pm) Development Services cannot guarantee inspections on the date requested of4FrP ;io ;ii 7#;M Fav• sin siR 77R4 � RuttPCnnnty nethirk Permit No: B17-2990 Issued: 12/19/2017 APN: 039-100-023 Address: 790 LIBERTY LN, CHICO Owner: COSTELLO DARRELL M & JOHNSON Permit Type: SOLAR ROOF -RES Description: SOLAR ROOF - RES (8.16KW) AREA Flood Zone: SRA Area: SETBACKS for Zoning. AG. SRA. PW_ Front: Centerline of Road: Rear: SRA: Street: AG: Interior Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING ,f Ins ection Type IVR INSP DATE Setbacks 131 Foundations / Footings 111 Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Signed Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 Blockin nde irin 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or'Slab Until Above Signed ShearwallB.W.P.-Interior 134 ShearwallB.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 417 Manometer Test Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed Permit Final 802 Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test or Final 702 Swimming Pools Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Swimming Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 503 Pre -Plaster , 507 Manufactured Homes Setbacks 131 Blockin nde irin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Skirtin Ste s/Landin s 610 Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: Length x Width: Insignia: Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final "PROJECT FINAL I yrf lwa// I -rroject rmai is a %-ernncate of occupancy mr tmesmentim vinyl PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF NSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION ,� �� 4 a � . i i l � 4. ,� S «. f .. .. ,♦ r i ' �i {� �� I { ,� �� 4 a � . 4 a � . i i l � BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT 24 HOUR INSPECTION (IVR)#:530.538.4365 OFFICE #: 530.538.7601 FAX#:530.538.7785 www.ButteCounty.net/dds PROJECT INFORMATION Site Address: 790 LIBERTY LN Owner: APN: • 039-100-023 COSTELLO DARRELL M & JO Permit type: MISCELLANEOUS 790 LIBERTY LANE Subtype: SOLAR ROOF -RES CHICO, CA 95928 6escrintinn Cni.AR ROOF - RFC IRA 6KW1 ,y ­-- Permit No: B 17-2990 Is3ued Date: 12/19/2017 By JMD Expiration Date: 12/19/2018 Occupancy: Zoning: Contractor P Y Applicant: Square Footage: ' RUSSELL T MARKS RUSSELL T MARKS Building Garage Remdl/Addn 1632 GARDEN ROAD 1632 GARDEN ROAD 0 0 0 DURHAM., CA_ 95938 DURHAM, CA 95938 Other Porch/Patio Total 1 5306807331 5306807331 0 0 0 LICENSED CONTRACTOR'S DECLARATION • ' i OWNER I BUILDER DECLARATION _ .. Contractor (Name) " State Contractors License No. I Class I Expires 'I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for RUSSELL T MARKS 701317 / C46 / 8/31/2018 the reason(s) indicated below by the checkmark(s) I have placed next to the applicable item(s) (Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the authorization form I HEREBY AFFIRM UNDER PENALTY OF PERJURY that I am licensed under provisions of Chapter 9 Permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' (commenting with Section 7000) of Division 3 of the Business and Professions Code, and my license i Slate License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and in full force and effect. Professions Code) or that he or she is exempt from licensure and the basis for the alleged exemption. X Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): 1:1I, as owner of the property, or my employees with wages as their sole compensation, will Contractor's Signature Date do U all of or L) portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the I Property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the WORKERS', COMPENSATION DECLARATION _, . ' ' I HEREBY AFFIRM UNDER PENALTY OF PERJURY one of the following deciarations: I I cI have and will maintain a certificate of consent to self -Insure for workers' I I on ensation Issued I the Director of Industrial Relations as provided for by Section burden of proving that it was not built or improved for the purpose of sale.). 3700 of the Labor Code, for the performance of the work for which this permit is issued. Policy i No. I have and 01 maintaln workers' compensation Insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: r • r Cartier. FXFMPT Policy Number. Exp. Date: t I certify that, In the performance of the work for which this permit is Issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that. if I should become subject to the workers' com ensation rovisions of Section 3700 of the Labor Code I shall forthwith comply with those I, as owner of the property, am exclusively contracting with licensed Contractors to construct the project (Section 7044, Business and Professions Code: The Contractors' Slate ' License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a licensed Contractor pursuant to the Contractors' State License Law.). ❑I am exempt from licensure under the Contractors' State License Law for the following reason: P P provisions. Owners Signature Date XPERMITFAPPLICANT DECLARATION,: - 71,771 yBy Signature Date my signature below, I certify to each of the following: ' WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS I am U a California licensed contractor or U the property owner' or U authorized to ct the property owner's behalf**. UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES he read this construction permit application and the information I have provided is, I have AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN correct. ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN t agree to comply with all applicable city and county ordinances and state laws relating SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. to building construction. 1 authorize representatives of this city or county to enter the above -identified property CONSTRUCTION LENDING AGENCY DECLARATION' :. for inspection purposes. California Licensed Contractor, Property Owner' or ' Authorized Agent": 'requires separate verification form "requires separate I hereby affirm under penalty of perjury that there is a construction lending agency for the authorization form performance of the work for which this permit is issued (Section 3097, Civil Code). ' Lender's Name and Address X " ame of Permittee [SIGN] Print • Date Lenders Name & Address City State Zip FEE INFORMATION Total Fees: $511.00 Fees Paid: $511.00 Balance Due: (None) Job Value: $22,940.00 4• i r Carbon monoxide alarms required by Sections R315.1 and R315.2 shall be installed in the following locations: 1. Outside of each separate dwelling unit sleeping area in the immediate vicinity of the bedroom(s). 2. On every level of a dwelling unit including basements. R315.1.5 Multiple -purpose alarms: Carbon monoxide alarms combined with smoke alarms shall comply with Section R315, all applicable standards, and requirements for listing and approval by the Office of the State Fire Marshal, for smoke alarms. Butte County's Interpretation of 2013 CRC, Sections 314 & 315 for Smoke Alarms & Carbon Monoxide Alarms: Where alterations, repairs or additions exceeding $1,000 in valuation, existing dwellings shall be retrofitted with smoke alarms and those that have attached garages or fuel -burning appliances shall have carbon monoxide alarms installed. Existing smoke alarms can be replaced with dual function alarms for Smoke and Carbon Monoxide and in most cases will comply with the aforementioned code requirements for Carbon Monoxide Alarms. DECLARATION OF INSTALLATION UNDER THE PENALTY OF PERJURY As Owner/Contractor, I/we affirm and declare under the penalty of perjury, under the laws of the State of California, by our signatures below as Owner/Contractor, that I/we will comply prior to final inspection with Items A & B as specified herein: A. Both Owner/Contractor have read and clearly understand the aforementioned 2010 California Residential Code (CRC) Carbon Monoxide Alarm requirements. B. Both Owner/Contractor are responsible for installing Carbon Monoxide Alarms prior to final inspection as per the aforementioned building code and maintaining such installation. Smoke Alarms will also be installed prior to final inspection as per the 2010 CRC. Smoke and Carbon Monoxide alarms are now installed in the following locations: Smoke/Carbon Monoxide Combination alarms located in Kitchen, & Hallway. Smoke detector in each of the three bedrooms Owner's name (print): _,, dele Owner's signature: December 18, 2017• Contractor's name (print): Russ(cs CSLB License: 701317 Contractor's signature: Date:December 18, 2017 Project Address: 790 Liberty Lane, Chico, CA 95928 Permit #: -,,.2Ci Page 2 of 2 Revised 7.20.2.015 � • . � � O • • • ~Y" �1 "� ,_�'=.7, • ,�4,h .}1 II. I. rI f.11`"•tA �l.'�'� � 7���%�,",'�•�''" . iii � • ,�,:� ��i4 !t}T�l��,- Y � 7,•y t ,j/!,�!,�� "i� � 555 r� �►',• ''�':�,, I ww w w . Q(�,i 1 \ ��" • I .� r l �� of •i •�,, � `5 ,r79u Llibeiy,Ln 1 ►, ! : ((( 4:"it `111 ti.. 1 Tk U Lei is] '•. Soli•' -'`rq� •>�'' ' {5.�2� e"�, �lyi ', i�� y,t''��•, ,vY � ' 'iii • 4 h'1� � '^ �.{,7 � 'j'%`- �� Company'Information: 40 Of °ate/ t - -� a • ' � 7• / - ., ' - •« %' - _ ' `_ _ .-, .. PROJECT SITE t c0- , U -0O c6 M NT O i LL- C Lo co )"Vo (co - / 0 MAIN N L cu co HOUSE _j /J - - • _. PRO's,\` PERTYCIN ��, - ,� 2 / m - , t _ -EXISTING DRIVE WAY ,� a I 4700WbortyLane - (24) CANADIAN / SOLAR CS61J-340M • v ROOF #1 1 ` SITE PLAN WITH ROOF PLAN 3 VICINITY MAP PV -1 SCALE: 1/30" = 1'-0" PV -1 ' SCALE: NTS , Company'Information: r r O , U -0O c6 M NT O i LL- C Lo co )"Vo (co i N L cu co _j PROJECT NAME & ADDRESS COSTELLO JOHNSON 790 LIBERTY LANE, CHICO, CA 95928, USA PHONE NO: XXX-XXX-XXXX APN NO:039-100-023 Y � `' " DATE: 12/18/2017. SHEET NAME SITE PLAN & VICINITY MAP. SHEET NUMBER PV -1 MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = 24 MODULES MODULE TYPE = CANADIAN SOLAR CS6U-340M MODULE WEIGHT = 49.4 LBS / 22.4 KG. MODULE DIMENSIONS = 77.2"x 39.1" = 20.67 SF UNIT WEIGHT OF ARRAY = 2.35 PSF ARRAY & ROOF -AREA /C` I IT11 ITV METER ,IN SERVICE PANEL 4C DISCONNECT I) INVERTER Company Information: CALC'S (ROOF #1) ARRAY AREA = 492.54 SQ. FT. O O i ROOF FACE AREA =876.40 SQ. FT. 492.54/876.40 = 56.20% OF ROOF FACE AREA COVERED BY ARRAY / ROOF DESCRIPTION / ROOF TYPE - COMP I� ROOF TILT - 18° i r -ROOF AZIMUTH - 270° i M RAFTER SIZE - 2x4" @ 24" O.C. r 0 (E). BACKYARD U 0 M L o czc:MM j MC4 D/C CABLE ARMORED O ) Q U co ®ROO'OOF / (13 # / .g2,MTl�T_ , M Igo (a N i J icz FRONTYARD T :3 (E) ~ (90) PV ATTACHMENT @ 24" o.c. (N) SWH SOLAR MOUNT RACKING SYSTEM (24) CANA SOLAR CS6U- 1 ROOF PLAN & MODULES PV -2 SCALE: 3/32" = V-0" 39.1 CANADIAN cN SOLAR rl- CS6U-340M LEGEND UM - UTILITY METER O ❑ VENT, ATTIC FAN (ROOF OBSTRUCTION) CNV -INVERTER O ROOF ATTACHMENT DC INTEGRATED DC DISCONNECT -RAFTERS PM - PRODUCTION METER ----- - CONDUIT MSP - MAIN SERVICE PANEL ACD - AC DISCONNECT PROJECT NAME.& ADDRESS COSTELLO JOHNSON 790 LIBERTY LANE, CHICO, CA 95928, USA PHONE NO: XXX-XXX-XXXX APN NO:039-100-023 DATE: 12/18/2017 SHEET NAME ROOF PLAN & MODULES SHEET NUMBER PV -2 -3 + + + + + + + + SOLAR ARRAY (8.160 kW -DC STC) TOTAL SOLAR STRING #1 (2.72 kW -DC STC) (8) CANADIAN 340M SOLAR MODULES (8) MODULES CONNECTED IN BRANCH CIRCUIT r—1 1 r-1 r —1 + + + + + + + + SOLAR ARRAY (8.160 kW -DC STC) TOTAL SOLAR STRING #2 (2.72 kW -DC STC) (8) CANADIAN 340M SOLAR MODULES (8) MODULES CONNECTED IN BRANCH CIRCUIT r---- - - - - - - - + + + + + + + + SOLAR ARRAY (8.160 kW -DC STC) TOTAL SOLAR STRING #3 (2.72 kW -DC STC) (8) CANADIAN 340M SOLAR MODULES (8) MODULES CONNECTED IN BRANCH CIRCUIT (6) #12 MC4 D/C CABLE ARMORED (3) #12 AWG THWN-2 GND IN 3/4" EMT I FRONIUS PRIMO 8.2-1 KW 240VAC DC = TERMINAL BLOCK L1 L2 N MPPT1 MPPT2 DC = DISCONNECT GROUNDING TERMINAL GROUNDING ELECTRODE TERMINAL' ELECTRICAL LINE DIAGRAM SCALE:NTS z Company Information: ELECTRICAL NOTES: 1. CONTRACTOR RESPONSIBLE FOR COMPLYING WITH ALL LOCAL &NEC CODE REQUIREMENTS AND MANUALS FOR INSTALL A PV SYSTEM. 2. ALL COMPONENTS MUST BE GROUNDED PER NEC REQUIREMENTS. 3. EACH MODULE MUST BE GROUNDED ACCORDING TO INSTALLATION REQUIREMENTS. 4. ALL EQUIPMENT SHALL BE LISTED PER NEC. 5. PER NEC 690.7, PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN OPEN POSITION. SIGN SHALL READ "WARNING SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINES AND LOAD SIDE MAY BE ENERGIZED IN OPEN POSITION OR EQUIVALENT". 6. PER NEC 705. O, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES. 7. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 690.64. 8. A/C AND/OR D/C DISCONNECT MAY OR MAY NOT REQUIRED BY THE AHJ (AUTHORITY HAVING JURISDICTION). 9. WIRE SIZE ASSUMES THAT CONDUIT WILL BE RUN IN ATTIC SPACE OR LESS THAN 10' IS EXPOSED TO SUNLIGHT PER NEC 310.15(A)(2)Ex. WIRE GAUGE MAY NEED TO BE INCREASED IF RUN IN CONDUIT ON THE ROOF FOR MORE THAN 10' PER NEC 310.15(B)(3)(C). 10. DO NOT ATTACH ANY HARDWARE ON TOP OF RAIL DIRECTLY UNDER SOLAR MODULE. DOING SO MAY VOID MODULE WARRANTY. T 11. INSTALL INVERTER PER MANUFACTURERS DIRECTIONS. M T o U cz M 0 iO M Lo 01 ( c:Cy) 0 (0 - 6 cd cn LP cz N i J BI-DIRECTIONAL AC DISCONNECT: . UTILITY METER 240V, 200A/2P, FUSED 40A 1 -PHASE, 240 V NEMA 3R, UL LISTED 40A (E) MAIN SERVICE PANEL, 1 -PH, 3-W, 200A RATED, 240V, 2P. PG&E AND SMART METER I coN T N 17.7 (E) MAIN BREAKER TO HOUSE 240 V,200A (3) #6 AWG THWN-2 (1) #6 AWG THWN-2 GND IN %" EMT 40A/2 P (3) #6 AWG THWN-2 (1) #6 AWG THWN-2 GND IN 3/4" EMT 6' APPROX J :EXISTING GROUNDING ELECTRODE SYSTEM PROJECT NAME & ADDRESS COSTELLO JOHNSON 790 LIBERTY LANE, CHICO, CA 95928, USA PHONE NO: XXX-XXX-XXXX APN NO:039-100-023 DATE: 12/18/2017 SHEET NAME ELECTRICAL LINE DIAGRAM SHEET NUMBER PV -3 7r, ELECTRIC SHOCK HAZARD' IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED LABEL LOCATION: _ DC DISCONNECT, INVERTER r "(PER CODE: NEC 690.35(F)) . '[To be used when inverter is ungrounded] RELOCATE THIS OVERCURRENT DEVICE a r _ _ • f. '' LABEL LOCATION: ELECTRIC SHOCK HAZARD POINT OF INTERCONNECTION ' THE DC CONDUCTORS OF THIS (PER CODE: NEC 705.12(D)(7)) PHOTOVOLTAIC SYSTEM ARE UNGROUNDED [Not required if panelboard is rated not less than sum of ampere ratings of all overcurrent devices supplying it] AND MAY BE ENERGIZED • _ _71T * LABEL LOCATION: - � CAUTION: • AR CIRCUIT r , '~- .. - `r,• ., • ` ` T - DC DISCONNECT, INVERTER R O (PER CODE: NEC 690.35(F)) LABEL LOCATION: " ` [To be used when inverter is ungrounded] MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES, ; _ V 0 r LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION I • ' (PER CODE: NEC690.54) AND CABLE ASSEMBLIES AT LEAST EVERY 10 FT, AT TURNS AND ABOVE/BELOW PENETRATIONS O M " AND ALL COMBINERMUCTION BOXES. (PER CODE: IFC605.11.1.4) ' °` • J j J Oi (j) CZ C (M CO SOLAR DISCONNECT .O a)< LABEL LOCATION: *`; - CU DISCONNECT, POINT OF INTERCONNECTION _ w (PER CODE: NEC690.13(B)) ccu N • ' CZ • S LABEL LOCATION:' AC DISCONNECT, POINT OF INTERCONNECTION LABEL LOCATION: t f (PER CODE: NEC 690.17(E)) POINT OF INTERCONNECTION (PER CODE: CEC 705.12(D)(4)) AC DISCONNECT, POINT OF INTERCONNECTION r PER CODE: NEC 690.17(E), CB CAUTION:• PROJECT NAME &ADDRESS SYSTEM CONNECTED - i LABEL LOCATION: COSTELLO JOHNSON' POINT OF INTERCONNECTION ' - N 790 LIBERTY LANE, (PER CODE: CEC690.15, 690.13(B)) 4; iCHICO, CA 95928, USA ` ' K PHONE NO: XXX-XXX-XXXX L A - APN NO:039-100-023 f + • LABEL LOCATION: INVERTER, JUNCTION BOXES (ROOF), AC DISCONNECT (PER CODE: NEC690.13.G.3 & NEC 690.13.G.4) PHOTOVOLTAIC POWER• LABEL LOCATION: ` + CONDUIT, COMBINER BOX (PER CODE: NEC690.31(G)(3)(4) & NEC 690.13(G)(4) ADHESIVE FASTENED SIGNS: . THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT ` WHERE IT IS INSTALLED. - • WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD ; APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING]. • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF = PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER ' RESISTANT [IFC 605.11.1.3] � • r 1 ATTACHMENT DETAIL PV -6 SCALE: 1" = V-0" SEE (2/P FOR ENLARI V PV MODULE FLASHING, 12"x12"x0.050", . 5050, MILL 2 ATTACHMENT DETAIL (enlarged view) PV -6 SCALE: NTS GROUNDING END/MID CLAMP SWH RACKING ALUMN. "L" BRACKET W/3/8" SS BOLT & NUT (E) COMPOSITE SHINGLE ROOF 5/16"x3" SS LAG BOLT WITH MIN 2%" THREAD EMBEDMENT, SEALED PENETRATION 2"x4" RAFTERS @ 24" OC Company Information: DATE: 12/18/2017 SHEET NAME ATTACHMENT DETAIL SHEET NUMBER PV -5 T co T 0 U cz M 0 O 0) (r Lo i cz c 0) Ch � 70 U o cO (D cz iN -r— J CZ cf) T PROJECT NAME & ADDRESS COSTELLO JOHNSON 790 LIBERTY LANE, CHICO, CA 95928, USA PHONE NO: XXX-XXX-XXXX APN NO:039-100-023 DATE: 12/18/2017 SHEET NAME ATTACHMENT DETAIL SHEET NUMBER PV -5 `Company Information: �� �� - \'. %�9A 1I y_ A ~• ria _ . 1. _ „ � ,( � •• � i � . w f i •- .. ... - • r - �•' 1, - W;� %'rid " . e'' ' ENGINEERING DRAWING(mm)CS6U-335M / I-V CURVES ' ._1'*�,• �.� �r CanadianSolar, r q A ` 4 y . • Rear View Frame Cross Section A -A 10 _� __ 10 -_ ` qty r3 c ♦.. _ - k:. 1tk1_ - e ' Al r4. lei 6 .. +.•` � u � 9 �� }•. r f J^ ' . r _ j - _ _ � � a.10,] .- � 1 5 "-.- _ � '-_ 5. • f :#r• v � DC �• l swr ^ it::� ,. _ ^. Mwnl'n9 1 , __ ._- 6_ !.� t r• •+ C �. :. I1 - 1 , tni0dle sor ' 3 '•--•---•--�-- -- ' - _. y n Mounting Hole ;-- ., - _ 3 ��. t •� 5 10 15 20 25 30 35 <0 a5 50 5 10 15 20 25 30 35 40 45 50 \' M + AMwQntIM - A A N°i4 I(. 12845 °laoowim' s•C MAXPOWER = ` r i Coe°d � r ; 'rr, ° 900 Win: 25` ° • o ^O . ° 600 W/rrP 45`G ° O ` ` ( ° 400 w]m+, 65•c ° . ti = CS6U-32513301335 1340M s : .-a E-12 o c°(11f L0 .� .. rn ELECTRICAL DATA I STC*, MECHANICAL DATA,. L t Canadian Solars modules use the latest innovative : - C56U 325M.- 330M 335M 340M Specification Data cell technology, increasing module power output and % Nominal Max. Power (Pmax) 325 W 330 W 335 W 340 W Cell Type Mono -crystalline, 6 inch O 0 U � system reliability, ensured by 15 years of experience =- Opt Operating Voltage (Vmp) 37.4 V 37.5 V 37.8 V 37.9 V Cell Arrangement 72 (6x 12) '^ O inmodulemanufacturing, well -engineered module _ r.R `•S3 -Opt Operating Current (Imp) 8.69A 8.80A 8.87A 8.97A Dimensions 1960x992x4Omm(77.2x39.1x1.57in) vJ (13 design, stringent BOM quality testing, an automated r s t, .Fr Open Circuit Voltage (Voc) 45.8 V 45.9 V 46.1 V 46.2 V Weight 22.4 kg (49.4 lbs) (n E CO manufacturing process and 100% EL testing. r ca LP Short Circuit Current (Isc) 9.21 A 9.31 A 9.41 A 9.48 A Front Cover 3.2 mm tempered glass L N L 25 1 A Module Efficiency 16.72% 16.97% 17.23% 17.49% Frame Material Anodized aluminium alloy L J linear power output warranty . _ (� years ..Operating Temperature, =40°C - +85°C J -Box IP67, 3 diodes - - �, w _ KEY FEATURES - Max. System Voltage • . 1000 V (IEC) or 1000 V (UL) Cable 4 mm2 (IEC)or4 mm2 & 12 AWG Q Module Fire Performance TYPE 1 (UL 1703) or 1000V (UL), 1160 mm(45.7 in) (�) product warranty on materials.CLASS C (IEC 61730) Connector T4 series or PV2 seriesExcellent module efficiency of and workmanship - Max. Series Fuse Rating 15A Per Pallet 26 pieces, 635 kg (1400 lbs) • up to 17.49 % , I Application Classification Class A Per container (49 HQ) 624 pieces .................. :...................................................................................................... .. - - J • i Power Tolerance '0 - + 5 W MANAGEMENT SYSTEM CERTIFICATES* L*Under Standard K Outstandinglow irradiance PROJECT NAME & ADDRESS ISO 9001:2008 Quality management system 1.5 and cell temperature of 25°C. ' O� Performance of up to 96.5% - ISO 14001:2004 / Standards for environmental management system - - - - ` .. • .. OHSAS 18001:2007 / International standards for occupational health & safety . ELECTRICAL DATA ( NOR* TEMPERATURE CHARACTERISTICS' COSTELLO JOHNSON t CS6U 325M 330M 3351VI 340M Specification Data 790 LIBERTY LANE, No.1 High PTC rating of up to 91.7 % PRODUCT CERTIFICATES* Nominal Max. Power (Pmax) 235 W 238 W • 242 W 245 W Temperature Coefficient (Pmax) _ _ -0.41 %/ °C CHICO, CA 95928, USA PTC IEC 61215 / IEC 61730: VDE / CE / CQC / MCS / INMETRO / CEC AU w Opt Operating Voltage (Vmp)' 34.1 V 34.2 V 34.5 V . 34.6 V Temperature Coefficient (Voc) -0.31 % / °C PHONE NO: XXX-XXX-XXXX ' UL 1703 / IEC 61215 performance: CEC listed (US) / FSEC (US Florida) Opt Operating Current (Imp) 6.88 A 6.96 A 7.01 A 7.10A Temperature Coefficient (Isc) 0.053 % / °C APN NO:039-100-023 UL 1703: CSA / IEC 61701 ED2: VDE / IEC 62716: VDE - + Open Circuit Voltage (Voc) , 42.0 V ` 42.1 V' 42.3 V 42.4 V Nominal Operating_ Cell Temperature _ 45t2 °C - IP67 junction box for long- UNI 9177 Reaction to Fire: Class 1 a Short Circuit Current (Isc) 7.46 A: 7.54 A 7.62 A 7.67 A 1x67 term weather endurance - . r IEC 60068.2.68: $G$ - _ "� • • Under Nominal Operating Cell Temperature (NOCT), Irradiance of Soo WIrn", " _ - ' Take=e-way _ spectrum AM 1.5, ambient temperature 20°C, wind speed 1 m/s. - •• y' _ - - _ ** Heavy snow load up to 5400 Pa, ; ^ - i -� PERFORMANCE AT LOW IRRADIANCE PARTNER SECTION C� wind load up to 2400 Pa. de lSA_' e 1 BBA✓ �'IcE"T (.................................................................................................. A'0vu6� �� O �t5 Outstanding performance at low irradiance, with an" """ - average relative efficiency of 96.5 %from irradiances, As there are different certification requirements in different markets, please contact ` your local Canadian Solar sales representative for the specific certificates applicable to r between 1000 W/m2 and 200 W/m2 (AM 1.5, 25°C): ~ w the products in the region in which the products are to be used. .. _ The specification and key features described in this datasheet may deviate slightly . and are not guaranteed. Due to ongoinginnovation,researchandprodu CANADIAN SOLAR INC. is Committed to providing high quality tt _ t -- - . ♦ ` - - +. - r enhancement, Canadian Solar Inc. reserves the right to make any adjustment - .. solar products, solar system Solutions and services t0 Customers to the information described herein at anytime without notice. Please always • o obtain the most recent version of the datasheet which shall be duty incorporated around the world. AS a leading PV project develper and • _ into the binding contract made by the parties governing all transactions related DATE: » manufacturer of solar modules with over 17 GW deployed around to the purchase and Sale of the products described herein. r ' the world since 2001, Canadian Solar Inc. (NASDAQ: CSIQ) is One of Caution: For professional use only. The installation and handling of PV modules 12/18/2017 it professional skills and should n performed qualified professional . . r a i the most bankable solar companies worldwide. ^ a Please r ad the safety and installation instructions before using the modules. -s_ ............................................................................................................ SHEET NAME CANADIAN SOLAR INC. - CANADIAN SOLAR INC. Jan.2017. All rights reserved, PV Module Product Datasheet V5.531 -EN . EQUIPMENT 545.Speedvale Avenue West, Guelph, Ontario N1 K 1 E6, Canada, www.canadiansolar.com, support@canadiansolar.com SPECIFICATION SHEET NUMBER I, Perfect Welding Solar Energy Perfect Charging SHIFTING THE LIMITS FROMOUS PRIM6 The future of residential solar is here - Introducing the now Fronius.Primo. �� • e�rmn liii� _`I PC v-, Air Nult ikit a- I rur ,,, _V7. �1 1p xlo�i With power categories ranging from 3.8 kW to 15.0 kw, the transformerless Fronius Primo is the ideal compact single-phase inverter for residential applications. The sleek design is equipped with the SnapINverier hinge mounting system which allows for lightweight, secure and convenient installation and service. The Fronius Primo has several integrated features that set it a -part from competitors including dual powerpoint trackers, high system -voltage, a wide input voltage range, Wi-Fi* and SunSpec­ Modbus interface for seamless monitoring and clatalogging, Arc Fault Circuit Interruption (AFCT), and Fronius' online and mobile platform Fronius Solar.web. The Fronius Primo is designed to adjust to future standards, offering a complete solution to code restrictions and technical innovations of tomorrow. It also works seamlessly with the Fronius Rapid Shutdown Box for a reliable NEC 2014 solution. TECHNICAL DATA FRONIUS PRIMO GENERAL DATA FRONIUS PRIMO 3.8 - 8.2' FRONIUS PRIMO 10.0-15.0 Dirn"eminus (width x height .&Iah) 16.9 a 24.7 x 8.1 in. 20.1 x 28.5., 8.9 in. L%A1eizfit­_ - -1 - 47.2916. 11- Ir - NEMA 4X Ni •bt Titre "'implign ZI <Iw i Inviter topology' Trinsfornierless fall Installation Indoor and cundri., in,tallaticn, Ambient 'emouraiture-f., g, Ai -40.131'F-10-_55'C __ - - it - - . - - liermittr.,l humidity 0_100% f -D(7 ZxuiinW, and 4x -�7'rl='.1.11,r-p-,A'df--ndedl-'4.DC,',2.D and 6. 0C. screw I "In."' Foc. Ii. stranded t� L_1_2 -suanded G4 stranded T e (wild !1 1, fin I AC-rineclion,,rimirtals S. ew terminals 12 - 6 AWG I. Revenue Grade Metering OptionallA3SIC12.1amirap9 j IlL 1741-2010, IIL1998 (fur (u nf,I Tun.;: AFCI and isolation U L 1741.2015, U1.1998 If.r F efion,: AFCI. RCN111 and isolation nuotfiluring), IEEE 1547-2003, IEEE 1547.1-2003. ANSIIIEEE monitoring), IEEE 1547-2003. ]FEE 1547.1-2003, ANSIJIEEE . Certifi­ and r..uplian,r, with standards C62.4 I -C ,',IF 1-1 15 A &- B,C A,,ide 690,C 21 22.No. 107.1-01 C62.4 1, FCC Pan 15 A & R, NEC Article 690-2014, C22. 2 IN,). ("elueu;,11 2001) , 11 L 1691) B Issue 2 .2013, CA TI 1. M -07 Issur. 1 107.1,01 (S,pleu,he, 2001), OL16991i 1 2.2013. CSA Tl I • .2013 M-07 I.ue 1 -2013 PROTECTIVE DEVICES STANDARD WITH ALL PRIMO MODELS AFCI & 2014 NEC Ready ye, =,F3:ih Prot with LactationM I., yes L)Cdimonnect yes yes [INTERFACESSTANDARD WITH ALL PRIMO MODELS . I• Wi.Fi'/Eth,,net/Sefi.l Wi,el-standard 802.11 b/p. J Fronius S,fIar,veb. Su.Spe,, hititlint, TCP. )SON/ S,inSi-Moilluti RMI f6i0puts m4 digital input outputs ;7_771 relay controls l LISII (A ­ket) L2x-RS452111)45 sadset) J1 F-iiii, Solar Net, interfi- Inbuirul ftaloggei and Webserver Included 'The lerm Wi-fi(b 6 a registered tradmmarL of the Wi Fi Alli,inc,_ Company Information: TECHNICAL DATA FRONIUS PRIMO CY) OUTPUT DATA.- . o . ' L - PRIMO 3.8-1 PRIMO 5.0.1. PRIMO 6.6-1 PRIMO 7. tll _-' - 11 PRIMO 8.2-1 fiax. output power 240 V 3800 W 5000 W 6000 W INPUT DATA J, PRIMO 3.8-1,I PRIMO 5.0.1'. _ -..PRIMOi.D­i`tt1 _1 f PRIMO 7.61 PRIMO 8.2.1 1 M17xr. rnminunus omlrul rurrem 240 V 15.8 A 20.8 A 25.0 A I Reu I.A PV I -in (kA'I,) 3.0-6.0 kW 4.0-7,8 kW 4A-9.3 k%V 6.1 11.7 kW 6.6. 12.7 kW 240 V 20 A 30 A 35A 1 19 A 1187 185 118 A. 3: 8 A 118 A 18 All 8 A 1 1, 16 6 M., Effiri,,..:y 96.? $4 96.9 %, 96.9 % Tolaln­. DC c,.,,..t U) 1 CIC Efficien" 240 7, 1 36 A -1 96.01y Ir9757=1 En Auhni-able-iducto, A-. AC AWG 14 - AWG 6 array short d(cull current It 15 lnua%) thil'I'T 1, 0 - IF * . L t Grid munectirut 22.5 A / 27-5 A I F1.11.1 -Y 60 K,. Oi-ling voltage rting, cu t_Toud li.rimairl. distortion so V - 600 V J "Hill.- Nominal input ­11tige , 4111 420V t 600 V 420 V 42()V 420 V I Recommended PV power (k%A`pJ 8.0 - 12.0 kW 9.1 - 13.7 kW Admissabl, annithuct-ire DC I Miivusable itimorvitout iNiPPT IftIPFT 1-1 AMG_14-AWrb I 'linal-OCcumn, SIA Ni I'll Voltage Range ) 200-480 V 240.480 V 240. 480 V 250 -480 V 270- 480 V Company Information: CY) OUTPUT DATA.- . o . ' L - PRIMO 3.8-1 PRIMO 5.0.1. PRIMO 6.6-1 PRIMO 7. tll _-' - 11 PRIMO 8.2-1 fiax. output power 240 V 3800 W 5000 W 6000 W 7600 W - 8200 W O I F - 0 208 %A mou w - All -5000-W- 11 76M W 7900 �w� 1 M17xr. rnminunus omlrul rurrem 240 V 15.8 A 20.8 A 25.0 A 31.7 A 34.2 A M VE� 757 163 A -Ir-24 7 26�b A 36.5 A 38.0 A= 240 V 20 A 30 A 35A 411 A 45A i. .0521 255 11 305 8 40 A 5-07=1 505 0 M., Effiri,,..:y 96.? $4 96.9 %, 96.9 % 96.9% 97.0% U) 1 CIC Efficien" 240 7, 1 9 5. 5 77 7111 95.5% it `496.0% -1 96.01y Ir9757=1 En Auhni-able-iducto, A-. AC AWG 14 - AWG 6 "0 LP t Grid munectirut 2081240V - I F1.11.1 -Y 60 K,. cu t_Toud li.rimairl. distortion 5.0% J rINPUTDATA010-0-1 P RIM PRIMO 111.4-11 F R11 0 12.5-1 PRIMO 15.01 I Recommended PV power (k%A`pJ 8.0 - 12.0 kW 9.1 - 13.7 kW 10.0 - 15.0 k\V 12.0-18.0 kw I I Miivusable itimorvitout iNiPPT IftIPFT 1-1 A 305 / 18.0 A I 'linal-OCcumn, SIA t MR., aha short rincuilrN_0P=PT2, 1 41.3 A;, 22.5 A I Operitingvolmgerange SOV -600V umax. !"."I -Ilar gE Gf10 V_ Nominal inj I -luigtt 415 V 420 V 1 425 V 440 V 1' mi-ble randuct.,r sire VC 1 1 liv� 6 copper direct, AW6 6 alinnimint 114 d , .0.1AW10 copper or AING 8 aluminium for ove,enmerit pmt�MCM, up 1. 60A, from 61 to I OOA min_ imurn AWL" 8 for copper or MVG 6 aluminium 'hie, In be usat% AWG 4 ..A%VG 2 mpprr or alu-, MIT Voltage Range '2"20-430 V 240x'480 V 260-480 V 320.480 V C string I-,, buldem 4 , slunMPT12 OUTPUT DATA '71 PRIM0110.0-11, PRIMO 11.4-1 11 PiIMO�12.5-1 PRIMO 75.0-1 1 %1-. u.tp.I pul- 240 V 9995 W 11400 W' 12500 W 15000 IN -710-8 V.] 5995 W 114 b Q W 11 12566 w r 13750W. 3 Max. continuous output Linrem 240 V. 41.6 A 47.5 A 521.1 A 62.5 A I-,-, -I - 1=08 y 48.t A' 1 5455 11 60.1A 66. 1 A Recommended OCI-1.)/ACLreikersirs 240 V 60 A 60 A 71) A 80 A f- _ - . W 2TV"I 70A 70A it 80A 905 I i Max. Efficiency 96.7 it, I •EEC �flkielu. 965%. - U 9 6. 5 %, :1 I . . Admissible conduct., size AC ' AWG IU.AWG 2copper (solid / stranded / line stiaiidLd)(AWC 10mppetorAWG $ aluminium for o%,cr�rcniprotective devices I up to 60A, from 61 to I OOA minimum AWG 8 lot copper or AWG ( , aluminium has to be usedl, AWG 6 - AWC 2 c,opperjsolid stranded) hitiltiComacliNiringable with AVVG 12 =Vfld,,eaimi 208 1240 V F,ey,e.u.-y 60 H,. 177 77 _h,-,nkdqqimi 4 2,5% Pit., Ind i PerIM Welding / Sola Enn gy-! Arum Charging - WE HAVE THREE DIVISIONS AND ONE PASSION: SHIFTING THE LIMITS OF POSSIBILITY. Whether welding lechritilgy, lib.1-hiii. - h,a-y charging technology - i,r goal I., clearly d,flin,d: 1. bethe imi-nimi lead,, Wuh-und 3,300 ­plya, ­khAde­,shiF1,h, linni-f.h.1s p-lble-ii-ecouloi-e, 900g,nniled pau,m.6 i-innum, to p-g- Fronius USA LLC ,n,p by t"p. - ;.u. -t,, in leaps and li-A, p", as dun. 11u- 'espo-ibleu-,fuu, rrvnucc uu­,,hrb,,si­!`.­:nr1 ... I,: 1.1ky. 6797 Fronius Drive U_ Portage, IN 46368 USA Re,. 11.3.35 USA pv-suppo.rt-tisa@fronius.com www.froiiius-usa.com Company Information: PROJECT NAME & ADDRESS COSTELLO JOHNSON 790 LIBERTY LANE, CHICO, CA 95928, USA PHONE NO: XXX -XXX ->(XXX APN NO:039-100-023 DATE: 12/18/2017 SHEET NAME EQUIPMENT SPECIFICATION SHEET NUMBER PV -7 CY) O -0 OC) CD CD CV) 0 M i. U-) 01) co 0 _0U < co U) 0 C) En CU (D E "0 LP M cu Cf) I- :3 UJ PROJECT NAME & ADDRESS COSTELLO JOHNSON 790 LIBERTY LANE, CHICO, CA 95928, USA PHONE NO: XXX -XXX ->(XXX APN NO:039-100-023 DATE: 12/18/2017 SHEET NAME EQUIPMENT SPECIFICATION SHEET NUMBER PV -7 • - ` � - .' , w- _ T r Company Information: 1 . A SWH Racking System Data Sheet v.rsion12:1O..v2 ISOLAR WAREHOUSE -SWH Solar Mount Rail ' s •� ' t MFG -PN: MR -SW -SR -10.5, MR -SW -SR -12; MR -SW -SR -14, MR -SW -SR -14B, MR -SW -SR -17 SLOT FOR �.. ` . • n 1/4" T -BOLT _ OR HEX BOLT Rail material: 6063-T5 extruded aluminum alloy SLOT FOR Finish: Clear or black anodized f3/8" T -BOLT s OR HEX BOLT +2.25" y CONFORMS TO UL SUB 2703 SLOT FOR ` y 3/8"T -BOLT x, OR HEX BOLT w US • - - - Intertek - ' .750" 4009330 Properties Units Solar Mount Beam Height in 2.250 Approximate Weight . • .� plf 0.700- .700-Total TotalCross Sectional Area in' 0.588: Area Moment of Inertia X -Axis in 0.299' t Area Moment of Inertia Y -Axis in 0.038' Tensile Strength MPa 190.249' Yield Stregth MPa 165.732' Elongation (G.L.=25mm) %. 17.2 Hardness (HR15T) 71 ' 'updated 6/12/2012 Typical Composition J ' Material % Si % Fe . % Cu % Mn % Mg . % Zn % Ni % Cr % Pb "% Sn % Ti % At - . 6063- 0.3972 0.2679 0.0469 0.0666 0.4936 0.0436 0.0056 0.0205 0.0010 0.0044 0.0188 98.6 _ 1M_ _ -- ., :�. • � .. - �• ._U . • �^ ., ^ I ... (�• -co CIO J rn -, M N C] • cc (D t . co Lf� L J (CN PROJECT NAME & ADDRESS ,..• COSTELLO JOHNSON ' u - - �` 790 LIBERTY LANE, - CHICO, CA 95928, USA PHONE NO: XXX-XXX-XXXX APN NO:039-100_ -023 r� . _. • - r r Company Information: SwrP SWH Rackinq`S stem�Data Sheet version12.lO:v2 SOLAR_ WAREHOUSE>. - �< SWH Solar Mount End Clamp- • End clamp material: 6005-T5 extruded aluminum alloy MFG -PN: MR -SW -EC -35, MR -SW -EC -35B, • _ Finish: Clear or black anodized - MR -SW -EK -40, MR -SW -EK -40B;' - Bolt & nut material: 304 stainless steel and/or 316 stainless ` MR -SW -EF -45, MR -SW -EF -456, • �' steel L MR -SW -EE -50, MR -SW -EE -50B End clamp weight: Varies based on height: 0.052-0.06 lbs ' 'Assemble end clamp with one 1/4"-20 T -bolt and one 1/4-20 ASTM F594 serrated flange nut. - ' t Use anti -seize and tighten to 10 ft -lbs of torque. Module Modules must be installed at least 1.5" -from either.'end.of a 3 - SWH solar mount rail. f ` CONFORMS TO UL SUB_ 2703_ End Clamp O(T us Rail. 7.` - Intertek t 4009330 r o- • y 1S r _Q Hariq i VA RMS Y ; Tmcrtress ! 1-1.x' — Dimensions specified in inches unless noted Part Name •. PartNumber s. Range of HeightsWei (mm) ht (lbs ) (without Hardware "C" end clam 'MR -SW -EC -35 34-36 .054 "C" black end clam - MR -SW -EC -35B 34-36 .054 "Wend clam MR -SW -EK -40 39-41 .056 "K black end clam MR -SW -EK -40B 39-41 .056 "F" end clam MR -SW -EF -45 44-46 .058 ` "F" black end clam MR -SW -EF -45B 44-46 .058 "E" end clamp MR -SW -EE -50 • 49-51 .060 "E" black end clamp I MR -SW -EE -508 1 49-51 1 .060 END CLAMP IS - - END CLAMP IS TOO LONG TOO SHORT 9628 Valley Blvd: Rosemead,` CA 91770 1 Phone 626-579-3288 1 info@esolarwarehouse.com ' Swirl SWH .Racking System Data Sheet -Version 12.10,2 SOLAR WAREHOUSE SWH Solar Mount Mid Clamp - - 4' . MFG -PN: MR -SW -MC -20, MR -SW -MC -20B Mid clamp material: 600545 extruded aluminum alloy ` + Finish: Clear or black anodized • ,Bolt & nut material: 304 stainless steel and/or 316 stainless steel. r Mid clamp weight: 0.058 lbs (without hardware) •. Assemble mid clamp with one'/4"-20 T -bolt and one 1/4"-20 ASTM F594 serrated flange nut _ f^• , Use anti -seize and tighten to 10 ft -lbs of torque + a CONFORMS TO'UL SUB 2703 Mid Clam f = �S Rail Intertek 4009330 ' Module • ` I iT e r Dimensions specified in inches unless otherwise noted A 14 INCORRECT 9628 Valley Blvd. Rosemead, CA 9177011 Phone 626-579-3288 1 info@esolarwarehouse.com,� PROJECT NAME & ADDRESS COSTELLO JOHNSON 790 LIBERTY LANE, CHICO, CA 95928, USA PHONE NO: XXX-XXX-XXXX z APN NO:039-100-023 DATE: • 12/18/2017 SHEET NAME EQUIPMENT SPECIFICATION SHEET NUMBER PV -9 • M ' `C) _ U M qZT ,4 ' O N c LO co (n�V0 - cu CU LP co04 = J PROJECT NAME & ADDRESS COSTELLO JOHNSON 790 LIBERTY LANE, CHICO, CA 95928, USA PHONE NO: XXX-XXX-XXXX z APN NO:039-100-023 DATE: • 12/18/2017 SHEET NAME EQUIPMENT SPECIFICATION SHEET NUMBER PV -9 ,n { - _ -y • i - - y K. - Company'information:. • ♦ • ]• - ,` ' 1.- " Y ` _ ' - ati,s L {`�. '' j t� �_ k .Y _ • • f-•� r' •�� r a i 4 .} t ,1 ^s Rackinq System -Data Sheet ver�;oniuov2 , . , A •f - s y w 'SOLAR WAREHOUSE-- %a ` • 5 ' ;SVM Standoff IGt - 3.5", 5", 8" Standoff Materials:'- ' Y. ' �„ Part No.MR-SW-HP-35S, MR-SW-HP-35SB . • 6061-T6 extruded aluminum alloy MR -SW HPSS, MR-SW-HP-5SB • Mill finish or coated black SWH Standoff Post Only Hardware Materials: r # . , . _ • . - a - _ ry s • 304 stainless steel r•. ; _ - r y ,Part P-3 No.MR-SW-HP-P-35, MR -SW -HP -56 - -. r - - . , - _ _ - • _ � - _ ' -,MR-SW-HP-P-5, MR -SW -HP -P -SB " ` Tighten 3/8" hex nufto L- bracket MR -SW -HP -P-8, MWSW-HP-P-8113 to 20 ft -lbs torque r 3.5" 8r 5" Standoff Kit lndudes:2,2 • 3.5",5"x1 "OD Solid Aluminum Standoff : + - O ' o- • 5116"x 5" Stainless Hanger Bolt ' x ; _.. 3/8"i 1' SS Hex Bok r e - O V:I •3/8" 55 Hat Washer; _ + r U OO �' : " 1.3'x 5116'x 1/8" SS Heavy Flat Washer` . 3 �} _ ` " . _ • M - •• 1.5" x 5/16".x 1/8" Rubber Gasket Lo i 3.5", 5", 8" Standoff Post Only: _ (0 C M • Mounts to SWH Dual Anchor Flange Base for Standoff. } 1 •„ Q U Pan No: MR-SW-HP-BS54M ti ' - /\ >✓ . , CO 35 5 8 •etustratlon not to scale ; - /�� C6 Lf) y, y M M J t .Axial Load Capacity Note: Loads are given for standoff only. Check load limits for lag screw �_ _ or other attachment methods y _ - 'r• DATE: " 12/18/2017 3 x r V t,ls SHEET NAME •IndependentLaboratory Tested EQUIPMENT 'SPECIFICATION 9628 Valley BFA._Rosemead; CA 91770 I Phone 626-579.'32i38 ''1 infooesoldrwarehouse com t r t ' SHEET NUMBER, Average Average Standoff Assembled Part Ultimate Load Ultimate Load , Dimension Weight (lbs) Yt (lbs) Zt OD x H - MR -SW -HP -35S 893 ` 8601 1":x 3.5" 0.444 lbs MR -SW -HP -5S 928` 9007 -- _1 x5" 0.562 lbs ` DATE: " 12/18/2017 3 x r V t,ls SHEET NAME •IndependentLaboratory Tested EQUIPMENT 'SPECIFICATION 9628 Valley BFA._Rosemead; CA 91770 I Phone 626-579.'32i38 ''1 infooesoldrwarehouse com t r t ' SHEET NUMBER,