Loading...
HomeMy WebLinkAboutB18-0046 027-070-071BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES INSPECTION CARD MUST BE ON JOB SITE i. 24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for, inspections is 3pm) Development Services cannot euarantee inspections on the'date requested Office: 530.538.7601 Fax: 530.538.7785 www.BuneCounty.net/dds Permit No: B18-0046 Issued: 1/5/2018 APN: 027-070-071 Address: 84 CYNTHIANN LN, PALERMO Owner: WELLS BEN DEE & KOLLEEN Permit Type: SOLAR ROOF -RES Description: INSTALL8.54KW SOLAR TO SERVE RES & F FV611-0 7 Flood Zone: : SRA Area: SETBACKS for Zoning, AG. RA. PW Front: Centerline of Road: Rear: SRA: Street: AG: Interior Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING Inspection Type IVR INSP DATE Setbacks 131 Foundations /Footings III Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Signed Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts . 319 Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 Blockin nde inin 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed Shearwall/B.W.P.-Interior 134 Shearwall/B.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 417 Manometer Test Do Not Install Siding/Stucco or R)ofrng Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed Inspection Type IVR INSP DATE T -Bar Ceiling' 145 Stucco Lath 142 Plumbing Final 813 Fire Sprinkler Test or Final 702 Swimming Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 503 Pre -Plaster 507 Manufactured Homes . Setbacks 131 Blockin nde inin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Underground Electric 218 Sewer V, 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Skirting/Steps/Landings 610 Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: Length x Width: Insignia: 4 _ W y n'P nals , Permit Final 802 kcA ,.I LZ A Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test or Final 702 Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final "PROJECT. FINAL *Project Final is a Certificate of Occupancy for (Residential Only) PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION I PV SYSTEM SUMMARY: 8.235 KW ROOF MOUNT RESIDENTIAL PHOTOVOLTAIC SYSTEM SYSTEM SIZE (DC) STC: 27 X 305= 8235W DC . PTC: 27 X 279.20 = 7538.40W DC SYSTEM SIZE (CEC-AC) 27 X 279.20 X 98% = 7387.63W AC MODULES 27 X HANWHA Q -CELL. Q PEAK -G4.1' 305, 305W MODULES INVERTER SOLAR EDGE SE760OH-US ROOF COMPOSITION SHINGLE } t TILT 23° PITCH AZIMUTH : 175° & 355° RAFTER/TRUSS SIZE : 2" X 4" TRUSSES @ 24" O.0 ATTACHMENT TYPE FLUSH FOOT MOUNT WITH IRONRIDGE XR100 RAIL MAIN SERVICE PANEL EXISTING 200 AMPS MAIN PANEL WITH 200 AMPS MAIN BREAKER ON TOP FEED INTERCONNECTION PV BREAKER TIED INTO 125 AMP SUBPANEL WITH 100 MAIN BREAKER AT BOTTOM FEED OCPD RATING 40 AMPS STRINGING 1 STRING WITH 14 MODULES AND 1 STRING WITH 13 MODULES IN SERIES IN EACH STRING UTILITY : PACIFIC GAS AND ELECTRIC COMPANY (PGE) TABLE OF CONTENTS PV -1 SITE LOCATION AND HOUSE AERIAL VIEW PV -2 SITE PLAN PV -2A ROOF PLAN WITH MODULES LAYOUT PV -3 ELECTRICAL LINE DIAGRAM PV -4' ROOF MOUNTING DETAILS, ELEC'. CALCULATION & MATERIAL LIST - PV -5 LABELS PHOTOVOLTAIC SYSTEM CITY NOTES: THIS PROJECT COMPLIES WITH THE FOLLOWING: 2016 CALIFORNIA BUILDING CODE (CBC) 2016 CALIFORNIA ELECTRICAL CODE (CEC) 2016 CALIFORNIA FIRE CODE (CFC) 2016 CALIFORNIA PLUMBING CODE 2016 CALIFORNIA MECHANICAL CODE 2016 CALIFORNIA ENERGY CODE 2016 CALIFORNIA RESIDENTIAL CGDE 2016 CALIFORNIA ADMINISTRATIVE CODE AS ADOPTED BY COUNTY OF BUTTE ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY ARE MOUNTED VISIBLE PORTIONS OF THE SOLAR PANEL SUPPORT STRUCTURE AND ANY EXPOSED ELECTRICAL CONDUITS, BOXES AND PANELS WILL NOT BE' EXPOSED, AND WILL BE COLORED MATCHED TO EXISTING ROOF OR SURROUNDING HOME. MODULES SHALL BE TESTED, LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN ACCORDANCE WITH UL 1703. THE FIRE CLASSIFICATION SHALL COMPLY WITH TABLE 1505.1 OF THE CALIFORNIA BUILDING CODE BASED ON THE TYPE OF CONSTRUCTION OF THE BUILDING. CRC SECTION R902.4 SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER CRC SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. RESIDENTIAL BUILDING UNDERGROUND ADDITION OR IMPROVEMENTS SHALL REPLACE NON-COMPLIANT PLUMBING FIXTURES WITH WATER CONSERVING PLUMBING FIXTURES IN ACCORDANCE WITH CGBSC . SECTION301.1.1 AND CIVIL CODE 1101.1 AS FOLLOWS: —WATER CLOSETS: 1.6 GPF (GPF= GALLONS PER FLUSH) —FAUCETS (ALL INTERIOR) 2.2 ( GPM = GALLIONS PER MINUTE) URINALS 1.0 GPF —SHOWER HEADS 2.5 GPM INSTALLATION NOTES: THE PV BREAKER SHALL NOT EXCEED 120% OF THE ALLOWABLE BACK FEED OF THE MAIN SERVICE BUSS RATING. PV WIRE SHALL BE USED ON DC RUNS FOR UNGROUNDED/TRANSFORMERLESS INVERTERS. INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUITS ARE ATTACHED TO THE ROOF USING PRESSURE TREATED WOOD IN CASE OF COMPOSITE ROOF OR COUNDUIT HANGERS IN CASE OF CONCRETE ROOF r SITE LOCATION: Lone Wolf Enteipiise§ ^_ _ :.ate: 84 Cynthianntane SITE LOCATION HOUSE AERIAL VIEW: Ew6,,1C,n1,=rNo: CLIENT: REVISIONS: DATE: 12/20/2017 TITLE: SHEET: C-10 982892 7 Freedom Solar WELLS, KOLLEEN + DESCRIPTION DATE REVISION 84 CYNTHIANN LANE, DESIGN GREG SITE LOCATION AND PV_� Freedom Solar Co OROVILLE, CA 95966 HOUSE AERIAL VIEW 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 (530) 370-6341 Tel: (800) 385-1075 - JOB NO.: FS -12-075 MAIN HOUSE: 1307.34 SQ FT ROOF AREA: 1034.74 SQ FT SHED AREA: 533.92 SQ FT 786-4„ _ PROPERTY LINE ._ 764„ \ MAIN HOUSE 10T-10” 373' \—' MAIN SERVICE PANEL SHED SUB PANEL 371' / 2w 389'-4" DRIVEWAY • 2 Q N 451'-7"' 3_ to cv a> (N) 27 HANWHA Q -CELL. Q PEAK -G4.1 / ca 305, 305W MODULES / ROOF LINE 184'-11" — — — — — — — — — — 762'-7" — — — — — — SITE• PLAN SCALE: 1/64" = V-0" • ti • 4 eiearica ccmadur"o: CLIENT: REVISIONS: TITLE: SHEET: C-10 982892 DESCRIPTION DATE REVISION DATE: 12/20/2017 Freedom Solar WELLS, KOLLEEN 84 CYNTHIANN LANE, DESIGN Freedom Solar Co OROVILLE, CA 95966 BY: GREG SITE PLAN PV -2 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 (530) 370-6341 Tel: (800) 385-1075 JOB NO.: FS -12-075 NOTE: EMT CONDUIT SUPPORTED BY PIPE Q HANGERS 12" TO 18" AWAY FROM ROOF EDGE ATTACH CLAMP AT 25% FROM EDGE AND 50% FROM CENTER OF MODULES Q JUNCTION BOX MOUNTED TO THE RAIL LEGEND: ® CHIMNEY O PIPE VENT (N) SOLAR EDGE SE760OH-US INVERTER (N) AC DISCONNECT – SU& PANEL — ISUB AC INV 71, i o "A. I c � �A� I I I FIRE SETBACKS 3' TYP � yl I,I�i' 1/�lfll r ©N) 3/4" OR LARGER EMT II! ��` i5/ CONDUIT t��f4✓� I I I (N) 27 HANWHA Q -CELL. Q PEAK -G4.1': "o 305, 305W MODULES 2�(N) ATTACHMENT POINTS @ `,� A'�', I I I 72" O.C. MAX. FIRE ACCESS POINTS E,Iectdcal Co"hedor No: CLIENT: -• . Freedom Solar C-10 982892 .. Freedom Solar Co 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 Tel: (800) 385-1075 WELLS, KOLLEEN 84 CYNTHIANN LANE, OROVILLE, CA 95966 (530) 370-6341 ROOF AREA STATEMENT DU ES PITCH AZIMTUH ROOF MODULES ROOF AREA ARRAY AREA 1 16 23° 175° 517.37 SQ FT 294.00 SQ FT 2 11 230 355° 517.37 SQ FT 1 201.84 SQ FT REVISIONS: DESCRIPTION a 2" X 4" TRUSSES @ 24" O.0 (TYP.) ROOF PLAN WITH MODULES LAYOUT 1 SCALE: 1/8" = V-0" TITLE: SHEET: DATE REVISION DATE: 12/20/2017 DESIGN BY: GREG JOB NO.: FS -12-075 ROOF PLAN WITH MODULES LAYOUT PV -2A I Max. OCPD: (125A Bus) " (1.2) = 150A Max Rating (120% of Bus) PV Backfeed (40A) + Maim Breaker (100A) = (140A:5 150A) See 705.12 (D)(2)(3)(b) of 2016 CEC STRING -1 14 HANWHA Q -CELL. Q PEAK .G4.1 305, 305W MODULES I I I STRING -2 I 13 HANWHA Q -CELL. Q PEAK -G4 305, 305W MODULES I I I I I I I 2 - #10 AWG, PV WIRE 1 - #6 EGC, BARE COPPER (TYP.2) n 0 SOLAREDGE P320 POWER OPTIMIZERS JUNCTION BOX I I I I 4 - #10 AWG, THWN-2 1 - #8 EGC, THWN-2 1 - #8 GEC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT INVERTER SOLAR EDGE SE760OH-US RAPID SHUTDOWN AC SWITCH DC - SOLAREDGE P320 3 - #8 AWG, THWN-2 POWER OPTIMIZERS 1 - #8 EGC, THWN-2 1 - #8 GEC, THWN- 2 IN 3/4" OR LARGER EMT CONDUIT (E) 125A (E) 200A MAIN SUB PANEL BREAKER 100A / 2P o� O (N) 40A / 2P PV BREAKER 40A / 2P •�~ o 0 0.1 .�. 60A, AC I I DISCONNECT I I 106A 2P I I , I I -- ° -- -----------------.J L_ (E) 200A MAIN SERVICE PANEL UTILITY METER -I . UM (E) 100A / 2P SUB PANEL BREAKER I • I I; • I EXISTING FEEDERS JL------------------ too EXISTING CONDUIT I L------------------------ THE GROUNDING ELECTRODE CONDUCTOR SHALL BE CONNECTED PV BREAKER SHALL BE INSTALLED AT FROM THE ARRAY FRAME DIRECTLY TO THE OPPOSITE END OF THE BUS BAR. A GROUNDING ELECTRODE CONNECT TO EXISTING UFER General Notes: 1. (27) HANWHA Q -CELL. Q PEAK -G4.1 305, 305W MODULES wired and listed to UL1703 standards T 2. SOLAR EDGE SE760OH-US Inverter with integrated DC Disconnect and Arc Fault Protection. Attached with system electrical specifications and ground fault protected & listed to UL1741 standards. 3. Photovoltaic system ground will be tied into existing ground at main service from DC Disconnect/Inverter as per CEC Sec. 250.166(A). "The Grounding Electrode Conductor shall not be smaller than the neutral conductor and not smaller than 8AWG copper." 4. Equipment operating 150 volts or greater shall only be serviced or replaced by qualified personnel. Field protection may be in the form of conduit, closed cabinet or an enclosure which requires use of tools to open. 5. Solar Photovoltaic System equipment will be installed in accordance with requirements of Art. 690 of the 2016 CEC. 6.Minimum height of conduit above roof to match temperature derating factor. 7.Photovoltaic DC conductors entering the building shall be installed in metallic raceway and shall be identified every 10 feet -- and within 1 foot above and below penetrations of roof/ceiling assemblies, walls, or barriers -- with minimum 3/8 -inch -high white lettering on red background reading: "WARN ING: PHOTOVOLTAIC POWER SOURCE" z 8. System Grounding Electrode conductor for PVsystem.to be sized to meet.the requirements of-CEC 2016 table 25.0.66_ , not smaller than #8 CU AWG." - 9. If the existing main service panel does not have a ground rod or, ufer, it is the pv contractors responsibility install one. 10. Smoke alarms and carbon monoxide detectors will meet the necessary requirements per CRC R314, R315 11. UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM. 12.Terminals of the disconnecting means may be energized in the open position. 13. A signage labeled "SOLAR LOADS ONLY" is to be installed on dedicated solar sub panel to be used for PV only.' 14. Solaredge inverters are listed to UL1741 and UL1699B standards. 15. Solaredge Optimizers are listed to IEC62109-1 (class II safety) and UL1741 standards. 16. PV system is using continuous grounding method with #6 bare copper wire. E11114111 C-1 11o, NOl CLIENT: REVISIONS: DATE: 12/20/2017],TITLE: SHEET: E • :: •' Freedom Solar c-10 982892 WELLS, KOLLEEN DESCRIPTION DATE REVISION O 84 CYNTHIANN LANE, DESIGN ELECTRICAL Freedom Solar CO oROVILLE, CA 95966 BY; GREG LINE DIAGRAM, PV -3 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 (530) 370-6341 Tel: (800) 385-1075 ' 106 NO.: FS -12-075 ELECTRICAL CALCULATIONS _ MATERIAL LIST PV MODULE, . EQUIPMENT. r DESCRIPTION- • ' t BY OTHERS ~ PV MODULE, HANWHA Q-CELL. MAX. POWER VOLTAGE (Vmp) : IRONRIDGE BY OTHERS 'Q PEAK -G4.1'305, BACKFEED BREAKER SIZING 9.84A RAIL _ _ _ _ _ _ _ _ IRROI NRIDGE MAX. POWER CURRENT (Imp) : MAX. CONTINUOS OUTPUT 32A @ 240VRA _ 279.2W SOLAR EDGE s- ' (E) ROOF as (E) ROOF, 32• X ; 1.25,-- = 40.00AMPS 46A BREAKER,= OK : MAX- AC OUTPUT VOLTAGE RANGE: MEMBRANE MEMBRANE WITH POWER MAX. AC OUTPUT CURRENT: 32A n MAX. AC POWER OUPUT.: CEC 705:12 (D) (2) (3) (b)' - ' IRONRIDGE - r _ FLASHFO_OT2 IRONRIDGE _ 'FLASHFOOT2 98%' F • 125 X- 1.20 = 150 - ' JUNCTION BOX 60OVDC, NEMA 4X, UL LISTED .. ' 1' AC DISCONNECT' _150 - 100 =. ; 50,A ALLOWABLE BACKFEED 1 (E) BUILDING (E) BUILDING '.42 Y FLUSH FOOT MOUNT STRUCTURE tc STRUCTURE. IRONRIDGE XR100 r DE RMPACITY OF8 AWG CONDUCTOR 0.87 % �. 46 MID CLAMPS ; -RATED @ TEMPERATURE CORRECTION , 16 END CLAMPS jIRONRIDGE XR100 END CLAMPS 40' 55. X 0.87 v_ = 47.85_ AMPS - OK, 'yR ;3/4" OR LARGER EMT CONDUIT ' • - r Y .` ,• fir.» �,• y `; .e . l r • Existing composition `• a _. shingle roof End Clamp - 1 ` Photovoltaic ' Module ,• , - ti 5/16" diameter 3.5" length lag screw QTY EQUIPMENT. r DESCRIPTION- • ' -OPEN CIRCUIT VOLTAGE (Voc)': 40.05V� HANWHA Q-CELL. MAX. POWER VOLTAGE (Vmp) : 32.62V ;. 27 'Q PEAK -G4.1'305, SHORT CIRCUIT CURRENT (Isc) : 9.84A • 305W MODULES MAX. POWER CURRENT (Imp) : 9.35A PTC RATING : 279.2W SOLAR EDGE MAX. DC INPUT VOLTAGE: 350V SE7600H-US MAX- AC OUTPUT VOLTAGE RANGE: 211-246V 1 WITH POWER MAX. AC OUTPUT CURRENT: 32A MAX. AC POWER OUPUT.: 7600W OPTIMIZER •'., CEC EFFICIENCY : 98%' 1 JUNCTION BOX 60OVDC, NEMA 4X, UL LISTED .. ' 1' AC DISCONNECT' 600VAC, 60A,1NEMA 3R, UL -LISTED 1 PV BREAKER, 2 POLE, 240V, 40A '.42 ATTACHMENTS FLUSH FOOT MOUNT 150' RAIL' IRONRIDGE XR100 IRONRIDGE XR100 GROUNDING 46 MID CLAMPS ; MID CLAMPS 16 END CLAMPS jIRONRIDGE XR100 END CLAMPS 40' CONDUIT, ''� � 'yR ;3/4" OR LARGER EMT CONDUIT ' E1ectncal Cont—tor No CLIENT: REVISIONS: - -TITLE: ' SHEET: _ DATE: 12/20/2017' C-10 982892 ' - ROOF MOUNTING Freed WELLS, KOLLEEN DESCRIPTION .DATE REVISION . 84 CYNTHIANN LANE,," DESIGN GREG DETAILS, ELEC. PV -4 Fr@2dom' SOIar CO OROVILLE, CA 95966„ CALCULATION '& 25819 Jefferson Ave, Suite 110, Murrieta, -CA 92562 (530)370-6341. ' 'Joe NO:: FS=12075 MATERIAL LIST '.. • Tel: (800) 385=1.075 -,' --LABELS: LABELS SPECIFICATION: 1. ALL CAPITAL LETTERS 2. MINIMUM 3/8" LETTER HEIGHT 3. ARIAL OR SIMILAR, NON -BOLD 4. WHITE LETTERING IN RED BACKGROUND 5. WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (DURABLE ADHESIVE MATERIALS MUST MEET THIS REQUIREMENT 6. ALL SIGNS SHOULD BE "REFLECTIVE CAUTION: POWER TO THIS•BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING MAIN PANELSOURCES WITH DISCONNECTS' Q LOCATED AS SHOWN Q WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL 27 PV MODULE ) WITH 6le d.1C.M.M,N. - CLIENT: Freedom Solar C-10 982892 Freedom Solar Co 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 Tel: (800) 38571075 DISCONNECTION MEANS ALL AC AND DC DISCONNECTS TO BE MARKED AS DISCONNECTING MEANS PER CEC 2016 690.13(B) AC DISCONNECT PHOTOVOLTAIC DISCONNECT FOR UTILITY OPERATION INVERTER OUTPUT CONNECTION TO BE INSTALLED AT MAIN SERVICE PANEL PER CEC 2016 705.12 (D) MARKING SHOULD BE PLACED ON ALL INTERIOR AND EXTERIOR PV CONDUIT, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES, EVERY 10 FEET, AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS AND ALL PV COMBINER AND JUNCTION BOXES. WARNING'', PHOTOVOLTIC POWER SOURCE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION; TO BE INSTALLED AT DISCONNECTING MEANS PER CEC 2016 690.17 WARNING ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. PHOTOVOLTAIC POWER SOURCE SHALL BE LABELED WITH THE FOLLOWING WARNING AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT, AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE PER CEC690.35(F) WARNING ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. WELLS, KOLLEEN 84 CYNTHIANN LANE, OROVILLE, CA 95966 (530)370-6341 WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED WARNING. INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE 690.12 COMPLIANT PHOTOVOLTAIC SYSTEM, EQUIPPED WITH RAPID SHUTDOWN DIRECT-CURRENT PHOTOVOLTAIC POWER SOURCE TO BE INSTALLED AT INVERTER PER CEC 690.53 OPERATING CURRENT: 17.9A OPERATING VOLTAGE: 350.00V SHORT-CIRCUIT CURRENT: 23.62A MAX SYSTEM VOLTAGE: 500.00V AC DISCONNECT PHOTOVOLTIC DISCONNECT FOR UTILITY OPERATION WARNING. ELECTRIC SHOCK HAZARD CONTACT QUALIFIED SERVICE PERSONNEL FOR ASSISTANCE Nominal Voltage 240 Volts Nominal AC Frequency 60 Hz Maximum AC Power 7600 Watts Maximum AC Current 40.00 Amps Max.Overcurrent Device 40 Amps Max. Current per Pole 40.00 Amps REVISIONS: DESCRIPTION . •I DATE I REVISION DATE: 12/20/2017 DESIGN BY: GREG JOB NO.:I FS -12-075 0 TITLE: LABELS SHEET: PV -5 PV SYSTEM SUMMARY: 8.235 KW ROOF MOUNT RESIDENTIAL PHOTOVOLTAIC SYSTEM SYSTEM SIZE (DC) STC: 27 X 305= 8235W DC PTC: 27 X 279.20 = 7538.40W DC SYSTEM SIZE (CEC-AC) 27 X 279.20 X 98% = 7387.63W AC MODULES 27 X HANWHA Q -CELL. Q PEAK -G4.1 305, 305W MODULES INVERTER SOLAR EDGE SE760OH-US ROOF COMPOSITION SHINGLE TILT 23° PITCH AZIMUTH : 175° & 355° RAFTER/TRUSS SIZE : 2" X 4" TRUSSES @ 24" O.0 ATTACHMENT TYPE FLUSH FOOT MOUNT WITH IRONRIDGE XR100 RAIL MAIN SERVICE PANEL EXISTING 200 AMPS MAIN PANEL WITH 200 AMPS MAIN BREAKER ON TOP FEED INTERCONNECTION PV BREAKER TIED INTO 125 AMP SUBPANEL WITH 100 MAIN BREAKER AT BOTTOM FEED - OCPD RATING : 40 AMPS STRINGING 1 STRING WITH 14 MODULES AND 1 STRING WITH 13 MODULES IN SERIES IN EACH STRING UTILITY : PACIFIC GAS AND ELECTRIC COMPANY (PGE) TABLE OF CONTENTS PV -1 SITE LOCATION AND HOUSE AERIAL VIEW PV -2 SITE PLAN PV -2A ROOF PLAN WITH MODULES LAYOUT PV -3 ELECTRICAL LINE DIAGRAM PV -4 ROOF MOUNTING DETAILS, ELEC. CALCULATION & MATERIAL LIST PV -5 LABELS PHOTOVOLTAIC SYSTEM CITY NOTES: THIS PROJECT COMPLIES WITH THE FOLLOWING: 2016 CALIFORNIA BUILDING CODE (CBC) 2016 CALIFORNIA ELECTRICAL CODE (CEC) 2016 CALIFORNIA FIRE CODE (CFC) 2016 CALIFORNIA PLUMBING CODE 2016 CALIFORNIA MECHANICAL CODE 2016 CALIFORNIA ENERGY CODE 2016 CALIFORNIA RESIDENTIAL CODE 2016 CALIFORNIA ADMINISTRATIVE CODE AS ADOPTED BY COUNTY OF BUTTE ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY ARE MOUNTED VISIBLE PORTIONS OF THE SOLAR PANEL SUPPORT STRUCTURE AND ANY EXPOSED ELECTRICAL CONDUITS, BOXES AND PANELS WILL NOT BE EXPOSED, AND WILL BE COLORED MATCHED TO EXISTING ROOF OR SURROUNDING HOME. MODULES SHALL BE TESTED, LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN ACCORDANCE WITH UL 1703. THE FIRE CLASSIFICATION SHALL COMPLY WITH TABLE 1505.1 OF THE CALIFORNIA BUILDING CODE BASED ON THE TYPE OF CONSTRUCTION OF THE BUILDING. CRC SECTION R902.4 SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER CRC SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. RESIDENTIAL BUILDING UNDERGROUND ADDITION OR IMPROVEMENTS SHALL REPLACE NON-COMPLIANT PLUMBING FIXTURES WITH WATER CONSERVING PLUMBING FIXTURES IN ACCORDANCE WITH CGBSC SECTION301.1.1 AND CIVIL CODE 1101.1 AS FOLLOWS: WATER CLOSETS: 1.6 GPF (GPF= GALLONS PER FLUSH) —FAUCETS (ALL INTERIOR) 2.2 ( GPM = GALLIONS PER MINUTE) —URINALS 1.0 GPF SHOWER HEADS 2.5 GPM INSTALLATION NOTES: THE PV BREAKER SHALL NOT EXCEED 120% OF THE ALLOWABLE BACK FEED OF THE MAIN SERVICE BUSS RATING. PV WIRE SHALL BE USED ON DC RUNS FOR UNGROUNDED/TRANSFORMERLESS INVERTERS. INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUITS ARE ATTACHED TO THE ROOF USING PRESSURE TREATED WOOD IN CASE OF COMPOSITE ROOF OR COUNDUIT HANGERS IN CASE OF CONCRETE ROOF SITE LOCATION: - _ ...'. mar- ' -�?y: _ _•--•- ,-., _�,t._.......-.-. r.-... _,.-.. ._ - .. ',.LoriWolt:Enterprises - w-- _ — 84 Cynthiann-Lane SITE LOCATION HOUSE AERIAL VIEW: ElBtlriwl C,n1,111r NO: CLIENT: REVISIONS:TITLE: SHEET: C-10 982892 DATE: 12/20/2017 Freedom Solar WELLS, KOLLEEN DESCRIPTION DATE REVISION 84 CYNTHIANN LANE, DESIGN GREG SITE LOCATION AND PV_� Freedom Solar Co OROVILLE, CA 95966 BY: HOUSE AERIAL VIEW 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 (530) 370-6341 Tel: (800) 385-1075 JOB NO.: FS -12-075 MAIN HOUSE: 1307.34 SQ FT ROOF AREA: 1034.74 SQ FT SHED AREA : 533.92 SQ FT 786-4,' PROPERTY LINE 75'-2" — MAIN HOUSE 11 10TH 373' MAIN SERVICE PANEL SHED SUB PANEL 371' 389'-4" DRIVEWAY 2= N 451'-7" /c. V (N) 27 HANWHA Q -CELL. Q PEAK -G4.1 / co 305, 305W MODULES / ROOF LINE 184'-11" SITE PLAN SCALE: 1/64"= 1'-0" Ela&.' alcoohaot rNo' CLIENT: - REVISIONS: DATE: 12/20/2017 TITLE:. SHEET: OFreedom Solar c-10 9s2892 WELLS, KOLLEEN DESCRIPTION DATE REVISION - a 84 CYNTHIANN LANE, DESIGN Freedom Solar Co OROVILLE, CA 95966 BY: GREG SITE PLAN PV -2 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 (530) 370-634.1 106 NO.: FS -12-075 . _ Tel: (800) 385-1075 • NOTE: EMT CONDUIT SUPPORTED BY PIPE Q HANGERS 12" TO 18" AWAY FROM ROOF EDGE ATTACH CLAMP AT 25% FROM EDGE AND 50% FROM CENTER OF MODULES Q JUNCTION BOX MOUNTED TO THE RAIL LEGEND: ® CHIMNEY O PIPE VENT (N) SOLAR EDGE SE7600H-US 1""/CoTC0 (N) AC DISCO SUB P/ FIRE SETBACKS T TYP ©N) 3/4" OR LARGER EMT CONDUIT (N) 27 HANWHA Q -CELL. Q PEAK -G4.' 305, 305W MODULES A22(N) ATTACHMENT POINTS C 72" O.C. MAX FIRE Ar'GL-%--� r.Jl 111 X 4" TRUSSES @ 24" O.0 (TYP.) ROOF PLAN WITH MODULES LAYOUT 1 SCALE: 1/8" = V-0" e!2a miCo"t-aorNo� CLIENT: REVISIONS: TITLE: SHEET: C-10 982892 DATE: 12/20/2017 :: Freedom Solar WELLS, KOLLEEN DESCRIPTION DATE REVISION 84 CYNTHIANN LANE, DESIGN GREG ROOF PLAN WITH PV -2A Freedom Solar CO OROVILLE, CA 95966. BY: (530) 370-6341 MODULES LAYOUT 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 loe NO.: FS -12-075 Tel: (800) 385-1075 ROOF AREA STATEMENT ROOF MODT1LES PITCH AZIMTUH ROOF AREA ARRAY AREA 1 16 23. 175° 517.37 SQ FT 294.00 SQ FT 2 11 230 355° 517.37 SQ FT 201.84 SQ FT X 4" TRUSSES @ 24" O.0 (TYP.) ROOF PLAN WITH MODULES LAYOUT 1 SCALE: 1/8" = V-0" e!2a miCo"t-aorNo� CLIENT: REVISIONS: TITLE: SHEET: C-10 982892 DATE: 12/20/2017 :: Freedom Solar WELLS, KOLLEEN DESCRIPTION DATE REVISION 84 CYNTHIANN LANE, DESIGN GREG ROOF PLAN WITH PV -2A Freedom Solar CO OROVILLE, CA 95966. BY: (530) 370-6341 MODULES LAYOUT 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 loe NO.: FS -12-075 Tel: (800) 385-1075 Max. OCPD: (125A Bus) * (1.2) = 150A Max Rating (120% of Bus) PV Backfeed (40A) + Main Breaker (100A) = (140A <_ 150A) See 705.12 (D)(2)(3)(b) of 2016 CEC STRING -1 14 HANWHA Q -CELL, Q PEAK -G4.1 305, 305W MODULES I STRING -2 13 HANWHA Q -CELL. Q PEAK -G4.1 j. 305, 305W MODULES I I I I I ' I 0 SOLAREDGE P320 POWER OPTIMIZERS 4 - #10 AWG, THWN-2 1 - #8 EGC, THWN-2 1 - #8 GEC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT (N) 40A / 2P PV BREAKER INVERTER SOLAR EDGE SE7�60OHUS \ I ACI i 1010 JUNCTION �b BOX ------ ---- ---= \ b b I � I -4 I I '7 I L--------------------- ---- 2 - #10 AWG, PV WIRE 1 - #6 EGC, BARE COPPER (TYP.2) RAPID SHUTDOWN SWITCH 60A, AC. (E) 125A (E) 200A MAIN SUB PANEL BREAKER 100A / 2P o� 0 /2P o I I I DISCONNECT I i 100A / 72P I I I I ------ — o ----------------=--Fi = L— I • I SOLAREDGE P320 I L---------------- POWER OPTIMIZERS 3 - #8 AWG, THWN-2 EXISTING FEEDERS 1 #8 EGC, THWN-2 EXISTING CONDUIT 1 -#8 GEC, THWN-2 L_______________________ IN 3/4" OR LARGER EMT CONDUIT THE GROUNDING ELECTRODE CONDUCTOR SHALL BE CONNECTED PV BREAKER SHALL BE INSTALLED AT FROM THE ARRAY FRAME DIRECTLY TO (E) 206A MAIN SERVICE PANEL UTILITY METER (E) 100A / 2P SUB PANEL BREAKER THE OPPOSITE END OF THE BUS BAR. A GROUNDING ELECTRODE - CONNECT TO EXISTING UFER General Notes: 1. (27) HANWHA Q -CELL. Q PEAK -G4.1 305, 305W MODULES wired and,listed to UI -17.03 standards _ 8. System Grounding Electrode conductor for PV system to be sized to meet the requirements of. CEC 2016 table 250.66, not smaller than #8 CU AWG." 2. SOLAR EDGE SE760OH-US Inverter with integrated DC Disconnect and Arc Fault Protection. Attached with system electrical specifications and ground fault protected & listed to UL1741 standards. 9. If the existing main service panel does not have a ground rod or ufer, it is the pv contractors responsibility install one. 3. Photovoltaic system ground will be tied into existing ground at main service from DC Disconnect/Inverter as per CEC Sec. 250.166(A). "The Grounding Electrode Conductor shall not be smaller than the neutral conductor and not smaller than 8AWG copper." 4. Equipment operating 150 volts or greater shall only be serviced or replaced by qualified personnel. Field protection may be in the form of conduit, closed cabinet or an enclosure which requires use of tools to open. 5. Solar Photovoltaic System equipment will be installed in accordance with requirements of Art. 690 of the 2016 CEC 6.Minimum height of conduit above roof to match temperature derating factor. 7.Photovoltaic DC conductors entering the building shall be installed in metallic raceway and shall be identified every 10 feet -- and within 1 foot above and below penetrations of roof/ceiling assemblies, walls, or barriers -- with minimum 3/8 -inch -high white lettering on red background reading: "WARN ING: PHOTOVOLTAIC POWER SOURCE" �IectdcalContmdorNo: CLIENT: OFreedom Solar . C-10 982892 WELLS, KOLLEEN 84 CYNTHIANN LANE, Freedom Solar Co OROVILLE, CA 95966 25819 Jefferson Ave; Suite 110, Murrieta, CA 92562 (530) 370-6341 Tel: (800) 385-1075 10. Smoke alarms and carbon monoxide detectors will meet the necessary requirements per CRC R314, R315 11. UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM. 12.Terminals of the disconnecting means may be energized in the open position. 13. A signage labeled "SOLAR LOADS ONLY" is to be installed on dedicated solar sub panel to be used for PV only. 14. Solaredge inverters -are listed to UL1741 and UL1699B standards. 15. Solaredge Optimizers are listed to IEC62109-1 (class II safety) and UL1741 standards. 16. PV system is using continuous grounding method with #6 bare copper wire. REVISIONS: DESCRIPTION DATE I REVISION DATE: 12/20/2017 DESIGN BY: GREG JOB NO.: FS -12-075 TITLE: ELECTRICAL LINE DIAGRAM SHEET: PV -3 PV MODULE,. BY OTHERS PV MODULE, IRONRIDGE' BY OTHERS BACKFEED BREAKER SIZING y IRONRIDGE RAIL — — — — — — — — RAIL MAX. CONTINUOS OUTPUT 32A @ 240VNIS Y ` (E) ROOF (E) ROOF 32` X 1.25 = 40.00AMPS 40A BREAKER- OK :. MEMBRANE MEMBRANE CEC 705.12 (P) (2).(3) IRONRIDGE ' IRONRIDGE 125 X 1.20• . =r 150 ' FLASHFOOT2 FLASHFOOT2 150. - 100 50AALLOWABLE BACKFEED" . (E) BUILDING (E) BUILDING STRUCTURE STRUCTURE DERATED AMPACITY OF 8 AWG CONDUCT_ OR @ 0.87 TEMPERATURE CORRECTION 55 X . 0.87 47.85 AMPS - OK - Existing composition shingle roof , T End Clamp. Photovoltaic _ i Module. 5/16" diameter 3:5" length lag screw QTY EQUIPMENT DESCRIPTION OPEN CIRCUIT VOLTAGE (Voc) : 40,05V HANWHA Q -CELL. MAX. POWER VOLTAGE (Vmp) : 32.62V, 27 --ELECTRICAL CALCULATIONS. . ' SHORT CIRCUIT CURRENT (Isc) : MATERIAL LIST 305W MODULES. MAX. POWER_ CURRENT.(Imp) : 9.35A PTC RATING: 279.2W , SOLAR EDGE PV MODULE,. BY OTHERS PV MODULE, IRONRIDGE' BY OTHERS BACKFEED BREAKER SIZING y IRONRIDGE RAIL — — — — — — — — RAIL MAX. CONTINUOS OUTPUT 32A @ 240VNIS Y ` (E) ROOF (E) ROOF 32` X 1.25 = 40.00AMPS 40A BREAKER- OK :. MEMBRANE MEMBRANE CEC 705.12 (P) (2).(3) IRONRIDGE ' IRONRIDGE 125 X 1.20• . =r 150 ' FLASHFOOT2 FLASHFOOT2 150. - 100 50AALLOWABLE BACKFEED" . (E) BUILDING (E) BUILDING STRUCTURE STRUCTURE DERATED AMPACITY OF 8 AWG CONDUCT_ OR @ 0.87 TEMPERATURE CORRECTION 55 X . 0.87 47.85 AMPS - OK - Existing composition shingle roof , T End Clamp. Photovoltaic _ i Module. 5/16" diameter 3:5" length lag screw QTY EQUIPMENT DESCRIPTION OPEN CIRCUIT VOLTAGE (Voc) : 40,05V HANWHA Q -CELL. MAX. POWER VOLTAGE (Vmp) : 32.62V, 27 Q PEAK -G4.1 305, . ' SHORT CIRCUIT CURRENT (Isc) : 9.84A 305W MODULES. MAX. POWER_ CURRENT.(Imp) : 9.35A PTC RATING: 279.2W , SOLAR EDGE MAX: DC INPUT VOLTAGE: 350V SE7600H-US MAX. AC OUTPUT VOLTAGE RANGE: 211-240V 1 MAX. AC OUTPUT CURRENT.: • 32A � WITH POWER MAX. ACPOWEROUPUT : , 7600W OPTIMIZER -CEC EFFICIENCY: 98% 1 JUNCTION BOX .1600VDC, NEMA 4X', UL LISTED 1, AC DISCONNECT 600VAC, 60A, NEMA 3R, UL LISTED 1 PV BREAKER' 2 POLE, 240V, 40.A. 42 ' ATTACHMENTS FLUSH FOOT MOUNT., 150' RAIL' 1 IRONRIDGE-XR100 IRONRIDGE XR100 GROUNDING_ ` 46 MID CLAMPS MID CLAMPS, ' .16 • END CLAMPS IRONRIDGE XR100 END CLAMPS, 40'' CONDUIT .X3/4" OR LARGER�EMT CONDUIT , ,• x Mid Clamp • ' a--_... _ '. t� j ? -t•-^r-.-r - .. _ _ � T' - ..moi-....`�•+ + - _ • --�—'i--.r-.-s.,-•,-.,_�.y..-_..+,T .. _ ._.�...,.. .....—<_ -�.. ... ,. t ..:.-..:.- •-.s--•r-+--—,.�.-_ _-^....� -. _ •_ '•• � i �• .. ~ .�' ' `�� r , •. ''. � - •~-. .y - "•' } - .. - t S-•. a �-S_ . ., + - , r s r . Existing 2" X 4.' F _ . TRUSSES @ 24" O C _ f 6"maz s , L' IronRidge per PV Support s +L "Mi ninum 2.5" Lag Screw • - .. Embedment. Photovoltaic Panel Mounting Detail .l' Scale: NTS I ��' eeaeca com,ecto,N1 ;CLIENT: REVISIONS: r TITLE: ' SHEET: " ' - • ' DATE: • 12/20/2017 ` �' C=10982892 DESCRIPTION DATE REVISION ROOF MOUNTING. • Freedor»Solar WELLS, KOLLEEN 84 CY.NTHIANN LANE, DESIGN DETAILS, ELEC. Freedom Solar Co OROVILLE, CA 95966 BY: GREG PV -4 (530) 370-6341 ' CALCULATION & 25819 Jefferson Ave; Suite 11.0, Murrieta, CA 92562 MATERIAL LIST R JOB NO.: FS -12-075 Tel: (800) 385-1075 LABELS: LABELS SPECIFICATION: 1. ALL CAPITAL LETTERS 2. MINIMUM 3/8" LETTER HEIGHT 3. ARIAL OR SIMILAR, NON -BOLD, 4. WHITE LETTERING IN RED BACKGROUND 5. WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (DURABLE ADHESIVE MATERIALS MUST MEET THIS REQUIREMENT 6. ALL SIGNS SHOULD BE REFLECTIVE 27 PV MODULE ) WITH Eledde lContmdor No: CLIENT: Freedom Solar' C-10 982892 -- Freedom Solar Co 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 Tel: (800) 385-1075 DISCONNECTION MEANS ALL AC AND DC DISCONNECTS TO BE MARKED AS DISCONNECTING MEANS PER CEC 2016 690.13(B) AC DISCONNECT PHOTOVOLTAIC DISCONNECT FOR UTILITY OPERATION INVERTER OUTPUT CONNECTION TO BE INSTALLED AT MAIN SERVICE PANEL PER CEC 2016 705.12 (D) E MARKING SHOULD BE PLACED ON ALL INTERIOR AND EXTERIOR PV CONDUIT; RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES, EVERY 10 FEET, AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS AND ALL PV COMBINER AND JUNCTION BOXES. WARNING PHOTOVOLTIC POWER SOURCE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION; TO BE INSTALLED AT DISCONNECTING MEANS PER CEC 2016 690.17 WARNING ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. PHOTOVOLTAIC POWER SOURCE SHALL BE LABELED WITH THE FOLLOWING WARNING AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT, AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE PER CEC690.35(F) WARNING ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. 1' WELLS, KOLLEEN 84 CYNTHIANN LANE, OROVILLE, CA 95966 (530)370-6341 WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE 690.12 COMPLIANT PHOTOVOLTAIC SYSTEM, EQUIPPED WITH RAPID SHUTDOWN DIRECT-CURRENT PHOTOVOLTAIC POWER SOURCE TO BE INSTALLED AT INVERTER PER CEC 690.53 OPERATING CURRENT: 17.9A OPERATING VOLTAGE: 350.06V SHORT-CIRCUIT CURRENT: 23.62A MAX SYSTEM VOLTAGE: 500.00V AC DISCONNECT PHOTOVOLTIC DISCONNECT FOR UTILITY -OPERATION WARNING ELECTRIC SHOCK HAZARD CONTACT. QUALIFIED SERVICE .PERSONNEL FOR ASSISTANCE Nominal Voltage 240 Volts Nominal AC Frequency 60 Hz Maximum AC Power 7600 Watts Maximum AC Current 40.00 Amps Max.Overcurrent Device 40 Amps Max. Current per Pole 40.00 Amps REVISIONS: DATE: 12/20/2017 DESCRIPTION DATE REVISION DESIGN BY: I GREG JOB NO.:I FS -12-075 - TITLE: SHEET: LABELS PV -5 CAUTION - POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING MAIN PANEL SOURCES WITH DISCONNECTS O LOCATED AS SHOWN Q WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL 27 PV MODULE ) WITH Eledde lContmdor No: CLIENT: Freedom Solar' C-10 982892 -- Freedom Solar Co 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 Tel: (800) 385-1075 DISCONNECTION MEANS ALL AC AND DC DISCONNECTS TO BE MARKED AS DISCONNECTING MEANS PER CEC 2016 690.13(B) AC DISCONNECT PHOTOVOLTAIC DISCONNECT FOR UTILITY OPERATION INVERTER OUTPUT CONNECTION TO BE INSTALLED AT MAIN SERVICE PANEL PER CEC 2016 705.12 (D) E MARKING SHOULD BE PLACED ON ALL INTERIOR AND EXTERIOR PV CONDUIT; RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES, EVERY 10 FEET, AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS AND ALL PV COMBINER AND JUNCTION BOXES. WARNING PHOTOVOLTIC POWER SOURCE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION; TO BE INSTALLED AT DISCONNECTING MEANS PER CEC 2016 690.17 WARNING ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. PHOTOVOLTAIC POWER SOURCE SHALL BE LABELED WITH THE FOLLOWING WARNING AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT, AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE PER CEC690.35(F) WARNING ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. 1' WELLS, KOLLEEN 84 CYNTHIANN LANE, OROVILLE, CA 95966 (530)370-6341 WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE 690.12 COMPLIANT PHOTOVOLTAIC SYSTEM, EQUIPPED WITH RAPID SHUTDOWN DIRECT-CURRENT PHOTOVOLTAIC POWER SOURCE TO BE INSTALLED AT INVERTER PER CEC 690.53 OPERATING CURRENT: 17.9A OPERATING VOLTAGE: 350.06V SHORT-CIRCUIT CURRENT: 23.62A MAX SYSTEM VOLTAGE: 500.00V AC DISCONNECT PHOTOVOLTIC DISCONNECT FOR UTILITY -OPERATION WARNING ELECTRIC SHOCK HAZARD CONTACT. QUALIFIED SERVICE .PERSONNEL FOR ASSISTANCE Nominal Voltage 240 Volts Nominal AC Frequency 60 Hz Maximum AC Power 7600 Watts Maximum AC Current 40.00 Amps Max.Overcurrent Device 40 Amps Max. Current per Pole 40.00 Amps REVISIONS: DATE: 12/20/2017 DESCRIPTION DATE REVISION DESIGN BY: I GREG JOB NO.:I FS -12-075 - TITLE: SHEET: LABELS PV -5