Loading...
HomeMy WebLinkAboutB18-0187 030-140-026BUTTE COE*TY AREA DEPARTMENT OF DEVELOPMENT SERVICES 1 INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) :5A,538.4365 (Cut off time for inspections is 3pm) Development Services cannot guarantee inspections on the date requested Office: 530.538.7601 Fax: 530 Permit No: B18-0187 Issued: 1/25/2018 APN: 030-140-026 Address: 1345 12TH ST, OROVILLE Owner: REDBURN BRADLEY Permit Type: SOLAR ROOF -RES Description: New grid -tied solar roof mount using microinv 3sa. i /63 www.butieuounty.neyaas Flood Zone: X (Unsh - SRA Area: Front: Centerline of Road: Rear: SRA: Street: AG: Interior Total Setback from Centerline of Road: LRA ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING Inspection Type IVR INSP DATE Setbacks 131 Foundations / Footings IN l Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Sign d Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing r 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing --412 Under Slab Plumbing 411 Blockin /Under inin 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed Shearwall/B. W.P.-Interior 134 Shearwall/B.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 Manometer Test 605 Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 31.6 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Plumbing Final 813 Fire Sprinkler Test or Final 702 Swimming Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 503 Pre -Plaster 507 Manufactured Homes Setbacks 131 Blockin /Under inin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Skirtin /Ste s/Landin s +—LL— CoachInfo Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: Length x Width: Insignia: w'..:.,mb,.`�.,.+'-i,v.'a..'.:i-�issiF't.'��+z".F'_. :1 Public Works Final 538.7681 Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test or Final 702 'PROJECT FINAL 3 tX Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final 'PROJECT FINAL 3 tX -t-ro)ect rinai is a t -truncate of occupancy for (tcesiaenttai linty) PERMITS BECOME NULL AND VOID 1 YEAR FROM ]'HE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU NIAY NAY FOR A 1 YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION i Sunmodule;/ PI u S- SW SW 285 MONO �. 1 _ ;' TUv Power controlled: ' Tovaheinlane € Lowest measuring tolerance in industry ��. + 6,3,E • ` ' • 000002 . , • Every component is tested to meet 3 times IEC requirements r Designed to withstand heavy accumulations of snow and ice OSunmodule Plus: Positive performance tolerance V. 25 -year linear performance warranty and 10 -year product warranty Glass with anti -reflective coating . t - World-class quality Fully -automated lines WeROed.IEC 6,:,s • A • oefCy totted. IEC 61730 :Ammonb rceN uxe € production and seamless monitoring of the process andlmate . Pedodlc InepeaiRn rial ensure the quality that the company sets as its benchmark for its sites w�Idw�ide. ° eeeeeri° , SolarWorld Plus -Sorting Mlsr Plus-Sorting guarantees highest system efficiency. SolarWorld only delivers m' Ddeles. s+r RESIS7Ml �NQ t7 PRdU� C us that have greater than or equal to the nameplate rated power. UL 1703 • 25 -year linear performance guarantee and extension of product warranty to 10 years SolarWorld guarantees a maximum performance digression of 0.7% p.a. in the =o: rse: VE E llflr of 25 years, a significant added value compared to the two-phase warranties com- 'mon in the industry. In addition, SolarWorld is offering a product warranty, vJh rh has R L� . been extended to 10 years.' F.amelnnwa..ion ' 'in accordance with the applicable solarworld Limited Warranty at purchase. NuEG GREEN QRT fIEO. f www.solarworld.com/warranty solarworld.com:- : MAXIN USA OF Us ANC IMPORTED PARTS . t - a Sunmodule%Plus ,,,SW 285 MONO PERFORMANCE UNDER STANDARD TEST CONDITIONS (STC)' Maximum power Pm„ 285 Wp Open circuit voltage Vp 39.7 V Maximum power point voltage Vmpp 31.3 V Short circuit current 1„ 9.84 A Maximum power point current Impp 9.20 A Module efficiency n, 17.0% 'STC: 1000 W/m2, 25'C, AM 1.5 1) Measuring tolerance (P,)traceabletoTUVRheinland:+/-2%(TUVPowerControlled) THERMAL CHARACTERISTICS NOCT 46'C TC 1,, 0.04 %/'C TC vx -0.30 %/'C TC Pmpp -0.41 %/'C Operating temperature -40'C to 85'C Module voltage IV] V« 65.94 1.22 (31) 1.33 (288) Version 2.5 frame bottom mounting holes i_ x4 4.20 (107)t PERFORMANCE AT 800 W/M', NOCT, AM 1.5 Maximum power Pm„r 213.1 Wp Open circuit voltage V. - 36.4 V Maximum power point voltage Vmpp 28.7 V Short circuit current 1„ 7.96 A Maximum power point current Impp 7.43 A Minor reduction in efficiency under partial load conditions at 25'C: at 200 W/m2,100% (+/-2%) ofthe STC efficiency (1000 W/m2) is achieved. COMPONENT MATERIALS Cells per module 60 Cell type Mono crystalline Cell dimensions 6.17 in x 6.17 in (156.75 x 156.75 mm) Front Tempered glass (EN 12150) Frame Clear anodized aluminum Weight 39.51bs (17.9 kg) SYSTEM INTEGRATION PARAMETERS r Maximum system voltage SC Il / NEC 1000 V Maximum reverse current 25A Number of bypass diodes 3 Design Loads Two rail system 113 psf downward 64 psf upward Design Loads' Three rail system 170 psf downward71 psf upward Design Loads' Edge mounting 30 psf downward 30 psf upward 'Please refer to the Sunmodule installation instructions for the details associated with these load cases. ADDITIONAL DATA Powersorting' -0 Wp/+5 Wp 1 -Box IP65 Module leads PV wire per UL4703 with H4 connectors Module type (UL 1703) 1 Glass Low iron tempered with ARC VERSION 2.5 FRAME Compatible with both "Top -Down" and "Bottom" mounting methods ♦Grounding Locations: - 4 corners of the frame - 4 locations along the length of the module in the extended flangef All units provided are imperial. SI units provided in parentheses. SolarWorld AG reserves the right to make specification changes without notice. SW-01-6007US 12-2014 Chilicon Bower Microinverters t� • • a t n r CHILICON POWER CP. -250E 4 7 ! Maximum Energy Production •. Reliability by Design Enhanced Monitoring ' Simplified Installation 1 : - ` Safety I • NVV-I�Ni. CI:IIIICOrI hOWCr " To learn more about Chilicon Power Microinve ters,' visit chiliconpower.com r R:v CP-250E-60-72-208/240-MC4 Microinverter Specifications INPUT DATA (DC) R.ecommended.input power.:(STC),`,„° 190, -:345(W -1:I Maximum DC input voltage .. 60 V IVIPPT voltage range > ` 22 —.38:5 V Operating range 18 — 38.5 V Mein;%Max. start Vol taget 22 —47 V Max. DC input short circuit current 21 A Max: DC input current 12 A Ground fault protection Transformer isolated 2000 Vrms input/output/chassis OUTPUT DATA (AC) @ 208 V @ 240 V Max. continuous output power 250 W (285 W extended range) 250 W (285 W extended range) Max. continuous output current 1.20 A,(1.3TA when 285 .W extended) 1.04 A (1.19 Awhen 285; W extended): Nominal output voltage/ range 208 / 183 — 229 V 240 / 211 — 264 V Extended output voltage range , 133 /,150 /166 -250 V 153 / 173 / 192 -mm V , Nominal frequency* / range 60.0 / 59.3 — 60.5 Hz 60.0 / 59.3 — 60.5 Hz Extended frequency: range .<' 54.22'-66 75 Hz 66.75 Power factor -0.8 to 0.8 programmable -0.8 to 0.8 programmable Maximum units per 20 A branch circuit 13 (11 when 285 W extended) 15 (13 when 285 Vd extended) Maximum output fault current & duration 1.6 A peak for > 10% of any cycle 1.6 A peak for > 10% of any cycle Maximum output overcurrentprotection 6.8 A 4,tt 6.3 A *50Hz operation; 50.0,/ 49.5:7:,'50.5 Hz 45.2 - 55.7 Hz extended range Bond Trunk Redto White for lm system EFFICIENCY CEC weighted efficiency 96.09% Peak inverter efficiency 96.6 Static MPPT efficiency (EN 50530) 99..5 W-,99.8 99.8 Night time power consumption 40 mW @ 208V, 80 mW @ 240 V Communication Power line (130.2 kHz carrier), Monitoring Free monitoring via gateway or online software Compliance UL1741; IEEE J. `std 1547 IEE std C62.41.2, CSA:C22.2 NO 107:1 & M R 22 ClassB' Compatibility 60/72 cell PV modules with compatible input voltage range specifications above Chilicon Power To learn more about Chilicon Power Microinverters, IA, visit chiliconpower.com Tech Brief f r•l / mss/ � %i' �, �:'�`' ��:. //.'✓�l-- i/ .5 1ff / 411 lliA WN// 0/1 �-��,,✓.�,/ ;;;fir „�✓`%����.; ���,�� �r�� :� r✓ 'moi' � ��� �✓/l / fes/ �i� , .r System Diagram . '— -^^ -.. _�...-..-_� r� �� rrt'—.r .--+r- ' �, r -�..�...�--.,.i—r�-.'. �.r- � e �- ,r^ ��-._...-- ,�-y...� f. r1'^"�r.^.r-.�/ "' `r••� Flush Mount Tilt Mount Ground Mount �XR1000 Only UFO/Stopper V Bonded Splice N/A Grounding Lugs 1 per Row 1 per Row 1 per Array Microinverters & Power Optimizers Enphase - M250-72, M250-60, M215-60, C250-72 Darfon - MIG240, MIG300, G320, G640 SolarEdge - P300, P320, P400, P405, P600, P700, P730 Fire Rating Class A Class A N/A Modules Tested or Evaluated with over 400 Framed Modules Refer to installation manuals for a detailed list. . - ;. ` i PPP --I... `!' \� \ _ y \F' VL. V I - \I ., y / ♦w 1 y AI I o 1 j( �- .. 1♦ �F'- Y - Ci �i l f —_�� v - {F I I "l �A" \} :i 3 7- Si r E -- - ;ti 1, OUFO Q Stopper Sleeve • Grounding Lug Bonded Splice --J- Ground Wire 4 Approved Enphase microinverters can provide equipment grounding of IronRidge systems, eliminating the need for grounding lugs and field installed equipment ground conductors (EGC). A minimum of two microinverters mounted to the same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. UL Certification The IronRidge Flush Mount, Tilt Mount, and Ground Mount Systems have been listed to UL 2703 by Intertek Group plc. UL 2703 is the standard for evaluating solar mounting systems. It ensures these devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor environments. Q Go to IronRidge.com/UFO © 2016 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.10 Compatibility Feature XR Rails Flush Mount Tilt Mount Ground Mount �XR1000 Only UFO/Stopper V Bonded Splice N/A Grounding Lugs 1 per Row 1 per Row 1 per Array Microinverters & Power Optimizers Enphase - M250-72, M250-60, M215-60, C250-72 Darfon - MIG240, MIG300, G320, G640 SolarEdge - P300, P320, P400, P405, P600, P700, P730 Fire Rating Class A Class A N/A Modules Tested or Evaluated with over 400 Framed Modules Refer to installation manuals for a detailed list. . - © 2016 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.10 1495 Zephyr Avenue ®ld I RON RI DGE Hayward, CA 94544 1-800-227-9523 IronRidge.com Attn: David F., Taggart, VP Products, IronRidge Inc. Date: March 28th, 2017 Re: Structural Certification and Span Tables for IronRidge Flush Mount System This letter addresses the structural performance and code compliance of IronRidge's Flush Mount System. The Flush Mount System is a proprietary rooftop mounting system used to support photovoltaic (PV) modules installed in portrait or landscape orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum XR Rails and secured to the rails with IronRidge mounting clamps. The XR Rails are side mounted to a selected roof attachment with 3/8" stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core components are shown in Exhibit EX -0015. The IronRidge Flush Mount System is designed and certified to the structural requirements of the following reference standards for the load conditions and configurations tabulated in the attached span tables: • ASCE/SEI 7-10 Minimum Design Loads for Buildings and Other Structures (ASCE 7-10) • 2015 International Building Code (IBC -2015) • 2016 California Building Code (CBC -2016) • 2015 Aluminum Design Manual (ADM -2015) The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for the respective loads and configurations listed, covering wind exposure categories B, C, & D, roof zones 1, 2 & 3, and roof slopes from 00 to 45°. The span tables are applicable provided that the following conditions are met: Span is the distance between two adjacent roof attachment points (measured at the center of the attachment fastener) 2. The underlying roof pitch, measured between roof surface and horizontal plane, is 450 or less. The mean roof height, defined as the average of the roof eave height and the roof ridge height measured from grade, does not exceed 30 feet. 4. Module length shall not exceed the listed maximum dimension provided for the respective span table and module width shall not exceed 40". 5. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush Mount installation manual and other applicable standards for general roof construction practice. © 2017 IronRidge, Inc. CA Flush Mount System Certification Letter - 1 ' AML I RON RI DGE 1495 Zephyr Avenue Hayward, CA 94544 1-800-227-9523 IronRidge.com t The parameters and adjustments allowed in the span tables are defined as the following: " 1. The Flush Mount System is designed as a Risk Category II structure as defined by ASCE 7-10 Chart 1.5-1. 2. When designing with a roof slope not listed in the span tables, but no greater than 450, the lesser of the two span ' values listed immediately below and above the desired slope shall be used. For instance, if one is designing to a roof slope of 120, use the lesser of the two span values associated with 101 and 150. 3. The wind speed selection shall conform to ASCE 7-10 Fig. 26.5-1A (Risk Category II wind) and any state & local county/city amendments to the IBC. No special wind topographic features are included in the span tables and the topographic coefficient (Kzt) is taken as 1.0: 4. The snow load used in the span tables is the ground snow and shall conform to ASCE 7-10 Fig. 7-1.' If a more restrictive snow load is imposed by a local building code/amendment to the IBC, such snow load requirement shall also be complied with. If the local jurisdiction specified snow load is in the format of a flat roof snow load, it shall first be converted to a ground snow following the local building code/amendment before the application of the attached span tables. No special snow conditions are considered including unbalanced, drifting, sliding or ponding snow. Snow load conditions presented in the span tables do not include buildings which are intentionally kept below freezing, kept just above freezing, or unheated. 5. The span tables reflect the ASCE 7 prescribed earthquake loads with the maximum magnitudes being: 1) For ground snow no greater than 42psf: SS <_ 2.Og for Site Class A, B, C, or D. 2) For ground snow greater than 65psf: SS < 1.0g for Site Class A, B, C, or D. 3) For ground snow between 42 and 65psf: SS <_ 1.5g for Site Class A, B, C, or D. 6. Roof zone size and definition conforms to ASCE 7-10 Fig. 30.4-2A. 7. Allowable span length in the charts may be multiplied by a factor of 1.08 if the rails are continuous over a minimum of three spans. 8. An array to roof clearance of 2 inches minimum must be provided. 9. The maximum cantilever length measured from the rail end to the nearest attachment point shall not exceed 40% of the allowable span provided for the respective load & configuration condition from the span tables. 10. No rail splices are allowed in the cantilever, outer 2/3 of end spans, or middle 1/3 of interior spans. 11. For shaded cells of the span tables, UFO Mid Clamps shall not be installed closer than 20 inches to Roof Zone 3. 12. When a roof attachment listed in IronRidge's Flush Mount installation manual is considered, the span values provided in this letter can be adjusted using IronRidge's online Design Assistant by checking the capacity of the selected roof attachment against the reaction forces provided in Design Assistant. © 2017 IronRidge, Inc. CA Flush Mount System Certification Letter - 2 1495 Zephyr Avenue /� IRONRI'DGE • ., Hayward, CA 94544 1-800-227-9523 IronRidge.com The span tables provided in this letter are certified based on the structural performance of IronRidge.XR Rails only with no consideration of the structural adequacy of the chosen roof attachments, PV modules, or the underlying roof supporting members. It. is the responsibility of the installer or system designer to verify the structural capacity and adequacy of.the aforementioned system: components in regards to the appliedor resultant loads of any chosen array configuration: r Sincerely, 9i:OFE3sj C 8o8i9 0 ILP F CAUf 0?/2�-��7 Gang Xuan, PE, LEED AP Senior Structural Engineer © 2017 IronRidge, Inc. CA Flush Mount System Certification Letter - 3 - • ''.a a !� ' ' a• { - - `f * 'x� � � � � _ r - •_ ,� a ��'�' • ''« • N $SI^<o 44 11=$Q�000ee�$SvQoeee�S9�600eo�$�N00000�$9�^« « ^<�$��0<�o8�$�Sioo « ^^<�SM S� i six"_, $,^<oo�,����3S�000���e$NQIoIoNNNe$�'Io�o���le e$9 m e$u,o^« m em 0009m 9R9000���e - s S;�Soogm �m$�QQaNNNe$�Qolo����5; elo����$�eeo���� ��$�^<^«.=9A;;^<So�,��e�^<^^«���e 5t E, Au,^<^«i;-.a$;^<Il ^<e���e$�,^<^<eu,���$�,eee���o$�^«<����$�,<eeu,���9u,00<u+,�'m°e j m =� Hn -4Hn ?E+. E': •'•--a a 0 N$� N$`m°e,��$� �$`m°e�N$N N$N,^o�Y^,$N N$�e.$�^,$N �$�e$^n$� �$� �$� �$�o`�^n$n �$��$�$� �$� m m .^,$� e $� GIp N$N eZ8p �$I m ea: 5;N mm ot e�$� ul$�^�$� N9e ee' �5; m e� Z89GC$���^G$$G $n��$I,mo6e�$�nm°mes -.SS -r,, .122G oi3ee6loll8e83eenev^III --m�559e •- I r u�+" o ♦`6 e�3� Looe e�oo een e9�1,^o,mo en,n eQQffi mm ,^092.^o.mo',S,°o^6,"d$$ee$��'SeB��" nonmo�,Q,"o,"o,"'o',S� st n , n -a Era.. e�9e m,�,x62o g n I$19^e�9 a RR�e����m'^e�eSE��u, �• n$ n �y mon^m�oe Flo^ ^o�n n$n ^o�o91IMPR.^o^o�oe dv m$'n° 9".3m n$n °".d'SS{� °i�m�� n$m�$u�'��e �'.23euuu�nnm^ d �$$$�� �SZ���.•m�'•• mw C.^m$n m�m�n n$m m��� m$mwm on or 6g�m^ e$momomoe��� m399 ^$m 88-1, nim oo«v mnnnn�nnmmm�SlBee��m$Susie^onnnm^n���^n��Fmm.„9$XnnnnR��nnu^PlP m$F3m m�m"91^m$$^mm$mBo W$$W mem m$$a^o m`$^m^m$$$n1m$� .•om °'�6 6`.8 ^.n ,^o $'3 ,moe$�� ����mmommmSSmm$m&mm$$I��o��mm�Sm-mm�mm����0�$�m�3m��°mmPP°°���"mm��������"������ ” a mem ml&^m&omlm m3tmm8mldl$mm m5l8mm�m'Rmimm$Sm��m� nln $mm$o o m$��6 6BnO nX$mummm�n� •� ii � om alb n na n m$mmgm�ommaa5t� n aT�m�Imm�maam�5ta nXlaaa$���PStP m$$�mmbt�° 3m>3mm��$�^ �I��BSP>3F3P o8 . .80000 1+-- t'5;1*1m�o�Ig�m .1-8§8-80o-M ^o'8goft*,%,am.a8o - gio - - - - - - - - - F I 1no177 rSlm on4no r9mS 1 2292.1 of IR1�o�Qr lo Rm Hl -�rmHno mem omorRm -a 78 2 NE - N 'I H .y ..- ... 0 t .i N N .•I "i:.a f � 1 ♦ ' at • 'h Z ' F �,a , „ �.t� i` t * .� ; , }i • - •.±r t �.16 •�, a. 1 �� ♦ � 4 r h � +, ri. - _N 4 4zTTICN I SON BQ000N$sI No«on< $�Noo<QoN$��,Q000eN$ <^<Iooe8�I3S�;0000^^<oNNoSSSSoo�N O YIS +0 N$$NIQQQQQN AIS N0000IN$$N TIT ooNSlSNl==zN$$Ndldd4dN$NNnv«<6N$TNn««nv<NmNe00000".m C NNQQ ONNvnlb Sim OO OuNiumtunib $uni000 vmmo NZ+HIf SII W Jml Jnib 11 Jf V1v voNNJmlu c v v v vv�l umlN� O vO00a Vrvl uml uml0� aaazw1= l N N unity $ N o o< N N unib $ N O O< N N m m$ N v e v N N N Q$ N e e v O Imvvvvm v i%iNO00N Vm1Nb $N V O V NN;nilb ANDY V NNunIN �N000NN Vn1b �N000NNNN�NO00NNNm 9iN000NNmr; $;! a <v oNvmiN$IN vvv v�$vni ".,2 G 1 N un1$NNJi$mmm ISIS Nurvi$mmm unl$NNrvi1$mmmN$NNurvl$mm$NUN1N Nrvi1$m$uvP mQIN Nmrvmmmmmm $unlet c����N$mN i$NNN$�n�NI�NNN$�e��l$NNN$Nn�unf$u�iNN$umimmN$NN�$mm$�$NNvrvi$vmi r;`�un�$NNvrviNNNbvni$NNurvi umi $Iuniu�I$NNvrvi vrvi$mumi 1 ,- uni$NvmiNm,ua mlvni$NmNmmn wlniSiNm�mmO NunuRNm�Im $b Nm$N mamNNNNN;n ,S u7S vP m$vvvvoNvni �imovSSSS$uminN q; _ Al I A$N o. AeN8W$2 $Nmm NN5t$$N$m �-. uni$NmNm min mN$NmNmmrvmN$NNunim mn bvni$Nvmi vnim$b buns 9iNmunimNmm uni l$Numi189SeNl$NNNNIe$Ni$NmNrI$ie muni 9iNN9im Nm t N��mNnonln nol�$I$m��nn$e TlN bnonn vPi��mvmi m0`m monNmmmNb$bnNNNNNmmo me v0000�e$n00000en�NN OI����vniN mb QI eaOeee�In ee��eN6nn6e33l�mo6�neN$$Imem�;�6,mo9�me$6�eN��mmNNNNm��9��$�m�6�mN��Num,I$$$N�Nme ri E ve8�m m m �fn6lN��m n m e$$Im m m e�I�IeeNel� e��me$no 633�m bete e��m�e$6^e��eN�e ele��el.^,NeN ?_ Yg W oon mob n$$N 399m,N�SSN,3��nm eNe "e FF&�Sme� c a'"-_ _ wNoe moneoano n$n 6Nu; 6NNnnnNmn 6Ne N$$$N m$33,moNee'" NSiSiSmn�oue �No mon12o 1NP 6Nennnm eNN�nnmOn6Nem 6NN6 eNeeleN��NNeN e�eeNm3meN -- n��m�� m$$NNN$nn$mNVi�Vi uminnnmNmmmNnnnnNurvt urvt urvf urvibnnnOQly vobmNmOOOOONmNNO����NNbN — Mann= lood�annnnnWsnannnnn�;nn���nnn������nnnnNN$$$e��n�Nsss���em���NNmNNNxx$N���� m$ n n m arvp m m S n m$ m m n n m m m n$ m m$ O n v N m m N 0 + m$ m n _ ai`mnommno mm $N N$n me3Nm$$N nm N NO• CmmmOm O QmmN oSSOSNe VV _ - m$$m mmlm m$$m mSn nfl,�$uNNn n"dN$$$n" m339ffiu$Nm N$$$N mOO R208=282=2BI 1021T 20Nnnon n8m nNn nN; ngnp°80n n$NSb __ - 0..00mm mln bu3 Dnp 99 .1 5i N$N1. N$ 8mmvmio3$marv0 ut vlO mOnblb t�O <m�N 0����mo j ry mmiN NDN m$v3mmmmNN nmm nnmmmm nnnnnm$mm mNNm V;nnnn 1�N$$$nnnn umimmmmnNum KI Nununi unim mt�NN N$$$Nmpbbb mmTmN+41NmPNNN+mNmm8i 8i�mm itsBiPPNN�mWm$�nm �Nnmmmnm0m�nnnnmm�nnnnnOOnnnn��Nb Rmpmm., I bST N$N N$Nmmo3NmQmN$ISImNm momv v��ININoSSSSb r m=mmmmm'Nm$���xN�N°msnnN���nnnnnss�m�bb��nnnna�$$$n�nn�m���n����������NN„$$$�eee; =I Abin .moi ."i .`i w �Nmarr i^�o,o,o�$2�o�BaamNmoBmmNow�5t3SmSNmmoo$NDN;9'�nnn.1.1mSN�mgAnIInn���������NNee Im .r ti l Om,om __ _ OmOnmN ho nRN nRiry AiNv OnOn siNv mOmOn niN .mi Ri rmi�n rvmiNO nsiN Note: The regions In the gray shade denote an additional Installation requirement on UFO middle damps. Please refer to Note 11 on Page 2 for details. flush Mount System Spin Table (inchor) , YUI 11813 In's'ldllaliuu tfvlaabu'uw fvluJule X70 opal � 1 mwuu dllUW. U psf - 16 psf 16 psf 30 psf 41) "'d 50 p'f 60 pA 00 psf ^^.rsf SPeed (mph) slope (dee,.) Zone 1 Zone 2 Zone 3 Zone 3 Zone 2 Zone 3 Zone 1 Zone 2 Zane 3 Zone I Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 106 80 64 98 80 64 83 80 64 81 80 64 73 3 64 67 67 64 61 61 51 57 57 57 54 54 54 51 51r47 30 110 83 65 % 81 65 83 81 65 80 80 65 70 70 65 63 63 63 57 57 57 54 54 54 51 51 51 47 47 15 108 80 65 95 80 65 80 80 65 76 76 65 67 67 65 60 60 60 54 54 54 51 51 51 d] 47 47 45 4520 106 7965 95 79 65 80 79 65 76 76 65 67 67 65 60 60 60 55 55 55 51 51 51 47 47 47 45 45110 25 105 79 64 95 79 64 83 79 64 77 77 64 68 68 64 61 61 61 56 56 56 52 52 52 48 4848 46 4630 93 91 91 87 87 87 76 76 76 76 76 76 69 69 1 69 63 63 63 57 57 57 54 54 54 91 5151 47 4735 92 90 90 % 88 88 78 78 78 77 77 - 77 71 71 71 67 67 67 61 61 61 56 56 56 53 53 53 51 5140 92 89 89 89 89 89 81 81 81 8o 80 so 75 75-70 70 66 66 66 61 61 61 57 57 57 54 5492 . 88 B8 91 98 88 83 83 83 83 83 83 79 79 79 75 75 75 71 71 71 . 68. 68 68 63 63 63 60 605 10 101 105 ' 103 76.. ' 77 77 61 63 ' - b2 98 96 95 76 77 - 77 61 63 6I 83 81 80 76 77 77 61 63 62 81 76 61 80 77 63 76 76 62 73 73 61 70 70 63 67 67 62 67 63 60 67 61 61 57 54 61 57 54 61 57 54 - 57 54_ • 51 57 54 _j1� 57 54 51 • 54 51 47 54 51 47 51 47 47 45 4715 45 •20 102 76 62 ��95 76 62 80 76 62 76 76 62 67 67 62 60 55 55 55 51 51 51 47 47 47 45 45 45 115. 25 100 75 62 95 75 62 81 75 62 77 i 75 62 68 68 62 61 &6161 56 56 56 52 52 52 48 48 d8 46 46 46 30 90 87 87 85 85 85 75 75 75 74 74 74 69 69 69 63 57 57 57 54 54 54 51 51 51 47 47 47 35 90 8686 86 86 86 77 77 77 76 76 76 71 71 71 66 61 61 61 56 56 56 53 53 53 51 51 51 120 40 30 15 20 25 30 35 0 89 89 97 101 99 98 97 87 87 86 86 8 73 74 74 73 73 82 % 85 59 60 60 60 59 82 87 89 97 95 94 94 94 83 84 86 86 6 73 74 74 73 73 83 83 83 86 85 59 60 60 _ 60 59 83 83 83 79 82 83 60 79 79 80 80 79 82 73 74 74 73 73 80 79 82 59 60 60 60 59 74 7f BD 797979 81 81 81 81 I 73 59 79 74 60 76 74 60 76 13 60 77 73 59 73 73 73 75 HO 1 74 74 74 77 77 I 77 13 73 59 70 70 60 67 67 60 67 67 60 68 68 59 —68 68 68 70 70 76— 76 76 69 74 67 63 60 60 61 6 72_ 67 63 60 60 61 63 66 72 59 60 60 60 59 63 66 69 72-97 66 66 66 70 70 70 61 61 59 57 57 57 54 54 54 55 55 55 56 56 56 57 57 57 61 61 61 64 64 64 61 67 54 51 51 57*6L61 52 54 6 61 61 67 54 61 67 54 56 57 63 54 51 47 47 48 51 53 53 57 63 54 51 47 47 48 51 53 57 63 57 63 50 51 47 47 48 51 53 57 63 54 60 51 47 45 45 46 47 52 54 54 60 53 47 45 45 46 47 51 54 661 54 fi0 51 47 45 45 46 47 51 54 63 89 67 89 67 54 83 67 54 81 1 67 54 73 67 54 67 67 54 61 61 54 57 57 50 54 54 54 51 51 51 30 93 69 56 92 69 56 78 69 56 77 1 69 56 70 69 56 63 63 56 57 57 56 54 54 54 51 51 51 47 47 47 15 92 68 55 91 68 55 78 68 55 76 68 55 67 67 I 55 60 60 55 54 50 50 51 51 51 47 47 47 45 45 45 20 91 1 68 55 91 68 55 78 68 55 76 1 68 55 67 67 55 60 60 55 55 55 55 51 51 51 47 47 47 45 45 45 130 25 90 67 55 90 67 55 79 67 55 77 1 67 55 68 67 1 55 61 61 55 56 56 55 52 52 52 48 48 48 46 46 46 30 82 78 78 80 78 78 72 72 72 71 71 71 67 67 1 67 62 62 62 57 57 S7 54 54 54 51 51 51 47 47 47 35 82 78 78 81 78 78 73 73 73 72 72 72 68 68 68 64 64 64 60 60 60 56 56 56 53 53 53 51 51 51 40 82 77 77 82 77 77 75 75 ]5 74 74 74 71 71 71 67 67 67 63 63 63 60 60 60 57 57 57 54 54 54 81 76 76 81 76 76 77 76 76 77 1 76 76 73 73 I 73 71 71 71 68 68 68 64 64 64 62 62 62 60 60 60 5 83 62 50 83 62 50 83 62 50 81 62 50 73 62 I 50 67 62 50 61 61 50 57 57 50 54 54 50 51 51 50 ]0 86 86 64 52 77 64 52 76 64 52 70 64 1 52 63 63 52 57 57 52 54 54 52 51 51 51 47 47 47 ]5 86 86 63 52 76 63 52 75 63 52 67 63 52 60 60 52 54 54 52 51 51 51 47 47 47 45 45 45 20 85 85 63 51 76 63 51 75 63 51 67 63 51 60 60 51 55 55 51 51 51 51 47 47 47 45 45 45 140 25 84 84 63 51 77 63 51 75 63 53 68 63 51 61 61 51 56 56 51 52 52 51 48 48 48 46 46 46 30 78 M7373 77 73 73 69 69 69 69 69 69 64 64 I 64 61 61 61 56 56 56 54 54 54 51 51 51 47 47 47 35 77 77 73 73 71 71 71 70 70 70 66 66 66 62 '62 62 59 59 59 56 56 56 53 53 53 51 51 51 40 77 77 72 72 72 72 72 72 I 72 72 68 68 1 68 65 65 65 62 62 62 59 59 59 56 56 56 54 54 54 45 77 7 72 2 74 72 72 4 72 72 73 71 1 71 68 68 68 66 66 66 63 63 63 61 61 61 59 59 59 5 77 1 58 47 77 58 47 77 1 58 1 47 77 58 1 47 73 58 1 47L::::6:4 58 47 61 58 47 57 57 47 54 50 47 51 53 47 10 81 1 60 48 81 60 48 75 60 48 74 60 48 68 60 1 48 60 48 57 57 48 54 54 46 51 51 48 47 47 47 15 80 59 48 80 59 48 74 59 48 73 59 a8 67 59 48 59 48 54 54 48 51 51 46 47 47 47 45 45 45 20 79 59 48 79 59 48 74 59 48 73 I 59 48 67 59 48 59 48 55 55 48 51 51 48 47- 47 47 45 45 45 1S0 25 79 59 48 79 59 48 75 59 48 74 59 48 68 59 48 59 48 56 56 48 52 52 46 d8 48 48 46 46 46 30 74 69 69 74 69 69 67 67 67 66 66 66 63 63 63 59 59 56 56 56 53 53 53 51 51 51 47 47 47 35 73 68 68 73 68 68 68 68 68 68 68 68 64 64 64 61 61 57 57 57 55 55 55 53 53 53 51 51 53 40 73 6B 68 73 68 68 70 68 68 69 68 68 66 66 1 66 64 64 61 61 61 57 57 57 55 55 55 53 53 53 71 67 67 71 I 67 67 68 67 1 67 66 66 64 fi4 64 62 62 62 60 60 60 57 57 57 160 10 15 20 25 30 35 40 73 I 55 44 7656 45 75 56 45 75 55 45 74 55 45 70. 65 65 70 64 64 69 64 64 69 64 64 3 76 75 75 74 70 70 69 69 55 56 56 55 55 65 64 64 6a 44 45 45 45 45 65 64 64 64 73 73 73 73 73 65 66 67 69 5 56 56 55 55 65 64 64 64 44 45 45 45 45 65 67 64 64 73 55 44 72 1 56 1 45 72 56 1 45 72 55 45 72 55 a5 64 64 6a 65 64 64 67 64 64 68 I 64 64 73 55 1 44 67 56 45 6656 45 66 5Z 45 67 55 i 45 61 61 6157 52 62 62 64 64 64 66 64 64 63 60 60 61 60 62 64 55 1 56 1 56 55 55 57 60 62 60 44 45 45 45 45 57 60 62 6a 61 57 54 55 56 55 % 60 62 55 56 54 55 55 55 _ 56 60 62 40 45 45 45 45 55 56 60 62 57 54 51 51 52 52 54 56 60 5 1ad 54 1 51 51 52 52 54 56 60 45 45 45 45 52 54 56 60 54 51 47 47 48 49 52 54 57 54 51 47 47 48 49 52 54 57 44 45 45 45 45 49 52 54 57 51 47 45 45 46 47 49 53 56 51 47 45 45 46 47 49 53 56 44 45 45 45 45 47 49 53 1 56 68 I 51 41 68 51 41 68 51 41 68 51 41 68 51 41 67 51 dl 61 51 41 57 51 41 54 51 41 51 51 dl 10 72 53 43 72 53 43 71 53 43 71 53 43 66 53 43 62 53 43 57 53 43 54 53 43 51 51 43 47 43 IS 71 52 43 73 52 43 71 52 43 70 52 43 64 52 43 60 52 43 54 52 43 51 51 43 47 47 43 45 43 20 71 52 43 71 52 43 71 52 43 70 52 43 64 52 43 60 52 43 55 52 43 51 51 43 47 47 43 45 43 170 25 70 52 42 70 52 42 70 52 42 70 52 42 66 52 a2 61 52 42 56 52 42 52 52 42 48 48 42 46 42 30 66 61 61 66 61 61 63 61 61 62 61 61 59 59 1 59 56 56 56 54 54 54 51 51 51 48 48 48 47 47 35 66 61 61 66 61 61 64 61 61 63 61 61 61 61 61 58 58 58 55 55 55 53 53 53 51 51 51 48 j46 48 66 60 60 66 60 60 65 60 60 65 60 60 620 60 60 60 60 57 57 57 55 55 55 53 53 53 52 52 6 60 60 6 60 60 65 60 60 65 60 60 64 60 60 62 60 60 60 60 60 59 59 59 56 56 56 55 555 6 49 39 65 49 39 65 49 39 65 1 49 39 65 49 9 6 49 9 61 49 39 57 49 39 54 49 3 51 10 68 50 40 68 50 40 68 50 40 68 SO 40 64 50 40 61 50 50 4015 67 50 40 67 50 40 67 50 40 67 so 40 63 50 40 59 50 40 54 50 40 51 50 40 47 47 40 45 40 20 67 49 40 67 49 40 67 49 40 67 49 40 63 49 40 59 1 49 1 40 55 49 40 51 49 40 47 47 40 45 45 40 180 25 66 49 40 66 49 40 66 49 40 66 49 40 64 49 40 5940 52 4940 48 - 48 40 46 46 40 30 63 58 58 63 58 58 61 58 58 60 58 58 58 58 58 5 53 53 53 51 51 51 48 48 48 46 46 46 35 63 58 58 63 58 58 62 58 58 61 58 58 59 58 58 �Ws 6 54 54 54 52 52 52 49 49 49 48 48 48 40 62 57 57 62 57 57 62 57 57 62 57 57 60 57 57 7 56 56 56 .54 54 54 53 53 53 51 51 53 45 62 57 62 57 57 62 57 57 62 57 57 62 57 57 7 58 57 57 7 57 57 5 55 55 54 50 Note: The regions In the gray shade denote an additional Installation requirement on UFO middle damps. Please refer to Note 11 on Page 2 for details. a: ':3l: aa:3:'.3.1a :S: z :S:as:3l: :3:aa.S. 1 3:atR a: as:3:':3:a a::: :::aa:3: :3:as:3:':3:as:3: :3:as:3: ::: ::: ^ - :3: :s: :s: :s:Ias:a: - aa:sl: - :s:laa:s: :s:N s: 3 s 1 al$s:33: 7a $s: sl3: : a$ s: 33I: :: a$ s::1 S:ss: 7ass:33: :5;$s:339 :I: S3: I n s: 3 3 7 7 a$ s: 3 3: 7 S$ s: 3 3 9 a$ s: 3 3 T a$ s: 3 3 7 9 a$ s: 3 3 7 Tass : 3 3 ma s: 3 3 9 9:337 :ass:ia: IT A N st 3 37 71„9:339 7S$s A s 2.143.11. S7$s:ss: 7a $s:337 as:337 77 as7 :77 rs:I7::77 - :97 aaal7 ::77 aaa aaa :77 aaa7I::77aaaaT Z :77 alsaa :971991 :77 aaa ansa alai aaa alai ansa Maa ansa aaa'aasassala aSsaaaaa 1199191 aaa rlsa:9S99a --aaa ala as aaa ansa aaa aa tit a aaa aasa aaa aaaa til aaa --Asad„ aaa aAs82111 asMlMaaA aaa alga-aaa- 1111111- 1111111- aaa 1111$aaaaaaaaaaaa-aaxsaaaaaaasMaMas r_ — t-. a Y S $aasa �a$aaFs� aaRaa$ aasaaaaaasaasa 1111 :9s77x�aa L C . y g n QI tR°^'aaFa$ as s Fa$a rls MaaFa$ ala $aaFa as$asRa$$$s$aa3a$NNaasaaa$ aSR$a$RR aaM°'aa � e a E v as a$aaFa a$aaFa11$11 axs + R 2 1171 1$111$ a$a 11$11 E I.I.I Hi! a$a aa9FRsaaaaaaFF9saaaasrRaG G aaaRsaaa^ aa$FaaaaaaaaRsa asaa$$:7777saia o a � aaa aasFRasaaaasFGa$aaasaFF9aaaas7FRaiaaaaaRsasaaaaa$FaaaaaasaRaa - aasa �saa$ .` ^I 9 saaaasFR s s a a a 3 aF R sl s a d a a$ FF 9$a a a a F F s s a a s a s R i g s a s a s s$F a a a a a M m saaaa a$s -- a a a aSaaS t' I I I I It o ^ ^ 6 SRRFSFs2KARRFA Fs: FFRRRSRR:$$ 8„$FSGs aaa" RFR": t" a$FFRa as aaa$FF sa^asS a$ R :39991$ a SR R;.,`. F SS °SRRF FS^<'°SRRF RRo'°SRRFF F9RS R R F R F RF RF R R R$FFR Sa s$$a$F 2 2 2 affia$Rss$°'$a$^ - � ARRF F93 R�'.RRF FS: �°3RRFSRR^e '°SRRFF FSRARRFRRF RRRF$FF FRRFa$FFRFRRFsa$F'^°R$$Ra$a$ R F S: a a 7$ F F s a a s s a$ R: :1 7 7 9 3 9 a Tn ^ n ' F R R R R F R :: F R R R R R k a i F R R F R R R R F RFS F K F R S F F K R R F F R R R F F R s a aaa 3$FF aa a s RR FR RFeiF Irr FSFRRRRFFRRF RRF H -I a III I ; I P 9 9 9 Fffia$FFIFF Fsaa$ = j � q R R R F R 7 ;, a a R F F F R 3 9 7'$ a a$$ 3 :: 2 a .,G aaa a A s a a s F F F R: 1.1. 79 s s a a b aR797 as 7272S9 91722 4 397' 2 2 G :S SI::S R 9 9 9 A Z 2 2 B R F F R R R R R R a a S a9R R R 3^ 3 329999R5tS$ $ssa-- ~ I A P s 0 9 o 1. 9 9 8 o S$ S : 9 s E S S S 9 e a s 0 9$ SI:: 9 a s o S E e ;, s$ 9$ R R a : 9: ^< R F R R ^e o i o S RIR ^ e S R R F F^ S -.9 ts s s a ts a s E i a a a' a l a s Ila ^ a S R R a a a a a S s a a s F F F R: 7 9 9 9 a s a 6 aid =8w 76R,a77Sa oio aSaB$SR RRRe: ieRF RRaSRRaaSaa aaFFFRss$$ss9a _— — l�98eeE^e ^e8s8e588$g;,=�^0 �8;, a@SSeia-;,g 8E28ga^ aa;, a79aRRRR ^e oio °RRRFaaRRFFFF 8 _-RrAAS7 RPt t2 9rA V __2 r9 AMS9 _ IR t2 4 4 A 27RgAA39 NAmS7 EL 0 0 0 N E :3 T ^ Ida :: a : a : : 3 : : 3 : ^ : 3 :: a : 3 : : 3 a : 3 : - : 3 : : 3 : ^ : 3 :: a : 3 : ^ ^ : 3 3 : :S: :S: :S: :3: :a:3: :3: :3:^ S^ _ %x:33: :alax:SS: alax:S3 :ax St 3 :axx:33. a:^:SS: aa::S3: n ^ x:33: a°^'x:33: :ala x:33: axx:33l:::axx:33: aax:33: ax:33: ax:33::S a:l: S3: x: 3 3: 9 a x x: 3 a: a x x: a 3: o a x x: i i: o a x x. 3 3. a a x: i i a a x: 3 3: x x a 3 3 :: S a a x: i s 'C ^ :3: :9: aea s: xxa :3:aa^^ :93a :33 0 5 aaa :9: aea :S::asa :9: as^^ alaaa ^a ala a- aa:-aaa- aa:-aaa:axa::aaaeaa aaaxas::ssa - aaaa: aim aaa C aa: aaa aa: aaa aaa aaaaaaa::aaassaa: aaaa aa: aaMM::aaea xx:xxxx::aa aaa aaa aaa aaa Vaaa aaaa3aaa aaaeaaa: aaaxaaal: aa: aaasaaa axaaa aaa - r v � - a3lR exn n a S aaSa xlx a3: ae aai z N aa: x36^ u c axe Fax aalR^„ xlax-Msa alaxaasax xis GS St m :aaa„s: ase^ aaaxs:lxxxxa g .QED aaRax aria alas :sax axaaa axaaa asaax aaaasaaxigax sea 2 as a9Fa3 22 233RA8a3931 RFaaaan aaaFa aaas-.l:aasaas: 4 a a v xsaa: xe3^ :aaaa 'o = n �'3aa a 33 3 a a a a a 3 99 a as G a3aRF3aa 2 2 Gal 2 G G a 2 as S x 3exa a 31 x8a3a xseox x xxaaaa N c � .` _ kala aaaa 1FFaaaaaaaR33aaaaa6 R F Sax aa3F33aaaaaaS3S aeaaa3aaaaxeaa3a xsaa aeaaaxs t d ^ _ 3aa33F3FSa - RRela8SSRF�Faaaaa3lRF�'. as aRR9e:$:aaa3: aaaa:ue>w: ^:aaaa t ^ ,e n RRF F S R S R R F A R R F R F S F S R s a a a R F 3^a a as a 3 R F S e Sax 3 a a 3 a as as a :s:a xxxa33a - E 3 R R F F S° 3 R R F F R R R R F R F R F e a R R F 3 R F,' R F R R F S 3 R F R F R S R 3 a a S x S S 3 S a 3 3 a S 3 11a 3 T. a a a a x e a a SaaS FS a a 3: ssleF FRa aSRFF^ aaRR3::33Sass 4 a 4 aaa: aex: :aaaa .- 0 FFRFRCeFFFFn RlR 3FF3FFFFR3RS33 S R R R a 33 a a a a R R x s s s x a a 33xm N xaaa ^^:3:xxx x a aaa n FFFa K P ARIRnFFF R 91111saRrRRRRa3aaSS33Saa^ xs:Qi Sa S HG� :I G eases: aRRF FFR 3::335333: Sia: :s :aaaa 0 a: 1.2 R R R C I”. ,`.lF F P. P R S 3 3 R R F R G S a a a a R F F x els e x S SIT 3 x a a a a S S mi 3 a a a a a : 9: x x x x a a a a _ S a$o3:13sa3axS34 alx:aS9 1 2 :3::13 a3RRB3a: :3F R9::3RFF FSSSSSFFFF SIS all a33a as - s 0 Sa aaaa9S3aa x36 o3a8a8:aa xaaaaRRl^. FI::ISSa a3: 1 a a 289: :s'R:7 7 :aaaa - b - :9S:xS3 RicRFR3e :aa: 39S33RR aaaa x e e 9 x S 333xaaaaSSaaa ae:xxxx3aaa .,m E S9=sea :.x^s_ o93ao8xa :aaax:-:s a36:aFFFRRa:3RF FF3F;:KKRSSSSF FFaaaa a 33a — - Rsxa< �smae _.a„xis: __ �xms. RsTsa Rsma< rams; �xmae rams: a x:33: Sadx:3:1 Sd 51 SaN5t.3S. :ala ^:33 '^°3:33: :1:13 ^aa��S;:a mX9 e x: 3 3: S s x: 3 3 S s x 3 '" a s x: 3 3 '" a s x: 3 3 x :: 3: x: 3 3T a i 3 - :asx:` 3 1sx::l:l:^:Ssx::l3l: :Sax: sx:aa siS r. s:_2 -@;:^aa a _ a aaa adsasaia aas^„a:a: :a'N°xa x:: :dx ^. SS: 11. --++ i sR to a:::a sasaSa aI sR 83 „::as ada aia:: aas ala' sxsF�,: A 3: � I :ass3:a: a3M Y^.3:' a5; A n 3 F'S r: ala s^ aI::d 00 - ---- - ------ -is v � Nn n m G as n n n R asxa rias: sss5 a:: ^eis s5'aSsR'.^,assAv:R'l- W a assas$as aa$a asasNssasas3s Gas :aq s9'��°'°' :Sss: S'S a r � n� � � asM xxassa aria -asax: asa3a a3N 33a aa3xssx� x33 N E >s a a S S a a R R 3 3 3 a a s s R N 3 3 a a s 3 x a ': 6 a s s :: S S S s a a s 3: : 3 s a a: N 3 s s S .�, € R A w s s s s S R R a i i N C _. �'ssa a3aR�3s a a a: s s R s s a G s 2Fa3a as33s s 3 s assts s3xa rsNs S.A-'S:2 Siaa a m; a a 3 a R 3 s a a a a s s g s s a a s S,- s s a ala 3 3 3 s a a a s a 3 s s ala ^ a 3 x a 3 3 aG 3 89 a x a= ^ -- saassRRi(;as3x as 3 NssassRRI-- ra R R R fi 9-- RR s ss ssas ads ass.^, -_ dRRFRR SR mRR�sR �'S '°�RR�sas�RRssRasa Rssssaaas 3a^ asaaa 8•€r:s s3s3a sS:aaasa33 sass: lRax33aRR3 „sRR xaa a3R1F:33 Sasaa33 :aa :sxs„SS€S sssSA maaaN "v r KS SRK' �RRI; SIR 3s s 33s R R K ai as a3R ss ssas s ala sss e_S s6 Sl5_S 'sSaaa RRPRRKRRR SIR RSRRR asRl�^- �Ssa FRssRa a3sssss:a3 g. a.€sas3aZs as :9 51 8:a3s: n33xGRxxiC„lse RP'^°xa "�l�lC� SSssaaSSl3 '"Sia :sssss€€4RG^ss s3'rR ;.maaa - d g RRSSI:^ a r R R nR R'x x>; 3 s$ 2 3 ri 9! aaa �l�^.��3s sss 3s3Z, 1Sa 3n a S ax:3:l:^ axs3A Rs:: x: RS: :aSIR :x IC P! 9 A Ps3333 RRsa sa E'a;s ax asr aas3sx d sarisl: 3: 5t5tr2: sR sls s::RR�sxa ':s3 3313 aa33 38a :3ssss 9-9 °', .^„^ mS3'^,^aaala a a c R R RX X 9 2' 9 R s s s s s R R P a 3 3 a a P p ;z s s s s 3 s 3 a a a s '^ p a x43 a s s s P P.S S a S a a a a N` _ s 3 S s a^ : d _ R X a d a: : x d m s x: : S a : a : 9 R R ✓; C .^. ^ s 3 s s s n R R s a a s 3 3.c 3>s a a s h °„` 3 3 3 5Sm$< :AmSe - �xmse �AmSe IF -- 5x�se SxsFo - #AmF: :Rm$e IV, PLAN VIEW EXHIBIT: EX -0015 - page 1 of 3 -03/16/2017 Aodule Mounting System Bonding Mid Clamp XR Rail =S ie DETAIL A Module Mounting System Bonding End Clamp PROPRIETARY AND CONFIDENTIAL - TRE OIPoRNATgR CORTAOIED DI TMS ORAWWG B WE SOLE PROPERTYW OMRRWGE OIC. ANY REPROWCT0W PI PART OR AS A WROLE WDRODT ME W 4R PEMSMR M ROMICOfF OK. 6 PROMROEO. ' (L) 0.4 X L ( MAX) Span PV Moc' ' XR Rail Roof (By Otl Existing Roof Structure El% , . A _ _I. A _ DETAIL C EXHIBIT: EX -0015- page 2 of 3 03/16/2017 Module Mounting System Bonding End Clamp PV Module 0.4 X L ( MAX) DETAIL E Rail Attachment (FlashFoot2 Cap awn for Reference) )dule Mounting Sys Bonding Mid Clam PV Module ling ' Shown for ince) DETAIL D. Jule Gap (P) Module Fla (Flas Shown foi ;EXHIBIT: EX -0015 - page 3 of 3 - XR10 XR100 XR1000 FLUSH MOUNT SYS • SIZE DWG. NO. EX -0015 SCALE: NTS WEIGHT: IA em ^F' � L{ '� .+. •4. f.1_ a •fy ,t t • "1 �. n4 f.''' •' i..[ •'!. � T' • s'*' • •• LABELI _ N1 16 -"DIAGRAM-' M • L LABEL # 1 ` . . r.. i ARRAY CAUTION: • . CIRCUIT r t; W/MICROINVERTERS LABEL # 2 .r - PV . PHOTOVAOLTAIC LABEL # 1', SubPanel DISCONNECTAC OR • .. - 'tet , .t AC SOLAR DISCONNECT LABEL # 2 & 3.r Disconnect ' '� .; _ x ` •fir. • . - s 1 .t .: LABEL # 3 METERPHOTOVOLTAIC•• ,. RAPIDWITH SHUTDOWN r MAIN LABEL # 4 I ` SERVICE' LABEL # 3- —� r >, PANEL ``. WARNING ' • • " SECOND•URCE IS PHOTOVO •� .. • 4. _ •' y _ ..1. .. r ,_ =i ' d ,..,* _ - M � c Pry GENERAL NOTES: ,. THE FOLLOWING DOCUMENTS ARE PROPERTY OF RENEWASLE DESIGN _ ' _ PROJECT INFORMATION: PHOTOVOLTAIC PROJECT INFORMATION: SOLUTIONS. ALL DESIGNS AND INFORMATION CONTAINED WITHIN THE - ' �. 3.42 kW (DC) _ 3.00 kW (AC) .. f( xr _ DRAWINGS ARE THENLY ME THE SPECIFIED PROJECT AND SHALL NOT BE - - 'I YSTEM: 3.42 kW (DC), 3.00 kW (AC) PV UTILITY INTERACTIVE SYSTEM ' — USED FOR ANY OTHER MEANS. USE OF THE DRAWINGS FOR ANY OTHER • y ^ � �a• -_. --._.._,�.., ' y'� • ` 't�. PHOTOVOLTAIC UTILITY INTERACTIVE SYSTEM � ' PURPOSE IS PROHIBITED WITHOUT EXPRESSED WRITTEN CONSENT OF .._. _.,.__. fi - RENEWABLE DESIGN SOLUTIONS. - ' _ - PROJECT; j CLAIMS EVAL, INC. - BRADLEY REDBURN RESIDE 2. INSTALLATION TO BE IN ACCORDANCE WITH THE NATIONAL ELECTRIC . .wr h; - - ;; r - PHOTOVOLTAIC PROTECT • ' 134512TH STREET • LLE. CA 05965 CODE AND THE AUTHORITIES HAVING JURISDICTION. _ • -": - ' _ _. _ AHRJO BUTTE COUNTY , 3. IN THE EVENT OF A bISCREPANCY IN QUANTITY OR SIZE OF CONDUIT, •� ♦ N rp * _ - NCE 1345 I ZCf Streel PGBE'• " •- Z UTILITY: PG&E WIRE, EQUIPMENT, CIRCUIT BREAKERS, GROUND FAULT PROTECTION + . K - ,� - AHJ: {BUTTE COUNTY SYSTEMS, ETC. (AL1, MATERIAL), DEPICTED ON THE DOCUMENTS OR f[ - _ - • 1. y - - •• SPECIFICATIONS, 714E INSTALLATION CONTRACTOR SHALL BE f_ 1 ; [ �� - - - PROJECT NUMBER: - RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND wW' C16, .• r . �r 4•"R _ .. _ r. 3H ET IND .: % - ` 45523-113 s y SERVICE EQUIPMENT IN COMPLIANCE WITH ALL REGULATIONS, LAWS, OV' I'�� r^ � ,.s . _.ORDINANCES, OR AHJ. / ' . 4. • IN THE EVENT OF CONFLICTING REGULATIONS, LAWS OR ORDINANCES, 162 - `'l. - PROJECT SHEET. r / / M-1 PROJECT LOCATION AND COVER PAGE • THE MOST RESTRICTIVE SHALL PREVAIL (� T WII-� i�.�' - •! r• • - !r %fires � -t L-, SITE PLAN b. ALL ELECTRICAL MATERIALS AND EQUIPMENT SHALL BE NEW AND LISTED 1- h L-2 STRUCTURAL DETAIL BY A RECOGNIZED RLECTRICAL TESTING LABORATORY. i J +' 'I � ,, j• SHEET TITLE: - 6. AN INVERTER OR At MODULE IN AN INTERACTIVE SOLAR PV SYSTEM _ E-1 MODULE STRING DETAIL _ - • SHALL AUTOMATICALLY DE -ENERGIZE ITS OUTPUT TO THE CONNECTED E-2 .' 4 1{INE ELECTRICAL DIAGRAM T PROJECT LOCATION ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF '_ ' + E-2 • PV SYSTEM SAFETY LABELING DIAGRAM.- ' VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE I AND ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE FAS . f T f' _PSR JECT DESCRIPTION L - COVER PAGE BEEN RESTORED P8R NEC 690.81 'py' 7. ALL SPECIFIED WIRING IS BASED ON COPPER SPECIFICATIONS. - i !�% -•.i' *� )�• •-^ BRADLEY REDBURN PROPERTY PHOTOVOLTAIC PROJECT WILL ENCOMPASS ' 8. - THE CONTRACTOR 8HALL VERIFY ALL SPECIFICATIONS BEFORE ) .i 7 - 4Y�*aw . THE INSTALLATION OF O PHOTOVOLTAIC SYSTEM CONSISTING OF (1) 3.42 S • - ORDERING OR ACF R tHATING ANY MATERIRESPONSIBLE LL. - .� , - (DC) ARRAY SERVING THE 1 -PHASE METER. THE ARRAY 13 CONSIDERED A 9. THE CONTRACTOR ITS A BE RESPONSIBLE FOR MAINTAINING CURRENT _kW nl�-Wllmm ,Y ', + UTILITY INTERACTIVE SYSTEM WHICH WILL INTERCONNECT WITH THE PROJECT DOCUMENTS AND SPECIFICATIONS ON SITE DURING �;.�"•- r- k `+ _ EXISTING ELECTRIC DISTRIBUTION SYSTEM. THE PHOTOVOLTAIC SYSTEM • CONSTRUCTION. - + 1 /l� CONSISTS OF 12 PH r4'Oe ibex 10. SEE PROVIDED SPEC -SHEETS FOR ADDITIONAL EQUIPMENT N�T f - - r/ `• ( ) PHOTOVOLTAIC MODULES AND (12) UTILITY INTERACTIVE SPECIFICATIONS. - ,+ ���111"'JJJ MICRO4NVERTERS, - �• .►-• 11. ALL ELECTRICAL EQUIPMENT SHALL BE PROTECTED FROM ANY PHYSICAL ! ' �"•� f DAMAGE. r • , s • _ - .. f 12. THE INSTALLATION CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS r f� O I •f - i . -._ NORTH STATE SOLAR ENERGY . AND SHALL COORDINATE ALL INSPECTIONS, TESTING, COMMISSIONING '. f s - ' • a, P.O. BOX 899 ' - I AND ACCEPTANCE WITH THE CLIENT, UTILITY, AND MUNICIPAL r } Y- . t - . ' J PHONE: 5FOREST 3 0.3442.730496942 INSPECTORS AS NEEDED, iJ'- TIT F + _ FAX:530.725.4383 13. THE ELECTRICAL CONTRACTOR SHALL L UTIFY LITY E EXACT LOCATIONS OF - - _ ' • • • r W W W.NORTHSTATESOLARENERGY.COM .t. L SERVICE POINTS AND COMPLY WITH ALL UTIAL I STAL REQUIREMENTS. - • ..• LICENSE 1t. B813508 14. DRAWINGS ARE DIAGRAMMATIC ONLY, ACTUAL INSTALLATION OF ALL 4 � - , • EQUIPMENT SHALL BE THE DECISION OF INSTALLATION CONTRACTOR. - PROJECT LOCATION • 15. IF DISTANCES OF CONDUCTOR RUNS ARE DIFFERENT THAN SHOWN, THE • + - - CONTRACTOR SHALL NOTIFY THE SYSTEM DESIGNER TO VALIDATE THE - WIRE SIZE. FINAL DRAWINGS WILL BE REVISED AS APPROPRIATE - 16. THE INSTALLATION CONTRACTOR IS RESPONSIBLE FOR NOTIFICATION PARCEL DETAIL WITH SETBACKS AND COORDINATION WITH ALL PROPERTY OWNERS, UTILITIES AND SCALE' 1/16"= 1'-O"' - - y - SOLAR PV DESIGNER: APPROPRIATE DIG -ALERT UNDERGROUND MAP40NG AGENCIES. THE • ' _ +• 3 •' i - ' - ' - ' CONTRACTOR SHALL ALWAYS USE EXTREME CAUTION WHEN TRENCHING J ro- --•r _ - .-. A r __ _ µ rt,� _ . - .�• ..,� _. _ - RENEWABLE ,. • FOR INSTALLATION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE r•. " - _ - "' " ' - �' - - - *' — "— """ _ — r RENE10945 ESTATE LANE PROPER AND APPROVEDWABLE DESIGN SOLUTIONS REPAIR OF ANY AND ALL DAMAGES CAUSED - r . DURING THE INSTALLATION. _ - r - • ., • . _ , f •_ _ - , �. SUITE E-109 17. INSTALLATION SHALL BE IN ACCORDANCE WITH 2016 CALIFORNIA - - ' BUILDING STAND , DALLAS, 1479236 ARb9 1 W W W.RENEWABLEDESIGNSOLUTIONS.COM 17.1. 2018 STANDRN _ �� PHONE: 214.584,8535 IA BUILDING CODE 3 11 ;� NASCEP P. 092411-88 17.2. 2016 CALIFORNIA ELECTRICAL CODE - ; �i - w ♦ - 17.3. 2016 CALIFORNIA MECHANICAL CODE 17.4. 2016 CALIFORNIA PLUMBING CODE 17.5. 2018 CALIFORNIA ENERGY CODE 17.6. 2018 CALIFORNIA FIRE CODE - - 17.7. 2016 GREEN BUILDING CODE 108.50' ABBREVIATIONS: - r i VMP: MAXIMUM POWER VOLTAGE - • N T. IMP: MAXIMUM POWER CURRENT n - t- i . VOC: OPEN CIRCUIT VOLTAGE - .. 0p ❑ O r Lo ISC: SHORT CIRCUIT CURRENT .. d - - A' AMPERES - - - { s 0�0 V: - VOLTS P:POLE CU: - COPPER - NEC: NATIONAL RLECTRIC CODE - OC:' OFF CENTER - FIR: ROOF RAFTER ' PV:PHOTOVOLTAIC AHJ: Y AUTHORITY HAVING JURISDICTION - _ f - • - - • - DC: DIRECT CURRENT AC: ALTERNATING CURRENT ,+ • . - • . • - - t KW: KILO -WATTS W: WATTS: `J•.1'"` y S7C: STANDARD TESTING CONDITIONS • ,. r ` • _ K - ' .. ' ^ _ r _ - .. . s • - PTC: ; PV USA TESTING CONDITIONS - • ' - • a t AWG: - AMERICAN WIRE GAUGE • - i - ~ • - - - _ f j y "J- , DESIGNED13r, M. LABARBA „ . GEC: ' OROUNOINO ELECTRODE CONDUCTOR ' i - - i•? 'MIN: r - MINIMUM - ', . - ` �- - - , , •`�', • ♦ DATE - .12/05/2017 ' ' . 0 DIA: DIAMETER • - ' • w UL UNDERWRITER'S LABORATORY - - < - - _ - - l 08.50 • y + r + + , REVISED' _ .. RACEWAY ABBREVIATIONS: N w 1.'• N!A i 2. - .- EMT: ELECTRICAL METALLIC TUBING -. ' - - - _. - - - ` ENT: ELECTRICAL NON-METALIC TUBING. ' - 1 - 1 • _ _ 1 3. C FMC:- FLEXIBLE METALLIC CONDUIT FMT: FLEXIBLE METALLIC TUBING - ' t r - . - r • ` j01°T pr1 . f' S. r r 'IMC: INTERMEDIATE METAL CONDUIT _ - -• y � _ W � � r . LFMC: LIQUID TIGhT FLEXIBLE METALLIC SCALE NIA C CONDUIT' 4 - 4 - - (27p) . _ LFNC: • - LIQUID TIGHT(or) FLEXIBLE NON-METALLIC CONDUIT' • - - - ' a - - 'i • tars nvI RMC: RIGID METAL CONDUIT - RNC: RIGID NON-METALLIC CONDUIT '' _ - s4,• s r . r �• •,' r .. ... « � • � (180•) ' • PHOTOVOLTAIC PROJECT INFORMATION: • - 3.42 kW(DC)-3.00 kW (AC) ` • PV UTILITY INTERACTIVE SYSTEM BRADLEY REDBURN RESIDENCE 134512TH STREET OROVILLE, CA 95985 - - AHJ• BUTTE COUNTY • PV SYSTEM EQUIPMENT WALL (PLAN VIEW) UTILITY: PG&E • PROJECT NUMBER: EQUIPMENT WALL (ADJACENT TO UTILITY METER) ARRAY 4523-113AT STRUCTURE - ( ) PROTECT SHEET: M _______ — 7r SHEET TIRE: SITE PLAN A B CD A I (EXISTING) ALL -IN -ONE UTILITY METER AND 100A MAIN SERVICE PANEL (POINT OF INTER -CONNECTION VIA DEDICATED CIRCUIT BREAKER) B (NEW) PV SYSTEM DEDICATED 30A, 240V, 1t AC DISCONNECT SWITCH (VISIBLE, LOCKABLE,, LABELED) (ADJACENT TO MAIN SERVICE) C EMT CONDUIT RUN (NEW) ; (RUN ACROSS ROOF, 3.5" MIN. ABOVE GRADE), D (NEW) PV SYSTEM JUNCTION BOX (NEMA 3R, UL 1741) (AT ARRAY -UNDER MODULE) (530)'342'73n4 NORTH STATE SOLAR ENERGY ' P.O. BOX 899 FOREST RANCH, CA 95942 PHONE: 530.342.7304 FAX'530.725.4383 WWW.NORTHSTATESOLARENERGY.COM LICENSE #:13813508 - Lg�pj - SOLA.? PV DE9IGNE,4•'. RENEWABLE eFRMN AN IT STRUCTURAL DETAIL SCALE: 3/16"= V-0" - HARDWARE DETAIL PHOTOVOLTAIC PROJECT INFORMATION SCALE: N/A 3.42 kW (DC)-3.00 kW (AC) PV UTILITY INTERACTIVE SYSTEM END /MID -CLAMP . BRADLEY REDBURN RESIDENCE ' 1345 12TH STREET " - - OROVILLE, CA 85985 - - AHJ: BUTTE COUNTY 2'-0" - UTILITY: POSE ' 5'-1 1 J, , " - . - PROJELNU_WSF • IRONRIDGE XR100 RAIL 4523-113 r lFLASH FOOT 2 MOUNT PROJECT SNEET: - L-FOOT FLASHING - L-2 I I (ADJUSTABLE) SNETTTLF• ❑ O STRUCTURALLAYOUT WITH j MECHANICALDETAIL T T T co Firm fft 9= • 16'-9" NORTH STATE SOLAR ENERGY F P.O. BOX 899 HARDWARE DETAIL FOREST RANCH, CA 95942 - ` SCALE: N/A PHONE: 530.342.7304 FAX: S0•M5• 363 WWW.NORTHSTATESOLARENERGY.C.OM O I I T LICENSE #- 6813508 i rl 13'-6" 2"X4" SUPPORT S.S. FLANGE NUT MID CLAMP S.S. FLANGE NUT PURLIN END CLAMP S.S. ' HEX BOLT soLAR PV DESIGNER: 2n X 4" WOOD . RENEWABLE DESIGN SOLUTIONS — - - RAFTER ) 10945 ESTATE LANE SUITE E-108 - LOCATED 24" O.C. MODULE MODULE MODULE 75238 DALLAS rx W4.S PHONE: 214.584.9535 WW.RENEWABLEDESIGNSOLLMONS.COM i N NABCEP p: 092411.88 N IRONRIDGE SOLARWORLD ATTACHMENT POINT EXTERIOR IRON RIDGE XR100 RAIL SW285 MONO TO STRUCTURAL MEMBER LOAD XR100 RAIL IRON RIDGE 285W MODULES (22 TOTAL) • BEARING XR100 RAIL (6'-0" O.C. MAX) WALL ELEVATION DETAIL ' ' SCALE: 1" = T-0" SOLAR MODULE- MECHANIC DATA SOLARWORLD SW285 MONO2BSW MODULE ' MODULE SPECIFICATIONS: ODULE SQUAFOOTAGE: 65.95'x 39.40" x 1.22°, 39.5 LBS MRE ' _ f�DULE WEIGHT PER SQDAR€ FOOT: 18.05 SOFT2.20 LBS SOLAR ARRAY: ECHANICAL DATA MODULE DETAIL . . M DULES: (12)MODULES ARRAY_ L_ pq0. . • w^QQv��W 65� SCALE: 1/2"=1'-0" " ARRAY So.. 474.00 LBS So.. 216.60 SOFT ' 1r` MDDu� DEAD LOAD EDP 567.00 DFADLOAD Zg`'VJ (W) 39.40" ��%� ARRAY DEAD 5 n BSS ILL MENNOT Op0 gWZBS M .. LOAD WEXCEEDCKING . ARRAY pEAp LppD: Oa`O 4 2.62 LB/SQ.FT 01 50 CONNECTOR TYPE-• 5/16"X 3.5° S.S. LAG SCREW - FLASHING (2.5' MIN. EMBEDMENT) ATTACHMENT POINTS: (22) ATTACHMENTS IRONRIDGE XR100 RAIL SYSTEM NOTES: ROOF SHEATHING (SINGLE LAYER) 1. VERIFY ALL MEASUREMENTS AND CHALK INSTALLATION AREA PRIOR TO DRILLING PILOT HOLES �y IRON RIDGEFLASHFOOTMOUNT - 2'X4°WOOD RAFTER _ - 2• DRILL PILOT HOLE PRIOR TO SECURING LAG BOLT (SEE INSTALLATION INSTRUCTIONS) DESIGNED BY: M. LABARBA 5/16' X 3S' S.S. LAG SCREW (24.O.C.) 2.5' MIN. EMBEDMENT-SEAL PENETRATION (4:12 PITCH) L6 CO 3. LAG BOLT SHALL BE LOCATED IN THE MIDDLE THIRD OF THE STRUCTURAL MEMBER 4. SECURE LAG BOLTS FLUSH TO STRUCTURAL MEMBERS DATE: 12/05/2017 WITH SILICON BASED ROOF SEALANT - FOLLOWING MANUFACTURE'S SPECIFIED TORQUE STRENGTHS. END/ MID-0LAMP SEAL CONNECTION POINTS WITH ROOF GRADE GEOCEL SEALANT, 8• FOLLOW MANUFACTURE'll •� NS REGARDING RAIL SPLICE POINTS FOR THERMAL EXPANSION CONSIDERATION. =4. ASPHALT SHINGLE ROOF ' . - - SCALE: N/A q -., - _ r •.. • ,- r• y ` •' ' . _ - - L 4• �' • - ' • 1 . - PHOTOVOLTAIC PROJECT INFORMATION: ` 3A2 kW (DC) -3.00 kW (AC) • -4 DC E.G.C. LAY -IN -LUG. •r vv uTILTfY INTERACTIVE SYSTEM 4 SOLAR MODULE: ELECTRICAL DATA UL 2703 SOLARWORLD SW285 MONO 285W MODULE SPECIFICATIONS AT STC ' MAXIMUM'POWER VOLTAGE (Vmp) 31.30V , MAXIMUM POWER CURRENT (Imp) 9.20A _• OPEN CIRCUIT VOLTAGE (Voc) 39.70V - SHORT CIRCUIT CURRENT (isc) 9.84A ' SERIES FUSE RATING 16A t Voc TEMPERATURE COEFFICIENT: , _ -.31%/C4 4 WEIGHT 39.7 LBS ' DIMENSION. ' 65.95" x 39.40" x 1.30" LISTED AS COMPATIBLE W/ ENPHASE M250 INVERTER STC = 25°C, 1000W/M2, .1.5 AIR MASS UTILITY: PG&E SOLAR INVERTER: ELECTRICAL DATA r SIZE: 250 WATTS (AC) MFR: CHILICON POWER MODEL: } CP -250E-60-72-208/240 (240V) CERTIFICATION: UL 1741, IEEE 1547. MAX INPUT VOLTAGE: 60VDC I INPUT VOLTAGE RANGE: 22-38.5 VAC MAX INPUT CURRENT (Isc) 21.0 ADC MAX OUTPUT CURRENT,(Imax). 1.04A AC @ 240V MAX OUTPUT CURRENT PRO. 20A AC @ 240V MAX CONTINUOUS POWER 285W CEC WEIGHTED EFFICIENCY '96.6% -- •' - -+ ' + WEIGHT 3.40 LB DIMENSION: 12" x 8" x 1.8" MAX RECOMMENDED INPUT 345 WATT MODULE Voc MAXIMUM CALCULATION: ` v i✓ d� "i SHEET TITLE: , 39.70 (1 + (-3°C - 25°C)( -.31%/C°)= Voc MAX f. 39.70 (1.09) = 43.27 AT -3°C (ASHRAE) ) �. , MODULE STRING DETAIL TEMPERATURE MINIMUM: 26.6°F / -3°C TEMPERATURE MAXIMUM: 109.4°F / 43°C • ' 'ASHRAE , "� ' ' - UL 2703 (1), PER RAIL '- + NEUTRAL WHITE tiY GROUNDING MID -CLAMP •� BRADLEY REDBURN RESIDENCE 134512TH STREET . - ' • •' - ; •, �, • .. - - + OROVILLE, CA 85985 - I • •{"' _ , - ; _ AHJ: BUTTE COUNTY, " UTILITY: PG&E •- r . -_ - J• _ •. .� y- y. - r .. r ,,� ' ' - .-' PROJECT NUMBER: - .• GENERAL N07E6: - • ,- j_ 4523-1.13 _. , PV SYSTEM: PV BRANCH CIRCUITS ' . • • "- • _ PROJECT SHEET: 3.42 kW (DC) r t e Y� -, E-1 3.00 kW (AC) 4 _ y� (12) SOLARWORLD SW285 MONO BLACK 285W MODULES . ' v i✓ d� "i SHEET TITLE: , (12) CHILICON POWER CP -250E-60-72-208/240 (240V) MICRO -INVERTERS , , MODULE STRING DETAIL (SEE 1 -LINE DIAGRAM FOR STRING DESIGN)- .' " AND T ELECTRICAL 4 S. 6 MINIMUM 80• MOISTURE RATED INSULATION WIRE IS REQUIRED ON ALL OUTDOOR V jRING ` • ` ' ti, '� `- SPECIFICATIONS S CONDUCTORS ARE TO BE COPPER UNLESS OTHERWISE NOTED - ALL EQUIPMENT SHALL BE UL LISTED, NEMA 3R RATED, LABELED AND INSTALLED IN ACCORDANCE WITH MANUFACTURES INSTRUCTIONS. .. } - . s - • • , - .- _ • ' - , " . B. 8. W EQUIPMENT GROUNDING CONDUCTOR SHALL BE INSTALLED IN ACCORDANCE WITH CEC 690.43, CEC BBOAS CEC 890.48. EQUIPMENT GROUNDING CONDUCTOR TO BE CONTINUOUS PER CEC 890AS. ♦ . DC E.G.C. TO EXISTING GROUND SYSTEM '" 10. GROUNDING ELECTRODE CONDUCTOR SHALL BE INSTALLED IN ACCORDANCE WITH CEC 99OA7 - • - r - ._ r �. • ', - ". 11. It GROUNDING ELECTRODE CONDUCTOR SMALL 8E CONTINUOUS PER LEC 250.80 (C} + ALL GROUNDING CONNECTIONS • (1) #6 AWG BARE CU GROUND R _ _ 13. SHALL BE MADE WITH UL LISTED CONNECTORS GROUNDING CONNECTION TO MODULES SHALL BE SECURELY FASTENED WITH UL LISTED STAINLESS STEEL LAY4M LUGS OR EOUNALENT UL MEANS - . +f i ' I WHERE GROUNDING CONNECTIONS ARE MADE TO GROUNDING ELECTRODE(S). ONLY CAD -WELD EXOTHERMIC CONNECTIONS OR IRREVERSIBLE CRIMPS SHALL BE USED. (GND TO BE'CONTINUOUS AND IN : 1 w - l r EwcbqCft' - .• ¢ 13. FOR FLAT ARRAY INSTALLATIONS. PROVIDE THE NORTH EDGE OF ARRAYS 114' HIGHER TO DISPLACE WATER. - . S 1 , •• ' •'I y y , i I '„ r ACCORDANCE WITH NEC 250.64 (C) NOMODIFICATIONS TORACKING SMALL EQUIPMENT MAINTAIN MANNERRMIZESTALLATON PRACTICES. - - WHEN POSSIBLE, INSTALL WIRING AND BOB0EQUIPMENT IN A MANNER THAT MINIMIZES SUNLIGHT EXPOSURE F.U.0. l m ` 1' - y, , .. L - ,. • - - - ' ' " . •' 'w• ` 16. ALL CONDUIT SYSTEMS EXPOSED TO TEMPERATURE DIFFERENTIALS SHALL BE INSTALLED WITH EXPANSION FIRINGS AND BONDING JUMPERS IN ACCORDANCE WITH CEC 300.7(8) _ R '' • • I , IB. 20. BFORECTIONAL UTILITY METER TO BE INSTALLED IF REQUIRED. VERIFY METER SOCKET AND OTHER SPECIFICATIONS FOR COMPLIANCE WITH UTILITY. ALL INVERTERS SHALL BE UL 1741 AND IEEE 1547 COMPLIANT AND INSPECTED BY LOCAL URU7Y PRIOR TO COMMISSIONING AND OPERATION, - _ _ 1 '• - ' - •' + _ DESIGNED BY: : M. LABARBA A INVERTERS SHALL BE PROTECTED FROM DIRECT SUNLIGHT EXPOSURE. •• ` I �.. - } 240 VAC .� � _ ' 22 CIRCUIT BREAKER TO BE SUITABLE PER CEC 68084 (Bx5) • - . ' - ': f Hill GATE' 12l 0512017 - ' MAXIMUM SYSTEM VOLTAGE TO BE DEFINED PER CEC 890.7 AND SHALL NOT EXCEED Wall. - _ ME UTILITYAC DISCONNECT SHALL BE LOCATED NO FURTHER THAN 5 FEET FROM THE NET METER CHILICO ACq ' ! `• NORTH STATE SOLAR ENERGY P.o.BOX Be9 _ i 25. • THE UTILITY AC DISCONNECT SHALL BE LOCATED ADJACENT TO POINT OF INTERCONNECTION. - J _ • " a _ • {� �- - REVISED: ,. . NIA ENGAGE CABLE • RE -TIGHTEN CURRENT -CARRYING CONNECTIONS. ENCLOSURE SUPPORT FRAMING AND PANELS TO MANUFACTURER89 RECOMMENDATIONS. - - FOREST RANCH, CA 85942 • _ ' , �' - - i) if , . 4 ` ' 27, TOTAL CURRENT HARMONICS SMALL BE LESS THAN 3%AT ONERTER AC TERMINAL ' .`. r , - I I Y >. • AND BARE #6 AWG • PHONE: 530.342.7304 FAX 530.725.4383 • w - - " ' ' • • tl" I .E 30. WWW.NORTHSTATESOLARENERGY.COM • I ; '4 LICENSE A 8813508 3. -- -- -- . - '. - 31. 32. WHEN A CIRCUIT BREAKER IS THE METHOD OF INTERCONNECTION, ORCUNT BREAKER SHALL NOT READ'UNE AND LOAD'. - - ' FIELD VERIFY ALL SPECIFICATIONS PRIOR TO INSTALLATION. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE DESIGN ENGINEER OF ANY DISCREPANCIES BETWEEN THE __ - - ., - JUNCTION BOX NEMA 3R, -UL 1741 4•' 5 - PROVIDED DOCUMENT AND FIELD SPECIFICATIONS FIELD VERIFY , r 1 ' ' 1 • _ • ( (AT ARRAY) . 33. 34. EXACT REQUIREMENTS WITH UTILITY AND CLIENT, INCLUDING AVAILABLE FAULT CURRENT, PRIOR TO ORDERING EQUIPMENT. THE INSTALLATION CONTRACTOR IS RESPONSIBLE FOR NOTIFICATION AND COORDINATION WITH ALL PROPERTY OWNERS. UWTIES AND APPROPRIATE OIG -ALERT AGENCIES. THE + • R - _ - • - ' a (r BSE: N/A ' CONTRACTOR SHALL ALWAYS USE EXTREME CANTON WHEN TRENCHING FOR INSTALLATION THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER AND APPROVED REPAIR OF ANY N PV BRANCH CIRCUIT'^ soLARPvoesIGNER N• + TRANS TO CONDUIT RENEWABLE DESIGN SOLUTIONS MARKING ON INTERIOR AND EXTERIOR (DC) CONDUIT, ENCLOSURES, RACEWAYS CABLE ASSEMBLIES, JUNCTION BOXES, COMBINER BOXES. AND DISCONNECTS SHALL BE IN ACCORDANCE - + .� ! ' , •w • " , ,. ' (y _ • (SEE SHEET E-2 ) 10945 ESTATE LANE SURE E•105 iC - ., II S ,. r y + DALLAS, Tx 75238 • - • .. , • - - I TIN • `l_ t PHONE: 214.584.9538 L+ _ ♦ 1 - - II _ LOCATIOF THE PV SOURCE CIRCUIT OCPD IB ACCESSIBLE AT THE GROUND MOUNTED ARRAY IN ACCORDANCE WITH CEC 240. - .. 1` 1 4 .- . - WWW.RENEWABLEDESIGNSOLUTIONS.COM • • . - I II 0 39.. ALL PVON AC DISCONNECTS ARE READILY ACCESSIBLE SEE AC DISCONNECT DESCRIPTION. - . N • , .. - , NASCEPP..092411�88 •' - - L--- - �_• . • CHILICON ENGAGE CABLE CONDUCTOR COLOR GUIDE CHILICON ENGAGE CABLE 240 VAC 240 VAC, 1 I$I ' (2) #12 THWN-2 AWG CU y - ' 0.1 '" BLACK r (1) #12 THWN-2 AWG CU (NEUTRAL) L2 RED (1) #12 THWN-2 AWG CU E.G.C. GROUND - 4 (GND TO BE CONTINUOUS) - - i NEUTRAL WHITE - AC E.G.C. GREEN _ •- r . -_ - J• _ •. .� y- y. - r .. r ,,� ' ' - .-' ? - .• GENERAL N07E6: - • ,- j_ 1. EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH 2016 CEC ARTICLE 880. MUNICIPAL REQUIREMENTS. AND UTILITY REQUIREMENTS • "- �- 2. PV CONSTRUCTION DOCUMENTS ARE NOT TO BE USED UNTIL APPROVED BY THE AUTHORITY HAVING JURISDICTION AND THE SERVING UTILITY. i _ •r' 3. _ WORKING CLEARANCES MOUND THE EXISTING AND NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IS ACCORDANCE WITH CEC 11028 , 1 _ .' 4. ' ALL CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER CEC 300.8 (CXIX 310.8 (D). - �.• .. , • - - - . ...' 4 S. 6 MINIMUM 80• MOISTURE RATED INSULATION WIRE IS REQUIRED ON ALL OUTDOOR V jRING ` • ` ' ti, '� `- L 7. S CONDUCTORS ARE TO BE COPPER UNLESS OTHERWISE NOTED - ALL EQUIPMENT SHALL BE UL LISTED, NEMA 3R RATED, LABELED AND INSTALLED IN ACCORDANCE WITH MANUFACTURES INSTRUCTIONS. .. } - . s - • • , - .- _ • ' - , " . B. 8. W EQUIPMENT GROUNDING CONDUCTOR SHALL BE INSTALLED IN ACCORDANCE WITH CEC 690.43, CEC BBOAS CEC 890.48. EQUIPMENT GROUNDING CONDUCTOR TO BE CONTINUOUS PER CEC 890AS. ♦ '" 10. GROUNDING ELECTRODE CONDUCTOR SHALL BE INSTALLED IN ACCORDANCE WITH CEC 99OA7 - • - r - ._ r �. • ', - ". 11. It GROUNDING ELECTRODE CONDUCTOR SMALL 8E CONTINUOUS PER LEC 250.80 (C} + ALL GROUNDING CONNECTIONS • " - - • - R _ _ 13. SHALL BE MADE WITH UL LISTED CONNECTORS GROUNDING CONNECTION TO MODULES SHALL BE SECURELY FASTENED WITH UL LISTED STAINLESS STEEL LAY4M LUGS OR EOUNALENT UL MEANS - ' 14. WHERE GROUNDING CONNECTIONS ARE MADE TO GROUNDING ELECTRODE(S). ONLY CAD -WELD EXOTHERMIC CONNECTIONS OR IRREVERSIBLE CRIMPS SHALL BE USED. 1 w - l - r - .• ¢ 13. FOR FLAT ARRAY INSTALLATIONS. PROVIDE THE NORTH EDGE OF ARRAYS 114' HIGHER TO DISPLACE WATER. - . S 1 , •• ' •'I y y , :.. '„ r 18. 17. NOMODIFICATIONS TORACKING SMALL EQUIPMENT MAINTAIN MANNERRMIZESTALLATON PRACTICES. - - WHEN POSSIBLE, INSTALL WIRING AND BOB0EQUIPMENT IN A MANNER THAT MINIMIZES SUNLIGHT EXPOSURE "` L' ` 1' - y, , .. L - ,. • - - - ' ' " . •' 'w• ` 16. ALL CONDUIT SYSTEMS EXPOSED TO TEMPERATURE DIFFERENTIALS SHALL BE INSTALLED WITH EXPANSION FIRINGS AND BONDING JUMPERS IN ACCORDANCE WITH CEC 300.7(8) _ R '' r IB. 20. BFORECTIONAL UTILITY METER TO BE INSTALLED IF REQUIRED. VERIFY METER SOCKET AND OTHER SPECIFICATIONS FOR COMPLIANCE WITH UTILITY. ALL INVERTERS SHALL BE UL 1741 AND IEEE 1547 COMPLIANT AND INSPECTED BY LOCAL URU7Y PRIOR TO COMMISSIONING AND OPERATION, - _ _ 1 '• - ' - •' + _ DESIGNED BY: : M. LABARBA 21. INVERTERS SHALL BE PROTECTED FROM DIRECT SUNLIGHT EXPOSURE. •• ` '- �.. - } • _ _ ' 22 CIRCUIT BREAKER TO BE SUITABLE PER CEC 68084 (Bx5) • - . ' - ': f - - r : r• GATE' 12l 0512017 - 23. 24. MAXIMUM SYSTEM VOLTAGE TO BE DEFINED PER CEC 890.7 AND SHALL NOT EXCEED Wall. - _ ME UTILITYAC DISCONNECT SHALL BE LOCATED NO FURTHER THAN 5 FEET FROM THE NET METER . '+ . i - _ i 25. • THE UTILITY AC DISCONNECT SHALL BE LOCATED ADJACENT TO POINT OF INTERCONNECTION. - J _ • " a _ • {� �- - REVISED: ,. . NIA 26. • RE -TIGHTEN CURRENT -CARRYING CONNECTIONS. ENCLOSURE SUPPORT FRAMING AND PANELS TO MANUFACTURER89 RECOMMENDATIONS. - - • • _ ' , �' - - i) if , . 4 ` ' 27, TOTAL CURRENT HARMONICS SMALL BE LESS THAN 3%AT ONERTER AC TERMINAL ' .`. r , - ^ - { 4 Y >. • 2. NIA. 20. 28. ARRAY LAYOUT SHALL BE CONSISTENT WITH THE ORDERING (AND LABELING) OF SOURCE CIRCUITS IN THE ARRAY COMBINER BOXES ALL BURIED RACEWAYS SHALL BE BURIED 1S' FROM TOP OF CONDUIT/CDNDUCTOR - w - - " ' ' • • tl" - - '- 30. TO GRADE ,. .. ALL WIRE SLANG SHALL BE IN • • e ; '4 3. ACCORDANCE WITH CEC 110.11 BACITED "" . .F • '. 31. 32. WHEN A CIRCUIT BREAKER IS THE METHOD OF INTERCONNECTION, ORCUNT BREAKER SHALL NOT READ'UNE AND LOAD'. - - ' FIELD VERIFY ALL SPECIFICATIONS PRIOR TO INSTALLATION. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE DESIGN ENGINEER OF ANY DISCREPANCIES BETWEEN THE - - ., - - 4•' 5 - PROVIDED DOCUMENT AND FIELD SPECIFICATIONS FIELD VERIFY , r 1 ' ' 1 • _ • , 33. 34. EXACT REQUIREMENTS WITH UTILITY AND CLIENT, INCLUDING AVAILABLE FAULT CURRENT, PRIOR TO ORDERING EQUIPMENT. THE INSTALLATION CONTRACTOR IS RESPONSIBLE FOR NOTIFICATION AND COORDINATION WITH ALL PROPERTY OWNERS. UWTIES AND APPROPRIATE OIG -ALERT AGENCIES. THE • R - _ - • - ' a (r BSE: N/A ' CONTRACTOR SHALL ALWAYS USE EXTREME CANTON WHEN TRENCHING FOR INSTALLATION THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER AND APPROVED REPAIR OF ANY N AND ALL DAMAGES CAUSED DURING THE OLSTALLATIOH N• + 35. MARKING ON INTERIOR AND EXTERIOR (DC) CONDUIT, ENCLOSURES, RACEWAYS CABLE ASSEMBLIES, JUNCTION BOXES, COMBINER BOXES. AND DISCONNECTS SHALL BE IN ACCORDANCE - + .� ! ' , •w • " , ,. ' (y _ • •' - - - WITH SECYION 808.11.1 OF THE 2013 CFC - ♦ S ,. r .. '} 7. 38. 37. PV ARMY CONDUCTOR CABLES COMPLY WITH CEC 880.31 (B) AND ARE IDENTIFIED AS USE 2OR PV WARE GROUND FAULT PROTECTION IS INTEGRAL TO THE INVERTER AND COMPLIANT WITH CEC 880.5.705.32 • `l_ .� - . • - - • - 38. _ LOCATIOF THE PV SOURCE CIRCUIT OCPD IB ACCESSIBLE AT THE GROUND MOUNTED ARRAY IN ACCORDANCE WITH CEC 240. - .• '• •.. + • a_ _ 1 �.„ , + - �. 39.. ALL PVON AC DISCONNECTS ARE READILY ACCESSIBLE SEE AC DISCONNECT DESCRIPTION. - . N • -T •' - - "4 •d_, ,r VOLTAGE DROP CALCULATION -V drop% = VOLTAGE DROP (volts) (%) 1 op= OPERATING CURRENT (amps) L a LENGTH OF CIRCUIT (ft) . < V op = OPERATING VOLTAGE (volts) ` Iopx2XL Q -. 1000 ft/kft Xkft; . x 100 ' V op % (1)18 BRANCH CIRCUIT (PORTRAIT) V -DROP PER CHILICON V -DROP GUIDE' --.80% J -BOX TO PV SUB -SYSTEM LOAD _CENTER, , 12.50AX2X201 1000 ft/kft X 1.2,.''' V drop% = 'x 100.=,.25%,-. • 240V PV SUBSYSTEM LOAD CENTER TO INTERCONNECTION ' 12.50Ax2x10' x1.2 1000 f lkft V drop% = x 100 240V PV SYSTEM WORST CASE V -DROP (LONGEST SYSTEM RUNS)' ` ( ) -1 XISTING) - , , I I AND BARE #6 AWG GRADE) + ,� UTILITY -' I n GENERAL -NOTES. "' • - •' . _ _ - - METER MAIN SER CE PANEL - . 1. EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH 2016 CEP ARTICLE 690, MUNICIPAL REQUIREMENTS, AND UTILITY REQUIREMENTS r " " .- ,r+ . ' ^1,•, • ` ' ` - PHOTOVOLTAIC PROJECT INFORMATION: A 2. PV CONSTRUCTION DOCUMENTS ARE NOT TO BE USED UNTIL APPROVED BY THE AUTHORITY HAVING JURISDICTION AND THE SERVING UTILITY. $ • - _ - � � - ' •- 4 • ' . ' i i 3.42 kW (DC) - 3.00 kW (AC) ' 3.. WORKING CLEARANCES AROUND THE EXISTING AND NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IS ACCORDANCE WITH CEC 110.28 r 4. ALL CONDUCTORS EXPOSED TO SUNLIGHT ri 4 ' * _ -' ' - 4 - ,! , L += '� „ PV UTILITY INTERACTIVE SYSTEM • , , SHALL BE LISTED AS SUNLIGHT RESISTANT PER CFC 300.8 (CXU 310.8 (D). .- -• , f 1 s, _ • �r - 1 L •- ' S. MINIMUM 90• C MOISTURE RATED INSULATION WIRE IS REQUIRED ON ALL OUTDOOR WIRING. -, - - -6. CONDUCTORS ARE TO BE COPPER UNLESS OTHERWISE NOTED a, t . + ►•• . • F - - • j ' .. + BRADLEY REDBURN RESIDENCE r - _ - 7. ALL EQUIPMENT SHALL BE UL LISTED, NEMA 3R RATED, LABELED AND INSTALLED IN ACCORDANCE WITH MANUFACTURES INSTRUCTIONS. - t ' f r - - . - • 134512TH STREET O 45 i2TH, CA STREET ' .r ' 8. EQUIPMENT GROUNDING CONDUCTOR SHALL BE INSTALLED IN ACCORDANCE WITH CEC 880.43, CEC Sg0.45, CEC 690.48. y _ ' '� - • - ANO: BUTTE COUNTY « 4 I'. _ EQUIPMENT GROUNDING CONDUCTOR TO BE CONTINUOUS PER CEC OWAS, -3 ..r •' - , +r - - ; - - ; ', • ' - - UTILITY: PGCE +s (1) #8 AWG THWN-2 CU E.G.C. _ 10, GROUNDING ELECTRODE CONDUCTOR SHALL BE INSTALLED IN ACCORDANCE WITH CEC 690.47 v ► • _ } + * :4 _ . _, Z kl •�• _ „ , ' • - ^ 11. • GROUNDING ELECTRODE CONDUCTOR SHALL BE CONTINUOUS PER CEC 250.64 (C). '" - ' 12. CONNECTIONS '4' T ` ' - - - + { c �• , • } .3/4" EMT CONDUIT ALL GROUNDING SHALL BE MADE WITH UL LISTED CONNECTORS.•C v' _ d' -� ,'i1 ' a „•,. ' PROJECT NUMBER: • • ,w 13. GROUNDING CONNECTION TO MODULES SHALL BE SECURELY FASTENED WITH UL LISTED STAINLESS STEEL LAWN LUGS OR EQUIVALENT UL Y , _ t MEANS.' - 14. , WHERE GROUNDING CONNECTIONS ARE MADE TO GROUNDING ELECTRODE(S), ONLY CAD -WELD EXOTHERMIC CONNECTIONS OR IRREVERSIBLE - � - • _ * * r A- „ 4 .• s -;, - - . - ... - • 4523-113 ' •-, r• rL ti .CRIMPS SHALL BE USED. •, '. 1S. FOR FLAT ARRAY INSTALLATIONS, PROVIDE THE NORTH EDGE OF ARRAYS 1/4' HIGHER TO DISPLACE WATER - - ' $ A , ;1 y .., n - - '� r I, � a - - • ` PROJECT SHEET: y - • + • 18. , NO MODIFICATIONS TO RACKING SHALL BE PERMRTEO. MAINTAIN MANUFACTURES INSTALLATION PRACTICES, " 17. WHEN POSSIBLE, INSTALL WIRING - '' - +• • - _ ' r` '' ji - C �] _ ,- C -L « }" , • - AND SOS EQUIPMENT IN A MANNER THAT MINIMIZES SUNLIGHT EXPOSURE •' ^. - ' _ _ r _ 13. ALL CONDUIT SYSTEMS EXPOSED TO TEMPERATURE DIFFERENTIALS SHALL BE INSTALLED WITH EXPANSION FITTINGS AND BONDING JUMPERS W * 11 ' 3 r - � - SHEET TITTLE: ACCORDANCE NTHCEc300.7(B) 19. BIDIRECTIONAL UTILITY METER TO BE INSTALLED IF • , REQUIRED. VERIFY METER SOCKET AND OTHER SPECIFICATIONS FOR COMPLIANCE WITH ' . - • ' _ ' - 1, . , _ 1 -LINE ELECTRICAL. UTILITY. - ; 20: ALL INVERTERS SHALL BE UL 1741 AND IEEE 1547 COMPLIANT AND INSPECTED BY LOCAL UTILITY PRIOR TO COMMISSIONING AND OPERATION.. ".- r - • , ' r • f _ , . . - + " - -.•. - - -(-4 - ' ' •i1 ' N DIAGRAM • 21, INVERTERS SHALL BE PROTECTED FROM DIRECT SUNLIGHT EXPOSURE. - • .. , - - , • . , .. r - ` ;; 22. CIRCUIT BREAKER TO BE SUITABLE PER CEC 705.12 (Dp6) 1 23. "MAXIMUM SYSTEM VOLTAGE TO BE DEFINED PER CEC 89D.7 AND SHALL NOT EXCEED BOOV. - ., _ .. - , -.. "fit-• ' . ' ( L r _ ' _ - _ • '` " 24. • THE UTILITY AC DISCONNECT SHALL BE LOCATED NO FURTHER THAN 5 FEET FROM THE NET METER - - • • . •., ' '- ' 25.. THE UTILITY AC DISCONNECT SHALL BE LOCATED ADJACENT TO POINT OF INTERCONNECTION. .' 26. RE CURRRNT•CARRYING •.'L• , '- : � _ ., `• fff, M-1 14M .. .. . r -TIGHTEN CONNECTIONS, ENCLOSURE SUPPORT FRAMING AND PANELS TO MANUFACTURERS'S RECOMMENDATIONS., 27. TOTAL CURRENT HARMONICS SHALL BE LESS THAN 3%AT INVERTERAC TERMINAL '' - -, ' • •.,}(12)250 WATT UTILITY INTERACTIVE INVERTERS ' Emcwkft ^- . •.. _ 28. ARRAY LAYOUT SHALL BE CONSISTENT WITH THE ORDERING (AND LABELING) OF SOURCE CIRCUITS IN THE ARRAY COMBINER BOXES.' •' : ••` - , ._ VRI Ffto the Sun . 29. - ALL BURIED RACEWAYS SHALL BE BURIED 18' FROM TOP OF CONDUIT/CONDUCTOR TO GRADE 30., ALL SIZING SHALL _ '' •. J' CHILICON POWER CP-25OE-60-72-206/Z4O (Z4OV)- _ _ _.� i - NABACIRE IT IN BREAKER IS THEMTHCEC ODOFI 14 31. WHEN A BACKFED CIRCUIT BREAKER 19 THE METHOD OF INTERCONNECTION, CIRCUIT BREAKER SMALL NOT READ •LINE AND LOAD•. _ ' - - .•• _ • r CEC MODEL: CHILICON POWER CP -250E-60-72-208/240 (24OV) (SI1} , • � . • -- • 32.` FIELD VERIFY ALL SPECIFICATIONS PRIOR TO INSTALLATION. RISTHE RESPONSIBILITY OFTHE CONTRACTOR TONOTIFY THE DESIGN ENGINEER OF ANY DISCREPANCIES BETWEEN -• # �� + CEC-INVERTER EFFICIENCY: 96,6% • - + • NORTH STATEsoLARENERGY - - ,- - - THE PROVIDED DOCUMENT AND FIELD SPECIFICATIONS. 33. FIELD VERIFY EXACT REQUIREMENTS WITH uTilrrr AND CLIENT, INCLUDING AVAILABLE FAULT CURRENT, PRIOR TO ORDERING EQUIPMENT, THE INSTALLATION IS ' ; '• - . •. •. - , 240VAC, 1 60H2 - 1 } •,� 1' •� '°` P.O. BOX 889 ` FOREST RANCH. RANC2.7360 .34, CONTRACTOR RESPONSIBLE FOR NOTIFICATION AND COORDINATION WITH ALL PROPERTY OWNERS, UTILITIES, AND - _ APPROPRIATE DIG -ALERT AGENCIES. THE CONTRACTOR SHALL ALWAYS USE EXTREME CAUTION WHEN TRENCHING FOR INSTALLATION. THE r - _ ' ' ADJUSTABLE WATTAGE SETTING' ZSOW CONTINUOUS _ � I _ ' ` _ CA Bb942 PHONE: - CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER AND APPROVED REPAIR OF ANY AND All DAMAGES CAUSED DURING THE - a`� ' VOLTAGE AND PHASIONE SENSING NEUTRAL' _ t r --t _ d FAX: 630.726.4383 e MARKIINSTANG GNI. •35. MARKING ON INTERIOR AND EXTERIOR (DC) CONDOR, ENCLOSURES, RACEWAYS, CABLE ASSEMBLIES, JUNCTION BOXES, COMBINER BOXES, AND w . LISTED TO UL 1741 WWW.NORTH9TATE30LARENERGY.COM LICENSE P. 8813508 - - DISCONNECTS SHALL BE IN ACCORDANCE WITH SECTION 603.11.1 OF THE 2013 CFC 38. IN THE INSTANCE OF IMBALANCED SOURCE CIRCUITS, INSTALL THE SOURCE CIRCUITS STARTING ON ALTERNATING PHASES TD KEEP VOLTAGE _- �' ` - ' BO VDC MAX INPUT VOLTAGE • - _ .. q • ' BALANCED ACROSS THE ENTIRE SYSTEM. 37, PV ARRAY CONDUCTOR CABLES COMPLY WITH CEC 690.31 (8) AND ARE IDENTIFIED AS USE -2 OR PV WIRE. 38. FAULT PROTECTION , " INTEGRATED G.E.C. GROUND • • - t "- -! ' _ , - w +- L • GROUND IS INTEGRAL TO TME INVERTER AND COMPLIANT WITH CEC 890.5, 706,32 - 37, LOCATION OF THE PV PV SOURCE CIRCUIT: _ • •. " : • -_ SOURCE CIRCUIT IS ACCESSIBLE AT THE GROUND MOUNTED ARRAY 91 ACCORDANCE WITH CEC 240. _ _• T ;1 _ _ • �;.,� _; �y _ _ _ -� • - ACCESSIBLE. 38. ALL PV AC DISCONNECTS ARE READILY ACCESgIBLE, SEE AC DISCONNECT DESCRIPTION. --. - •^ -- - +'-' '•' - (1 Z) SOLARWORLD SW285 �^ `�` `!` �/^ 4 ~ x SOLAR PV DESIGNER: ' MONO 285W MODULES ' `t • ti „ .r VOC MAX = 43.27 VDC --- -_ -__ ® .. 1 .+ ; _ - RENEWABLE DESIGN SOLUTIONS 10945 ESTATE LANE - • - - ,, - + . . '-• _ ISc'= 9.71 AMPS - ® _ 3,. ) ,, V i SUITE E-105 DALLAS, TX 75238 ,. . £ _ r- - •• _ r••. -,• •` « P SUN RES WIRE ( -- PHONE: 214.564.9= SPC �t.�E9IGNSOLUTIONS.COM ,� - • F -y - - .. MODL ' INTEGRAL TOUE AND INVERTER * ♦�� JUNCTION BOX NEMA 3R, UL 1741 411-88 (AT ARRAY) 240 VAC (20 FT RUN) (2) #10 AWG THWN-2 CU ^ (1) #10 AWG THWN-2 CU (NEUTRAL) %(1) #8 AWG THWN-2 CU E.G.C. - (GND TO BE CONTINUOUS) _ 3/4" LFMC CONDUIT i ' ! r (RUN THROUGH ATTIC, 10" BELOW -' - - SHEATHING) 240 VAC AND / OR .. s ; . _ �.. � ENPHASE AC' 3/4" EMT CONDUIT } - , •• _ _ �� �.• �. . ENGAGE CABLE +" (RUN ACROSS ROOF 3.5" MIN: ABOVE ✓. w •; ' _ • /. _ - -• EXISTING r, �. • E '� - ... "4 •d_, ,r VOLTAGE DROP CALCULATION -V drop% = VOLTAGE DROP (volts) (%) 1 op= OPERATING CURRENT (amps) L a LENGTH OF CIRCUIT (ft) . < V op = OPERATING VOLTAGE (volts) ` Iopx2XL Q -. 1000 ft/kft Xkft; . x 100 ' V op % (1)18 BRANCH CIRCUIT (PORTRAIT) V -DROP PER CHILICON V -DROP GUIDE' --.80% J -BOX TO PV SUB -SYSTEM LOAD _CENTER, , 12.50AX2X201 1000 ft/kft X 1.2,.''' V drop% = 'x 100.=,.25%,-. • 240V PV SUBSYSTEM LOAD CENTER TO INTERCONNECTION ' 12.50Ax2x10' x1.2 1000 f lkft V drop% = x 100 240V PV SYSTEM WORST CASE V -DROP (LONGEST SYSTEM RUNS)' ` ( ) -1 XISTING) - , , I I AND BARE #6 AWG GRADE) + ,� UTILITY -' •100A, 1 240V n METER MAIN SER CE PANEL L .. + 240 VAC (10 FT RUN ) L L (EXISTING)' .r (2) #10 AWG THWN-2 CU,, ' �, %- '• r - • 100A ; (1) #10 AWG THWN-2 CU (NEUTRAL , _ MAIN (1) #8 AWG THWN-2 CU E.G.C. F BREAKER (GND TO BE CONTINUOUS) + • r A �F e-, 1P -15A - .3/4" EMT CONDUIT J L (RUN ALONG EQUIPMENT WALL) '� DesiGNEDsr:-M.LASARBA MONITORING ' •-, r• ' 2P -20A, �-LINE - LOAD S y DATES 12/05/2017 ,. . REVISED: NIA a , _ 1. N/A .20 3. T (NEW) DEDICATED PV SYSTEM ` UTILITY AC DISCONNECT SWITCH SCAUE: N/A ' I 2 -POLE, 30A, 240VAC, NEMA 311 ` ` (VISIBLE BLADE TYPE, LOCKABLE, T TO (EXISTING) ' ? LABELED, ACCESSIBLE 24/7) J 120/240 VAC, 1Q -SYSTEM GROUND: _'UTILITY GRID LIFER ' _ 'v r' . , - . .a. _ < « J 1• a T..,.... - a _ - _ - ''i , - - ~ v - ti. -