Loading...
HomeMy WebLinkAboutB18-0056 042-770-033BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspections is 3pm) Development Services cannot guarantee inspections on the date requested Office: 530.538.7601 Fax:530.538.7785 www.ButteCounty.net/dds Permit No: B18-0056 Issued: 1/8/2018 APN: 042-770-033 Address: 3280 SHELTERING OAK CT, CHICO Owner: POUNDSTONE CRAIG & DIANE LIVING Permit Type: GENERATOR RES Description: EMERGENCY BACK UP GENERATOR AREA Flood Zone: SRA Area: WTRACKS for Zoninyr- AG_ SRA. PW Front: Centerline of Road: Rear:, SRA: Street: AG: Interior Total Setback from Centerline of Road: ALL PLAN -REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING Inspection Tyve IVR INSP DATE Setbacks 131 Foundations / Footings 111 Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Signed Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 Blockin nde inin 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed Shearwall/B.W.P.-Interior 134 Shearwall/B.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 Manometer Test 605 Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Plumbing Final 813 Fire Sprinkler Test or Final 702 SwimminR Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencin AlarmsBaniers 1 503 Pre -Plaster 507 Manufactured Homes Setbacks 131 Blockin nde inin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Skirting/Steps/Landings 610 Coach Info Manufactures Name: Date of Manufacture: ' Model Name/Number: Serial Numbers: Length x Width: Insignia: .� Ts w � E s�-i: Yf..t . W'. '7s ,.' iti •� r x� �. 'ce Permit Final 802 Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test or Final 702 Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final **PROJECT FINAL *Project Final is a Certificate of Occupancy for (Residential nly) PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1.YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION Butte County Department of.Developinent Services PERMIT CENTER 7 County Center Drive, Oroville, CA 95965 �+++a• Main Phone (530) 538-7601 Fax (530) 538-7785 www.buttecounty.nef/dds Declaration of Installation for Smoke Alarms and Carbon Monoxide Alarms FORM NO DBI -01 The newly adopted 2013 California Residential Code requires the installation of Carbon Monoxide Detectors in dwelling units and in sleeping units within which fuel -burning appliances are installed and in dwelling units that have attached garages. The policy for Carbon Monoxide Alarms in Butte County states: "Any permit obtained in which the value of work exceeds $1000 associated with a Residential Group R Dwelling Unit or Sleeping Unit shall.conform to the following 2013 California Residential Code requirements for Smoke and Carbon Monoxide Alarms (Section R314 & R315)." 2013 California Residential Code requirements for Carbon Monoxide Alarms: R315.1 New construction: An approved carbon monoxide alarm shall be installed in dwelling units and in sleeping units within which fuel -burning appliances are installed and in dwelling units that have attached garages. R315.1.2 Power supply: For new construction required carbon monoxide alarms shall receive their primary power from the building wiring wheresuch wiring is served from a commercial source and. shall be equipped with a battery back-up. Alarm wiring shall be directly connected to the permanent building wiring without a disconnecting switch other than as required for over - current protection. Exceptions: 1. In dwelling units where there is no commercial power supply the carbon monoxide alarm may be solely battery operated. 2. In existing dwelling units a carbon monoxide alarm is permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. R315.1.3 Interconnection. Where more than one carbon monoxide alarm is required to be installed within the dwelling unit or within a sleeping unit the alarm shall be interconnected in a manner that activation of one alarm shall activate all of the alarms in the individual unit.' Exception: 1. Interconnection is not required in existing dwelling units where repairs do not result in the removal of wall and ceiling finishes, there is no access by means of attic basement or crawl space, and no previous method for interconnection existed. _ " R315.2 Where required in existing dwellings:, Where a permit is required for alterations, repairs or additions exceeding one thousand dollars ($1,000); existing dwellings or sleeping units that have attached garages or fuel -burning appliances shall be provided with a carbon monoxide alarm in accordance with Section..R315.1. Carbon monoxide alarms shall only be required in the specific dwelling unit or sleeping unit for which the permit was obtained. R315.2.6 Alarm requirements: No person shall install, market, distribute, offer for sale or sell any carbon monoxide device in the State of California unless the device and instructions have been approved and listed by the State Fire Marshal. Pagel of 2 Revised 7.20.2015 , Carbon monoxide alarms required by Sections R315.1 and R315.2 shall be installed in the following locations: 1. Outside of each separate. dwelling unit sleeping area in the immediate vicinity of the bedroom(s). 2. On every level of a dwelling unit including basements. R315.1.5 Multiple -purpose alarms: Carbon monoxide alarms combined with smoke alarms shall comply with Section R315, all applicable standards, and requirements for listing and approval by the Office of the State Fire Marshal, for smoke alarms. Butte County's Interpretation of;2013 CRC, Sections 314 & 315 for Smoke Alarms & Carbon`Monoxide Alarms: ,Where alterations, repairs or additions exceeding $1,000 in valuation, existing dwellings shall be retrofitted with smoke alarms and those that have attached garages or fuel -burning appliances shall have carbon monoxide alarms installed. Existing smoke alarms can be replaced with dual function alarms for Smoke and Carbon Monoxide and in most cases will,comply with the aforementioned code requirements for Carbon Monoxide Alarms. DECLARATION OF INSTALLATION UNDER THE PENALTY OF PERJURY As Owner/Contractor, I/we affirm and declare under the penalty of perjury, under the laws of the State of California, by our signatures below as Owner/Contractor, that I/we will comply prior to final inspection with Items A $ B as specified herein: A. Both Owner/Contractor have read and clearly understand the aforementioned 2010 California Residential`Code (CRC) Carbon Monoxide Alarm requirements. B. Both Owner/Contractor are responsible for installing Carbon Monoxide Alarms prior to final inspection as per the aforementioned building code and maintaining such installation. Smoke Alarms will also be installed prior to final inspection as per the 2010 CRC. invoke and Arbon Monoxide alarms are row installed in the fQ_Ilowing,(gons: -- �rys•a�r5����p,eQ,M,; �5 //J W*t_A-Y s Owner's name (print): �.�/�! r&A&1s�4a14_1_ Owner's signature: /,/Date: Contractor's name (print): V'N W1' CSLB License: Contractor's signatur Date: O L- 29 1 �G Project Address: 5Zgb sl i�'?�!�/-�— 1 Permit #: R/[� Page 2 of 2 Revised 7.20.2015 cb tel. 0 I 11 ,i { �' t :(�. u � � l� pebl - `' � L r ✓ T �� ���yyy� •;� b - ��l% �f �',� � .� �. rj 'h4'_�t'.- - b �•ipo4 '� {1 ti `Y"° o _- E�"n `4 o't°` �, - ,s\ 1� �/ - JI4` 11-0 1 Kit I VON �(. VVI two QW, tI r i 16/20/22 kW INCLUDES: • True Power'" Electrical Technology • Two Line LCD Multilingual Digital Evolution'" Controller (English/Spanish/ French/Portuguese) • Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 4 for Details. • Electronic Governor • System Status & Maintenance Interval LED Indicators • Sound Attenuated Enclosure • Flexible Fuel Line Connector GENERAC° GUARDIAN® SERIES Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating Models G007036-0, G007037-0 (Aluminum - Bisque) - 16 kW 60 Hz Model G007035-0 (Aluminum - Bisque) - 16 kW 60 Hz Models G007039-0, G00703&0 (Aluminum - Bisque) - 20 kW 60 Hz Models G007043-0, G007042-0 (Aluminum - Bisque) - 22 kW 60 Hz • Direct -To -Dirt Composite Mounting Pad • Natural Gas or LP Gas Operation C&USQv' T • 5 Year Limited WarrantyLISTED Note: CUL certification only applies to unbundled units and units packaged with ored nly.switches. Units packaged with the Smart Switch are UL certified in the • Capability to be installed within 18" (457 mm) USA of a building* 'Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes. FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's O success in providing the most reliable generators possible. Generac's G -Force engine lineup offers added peace of mind and reliability for when you need it the most. The G -Farce series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. O . TRUE POWER— ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at :t1%. SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are J PROTOTYPE TESTED J NEMA MG1-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this V SYSTEM TORSIONAL TESTED V MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. w GENERAC a17'3 @PR0MISE • •ti��oyeP `fieLick • Bullr rn rfu USa uslnp Oomefrlc aM lmelpn palll. Generator • Revolving field .Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. . • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to ±1 % prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers your vital electrical loads to the energized source of power. • NEMA 313 Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near your existing distribution panel for simple, low-cost installation. Evolution- Controls • GENERAL® 16/20/22 kW features and benefits Engine ' • Generac G -Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine Smooth, weather -resistant user interface for programming and operations. run cooler, reducing oil consumption resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featur- ' ing up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field .Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. . • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to ±1 % prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers your vital electrical loads to the energized source of power. • NEMA 313 Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near your existing distribution panel for simple, low-cost installation. Evolution- Controls • Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltEge, setpoints 65% dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the -factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. - • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature: Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Litt -out front for easy access to all routine maintenance items. Electrostat- ically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade.muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" away from a building. Installation System , • 1 tt (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. • • Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. • Integral sediment trap i Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. Dimensions (L x W x H) in/mm _ - 48 x 25 x 29/1218 z 638 x 732 r Sound output in cIB(A) at 23 ft (7 m) with generator operating at normal load** 66. - _ 66 67 [Sound output in dB(A) at 23 ft (7 m) with generator in Quiet -Test'° low -speed exercise mode"' 58 _ _• • 58 s 58 .: 1 : - GENERAC': S min 5 min ' Engine Type of Engine GENERAL G -Force 1000 Series GENERAC G -force 1000 Series GENERAC G Force 1000 Series Number of Cylinders , , - 2 16/20/22 kW - . ;',:: specifications 999 cc {, 999 CC 999 cc •- Cylinder Block 140-(3.87) Aluminum w/ Cast Iron Sleeve at all load ranges - 3.5-7" water column (7-13 mm Generator • Overhead Valve Overhead Valve Overhead Valve ti Madels ` 6007035.0, 0007036.0, . ' G007038.0, G007039-0 G007042-0, G007043-0 Solid-state w/ Magneto , Governor System , - t t t"• G007037-0 (16 kW) » (20 kW) (22 kW) ; Compression Ratio 9.5:1 ` Rated Maximum Continuous Power Capacity (LP) _ _ 16,000 Watts%- 20;000 Watts' ' -2 12 Vdc _ 12 Vdc Rated Maximum Continuous Power Capacity (NG) 16,000 Watts' ' 18,000 Watts' 19,500 Approx. 1.9 gV1.8 L Approx. 1.9 gV1.8 L a Rated Voltage 240 240 240 3,600 ; •- Rated Maximum Continuous Load Current — 240 Volts (LP/NG) t - 66.6/66.6 - 83.3/75 91.6/81.3, Total Harmonic Distortion Less than 5% Less than 5% ,,Less than 5% Main Line Circuit Breaker° • 70 Amp , r , 100 Amp 100 Amp Phase ,.. 1 I 1 1 , Number of Rotor Poles` 2 t - 2 ' < 2 , Rated AC Frequency 60 Hz 60 Ht : r 60Hz Power Factor ��,.! ' • ; 1.0 s •' ;1.0 - 1.0 Battery Requirement (not included) 12 Volts, Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum Unit Weight (Ib/kg) - r r -� 406/186 448/203 -466/211 - Dimensions (L x W x H) in/mm _ - 48 x 25 x 29/1218 z 638 x 732 r Sound output in cIB(A) at 23 ft (7 m) with generator operating at normal load** 66. - _ 66 67 [Sound output in dB(A) at 23 ft (7 m) with generator in Quiet -Test'° low -speed exercise mode"' 58 _ _• • 58 s 58 Exercise duration 5 min S min 5 min ' Engine Type of Engine GENERAL G -Force 1000 Series GENERAC G -force 1000 Series GENERAC G Force 1000 Series Number of Cylinders , , - 2 2 2 • Displacement 999 cc {, 999 CC 999 cc •- Cylinder Block 140-(3.87) Aluminum w/ Cast Iron Sleeve at all load ranges - 3.5-7" water column (7-13 mm ' Valve Arrangement Overhead Valve Overhead Valve Overhead Valve ti Ignition System Solid-state w/ Magneto Solid-state W/ Magneto Solid-state w/ Magneto , Governor System , - t , r Electronic Electronic • • 'Electronic Compression Ratio 9.5:1 9.5:1 9.5:1 Starter � - I. 12 Vdc _ 12 Vdc Field Upgradable Firmware Oil Capacity Including Filter Approx. 1.9g111.81 Approx. 1.9 gV1.8 L Approx. 1.9 gV1.8 L a Operating rpm ' 3,600 3,600 3,600 ; Fuel Consumption . , .. I ' ' r • „ r Natural Gas , Its/hr (m3/hr) - Mode Buttons -.Auto Automatic Start on Utility failure. 7 dquerciser. Manual 1/2 Load - , s, 218 (6.17) 204 (5.78) 216 (6.12) Full Load' - 309 (8.75) • 301 (8.78) 310 (8.78): - Liquid Propane If% (gal/hr) (1/hr)' Utility Voltage Loss/Return to Utility Ad]ustable (Brownout Setting) From 140-171 V/190-216 V. I •� • • 1/2 Load 91.6 (2.52) [9.53] 86(2.3 7) (8.99] 93.2 (2.56) [9.70] Full Load A06.8 (2.94) [l 1. 11 ]__L 29.6 (3,56) [13.48] 140-(3.87) Note: Fuel pipe must be sized for full load. Required fuel -Pressure to generator fuel inlet at all load ranges - 3.5-7" water column (7-13 mm mercury) for natural gas,10-12' water column (19-22 mm mercury) ror Lr gas. For Btu content, multiply B"/nr x 1SUU (LN) or RI/hr x 1 UUU (NG). For Megaloule content, multiply mJ/hr x 93.15 (LP) or mJ/hr x 37.26 (NG) Controls ,.: ' ' r • „ 2 -Line Plain Text Multilingual LCD Display y - Simple user interlace for ease of operation. Mode Buttons -.Auto Automatic Start on Utility failure. 7 dquerciser. Manual Start with starter control, unit stays on. If utility fails, transfer to load takes place. ' : •• IN Stops unit. Power is removed. Control and charger still operate. + • _ Ready to Run/Maintenance Messages + -• Standard Engine Run Hours Indication Standard Programmable start delay between 2-1500 seconds , Standard (programmable by dealer only) Utility Voltage Loss/Return to Utility Ad]ustable (Brownout Setting) From 140-171 V/190-216 V. Future Set Capable Exerciser/Exercise Set Error Warning �' r - , Standard - ' RurVAlarm/Maintenance Logs 50 -Events Each Engine Start Sequence _ „ Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration). + Starter Lock -out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger , . Standard Charger FaulVMissing AC Warning • - -7 Standard «•. , Low Battery/Battery Problem Protection and Battery Condition Indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard , Under-Frequency/Overload/Stepper Overcurrent Protection + t Standard Safety Fused/Fuse Problem Protection Standard ' Automatic Low oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown r Standard High Engine Temperature Shutdown Standard Internal Fault/Incorrect Wiring Protection Standard - Common External Fault Capability r •c. '; ___ .., ' .; ,. Standard Field Upgradable Firmware _ , _ Standard "Sound levels are taken from rhe front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. Rating definitions -Standby: Applicable for supplying emergency power for the duration r of the utility power outage. No overload capability, is available for this rating. (All ratings in accordance with BS5514, IS03046 and DIN6271). • Maximum kilovolt amps and current are subject to and limited by such factors as fuel Blutmegaloule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feel (304.8 meters) above sea level; and also will decrease about 1 percent for each 6 °C (10 T) above 16 °C (601). r. t Note: The 50 amp switch is flush mountable. H1 and W1 refer to mounting hole spacing - H2 and W2 are cover dimensions. H3 and W3 are the enclosure dimensions without cover., ` DEPTH ! wz Wire Ranges Conductor Lug Neutral Lug. s Ground Lug 1/0-#14 2/0-#14. ' 2/07#14,•+. -, GENERACO 16/20/22 kW :: Y 'o.,switch�options Limited Circuits Switch_ Features_ Model } G007036-0 (16kW) • 16 circuits, breakers not included. No. of Poles 2 100 Current Rating (Amps) • Electrically operated, mechanically -held contacts for fast, positive,.. ; _ ° • connections �. ° Voltage Rating (VAC) - r 't 120/240,-,10 ' 6_ . • Rated for all classes of load, •100% equipment rated, both inductive and Utility Voltage Monitor (Fixed)' -Pick-up c w ' 80% j. resistive. Dropout r 65% ' • 2 pole, 250 VAC Contactors. Return to Utility' approx. 15 sec ` • 30 millisecond transfer time. Exerciser bi-weekly for 5 minutest Standard + . "• Dual coil design.: - �. IN Listed Standard- • ' Rated for both copper and aluminum conductors. ._' `� " .� Notal Circuits Available 16 • Main contacts are silver plated or silver alloy to resist welding and sticking. Tandem Breaker capabilities 8 spaces •. NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor Circuit Breaker Protected' .. Available RMS Symmetrical mounting flexibility. - Fault Current @250 Volts 10,000 • .Multi listed for use with 1" standard, tandem, GFCI and AFCI breakers from *Function of Evolution Controller Siemens, Murray, Eaton and Square D for the most flexible and cost effec-.'.+ Exercise can be set to weekly or monthly, • ' tive install. Dimensions k .., w,= Note: The 50 amp switch is flush mountable. H1 and W1 refer to mounting hole spacing - H2 and W2 are cover dimensions. H3 and W3 are the enclosure dimensions without cover., ` DEPTH ! wz Wire Ranges Conductor Lug Neutral Lug. s Ground Lug 1/0-#14 2/0-#14. ' 2/07#14,•+. -, 1 • Service Rated Smart Switch FeaturesModel - G007037.0 (16 kW)/GO07039.0 (20 kW)%r.., • Includes Digital Power Management Technology standard (DPM). ' G007043-0 (22 kW) - •No. of Poles 2 r Intelligently manages up to four air conditioner loads with no additional - Current Bating (amps) 200 hardware. Voltage Rating (VAC) 120/240.10 • . Up to four more large (240 VAC) loads can be. managed when used in = Utility Voltage Monitor (Fixed) - + , conjunction with Smart Management Modules (SMMs). -Pick-up 80%'. _ • Electrically operated, mechanically -held contacts for fast, cle-Dropout 65%an connections. Return to utility' - - approx. l3sec • Rated for all classes of load, 100% equipment rated, both inductive and resis- tive. Exerciser weekly rot 5 minutes' Standard . ULListed+Standard • Up to four more large (120/240 VAC) loads can be managed when used in con- Enclosure Type, . _ NEMANL 3R ' z junction with 50 amp Power Management Modules (PMM* *). Circuit Breaker Protected22,000 • 2 pole, 250 VAC contactors. r r Lug Range 250 MCM - #6 � • ' Service equipment rated, dual coil design. *Function of Evolution Controller'+ • Rated for both aluminum and copper conductors. • = Main contacts are silver plated or silver alloy to resist welding and sticking. - w, ' 4 • - NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mount-- ing flexibility. Dimensions ,� k +• L Model# Product Description •; { ` G007035-0. Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac - G006463 -4 Mobile Link`" cess to an lntemet connection from a PC or with any smart device: You will even be notified via e-mail'or 696471070378 G007038-0 text message when a change in the generator's status occurs. Available in the U.S. only. G007039-0 696471070392 Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet G005819-0 26R Wet Cell Battery cell battery for use with all air-cooled standby product (excluding PowerPact®)., G007101-0 Battery Pad Warmer The pad warmer rests under the battery. Recommended for use if the temperature regularly falls below 0°F.. (Not necessary for use with AGM -style batteries). G007102 0 Oil Warmer Oil warmer slips directly over the -oil fitter. Recommended for use if the temperature regularly falls below 0°F. G007103-0 Breather Warm" The breather warmer is for use in extreme cold weather applications. For use with Evolution controllers only in climates where heavy icing occurs., Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load G005621-0 ' Contact Kit you may not need. Not compatible with 50 amp p're-wired; switches.' . s ;` Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a G007027-0 Bisque (Standard on 22 kW) sleek, contoured appearance as well as offering protection from rodentsand insects by covering the lifting holes located in the base. ' If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from G005703-0 - Bisque Paint Kit future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G006485=0. . ' Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic' standby generator.. G006873-0 Smart Management Module' Smart Management Modules are used in'conjunction with the Automatic Transfer Switch to increase'its' (50 Amps) power management capabilities. It provides additional power management flexibility not found in any other power management system.,* dimensions t PCs - Dimensions shown are approximate. Refer to installation manual for eiact dimensions. 00 NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. - .. 1218— —I 8 r8., .1 "a—, a- 14&0lnl I t r LEFT SIDE VIEW r GENERAC® Model UPC G007035-0. 696471070354 ' G007036-0 696471070361 ' G007037-0 696471070378 G007038-0 696471070385 G007039-0 696471070392 G007042-0 696471070422 G007043-0 696471070439 •4 FRONT VIEW _, - • . 1 Generac Power Systems, Inc. •S45 W29290 HWY. 59; Waukesha, WI 53189 • generac.com 4 02016 Generac Power Systems. Inc All rights reserved. All speciit60ons are subject to change without nbdce. Part No. 10000000194-010/03/16 .Autoifiatic ..Transfer- Switches 2j, GENERAC . Autom Service and non -Service iated.. - hes ransfer WfiC. -Single Phase .100, -''400-Amps,s. C Ili LISTED CUL only applies to non -service rated switches Description denerac Automatic Transfer Switches -are designed for rise with _single p1hase g6nerators that utilize an Evolution TM or Nexus'"" Controller. The 100, 200, and 400 amp open transition switches are available'in single phase in both'service equipment rated and non -service equipment rated configurations. The 150 and 300 amp open transition switches are only available in a service rated equipment configuration. Standard Features, • Service rated (RTSW)Gerierac Automatic Transfer. Switches'are housed in an aluminum NEMA/UL Type 3R enclosure*, with electrostatically,applied and baked powder paint. The Heavy Duty Generac Contactor is a UL're'cognized device, designed for years of service. The controller it the g6erator handles all, the timing, sensing, exercising functions, and transfer commands. All switches are covered by a 5 year limited warranty. Non -service rated (RTSC) switches are Kous6d in a steel enclosure. DPM Technology Through the use of digital power technology (DPM), ihdse 'switches have the capability to manage up to 4 individual HVAC (24 VAC_ control led)'foads with no additional hardware. When used in tandem with Smart Management Modules, up to 8.more loads can be., managed as Well, providing the most installation efficient power management options available. G Wa ENER. Model RTSC10OA3 RTSW10OA3 RTSW150A3 RTSC20OA3 1 RTSW20OA3 RTSW300A3 RTSC40OA3, RTSW400A3 GENERAC® 100 100 150 200 • 10®:4®® Amps,Single Phase `3 • ' * Automatic' Smart Transfer Switches . 400 400 �. Voltage Functions 120/240,1 a • All.timing and sensing functions originate in tlie'generator controller 120/240, to Utilityvoltage drop-out ..................... . ..........`............................................'...............'.....:.....:...............................................................::.......<60% 120/240; 1 e - Timer to generator start ................. :.._......................:.......'.'.................`............:..............10 _ second factory set, adjustable between 2-1500 secbnds by a qualified dealer` Load Transition Type - , (Automatic) Enginewarm up delay..................................................................:...............................:..............:......':.`......:...:......................................................................5 seconds ' Open Transition Service Rated Standby voltage sensor....................................... '............................... ....................................... ................................................................................... 60%for 5 seconds , Open Transition Service Rated,. Utility voltage pickup .................... :......................... .......................................................... '....:.:...................................... ...................... .............. ........... ..:....:_.............>80% Enclosure Type Re -transfer time delay.....................:................."....:...........:...........:....................! .....:..................:...:....:...................... ....:..... ...........................................15 seconds r Engine coal -down timer..........................:....................:...............:...................................................' ......".'.:..........`.................:........:.:.:....... .............:....60 seconds Exerciser•.............:...:..'.........................:...'......................................................................'..............................................................................12 minutes every 7 days - The transfer switch can be operated manually without power applied.. • ' 'When used in conjunction with units utilizing Evolution" controls UUCUL UL UL Specifications UL UL UL/CUL,: Model RTSC10OA3 RTSW10OA3 RTSW150A3 RTSC20OA3 1 RTSW20OA3 RTSW300A3 RTSC40OA3, RTSW400A3 Amps i 100 100 150 200 200 300. 400 400 �. Voltage 120/240, .1 a 120/240,1 a 120/240, to 120/240, to 120/240-1 o 120/240; 1 e 120/240,1 O 120/240,1 e Load Transition Type - , (Automatic) Open Transition _Open Transition Service Rated Open Transition Service Rated Open Transition Open Transition Service Rated „ Open Transition Service Rated,. Open Transition ?f Open Transition Service Rated - Enclosure Type NEMA/UL 3R NEMA/UL 313 NEMA/UL 3R NEMA/UL'3R NEMANL 3R NEMA/UL 313' NEMA/UL 3R NEMA/UL 3R. UL Rating' UUCUL UL UL UL/CUL- UL UL UL/CUL,: UL' . Withstand Rating (Amps) 10,000 10,000' 22,000' 10,000 22,000 22,000 22,000 22,000 r Lugf Range ` 1/0 - #14 250 MCM - #6 600 MCM - #4 or 1/0 - 250 MCM Dimensions ' , _ • , «'C i k w. C, ` H2 .♦ MI y J Model ' RTSC10OA3 RTSW10OA3 RTSW150A3 RTSC200A3 RTSW20OA3 RTSW30OA3 RTSC40OA3 RTSW40OA3 Ht 17.24/437.9 17.24/437.9 26.75/679.4 17.24/437.9 26.75/679.4 42.91/1089.9 31.25/793.8 42.91/1089.9 Height r (inlmm) a20/508 H2 20/508 30/762 20/508 30/762 48/1219.2 36/914.4 48/1219.2 Wt 12.5/317.5 12.5/317.5 10.5/266.7 12.5/311.5 10.5/266.7 16.69/423.9 19.18/487.2 16.69/423.9 .Width ' (inJrnm) W2 14.6/370.8 14.6/370.8 13.5/342.9 14.6/370.8 13.5/342.9 21.82/554.2 24/609.6 21.82/554.2 Depth (inJmm) 7.09/180.1 7.09/180.1 6.3/160.1 7.09/180.1 6.3/160.1 10.06/255.5 10.06/255.5 10.06/255.5 ,Weight (lbsAilos) 20/9.07 22.5/10.21 39/17.69 20/9.07 39/17.69 140/63.5 133/60.33 140/63.5 DEJP J I_ W27 + •. " WI • H2 - 7,'' H1 - • . . DEPTH 1— W2, --I • _ GENERAC• Generac Power Systems, Inc. • S45 W29290rHWY. 59, Waukesha, WI 53189 • generac.com 02015 Generac Power Systems, Inc. All rights reserved. An specifications are subject to change vnlhout notice. Bugetin OL3205•B Printed In U.S.A. 07/28/15 ' DATE: ESTIMATE # PROPOSAL SUBMITTED TO:December 21, 2017 REVISED - NAME: JOB NAME: Diane Poundstone - Residence STREET: - STREET: 3280 Sheltering Oak Court Same CITY:. ' ' CITY:,. STATEN ,Chico .' Same CA REASON: PHONE: EMAIL Generator Installation 530-228-0226 dpound3333@gmail.com We hereby submit proposal for installation of Customer, supplied 22kw generator on composite pad provided with generator. Connect customer provided transfer switch to existing main electrical panel and connect all -loads to new transfer switch. Install new`gas line from "T" in gas line to'generator with new trench and backfill as needed. Prepare ground and install new gravel base as recommended by generator company. Startup acid testing of generator when complete. Install proper signage as needed: Exclude: off -shift or overtime labor, propane tank,•concrete pad or soil tests, main panel upgrade or repairs. Note: Proposal includes connection to natural gas meter.for new generator. Gonsistently Exceeding Gustomer Expectations We hereby. propose to furnish labor and materials -complete in accordance with the above specifications, for the sum of with payments to be made as follows: FULL PAYMENT DUE UPON COMPLETION. All material is'guai anteed to be as specified. All work to be completed in a workmanlike manner according to standard practices. Any alteration or deviation from above specifications involving extra costs will be executed only upon written orders, and will become an extra charge over and above the estimate. All agreements contingent upon strikes, accident or delays beyond our control. This proposal subject to acceptance within 30 days and it is void thereafter at the option of the undersigned. r ' -Skip Whaley t' Skip Whaley - QUICK SERVICE DEPT. - Office 891-1933 ext 219 -Fax # 897-6183 Cell # 518-4029 ACCEPTANCE OF PROPOSAL ♦' - The above prices, specifications and'conditions are hereby accepted. You are authorized to do the work as specified. Payment will be made as outlined above. ACCEPTED: t ♦ . • Signature DATE Signature - { chicoelectric.com = 36 W. Eaton Road ,e . Chico, CA 95973-0149 'e' 530-891-1933 e Fax 530-897-6183 CA License #454345 Y Generator Installation Chico Electric Poundstone, Diane _ 36 West Eaton Road 3280 Sheltering Oak Court Chico, Ca. 95973 Chico, Ca: ' 530-518-4029 Contact: Skip Whaley Permit # New natural gas generator installation 22kw. ,Existing 200 amp meter panel with 1- 200 amp 2 ` pole main breaker (Nem,) 200 Amp automatic 200 Amp transfer switch (New) 22kw Residential generator in back Meter yard area. Main Panel t (New) chase nipple to 200 amp transfer switch with 2" conduit and #2 (New) 1.5" copper wire. conduit with 3 - #2 Cu and one #6 copper wire . t Butte County Department of Development Services PERMIT CENTER 7 County Center Drive, Oroville, CA .95965 Main Phone 530.538.7601 Fax 530.538.7785 %v\\•\•v. buttecounfv. nel/d(is SITE PLAN Assessor's Parcel Number: ❑ ❑ ❑ D ❑ ❑ ❑ ❑ ❑ Permit #: ra FORM NO DBP -3 Owner Name: >sar.T£ Scope 6f Work: BUD 64) C&A S1V rY\e 2 5(,LPPG K -VQ Site Location: 3ZIBO fVN044l Contact name:._SK'w VuRnita—y Phone: 6-36- Sig— OZ Flood Zone: Scale 1"_ 02A 4 - � OEVELO;MEN1 5EEVGES Revised! 7.2/0. 2 D 'J_t) Pace I of I 1. ELECTRICAL.,'MECHANICAL, AND PLUMBING'- CONSTRUCTION-.:,( NOT! PLAN CHECKED .) SHALL COMPLY WITH CURRENT •EDITION OF NEC, • UMC AND UPC. NOWE: All Materials & Worinnanship Shall Be In Accordance with Recognized Good Practioes and of a Quality Prescribed for the Specified use in the Uniform BuIldin.g, Plumbing & Mechanics: Codes and the National Electr�cel Code ?hie not of plane —d upecaucam= YET be kept on the job at all times and it Is unlawful to e any changes or alterations on same withoact ermission from the Department of Public y4orka. Co of Butte. / /* i C `SLS ; . p+x K !—• •-- - ----- •-- -'\ \� -• � \ � = .f.SEh'�' ---........... � ; ,•. � . RM off:_.. �_• s�� \ . ��,r�T I c �i �c Stio►ti N Sl-:', ALL STRUCTURES AND EQUIPMENT IN X. rV7-�- OVERHANGS SHALL BE CLEAR OF ALL EASEMENM A SET BACK OF FT. FROM THE SIDE AND ; FT. FROM THE' REAR PROPERTY LINES AND I I E41 Ff. FROM THE ROAD CENTERLINE SHALL BE I ----_CLEAR OF STRUCTURES AND EQUIPMENT EXCEPT T I Y R A a FT. EAVE ovER LFx'CALL rl. HANG. \ \` ti ENG" = �S II / �Rac ;ION OP�1 oo TSG BUTTE COUNTY BUILDING DEPARTMENT. ING . • ��� �� ` ; l 'SGP�i.,�(i� .:-301 PILE COPY.... . _ SHELTERING OAK N'. to -Plan i lN� to- L)c►5TiN� SII do P, C4 iBLCI 3000 CoNcW-Ftr R eoJL gals*1Ny kr. 3�N P,LNjo F,c�:1� �iFoorK fi„os�a� K LG SOS ,v fi I EEL Poo r �v 02�t+���( Fx �bt�iy '�j stunt_' Sfir_ F 2 rY ' ✓ �,1. � Win- ,•l 6b 1-7 5kc .wiNG DIVISION - BUILDING PLAN APPROVAL Use: - .Date:_47/0( pl # • C� Partin . Landscaping: �►�`� Other. Sri Signature: H w\T '�; 0ql-77p_033-00' C6�iA-cC� C'ovw�stnrvC . , _ \ 3 270 -6 E��-i'2intCr C (14 q G—g73 ��a-8aoz •