Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B18-0417 031-232-027
BUTTE COUNTY' DEPARTMENT OF DEVELOPMENT SERVICES INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspections is 3pm) Development Services cannot guarantee inspections on the date requested Office: 530.538.7601 Fax: 530.538.7785 www.ButteCountv.net/dds Permit No: B 18-0417 Issued: 2/22/2018 APN: 031-232-027 Address: 780 YUBA AVE, OROVILLE Owner: - MILLER BARBRA Permit Type: SOLAR ROOF -RES Description: ROOF MNT SOLAR (6.875 KW) AREA Flood Zone: SRA Area: SETBACKS for Zon*np- AG. SRA. PW Front: Centerline of Road: Rear: SRA: Street: AG: Interior Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING Inspection Type IVR INSP DATE Setbacks 131 Foundations / Footings 111 Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Signed Pre -Slab 124 'Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 Blockin nde inin 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed Shearwall/B.W.P.-Interior 134 Shearwall/B.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 417 Manometer Test Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed 0 I Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Plumbing Final 813 Fire Sprinkler Test or Final 702 Swimming Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 1 503 Pre -Plaster 1 507 Manufactured Homes Setbacks 131 Blockin nde inin 612 Tiedown/Soft Set System 611 Permanent Foundation S stem 613 Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Skirting/Steps/Landings 610 - Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: Length x Width: Insignia: UUM Permit Final 802 Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test or Final 702 Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final "PROJECT FINAL -rroject r mai is a t-ernncate of occupancy for (ttesiaennai unty) PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION 't PHOTOVOLTAIC -SYSTEM 1 P.V;SYSTEM SUMMARY: 6.875 KW • CITY NOTES:' SITE LOCATION AND HOUSE AERIAL VIEW INTERCONNECTION PV BREAKER TIED INTO MSP 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. • ' PV -2A - SITE LOCATION:. HOUSE AERIAL VIEW: PVA NON-COMPLIANT PLUMBING FIXTURES WITH WATER CONSERVING PLUMBING FIXTURES IN THIS PROJECT COMPLIES WITH THE FOLLOWING: 1 STRING WITH 13 MODULES AND 1 STRING WITH 12 ACCORDANCE WITH CGBSC ` ROOF MOUNT RESIDENTIAL PHOTOVOLTAIC SYSTEM 2016 CALIFORNIA BUILDING CODE (CBC) ' •`� 4 ► ' + = -�; ✓, ' SECTION301.1.1 AND CIVIL CODE 1101.1 AS FOLLOWS: - SYSTEM SIZE (DC) STC: 25 X 275= 6875W DC - ' 2016 CALIFORNIA, CODE (CEC) y , + 2016 CALIFORNIA FIRE CODE (CFC), - , . • ' :. PTC: 25 X 249.20 = 6230.00W DC 2016 CALIFORNIA PLUMBING CODE' 1 -SHOWER HEADS 2.5 GPM I '2016 CALIFORNIA MECHANICAL CODE "'. EMT CONDUITS ARE ATTACHED TO THE ROOF USING PRESSURE TREATED WOOD IN CASEf ' SYSTEM SIZE (CEC-AC) ° _ .25 X 249.20 X 98% = 6105.40W AC 2016 CALIFORNIA ENERGY CODE" r- _ MODULES ' 25 X CANADIAN SOLAR ALL BLACK CS6K-275M, 275W . 2016 CALIFORNIA RESIDENTIAL CODE - Tohemb.M* _ `w T'Ave. 2016 CALIFORNIA ADMINISTRATIVE CODE r Y t t 45: INVERTER SOLAR EDGE SE5000H-U6 AS ADOPTED BY CITY OF OROVILLE. R i'8i1I,y r fobs �11ork:C�t�, i ROOF COMPOSITION SHINGLE ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE r * `'-a •`Yl�S iv6iia MAXIMUM EXTENT POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TILT 27° PITCH TO THE SURFACE UPON WHICH THEY ARE MOUNTEDki ba Ave AZIMUTH 180° & 270° ' VISIBLE PORTIONS OF THE SOLAR PANEL SUPPORT STRUCTURE AND ANY EXPOSED ELECTRICAL CONDUITS, BOXES AND PANELS WILL NOT BE EXPOSED, AND WILL BE ; I . RAFTER/TRUSS SIZE 2" X 4" TRUSSES @ 24" O.0 'COLORED MATCHED TO EXISTING ROOF OR SURROUNDING HOME.___:, . -» ATTACHMENT TYPE FLUSH FOOT MOUNT WITH IRONRIDGE XR100 RAIL MODULES SHALL BE TESTED, LlSTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN a ACCORDANCE WITH UL 1703. THE FIRE CLASSIFICATION SHALL COMPLY WITH TABLE I ' EXISTING 125 AMPS MSP WITH 100 AMPS MAIN . - ' 1505.10F THE CALIFORNIA BUILDING CODE BASED ON THE TYPE OF CONSTRUCTION OF, MAIN SERVICE PANEL BREAKER ON TOP FEED - THE BUILDING CRC SECTION R9024 SITE LOCATION ' SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER CRC SECTION R314 AND SITE LOCATION AND HOUSE AERIAL VIEW INTERCONNECTION PV BREAKER TIED INTO MSP 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. • ' PV -2A OCPD RATING 30 AMPS •� - - '• RESIDENTIAL BUILDING UNDERGROUND ADDITION OR IMPROVEMENTS SHALL REPLACE , HOUSE AERIAL VIEW: PVA NON-COMPLIANT PLUMBING FIXTURES WITH WATER CONSERVING PLUMBING FIXTURES IN PV -5 1 STRING WITH 13 MODULES AND 1 STRING WITH 12 ACCORDANCE WITH CGBSC ` - STRINGING MODULES IN SERIES IN EACH STRING SECTION301.1.1 AND CIVIL CODE 1101.1 AS FOLLOWS: - M -WATER CLOSETS: 1.6 GPF (GPF= GALLONS PER FLUSH) UTILITY PACIFIC GAS AND ELECTRIC COMPANY (PGE) -FAUCETS (ALL INTERIOR) 2.2 ( GPM = GALLIONS PER MINUTE),,,,,.M --URINALS 1.0 GPF 1 -SHOWER HEADS 2.5 GPM I M .. "'. TABLE OF CONTENTS PV -1 SITE LOCATION AND HOUSE AERIAL VIEW PV -2 SITE PLAN PV -2A ROOF PLAN WITH MODULES LAYOUT'. ' PV -3 ELECTRICAL LINE DIAGRAM PVA ROOF MOUNTING. DETAILS, ELEC. CALCULATION & MATERIAL LIST ' • ' PV -5 LABELS' MODULE LOCATION 011111!-,r ' Ei�*+raic�v�u.r+� CLIENT: REVISIONS: TITLE: SHEET: ' t' DATE: , '02/20/81 j C-10#1029644 DESCRIPTION DATE REVISION Creed® u_ MILLER, BARBRA FOREVER 4 780 YUBA AVE, DESIGN SITE LOCATION AND FREEDOM FOREVER'LLC� .� OROVILLE, CA 95965 - BY: r, GREG PV -1 ' - (510) 688-6274 1.t HOUSE AERIAL VIEW 25819 Jefferson Ave, Murrieta, CA 92562 - , Tel: (888) 557-6431 , JOB NO.: FS -02 • • INSTALLATION NOTES: - . ` THE PV BREAKER SHALL NOT EXCEED 120% OF THE ALLOWABLE BACK FEED OF THE MAIN SERVICE BUSS RATING.O - PV WIRE SHALL BE USED ON DC RUNS FOR UNGROUNDED/TRANSFORMERLESSI INVERTERS. INSTALL CREW TO VERIFY ROOF STRUCTURE- PRIOR TO COMMENCING WORK. "'. EMT CONDUITS ARE ATTACHED TO THE ROOF USING PRESSURE TREATED WOOD IN CASEf ' w OF COMPOSITE ROOF OR COUNDUIT HANGERS IN CASE OF CONCRETE ROOF u MODULE LOCATION 011111!-,r ' Ei�*+raic�v�u.r+� CLIENT: REVISIONS: TITLE: SHEET: ' t' DATE: , '02/20/81 j C-10#1029644 DESCRIPTION DATE REVISION Creed® u_ MILLER, BARBRA FOREVER 4 780 YUBA AVE, DESIGN SITE LOCATION AND FREEDOM FOREVER'LLC� .� OROVILLE, CA 95965 - BY: r, GREG PV -1 ' - (510) 688-6274 1.t HOUSE AERIAL VIEW 25819 Jefferson Ave, Murrieta, CA 92562 - , Tel: (888) 557-6431 , JOB NO.: FS -02 • • ROOF AREA: 2207.85 SQ FT PROPERTY LINE 14'-10" y o ' ROOF LINE ' 33'-7" (N) 25 CANADIAN SOLAR ALL BLACK -275M, 275W CS6K I _ F— I HTfl- o fQ �U N 55'-6" co 4'-5" 49'-4" to , DRIVEWAY (E) MAIN SERVICE PANEL 25-7 67'-11" YUBA AVE r SITE PLAN 1 SCALE: 1/16 = V -0" „„n Electoral Comate Na CLIENT: REVISIONS: TITLE: SHEET: IC -10#1029644 MILLER, BARBRA DATE: 02/20/2018 freedoDESCRIPTION DATE REVISION F O R E V E R 780 YUBA AVE, DESIGN 725819 EEDOM FOREVER LLC . OROVILLE, CA 95965 BY: GREG SITE PLAN PV -2 Jefferson Ave, Murrieta, CA 92562 (510) 688-6274 _ JOB No.: FS -02-043 Tel: (888) 557-6431 .. . FIRE SETBACKS T TYI (N) 25 CANADIAN SOLAR ALL BLACK CS6K-275M, 275W Q(N) ATTACHMENT POINTS @ 72" O.C. MAX. f ROOF AREA STATEMENT ROOF MOQDTUYLES PITCH AZIMTUH ROOF AREA ARRAY AREA 1 18 270 180° 616.89 SQ FT 324.90 SQ FT 2 7 27a 270° 427.07 SQ FT 1 126.25 SQ FT NOTE: EMT CONDUIT SUPPORTED BY PIPE Q HANGERS 12" TO 18" AWAY FROM ROOF EDGE ATTACH CLAMP AT 25% FROM EDGE AND 50% FROM CENTER OF MODULES © JUNCTION BOX MOUNTED TO THE RAIL ` 1 LEGEND: ® CHIMNEY O PIPE VENT — — — — (N) JUNCTION BOX,& FIRE ACCESS POINTSMEN MSP AC IN ' . (E) MAIN SERVICE PANEL (N) SOLAR EDGE SE5000H-US INVERTER Q(N) 3/4" EMT (N) AC DISCONNECT CONDUIT ROOF PLAN WITH MODULES LAYOUT a 1 SCALE: 1/8"= V-0" .ElecMml C"madwNa CLIENT: -EREV - TITLE: SHEET: �( C-10#1029644 MILLER, BARBRA ON DATE REVISION DATE: 02/20/2018 ' ,freedom 780 YUBA AVE, DESIGN ROOF PLAN WITH FREEDOM FOREVER LLC - . OROVILLE, CA 95965 BY: GREG MODULES LAYOUT PV -2A 25819 Jefferson Ave, Murrieta, CA 92562 (510) 688-6274 Tel: (888) 557-6431 JOB NO.: FS -02-043 Max. OCPD: (125A Bus) * (1.2) = 150A Max Rating (120% of Bus) PV Backfeed (30A) + Main Breaker (100A) = (130A 5 150A) See 705.12 (D)(2)(3)(b) of 2016 CEC CTDIAI(`2_1 13 CANADIAN SOLAR ALL BLACK CS6K-275M, 275W I I I STRING -2 12 CANADIAN SOLAR ALL j BLACK CS6K-275M, 275W I I I I I I I I I I I I L-------------------- 2 - #10 AWG, PV WIRE 1 - #6 EGC, BARE COPPER (TYP.2) General Notes: SOLAREDGE P320 POWER OPTIMIZERS —2 - #10 AWG, PV WIRE 4 - #10 AWG, THWN-2 1 - #8 EGC, THWN-2 IN 3/4" EMT CONDUIT JUNCTION 1 4# BOX ------------- i4 ----- SOLAREDGE P320 POWER OPTIMIZERS 1. (25) CANADIAN SOLAR ALL BLACK CS6K-275M, 275W wired and listed to UL1703 standards INVERTER SOLAR EDGE S E5000H-US AC DC 2. SOLAR EDGE SE5000H-US Inverter with integrated DC Disconnect and Arc Fault Protection. Attached with system electrical specifications and ground fault protected & listed to UL1741 standards. 3. Photovoltaic system ground will be tied into existing ground at main service from DC Disconnect/Inverter as per CEC Sec. 250.166(A). "The Grounding Electrode Conductor shall not be smaller than the neutral conductor and not smaller than 8AWG copper." 4. Equipment operating 150 volts or greater shall only be serviced or replaced by qualified personnel. Field protection may be in the form of conduit, closed cabinet or an enclosure which requires use of tools to open. 5. Solar Photovoltaic System equipment will be installed in accordance with requirements of Art. 690 of the 2016 CEC. 6.Minimum height of conduit above roof to match temperature derating factor. 7.Photovoltaic DC conductors entering the building shall be installed in metallic raceway and shall be identified every 10 feet -- and within 1 foot above and below penetrations of roof/ceiling assemblies, walls, or barriers — with minimum 3/8 -inch -high white lettering on red background reading:"WARNING: PHOTOVOLTAIC POWER SOURCE" (N) DERATE 100A / 2P MAIN BREAKER RAPID SHUTDOWN SWITCH 30A, AC DISCONNECT 30A / 2P PV BREAKER ------- --- �o --— — — — — — — — — — — — — — — — — — — — — — — — — 3 - #10 AWG, THWN-2 1 - #10 EGC, THWN-2 IN 3/4" EMT CONDUIT THE GROUNDING ELECTRODE CONDUCTOR SHALL BE CONNECTED FROM THE ARRAY FRAME DIRECTLY TO A GROUNDING ELECTRODE (E) 125A MAIN UTILITY SERVICE PANEL METER n I• L---------------- - CONNECT TO EXISTING UFER 8. System Grounding Electrode conductor for PV system to be sized to meet the requirements of CEC 2016 table 250.66, not smaller than #8 CU AWG." 9. If the existing main service panel does not have a ground rod or ufer, it is the pv contractors responsibility install one. 10. Smoke alarms and carbon monoxide detectors will meet the necessary requirements per CRC R314, R315 11. UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM. 12.Terminals of the disconnecting means may be energized in the open position. 13. A signage labeled "SOLAR LOADS ONLY" is to be installed on dedicated solar sub panel to be used for PV only. 14. Solaredge inverters are listed to UL1741 and UL1699B standards. 15. Solaredge Optimizers are listed to IEC62109-1 (class II safety) and UL1 741. standards. 16. PV system is using continuous grounding method with #6 bare copper wire. El-timl CoWWWNa CLIENT: , REVISIONS: TITLE: SHEET: C-10#1029644 MILLER, BARBRA DATE: O2/2O/2018 freedo'm DESCRIPTION DATE REVISION , F o e E V E a 780 YUBA AVE, DESIGN GREG ELECTRICAL PV -3 FREEDOM FOREVER LLC _ OROVILLE, CA 95965 BY: LINE DIAGRAM 25819 Jefferson Ave, Murrieta, CA 92562 (510) 688-6274 Tel: (888) 557-6431 JOB NO.: FS -02-043 PV MODULE, BY OTHERS IRONRIDGE RAIL (E) ROOF MEMBRANE IRONRIDGE FLASHFOOT2 ` (E) BUILDING STRUCTURE ELECTRI CAL 'CALCU LATI ONS PV MODULE, BY OTHERS BACKFEED BREAKER SIZING IRONRIDGE MAX. CONTINUOS OUTPUT 21A @ 240V RAIL (E) ROOF 21 X 1.25 = 26.25AMPS 30A BREAKER - OK MEMBRANE CEC 705.12 (D) (2) (3) (b) IRONRIDGE FLASHFOOT2 125 X 1.20 = 150.1 150 - 100 = 50A ALLOWABLE BACKFEED ,. (E) BUILDING STRUCTURE DE -RATED AMPACITY OF 8 AWG CONDUCTOR @ 0.87 TEMPERATURE CORRECTION 55 X 0.87 = 47.85 AMPS - OK Existing composition shingle roof End Clamp Photovoltaic Module 5/16" diameter 3.5" length lag screw Mid Clamp MATERIAL LIST QTY EQUIPMENT DESCRIPTION CANADIAN OPEN CIRCUIT VOLTAGE (Voc) : 38.3V SOLAR ALL MAX. POWER VOLTAGE (Vmp) : 31.3V 25 BLACK SHORT CIRCUIT CURRENT (Isc) : 9.31A CS6K-275M, MAX. POWER CURRENT (imp): 8.80A 275W PTC RATING: 249.2W SOLAR EDGE MAX. DC INPUT VOLTAGE: 350V SE5000H-US MAX. AC OUTPUT VOLTAGE RANGE: 211-240V 1 MAX. AC OUTPUT CURRENT: 21A WITH POWER MAX. AC POWER OUPUT : 5000W OPTIMIZER CEC EFFICIENCY: 98% 1 JUNCTION BOX 60oVDC, NEMA 4X, UL LISTED 1 AC DISCONNECT 600VAC, 30A, NEMA 3R, UL LISTED 1 PV BREAKER 2 POLE, 240V, 30A 34 ATTACHMENTS FLUSH FOOT MOUNT 142' RAIL IRONRIDGE XR100 IRONRIDGE XR100 GROUNDING 44 MID CLAMPS MID CLAMPS 12 END CLAMPS IRONRIDGE XR100 END CLAMPS 40' CONDUIT 3/4" EMT CONDUIT 1 MAIN BREAKER 2 POLE, 240V, 100A Existing 2" X 4" 6"max TRUSSES @ 24" O.0 IronRidge per PV Support "Mininum 2.5" Lag Screw Embedment Photovoltaic Panel Mounting Detail Scale: NTS R.f� Electrlc"ICo�eCuNa CLIENT: F ` REVISIONS: TITLE: SHEET: freedom c-10#1o29s44 MILLER, BARBRA DATE: 02/20/2018 DESCRIPTION DATE REVISION ROOF MOUNTING F,O R"E v.E R 780YUBAAVE, DESIGN GREG DETAILS, ELEC. PV -4 FREEDOM FOREVER LLC OROVILLE, CA 95965 BY: CALCULATION & 25819 Jefferson Ave, Murrieta, CA 92562 (510) 688-6274 MATERIAL LIST Tel: (888) 557-6431 - JOB "No.: FS -02-043 LABELS: LABELS SPECIFICATION: 1. ALL CAPITAL LETTERS 2. MINIMUM 3/8" LETTER HEIGHT 3. ARIAL OR SIMILAR, NON -BOLD 4. WHITE LETTERING IN RED RATED A£ OUTPUT CURRMT•- 30 A -WS A£ BACKGROUND 5. WEATHER RESISTANT MATERIAL r SUITABLE FOR THE ENVIRONMENT CEC 690.55414 CEC 705.12(D)(3) (DURABLE ADHESIVE MATERIALS MUST MEET THIS REQUIREMENT 6. ALL SIGNS SHOULD BE REFLECTIVE CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING Q WARNING SOURCES WITH DISCONNECTS LOCATED AS SHOWN TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL ' CA Electrical Code (CEC) ARticles 690 and 705 and CA Residential Code (CRC) SecUon 8331 require the following labels or markings be installedat these components of the photovoltaic system: WA.RNMNG WARNTING DUAL POWER SOURCES INVERTER OUTPUT CONNECTION;MJ SECOND SOURCE 1S PROTOt OLTAIEC SYSTO s DO NOT RELOCATE THIS a ,,moo RATED A£ OUTPUT CURRMT•- 30 A -WS A£ OVERCURRENT DEVICE. NORMAL OPERATYAG VOLTAGE 240VOLTS r CEC 705.11(D)(2)(3)(b) CEC 690.55414 CEC 705.12(D)(3) lNot required if panelboard is rated not less than sum of ampere ratings of all overeurrent devices supplying it] PST SYSTEM AC DISCONNECT • RATED AC OUTPUT CURRENT - 30 A&M A AC NORMAL OPERATING VOLTAGE 240 '%TOLTS W ARI-gA C DO NOT TOUCH TERMINALS 'k ELECTRIC SHOCK HAZARD. THE DC CEC 690.54 CO\7DUCTORS OF THLS PHOTOVOLTAIC " SYSTEM ARE UTGROUINDED ANBD ALAY @ "'...... '" WARI\'WG r BE ENERGIZEED ELECTRIC SHOCK HAZARD CEC 690350 IF A GROUND FAULT IS INDICATED, [Only required for ungrounded systems] ii INVERTER NORMALLY GROUNDED CONDUCTORS i -- Al AV BEUNGROUNDED AND ENERGIZED CEC 6905(C) •F1• •I ••w•••••••. [Normally already present on listed inverters] • • • - + WARNN G r I ELECTRIC SHOCK HAZARD CEC 690.31(G)(3) I I DO NOT TOUCH TERMINALS [Marked on junction/combiner boxes I TERMffiVALS ON BOTH LINE AND LOAD _ o and conduit every 10'J I E SIDES AIRY BE EI\ERGIZED IN THE OPEN POSITION C CEC 69117(E) o - JBox PV SYSTEM DC DISCON 'ECT R ATED DIAX POWER -POINT CLf-RREN'T- 13.5 C 25 PV MODULE RATED M3AX POW7ER POhN-T � OLTAGE- 350VDC MAXMfUM CIRCUIT CURRENT- 15 ADC MAXIMUM S1757TAI VOLTAGE- 480%IDC � JUNCTION BOX CEC 690.53 .. MIARN�G: MAIN SERVICE PANEL INVERTER EQUIPPED WITH TM EQUIPM N -r FED BY AIULTRLE SOURCES. • ,• • • • • 1' RAPID SHUTDOWN TOTAL RAMG OF ALL OVERCURR�T DEVICES, t� • AC DISCONNECT _ EXCLUDING MAIN SUPPLY OVERCURREN T DEVICE, SHALL N OT EMCEED AMPA= OF BUSBAR CEC 69056(C) [Required at location approved by AHd] ' YUBA AVE CEC 70512(I1)(2)(3)(c) [Required on new load center if answered "No" to Step S21] • Informational note: ANSI Z535.4 provides guidelines for the design of safety signs and labels for application to products. A phenolic plaque with contrasting colors between the text and background would meet the intent of the code for permanency. No type size is specified, but 20 point (3/8") should be considered the minimum CEC 705.11 requires a permanent plaque or directory denoting all electric power sources on or in the premises and the rapid shutdown initiatiou device. IWW� CLIENT: REVISIONS: DATE: 02/20/2018. TITLE: SHEET: [� .�freed %J9 I C-10#1029644 MILLER, BARBRA DESCRIPTION DATE REVISION U - 780 YUBA AVE, DESIGN GREG - LABELS PV -5 FREEDOM FOREVER LLC : OROVILLE, CA 95965 BY: (510) 688-6274 25819 Jefferson Ave, Murrieta, CA 92562 Jol3 No.: FS -02-043 Tel: (888) 557-6431 ` � • ' ALL C56K-280M / I-V,CURVES �r Can_ adianSolar c •' " ENGINEERING DRAWING (mm) t ! -BLACK �.. Frame Cross Section A -A �r A' , • A ' Rear View ,t _ • ' ' • - i -.._��. y.•{ " wN ♦ - 'r. •• 8-14x9, , Mounting t.. . - t L 1. Hole 1 0, l �y 4 .5 a . 4 d - - 5 . `•^.4_�,4^r.-" ' 4. J y iSS Mounting Hole.. >_ .• , '^-- 1' 7� w` - r. - i '�•� `< -^9 - 5 X10 •,5 20 25' 30 •35 40 + 5 10 15 2'25 30 35 40 1. •, - }'A1, ° { i4E Grounding �I -' rL_ _ 1000ww7, 5•c ■. • - - _ I _ Hole J r: a u■ ■ 800 W/m'• ',f�+k, ,y •t.•, 25•C ■ t + -„ :j ^ s ..... .`.' •+ i lr. :.. "'- ''• i• ■ 600 W/m' '.a - 45'C ■ , , 941 .-Yi 4W/m 65c . . 00 - r � ALL" -BLACK • 'ate _ -40 992. : 1 CS6 K-270 1 275 1 280 M 4 ' .-+,'"" ELECTRICAL DATA STC* MECHANICAL DATA • Y ±, • ` °~ I. All -Black CS6K 270M 27SM 280M Specification ` Data ' Canadian Solar's ALL -BLACK CS6K-M modules are -• ; t ,�" Y " Nominal Max. Power (Pmax) 270 W 275 W 280 W Cell Type ` Mono -crystalline, 6 inch equipped with dark mono -crystalline cells, a dark :, Opt. Operating Voltage (Vmp) 31.1 V 313 V 31.5 V Cell Arrangement 60 (6 It 10) colored backsheet and a black frame for�enhanced .. � '15* r y ^' I ' s Opt: Operating Current (Imp) 8.67 A' 8.80 A 8.89 A ,.Dimensions 1650x992x4O mm (65.0x39.1x1.57 in) aesthetics and reliable output. This product can • " 3�t � ;' _ . , r ",• - Open Circuit Voltage (Voc) 38.2 V- 38.3 V 38.5 V f , . Weight 18.2 kg (40.1 lbs) improve the aesthetics of a rooftop. tfE1 f ,+ f'�3>L " Short Circuit Current (Isc)'• . 9.19 A 9.31 A . 9.43 A Front Cover 3.2 mm tempered glass Module ' 16.50% 16.80% •17.11% E Frame Material Anodized aluminium alloy. ` +' Operating Temperature -40°C - +85"C. J -Box I1367, 3 diodes KEY FEATURES 25 linear power output warrantyF Max. System Voltage 1000 V (IEC) or 1000V (UL) . Cable 4 mm2 (IEC) or4 mm2 & 12 AWG „ Module Fire Performance TYPE 1 (UL 1703) or 1000V(UQ,1000 mm (39.4 in) l CLASS C (IEC 61730) • Connectors T4 series or PV2 series .. Excellent module efficiency of O 4 Max. Series Fuse Rating 15A' ' _ Per Pallet 26 pieces, 520 kg (1146.4 lbs) r c '. up to 17.11% 10 product warranty on materials a _ Application Classification Class A Per Container (4(HQ) 728 pieces f years and workmanship r ' r Outstanding low irradiance . + , -. : � Power Tolerance 0 -5W - - ................... ...... ' - .....: - , +;y j -Under Standard Test Conditions (S7 Q of irradiance of 1000W/ ', spectrum AM performance of up to 96.5%8 .................................:.........•. :a..� 1.5 and cell temperature ofzs c MANAGEMENT SYSTEM CERTIFICATES * •; , TEMPERATURE CHARACTERISTICS,' • , ISO 9001:2008 / Quality management system a ELECTRICAL DATA I NOCT* • •` t Specification + Data IP67 junction box for long-term '.. ISO 14001:2004 / Standards for environmental System management ` g tem r ,' All -Black C56K r 270M 27SM •'' 280M Temperature Coefficient (Pmak) -0.41 % /°C t +.weather endurance OHSAS 18001:2007 / International standards for occupational health and safety - . - ` . Nominal Max. Power (Pmax) 195W 199 W 202 W Temperature Coefficient (Voc) ' -0.31 % / oC F ` L Opt. Operating Voltage (Vmp) 28.4 V 28.5 V 28.7 V Temperature Coefficient (Isc) 0.053 % /"C r **4,Heavy snow load up to 6000 Pa,' CERTIFICATES* PRODUCT CERTIFICATES* 4+ Opt. Operating Current (Imp) - 6.87 A f 6.95 A ,7.04 A. Nominal Operating Cell Temperature 45±2 °C wind load up to 4000 Pa * IEC 61215 / IEC 61730: VDE / CE /MCS / CEC AU ' . Open Circuit Voltage (Voc) 35.0 V 35.1 V 35.3 V r , r x ` UL 1703 / IEC 61215 performance: CEC listed (US) • C`- r a Short Circuit Current (Isc) 7.44 A . 7.54 A 7.63 A Y .a. • ' �'- ` '- - - -• UL 1703: CSA _ . •ti " r • %r • ' + ,� }. .- �., _ + Under Nominal Operating Cell Temperature (NOCT), Irradiance of 800 W/m°, r. - ° ,,._�• _ .. * r , ' • Take -e -way .t +i Fr ,� • + 1 * 'Yy • , spectrum AM 1.5, ambient temperature 20°C, wind speed 1 m/s' ' + r t I a� - '+ , 'tom ° " ' ' ' •" 4 �. .. - C M� i o j' tear `' BBAV d/e �e� - rt - ' •.- G�• ,• PERFORMANCE AT LOW IRRADIANCE '.a _ - PARTNER SECTION e a r , " .. a , . , t CS�us\ ..�. _. ..• �. iat low irradiance, with an Outstanding performance a r Ir.. ,...... _.. ........... • ` -` x '' - �' •' i • - -As there are different certification requirements indifferent markets, -please contatt 4 average relative efficiency of 96.5 % from irradiances, ' '• - ;, your local Canadian Solar sales representative for the specific certificates applicable to the products In the region in which the products are to be used. .. _ -- ••: ` - - , ,_ - between 1000 W/m2 and 200 W/m2 (AM 1.5, 25'C).' ` * -'ti f �(' • �',' -, - ' - ' .. -' ' -............................................................................................... ....................... CANADIAN SOLAR INC. is committed to providinghigh quality a; '• � • � '� , • "- q H } r +' ' � ' � r :P s specification and k features described in this datasheet may deviate sli ht ear y 9 N • + 1.1 �•� ' e f �< � • i � ' "` .. �. •� solar products, solar system solutions and services to customers, .. , and are not guaranteed. Due to ongoing Innovation, research and product • r • - + ,,, ' / '� + E M • •enhancement , - Canadian Solar Inc. reserves the right to make any adjustment ,• + - •, , F.x. c ` • ' around the world. As a leading PV project developer and _ to the information described herein at anytime without notice. Please always ' ''' ` ' , fi, _ + - a ' _ `t .. _ r • , i manufacturer of solar modules with over 17 GW deployed around-, • ,• - obtain the most recent version of the datasheet which shall be duly incorporated N into the binding contract made by the parties governing all transactions related + ., • 4. •h - , the world since 2001, Canadian Solar Inc. (NASDAQ: CSIQ) is one of ^ ' • to the purchase and sale of the products described herein. _ ' • the most bankable solar companies worldwide.,- + + .Caution: For professional use on The Installation and handiin of PV modules P y g " u f t • t• a, `�+•, ` • ° ' •, ti r _ • . , requires professional skills and should only be performed by qualified professionals. * _ Please read the safety and Installation Instructions before using the modules. t - ..... .... .:.. ...... ..................................................... • ,. + • , +ror detail Information, please refer to Installation Manual. •' ,,, ' _ - _ ` '• '� - .." - , �'' 1 w " Y't 'r 4-............ ... .- .. Y ` • .> - ......................:.........:............:.................. -......................................................., CANADIAN SOLAR '. ....................... ....................... ..... ..... ......... , � ....................................................................................... .. _ CANADIAN OLAR INC. Dec. 2016. All rights reserved, C IAN S ................... .......................... ......... . .,. - . r Module Product Datasheet V5.531 EN r •1 INC. • g - 545 Speedvale Avenue West, Guelph; Ontario N1 K 1 E6, Can_ ada, www.canadiansolar.com,,support@canadiensolar.comR T ` � <, •• " , '; f + * , ` , +. +� s solar ' • • Single Phase Inverters 'for North America solar - SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE760OH-US _ SolarEdge Single Phase Inverters - I SE3000H-US SE380OH-US SESOOOH US I SE6000H-US SE7600H-US r I OUTPUTS P f O r North AmeriCa Rated AC Power Output 3000 3800 ,.' 5000 6000 7600 VA '•+� .. ....... ....... ....... ' • Max_ AC Power Output 3000 3800 5000 - 6000 7600 VA SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / (183.........w............................................................................................................. \ AC Output Voltage Min: Nom. Max. (183 - 208. 229) ✓ . Vac S E / 6OO H - U S AC Output Voltage Min. Nom: Max. (211 - 240 - 264) ✓ ✓ ✓ ✓ ✓ ,: • Vac AC Frequency (Nominal) t 59.3 - 60 - 60.51i1 Hz ........................................................... ................... .. Maximum Continuous Output Current 208V 24 ....... I - i - . .. .................... A Maximum Continuous Output Current 240V 125 16 21 25 32 A ................... ................... ................... ............. GFDI Threshold 1 A .............................................................................................'............................:................................ Utility Monitoring, Islanding Protection, I Yes Country Configurable Thresholds IINPUT ) Maximum DC Power 4650 5900 7750 9300 11800 W ' .............................................................................. I ..... .......... y. ... .. .. .. . r Transformer -less. Ungrounded - Yes 25 ; s............................................................................ m v2ars., Maximum Input Voltage 480 .............. Vdc .... .................................................. ....... .. .... Nominal DC Input Voltage 380 400 Vdc ...9min .l DCI .putt .................................... ................... ................... ................... Maximum Input Current 208V 15.5 Adc .................................... ................... Maximum Input Current 240V 8.5 10.5 13.5 16.5 I 20 Adc ............................................ ................... ................... ................... ................... 4 - Max. Input Short Circuit Current 45 ............................................... ..Adc..... Reverse -Polarity Protection Yes r,.................................................................................................... .................................. Ground -Fault Isolation Detection 600ko Sensitivity .............................. ................... • Maximum Inverter Efficiency 99 f 99.2 ...........................................................................I.".............................................................. .... .......... ...... ......... Weighted Efficiency99 % .............................................................. ....................................................................... ........ Nighttime Power Consumption < 2.5 W O '.SELF-SUSTAINING POWER OUTLET (OPTIONAL) ! Nominal Output Voltage.................................................120 V 9 Maximum Output Power ........... 1500111........ W...... ........................................................... ................................................... External Outlet with GFDI r Yes ` ADDITIONAL FEATURES Supported Communication Interfaces R5485, Ethernet, ZigBee (optional), Cellular (optional) ,,• Internal RGM supportANSI C12 20 class 0.5 compliant 9 Rapid Shutdown - NEC 2014 690.12 Automatic Rapid Shutdown, - i STANDARD COMPLIANCE Safety UL1741, UL1699B, CSA.22.2, Canadian AFCI according to T.I.L. M-07 ............................................................... ............. Grid Connection StandardsIEEE1547, Rule 21, Rule14 (HI) ........................................................................................................................................................ ............. Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS Optimized installation with HD -Wave technology _ _ - Record-breaking efficiency . Integrated arc fault protection for NEC 2011 690.11 and integrated rapid shutdown for NEC 2014 690412 Extremely smal High reliability without any electrolytic capacitors 17'D Built-in module -level monitoring — Outdoor and indoor installation wave — Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) — Optional: Self -Sustaining Power - produce up to 1.5kW directly from PV during grid failure USA-CANADA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THENETHERLANDS-UK-ISRAEL-TURKEY-SOUTH AFRICA -BULGARIA www.solaredge.us . - ' •�` M - AC Output Conduit Size / AWG Range DC Input Conduit Size / q of Strings /AWG Range Dimensions with Safety Switch (HxWxD) ..................................................... Weight with Safety Switch ........................................................... Noise Cooling Operating Temperature Range ........................................................... Protection Rating ........................................................... 111 For other regional settings please contact SolarEdge support 1�1 Depends an PV wallability 131 Power de -rating from 50•C solar-.. Solaff,dge Power'Optim"izer Module Add. -On For North America P300 P320 /'P400 P405 S.01ar =@9 'SolarEdge Power Optimizer t Module Add On for Ndrth America 4. P300 P320 P400 P405 A, 4, P300 (for 60 -cell modules) P320 (for high-power 60 -cell module' S) I 400 ,(for 72 & 96 -cell �� , , p modules) P405 (for thin film modules) "t ........................ . . ........ 7-1 .......... . ........................ 48 80 125 ......... Vdc (Voc at lowest temperature) .. ... ...... I ........................... .............. 4, Rated Inpyt.D.C.Powe r!'? 300 405 W ................ Absolute Maximum Input Voltage ........................ . . ........ 7-1 .......... . ........................ 48 80 125 ......... Vdc (Voc at lowest temperature) .. ... ...... I ........................... .............. ........................ '` MPPT Operating Range ...................... ......... ........... ............ .......... 8-48 8-80 . -,...12.5-105 Vdc ' FJ, ; I .... .. Maximum Short Circuit CLirrent (Isc) ; ... 11 10.1 I . 10 *�� ...................... ... Ad" - ;� ....... ..... . ......*"*"*"* ............ *"** .... * ... Maximum DC Input Current - ' .. ............................................ .......... I ................. : �.:.: ........ .12:5 ........ �... - '13.75 12.63 . . ........ I ...... . .............. ;� .. ...... ........................... I ....................... ; .... �.•L. I Adc .............. , - I t. . 99.5 : %.. ..11�imum.Efficiency ....... ............................... Weighted .F!fici ni;y ..................... ......... I ............................ ....................... ........ ................................... 98.8 .............. .................. .. ........... ...................................... ................. ...... .... ...... :Overvoltage Category. . OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) — Maximum Output Adc .............. . .7 .Maximum Output Voltage60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power. Vdc Optimizer STANDARD COMPLIANCE FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 _! ................ .... .............. ....................................... Safety ............................ ............................................................. I IEC62109-1 (class 11 s fe ), UL1741 ...... .............................. ................. .......................•....................... ....... RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System1000 ................ . ........... ... ........................... .. ... . ........................................................ ....... T' Vdc .......... 4. : Compatible inverters .............................. All SolalEdg�ngle Phase and Three Phase inverters ..................................... .......... ... 128 x 152 x 27.5 128 xiS�'X* 128xl52x5O/ m m n Dimensions (W x L x H) ............... 5 x 5.97 x 1�08 5 x 5.9, . ,,, - 5 x 5.97 x ......... . ........... .......... .1...7 .............................................. Weight (including cables) ............. .. ............ ...... .. ............................................ .......... 75"1 j 630/1.4 ....... .0 845/1.9 ......................... ....................... .............. ........ .................. ...gr lb .......... Input.... . ..................................... : ................................... ! .......... ................................... Output Wire TyRe/.Cqqpectqr ..... . ...... ......... Double Insulated; MC4.Compob!e.., ............... ....................................................... ................... ...... ... . Output tpy . ...... ............. .... ........ 0.95/3.0 1.2/3.9 . ......... ............................ ............. ........... a ........................................... M/ft .............. �Png Tpe�ure.Range ........ : : I 40 - +85 / -40 -'+185 .............................................................................................. ................ 'C/'F .............. Protection IP68 / NEMA6P . ............................................................... ............... ..... ............ ..R.elaty��yTicity .... 0 - 100 . .. ................................................................................ .%. .... 41 Rated STC power of the module. Module of up to +5% power tolerance allowed. PV SYSTEM DESIGN USING SINGLE PHASE •THREE PHASE 208VI • THREE PHASE 480V A SOLAREDGE INVERTER") Minimum String Length �0 - (Power Optimizers) .................. . ........... ..... .... : ............. .... .............. .... .................................... ................ Maximum String Length PV power optimization at the module level 25 25 c_50 (Power Optimizers) ... .... ........... .................. .................................... ........................ ........... ................................. .............. 6000 12750 W. — Up to 25% more energy Maximum.Power.p��5�Ting .. 5250 .............. ....... .. ......... .... 7 ....... ....................... ..................... ........ * ..... ................. : .................... ....... Parallel Strings of Different Lengths — Superior efficiency (99.5%) Yes or Orientations ........................................................... . ..... . ....... — Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading .. ................... ...................... .......................:: ............ It is not allowed to mix P405 with P300/P400/P600/P700 in one string. — Flexible system design for maximum space utilization 7, — Fast installation with a single bolt 77 7 — Next generation maintenance with module -level monitoring — Module -level voltage shutdown for installer and firefighter safety USA!C"ANADA- GERMANY- ITALY,- FRANCE -JAPAN -CHINA -AUSTRALIA -THE NETHERLANDS- UK- ISRAEL - TURKEY.'SOUTH AFRICA -BULGARIA www.solaredge.us tq* j.4 4 � , r _ ` ... - ',- -? •1�G'{L'C3a7.-7C�S v e Y � .. _ Y '- a. . - • � ' � ...'•-+a:++�aw+aa /fid IRONRIDGE ; :� +- Flush'~Mount'System a' XR Ra�lso - XR10 Rail ±r. -, Alow-profile mounting ra for regions with light sno% {" L - 6' spanning capability • Moderate load capabili Clear & black anod. fin Clamps &'Groundin XR1000 Rail _ Bonded Splices ' 1 • tw ' A heavyweight mounting 3 All rails use internal splices rail for commercial projects. for seamless connections.w- 4' • 12' spanning capability -'•• • Self -drilling screws , • Extreme load capability Varying versions for rails • ,Clear anodized finish Forms secure bonding + _ - +. ~- _ UFOs Stopper Sleeves Grounding Lugs" Microinverter Kits Universal Fastening Objects , Snap onto the UFO to turn :Connect arrays to Mount MIs or POs to XR r bond modules to rails. into a bonded end clamp: equipment ground. s Rails. T " Fully assembled & lubed • Bonds modules to rails Low profile - . Bonds devices to rails Single, universal size • 6 different sizes. Single tool installation • -Kit comes assembled • Clear & black finish _ • Clear & black anod: finish ' • Mounts in any direction • Listed to UL 2703 Built for solar's toughest roofs. Attachments & IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to a r the limit and proven in extreme environments . _ Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully"certified, code compliant and backed by a 20 -year warranty. x - Strength Tested s. PE Certified All components evaluated for superior Pre -stamped engineering letters , structural performance.. - •� available in most states. s IL Class'A Fire Rating t 1� Design Assistantf�'; 1 Certified to maintain the fire resistance Online software makes it simple to f Slotted L-Feet+Bonding Hardware '';� Flush Standoffs + t —� 111 Drop-in design for rapid rail :, Bond aria attach XR Rails. -Raise Flush Mount System attachment. ` , to certified attachments. , to various heights • Secure rail connections _T &Square Bolt options ""'� Works with vent flashing ` • Slot for vertical adjusting Nut uses 7/16" socket:: 4" and 7"aengths, `' � •Clear & black anod. finish; Assembled `& lubricated Ships assembled t - �•� Resources , ,, t i . , ` x�.N � , , ., - -- y • rating of the existing roof.. l" create, share, and price projects. • .. ,,x � ,, - ' ; �, .,' ._• _- _- Design Assistant UL 2703 Listed System - ` ' ;'20 -Year Warranty .Y �r _ – - Go from rough layout to fully Y 4- ' engineered system. For free. r ® Entire system and, components meet' Twice the protection offered by - + a _ Go to IronRidge.com/design , newest effective'UL 2703 standard. -;: _ competitors. • li, . ',t - �• S . .. � � \ .#', . . � � .r �• - � - .ti 2 �• - !. • `fit. t: �' '•^i. '� ,,�• - .+ti _ - y ' o -r• , � • Report No. 101541132LAX-002 Page 2 of 86 Issued: 22 -May -2014 _ CLASSIFICATION IronRidge, Inc. Revised: 15 -Jan -2016 Constructional Data Report (CDR) 1:0 Reference and -Address', Re ort.Number'' 101541132LAX-002 Original 22 -May -2014 Revised: 15 -Jan -2016 Brand name _ UL Subject 2703 Outline of Investigation for Rack Mounting Systems and Clamping Devices Standard(s) for Flat -Plate Photovoltaic Modules and Panels, Issue Number: 1, October 4, 2010 The product covered by this report is the IronRidge'Rails with Integrated Grounding solar roof Applicant; IronRidge, Inc. Manufacturer`1<: IronRidge, Inc. 1495 Zephyr Ave .' `- 9 ,`; 1495 Zephyr Ave Address:1' Hayward, CA 94544 ;Address ,• Hayward, CA 94544 Ha yw Count:. ' USA - Count USA Cont ct;'-. Yarn Schwarz `".Contact 'Jim Norsworthy Or ' ° Dave Taggart �� Phone ii. ' ; (800) 227-9523 �q Phone ' " (707) 363-3025 (510) 225-0973 (800) 227-9523 :FAX ` ` (707) 459-1833 }, FAX ". 510 225-0975 -,` " Finall - yschwarz(@ironridge.com =inorsworthy(a�ironridge.com Email y Photovoltaic Systems. Any local electrical codes must be adhered in addition to the national electrical codes. An entire array, regardless of size, is grounded via one grounding - . dta art ironrid e.com Manufacturer.2; Precision Die S Stamping, Inc. .} . %"= 7 � `Address 1704 W. 10th Street - Tempe, AZ 85281 secured to XRL, XR10, XR 100 or XR 1000 Rail's side center cavity of rails using stainless steel _'Country'_T;g. USA ' Contact ' . Andy Frola :Phone (480) 967-2038 Models _ '_':.' IR XR followed by 4 Alphanumeric Characters ` "=,FAX .y_-; "; 480 829-0838 Email' ,;: andv(5)precisiondie.com Fire Class Resistance Rating: Class A for Steep Slope Flush -Mount (Symmetrical) Applications when using Type 1, ` .. • '-. tom.. .. 4 Brand name _ IronRidge Roof Mount The product covered by this report is the IronRidge'Rails with Integrated Grounding solar roof mounting system. This system is designed to provide bonding and grounding to photovoltaic modules. The mounting system employs anodized aluminum rails that are roof mounted using aluminum Extruded L Foot brackets. The mounting rails in this report are XRL, XR10, XR100 and XR1000 Rail. All rails have an optional aluminum splice which ties the rails together to Yr extend their length. x �' fw "f „ u A grounding strap and stainless steel hardware are required for penetrating the anodized coating of the rails, creating a bonded connection from rail to rail. 304 stainless steel Grounding Mid Clamp and aluminum End Clamps. are used to attach and support framed photovoltaic t. .. • '-. tom.. .. 4 Brand name _ IronRidge Roof Mount 2.0 Product Description `u Product ::,: XR Rails with Integrated Grounding. Brand name _ IronRidge Roof Mount The product covered by this report is the IronRidge'Rails with Integrated Grounding solar roof mounting system. This system is designed to provide bonding and grounding to photovoltaic modules. The mounting system employs anodized aluminum rails that are roof mounted using aluminum Extruded L Foot brackets. The mounting rails in this report are XRL, XR10, XR100 and XR1000 Rail. All rails have an optional aluminum splice which ties the rails together to Yr extend their length. x �' fw "f „ u A grounding strap and stainless steel hardware are required for penetrating the anodized coating of the rails, creating a bonded connection from rail to rail. 304 stainless steel Grounding Mid Clamp and aluminum End Clamps. are used to attach and support framed photovoltaic modules to the system. The End Claps are not used as a grounding means. ° The Grounding Mid'Clamps are installed onto the module frame by using a 18-8 stainless steel 4 - serrated T -Bolt and a 18-8 stainless steel Flange Hex Nut that gets screwed onto the rails to a De_sc_ription, ` specified torque. The retention teeth of the clamp and bolt penetrate the anodized coating of the photovoltaic modules frame and rail to contact the metal, creating a bonded connection' from module to module and module to rail.. , ` Y The grounding of the entire system is intended to be in accordance with the latest edition of the „ National Electrical Code, including NEC 250: Grounding and Bonding, and NEC 690: Solar, . .0 Photovoltaic Systems. Any local electrical codes must be adhered in addition to the national electrical codes. An entire array, regardless of size, is grounded via one grounding lug. The WEEB Grounding Lug is secured to XRL, XR10, XR100 or XR1000 Rail's top slot using stainless steel hex bolt or T -Bolt, flat washer, split lock washer, and nut, tightened to .} . manufacture's specified torque. The WEEB Grounding Lug is intended for use with one solid or =" F stranded copper wire, conductor size 14 AWG though 6 AWG" The Titan Grounding Lug is . secured to XRL, XR10, XR 100 or XR 1000 Rail's side center cavity of rails using stainless steel T -bolt, k -lock nut, star washer, and machine screw. The Titan Grounding Lug is intended for 9 _ use with one solid or stranded copper wire, conductor size 14 AWG though 4 AWG. Models _ '_':.' IR XR followed by 4 Alphanumeric Characters Model Similarity N/A Fuse Rating: 20 A .1" Fire Class Resistance Rating: Class A for Steep Slope Flush -Mount (Symmetrical) Applications when using Type 1, ` Type 2 and Type 3, Listed Photovoltaic Module. Class A for Low Slope Flush -Mount (Symmetrical) Applications when using Type 1, Ratings y�' - Type 2 and Type 3, Listed Photovoltaic Module. Class A for Steep Slope Tilt -Mount (Asymmetrical) Applications when using Type 1 and Type 2, Listed Photovoltaic Module. '• ' N'r 3 ' - �' - Class A for Low Slope Tilt -Mount (Asymmetrical) Applications when using Type 1, Type 2 and Type 3, Listed Photovoltaic Module. x - Page 1 of 86' ' This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client Intertek's responsibility and 4 - • ' liability are limited to the terns and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the u agreement, for an loss, expense or dam occasioned b the use of this re Only the Client is authorized to permit copying or distribution of this report and - " - . a9 Y Pe � Y report. Y Pe PY n9 Po .. • then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not Imply that the a material, product, or service is or has ever been under an Intertek certification program. ED 76.3.15 (1 -Jen -13) Mandatory rN 25800 Commercentre Drive Lake Forest, CA 92630 USA Telephone: 949.448.4100 Facsimile: 949.448.4111 www.intertek.com Test Verification of Conformity ol— i. .. ._r - ,. In the basis of the tests'undertakeri; the sample(s);of,the below+product have:been foundao complyFwith;the requirementsof, ' the referenced specifications'at,thetlme the tests`were�carried out.. . N Applicant Name & Address: Irohkidge, Inc.` w "= '1495`Zephyr`Ave r ; " Ha',yward,:CA 94544, - , ' `, • „ T' 'Product Description: XR'Rails with -Integrated Grounding. Ratings'9 Principle Fire ClassResistance. Rating: Characteristics: Class A for Steep Slope'Flush Mount (symmetrical)'Applications when using Type 1'and a �'Type'2,'Listed -.Photovoltaic,Module' . ' F i =Class A for Low,Slope Flu°sh-Mount and Tilt=Mount (symmetrical. and asymmetrical) Applications when`using'Type 1' Listed Photovoltaic Module.L ' odels: ; 51 61GD-OOSB,�51-5000-001; and 51-65-001' , _ -; •.. � , � u, . ' • Brand'Name: ."T N/A' Relevant Standards:. _, UL -Subject 2703 (Section 152 and"15.3) Outline'of Investigation for''Rack Mourning Systems and' . +�Clamping'Devices for•Flat-P,,late Photovoltaic Modules and Pan6ls;`Issue Number: 2, Nov`?3, 2012 Referencing 'UL1703 (Section 31:2) Standard for Safety for: Flat-Plate'Photovoltaic Modules and' F -.Panels, YMay 20,2014% Intertek Testing -Services NA, Inc.' Verification'Issuing Office _ 25800 Commercentre:Dr c ..' r Lake Forest, CA 92630 Date of Tests. '68/27/2014 to 01/07/2015' t Test Report: Number(s): 101541132LAX-002 ,. This verification.is,part of the full test report(s);andjshould:be,read'in;conjunction with:them',Thi's report does not automatically imply product certification. r ti,. r �`' r ' • `` + } I - +' , J• . t.� .. 4r4. •i, Y. i. i • ' n • as .. 7 .. ... . � :' 'k'f i .}.'- - ,% ,. *a y 'r �b • .�f 1'1 I'• J: xyn- �f ..' sa } t. - �; ° "' .. = r: y, 6 _ L { .-1a ... +H;`r �' .9y M� I F, ,y` _,'' d' .• ••, •, r ' i ` "Y•. completed by: Amar.Kacel ;'; =Reviewed by: ; :Andrew,Koretoff • Title: PV -Engineer- ` ' 4 Title: , �'. Reviewer " .Y} z n t �.. . Signature: ---� F ,.,.Signature I Date: 01/26/2015 ,Date: 01/26/2015.: This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product or service is or has ever been under an Intertek certification program. GFT -OP -11 a (24 -MAR -2014)