HomeMy WebLinkAboutB18-0063 022-350-064•BUTTE COUNTY
DEPARTMENT OF DEVELOPMENT SERVICES
INSPECTION CARD MUST BE ON JOB SITE ,
24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspections is 3pm)
Development Services cannot guarantee inspections on the (late requested
Office: 530.538.7601 Fax: 530.538.7785 www.ButteCounty.neddds
Permit No: 1318-0063 Issued: 1/10/2018
APN: 022-350-064
Address: 445 TRENT ST, BIGGS
Owner:'. RODRIGUEZ JOSE & DORA
Permit Type: SOLAR ROOF -RES
Description: Installation of 5.04 kw PV Solar System
AREA
1 • ' -
Flood Zone: X (Shade SRA Area: LRA
SETBACKS for Zoniniz. AG. SRA. PW
Front: Centerline of Road:
Rear: SRA: '
Street: AG:
Interior '
Total Setback from Centerline of Road:
ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING
{
Inspection Type
IVR INSP DATE
Setbacks
131
Foundations / Footings
1 I 1
Pier/Column Footings
122
Eufer Ground
216
Masonry Grout
120
Setbacks
131
Do Not Pour Concrete Until Above are Signed
Pre -Slab
124
Gas.Test Underground/floor
404
Gas Piping Underground/floor
403
Underfloor Framing
149
Underfloor Ducts
319
Shear Transfer
136
Under Floor Plumbing
412
Under Slab Plumbing
411
Blockin /Under inin
612
Tiedown/Soft Set System
611
Do Not Install Floor Sheathing or Slab Until Above Signed
Shearwall/B.W.P.-Interior
134
Shearwall/B.W.P.-Exterior
135
RoofNail/Drag Trusses
129
417
Manometer Test
Do Not Install Siding/Stucco or Roofing Until Above Signed
Rough Framing
153
Rough Plumbing
406
Rough Mechanical
316
Rough Electrical
208
4 -Way Rough Framing,
128
Gas Piping House
403
Gas Test House
404
Shower Pan/Tub Test
408
Do Not Insulaie Until Above Signed
Inspection Type
IVR INSP DATE
T -Bar Ceiling
145
Stucco Lath
142
Plumbing Final
813
Fire Sprinkler Test or Final
702
Swimming
Pools
Setbacks
131
Pool Plumbing Test
504
Gas Test
404
Pre-Gunite
506
Pre -.Deck
505
Pool Fencing/Alarms/Barriers
503
Pre -Plaster
507
Manufactured Homes
Setbacks
131
Blockin /Under inin
612
Tiedown/Soft Set System
611
Permanent Foundation System
613
Underground Electric
218
Sewer
407
Under round Water
417
Manometer Test
605
Continuity Test
602
Skirting/Steps/Landings
610
Coach Info
Manufactures Name:
Date of Manufacture:
Model Name/Number:
Serial Numbers:
Length x Width:
Insignia:
w -
;,..� r:� 1. ..
F,in�als, 7
Permit Final
802
Electrical Final
803
Mechanical Final
809
Plumbing Final
813
Fire Sprinkler Test or Final
702
Public Works Final 538.7681
Fire De artrnent/CDF 538.6226
Env. Health Final 538.7281
Sewer District Final
,*PROJECT FINAL i I RW
*Project Final is a Certificate of 0ecupancy for (Residential OnhY)
PERA91rS BECO\lE NULL AND VOID I YE -All FRONT THE: DATE OF ISSUANCE. IF WORK HAS CO,YI:ME-LACED, YOU ,NIA1' PAY 1-011 A I YEAR
RENS-LAVAL 30 DAYS 1'121012 TO EXPIRATION -
Y'
_PV 1.0
COVER
PV 2.0
y SITE PLAN
PV 3.0�-
ROOF PLAN ;
Dora Rodrigues
'LOCATION NOTES
PV 5.0
MOUNTING DETAILS +r.
••t
'SYSTEM LABELS
EL 1.0 '
ONE -LINE DIAGRAM `
EL 2.0
' �
r445
TRENT ST ].
a ,
- • 'BIGGS, CA 959170.+, -
�' . �: -� t . • { '
.
1
Y{ R
F lG
t.
y„
•r,, iii �
0 o
{�'�,.'� _�
�+•
� '+' • •
r
'`Z .,
�
..� 'y� �yf,'��'
_ ..
.• `� +, r
•+ .'s , '
O
�• -y--• �j',x,
+
•
� •
�'' �-.�
_ _ �
r.:��
.fir
�
_`
t _ �� , � f . �
T - ] 4
SATELLITE IMAGE
+ r'
-s
TABLE OF_ CONTENTS ,
_PV 1.0
COVER
PV 2.0
y SITE PLAN
PV 3.0�-
ROOF PLAN ;
PV 4.0
'LOCATION NOTES
PV 5.0
MOUNTING DETAILS +r.
PV 6.0
'SYSTEM LABELS
EL 1.0 '
ONE -LINE DIAGRAM `
EL 2.0
' ELECTRICAL -NOTES
SCOPE OF WORK:.i
THE SYSTEM CONSISTS OF A 4.76 KW. DC (3.91 KW AC)
ROOF -MOUNTED PHOTOVOLTAIC POWER SYSTEM OPERATING IN,
.PARALLEL WITH THE UTILITY GRIDI..THERE ARE (17) HYUNDAI
HIS-S280RG(BK)• MODULES AND (17) ENPHASE IQ6-60-2-US • ::.
MICRO -INVERTERS; .CONNECTING TO THE UTILITY GRID ,
THROUGH THE EXISTING MAIN LOAD CENTER. ELECTRICAL= =.
MODIFICATIONS WILL BE, MADE TO sTHE MAIN LOAD CENTER.
INTERCONNECTION'METHOD LOAD -SIDE BREAKER,
ROOF MATERIAL:. Composite Shingle
PROJECT WILL. COMPLY WITH THE 20.16 CRC;, 2016. CEC; 20116
CBC, AND 2016 CFC, 2015 IRC;•2014- NEC; 2015 IBC; 2015 IFC.--.' 'r
r
CONTRACTOR:
SUNFINITY SOLAR -CA LLC
i, 4612
ROSEVILLE ROAD, SUITE 112
r _ { .. _ r , _ • SACRAMENTO, CA 95660
T _ ' ',. ' t: , • r ; LICENSE NO. 1013931
41.
1, nnn
y a • <: - - "� : , �- SOL—:
SHEET:
DESIGNER' _ DATE CREATED: COVER
�._ . • _ - * — _ J. Larson 1/29/2018 rPV 1.0
SCALE:
UTILITY METER LOCATION
MAIN SERVICE LOCATION/
= L
POINT OF INTERCONNECTION
BIGGS PRODUCTION METER
AC DISCONNECT SWITCH
ENVOY IQ
COMBINER PANEL
®-Circuit 1
® - Circuit 2
PV SYSTEM SIZE:
4.76 kW DC
3.91 kW AC
17 MODULES
*ROMEX WILL BE RAN THROUGH THE
ATTIC WHERE POSSIBLE
*ALL CONDUIT WILL BE PAINTED TO
MATCH THE EXISTING STRUCTURE
i
. 1 / 1 v 1VlVL A -i,3 _.
445 TRENT ST
BIGGS, CA 95917
SCALE:. :.
ROOF/PLUMBING VENTS
MECHANICAI. FASTENINGIMOUNTING
IRON RIDGE XR 100 RAILS REFER TO PAGE 5 FOR SECTION
DETAIL'& ATTACHMENT INFO.
t o a n
ROOF SECTION
A
;
MODULES
17
TILT
19
AZIMUTH
180
SOLAR ACCESS AVG.
100.00%
WEATHER DATA
HIGH TEMP, 2% AVG.
38 °C
MIN DESIGN TEMP
-3 °C
GROUND SNOW LOAD
"0 psf
WIND SPEED
110 mph
VENTS IN ACCORDANCE WITH CPC 901.1, CPC `
MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION
FROM 2009 ASHRAE HANDBOOK - FUNDAMENTALS
1. HIGH TEMPERATURE 2% AVERAGE BASED ON ASHRAE HIGHEST
8. PV INSTALLATION SHALL NOT OBSTRUCT ANY
MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION
PLUMBING VENTS, MECHANICAL EQUIPMENT,
MOST SIMILAR TO INSTALLATION LOCATION
MECHANICAL VENTS, OR BUILDING ROOF
2. MINIMUM DESIGN TEMPERATURE BASED ON ASHRAE MINIMUM.
VENTS IN ACCORDANCE WITH CPC 901.1, CPC `
MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION
906; AND CMC 304.
MOST SIMILAR TO INSTALLATION LOCATION
9. CONNECTORS THAT ARE NOT READILY
3 ALTERNATE POWER SOURCE PLACARD SHALL BE PERMANENTLY
ACCESSIBLE AND THAT ARE USED IN THE
ATTACHED TO A/C DISCONNECT. CIRCUITS OPERATING AT OR OVER 30V AC OR
4.., ELECTRICAL INSTALL SHALL COMPLY WITH 2016 CALIFORNIA DC SHALL REQUIRE A TOOL FOR OPERATING
ELECTRICAL CODE (INCLUDING AN "ALTERNATE POWER SOURCE AND ARE REQUIRED TO BE MARKED "DO NOT
PLACARD") DISCONNECT UNDER LOAD" OR "NOT FOR h
5. ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS CURRENT INTERRUPTING"
SHALL BE BONDED 10. THIS SYSTEM IS IN FULL COMPLIANCE WITH
6. IF THE EXISTING MAIN SERVICE DOES NOT HAVE VERIFIABLE THE CALIFORNIA FIRE CODE FOR
GROUNDING ELECTRODE, IT IS THE PV CONTRACTOR'S PHOTOVOLTAIC INSTALLATION AND ARTICLE `
RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING 690 OF THE NATIONAL ELECTRIC CODE (NEC '
ELECTRODE NFPA 70)
7. EACH MODULE SHALL BE GROUNDED PER MANUFACTURER 11. BUILDING CONSTRUCTION TYPE: TYPE V
INSTRUCTIONS AND APPROVED METHODS - 12. BUILDING OCCUPANCY TYPE: R3
w
r ..
-
a r - � �
� C
w
PHOTOVOLTAIC
DC DISCONNECT
CEC 690.14 (C)(2)
LOCATED ON THE DC DISCONNECT PORTION OF
THE INVERTER (FOR STRING INVERTERS, NOT
APPLICABLE TO MICRO -INVERTERS)
PHOTOVOLTAIC SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
MICRO -INVERTERS SERVE AS RAPID
SHUTDOWN DEVICES AT MODULE
LEVEL
CEC 690.56 (B) & (C)
LOCATED ON THE AC DISCONNECT AND ALL
JUNCTION BOXES AT ARRAY LEVEL
THIS PV SYSTEM WILL HAVE THE FOLLOWING MARKINGS:
PHOTOVOLTAIC
AC DISCONNECT
RAPID SHUTDOWN
SWITCH
WARNING: DUAL POWER SOURCES
THIS EQUIPMENT FED BY MULTIPLE SOURCES
SECOND SOURCE IS PHOTOVOLTAIC SYSTEM
RATED AC OUTPUT CURRENT AMPS AC
NORMAL OPERATING VOLTAGE VOLTS
CEC 690.54 & CEC 705.12(D)(7)
PLACE ON MAIN SERVICE PANEL AND ON SOLAR PV
COMBINER PANELBOARD
CEC 690.14 (C)(2)
LOCATED ON THE AC DISCONNECT
PV SYSTEM AC DISCONNECT
SECOND SOURCE IS PHOTOVOLTAIC SYSTEM
RATED AC OUTPUT CURRENT AMPS AC
NORMAL OPERATING VOLTAGE VOLTS
CEC 690.54
PLACED NEXT TO THE SOLAR PV BREAKER AND ON
AC DISCONNECT
WARNING: PHOTOVOLTAIC POWER SOURCE
CRC R331.2
PLACED ALONG DIRECT CURRENT CONDUIT, RACEWAYS,
ENCLOSURES, CABLE ASSEMBLIES, AND JUNCTION BOXES
WARNING: ELECTRIC SHOCK HAZARD
GROUNDED CONDUCTORS MAY BECOME
UNGROUNDED AND ENERGIZED IF A GROUND
FAULT IS INDICATED
CEC 690.5 (C)
PLACED ON ALL INVERTERS AND JUNCTION
BOXES, OR PLACED NEAR THE GROUND -FAULT
INDICATOR AT A VISIBLE LOCATION
PHOTOVOLTAIC SYSTEMS
AC SYSTEM SPECIFICATIONS
SYSTEM SIZE: KW
COMBINED OPERATING RATING:.. AMPS
RATED OUTPUT VOLTAGE: VAC
CEC 690.17 & CEC 690.54
LOCATED ON MAIN SERVICE PANEL
WARNING: ELECTRIC SHOCK HAZARD
MICRO -INVERTER PHOTOVOLTAIC SYSTEM
DC CONDUCTORS OF PHOTOVOLTAIC
SYSTEM ARE UNGROUNDED AND MAY BE
ENERGIZED j
CEC 690.35 (F)
PLACED ON ALL INVERTERS, JUNCTION
BOXES AND SOLAR PV COMBINER
PANELBOARD
WARNING: ELECTRIC SHOCK HAZARD
DO NOT TOUCH TERMINALS
TERMINALS ON BOTH THE LINE AND
LOAD SIDE MAY BE ENERGIZED IN THE
OPEN POSITION
CEC 690.17 & CEC 690.54
PLACED ON OR ADJACENT TO THE AC DISCONNECT
AND DISCONNECTING MEANS (SOLAR PV BREAKER)
WARNING:
INVERTER OUTPUT CONNECTION
DO NOT RELOCATE THIS OVERCURRENT
DEVICE
CEC 705.12 (D)(7)
PLACED NEXT TO THE SOLAR PV BREAKER ON THE
MAIN SERVICE PANEL, AND ON THE SOLAR PV
COMBINER PANELBOARD
1 -- MATERIALS USED FOR MARKINGS WILL BE WEATHER RESISTANT. THE UNDERWRITERS LABORATORIES MARKING AND LABELING SYSTEM 969 (UL969) WILL BE USED AS STANDARD TO DETERMINE
WEATHER RATING. '
2 -- MARKING STATING "CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED" WILL BE PLACED AT THE MAIN SERVICE DISCONNECT.
3-- MARKING STATING "WARNING: PHOTOVOLTAIC POWER SOURCE" WILL BE PLACED ALONG DIRECT CURRENT CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES, AND JUNCTION BOXES.
4-- THE MARKING WILL BE MADE TO THE FOLLOWING SPECIFICATIONS:
• RED BACKGROUND t .
• WHITE LETTERING
• MINIMUM 3/8" LETTER HEIGHT in
• ALL CAPITAL LETTERS�,' u,
• ARIAL OR SIMILAR FONT, NON -BOLD
$ �' R -
• REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (DURABLE ADHESIVE MATERIALS MAY MEET THIS REQUIREMENT) w
SHEET: D
5-- MARKING WILL BE PLACED ON ALL INTERIOR AND EXTERIOR CONDUIT, RACEWAYS, ENCLOSURES, CABLE -ASSEMBLIES, AND JUNCTION BOXES TO ALERT THE FIRE SERVICE TO AVOID CUTTING THEM. LABELING
MARKINGS WILL BE PLACED ON ALL EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES EVERY 10 FEET, AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS AND ALL DC
COMBINER AND JUNCTION BOXES. PV 6.0
PV1V..,.,. , . ..
MICRO -INVERTER ATTACHED.
INVERTER COMPLIES WITH
RAPID SHUTDOWN REQUIREMENTS
AS OUTLINED IN CEC 690.12.
PV MODULE SPECIFICATIONS
MODULE MAKE AND MODEL
HYUNDAI HIS-S280RG(BK)
MAXIMUM POWER (DC)
280
WATTS
MAX POWER -POINT VOLTAGE (VMPP)
31.7
VOLTS
MAX POWER -POINT CURRENT (IMPP)
8.70
AMPS
OPEN CIRCUIT VOLTAGE (VOC)
38.5
VOLTS
SHORT CIRCUIT CURRENT (ISC)
9.4
AMPS
TEMPERATURE COEFFICIENT VOC
-0.42
%/°C
MAXIMUM SYSTEM VOLTAGE
1000V DC (UL)
THWN-2 OR NM (ROMEX) (EGC,GEC)
PV CIRCUIT 1: 9 MODULES/PARALLEL
PV CIRCUIT 2: 8 MODULES/PARALLEL
M
AC PHOTOVOLTAIC SYSTEM RATINGS
MAX AC OPERATING CURRENT
16.32
AMPS
MAX AC OPERATING VOLTAGE
240
VOLTS
*ROMEX WILL BE RAN THROUGH THE ATTIC WHERE
POSSIBLE
4.76 kW DC
3.91 kW AC
17 MODULES
MICRO -INVERTER SPECIFICATIONS
INVERTER MAKE AND MODEL
ENPHASE IQ6-60-2-US
RATED OUTPUT POWER (AC)
230
WATTS
NOMINAL OUTPUT VOLTAGE -(AC)
240
VOLTS
MAX OUTPUT CURRENT (AC)
0.96
AMPS
MAX INPUT VOLTAGE (DC)
48
VOLTS
MAX INPUT CURRENT (DC)
15
AMPS
MAX OCPD RATING (AC)
20
AMPS
MAX NUMBER OF PANELS PER CIRCUIT
16
THWN-2 OR NM (ROMEX) (EGC,GEC)
COMBINER PANEL VISIBLE LOCKABLE "KNIFE" A/C
ENVOY IQ 125A/240V DISCONNECT 30A/240V
(DRAWS 0.22 AMPS)
20A
BIGGS PRODUCTION
METER
20A M
20 A A / A
JUNCTION BOX
LOCATED ON ROOF
A B
GROUNDING WIRE
ADDITIONAL ROOFTOP DISCONNECT
NOT REQUIRED. ENPHASE MICROINVERTER
CABLE CONNECTORS MEET DISCONNECT
REQUIREMENTS. CEC 690.33
dol
U U-
EXISTING 240V/200A BUS -BAR RATED -
LOAD -CENTER (CENTER FED) PANEL.
BREAKER WILL BE FURTHEST POSITION
AWAY FROM DISCONNECT.
445 TRENT ST
BIGGS, CA 95917
200
RACEWAY AND CONDUCTOR SCHEDULE
TAG
CONDUCTOR TYPE
NIlNIMUM WIRE SIZE
# OF CONDUCTORS
RACEWAY / CABLE TYPE
MIND" CONDUIT SIZE
A
ENPHASE ENGAGE CABLE (USE -2)
12
2
USE -2 / FREE AIR
N/A
BARE COPPER (EGC/GEC)
6
1
BARE / FREE AIR
B
THWN-2 OR NM (ROMEX) *
10
4
EMT / ROMEX
3/4"
THWN-2 OR NM (ROMEX) (EGC,GEC)
8
1
C
THWN-2 OR NM (ROMEX) *
10
3
EMT / ROMEX
3/4"
THWN-2 OR NM (ROMEX) (EGC/GEC)
10
1
*ALL CONDUIT WILL BE
PAINTED TO MATCH
THE EXISTING
STRUCTURE.
AC DISCONNECT
LOCATED NEXT TO OR
WITHIN 10 FEET OF
MAIN SERVICE
PANEL (LINE OF SIGHT
MAINTAINED).
DESIGN WILL UTILIZE INTEGRATED
GROUNDING BETWEEN PV MODULES
AND RACKING
ENVOY -S METER POWERED BY
PV SYSTEM, PROTECTED BY
15A OCPD LOCATED IN 125A
COLLECTION PANEL
PERMANENT PLAQUES LABELED
"PV RAPID SHUTDOWN' WILL BE
INSTALLED ADJACENT TO THE
VISIBLE LOCKABLE A/C DISCONNECT
AND ON ARRAY JUNCTION BOXES
S � :fors
SHEET:
1 -LINE DIAGRAM
EL 1.0
1. THE ENPHASE IQ6-60-2-US
MICROINVERTERS MEET THE
REQUIREMENTS OF THE NATIONAL
ELECTRICAL CODE ARTICLE 690.35 FOR
UNGROUNDED PHOTOVOLTAIC POWER
SYSTEMS. NEC 690.35 ALLOWS FOR
PHOTOVOLTAIC POWER SYSTEMS TO BE
INSTALLED WITH UNGROUNDED
PHOTOVOLTAIC SOURCE AND OUTPUT
CIRCUITS. SYSTEMS THAT MEET THE
REQUIREMENTS OF NEC 690.35 ARE
EXEMPT FROM THE SYSTEM GROUNDING
REQUIREMENTS OF NEC 690.41.SYSTEM
GROUNDING.
2. NEC ARTICLE 690.43 EQUIPMENT
GROUNDING SPECIFIES THAT ALL
EXPOSED NON -CURRENT -CARRYING
METAL PARTS OF PV MODULE FRAMES, +
ELECTRICAL EQUIPMENT, AND
CONDUCTOR ENCLOSURES SHALL BE
PROVIDED WITH EQUIPMENT GROUNDING.
690.43(C) STRUCTURE AS EQUIPMENT
GROUNDING CONDUCTOR ALLOWS FOR
EQUIPMENT TO BE USED AS THE
EQUIPMENT GROUNDING CONDUCTOR IN
A PHOTOVOLTAIC SYSTEM. SPECIFICALLY,
"DEVICES LISTED AND IDENTIFIED FOR
GROUNDING THE METALLIC FRAMES OF
PV MODULES OR OTHER EQUIPMENT
SHALL BE PERMITTED TO BOND THE
EXPOSED METAL SURFACES OR OTHER
EQUIPMENT TO MOUNTING
SURFACES." THE DEVICES LISTED AND
IDENTIFIED FOR GROUNDIN&THE
EQUIPMENT MAY BE STAND-ALONE
GROUNDING COMPONENTS OR UL -2703
LISTED MOUNTING HARDWARE. IN AN
ENPHASE MICROINVERTER SYSTEM, IF
THE MICROINVERTERS AND MODULES
ARE BONDED TO THE RACKING
ASSEMBLIES WITH THE USE OF LISTED
AND APPROVED GROUNDING CLIPS OR
GROUNDING COMPONENTS, THE
EQUIPMENT GROUNDING CONDUCTOR
PROVIDED TO THE MICROINVERTERS
THROUGH THE ENPHASE ENGAGE CABLE
MAY ALSO BE USED TO GROUND THE
OTHER PHOTOVOLTAIC SYSTEM
COMPONENTS.
did IR.ONRID_GE XRRail,Farnilyi xR:Rau Famiiy;
e • TIi13.XR Rall FarnOyoffers the strertgtfl 01 a curried r211 to thjee targeted sizes%Each slze`supparts spt3oifia# -
_ n .Bre x ,
sSokFIs N6 AIways Sunny: -- - - _ _,_.. _- �h.:..1s -.
deslgnaoads while rttfnimliing material Costs. Depending on your Ilicatfo an R Rall io metiihi .
Overtheir UIij?,�solar panels etcpenence countless � t ;
extreme weather events Nol Just the worse storms'Irt ye@rs;
•,,but the worst stormsa`n 40 years High winds capable o; � _ • _ _ _ - ,�...:'- � - - - _ _ - - '
b ripping panels from a rcpt, andsnoM#lls:weighing
enough tp buckle's panel frame"
• ('XRRalls ara,;�he structural backbone preventing;
.-these results They resisluphft; protect 1 ti !4%A10)' - tXiii00, fxA1000
against buckling,and: safely and
y: ethctenll` -
.XiitD l�asleok,.lw,-Pronbma,rinrpc xRtoo,ldme ublmme maidemla! 't ,xRr000 rs•e rieowytrelgM dmons- - '
,transfer loads Into the bulldlrig: structure qr t r�14 a tea roi r�lons Y ui; lierdm 1 mo w� ra h 9,aPau n'ronR of, soar moumrla reps q d,ln to Iii ori
t Their superior spanning capability i rp crow h mmiews s root spa ts: w nne, wind end snow crond0kine krone obo W omB cgme[es and ePari iz ter ta.. '
,. s , rometring Ilght mtd,dmrfomlml.l mm�kr nd s! 'W RO cP to a tdot:• + moro for mxvnmdol o{�Ifcofloiis , , + ; j
� requires fewer root.attachments, t -- • -,,.y ,• • - .. _ _ -
- reducinglhenumberofrooi - � `� r f a p'>�+I�re�P�4+r.. , ,� soP?�±!+rreiry ';+r�+reIb - •
t penetrallons'rid the amount t _ ; Moderato load,eapaLlilb ifeaoq wad oapaLlWy"; r.� erdrome and ca�anlry - * `
t .. -.., . - Cloar 8 block anodlmd flntah i- t Cloei 8 bladt arodtzo0 nnffih I - ,:Clearand9xod nnUh -
�b1 Installation time � • r1 r ,JJ��1•�,,� .� �� � � • t I�r� stamov arailetiiu � mrmnitil:spnma wa➢adrle _' tnrenraf aPOees pvSnable - " -
� r � I � Rate -Selection. � " _ ••
„ 47tte following tattle was preparedin,cfimpilanoewfthspplicable ongineeiirtg odes.t nd standards Values are, .
based'on the followln` criteria ASCE.7.10 Roof Zone 1 .;Exposure 6, Ropi Sldof 711 27 ` tees and Meati=
Buil611i8 9 htNel 'ot 30 f£ Malt IronHfd s.00m for daCailed s
_ — i . a - �,• r 9 hon tables and`ceittfli:atians:: .
Force-Stsbffizfng Curve'
r,� s ; � Sloped roots gentfmW DdRl komcal edGlntdml ! i
r0lLES-are rratimmB rads vdtkft can cause umm y t'
• � t lo,borjd arui twra1.71io euxw! sliaRo of XR Roll's
1 'r•.. - s soe®Ily ddslm,ad to ftxT e.slm rfth h boli !
,, - dheplOnS Yldb rosletlng rho nYhdh+g TtdII'onlquo - - • !
. rtF- � - s tectum enSureS groater tmcufiy duAng etltmmW
i .s woodier and'e tdtfgw eYaOcn! uleUma _ , i
.Compat(bte.m;6,at &Pitched hoofs; Corrosfon`:Resistant Wteridls:; s
xR Rafts arp�,,, . ; tronRkrgo Olfq`m` AII,XR Rfiks ora madp o18000-^eri0s ;�e., ` i
Cotrtpabhtawitk r
4
ON ei �oerpaoroomoug rsruuraaormson, e L*plgvi 4""up{iltcaflons: 'e iriore ottrective eppeemrice; t
q
E ". �
1001
--
XR10 jF ltR_ 1110..; _ • f_tM_000
1401
I i
56
1m;
180;.
r
I160;