BUTTE COUNTY AREA
DEPARTMENT .OF DEVELOPMENT SERVICES
INSPECTION CARD MUST BE ON JOB SITE
24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspections is 3pm)
Development Services cannot guarantee inspections on the date requested
Office: 530.538.7601 Fax:530.538.7785 www.ButteCounty.net/dds
Permit No: B 18-0177 Issued:
APN: 047-430-054
Address: 40 FELICIDAD LN, CHICO
Owner: PETERS TINA M & DANNY L
Permit Type: SOLAR ROOF -RES
Description: ROOF MNT SOLAR (8.96 KW)
Flood Zone: . SRA Area:
SETBACKS for Zoning. AG. SRA. PW
Front: Centerline of Road:
Rear: SRA:
Street: AG:
Interior
Total Setback from Centerline of Road:
ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING
Inspection Type
IVR INSP DATE
Setbacks
131
Foundations / Footings
111
Pier/Column Footings
122
Eufer Ground
216
Masonry Grout
120
Setbacks
131
Do Not Pour Concrete Until Above are Signed
Pre -Slab
124
Gas Test Underground/floor
404
Gas Piping Underground/floor
403
Underfloor Framing
149
Underfloor Ducts
319
Shear Transfer
136
Under Floor Plumbing
412
Under Slab Plumbing
411
Blockin nde inin
612
Tiedown/Soft Set System
611
Do Not Install Floor Sheathing or Slab Until Above Signed
ShearwallB.W.P.-Interior
134
ShearwallB.W.P.-Exterior
135
Roof Nail/Drag Trusses
129
417
Manometer Test
Do Not Install Siding/Stucco or Roofing Until Above Signed
Rough Framing
153
Rough Plumbing
406
Rough Mechanical
316
Rough Electrical
208
4 -Way Rough Framing
128
Gas Piping House
403
Gas Test House
404
Shower Pan/Tub Test
408
Do Not Insulate Until Above Signed
t.
Permit Final
802
Electrical Final
803
Mechanical Final
809
Plumbing Final
813
Fire Sprinkler Test or Final
702
Swimming
Pools
Inspection Type
IVR INSP DATE
T -Bar Ceiling
145
Stucco Lath
142
Swimming
Pools
Setbacks
131
Pool Plumbing Test
504
Gas Test
404
Pre-Gunite
506
Pre -Deck
505
Pool Fencing/Alarms/Barriers
503
Pre -Plaster
507
Manufactured Homes
Setbacks
131
Blockin nde inin
612
Tiedown/Soft Set System
611
Permanent Foundation System
613
Underground Electric
218
Sewer
407
Underground Water
417
Manometer Test
605
Continuity Test
602
Skirting/Steps/Landings
610
Coach Info
Manufactures Name:
Date of Manufacture:
Model Name/Number:
Serial Numbers:'
Len th x Width:
Insignia:
*Project Final is a Certificate of Occupancy for (Residential Only)
PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF LiSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR
RENEWAL 30 DAYS PRIOR TO EXPIRATION
l
Butte County Department of Development Services FDRIM NO
PERMIT CENTER
7 County Center Drive, Oroville, CA 95965 DBI -01
-Cn Main Phone (530) 538-7601 Fax (530) 533-7735
Declaration of Installation
stallation
for Smoke Alarms and Carbon Monoxide Alarms
The newly adopted 2013 California Residential' Code requires the installation of Carbon
Monoxide Detectors in dwelling units and in sleeping units within which fuel -burning appliances
are installed. and in. dwelling units. that have attached garages.. The policy for Carbon Monoxide
Alarms in Butte County states "Any permitobtained•in which the value otwork.exceed`s 51000
associated with a Residential Group R. Dwelling Unit or Sleeping Unit shall conforrm. to the
following.201,3California Residential Code requirements for Smoke and Carbon Monoxide
Alarms (Section R31:4 & R31-5)."
Af ^'7013 Cali'forrila Residential Code requirements •tor Carbon. irlonoxide Alarms.-
"'.c.
R315-1 New cons+ttrikl on. An: approved carbon monoxide alarm shall be installed! in dwelling
units and in sleeping units within which fuel -burning appliances are installed: and; in dwelling
units that ha:ve•attached' garages.
R3,15_'I.2 Power supply:. For new construction required carbon monoxide alarms: shall receive
their primary power from the building wiring where such wiring is served from a co,mrmercial
_source.and_shalCbe--equipped..wRiha_ battery back-up. Alarm wiring shall be directly, con nectedta
the permanent building; wir[nq w[thout a disconnecting. switch other than as required, forover
current: pro6'e:ton, n ..
exceptions:
t. In dwelling units where there is no commercial. power supply the carbon monoxide, alarm maybe solely
battery operated.
2. In existing dwelling units a carboamonoxide alarm is permitted to be -solely battery operated- where.
repairsor alterations do not result: in the removal of wall and ceiling finishes
or there is- no access by means of attic, basement or crawl space.,
R31 5.1.3 Intemonnection. Where more than one carbon monoxide alarm is required to, be
installed within the dwelling unit or within a sleeping unit the alarm shall be interconnected Iry a
manner that activation: of one alarm shall activate all of the alarms in the individual unit.
?i:xce,p tion:
1. Interconnection is not required in existing dwelling units where repairs do not result in the
removal of wall and ceiling finishes there is no access by means of attic basement or craw
space and no previous method for interconnection existed.
R3,15.7 Where required in existing dwellings: Where a permit is required for alterations,
repairs or additions exceeding one thousand dollars ($1,000), existing dwellings or sleeping
units that have attached garages or fuel -burning appliances shall be provided with a carbon
monoxide alarm in accordance with Section R315.1. Carbon monoxide alarms shall only be
required in the specific dwelling unit or sleeping unit for which the permit was obtained.
R3'15.2.6 Aiarnn requirements: No person shall install, market, distribute, offer for sale or sell
any carbon monoxide device in the State of California unless the device and instructions have
been approved and listed by the State Fire Marshal.
Page 1 of 2
Carbon monoxide alarms required by Sections R3.15.1 and R315.2 shall be installed in the
following locations:
1. Outside of each separate dwelling unit sleeping area in the immediate vicinity of the
bedroom(s).
2. On every level of a dwelling unit including basements.
R315.1.5 Alultiple-purpose alarms: Carbon monoxide alarms combined with smoke alarms
shall comply with Section R315, all applicable standards, and requirements for listing and
approval' by the Office of the State Fire Marshal, for smoke alarms.
Butte County's Interpretation of 2013 CIRC, Sections 314 & 315 -or,
Smoke Alarms & Cazbon Monoxide Alarms,
Where alterations, repairs or additions exceeding $1,000 in valuation, existing dwellings shall be -{
retrofitted with smoke alarms and those that have attached garages or fuel -burning, appliances shall7hdve
caroon monoxide alarms installed. Existing smoke alarms can be replaced with dual function alarm's pr��
Smoke and Carbon Monoxide and in most cases will comply with the aforementioned code requirements
for Carbon Monoxide Alarms.
DECLARA71ON OF INS ULLAT9ON UNDER THE PENALTY OF PERJURY
As Owner/Contractor, 8lwe affirm and declare under the penalty of perjury, under the laws
of.@he-State-of Cali€ornia,,by-our-signatures-below-as Owner/Contractor; t;'iat Nwe-wili -- -
comply prior to final inspection with Iftems A & B as specified herein:
A. Both Owner/Contractor have read and clearly understand the aforementioned 2010
California Residential Code (CRC) Carbon Monoxide Alarm requirements.
B. Both Owner/Contractor are responsible for installing Carbon Monoxide Alarms prior to
final inspection as per the aforementioned building code and maintaining such
installation. Smoke Alarms will also be installed prior to final inspection as per the 2010
CRC. '
Smoke and Carbon Monoxide alarms are now installed in the following locations:
Owner's name (print): 7yl o
Owner's signature: PJL-�J�'J Date: &C1��
Contractor's name (print): CSLB License: 9-12 ,3s'/
Contractor's signature: Date: /--30014o°
Project Address: ,/d �l�c,.�i./ G+ /��n rw Permit #: 19—ol 7
Page 2 of 2
PROJECT OWNER:
,PETERS, TINA & DANNY
1 40 FELICIDAD LN.
CHICO, CA 95973
APN:047-430-054 PH#:(530) 518-5441
EMAIL:petersinvestments@sbcglobal.net
CONTRACTOR:
ALTERNATIVE ENERGY SYSTEMS INC.
13620 HIGHWAY 99
CHICO, CA 95973
CSLB: 853351 C-10, C-46
BUILDING JURISDICTION:
BUTTE COUNTY
DEPT. OF DEVELOPMENT SERVICES
7 COUNTY CENTER DRIVE
OROVILLE, CA 95965
OFFICEM (530) 538-7601
FAX#: (530) 538-2140
MON-FRI 8AM-3PM
INSPECTION LINE: (530) 538-4365
REQUESTS PHONED IN BY 2PM WILL BE
INSPECTED THE NEXT BUSINESS DAY
0
r
56�
SCOPE:
INSTALL PHOTOVOLTAIC SOLAR SYSTEM ON A TRUSS
ROOF, MOUNTED IN ACCORDANCE WITH ALL
APPLICABLE BUILDING CODES SPECIFICALLY
REFERENCING THE 2016 CALIFORNIA ELECTRICAL
CODE USING THE FOLLOWING SPECIFIC EQUIPMENT:
1. MODULES: SUNPOWER
(28) SPR -X21 -345 -D -AC
512 SQFT COVERED
2. INVERTER(S): SUNPOWER
(28) MODULE INTEGRATED 320W [S11]
3. SYSTEM:
8.96kW SYSTEM
SITE MAP
PAGE # CONTENT
PV -1.0 SCOPE
PV -2.0 SITE PLAN
PV -3.0 ARRAY LAYOUT
PV -4.0 ELECTRICAL DIAGRAM
PV -4.1 LABEL DIAGRAM
PV -5.0 GENERAL NOTES
ATTACHMENT MODULE SPECS
INVERTER SPECS
RACKING SPECS
WIRE CALCS
PETERS, TINA & DANNY
C n A poo - m 40 FELICIDAD LN.
3 p CHICO, CA 95973
O N APN:047-430-054 PH#:(530) 518-5441
13620 HWY 99
IHCOEneryyror[.1fe
(/�
CHICO, CA 95973 `-
ICO
, : (530) 345-6980 z
tJ���
FAX#: (530) 892-2360
Alternative Energy Systems Inc.
4CORREA
A PV -002217-013995
PV -022
info@soIarenergyforlife.com
PIOftlfpNl / j� Y -
(E) RESIDENCE
toe
*�
F` y
1` W
- - (E) COMPOSI_.N ROOF
W/ WOOD TRUSSES
AML
o
«y
q a
OCA'ON
_� .. •. S RVLCE P =L
4 '..•►. ' �' SITE PLAN
Q 9 °
S
PETERS, TINA & DANNY
-
13620 HWY 99 m
m <
o m ,
Z 3" m
> 9 �� o
40 FELICIDAD LN.
Energyrorllfe
I .
CHICO, CA 95973 `-
o
PHONE#: (530) 345-6980 z
g W
CHICO, CA 95973
! • }
IM&M00
FAX#: (530) 892-2360
Z
m
>
APN:047-430-054 PH#:(530) 518-5441
Alternative Energy Systems Inc.
RICARDOmnnea
info@solarenergyforlife.com
'
' �OyW-042217-013445
NO..."
`
10'- 511 ,.,
, • , - -
r
-
NOTES -
LEGEND'
-
DIRECT
n
1.ALL',ROOF PENETRATIONS
..'
,'
, •
4,
,$"
- "TOBE 7211 O.C: MAXIMUM
5'.PR
"
.,
'-10' PR
_ •.�.
3' PP �'♦
6' RR
}
10' RR
FIRE CODE
-
RECEPTICAL END CAP
s
ry;y
PLUG END CAP - 13
PARALLELE CONNECTION •
,.
,.
3
E.
31'-4"
f62�A29
Y
o
04
E.
E.
El
E
' -
RAFTERS 24" ON CENTER('—O"
'
- . <
1. -
,. - - - -
•
-
-
ATTACHMENTS MAX 6' ON CENTER
ARRAY LAYOUT
n
o6 DL s
PETERS, TINA & DANNY
•
13620 HWY 99
-
p
o
m„
frtergyfarUfe,,, CHICO, CA 95973
-
'
$
<
i
Z
n
z
A A
m
3
o o�
40 FELICIDAD LN.
PHONE#: (530) 345-6980
®.0
M
o
z
'
o
W
a p
-
o
oa
W "
CHICO, CA 95973'
FAX#:(530)892-2360
+�
'
APN:047-430 054 PH#:(530) 518-5441
-
Alternative Energy Systems
- ms Inc.'` ifi
no@$odreflergyforlife.com
RICARDO CORREA �.,
w-042217-013 4s.-
..
_
711 ; ..
I «
• M tnR.uaico
//'fns-•;, T , Y: , -
.------------.
CAT -5
I
i AC -1
SCIR:.22,000
ON ROOF w/
METER#: 1007641055
AC -MONITORING
(3) TRANSITION CABLE
AC -1
9
I WIRE RUN: 5'
(3)#10- 2 WIRE NM CABLE CU.
(2) #14 THWN-2 CU. &
IMP: 20A
WIRE RUN: 50'
9
10' cu. GRD.
WIRE RUN: 10'
WIRE
IMAX: 20A
10 ��
For Life
_�
13620 HWY 99p
CHICO, CA 95973
I ti
ACCORDANCE TO CEC2016
I ti
I
ARTICLE 705.12(D)(2)(3)(b)
JUNCTION
(28) PV MODULES/INVERTERS [SI11
I BOX
SUNPOWER: SPR -X21 -345 -D -AC
240V/lP/1.33A
— — — — — — — — — — — —
AC -2
(1) 3/4" EMT./
(3) #8 THWN-2 CU. &
(1) $110 THWN-2 CU. GRD.
WIRE RUN: 10'
IMAX: 47A
1
D
D
1
D
D
1
(N)AC DISTRIBUTION PANEL
'1251/ 1P/ 240V -
SERVICE VOLTAGE
120V=N-LI-L2=240V
120V=N-L2-L3=NAV
NAV -N -L3 -L1 -NAV
METER
CAT -5
1111111111111111111
SUNPOWER
SCIR:.22,000
MONITORING
METER#: 1007641055
AC -MONITORING
IIIIIIIIIIIIII
120 /o RULE
ROUTER
SERVICE VOLTAGE
120V=N-LI-L2=240V
120V=N-L2-L3=NAV
NAV -N -L3 -L1 -NAV
METER
(E) AC SERVICE PANEL
1111111111111111111
200A/ 1P/ 240V
SCIR:.22,000
METER#: 1007641055
AC -MONITORING
(1)1/2"EMT -/
120 /o RULE
'
(2) #14 THWN-2 CU. &
D
D
10' cu. GRD.
WIRE RUN: 10'
WIRE
PETERS, TINA & DANNY
40FELICIDADLN
DOWNSIZE MAIN BREAKER IN
For Life
_�
13620 HWY 99p
CHICO, CA 95973
ACCORDANCE TO CEC2016
ARTICLE 705.12(D)(2)(3)(b)
mNEnergy
s
Z
p
[S III SOLAR INVERTER INSTALLED IS A
1111111111111111111
.
SMART INVERTER PER CALIFORNIA RULE 21
ELECTRICAL DIAGRAM
D
D
PETERS, TINA & DANNY
40FELICIDADLN
For Life
_�
13620 HWY 99p
CHICO, CA 95973
mNEnergy
s
Z
p
O
p
C`z
,
APN:047-430-054 PH#:(530) 518-5441
i Alternative Energy Systems Inc.
RICARDORREA
O C
x A4CO 13015
FAX#:(530)892-2360
info@solarenergyforlife.com
•
L3�+i{I�i�7
aae„aw
It
AC PV ARRAY - - - -.DISCONN Cr +' MAIN •'r
•SUB PANEL •, .. f'` + -
• METER:.
., 1771r;71[;+71
��r � •- • ,mss + ti,
..
.� '~ a �� �� ���� - + . • - ..:"t .r - ` s-' ' . AMPS _
PHASE x
VOLTS "'
WARNING
UTILITY INTERACTIVE POWER
FLOWING THROUGH
KW SOLAR GENERATOR
fAC OPERATING VOLTAGE:
VAC/_PHASE WARNING
+ y -
RAPIDPHOTOVOLTAIC SYSTEM EQUIPPED
DUAL POWER SUPPLY
W. ITH
SHUTDOWN
.. �n
' Per CEC 690.54, Interactive Point of
i Interconnection installed at all Electrical
Per CEC 705.10, Point of Connection,
Distribution Panel covers that provide a path
`
from PV to Utility. Located On Main Service Panel.
,,, - • -- - � ' -
AC PHOTOVOLTAIC
DISCONNECT
.'.. i•F t a ,� Vii-. i' .y +T.,Y FOR ' ...' ••
Per CEC 690.14, Disconnection means at ,
,•• +
the single AC Disconnect or Main Breaker. - -
f SOLAR. NOT RELOCATE_
r i
r "
Solar breaker label @ any breaker passing _
• di: Directional Power +� ,
LABEL DIAGRAM' . •,F
m D S PETERS, TINA & DANNY t
o o m CnergyForUfe- C • —
3620 HWY 99 _ �• _
n < Z z 3 m 40 FELICIDAD LN. _ HICO CA 95973- o r `
c� 5. I n A o o PHONE#: (530) 345-6980 "' o
? ^ `� CHICO, CA 95973 I ��'
a 3 p A W - s' FAX#: (530) 892 2360 X.
APN:047-430-054, PH#:(530) 518-5441 Alternative Energy Systems Inca: -
D r RICARDO RRA - - info@solarenergyforlife.com
f
# PV-042217-013445
ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE 2016 CALIFORNIA ELECTRIC CODE (CEC), 2016
CALIFORNIA RESIDENTIAL CODE, 2016 CALIFORNIA BUILDIGN CODE ( STRUCTURAL), 2016 CALIFORNIA FIRE
CODE, 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE, LOCAL MUNICIPAL CODE, AND FIRE DISTRICT
REGULATIONS.
1. ALL EQUIPMENT SHALL BE LISTED AND LABELED PER RECOGNIZED ELECTRICAL TESTING LABORATORY AN
INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS.
2. ALL INVERTERS SHALL BE IEEE 929 COMPLIANT AND SHALL BE INSPECTED BY LOCAL UTILITY BEFORE
COMMISSIONING, TESTING, AND OPERATION OF THE SYSTEM.
3. ALL OUTDOOR EQUIPMENT SHALL BE MINIMUM NEMA 3R, INCLUDING OUTDOOR MOUNTED TRANSITION
BOXES, COMBINER BOXES, AND SWITCHES.
4. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF CEC ART.250,690.
5. CEC. ART. 690.9(A). ALL CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT
DEVICES LOCATED SO AS TO PROVIDE OVERCURRENT PROTECTION FROM ALL SOURCES.
6. CEC ART. 690.18. DUE TO THE FACT THAT PV MODULES ARE ENERGIZED WHENEVER THEY ARE EXPOSED
TO LIGHT, PV CONTRACTOR SHALL DISABLE THE ARRAY DURING INSTALLATION AND SERVICE BY SHORT
CIRCUITING, OPEN CIRCUITING, OR COVERING THE ARRAY WITH AN OPAQUE COVERING.
7. PHOTOVOLTAIC SYSTEM SHALL BACKFEED THE DISTRIBUTION SYSTEM ON SITE PER THE REQUIREMENTS OF
CEC ART.690.64(B). ALL BACKFEED BREAKERS SHALL BE IDENTIFIED AS SUCH AND SHALL BE SECURED IN
PLACE BY ADDITIONAL FASTENER PER THE REQUIREMENTS OF CEC 408.16(F).
8. FALL ARREST PROTECTION PER OSHA REQUIREMENTS SHALL BE PROVIDED FOR ALL ROOF WORK.
9. ALL CONDUCTORS AND TERMINATIONS SHALL BE RATED FOR 75° C MINIMUM.
10. CEC ART. 690.14. - SEE SHEET PV -4.1 FOR LABEL DIAGRAM
11. CEC ART. 690.53. - SEE SHEET PV -4.1 FOR LABEL DIAGRAM
12. CEC ART. 690.17. EACH AC DISCONNECT SHALL ALSO BE LABELED WITH: "WARNING! -ELECTRICAL SHOCK
HAZARD - DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIZE MAY BE ENERGIZED IN
THE OPEN POSITION".
13. GROUNDING OF ALL DWELLINS SHALL BE CONFIRMED.
14. CONTRACTOR TO PROVIDE GROUND FAULT PROTECTION FOR ROOF MOUNTED PHOTOVOLTAIC ARRAYS
LOCATED ON DWELLINGS PER 2014 CEC ART.690.17.
16. PROVIDE AN ACCESSIBLE DISCONNECT DEVICE THAT IS LOCKABLE IN OPEN POSITION AND IS
LOCATED WITHIN 10'-0" OF THE METER PER LOCAL ELECTRICAL UTILITY REGULATIONS.
17. PHOTOVOLTAIC SOURCE CURRENTS MUST BE RATED AT BOTH 125% OF THE PARALLEL
MODULE AND AT A CONTINUOUS LOAD OF ANOTHER 125% FOR A TOTAL OF 156% OF THE
LOAD.
18. PROVIDE PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE
DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECT MEANS IF THEY ARE
NOT IN THE SAME LOCATION PER 2016 CEC ART.690.56.
19. INSTALLATION OF PV PANEL ARRAYS SHOULD RESIST SLIDING AND POP-UP RESULTING FROM
SEISMIC EVENTS AND SHOULD COMPLY WITH CBC SECTION 1613A AND ASCE STANDARD 7-05,
CHAPTER 13.
20. PV SYSTEM INSTALLER WILL BE RESPONSIBLE FOR FURNISHING AND INSTALLATION OF ALL
RELATED EQUIPMENT, CABLES, ADDITIONAL CONDUITS, BOXES WIREWAYS AND OTHER
ACCESSORIES NECESSARY FOR COMPLETE AND OPERATIONAL PHOTOVOLTAIC SYSTEMS.
21. PV SYSTEM CONTRACTOR SHALL COORDINATE ALL THE WORK WITH THE ENGINEER, THE
CONSTRUCTION MANAGER AND ALL OTHER CONTRACTORS TO ENSURE THAT PV SYSTEM IS
INSTALLED AS SPECIFIED IN THESE DRAWINGS.
22. DRAWING IN GENERAL OR DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF THE
EQUIPMENT AND WORK INCLUDED. THE INTENTION OF THE DRAWING IS TO INDICATE SIZE,
CAPACITY, APPROXIMATE LOCATION AND GENERAL RELATIONSHIP, BUT NOT EXACT DETAIL
OR PHYSICAL PLACEMENT.
23. FIELD VERIFIES EXACT AIC RATING REQUIRED OF THE MAIN SWITCHBOARD FROM LOCAL
UTILITY.
24. A PV SYSTEM WITH MULTIPLE INVERTERS, WHERE INVERTERS ARE REMOTELY LOCATED FROM
EACH OTHER, WILL HAVE A DIRECTORY CREATED FOR EACH LOCATION. AS PER 2016 CEC
690.5(H) AND IN ACCORDANCE WITH 2016 CEC 705.10.
25. A NON FOLDING LADDER WILL BE IN PLACE AND SECURED TO THE ROOF TO PROVIDE ACCESS
FOR ALL INSPECTIONS. ALL J BOXES WILL BE OPENED UPON REQUEST.
26. SMOKE AND CARBON ALARMS WILL BE INSTALLED IN ACCORDANCE WITH CRC R314 R31
27. SOLAR INVERTER INSTALLED IS A SMART INVERTER PER CALIFORNIA RULE 21
6)
m
G
'°
.
0
PETERS, TINA &DANNY
CnNrgyForLlfeCHICO,
13620 HWY 99
CA 9597
3o
9
D
A A
o o
40 FELICIDAD LN.
I I
PHONE#: (530) 345-6980
o
g °�
CHICO, CA 95973
..
FAX#: (530) 892-2360 .
APN:047-430-054 PH#:(530) 518-5441
Alternative Energy Systems Inc.
RICARDOCORREA
a w-042217.0I3a45 .
info@solarenergyforlife.com
�'
z
Design -Driven Advantages
#1 module aesthetics and efficiency'
Unmatched module reliability,
No electrolytic capacitors
25 -year Combined Power and Product
Warranty
California Rule 21 Phase i compliant
Maximize Value for Roof
Size system for roof, not string inverter
Optimize performance of each module
Expand Deployment Options
Complex roofs and partial shading
Small systems
System expandability
Simplify & Speed Installation
Factory -integrated microinverter
Robust, double -locking AC connectors
Design flexibility offsite and onsite
No DC string sizing process _
Fewer installation steps than competing
systems
Intuitive commissioning
Component of Complete System
Built for use with SunPowefi' InvisiMount"I
and the SunPower Ulonitoring System (PVS5x)
Superior system reliability and aesthetics
SERIES .
Optimize System and Installation Efficiency
SunPow&r AC modules, which include a factory -integrated SunPower
:. microinJerter,,provide a revolutionary combination of high efficiency, high
reliability, and module -level DC -to -AC power conversion. Designed ,
specifically for use with.SunPower Invisilvount1m,andthe�SunPower -
Moriiioring System, SunPower AC modules enable rapid installation, best -
in -class system aesthedcs,'and intuitive visibility into system performance.
All this comes with ('he best Combined Power and Product Warranty in
the industry, - -
Grid Support Utility -Interactive Smart Inverter
SunPower's new Type D AC module is•UL tested and certified to UL 1741
SA and provides advanced smart inverter functions. SunPower Type D AC .
modules are fully compliant with the California Rule 21 Phase 1
requirements, and the Rule ;21 grid profile is easily set during
0
commissioning with SunPower PVS5x monitoring hardware.
sunpower.conn ;
Warranties 25 -year limited power warranty
25 ear limited product warranty
,UL listed to UL 1741 SA
SRDs: IEEE '1547-2003, IEEE 1547a-20'14, CA
Rule 21 Phase -1
PV Rapid Shutdown Equipment
Equipment Grounding, "
UL 6703, UL 9703 Connectors and cables
(load break disconnection)
1" UL 1741 AC Module (Type 2 fire rating)
Certifications Enables installation in accordance with:
• • NEC 690.6
NEC 690.12 Rapid Shutdown (inside and
outside the array)
NEC 690.15 AC Connectors, 690.33(A) - (E)(1)
- FCC and ICES -003 Class 8'
When used with InvisilVlount racking (UL 2703):
Integrated grounding and bonding
-.Class A fire rated
PID Test Potential -induced degradation free
n 1.oz In]
e
• - _
1107 mm
Operating Temp.
SPRX21-345-D-AC SPR421-345-D-AC
! SRD Profile
} 345 W 335 W
IEEE 1547a-20143
(default set ings)
min: I It se / max.
CA Rule 213
min. /•nom. / max.
! a ctor
' 21.5% 21.0%
59.5 /•60.0 /.60.5
53.5 / 60.0 / 60.5
Power
Power Factor
Three bypass diodes
0.99 / 1.00 / 1.00
,0.85 lead. / 1.00. / 0.85 lag.
I Reactive Power
-
±169 Var „
Volt-VAr•
'Voltage--
@240 V
' @208 V.
211.2 / 240 / 264 V
183 / 208 / 228.8 V
i; Max. Cu�reni.
@240 V
@208 V
1.33 A
1.54 A
112 in]
DC/AC CEC Conversion Efficiency
@240 V
@208 V
96.096
95.5%
Max.- Units Per 20 A Branch Circuis
@240 V
@208 V
12 (single phase)
10 (two pole) wye
Power
ie woos
320 W, 320 VA
'
No active phase balancing for 3 prase installations
SOMS current, LACCS FF and voltage. All DC voltage is fully contained within the module.
'� -
r.
Warranties 25 -year limited power warranty
25 ear limited product warranty
,UL listed to UL 1741 SA
SRDs: IEEE '1547-2003, IEEE 1547a-20'14, CA
Rule 21 Phase -1
PV Rapid Shutdown Equipment
Equipment Grounding, "
UL 6703, UL 9703 Connectors and cables
(load break disconnection)
1" UL 1741 AC Module (Type 2 fire rating)
Certifications Enables installation in accordance with:
• • NEC 690.6
NEC 690.12 Rapid Shutdown (inside and
outside the array)
NEC 690.15 AC Connectors, 690.33(A) - (E)(1)
- FCC and ICES -003 Class 8'
When used with InvisilVlount racking (UL 2703):
Integrated grounding and bonding
-.Class A fire rated
PID Test Potential -induced degradation free
n 1.oz In]
e
• - _
1107 mm
Operating Temp.
SPRX21-345-D-AC SPR421-345-D-AC
Nominal Power` (Pnom)
} 345 W 335 W
Power Tolerance
-+5/-O% +5/-0%
Avg. Panel Efficiency'
' 21.5% 21.0%
-Temp. Coe(. (Power)
-0.2946/°C
Recommended Max.
Module Spacing
Three bypass diodes
Shade Tolerance
Integrated module -level maximum power point
the top eight largest manufacturers were tested. 4mpeau, Z. et al. •SunPower Module
tracking
Warranties 25 -year limited power warranty
25 ear limited product warranty
,UL listed to UL 1741 SA
SRDs: IEEE '1547-2003, IEEE 1547a-20'14, CA
Rule 21 Phase -1
PV Rapid Shutdown Equipment
Equipment Grounding, "
UL 6703, UL 9703 Connectors and cables
(load break disconnection)
1" UL 1741 AC Module (Type 2 fire rating)
Certifications Enables installation in accordance with:
• • NEC 690.6
NEC 690.12 Rapid Shutdown (inside and
outside the array)
NEC 690.15 AC Connectors, 690.33(A) - (E)(1)
- FCC and ICES -003 Class 8'
When used with InvisilVlount racking (UL 2703):
Integrated grounding and bonding
-.Class A fire rated
PID Test Potential -induced degradation free
n 1.oz In]
e
• - _
1107 mm
Operating Temp.
-40' F to -+185' F (-40° C to +851 Q
Max. Ambient Temp.
122° F (50)e Q
Max. Load
Wind: 62 :)sf, 3000 Pa, 305 kg/m2 front & back
Snow: 12 5 psf, 6000 Pa, 611 kg/ml front
Impact Resistance
1 inch (25 mm) diameter hail at 52 mph (23 m/s)
Warranties 25 -year limited power warranty
25 ear limited product warranty
,UL listed to UL 1741 SA
SRDs: IEEE '1547-2003, IEEE 1547a-20'14, CA
Rule 21 Phase -1
PV Rapid Shutdown Equipment
Equipment Grounding, "
UL 6703, UL 9703 Connectors and cables
(load break disconnection)
1" UL 1741 AC Module (Type 2 fire rating)
Certifications Enables installation in accordance with:
• • NEC 690.6
NEC 690.12 Rapid Shutdown (inside and
outside the array)
NEC 690.15 AC Connectors, 690.33(A) - (E)(1)
- FCC and ICES -003 Class 8'
When used with InvisilVlount racking (UL 2703):
Integrated grounding and bonding
-.Class A fire rated
PID Test Potential -induced degradation free
n 1.oz In]
e
• - _
1107 mm
Solar Cells
96 Monocrystalline Nlaxeon Gen III
Glass
Front're1ective
Hiah7transmission tempered glass with anti-
coating
Environmental Rating -
Outdoor fated
Frame
Class 'I black anodized (highest AAIVIA rating),`
Weight
45.5 lbs (.0.6 kg)
Recommended Max.
Module Spacing
1.3 in. (33 mm)
Warranties 25 -year limited power warranty
25 ear limited product warranty
,UL listed to UL 1741 SA
SRDs: IEEE '1547-2003, IEEE 1547a-20'14, CA
Rule 21 Phase -1
PV Rapid Shutdown Equipment
Equipment Grounding, "
UL 6703, UL 9703 Connectors and cables
(load break disconnection)
1" UL 1741 AC Module (Type 2 fire rating)
Certifications Enables installation in accordance with:
• • NEC 690.6
NEC 690.12 Rapid Shutdown (inside and
outside the array)
NEC 690.15 AC Connectors, 690.33(A) - (E)(1)
- FCC and ICES -003 Class 8'
When used with InvisilVlount racking (UL 2703):
Integrated grounding and bonding
-.Class A fire rated
PID Test Potential -induced degradation free
n 1.oz In]
e
• - _
1107 mm
-
I
tHighest of over 3.200 silicon solar panels, Photon Module Survey, Feb. 2014
[436 In]
.
14 ta
a=1 rank in "PV Module Durability Initiative Public Report" Fraunhofer CSE. Feb 2013. Five out of
�
(41.2 in]
the top eight largest manufacturers were tested. 4mpeau, Z. et al. •SunPower Module
- Degradation Rate," SunPower white paper, Feb 2•a'13. See uvwm.sunpower.com/faas for details.
•
112 in]
'Fact set to 154 is -3014 default settings. CA ale 21 default settings profile set during
commissioning. See the Equinox Installation Guide #518101 for more information.
ie woos
'Standard Test Conditions (1000 Whm3 irradiance. AM 1.5, 25• Q. NREL calibration standard:
5W m)
SOMS current, LACCS FF and voltage. All DC voltage is fully contained within the module.
'� -
r.
mwrea�� eOMN
`Based on average of measured power values during production.
LISTED
'
Please read the safety and installation instructions for details. Module em Pe fo—ce' Type 2
See wmv.sunpower.com/facts for more reference information.
For more details, see extended datasheet:,Nww.-unpovyer.com/c]aLasheeEs.
518982 RevB
.j
Mid Clamp End Clamp
A Y
Module* / Mid Clamp and ?ail
Module* / End Clamp and Rail
Rail & Rail Splice
End Cap
InvisiMountOperatingConditions
_..
-40° C to 90° C (-40° F to 194° F)
Max, load
ou amp neat11-ails
Component
Matel ial
Weight
Mid Clamp
Black oxide stainless steel AISI 304
63 g (2.2 o_)
End Clamp
Black anodized alum -^um alloy 6063-T6
110 g (3.88 o:)
Rail.
Blackanodi_ed alum num alloy 6005-T6
830 g/m (9 o_/ft)
Rail Splice
Aluminum alloy 600575
830 g/m (9 o_/ft) .
Ground Lug .
s embly
304 stainless
(A2-70 bol[, tin, -placed copper lug)
106.5 g/m (3.75 o_)
=nd Cao
Black acetal (POM) ccpohjrrer
10.4 g (0.37 oz)
End Cap
InvisiMountOperatingConditions
Temperature
-40° C to 90° C (-40° F to 194° F)
Max, load
2400 Pa uplift
5400 ?a downforce . -
InvisiMount Warranties And Certifications
Warranties 25 -year product warranty
5 -year finish warranty
UL 2703 Listed
Certifications Class A fire rating when distance between
roof surface and bottom of Sunuower
module frame is _< 3.5"
Composition Shine Rarer Attachment. -
Application Composition Shingle Roof Decking Attachment RoofAt7tarchment• - Warranties
-
Curved and =tat Tile,Roof Attachment
Universal Interface for ocher Roof Attachments . Refer to roof attachment hardware manufacturers documentation
I%iod,tle frame that is compatible with the InvciYlount system ieyuired for hardware Interoperabllity,
D 2615 Sur.?ower corporation. All Rights Rese ved. SUN�OW _R, the SUN16WER logo, and INVISIMOUNT are trademarks or regstered '
trademar,S of Sur?ower Corporation, Ahothe trademarks are the property of their respective owners, sunpower.corn
Specifications included in this datasheet are subject to change without notice. Document #509506 Rev 3
INVISIMOUNT RACKING DETAIL
11V V 1J1111IJVIV I F\/11L
CLAMP
* EACH MID CLAMP
GROUNDS THE
UL
L -I VV I
[NVISIMOUNT RAIL
GreenFasten'" GF1 — Product Guide -
1
►,
5
Consult an engineer or go to www.ecofastensolar.com
for engineering data.
Installation Instructions with Compression Bracket
� � � �'�a,Y •�.3 ..�,-t`+,'Rr; Sp� i� r.,Fr� s t ��`�i� s",�`.F+�,e.7".
;4
Ni �wi Cy 1 �}�, 3;'t�,%y, � � �•j 'y r•+�i f r.� % '��
f•y tt,• `#!.'i�' + y�F t ls' V �� '�``i \' s cd -s.`,•=�,'
3745
t C •: �
�� ...�Y �'.^� �yy;� • -i:�yr it %�'��� �''J"� r.f.-. =�l�'�}�.
3 4a 4b ,4c
1. Locate the rafters and snap horizontal and vertical lines to mark the installation position for
each GreenFasten flashing.
2. Drill a pilot hole (1/4" diameter) for the lag bolt. Backfill with sealant. EcoFasten Solar
recommends an EPDM mastic.
3: Insert the flashing so the top part is under the next row of shingles and pushed far enough
up slope to prevent water infiltration through vertical joint in shingles. The leading edge of
flashing must butt against upper row of nails to prevent turning when tourqued. See page
2.2 for vertical adjustment when leading edge of flashing hits nails in upper shingle courses.
4. Line up pilot hole with GreenFasten flashing hole.
4a Insert the lag bolt through the EPDM washer, the top compression component bracket (L-
102-3, L-102-6*, SCL-101-3*, Z-101*, Conduit Mount Bracket*) and the gasketed hole in the
flashing and into the rafter.
4b Insert the lag bolt through the EPDM washer, the Comp Mount Slide compression
bracket and the gasketed hole in the flashing and into the rafter.
4c Insert the lag bolt through the SS washer, the third -party bracket, the EPDM bonded
washer, the CP -SQ -Slotted compression bracket and the gasketed hole in the flashing
and into the rafter.
5. Torque: The range is between 100-140 torque inch -pounds depending on the type of wood
and time of year. The visual indicator for proper torque is when the EPDM on the underside
of the bonded washer begins to push out the sides as the washer compresses. If using an
impact wrench to install the fasteners be careful not to over torque the fastener. You may
need to stop and use a ratchet to finish the install.
*not pictured.
877-859-3947 EcoFasten Solar4All content protected under copyright. All rights reserved. 7/24/2014 • . 2.1
EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 132 8,153,700 132 8,181,398 132 8,166,713 82 8,146,299 132 8,209,914 132 8,245,454 B2 8,272,174 132 8,225,557 132
_I111 GreenFasten"GF1 — Product Guide
Installation Instructions
* Use for vertical adjustment when leading edge of flashing hits nails in upper shingle courses
tir10
flashing3. Reinstall with notched area upslope.I Position notched leading edge underneath• •
trl� • • r ety beneath
a .,„�3}!`r `wx• �"`"'.ai7•yr,A�TpT77tlu x' �1r �*��".� LJ` �::•.i''A�{,w�7yft'
.:• �. f.�`i•�Fr3'ti ! r����ar� . - 4 'tL - . ;J3;�'`•Yf y��1}�=�l, i�S�y ' �.LL/'"�,r .� ,r asst
+� �' Sr4 �,yt��,r"w r,Y'.f�rj�, {`%t.�/�jp�k � .rya t..t+. „� 1ty�. 4�,Lk lwr �if� ����.�5-a T,t `fit � �- �•.
1 I `n "� � _{d � � 5 �7 . X a � lair ru v rat � t "r . ♦ .¢U v' fu
� � rai{.it„S,^�.ffa '., ,�, a,y ftc i'L � •t^�r� �"` w �i Sf i 3 I `^t P,J. "x y . W �rt� r rf j f� r•
� ® L���?+fix �' i`► v,� Tt`,�� ,j� �� S� "^"' xe�.V�,:rrY 'y .• lea x"5r�.,i �f �.�� ��` �}k i. ty��yL y� k� 1 � `��''`;
^;ice/ .3j3 tiC'. J� rf i f' si3iai ar:is` ;: l�asv�$i i }St rn sirV4'
r.�tr t r 3 sS �t i.,w •i
3
1 877-859-3947 EcoFasten Solari' All content protected under copyright. All rights reserved. 7/24/2014 2,2
EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153,700 B2 8,181,398 B2 8,166,713 82 8,146,299 B2 8,209,914 B2 8,245,454 B2 8,272,174 B2 8,225,557 B2
.Slide flashing up under shingles until leading edge ,
2. Remove flashing and cut"V"notch at marks where nail shafts
engages nails. Measure remaining distance to adjust
engaged leading edge of flashing the distance desired in Step 1.
�
upslope.
Notch depth not to exceed 2" length by 1/2" width.
t�t.'
1''�+
•, ; t�
`!
Nails beneath shingle
Placement of"V" notch
tir10
flashing3. Reinstall with notched area upslope.I Position notched leading edge underneath• •
trl� • • r ety beneath
a .,„�3}!`r `wx• �"`"'.ai7•yr,A�TpT77tlu x' �1r �*��".� LJ` �::•.i''A�{,w�7yft'
.:• �. f.�`i•�Fr3'ti ! r����ar� . - 4 'tL - . ;J3;�'`•Yf y��1}�=�l, i�S�y ' �.LL/'"�,r .� ,r asst
+� �' Sr4 �,yt��,r"w r,Y'.f�rj�, {`%t.�/�jp�k � .rya t..t+. „� 1ty�. 4�,Lk lwr �if� ����.�5-a T,t `fit � �- �•.
1 I `n "� � _{d � � 5 �7 . X a � lair ru v rat � t "r . ♦ .¢U v' fu
� � rai{.it„S,^�.ffa '., ,�, a,y ftc i'L � •t^�r� �"` w �i Sf i 3 I `^t P,J. "x y . W �rt� r rf j f� r•
� ® L���?+fix �' i`► v,� Tt`,�� ,j� �� S� "^"' xe�.V�,:rrY 'y .• lea x"5r�.,i �f �.�� ��` �}k i. ty��yL y� k� 1 � `��''`;
^;ice/ .3j3 tiC'. J� rf i f' si3iai ar:is` ;: l�asv�$i i }St rn sirV4'
r.�tr t r 3 sS �t i.,w •i
3
1 877-859-3947 EcoFasten Solari' All content protected under copyright. All rights reserved. 7/24/2014 2,2
EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153,700 B2 8,181,398 B2 8,166,713 82 8,146,299 B2 8,209,914 B2 8,245,454 B2 8,272,174 B2 8,225,557 B2
if
1.41
r "tj, 4111; , GreenFasten-GF1 - Product Guide . ` = t Cut Sheets: GF1
ij
1.11 i"�I���:II � �S^ � i, 1�tL , • - • ' - -` t _ • 1• �
'is
_____
____• __
___ \ J_ _______
_____
---------
s I/ 4 -
t' tibio Ik .� itrt 1 L Wo , . " • ). .� - . , - -
SECTION A A
r . 1 , iuvr.,� i e a 1• I . r _ • �' , - . • Y_ • . ! • + _ _ 4 . t - +. ^ • .
`r • _ :1 877-859-3947 EcoFasten Solari All content protected under copyright. All rights reserved. 7/24/2014 3;1
EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153,700 B2 8,181,398 62 8,166,713 B2 8,146,299 B2 8,209,914 B2 8,245,454 B2 8,272,174 B2 8,225,557 B2
,
! GreenFasten" GR — Product Guide Cut Sheets: GF1- 812
r
i14T.
tik' 3 , •
c l�ri ' . • 8" 4X R $ -��'� 1 /32" ± ;
8'
1.' i
k�P.sl,� k `� � 16 '
rk. A ?' (� �+ 5/64
�k' : ♦r ��Cl) 5
16
j • 1' k ` DETAIL A
4„ SCALE: 2:1
d,
t ;r' r' ;
— 6rt - • Finish Options:
BLK = Matte Black
MLL = Mill Finish .
" ! 877-859-3947 EcoFasten SolarAll content protected under copyright. All rights reserved. 7/24/2014 12
�- EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 132 8,153,700 82 8,181,398 132 8,166,713 132 8,146,299 B2 8,209,914 132 8,245,454 132 8,272,174 B2 8,225,557 132
GreenFasten"GF1 = Product Guide Cut Sheets: Bracket Options - CP -SQ -Slotted
till
a 1.50
0jj6 .50 ..
.38
1.00 ,
+ t J l _ 0.38'- T 0.50 .
1.00 .00
-°`!..# / \/ 0 0.88±.01 X 820
` yl' t` t °_ 2.00+ 1�
3. yt ' • J .
1 e ! 877-859-3947 EcoFasten Solan All content protected under copyright. All rights reserved. 7/24/2014 3.3
EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153,700 B2 8,181,398 B2 8,166,713 82 8,146,299 B2 8,209,914 62 8,245,454 82'8,272,174 B2 8,225,557 132
GreenFasten" GF1, — Product Guide ` +, - Cut Sheets: Bracket Options -SGL-101-3"
1 7 8" R 1 16
,
fit`+„r 3/4.. 1/16”
R.010
2X R.0 l
60.00° ,
s � • d ,� �.� � - „+.006 •
'0.3/8 -.002 /8
7/8„ X 82° • DETAIL A • + ~
SCALE 3:1
877-859-3947 EcoFasten Solai° All content protected under copyright. All rights reserved. 7/24/2014 -3.5
` EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153,700 132 8,181,398 132 8,166,713 132 8,146,299 132 8,209,914 B2 8,245,454 82 8,272,174 132 8,225,557 B2
GreenFasten'" GF1 — Product GuideCut Sheets: Bracket Options - L-102-3
l�f lit. • ��`. �� rf+ ,
�.,,V 2X 3/8" ,
1► t �t f� -
�It': m 14
46 SERRATIONS
�: °��'• 1!� t � it ..
3 t a,�
i lea in
Yl�r 1► +�rl
1 7/8"
+
CV
CV
x
04
'—
•
15/16"
1 7/8'
'1 /16"
;o R.005
; R.010
60.00°
i D f
'+006
, t } 3/8"- .002
1/8"
0.875±.010 X.82° � DETASCALE I -A 1
{, f
1 L ry 877-859-3947 EcoFasten Solar' All content protected under copyright. All rights reserved. 7/24/2014 3.6
i +1 f EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153,700 82 8,181,398 B2 8,166,713 B2 8,146,299 82 8,209,914 B2 8,245,454 B2 8,272,174 82 8,225,557 B2
System Specifications - - -
Customer Name:TINA & DANNY PETERS - Panel Specifications
• Customer Address: 140 FELICIDAD LN. , Chico, CA 95973 Manufacturer Sunpower Model: SPR -X21 -345-D AC
Service Panel Bus Bar Rating: 200 A - PV Pmax: 345 W. Length: 61.4 inches -
' Service Panel AC paramters: 240 V `, Vmpp: 57.3 V, Width: 41.2 inches
_t Total Solar AC System Size: 0.32 kW Voc: 68.2 V Weight: 411 lbs
•. Min Service Panel CB Size: 200 A' fll;,n7 Impp: 6.02 A r: Voc %Temp: 0.0025 V
Area Lowest Temp: -4 °C. Isc: 6.23 A, Voc Temp: 0.1674 V `
♦ _ +
!jvf6'r-1 Manufacturer Isunwiver
rT
A" Inverter ModelModule integrated
Inverter Output Power _ 320 W
Inverter Imax 1.3 A Min CB Size _46,6 A
String of 28 Actual CB Size 50 A
Voltage LZ40J VAC
Array String
DC Operating Voltage 1604:40 1604,40 VDG
DC Max Voltage 2050.22 205.0.22 VDC
DC Operating Current 6.02 6.02 A
DC Short Circuit Current 6.23 6.23 A.
Notes
Formulas
nl, NEC, Annex C, Annex C Table C
fl, Isc x 1.25 x 1.25
f7,# of series panels in series x Vmpp
n2, Conduit fill, NEC Table 310.15(B)(2)(a)f2,
•4`
Isc x 1.25/Conduit fill x (Ambient Temp - Sunlight Exposure Correction
f8,# of series panels x ((26C + Record Low Celcius x panel Voc temp Coef) +
n3, Temp correction, NEC Table 310.16
k
Factor)
Voc))
-
n4, DC Resistance, NEC Chapter 9 Table 8
•
f3, Inverter Imax x 1.25 ". • .
f9,# of strings x Impp M
n5, AC resistance, NEC Chapter 9 Table 9
t'
f4, Inverter Imax x 1.25/Conduit fill x (Ambient Temp -,Sunlight Exposure
f10,# of strings xlsc
n6, NEC Article 310.15• :
Correction Factor)
fll,Bus Bar or conductor rating x 1.2- Sum of all Input Breakers <or= Bus
n7, NEC Article 690.8(B)(1)
` `
f5, Tolerance % x V/D x I x ,2 l
bar or conductor rating x.1.2
—
n8, Sunlight Exposure,NEC Table, 310.15(13)(2)(c)
f6, .2 x D x I x R/V
r
AC Circuit Ampacity Calculator _ Meter #: I 1007641055 ,
Customer Name: PETERS, TINA & DANNY `� k
• 'Location:
140 FELICIDAD LN. , Chico, CA 95973
Wire Note: AC -1 Description: INVERTER TO AC DISTRIBUTION PANEL
"•' .' re Calculation _..�....c ��------ --- —_= - - .
• - 3.,84 kWatts 240 VAC - Split Voltage Configuration TRUE TL Inverter? '
L • t.
0 Minimum Wire and Conduit Size based on Voltage Drop and Ampacity 0 Minimum Ground'Siie'Based on NEC
20.00 A - Minimum Ciruit Breaker/Fuse Size 10 Actual Ground Size Based on NEC
20.00 A Ampacity After Derate _ 10 Wire Size Based on Ampacity r 30 A ,
0.496 % of Voltage Drop 10 Wire Size Based on Voltage Drop 30 A
16 A Circuit Ampacity 1_ Factor - . 1 Phases 1
0.96 Conditions of Use Derate Factor r ,•
16.67 A Minimum Conductor Ampacity. Based on Conditions of Use
20.00 A Minimum Conductor Ampacity Based on 1.25 Rule
Conditions of Use
. • 0.96 Derate Total
r 35 °C Temp Coef (ambient +.Sunlight) - 95 -F 0.96` Derate
35 °C Ambient Temp _ 95 °F
none Sunlight Exposure , 32 °F 00 °C Temp adder: s
3 or less Number of Current Carrying Conductors Lel Derate applied to Temp Coeficient `+ t
Voltage Drop:°Allowable Toierance (Solar Generation 1%, Distribution 3%)L
.240 V Circuit Voltage t16 A Circuit Amps 1.24 Resistance
30 ft , One Way Distance Wire Size 0.496 % of Loss
• Condu'it Size (Conduit FiII Can;Not,be more,•than-
' None Conduit Type 0.15 Wire Size Diameter Conduit Fill percentage -
_IN
Conduit Size 015 Ground Wire Size Diameter #N%Q Conduit Internal Diameter
500 V System Voltage THWN-2 Wire Type - ra
_• • + 1. ' ..a f. - } + - y
` J ,• < '• �'•• `� r '` Al ,e« 6 .. •'r'. , � f,
'r r" AC Circuit Ampacity Calculator . , Meter #: TWEE,5
Customer Name: PETERS, TINA & DANNY
Location: 40 FELICIDAD LN., Chico, CA 95973
` Wire Note: AC -2 Description AC DISTRIBUTION PANEL TO AC SERVICE PANEL t
Wi;66
lculation
8kWatts 240 _ VAC Split .Voltage Configuration .- TRUE TL Inverter? • ,
f Minimum Wire and Conduit Size based on.Voltage Drop and Ampacity Minimum Ground Size Based on NECA _Minimum Ciruit Breaker/Fuse Size f 10 Actual Ground Size Based on NEC
46.67 A Ampacity After Derate 8 Wire Size Based on Ampacity, - 55, A •_ ' "
0.2.42 % of Voltage Drop - 8 Wire Size Based on Voltage Drop,` 55 A •,` '
3.7.333 A Circuit Ampacity Factor _ - `' 1 Phases
0.82 Conditions of Use Derate Factor. -,
, 45.5A • Minimum Conductor Ampacity Based on Conditions of,,Use
_46.671A Minimum. Conductor Ampacity Based:on 1.25 Rule
Conditions,O,f_.
0.82 Derate Total
' 50 °C Temp Coef (ambient_ + Sunlight) 122 °F 0.82 Derate
50 °C -Ambient Temp 122 °F t c.
none Sunlight Exposure - 32 'F °C Temp adder. • '
f 3 -or less Number of Current Carrying Conductors r ___T1 Derate applied to Temp Coeficient
♦ Voltage Drop: Allowable Tolerance.,(SolarGeneration 1%, Distribution 3
�. • 240 V Circuit Voltage 87.333
JA Circuit Amps 0.778, Resistance :1 -
�=
10 ft One Way Distance ` 8, Wire Size 0.242 % of Loss • '
Conduit Size (Conduit FiII.C—an Not ,be more than 40%)
EMT Conduit Type 0.212 Wire Size Diameter 4 Conduit Fill percentage ti ;
3/4 'Conduit Size- • ♦ . ' ., 0.16 Ground Wire Size Diameterf 0.533 Conduit Internal Diameter '
600 V System Voltage THWN-2 Wire Type
-• � � r T ., '' • , . •.•'' 1. .• y �« ' .- •'t• •• `' ..f i -` • �• 1, A r'.` 3 � tT- - ,
E COUNTY
EVELOPMENT SERVICES
1 MUST BE ON JOB SITE
i30.538.4365 (Cut off time for inspections is Spm)
,t guarantee inspections on the date requested
x:530.538.7785 www.ButteCounty.net/dds
AREA
1.
Flood Zone: None SRA Area: Yes
Front: Centerline of Road:
Rear: SRA:
Street: AG:
Interior
Total Setback from Centerline of Road:
ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING
1 I
Inspection Type
IVR INSP DATE
Setbacks
131:
Foundations / Footings
111
Pier/Column Footings
122
Eufer Ground
216
Masonry Grout
120
Setbacks
131
Do Not Pour Concrete Until Above are Signed
Pre -Slab
124
Gas Test Underground/floor
404
Gas Piping Underground/floor
403
Underfloor Framing
149
Underfloor Ducts
319
Shear Transfer
136
Under Floor Plumbing
412
Under Slab Plumbing
41 f
Blockin /Unde inin
612
Tiedown/Soft Set System
611
Do Not Install Floor Sheathing or Slab Until Above Signed
Shearwall/B.W.P.-Interior
134
Shearwall/B.W.P.-Exterior
135
Roof Nail/Drag Trusses
129
417
Manometer Test
Do Not Install Siding/Stucco or Roofing Until Above Signed
Rough Framing
153
Rough Plumbing
406
Rough Mechanical
316
Rough Electrical
208
4 -Way Rough Framing
128
Gas Piping House
403
Gas Test House
404
Shower Pan/Tub Test
408
Do Not Insulate Until Above Signed
Inspection Type
IVR INSP DATE
T -Bar Ceiling
145
Stucco Lath
142
Plumbing Final
813
Fire Sprinkler Test or Final
702
Swimming
Pools
Setbacks
131
Pool Plumbing Test
504
Gas Test
404
Pre-Gunite
506
Pre -Deck
505
Pool Fencing/AlarmsBarriers
503
Pre -Plaster
507
Manufactured Homes
Setbacks
131
Blockin /Unde inin
612
Tiedown/Soft Set System
611
Permanent Foundation System
613
Underground Electric
218
Sewer
407
Underground Water
417
Manometer Test
605
Continuity Test
602
Skirting/Steps/Landings
610
Coach Info
Manufactures Name:
Date of Manufacture:
Model Name/Number:
Serial Numbers:
^
Length x Width:
Insignia:
t
.-o ;a. �7 's•s, i.. . f: r«w.- �'.- - a.•'ty.a a,. ,. +r n+ � x...* s .� :.+r �t.'.r•y ri •t 'f;4 r�:� �Tjt^ ��. '�tiY`.:^
c_ i i � � rJ �� a to j Y V,�,✓w n�f L:...r�k _>�� ;:.k. r � :\_. o.c a4, t �,
Permit Final
802
Electrical Final
803
Mechanical Final
809
Plumbing Final
813
Fire Sprinkler Test or Final
702
`
4r
Public Works Final 538.7681
Fire De artment/CDF 538.6226
Env. Health Final 538.7281
Sewer District Final
"PROJECT FINAL
*Project Final is a Certificate of Occupancy for (Residential Only)
PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR
RENEWAL 30 DAYS PRIOR TO EXPIRATION
A •
BUTTE COUNTY
DEPARTMENT OF DEVELOPMENT SERVICES
BUILDING PERMIT
,24 HOUR INSPECTION (IVR)#:530.538.4365
OFFICE #: 530.538.7601 FAX#:530.538.7785
www.ButteCounty.net/dds
U.:; a. ril-0' PROJECT INFORMATION.
Site Address: 3715 GRUBBS RD Owner:
APN: 027-160-012 CHRISTIAN MARCIA A
Permit type: MISCELLANEOUS 3715 GRUBBS RD
Subtype: SOLAR ROOF -RES I OROVILLE, CA 95966
Description: SOLAR ROOF - RES (10.175KW)
FREEDOM SOLAR SERVICES DBA
30605 SORREL LANE
CANYON LAKE, CA 92587
9513210855'
*1LICENSED. CONTRACTOR'S DE
FREEDOM SOLAR
30605 SORREL LANE
CANYON LAKE, CA 92587
9513210855
Contractor (Name) - State Contractors License No. / Class / Expires
FREEDOM SOLAR 982892 / C10 / 4/30/2019
I HEREBY AFFIRM UNCER PENALTY OF PERJURY that I am licensed under provisions of Chapter
(commencing with Secticn 7000) of Division 3 of the Business and Professions Code, and my license
in full force and effect.
X
Contractor's Signature Date
I HEREBY AFFIRM UNDER PENALTY OF PERJURY one of the following declarations:
❑I have and will maintain a certificate of consent to self -insure for workers'
compensation, issued by the Director of Industrial Relations as provided for by Section
3700 of the Labor Code, for the performance of the work for which this permit is issued. Policy
No.
❑1 have and will maintain workers' compensation insurance, as required by Section 3700 of
the Labor Code, for the performance of the work for which this permit is issued. My workers'
compensation insurance carrier and policy number are:
Carrier: STATE Policy Numb90522e9 Exp. 01'8)'1/2019
❑1 certify that, in the performance of the work for which this permit is issued, I shall not
employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the workers'
compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those
provisions.
Signature Date
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS
UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES
AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN
ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
I
I hereby affirm under penalty of pedury that there is a construction lending agency for the
performance of the work for which this permit is issued (Section 3097, Civil Code).
Lender's Name and Address
Lender's Name & Address City' State Zip
Ll,W'' Iar; FEE INFO
Total Fees: $512.00
Balance Due: (None)
Permit No: B17-2387
Issued Date: 10/6/2017 ' By JMD
Expiration Date: 10/6/2018
Occupancy: Zoning: A5
Square Footage:
Building Garage Remdl/Addn
0 0 0
Other Porch/Patio Total
0 0 0
w ._Xf-I T tom',• OWNER / BUILDER -DECLARATION ''-' ' .'
I hereby affirm under penally of perjury that I am exempt from the Contractors' State License Law for
the reason(s) indicated below by the checkmark(s) I have placed next to the applicable item(s) (Section
7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter,
improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors'
State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professions Code) or that he or she is exempt from licensure and the basis for the alleged exemption.
Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penally of
not more than five hundred dollars ($500).):
❑I, as owner of the property, or my employees with wages as their sole compensation, will
do U all of or U portions of the work, and the structure is not intended or offered for sale
(Section 7044, Business and Professiors Code: The Contractors' State License Law does not
apply to an owner of property who, through employees' or personal effort, builds or improves the
property, provided that the improvements are not intended or offered for sale. If, however, the
building or improvement is sold within one year of completion, the Owner -Builder will have the
burden of proving that it was not built or
improved for the purpose of sale.).
I, as owner of the property, am exclusively contracting with licensed Contractors to
construct the project (Section 7044, Business and Professions Code: The Contractors' State
License Law does not apply to an owner of property who builds or improves thereon, and who
contracts for the projects with a licensed Contractor pursuant to the Contractors' State License
Law.).
❑I am exempt from licensure under the Contractors' State License Law for the following
reason:
Owner's Signature Date
PERMIT APPLICANT.. DECLARATION
By my signature below, I certify to each of the following:
I am L) a California licensed contractor or L) the property owner' or U authorized to
act on the property owner's behalf
I have read this construction permit application and the information I have provided is
correct.
1 agree to comply with all applicable city and county ordinances and state laws relating
to building construction.
I authorize representatives of this city or county to enter the above -identified property
for inspection purposes. California Licensed Contractor, Property Owner' or
Authorized Agent": 'requires separate verification form —requires separate
authorization form
Fees Paid: $512.00
Job Value: $40,000.00
r
, ,t
f`1f
04
PHOTOVOL.TAIC SYSTEM' _ t _
y
PV'SYSTEM SUMMARY:_ 10.175 KW r CITY NOTES: �'f x
y: ,r ,' SITE LOCATION:.• -
THIS PROJECT COMPLIES WITH THE FOLLOWING: `
''ROOF MOUNT RESIDENTIAL PHOTOVOLTAIC SYSTEM
2016 CALIFORNIA BUILDING CODE (CBC)'. 4
f. -
SYSTEM SIZE (DC) : • ;STC: 37 X 275= 10175W. DC .2016 CALIFORNIA ELECTRICAL CODE (CEC)2016 CALIFORNIA FIRE CODE (CFC) kt
2016 CALIFORNIA PLUMBING CODE:
PTC: 37 X 249.20 = 9220.40W DC r
y 2016 CALIFORNIA MECHANICAL CODE - =
SYSTEM SIZE (CEC-AC) 37 X 249.20 X 98% = 9035.99W AC 2016 CALIFORNIA ENERGY CODE
2016 CALIFORNIA RESIDENTIAL CODE -
MODULES 37 X CANADIAN SOLAR ALL BLACK CS6K-275M, 275W 2016 CALIFORNIA ADMINISTRATIVE CODE
AS ADOPTED BY COUNTY OF BUTTE , t $",,; ` • `
i INVERTER . SOLAR EDGE SE760OH-US.
ROOF ✓COMPOSITION SHINGLE ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE
r - 1 MAXIMUM EXTENT POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR
TILT 21° PITCH 'r > o�.
_ TO THE SURFACE UPON WHICH THEY ARE MOUNTED
AZIMUTH 110°, 200° & 290° • r Y`
n VISIBLE PORTIONS OF THE SOLAR PANEL SUPPORT STRUCTURE AND ANY EXPOSED
2" X 6" RAFTER @ 24" O.0 ELECTRICAL CONDUITS, BOXES AND PANELS WILL NOT BE EXPOSED, AND WILL BE o • '
RAFTER/TRUSS SIZE COLORED MATCHED TO EXISTING ROOF OR SURROUNDING HOME.
FLUSH FOOT MOUNT WITH IRON RIDGE XR100 RAIL
ATTACHMENT TYPE MODULES SHALL BE TESTED, LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN '
r L
EXISTING 200 AMPS MSP WITH 200'AMPS MAIN ACCORDANCE WITH UL 1703. THE FIRE CLASSIFICATION SHALL COMPLY WITH TABLE
MAIN SERVICE PANEL 1505.1 OF THE CALIFORNIA BUILDING CODE BASED ON THE TYPE OF CONSTRUCTION OF ;
BREAKER OWTOP FEED THE BUILDING. CRC SECTION R902.4 SITE LOCATION
r SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED.PER CRC SECTION R314 AND
INTERCONNECTION TIED TO PV BREAKER IN.MSP 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD.
OCPD RATING 40 AMPS y RESIDENTIAL BUILDING UNDERGROUND ADDITION,OR IMPROVEMENTS SHALL REPLACE' HOUSE AERIAL VIEW:
NON-COMPLIANT PLUMBING FIXTURES WITH WATER CONSERVING PLUMBING FIXTURES IN
' 1 STRING; WITH 19 MODULES AND•1 STRING WITH 18 ' . ACCORDANCE WITH CGBSC '
STRINGING - SECTION301.1.1 AND CIVIL CODE 1101.1 AS FOLLOWS: '
• MODULES IN SERIES IN EACH STRING -WATER CLOSETS: 1.6 GPF (GPF= GALLONS PER FLUSH)
-FAUCETS (ALL INTERIOR) 2.2 ( GPM = GALLIONS PER MINUTE)
UTILITY PACIFIC GAS AND ELECTRIC COMPANY (PGE) -URINALS 1.0 GPF -
I '-SHOWER HEADS 2.5 GPM
TABLE OF CONTENTS
PV -1
SITE LOCATION AND HOUSE AERIAL VIEW
PV -2
SITE PLAN
PV -2A
ROOF PLAN WITH MODULES LAYOUT.
PV -3
ELECTRICAL LINE DIAGRAM
PV -4
ROOF MOUNTING DETAILS, ELEC., CALCULATION &'
MATERIAL LIST t -
PV -5
LABELS
INSTALLATION NOTES:.
THE PV BREAKER SHALL NOT EXCEED 120% OF THE ALLOWABLE BACK FEED OF THE MAIN
Ile
SERVICE BUSS RATING
'.{...CJs ti`'*'�, ,F. ll,A•:er•-Sj�;a—.• �_��f-�� a
PV WIRE SHALL BE USED ON DC RUNS FOR UNGROUNDED/TRANSFORMERLESS
INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK.- Ste. k ET,
1 A
EMT CONDUITS ARE ATTACHED TO THE ROOF USING PRESSURE TREATED WOOD IN CASE .
i
OF COMPOSITE ROOF OR COUN6UIT HANGERS IN CASE OF CONCRETE ROOF p�
1 -
ti !3
-
Eiectriul CoWaa°r"a
c
Freedom Solar -1o9s2ss2
- Freedom Solar Co
25819 Jefferson Ave, Suite 110, Murrieta, CA 9.2562 ;
Tel: (800) 385-1075 3
CLIENT:
CHRISTIAN, MARCIA- BH171202
3715 GRUBBS RD,
OROVILLE, CA, 95966
(530) 533-2044
t. '
REVISIONS:
DATE:
09/30/2017,
TITLE:
.
SITE, LOCATION AND
HOUSE AERIAL VIEW
~
SHEET:
.•
PV—�
DESCRIPTION DATE REVISION
DESIGN
BY:
GREG
JOB No.:
FS -09-195
F
1 '
I
ROOF AREA: 3079.69 SQ FT
SHED AREA : 751.35 SQ FT
SHED 1 AREA: 258.43 SQ FT
1
255'-11 "
I
i
i
43 i
PROPERTY LINE i
I
i
i
i
LnL
c Ico
61,
4.3'-
SHED
3,SHED 1
SHED
I
I
. I
I
I
I
GRVBBS RO
ROOF LI
(E) MAIN SERVICE PANEI
(N) 37 CANADIAN SOLAR ALL BL/
CS6K-275M, 27
I
I
I
I
I
I
I
I
I
I
--------------
SITE PLAN --(: 1
SCALE: 11128" = 1'-0"
el,a1-1 C,,,,,,, NI: CLIENT: REVISIONS: TITLE: SHEET:
y. Freedom Solar C-10982892 CHRISTIAN, MARCIA - BH 171202 DATE: 09/30/2017
DESCRIPTION DATE REVISION
3715 GRUBBS RD, DESIGN
Freedom Solar Co OROVILLE, CA, 95966 BY: GREG SITE PLAN PV -2
25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 (530) 533-2044
Tel: (800) 385-1075 JOB NO.: FS -09-195
r
7
2" X 6" RAFTER @ 24" O.0 (TYP.)
Qi (N) 3/4" EMT CONDUIT
(N) SOLAR EDGE SE760OA-US INVERTER
(N) AC DISCONNECT
(E) MAIN SERVICE PANEL—
A3(N)
ANEL
Q(N) JUNCTION-
4:6-
A2
UNCTIONS4:6„
Q (N) ATTACHMENT POINTS @
72" O.C. MAX.
(N) 37 CANADIAN SOLAR ALL BLACK
CS6K-275M, 275W
FIRE ACCESS POINTS
FIRE SETBACKS 1'-6"
TYP
NOTE:
EMT CONDUIT SUPPORTED BY PIPE
Q HANGERS 12" TO 18" AWAY FROM
ROOF EDGE
ATTACH CLAMP AT 25% FROM EDGE
AND 50% FROM CENTER OF MODULES
A\ JUNCTION BOX MOUNTED TO THE RAIL
LEGEND
® CHIMNEY
O PIPE VENT
ROOF PLAN WITH MODULES
SCALE: 1/128"= V-0"
Ele W.1 Comma«No: CLIENT: REVISIONS: TITLE: SHEET:
DESCRIPTION DATE REVISION
:. Freedom Solar C-10982892 CHRISTIAN, MARCIA - BH 171202 DATE: 09/30/2017
3715 GRUBBS RD, DESIGN GREG ROOF PLAN WITH PV -2A
Freedom Solar Co OROVILLE, CA, 95966 BY: MODULES LAYOUT
25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 (530) 533-2044
Tel: (800) 385-1075 JOB NO.: FS -09-195
ROOF AREA STATEMENT
ROOF
MODULES
PITCH
AZIMUTH
ROOF AREA
ARRAY AREA
1
7
21'
200°
267.65 SQ FT
125.80 SQ FT
2
16
21 °
290°
1258.40 SQ FT
285.91 SQ FT
3
1 14
1 21 °
110° 1
1273.73SQFTI
251.87 SQ FT
NOTE:
EMT CONDUIT SUPPORTED BY PIPE
Q HANGERS 12" TO 18" AWAY FROM
ROOF EDGE
ATTACH CLAMP AT 25% FROM EDGE
AND 50% FROM CENTER OF MODULES
A\ JUNCTION BOX MOUNTED TO THE RAIL
LEGEND
® CHIMNEY
O PIPE VENT
ROOF PLAN WITH MODULES
SCALE: 1/128"= V-0"
Ele W.1 Comma«No: CLIENT: REVISIONS: TITLE: SHEET:
DESCRIPTION DATE REVISION
:. Freedom Solar C-10982892 CHRISTIAN, MARCIA - BH 171202 DATE: 09/30/2017
3715 GRUBBS RD, DESIGN GREG ROOF PLAN WITH PV -2A
Freedom Solar Co OROVILLE, CA, 95966 BY: MODULES LAYOUT
25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 (530) 533-2044
Tel: (800) 385-1075 JOB NO.: FS -09-195
Ell
Max. OCPD:
(200A Bus) " (1.2) = 240A Max Rating (120% of Bus) '
a
PV Backfeed (40A) + Main Breaker (200A) _ (240A = 240A)
See 705.12 (D)(2)(3)(b) of 2016 CEC "
STRING -1
19 CANADIAN SOLAR ALL BLACK ,
CS6K-275M, 275W
(E) 200A MAIN
SERVICE PANEL
4 - #10 AWG, THWN-2
• 1 - #8 EGC, THWN-2
1 - #8 GEC, THWN-2
SOLAREDGE P320 IN 3/4" EMT CONDUIT (N) 40A /2P =�
�-POWER OPTIMIZERS PV BREAKER Alj — _—� --- INVERTER
I SOLAR EDGE
SE760OA-US
jRAPID SHUTDOWN.
STRING -2'
AC SWITCH R
18 CANADIAN SOLAR ALL BLACK
f CS6K-275M, 275W D 60A, AC
DISCONNECT
JUNCTIONCr
- o ;
I BOX
—� — —'—' I SOLAREDGE P320 I
I L-------------------
3 - #8 AWG, THWN-2
-----------------
POWER OPTIMIZERS L-________________
j 1 1 - #8 EGC, THWN-2
1 -#8 GEC, THWN- 2 L-___
_____________ ____J IN 3/4" EMT CONDUIT
2 - #10 AWG PV WIRE —� THE GROUNDING ELECTRODE
(E) 200A / 2P
MAIN BREAK
UTILITY
METER
1 - #6 EGC, BARE COPPER (TYP.2) - CONDUCTOR SHALL BE CONNECTED `
FROM THE ARRAY FRAME DIRECTLY TO
General Notes A GROUNDING ELECTRODE CONNECT TO EXISTING UFE
1. (37)•CANADIAN SOLAR ALL BLACK CS6K-275M, 275W wired and listed to UL1703 standards 8. System Grounding Electrode conductor for PV system to be sized to meet the requirements of CEC 2016 table 250.66,
not smaller than #8 CU AWG."
2. SOLAREDGE 760OH-US Inverter with integrated DC Disconnect and Arc Fault Protection. Attached with system
electrical specifications and ground fault protected & listed to UL1741 standards. 9. If the existing main service panel does not have a ground rod or ufer, it is the pv contractors responsibility install one.
3. Photovoltaic system ground will be tied into existing ground at main service from DC Disconnect/Inverter as per CEC 10. Smoke alarms and carbon monoxide detectors will meet the necessary requirements per CRC R314, R315
Sec. 250.166(A). "The Grounding Electrode Conductor shall not be smaller than the neutral conductor and not smaller
than 8AWG copper." 11. UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM.
4. Equipment operating 150 volts or greater shall only be serviced or replaced by qualified personnel. Field protection may 12.Terminals of the disconnecting means may be energized in the open position.
be in the form of conduit, closed cabinet or an enclosure which requires use of tools to open.
13. A signage labeled "SOLAR LOADS ONLY' is to be installed on dedicated solar sub panel to be used for PV only..
5. Solar Photovoltaic System equipment will be installed in accordance with requirements of Art. 690 of the 2016 CEC.
14. Solaredge inverters are listed to UL1741 and UL1699B standards.
6.Minimum height of conduit above roof to match temperature derating factor.
15. Solaredge Optimizers are listed to 1EC62109-1 (class II safety) and UL1741 standards.
7.Photovoltaic DC conductors entering the building shall be installed in metallic raceway and shall be identified every 10
feet -- and within 1 foot above and below penetrations of roof/ceiling assemblies, walls, or barriers -- with minimum 16. PV system is using continuous grounding method with #6 bare copper wire.
3/8 -inch -high white lettering on red background reading:"WARNING; PHOTOVOLTAIC POWER SOURCE"
eiae^�icA^�n�N° CLIENT: REVISIONS: TITLE: SHEET:
OFreedom Solar C-10 982892 CHRISTIAN, MARCIA - BH 171202 DESCRIPTION DATE REVISION DATE: 09/30/2017
3715 GRUBBS RD, DESIGN RE ELECTRICAL _
Freedom Solar CO OROVILLE, CA, 95966 BY: G G LINE DIAGRAM PV -3
25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 (530) 533-2044
Tel: (800) 385-1075 JOB NO.: FS -09-195
Ith
6"max
MATERIAL LIST
7-1
QTY,
EQUIPMENT
DESCRIPTION
ELECTRICAL CALCULATIONS
OPEN CIRCUIT VOLTAGE (Voc) :
PV MODULE,
SOLAR ALL .
MAX. POWER VOLTAGE (Vmp) :
31.3V
37
BY OTHERS
SHORT CIRCUIT CURRENT (Isc) :
PV MODULE,
CS6K-275M,
MAX. POWER CURRENT (imp):
8.80A
BY OTHERS
PTC RATING:
BACKFEED BREAKER SIZING
IRONRIDGE
RAIL
_ _ _ _
_ _ IRONRIDGE
MAX. CONTINUOS OUTPUT 32A @ 240V "
MAX. AC OUTPUT VOLTAGE RANGE:
211-240V
1
_
RAIL
MAX. AC OUTPUT CURRENT:
32A
(E) ROOF
MAX. AC POWER OUPUT :
(E) ROOF
32 X 1.25 = 40.0OAMPS. 40A BREAKER - OK
'
98%
MEMBRANE
JUNCTION BOX
MEMBRANE
1
AC DISCONNECT
600VAC, 60A, NEMA 3R, UL LISTED
1
PV BREAKER
2 POLE, 240V, 40A
74
CEC 705.12 (D) (2) (3) (b)
FLUSH FOOT MOUNT
300'
IRONRIDGE
IRONRIDGE XR100
IRONRIDGE
200 X 1.20 = 240
58
FLASHFOOT2
MID CLAMPS
FLASHFOOT2
END CLAMPS
IRONRIDGE XR100 END CLAMPS
50'
CONDUIT
3/4" EMT CONDUIT
240 - 200 = 40A ALLOWABLE BACKFEED
(E) BUILDING
(E) BUILDING
STRUCTURE
STRUCTURE
DE -RATED AMPACITY OF 8AWG CONDUCTOR @ 0.87
TEMPERATURE CORRECTION
55 X . 0.87 = 47.85 AMPS - OK
.
Existing composition
shingle roof
Ith
6"max
MATERIAL LIST
7-1
QTY,
EQUIPMENT
DESCRIPTION
CANADIAN
OPEN CIRCUIT VOLTAGE (Voc) :
38.3V
SOLAR ALL .
MAX. POWER VOLTAGE (Vmp) :
31.3V
37
BLACK`
SHORT CIRCUIT CURRENT (Isc) :
9.31A
CS6K-275M,
MAX. POWER CURRENT (imp):
8.80A
275W
PTC RATING:
249.2W
SOLAR EDGE
MAX. DC INPUT VOLTAGE:
350V
SE760OH-US
MAX. AC OUTPUT VOLTAGE RANGE:
211-240V
1
MAX. AC OUTPUT CURRENT:
32A
WITH POWER
MAX. AC POWER OUPUT :
760OW
OPTIMIZER
CEC EFFICIENCY:
98%
1
JUNCTION BOX
600VDC, NEMA 4X, UL LISTED
1
AC DISCONNECT
600VAC, 60A, NEMA 3R, UL LISTED
1
PV BREAKER
2 POLE, 240V, 40A
74
ATTACHMENTS
FLUSH FOOT MOUNT
300'
RAIL
IRONRIDGE XR100
IRONRIDGE XR100 GROUNDING
58
MID CLAMPS
MID CLAMPS
32
END CLAMPS
IRONRIDGE XR100 END CLAMPS
50'
CONDUIT
3/4" EMT CONDUIT
• IronRidge per PV Support
"Mininum 2.5" Lag Screw
Embedment -
Photovoltaic Panel Mounting Detail
Scale: NTS
Elect^wlcwao�No: CLIENT: ' REVISIONS: TITLE: SHEET:
Freedom Solar. c-10 982892 CHRISTIAN, MARCIA - 131-1171202�� DESCRIPTION DATE REVISION DATE: 09/30/2017
ROOF MOUNTING
3715 GRUBBS RD, DESIGN GREG DETAILS, ELEC. PV -4
Freedom Solar Co OROVILLE, CA, 95966 BY: CALCULATION &
25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 (530) 533-2044 MATERIAL LIST
Tel: (800) 385-1075
JOB No.: FS -09-195
LABELS:
LABELS SPECIFICATION:
1. ALL CAPITAL LETTERS
2. MINIMUM 3/8" LETTER HEIGHT
3. ARIAL OR SIMILAR, NON -BOLD
4. WHITE LETTERING IN RED
BACKGROUND
5. WEATHER RESISTANT MATERIAL
SUITABLE FOR THE ENVIRONMENT
(DURABLE ADHESIVE MATERIALS
MUST MEET THIS REQUIREMENT
6. ALL SIGNS SHOULD BE REFLECTIVE
CAUTION:
POWER TO THIS BUILDING IS ALSO
SUPPLIED FROM THE FOLLOWING
Q WARN I NG SOURCES WITH DISCONNECTS
LOCATED AS SHOWN
TURN OFF PHOTOVOLTAIC
AC DISCONNECT PRIOR TO
WORKING INSIDE PANEL
INVERTER EQUIPPED WITH
RAPID SHUTDOWN
AC DISCONNECT
MAIN SERVICE PANEL
JUNCTION BOX
37 PV MODULE
4�— EI-M-1Co,,a,NI: CLIENT:
Freedom Solar C-10 982892
Freedom Solar Co
25819 Jefferson Ave, Suite 110, Murrieta, CA 92562
Tel: (800) 385-1075
DISCONNECTION MEANS
ALL AC AND DC DISCONNECTS TO BE r
MARKED AS DISCONNECTING MEANS
PER CEC 2016 690.13(B)
AC DISCONNECT
REVISIONS: TITLE:
CHRISTIAN, MARCIA — BH 171202 DESCRIPTION DATE REVISION DATE: 09/30/2017
3715 GRUBBS RD, DESIGN
OROVILLE, CA, 95966 GREG LABELS
(530)533-2044
JOB NO.: FS -09-195
SHEET:
PV -5
PHOTOVOLTAIC DISCONNECT FOR
AC DISCONNECT
UTILITY OPERATION
ELECTRIC SHOCK HAZARD. DO NOT TOUCH
TERMINALS. TERMINALS ON BOTH THE LINE
WARNING
AND LOAD SIDE MAY BE ENERGIZED IN THE
INVERTER OUTPUT CONNECTION
FOR UTILITY OPERATION
INVERTER OUTPUT CONNECTION TO BE
OPEN POSITION.
DO NOT RELOCATE THIS OVERCURRENT
INSTALLED AT MAIN SERVICE PANEL
PHOTOVOLTAIC POWER SOURCE SHALL BE
DEVICE
WARNING
PER CEC 2016 705.12 (D)
ELECTRIC SHOCK HAZARD
MARKING SHOULD BE PLACED ON ALL INTERIOR.
690.12 COMPLIANT .
AND EXTERIOR PV CONDUIT, RACEWAYS,
PHOTOVOLTAIC SYSTEM, EQUIPPED WITH
ENCLOSURES, AND CABLE ASSEMBLIES, EVERY
RAPID SHUTDOWN,
10 FEET, AT TURNS AND ABOVE AND/OR BELOW
PERSONNEL FOR ASSISTANCE
PENETRATIONS AND ALL PV COMBINER AND
JUNCTION BOXES.
DIRECT-CURRENT PHOTOVOLTAIC
Nominal Voltage. 240 Volts
WARNING
POWER SOURCE TO BE INSTALLED AT
Nominal AC Frequency 60 Hz
WARNING
INVERTER PER CEC 690.53
ELECTRIC SHOCK HAZARD. THE DC
PHOTOVOLTIC POWER SOURCE
Maximum AC Current 40.00 Amps
CONDUCTORS OF THIS PHOTOVOLTAIC
Max.Overcurcent Device 40 Amps
SYSTEM ARE UNGROUNDED AND MAY BE
Max. Current per Pole 40.00 Amps
ENERGIZED.
OPERATING CURRENT: 17.9A
DISCONNECTING MEANS MAY BE
OPERATING VOLTAGE: 350.00V
ENERGIZED IN THE OPEN POSITION; TO
SHORT-CIRCUIT CURRENT: 23.62A ,
BE INSTALLED AT DISCONNECTING
MAX SYSTEM VOLTAGE: 500.00V
MEANS PER CEC 2016 690.17
REVISIONS: TITLE:
CHRISTIAN, MARCIA — BH 171202 DESCRIPTION DATE REVISION DATE: 09/30/2017
3715 GRUBBS RD, DESIGN
OROVILLE, CA, 95966 GREG LABELS
(530)533-2044
JOB NO.: FS -09-195
SHEET:
PV -5
WARNING
AC DISCONNECT
ELECTRIC SHOCK HAZARD. DO NOT TOUCH
TERMINALS. TERMINALS ON BOTH THE LINE
PHOTOVOLTIC DISCONNECT
AND LOAD SIDE MAY BE ENERGIZED IN THE
FOR UTILITY OPERATION
OPEN POSITION.
PHOTOVOLTAIC POWER SOURCE SHALL BE
WARNING
LABELED WITH THE FOLLOWING WARNING
ELECTRIC SHOCK HAZARD
AT EACH JUNCTION BOX, COMBINER BOX,
DISCONNECT, AND DEVICE WHERE
CONTACT QUALIFIED SERVICE
ENERGIZED, UNGROUNDED CIRCUITS MAY
BE EXPOSED DURING SERVICE PER
PERSONNEL FOR ASSISTANCE
CEC690.35(F)
Nominal Voltage. 240 Volts
WARNING
Nominal AC Frequency 60 Hz
Maximum AC Power 8350 Watts
ELECTRIC SHOCK HAZARD. THE DC
Maximum AC Current 40.00 Amps
CONDUCTORS OF THIS PHOTOVOLTAIC
Max.Overcurcent Device 40 Amps
SYSTEM ARE UNGROUNDED AND MAY BE
Max. Current per Pole 40.00 Amps
ENERGIZED.
REVISIONS: TITLE:
CHRISTIAN, MARCIA — BH 171202 DESCRIPTION DATE REVISION DATE: 09/30/2017
3715 GRUBBS RD, DESIGN
OROVILLE, CA, 95966 GREG LABELS
(530)533-2044
JOB NO.: FS -09-195
SHEET:
PV -5
V ti ° \ ^� �� I ^ OI� 1 T ENGINEERING DRAWING (mm) 'r 1. 'ALL' -BLACK CS6K'-280M / I-V CURVES
(C `J *r
A A
Rear Viewy , Frame Cross Section A -A to
-------------
IO �---� _____
GE E - .6 S x
YlountIng
r 3-- _- -"-_-_ ra• -
2 z _ 4 .2.--------------_ • a
Mounting Hole
a o'
~
y t 1 - - - - ----- -------
v
' ` ` f - • .- - y u I I g .. ' 5 10' 15 20 25 30 35 40 5 • 10 15 20 25 30 35 40 -
pp 6415. •t JA
L
1000 W/Soo W/m' , S q 25°C
t C600 WMY45•Cy-.,,•i 0 400 Wlm2 65•CALLBLACK- - ,
r .. u _ • -
�t- 4
CS6K-270 1 2751 290M y •'
r ELECTRICAL DATA I STC* c MECHANICAL DATA +
r • ' y ' All -Black CS6K 270M 275M 280M Specification Data '
Canadian Solar's ALL -BLACK CS6K-M modules are Nominal Max. Power (Pmax) 270 W 275 W _ 280 W Cell Type Mono -crystalline, 6 inch
equipped with dark mono -crystalline cells, a dark Opt. Operating Voltage (Vmp) 31.1 V 31.3 V 31.5 V Cell Arrangement 60 (6 x 10) -
colored backsheet and a black frame for enhanced 1 ; ` ' Opt. Operating Current (Imp) 8.67 A 8.80 A 8.89 A Dimensions _ 1650x992x40 mm (65.Ox39.1x 1.57 in)
aesthetics and reliable output. This product can # i� _ ` - Open Circuit Voltage (Voc) 38.2 V 38.3 V 38.5 V Weight 18.2 kg (40.1 lbs)
r s r
improve the aesthetics of a rooftop.4 ,'4; 4t ` .Short Circuit Current (Isc) 9.19 A 9.31 A 9.43 A Front Cover 3.2 mm tempered glass
Module Efficiency 16.50% 16.80% 17.11% Frame Material Anodized aluminium alloy
-„ Operating Temperature 40°C - +85°C J -Box IP67, 3 diodes
KEY: FEATURES , 2'a5 E linear power output warranty- Max. System Voltage 1000 V (IEC) or1000 V (UL) Cable 4 mm2 (IEC) or4 mm2 & 12 AWG .
' # Module Fire Performance . [{� 1000V(UL),1000 mm (39.4 in). r
TYPE 1 (UL 1703) or
t _ CLASS C (IEC 61730) Connectors T4 series or PV2 series ' +
+ Excellent module efficiency of. , �" ".ti Max. Series Fuse Rating 15A - Per Pallet 26 pieces, 520 kg (1146.4 lbs)
O u to 17.11% Y �_��.. product warranty on materials Y c - rt' '
,• p F Application Classification Class A Per Container (40' HQ) 728 pieces r, '
and workmanship - + `
Power Tolerance
0' SW A _
�.
r Outstanding low irradiance s .e
' ' , ^ .,.�.............:.........................................:........... , ' '� ` * 4. _,. ,' . • PUnder Standard Test Conditions (STC) ofirradiance of 1000 W/m', spectrum AM
'
O .-.... l 4 .« sTEMPERATURE,-
performance of up to 96.5 T 1.5 and cell temperatureof25`C. , +.
MANAGEMENT SYSTEM CERTIFICATES* z +4 f CHARACTERISTICS
L '1 Iso 9001:2008 / Quality management system " ELECTRICAL DATA I NOCT* Specification
S
Data ,
4?IP67 junction box for long-term J ISO 14001:2004 / Standards for environmental management system, .4 All -Black CS6K 270M -275M 280M_ Temperature Coefficient (Pmax) -0.41 % /°C 3
F t t •M IP67 Y weather', endurance �' �' OHSAS 18001:2007 / international standards for occupational health and safety f ' ' , Nominal Max. Power (Pmax) - 195 W, 199 W 202 W Temperature Coefficient (Voc) -0.31 % /°C V `
Opt. Operating Voltage (Vmp) 28.4 V 28.5 V 28.7 V Temperature Coefficient (Isc) 0.053 % /°C
Heavy snow load up to 6000 Pa, PRODUCT CERTIFICATES* * F _ '�. ' Opt. Operating Current (Imp) 6.87 A 6.95 A 7.04 A Nominal Operating Cell Temperature 45±2 °C '
F • ' * r IEC 61215 / IEC 61730: VDE / CE / MCS / CEC AU - _ r Open Circuit Voltage (Voc) 35.0 V- 35.1 V 35.3 V _ k
wind load up to 4000 Pa _ i �_- .
'- 7.44 A. 7.54 A. • 7.63 A
UL 1703 / IEC 61215 performance: CEC listed (US) Short Circuit Current (Isc)
UL 1703: CSA` ' a.
is - - ` • * Under Nominal Operating Cell Temperature (NOC1), irradiance of 800 W/m',-
r• Take -e -way - • ' - �, * ^ spectrum ambient temperature 20`C, wind speed 1 m/s.
';`, +- +'% 1 z ove -sp ` BBA✓e��:
PERFORMANCE AT LOW IRRADIANCE PARTNERSECTIONrr
Ito Outstanding performance at low irradiance, with an
"As there are different certification re uirements in different markets, lease contact - �`.• • Ve g -
f 1r t
k q P a ra a relative efficiency of 96.5 % from irradiances,-
�• - , ' • 4 r '' .'t ' your local Canadian Solar sates representative for the specific certificates applicable to ty • + t. r •. -
'* ` 4- the products in the region in which the products are to be used. - - f .i between 1000 W/m2. and 200 W/rn2 (AM 1.5, 25°C).
. 'it",. y ...... ............ .............................................................................
r 1
• u • + e d t ' CANADIAN SOLAR INC. is committed to providing high uali s '
f P 9 9 q ty . ' The specification and key features described in this datasheet may deviate slightly }
f' ' - _ roducts, solar -solar system solutions and services to customers . - _ and are not guaranteed. Due to on-going innovation, research and product
P y r E enhancement, Canadian Solar Inc. reserves the right to make anyadjustent , , ; �` a rT Y
m
.. - r t ,�` •'' around the world: As a leading PV project developer and ` - �" _ S, ?' „to he information described herein at any time without notice. Please always-
�_ obtain the most recent version of the datasheet which shall be duty incorporated
•,(`„ w _ - _`s,,, , - manufacturer of solar modules with over 17 GW deployed around 7 _s " _ , 'into the binding contract made by the parties governing all transactions related
- . - . e' • r ' r r Y "' • . • : ` - to the purchase and sale of the products described herein: ` - •R -
"q*. • s ; f+, the world since 2001, Canadian Solar Inc. (NASDAQ: CSIQ) is one of t.` }
the most bankable solar companies worldwide. A- F( •Caution: For professional use only. The installation and handling of PV modules
requires professional skills and should only be performed by qualified professionals.
7 • - ' c- = Please,read the safety and installation instructions before using the modules. • ..... .................... .. ......................--..... ... - -
+For detail information, please refer to Installation Manual. ' * - - ' - r'
k
.. _
q CANADIAN SOLAR INC. - . y . CANADIAN SOLAR.INC., Dec. 2016. All rights reserved, PV Module Product Datasheet V5.531_EN , t' • -
545 Speedvale Avenue West, Guelph, Ontario N1 K 1 E6, Canada, www.canadiansolar.com, su.pport@canadiansolar.com
solar.- • • - - •
SolarEdge Single. Phase Inverters..
for North America
SE3000H-US / SE380OH-US / SE5000H-US / SE_ 6000H -US /
• SE760OH-US
® err
• � 12-25-�..
teats...:-..�
i Wates
fa
a a
dp
�r
Optimized installation with HD -Wave technology
Record-breaking efficiency
Integrated are fault protection for.NEC 2011 690.11 and integrated rapid shutdown for NEC 2014 690.12
Extremely sural ��
—= High reliability without any electrolytic capacitors IllllltlHIN
Built-in module -level -monitoring `A,
Outdoor and indoor installation vv Ve
Optional: Revenue grade data, ANSI C12.20 Class 0.5(0.5% accuracy)
Optional: Self -Sustaining Power - produce up to L51<W directly from PV during grid failure
USA -CANADA -GERMANY -ITALY -FRANCE -JAPAN -CHINA -AUSTRALIA -THE NETHERLANDS -UK -ISRAEL -TURKEY -SOUTH AFRICA -BULGARIA www.solaredge.us-
Single Phase Inverters for North America
solar=ee
SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE760OH-US
SE3000H-US I SE380OH-U5 I SESOOOH-US I 5E6000H-U5 I SE760OH-US
I OUTPUT
Rated AC Power Output
...........
3000
3800 ....... 5000 ....... ..... 6000
7600...__......
VA
Max: AC Power Output
..............................................................................................................
3000
3800 5000 6000 .....................
7600
VA....
AC Output Voltage Min. -Nom. -Max. (183 - 208 - 229)
Outp.............................................
...................................................................
✓ - ..
.. ...........
Vac .
AC Output Voltage Min: Nom: Max. (211 - 240 - 264)
✓
✓ ✓.......... ....... ✓.. _..............
✓.........
.... Vac
..................................................................................................
AC Frequency Nominal
...q .... Y............p................................................................
59.3 _60:6051`"
Hz
Maximum Continuous Output Current 208V
24 ........:.................:....................
A
Maximum Continuous Output Current 240V
..................................
12.5
16 _.... 21 25
...
,32
A .....
GFDI Threshold
1
A
......................:..........................................................••---...............---Yes............................................................
Utility Monitoring, Islanding Protection,
Country Configurable Thresholds
INPUT
Maximum DC Power
.......................................................
4650
5900 7750 9300
.....................................................................
11800
�V
Transformer -less, Ungrounded
Yes
...
.. .. ...................... ....
Maximum Input Volta a
........................................................................................................................................................
..................................
480
..
Vdc
........
Nominal DC Input Voltage
...............................................................................................................
380
400
Vdc
Maximum Input Current 208V
........................... ...............................................................
15.5
............... ..... ...........:..... ....
Adc
Maximum Input Current 240V
...mInp.tCur Current 2 .......................................
8.5
10.5 13.5 16.5
20
Adc
Max. Input Short Circuit Current45
.........................................................................................................Yes.........................................
Adc
Reverse-Polarit Protecrion
Ground. Fault Isolation Detection
600kr-,Sensitivity -
........................................................
.........................................
Maximum ln\erter Efficiency
99
I 99.2
..................................................
... .......
...... K.....
........ ....................................................................
CEC Weighted Efficiency
.................................................................................
99 .................................
„••�?,,,•
Nighttime Power Consumption
< 2.5
W
i SELF-SUSTAINING POWER OUTLET (OPTIONAL)
Nominal Output Voltage
120
V
Maximum Output Power
....................................................................................
1500 .........................
I W
External Outlet with GFDI
I
Yes
+: ADDITIONAL FEATURES
Supported Communication Interfaces
R5485, Ethernet,,ZigBee (optional), Cellular (optional)
............
............................................................................'E*,,
Internal RGM support
AN51 C12 20 class 0.5 compliant
..........
Rapid Shutdown - NEC 2014 690.12
Automatic Rapid Shutdown
STANDARD COMPLIANCE
Safety ...........................................................................................................................................................
UL1741, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07
Grid Connection Standards
ion Stan ..................
IEEE1547, Rule 21, Rule14 (HI)
EEE1 ...........,Rul......................................................
.........nnec
Emissions
FCC Part 15 Class B
INSTALLATION SPECIFICATIONS
AC Output Conduit Size / A\NG Range
0.75-1" Conduit / 14-6 AWG
....................................................................................................Con................................................................
DC Input Conduit Size /Hof Strings / AWG Range
0.75-1" Conduit /1-2 strings / 14.6 AWG
Dimensions with Safety Switch (HxWxD)
.......I ............. ....... .......................................................................
17.7 x 14.6 x 6.8 /-450 x 370 x 174
...................................
.. ...........
in/mm
Wei ht with Safety Switch...............................................................
25.3/11.5
Ib / kg
......
.......................
Noise<.25
...................
BA
Cooling ..........................
..Ra..nge
......................Natural...Convection... .............:........................
............
....................................................
Operating ..Tempe..rature
: 13 to+140 / .25 to +60f3j(-40•F / -40°C option)
...................... ..............................
_
/ .... .
Protection Rating
--.............................................................
NEMA 3R (Inverter with Safety Switch)
...... ......... ........... ...................
...
01 For ocher regional settings please contact SolarEdge support
Ixi Depends on Pv availability
-
• �a�Power de -rating from 50'C
`
*. sola 0.0 .0.
`. SolarEdge,Powe'r0paimizer
s. Module'Add-On For North America
P300 /.-P320-/ P400 / P405•
• o
99
0
li=
a
r _ • r
PV power optimization at"_the`m6dule=level
�1up to 25% more energye a _ .,a• r - _,
Superior. efficiency (99:5%) a - F
r a.' = a • "
-.Mitigates all types of module mismatch losses;'from manufacturing tolerance to;partial shading ,..
;." Flexible system design -for maximum space utilization-. "r-
Fast installation with a'single bolt
Nextgeneration maintenance with module -level monitoring '
-:Module level voltage shutdown for installer and firefighter safety T
USA-CANADA-GERM.ANY-ITALY-FRANCE -JAPAN -CHINA -AUSTRALIA -THE NETHERLANDS-UK=ISRAEL -TURKEY-SOUTHAFRICA--BULGARIA www.solaredge.us
CE Ei�
n SolarEdg TerhnologigZ Inc. All r,nts rescncd. SOLAREDt9E, the SolarEdgcjogo. OPTIA9ZED 6Y-OtAREDGE
dre tradenrarHsc r toginlered tr den,arks of SoIerEdeo .Ichnule�i i All ether lradmuterly rnru;i.f!vd hemi', are
traeen•.ar,es of their reso=rtive "nen'. < D]j29i7 v.ni*Snhiecilo change .;nhou1 notice.
solar - 0 0 SolarEdge Power Optimizer _
` Module Add -On for North America
P300'/ P320 / P400 / P405''•
Y
-
r k.
•
P300
P320
P400
_ P405
,
(for 60 -cell modules)
(for high-power
(for 72 & 96 -cell
(for thin film
.
`
60 -cell modules)
modules)
modules)
IINPUT '
:Rated Input DC Powerltl
300 320 400 405
...... .......................... ............... ... .
W
.. ...
Absolute Maximum Input Voltage
48 80 125
Vdc
�Vo . at lowest temperature)
.................. :.......:.:..,............
...........:.
MPPT Operating Range
...........
8-48 48 8:80 _ 12.5-105
.......................... .........................
Vdc
........
Maximum Short Circuit Current (Isc)
10 11 • .. 10.1
.....................................................
I
Adc
.............
....................................
Maximum DC Input Current
..................� ......
12.5 13.75' 12.63
..........................1.......................... ....................
Adc
.............. 'ci'e ......................
Maximum Efficiency
...._.....• 995 '
°�
Weighted Efficiency .....
............... 98.8 .............
..
OvervoltagaCategor.y.............
II -
r OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)
Maximum Output Current
.....-... "n.............
15
.......................................................................................
. Adc
Maximum Output Voltage
60 85
Vdc _
i OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) '
Safety Output Voltage per Power
r , ,
Vdc
Optimizer
I STANDARD COMPLIANCE
EMC
FCC Part15 Class B, IEC61000 :6.2, IEC61000.6.3 ....................
.............
Safety • <
..............
....................
.` IEC62109 1 (class II safety} UL1741 -
. :...
.............
RoHS -
' • Yes
INSTALLATION SPECIFICATIONS
Maximum Allowed System Voltage
....................... ..
` 1000
...............I........................ .............................. .... .
Vdc
.. ....
Compatible inverters, .
All SolarEdge Single Phase and Three Phase inverters _. .
. ............................
.. ..
..........
•� x� Dimensions (W x L x H).
128x152x27.5/ 128x152 x35/ 128x152x50/'-
'3
/ in
;.♦
5x5.97x1.08 . Sx5.97x1.37 5x5.97x1.96
............................................
Weight (including cables).....•.........
................. I...........
. ....6.3..0./.1.4..................... ...`.....750.(1x......:.........845 / 19.......
... �� / lb... ,
Input Connector ........I..........
MC4 Compatible r
.............................................. .........................
.............
Output Wire Type /Connector
'. Double Insulated; MC4 Compatible
Output Wlre Length ............'.:...
`..0.95 / 3 0.. �.. 1.2/3.9., ..........-...:.....
.................. ........... ...........
m / ft
............
Operating Temperature Range.
40.-.+8.5./.-40.-.+.1.85
........................................................................
•
tC / F . .
Protection Ratin
................ g .............. ....:.
IP68 / NEMA6P '
.........................-. ... ................
_
RelativeHumidity......................
.................`................................ 0.:100...:'................:.......:..:................::....
0.
• t'I Rated STC power of the module. Module of up to +5% power
tolerance allowed.
= PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V -
A SOLAREDGE INVERTER1�1
r
Minimum String Length
.$ " 10 I18
. 1
.
�.
(Power Optimizers)
,
. ' ........... ...............
.... ....
.........
a Maximum String Length
..........................._...-- ••--•••-.
r
2525 •, 50 T
:
- Power O timlzers
r
- ,
r
Maximum Power peString...........
.................... .... .......:.::.....
5250 6000 12750 .....
W
..... ....
t......
Parallel Strings of Different Lengths.
Yes L
s
V. or Orientations `'
_ * f
..................
tat It is not allowed to mix P405with P300/P.00/P600/P700
m one string. , �, `"f • _ " ,
` c -
CE Ei�
n SolarEdg TerhnologigZ Inc. All r,nts rescncd. SOLAREDt9E, the SolarEdgcjogo. OPTIA9ZED 6Y-OtAREDGE
dre tradenrarHsc r toginlered tr den,arks of SoIerEdeo .Ichnule�i i All ether lradmuterly rnru;i.f!vd hemi', are
traeen•.ar,es of their reso=rtive "nen'. < D]j29i7 v.ni*Snhiecilo change .;nhou1 notice.
y /Ad I RON RI DGE =
XR Rails
Flush Mount. System k
r F , 1 i•
tXR10 Rail-,-XR100 Rail XR1000 Rail Bonded Splices
_ A low -profile mounting rail' The ultimate residential A heavyweight mounting �, All rails use internal splices
• for regions with light snow.. solar mounting rail. rail for commercial projects. for seamless connections.
A • 6' spanning capability's . 8' spanning capability • 12' spanning capability Self -drilling screws
' - Moderate load capability- • 'Heavy load capability • Extreme load capability .Varying versions for rails
'Clamps & Grounding O
UFOs• Stopper Sleeves Grounding Lugs Microinverter Kits
404 8ko
1L
_ _-------- `� _ Universal Fastening Objects Snap onto the UFO to turn Connect arrays to Mount MIs or POs to XR
bond modules to rails. into a bonded end clamp. equipment ground. Rails.
�Ir • Fully assembled & lubed Bonds modules to rails Low profile Bonds devices to rails
�. • Single, universal size 6 different sizes Single tool installation Kit comes assembled
• Clear & black finish Clear & black anod. finish Mounts in any direction ' • •Listed to UL 2703
` Built for solar's toughest roofs: • _ -
Attachments O
IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to • • _ -
the limit and proven in extreme environments: • FlashFoot2 Slotted L -Feet , `' Bonding Hardv✓are' Flush Standoffs
E Our rigorous approach has led to unique structural features,,such•as curved rails and reinforced flashings, and; _ • r _ • , ,
is also why our products are fully certified, -code compliant and backed by a 20 -year warranty.ff
• ' `
q
L•- � _ ^r Y ' + t - - - +- r ctik ��, Vit.. : • - E•
PE CertifiedStrength Tested
` IAL�1 All components evaluated for superior «►//1 Pre -stamped engineering letters Flash and mount XR Rails Drop-in design for rapid rail. Bond and attach XR Rails Raise Flush Mount System .
structural performance: ��� available in most states. with superior waterproofing.. attachment. .to certified attachments. •- '. to various heights.
_Twist -on Cap eases install Secure rail connections: T &Square Bolt options' - Works with vent flashing
•• '
Wind -driven rain tested Slot for vertical adjusting • F •Nut uses 7/16" socket '' _, • 4" and 7" lengths
Class A Fire Rating _ Design Assistant• Mill & black finish , Clear & black anod. finish Assembled & lubricated Ships assembled,
Certified to maintain the•fire resistance Online software makes it simple to
rating of the existing roof: create share, and price projects. :' Resources
Design Assistant ' r
UL 2703 Listed System , 20 -Year Warranty - = _-; - Go from rough layout to fully
engineered system. For free.
Entire system and components meet O Twice the protection offered by '
Go to IronRidge.com/design
newest effective UL 2703 standard. competitors.
�. - . 3933•US Route 11 r }'
_ , Cortland; NY 13045 z x
I Intertek
$ " •Telephone: (607) 753-6711
Facsimile: (607) 756-9891
' • r t . www.interiek.com•Tecnologies Ltd" port f
- . June 20, 2014 s .r. Letter Report No. 101703554CRT-001 �` `'` f F r June 201h, 2014, �� "''' ,•
x • . ,•' >' Project No. G 10 1703554
- t'f f r,
r. .x x F + • 3-ph Inverters:'
Mr. Meir Adest ` y . Ph: +972.9.957.6620 ' • +
. o SMUS / SE10KUS / SE20KUS when the SolarEdge rapid shutdown cable labeled "MCI-CB-xxxxx- -
SolarEdge Technologies Ltd " ;email: meir.a@solar`edge.com'• _ _ -h '.
y ' ±� x" which -is part of kit SE1000-RSD-xx is installed in the inverter Safety Switch where xxxxx-xz is
6 Ha'Harash St. • • ,
* HOD HASHARON, ISRAEL ', - ' ' any number; inverter part number may be followed by a suffix
Subject: ETL Evaluation of SolarEdge Products to NEC'Rapid Shutdown Requirements - •> 'f
'This letter report completes this portion of the evaluation covered by Intertek Project No.G101703554. "
Dear Mr. Meir Adest, t ;
,.• ',y - If there are-any questions regarding the results contained in this report, or any of the other services offered by
This letter represents the testing results of the below.listed products to the requirements contained in the following : Intertek, please do not hesitate to contact the undersigned.
< standards: .. - ,. _ * - ' Please note, this Letter Report does not represent authorization for the rise of any Intertek certification marks.
National Electric Code, 2014, Section 690.12 requirement 'for rapid shutdown.
CmebyRadhe Patel iewed �d v: Howard Liu
This investigation was authorized b signed Quote 500534459 dated 06/10/2014. Ra id'shutdown test were ' Tltle:. , Engineering Team Lead ' Title: Staff Engineer t
9 Y 9 P p ,
_ perform at SolarEdge Technologies Ltd, 6 Ha'Harash St HOD HASHARON, ISRAEL and witness by Intertek _ - ��� �� 21 / `�. • ,_
n personal on 06/17/2014. - Signature: Signature
`._ { •
The evaluation covers installations consisting of optimizers and inverters with part numbers listed below.* Date !June 20 , 2014 k Date:j June 20 , 2014
The testing done has verified that controlled conductors are limited to not more than 30 volts and 240 volt- '
amperes within 10 seconds of rapid shutdown initiation. , ' - • '
41
Applicable products:
*'. r x • Power optimizers: - : 4 ry : , • ; z 'r ;
t ' o -•PBxxx-yyy-zizz; where xxx is any number, 0.9, up to a maximum value where xxx = 350; jryy
" •, could be AOB or TFI; an`d zzz; is any combination of four letters and numbers.
_ o OP-XXX-LV, OP-XXX-MV, OP-XXX-IV, OP-XXX-EV; where xxx is any number, 0-9.• �� f f - x ` ' '
• o Paaa, Pbbb, Pccc, Pddd, Peee; where aaa, bbb, ccc, ddd, eee is any number; 0-9 to a maximum.
` upto aaa=300, bbb=350 ccc=500, ddd=600, eee=700. 1 •' ;•. - t'
t o Pxxx, Pyyy, Pzzz, Pmmm, Pnnn and P000; where xxx, yyy, zzz is any number, 0-9 to a maximum
up to xxx=300, yyy=350, zzz=500; where mmm, nnn, 000 is any number, 0-9 to a maximum up to -` - ' := ' " •, <i _ t - " `
• mmm=405; nnn=300, 000=350 . •r E '• µ h
- s • 17ph Inverters: -• _ ' Y - f a �' • '� F ` i �r, `,y , -iy� ; } y t
o SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE7600A-US / SE10000A-US % "r - ` . • '
SE11400A-US when the SolarEdge rapid shutdown cable labeled."MCI-CB-xzxxx-x" which is part w .~ ) •'k" '
of kit SE1000-RSD-xx is installed in the inverter Safety Switch where xxxxx-xx is any number;. s
z - 'inverter part number may be followed.by a suffix'. {. ' r a d + `f ' '-�• `� , ' z: - ;
::� �• - y - -Y 'y Page1`of2'• ►r n t '."
• ",r _ f, This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms - . _ _ - - rt , , ' . • p - - -
+ "r and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use , .' , - % '"" ' - •ds • - .�. , a +
- e ' '�; ' • of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or - . < _ r.,F. `F , rt' ._ s - r ' -r ► ''`" ' y. i
• - advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only the sample tested. This . f J - - �. r i tF l'• .• `"tf •� „r _5, _ i a.!,'�- • - ,
report by itself does not imply that the material, product or service is or has ever been under an Intertek certification program. , _ j , - , ,,. , ,-.� , '" - F _- - ,•; �•
®M sO BEAB Intertek t . ' r,. �.. i Page 2 of 2 '`"
_ O
Intertek Intertek' Intenek Intertek Intertek Intertek " s `
• Intertek Testing Services NA, Inc. ' S012.1 .2 (11/11/10) Informative •
• Intertek Testing Services NA, Inc. ; `•, SD 12.1.2 (11/11/10) Informative'
!- Report No. 101541132LAX-002 �a ,: ;Page 2 of 86 ' ' Issued: 22-M6y-2014 • ,
CLASSIFICATION" IronRidge, Inc. Revised: 15 -Jan -2016
r .
Constructional Data_;Report (CDR) '
'1 A Reference and Address". s r
Re ort Number
1o1s41132Lax-oo2:: ,' Original 22 -Ma -2014 Revised: 15 -Jan -2016
Brand name:..,,,
UL Subject 2703'Outline of Investigation for Rack Mounting Systems and Clamping Devices'
•s .
for Flat -Plate Photovoltaic Modules and Panels, Issue Number: 1, October 4, 2010
Applicant,
IronRidge, Inc.
Manufacturer.1
!- Report No. 101541132LAX-002 �a ,: ;Page 2 of 86 ' ' Issued: 22-M6y-2014 • ,
CLASSIFICATION" IronRidge, Inc. Revised: 15 -Jan -2016
r .
Constructional Data_;Report (CDR) '
'1 A Reference and Address". s r
Re ort Number
1o1s41132Lax-oo2:: ,' Original 22 -Ma -2014 Revised: 15 -Jan -2016
Brand name:..,,,
UL Subject 2703'Outline of Investigation for Rack Mounting Systems and Clamping Devices'
Standard(s)V
for Flat -Plate Photovoltaic Modules and Panels, Issue Number: 1, October 4, 2010
Applicant,
IronRidge, Inc.
Manufacturer.1
IronRidge, Inc.. '
`Address
1495 Zephyr Ave
.,Address
1495 Zephyr Ave "
-
_
Hayward, CA 94544
Hayward, CA 94544
countr
USA •. -
.,'Country,
USA
Contact''
Yann Schwarz
Contact . ' .
Jim Norsworthy Or
'1
The Grounding Mid Clamps are installed onto the module frame by using a 18-8 `stainless steel
=F ':
Dave Taggart
`.Phone
(800) 227-9523
f :Phone
(707) 363-3025
'
r
(510) 225-0973
`
(800) 227-9523
FAX
(707) 459-1833.
FAX .'
(510) 225-0975
Email `
yschwarz(a-iron ridge com
Email
Inorsworthy(t�ironridge.com
.
using stainless steel hex bolt or T -Bolt, flat washer, split lock washer, and nut, tightened to
dta artironrid e.com
Manufacturer 2
Precision Die & Stamping, Inc.
a
r
secured to XRL, XR10, XR100 or XR1000 Rail's side center cavity of rails using stainless steel
1704 W. 10th Street •
Address.
-
Tempe, AZ 85281'
-
"` • - ' '- , ' '
__Country"'
USA
Contact
Andy Frola
Phone
(480)967-2038
' FAX ; .
(480) 829-0838
(mail
andv aborecisiondie.com
2.0 Product Description
Product :
XR Rails with Integrated Grounding: .
Brand name:..,,,
IronRidge Roof Mount
w ",r
The product covered by this report is the IronRidge Rails with'Integrated Grounding solar roof
mounting system. This system is designed to provide bonding and grounding to photovoltaic
'
modules' The mounting system employs anodized aluminum rails that are roof mounted using
aluminum Extruded L Foot brackets. The mounting rails in this report are XRL, XR10, XFZ100
and XR1000 Rail. All rails have an optional aluminum splice which ties the rails together to
extend their lengtli. y• -
A grounding strap and stainless steel hardware are required for penetrating the anodized
r
coating of the rails,creating a bonded connection from -rail to rail. 304 stainless steel Grounding
Mid Clamp and aluminum End Clamps are used to attach and support framed photovoltaic
~•'
modules to the system. The End Clamps are not used as a grounding means.
'1
The Grounding Mid Clamps are installed onto the module frame by using a 18-8 `stainless steel
=F ':
serrated T -Bolt and a 18-8 stainless steel Flange Hex Nut that gets screwed onto the rails to a
Description '' "
specified torque. The retention teeth of the clamp and bolt.penetrate the anodized coating of
the photovoltaic modules frame and rail to contact the metal, creating a bonded connection
'
from module to module and module to rail.
-• T
The grounding of the entire system is intended to be in accordance with the latest edition of the
National Electrical Code, including NEC 250: Grounding and Bonding, and dNEC, 690: Solar
•'
Photovoltaic Systems. Any local electrical codes must be adhered in addition to the
tea."
national electrical codes. An entire array, regardless of size, is grounded via one grounding '
lug. The WEEB Grounding Lug is secured to XRL, XR10, XR100 or XR1000 Rail's top slot
using stainless steel hex bolt or T -Bolt, flat washer, split lock washer, and nut, tightened to
manufacture's specified torque. The WEEB Grounding Lug is intended for use with one solid or
rf
stranded copper wire, conductor size 14 AWG though 6 AWG. The Titan Grounding Lug is .
•
r
secured to XRL, XR10, XR100 or XR1000 Rail's side center cavity of rails using stainless steel
T -bolt, k -lock nut, star washer, and machine screw. The Titan Grounding Lug is intended for .'
use with one solid or stranded copper wire, conductor size 14 AWG though 4•AWG..
Models
IR XR followed by 4 Alphanumeric Characters
Model •Similarity
N/A `
Fuse Rating: 20 A -
'
Fire Class Resistance Rating:
Class A for Steep Slope Flush -Mount (Symmetrical) Applications when using Type 1,'
Type 2 and Type 3, Listed Photovoltaic Module. 1, ,
1''
�- Class A for Low Slope Flush -Mount (Symmetrical) Applications when using Type 1, -
Ratings a•
Type 2 and Type 3, Listed Photovoltaic Module.
Class A for Steep Slope Tilt -Mount ( Asymmetrical) Applications when using Type 1'=' '
and Type 2, Listed Photovoltaic Module.
-`Class A for Low Slope Tilt -Mount ( Asymmetrical) Applications when using Type -1, ,
Type 2 and Type 3, Listed Photovoltaic Module.
., r
• Page 1 of 86 `. Q ! s . .+ ' :' • .A
-
r This report is for the exUusive use of Intertek's Client and .is provided pursuant to the agreement between Intertek and Its Client Intertek's responsibility and * • - f °
f T f
liability are limited to the terms and conditions of the agreement Intertek assumes no liability to any party, other than to the Client in accordance with the w . :f r ' J♦ a
agreement, for any loss; expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and .
then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be
approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the
- `!• material, product, or service is or has ever been under an Intertek certification program. - , ' , •,„ ' ' • .. ' ' ' ED 16.3.15 OJan-13) Mandatory -
_
t
•
L
r
•4
• r.
r
4
.
• Page 1 of 86 `. Q ! s . .+ ' :' • .A
-
r This report is for the exUusive use of Intertek's Client and .is provided pursuant to the agreement between Intertek and Its Client Intertek's responsibility and * • - f °
f T f
liability are limited to the terms and conditions of the agreement Intertek assumes no liability to any party, other than to the Client in accordance with the w . :f r ' J♦ a
agreement, for any loss; expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and .
then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be
approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the
- `!• material, product, or service is or has ever been under an Intertek certification program. - , ' , •,„ ' ' • .. ' ' ' ED 16.3.15 OJan-13) Mandatory -
s
.ft ! • '
t 25800 Commercentre Drive
` Lake Forest, CA 92630 USA
R Telephone: 949.448A1 00
" Facsimile:`" 949.448.4111
wvvw.intertek.com
" Test Verification' of Conformity.
In the basis of'the tests undertaken, the samples) of the below product have been;found=to comply with the re quirements.of.
the referenced specifications at the time the tests were carried out: "
This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are'
limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense
or damdge occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its
marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results
referenced in this. Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been '
under an Intertek certification program. ,
GFT -OP -11a (24 -MAR -2014)
Applicant Name & Address:
IronRidge, Inc.'° .
1.495 Zephyr Ave.
Hayward�:CA 94544
Product Description:
XR Rails with Integrated Grounding.
Ratings & Principle
F.ire'Class.Resistance°Rating:
Characteristics:
- Class A for Steep Slope Flush-Mount,(symmetrical) Applications when using Type land: • L
L
Type 2Jisted Photovoltaic Module. '
Y
Class A for Low Slope Flush -Mount and Tilt -Mount (symmetrical and asymmetrical) `
Applications when using Type�1, Listed Photovoltaic, Module. a u'
'Models: ,..
51-61GD-005,°51-61GD-0056, 51=5000-001, and 51'-65-001 '•
.Brand Name.- . ; -
N/A
Relevant Standards:
UL Subject 2703 (Section 15.2 and 15.3) Outline of Investigation for Rack Mounting Systems and .
�.
Clamping. -Devices for Flat -Plate Photovoltaic Modules�and Panels, Issue Number: 2;.Nov 13; 2012
'
Referencing UL1703.(Section 31.2),Standard for Safety for Flat -Plate Photovoltaic Modules and „
Panels, May 20, 2014,
`, \
Intertek Testing Services NA Inc.y-
Verification-Issuing Office;
25800 Commercentre Dr: Y
Lake Forest, CA 92630 . r -
Date of Tests:.
08/27/2014 to.01/07/2015,
Test'Report Number(s): J
�101541132LAX=002
This verification is,part of the full test reports) and:should be` read in conju_ nction with them. This report does not automatically
imply product certification.
_•> �. " t
, '
, .' , ,
completed by: Amar Kacel Reviewed by: Andrew Koretoff
Title:, PV Engineer Title: Reviewer
Signature':
,
Date:'. = c Date: 01/26/2015
•01/26/2015
This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are'
limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense
or damdge occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its
marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results
referenced in this. Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been '
under an Intertek certification program. ,
GFT -OP -11a (24 -MAR -2014)
Carbon monoxide alarms required by Sections R315.1 and R315.2 shall be installed in the
following locations:
1. Outside of each separate dwelling unit sleeping area in the immediate vicinity of the
bedroom(s).
2. On every level of a dwelling unit including basements.
R315.1.5 Multiple -purpose alarms: Carbon monoxide alarms combined with smoke alarms
shall comply with Section R315, all applicable standards, and requirements for listing and
approval by the Office of the State Fire Marshal, for smoke alarms.
Butte County's Interpretation of 2016 CRC, Sections 314 & 315 for
Smoke Alarms & Carbon Monoxide Alarms:
Where alterations, repairs or additions exceeding $1,000 in valuation, existing dwellings shall be
retrofitted with smoke alarms and those that have attached garages or fuel -burning appliances shall have
carbon monoxide alarms installed. Existing smoke alarms can be replaced with dual function alarms for
Smoke and Carbon Monoxide and in most cases will comply with the aforementioned code requirements
for Carbon Monoxide Alarms.
DECLARATION OF INSTALLATION UNDER THE PENALTY OF PERJURY
As Owner/Contractor, I/we affirm and declare under the penalty of perjury, under the laws
of the State of California, by our signatures below as Owner/Contractor, that I/we will
comply prior to final inspection with Items A & B as specified herein:
i
A. Both Owner/Contractor have read and clearly understand the aforementioned 2016
California Residential Code (CRC) Carbon Monoxide Alarm requirements.
B. Both Owner/Contractor are responsible for installing Carbon Monoxide Alarms prior to
final inspection as per the aforementioned building code and maintaining such
installation. Smoke Alarms will also be installed prior to final inspection as per the 2016
CRC.
Smoke and Carbon Monoxide alarms are now installed in the following locations:
Owner's name (print): r ,A, �
Owner's signature: �il af� — Date: I T o� lI l
Contractor's name (print):/Peteda , CSLB License:
Contractor's signature:/ Date: 1' _
Project Address: Permit
Page 2 of 2
Revised 12.19.2016
Butte County Department of Development Services FORM NO
PERMIT CENTER
7 County Center Drive, Oroville, CA 95965 DBI -01
Main Phone (530) 538-7601 Fax (530) 538-7785
Nvx%,w.buuecountv.net/dds
Declaration of Installation
for Smoke Alarms and Carbon Monoxide Alarms
The newly adopted 2016 California Residential Code requires the installation of Carbon
Monoxide Detectors in dwelling units and in sleeping units within which fuel -burning appliances
are installed and in dwelling units that have attached garages. The policy for Carbon Monoxide
Alarms in Butte County states: "Any permit obtained in which the value of work exceeds $1000
associated with a Residential Group R Dwelling Unit or Sleeping Unit shall conform to the
following 2016 California Residential Code requirements for Smoke and Carbon Monoxide
Alarms (Section R314 & R315)."
2016 California Residential Code requirements for Carbon Monoxide Alarms:
R315.1 New construction: An approved carbon monoxide alarm shall be installed in dwelling
units and in sleeping units within which fuel -burning appliances are installed and in dwelling
units that have attached garages.
R315.1.2 Power supply: For new construction required carbon monoxide alarms shall receive
their primary power from the building wiring where such wiring is served from a commercial
source and shall be equipped with a battery back-up. Alarm wiring shall be directly connected to
the permanent building wiring without a disconnecting switch other than as required for over -
current protection.
Exceptions:
1. In dwelling units where there is no commercial power supply the carbon monoxide alarm may be solely
battery operated.
2. In existing dwelling units a carbon monoxide alarm is permitted to be solely battery operated where
repairs or alterations do not result in the removal of wall and ceiling finishes
or there is no access by means of attic, basement or crawl space.
R315.1.3 Interconnection. Where more than one carbon monoxide alarm is required to be
installed within the dwelling unit or within a sleeping unit the alarm shall be interconnected in a
manner that activation of one alarm shall activate all of the alarms in the individual unit.
V
Exception: _', r•i ^..,
1. Interconnection is not required in existing dwelling units where repairs do not result in the
removal of wall and ceilino finishes. there'is no access by means of attic. basement or crawl
` space, and no previous method for interconnection existed.
R315.2 Where required in existing dwellings: Where a permit is required for alterations,
repairs or additions exceeding one thousand dollars ($1,000), existing dwellings or sleeping
units that have attached garages or fuel -burning appliances shall be provided with a carbon
monoxide alarm in accordance with Section R315.1. Carbon monoxide alarms shall only be
required in the specific dwelling unit or sleeping unit for which the permit was obtained.
R315.2.6 Alarm requirements: No person shall install, market, distribute, offer for sale or sell
any carbon monoxide device in the State of California unless the device and instructions have
been approved and listed by the State Fire Marshal.
Page 1 of 2
Revised 12.19.2016