Loading...
HomeMy WebLinkAboutB18-0063 022-350-064•BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES INSPECTION CARD MUST BE ON JOB SITE , 24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspections is 3pm) Development Services cannot guarantee inspections on the (late requested Office: 530.538.7601 Fax: 530.538.7785 www.ButteCounty.neddds Permit No: 1318-0063 Issued: 1/10/2018 APN: 022-350-064 Address: 445 TRENT ST, BIGGS Owner:'. RODRIGUEZ JOSE & DORA Permit Type: SOLAR ROOF -RES Description: Installation of 5.04 kw PV Solar System AREA 1 • ' - Flood Zone: X (Shade SRA Area: LRA SETBACKS for Zoniniz. AG. SRA. PW Front: Centerline of Road: Rear: SRA: ' Street: AG: Interior ' Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING { Inspection Type IVR INSP DATE Setbacks 131 Foundations / Footings 1 I 1 Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Signed Pre -Slab 124 Gas.Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 Blockin /Under inin 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed Shearwall/B.W.P.-Interior 134 Shearwall/B.W.P.-Exterior 135 RoofNail/Drag Trusses 129 417 Manometer Test Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing, 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulaie Until Above Signed Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Plumbing Final 813 Fire Sprinkler Test or Final 702 Swimming Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -.Deck 505 Pool Fencing/Alarms/Barriers 503 Pre -Plaster 507 Manufactured Homes Setbacks 131 Blockin /Under inin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Underground Electric 218 Sewer 407 Under round Water 417 Manometer Test 605 Continuity Test 602 Skirting/Steps/Landings 610 Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: Length x Width: Insignia: w - ;,..� r:� 1. .. F,in�als, 7 Permit Final 802 Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test or Final 702 Public Works Final 538.7681 Fire De artrnent/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final ,*PROJECT FINAL i I RW *Project Final is a Certificate of 0ecupancy for (Residential OnhY) PERA91rS BECO\lE NULL AND VOID I YE -All FRONT THE: DATE OF ISSUANCE. IF WORK HAS CO,YI:ME-LACED, YOU ,NIA1' PAY 1-011 A I YEAR RENS-LAVAL 30 DAYS 1'121012 TO EXPIRATION - Y' _PV 1.0 COVER PV 2.0 y SITE PLAN PV 3.0�- ROOF PLAN ; Dora Rodrigues 'LOCATION NOTES PV 5.0 MOUNTING DETAILS +r. ••t 'SYSTEM LABELS EL 1.0 ' ONE -LINE DIAGRAM ` EL 2.0 ' � r445 TRENT ST ]. a , - • 'BIGGS, CA 959170.+, - �' . �: -� t . • { ' . 1 Y{ R F lG t. y„ •r,, iii � 0 o {�'�,.'� _� �+• � '+' • • r '`Z ., � ..� 'y� �yf,'��' _ .. .• `� +, r •+ .'s , ' O �• -y--• �j',x, + • � • �'' �-.� _ _ � r.:�� .fir � _` t _ �� , � f . � T - ] 4 SATELLITE IMAGE + r' -s TABLE OF_ CONTENTS , _PV 1.0 COVER PV 2.0 y SITE PLAN PV 3.0�- ROOF PLAN ; PV 4.0 'LOCATION NOTES PV 5.0 MOUNTING DETAILS +r. PV 6.0 'SYSTEM LABELS EL 1.0 ' ONE -LINE DIAGRAM ` EL 2.0 ' ELECTRICAL -NOTES SCOPE OF WORK:.i THE SYSTEM CONSISTS OF A 4.76 KW. DC (3.91 KW AC) ROOF -MOUNTED PHOTOVOLTAIC POWER SYSTEM OPERATING IN, .PARALLEL WITH THE UTILITY GRIDI..THERE ARE (17) HYUNDAI HIS-S280RG(BK)• MODULES AND (17) ENPHASE IQ6-60-2-US • ::. MICRO -INVERTERS; .CONNECTING TO THE UTILITY GRID , THROUGH THE EXISTING MAIN LOAD CENTER. ELECTRICAL= =. MODIFICATIONS WILL BE, MADE TO sTHE MAIN LOAD CENTER. INTERCONNECTION'METHOD LOAD -SIDE BREAKER, ROOF MATERIAL:. Composite Shingle PROJECT WILL. COMPLY WITH THE 20.16 CRC;, 2016. CEC; 20116 CBC, AND 2016 CFC, 2015 IRC;•2014- NEC; 2015 IBC; 2015 IFC.--.' 'r r CONTRACTOR: SUNFINITY SOLAR -CA LLC i, 4612 ROSEVILLE ROAD, SUITE 112 r _ { .. _ r , _ • SACRAMENTO, CA 95660 T _ ' ',. ' t: , • r ; LICENSE NO. 1013931 41. 1, nnn y a • <: - - "� : , �- SOL—: SHEET: DESIGNER' _ DATE CREATED: COVER �._ . • _ - * — _ J. Larson 1/29/2018 rPV 1.0 SCALE: UTILITY METER LOCATION MAIN SERVICE LOCATION/ = L POINT OF INTERCONNECTION BIGGS PRODUCTION METER AC DISCONNECT SWITCH ENVOY IQ COMBINER PANEL ®-Circuit 1 ® - Circuit 2 PV SYSTEM SIZE: 4.76 kW DC 3.91 kW AC 17 MODULES *ROMEX WILL BE RAN THROUGH THE ATTIC WHERE POSSIBLE *ALL CONDUIT WILL BE PAINTED TO MATCH THE EXISTING STRUCTURE i . 1 / 1 v 1VlVL A -i,3 _. 445 TRENT ST BIGGS, CA 95917 SCALE:. :. ROOF/PLUMBING VENTS MECHANICAI. FASTENINGIMOUNTING IRON RIDGE XR 100 RAILS REFER TO PAGE 5 FOR SECTION DETAIL'& ATTACHMENT INFO. t o a n ROOF SECTION A ; MODULES 17 TILT 19 AZIMUTH 180 SOLAR ACCESS AVG. 100.00% WEATHER DATA HIGH TEMP, 2% AVG. 38 °C MIN DESIGN TEMP -3 °C GROUND SNOW LOAD "0 psf WIND SPEED 110 mph VENTS IN ACCORDANCE WITH CPC 901.1, CPC ` MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION FROM 2009 ASHRAE HANDBOOK - FUNDAMENTALS 1. HIGH TEMPERATURE 2% AVERAGE BASED ON ASHRAE HIGHEST 8. PV INSTALLATION SHALL NOT OBSTRUCT ANY MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION PLUMBING VENTS, MECHANICAL EQUIPMENT, MOST SIMILAR TO INSTALLATION LOCATION MECHANICAL VENTS, OR BUILDING ROOF 2. MINIMUM DESIGN TEMPERATURE BASED ON ASHRAE MINIMUM. VENTS IN ACCORDANCE WITH CPC 901.1, CPC ` MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION 906; AND CMC 304. MOST SIMILAR TO INSTALLATION LOCATION 9. CONNECTORS THAT ARE NOT READILY 3 ALTERNATE POWER SOURCE PLACARD SHALL BE PERMANENTLY ACCESSIBLE AND THAT ARE USED IN THE ATTACHED TO A/C DISCONNECT. CIRCUITS OPERATING AT OR OVER 30V AC OR 4.., ELECTRICAL INSTALL SHALL COMPLY WITH 2016 CALIFORNIA DC SHALL REQUIRE A TOOL FOR OPERATING ELECTRICAL CODE (INCLUDING AN "ALTERNATE POWER SOURCE AND ARE REQUIRED TO BE MARKED "DO NOT PLACARD") DISCONNECT UNDER LOAD" OR "NOT FOR h 5. ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS CURRENT INTERRUPTING" SHALL BE BONDED 10. THIS SYSTEM IS IN FULL COMPLIANCE WITH 6. IF THE EXISTING MAIN SERVICE DOES NOT HAVE VERIFIABLE THE CALIFORNIA FIRE CODE FOR GROUNDING ELECTRODE, IT IS THE PV CONTRACTOR'S PHOTOVOLTAIC INSTALLATION AND ARTICLE ` RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING 690 OF THE NATIONAL ELECTRIC CODE (NEC ' ELECTRODE NFPA 70) 7. EACH MODULE SHALL BE GROUNDED PER MANUFACTURER 11. BUILDING CONSTRUCTION TYPE: TYPE V INSTRUCTIONS AND APPROVED METHODS - 12. BUILDING OCCUPANCY TYPE: R3 w r .. - a r - � � � C w PHOTOVOLTAIC DC DISCONNECT CEC 690.14 (C)(2) LOCATED ON THE DC DISCONNECT PORTION OF THE INVERTER (FOR STRING INVERTERS, NOT APPLICABLE TO MICRO -INVERTERS) PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN MICRO -INVERTERS SERVE AS RAPID SHUTDOWN DEVICES AT MODULE LEVEL CEC 690.56 (B) & (C) LOCATED ON THE AC DISCONNECT AND ALL JUNCTION BOXES AT ARRAY LEVEL THIS PV SYSTEM WILL HAVE THE FOLLOWING MARKINGS: PHOTOVOLTAIC AC DISCONNECT RAPID SHUTDOWN SWITCH WARNING: DUAL POWER SOURCES THIS EQUIPMENT FED BY MULTIPLE SOURCES SECOND SOURCE IS PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT AMPS AC NORMAL OPERATING VOLTAGE VOLTS CEC 690.54 & CEC 705.12(D)(7) PLACE ON MAIN SERVICE PANEL AND ON SOLAR PV COMBINER PANELBOARD CEC 690.14 (C)(2) LOCATED ON THE AC DISCONNECT PV SYSTEM AC DISCONNECT SECOND SOURCE IS PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT AMPS AC NORMAL OPERATING VOLTAGE VOLTS CEC 690.54 PLACED NEXT TO THE SOLAR PV BREAKER AND ON AC DISCONNECT WARNING: PHOTOVOLTAIC POWER SOURCE CRC R331.2 PLACED ALONG DIRECT CURRENT CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES, AND JUNCTION BOXES WARNING: ELECTRIC SHOCK HAZARD GROUNDED CONDUCTORS MAY BECOME UNGROUNDED AND ENERGIZED IF A GROUND FAULT IS INDICATED CEC 690.5 (C) PLACED ON ALL INVERTERS AND JUNCTION BOXES, OR PLACED NEAR THE GROUND -FAULT INDICATOR AT A VISIBLE LOCATION PHOTOVOLTAIC SYSTEMS AC SYSTEM SPECIFICATIONS SYSTEM SIZE: KW COMBINED OPERATING RATING:.. AMPS RATED OUTPUT VOLTAGE: VAC CEC 690.17 & CEC 690.54 LOCATED ON MAIN SERVICE PANEL WARNING: ELECTRIC SHOCK HAZARD MICRO -INVERTER PHOTOVOLTAIC SYSTEM DC CONDUCTORS OF PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED j CEC 690.35 (F) PLACED ON ALL INVERTERS, JUNCTION BOXES AND SOLAR PV COMBINER PANELBOARD WARNING: ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION CEC 690.17 & CEC 690.54 PLACED ON OR ADJACENT TO THE AC DISCONNECT AND DISCONNECTING MEANS (SOLAR PV BREAKER) WARNING: INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE CEC 705.12 (D)(7) PLACED NEXT TO THE SOLAR PV BREAKER ON THE MAIN SERVICE PANEL, AND ON THE SOLAR PV COMBINER PANELBOARD 1 -- MATERIALS USED FOR MARKINGS WILL BE WEATHER RESISTANT. THE UNDERWRITERS LABORATORIES MARKING AND LABELING SYSTEM 969 (UL969) WILL BE USED AS STANDARD TO DETERMINE WEATHER RATING. ' 2 -- MARKING STATING "CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED" WILL BE PLACED AT THE MAIN SERVICE DISCONNECT. 3-- MARKING STATING "WARNING: PHOTOVOLTAIC POWER SOURCE" WILL BE PLACED ALONG DIRECT CURRENT CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES, AND JUNCTION BOXES. 4-- THE MARKING WILL BE MADE TO THE FOLLOWING SPECIFICATIONS: • RED BACKGROUND t . • WHITE LETTERING • MINIMUM 3/8" LETTER HEIGHT in • ALL CAPITAL LETTERS�,' u, • ARIAL OR SIMILAR FONT, NON -BOLD $ �' R - • REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (DURABLE ADHESIVE MATERIALS MAY MEET THIS REQUIREMENT) w SHEET: D 5-- MARKING WILL BE PLACED ON ALL INTERIOR AND EXTERIOR CONDUIT, RACEWAYS, ENCLOSURES, CABLE -ASSEMBLIES, AND JUNCTION BOXES TO ALERT THE FIRE SERVICE TO AVOID CUTTING THEM. LABELING MARKINGS WILL BE PLACED ON ALL EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES EVERY 10 FEET, AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS AND ALL DC COMBINER AND JUNCTION BOXES. PV 6.0 PV1V..,.,. , . .. MICRO -INVERTER ATTACHED. INVERTER COMPLIES WITH RAPID SHUTDOWN REQUIREMENTS AS OUTLINED IN CEC 690.12. PV MODULE SPECIFICATIONS MODULE MAKE AND MODEL HYUNDAI HIS-S280RG(BK) MAXIMUM POWER (DC) 280 WATTS MAX POWER -POINT VOLTAGE (VMPP) 31.7 VOLTS MAX POWER -POINT CURRENT (IMPP) 8.70 AMPS OPEN CIRCUIT VOLTAGE (VOC) 38.5 VOLTS SHORT CIRCUIT CURRENT (ISC) 9.4 AMPS TEMPERATURE COEFFICIENT VOC -0.42 %/°C MAXIMUM SYSTEM VOLTAGE 1000V DC (UL) THWN-2 OR NM (ROMEX) (EGC,GEC) PV CIRCUIT 1: 9 MODULES/PARALLEL PV CIRCUIT 2: 8 MODULES/PARALLEL M AC PHOTOVOLTAIC SYSTEM RATINGS MAX AC OPERATING CURRENT 16.32 AMPS MAX AC OPERATING VOLTAGE 240 VOLTS *ROMEX WILL BE RAN THROUGH THE ATTIC WHERE POSSIBLE 4.76 kW DC 3.91 kW AC 17 MODULES MICRO -INVERTER SPECIFICATIONS INVERTER MAKE AND MODEL ENPHASE IQ6-60-2-US RATED OUTPUT POWER (AC) 230 WATTS NOMINAL OUTPUT VOLTAGE -(AC) 240 VOLTS MAX OUTPUT CURRENT (AC) 0.96 AMPS MAX INPUT VOLTAGE (DC) 48 VOLTS MAX INPUT CURRENT (DC) 15 AMPS MAX OCPD RATING (AC) 20 AMPS MAX NUMBER OF PANELS PER CIRCUIT 16 THWN-2 OR NM (ROMEX) (EGC,GEC) COMBINER PANEL VISIBLE LOCKABLE "KNIFE" A/C ENVOY IQ 125A/240V DISCONNECT 30A/240V (DRAWS 0.22 AMPS) 20A BIGGS PRODUCTION METER 20A M 20 A A / A JUNCTION BOX LOCATED ON ROOF A B GROUNDING WIRE ADDITIONAL ROOFTOP DISCONNECT NOT REQUIRED. ENPHASE MICROINVERTER CABLE CONNECTORS MEET DISCONNECT REQUIREMENTS. CEC 690.33 dol U U- EXISTING 240V/200A BUS -BAR RATED - LOAD -CENTER (CENTER FED) PANEL. BREAKER WILL BE FURTHEST POSITION AWAY FROM DISCONNECT. 445 TRENT ST BIGGS, CA 95917 200 RACEWAY AND CONDUCTOR SCHEDULE TAG CONDUCTOR TYPE NIlNIMUM WIRE SIZE # OF CONDUCTORS RACEWAY / CABLE TYPE MIND" CONDUIT SIZE A ENPHASE ENGAGE CABLE (USE -2) 12 2 USE -2 / FREE AIR N/A BARE COPPER (EGC/GEC) 6 1 BARE / FREE AIR B THWN-2 OR NM (ROMEX) * 10 4 EMT / ROMEX 3/4" THWN-2 OR NM (ROMEX) (EGC,GEC) 8 1 C THWN-2 OR NM (ROMEX) * 10 3 EMT / ROMEX 3/4" THWN-2 OR NM (ROMEX) (EGC/GEC) 10 1 *ALL CONDUIT WILL BE PAINTED TO MATCH THE EXISTING STRUCTURE. AC DISCONNECT LOCATED NEXT TO OR WITHIN 10 FEET OF MAIN SERVICE PANEL (LINE OF SIGHT MAINTAINED). DESIGN WILL UTILIZE INTEGRATED GROUNDING BETWEEN PV MODULES AND RACKING ENVOY -S METER POWERED BY PV SYSTEM, PROTECTED BY 15A OCPD LOCATED IN 125A COLLECTION PANEL PERMANENT PLAQUES LABELED "PV RAPID SHUTDOWN' WILL BE INSTALLED ADJACENT TO THE VISIBLE LOCKABLE A/C DISCONNECT AND ON ARRAY JUNCTION BOXES S � :fors SHEET: 1 -LINE DIAGRAM EL 1.0 1. THE ENPHASE IQ6-60-2-US MICROINVERTERS MEET THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE ARTICLE 690.35 FOR UNGROUNDED PHOTOVOLTAIC POWER SYSTEMS. NEC 690.35 ALLOWS FOR PHOTOVOLTAIC POWER SYSTEMS TO BE INSTALLED WITH UNGROUNDED PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS. SYSTEMS THAT MEET THE REQUIREMENTS OF NEC 690.35 ARE EXEMPT FROM THE SYSTEM GROUNDING REQUIREMENTS OF NEC 690.41.SYSTEM GROUNDING. 2. NEC ARTICLE 690.43 EQUIPMENT GROUNDING SPECIFIES THAT ALL EXPOSED NON -CURRENT -CARRYING METAL PARTS OF PV MODULE FRAMES, + ELECTRICAL EQUIPMENT, AND CONDUCTOR ENCLOSURES SHALL BE PROVIDED WITH EQUIPMENT GROUNDING. 690.43(C) STRUCTURE AS EQUIPMENT GROUNDING CONDUCTOR ALLOWS FOR EQUIPMENT TO BE USED AS THE EQUIPMENT GROUNDING CONDUCTOR IN A PHOTOVOLTAIC SYSTEM. SPECIFICALLY, "DEVICES LISTED AND IDENTIFIED FOR GROUNDING THE METALLIC FRAMES OF PV MODULES OR OTHER EQUIPMENT SHALL BE PERMITTED TO BOND THE EXPOSED METAL SURFACES OR OTHER EQUIPMENT TO MOUNTING SURFACES." THE DEVICES LISTED AND IDENTIFIED FOR GROUNDIN&THE EQUIPMENT MAY BE STAND-ALONE GROUNDING COMPONENTS OR UL -2703 LISTED MOUNTING HARDWARE. IN AN ENPHASE MICROINVERTER SYSTEM, IF THE MICROINVERTERS AND MODULES ARE BONDED TO THE RACKING ASSEMBLIES WITH THE USE OF LISTED AND APPROVED GROUNDING CLIPS OR GROUNDING COMPONENTS, THE EQUIPMENT GROUNDING CONDUCTOR PROVIDED TO THE MICROINVERTERS THROUGH THE ENPHASE ENGAGE CABLE MAY ALSO BE USED TO GROUND THE OTHER PHOTOVOLTAIC SYSTEM COMPONENTS. did IR.ONRID_GE XRRail,Farnilyi xR:Rau Famiiy; e • TIi13.XR Rall FarnOyoffers the strertgtfl 01 a curried r211 to thjee targeted sizes%Each slze`supparts spt3oifia# - _ n .Bre x , sSokFIs N6 AIways Sunny: -- - - _ _,_.. _- �h.:..1s -. deslgnaoads while rttfnimliing material Costs. Depending on your Ilicatfo an R Rall io metiihi . Overtheir UIij?,�solar panels etcpenence countless � t ; extreme weather events Nol Just the worse storms'Irt ye@rs; •,,but the worst stormsa`n 40 years High winds capable o; � _ • _ _ _ - ,�...:'- � - - - _ _ - - ' b ripping panels from a rcpt, andsnoM#lls:weighing enough tp buckle's panel frame" • ('XRRalls ara,;�he structural backbone preventing; .-these results They resisluphft; protect 1 ti !4%A10)' - tXiii00, fxA1000 against buckling,and: safely and y: ethctenll` - .XiitD l�asleok,.lw,-Pronbma,rinrpc xRtoo,ldme ublmme maidemla! 't ,xRr000 rs•e rieowytrelgM dmons- - ' ,transfer loads Into the bulldlrig: structure qr t r�14 a tea roi r�lons Y ui; lierdm 1 mo w� ra h 9,aPau n'ronR of, soar moumrla reps q d,ln to Iii ori t Their superior spanning capability i rp crow h mmiews s root spa ts: w nne, wind end snow crond0kine krone obo W omB cgme[es and ePari iz ter ta.. ' ,. s , rometring Ilght mtd,dmrfomlml.l mm�kr nd s! 'W RO cP to a tdot:• + moro for mxvnmdol o{�Ifcofloiis , , + ; j � requires fewer root.attachments, t -- • -,,.y ,• • - .. _ _ - - reducinglhenumberofrooi - � `� r f a p'>�+I�re�P�4+r.. , ,� soP?�±!+rreiry ';+r�+reIb - • t penetrallons'rid the amount t _ ; Moderato load,eapaLlilb ifeaoq wad oapaLlWy"; r.� erdrome and ca�anlry - * ` t .. -.., . - Cloar 8 block anodlmd flntah i- t Cloei 8 bladt arodtzo0 nnffih I - ,:Clearand9xod nnUh - �b1 Installation time � • r1 r ,JJ��1•�,,� .� �� � � • t I�r� stamov arailetiiu � mrmnitil:spnma wa➢adrle _' tnrenraf aPOees pvSnable - " - � r � I � Rate -Selection. � " _ •• „ 47tte following tattle was preparedin,cfimpilanoewfthspplicable ongineeiirtg odes.t nd standards Values are, . based'on the followln` criteria ASCE.7.10 Roof Zone 1 .;Exposure 6, Ropi Sldof 711 27 ` tees and Meati= Buil611i8 9 htNel 'ot 30 f£ Malt IronHfd s.00m for daCailed s _ — i . a - �,• r 9 hon tables and`ceittfli:atians:: . Force-Stsbffizfng Curve' r,� s ; � Sloped roots gentfmW DdRl komcal edGlntdml ! i r0lLES-are rratimmB rads vdtkft can cause umm y t' • � t lo,borjd arui twra1.71io euxw! sliaRo of XR Roll's 1 'r•.. - s soe®Ily ddslm,ad to ftxT e.slm rfth h boli ! ,, - dheplOnS Yldb rosletlng rho nYhdh+g TtdII'onlquo - - • ! . rtF- � - s tectum enSureS groater tmcufiy duAng etltmmW i .s woodier and'e tdtfgw eYaOcn! uleUma _ , i .Compat(bte.m;6,at &Pitched hoofs; Corrosfon`:Resistant Wteridls:; s xR Rafts arp�,,, . ; tronRkrgo Olfq`m` AII,XR Rfiks ora madp o18000-^eri0s ;�e., ` i Cotrtpabhtawitk r 4 ON ei �oerpaoroomoug rsruuraaormson, e L*plgvi 4""up{iltcaflons: 'e iriore ottrective eppeemrice; t q E ". � 1001 -- XR10 jF ltR_ 1110..; _ • f_tM_000 1401 I i 56 1m; 180;. r I160;