Loading...
HomeMy WebLinkAboutB18-0191 000-000-000ALG(MSIN� 2693 CAMULOS WAY REDDING, CA 96002 PH.- (503) 356-4797 LICENSE #966369 FIRE SPRINKLER EQUIPMENT SUBMITTAL FOR: CA TES RESIDENCE TIGER LILY LANE FOREST RANCH, CA 95942 A.P.N. 056-280-070 TABLE OF CONTENTS PIPE AND FITTINGS ➢ BLA7EMAS7ER CPVC PIPE AND FITIYNGS HANGERSAND BRACING ➢ TOLCO SIDE MOUNT HANGER ➢ TOLCO SINGLE OFFSET HANGER ➢ TOLCO DOUBLE OFFSET HANGER SPRINKLER HEADS AND DEVICES ➢ SENJURESIDENTIAL SPRINKLERS MISCELLANEOUS ➢ P07TER FLOW SWITCH ➢ P07—TTR ELECTRIC BELL ➢ WILKINS BACKFLO W ➢ AM7,ROL FIRE-X-TROL EXPANSION TANK ➢ ANTIFREL%E — GLYCERINE SHOP DRA WINGS 100111186 Q � F el, Pg 9663 G X36 PERMIT #_� t - C-' BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR C DE COMPLIANCE DATE Z- BY�� r --A LE- 4f,-�-ry Product Specifications ��r1 P HARSW° '=R Harvel® Blazemastee CPVC Fire Sprinkler Pipe 10 Application: Corrosion resistant fire sprinkler pipe, IPS sizes 3/4" through 3", for use in wet automatic fire sprinkler systems. When installed in accordance with Harvel's Installation Instructions, this pipe is Listed by Underwriters Laboratories (UL) for use in: Light Hazard Occupancies as defined in the Standard for Installation of . Sprinkler systems (NFPA 13); Residential Occupancies up to and including four stories in height (NFPA 13R); and Residential Occupancies as defined in the Standard for Sprinkler Systems in One and Two Family Dwellings and Mobile Homes (NFPA 13D). Harvel BlazeMaster, pipe is UL Listed for use in Return Air Plenums (NFPA 90A), System Risers per NFPA 13 Light Hazard, 13R and 13D, Exposed installations, Garages per NFPA 13R, and for use as Underground Fire Service Mains (NFPA 24) when installed in accordance with Harvel CPVC Fire Sprinkler Pipe Installation Instructions. Scope: This specification outlines minimum manufacturing requirements for Chlorinated Polyvinyl Chloride (CPVC) standard dimension ratio (SDR) 13.5 series iron pipe size (IPS) fire sprinkler pressure pipe. Pipe is intended for use in wet automatic fire sprinkler sys tems when installed in accordance with Harvel Plastics, Inc. CPVC Fire Sprinkler Piping Products Installation Instructions. Harvel, BlazeMaster, pipe carries a maximum working pressure of 175 psi @ 150°.F. Pipe meets or exceeds applicable industry standards and requirements as set forth by the American Society for Testing and Materials (ASTM), the National Sanitation Foundation (NSF), and Underwriters Laboratories (UL). Harvel, BlazeMaster, fire sprinkler pipe is approved by the Factory Mutual Corporation (FM) and the Loss Prevention Certification Board (LPCB). Refer to current approval guide and installation and design manual for installation limitations. CPVC Materials: . The material used in the manufacture of the pipe shall be a rigid chlorinated polyvinyl chloride (CPVC) compound, Type IV Grade I, with a Cell Classification of 23547 as defined in ASTM D1784. The compound and the finished product shall be orange in color, and shall be approved by the National Sanitation Foundation (NSF) for use with potable water. Material used shall be domestically produced BlazeMaster, CPVC material as provided by Noveon, Inc. (formerly the BFGoodrich Company). System Design: The CPVC sprinkler system shall be hydraulically calculated using a Hazen -Williams C factor of 150, and shall be designed in strict accordance with the Standard for Installation of Sprinkler Systems; NFPA 13 Light Hazard, NFPA 13R, and NFPA 13D as applicable. Dimensions: Harvel BlazeMaster, CPVC fire sprinkler pipe shall be manufactured to Standard Dimension Ratio (SDR) 13.5 dimensions in strict accordance to the requirements of ASTM F442 for physical dimensions and tolerances. Each production run of pipe manufactured in compliance to this standard, shall also meet the test requirements for materials, workmanship, burst pressure, flattening, and extrusion quality defined in ASTM F442. Furthermore, this pipe shall consistently meet or exceed the physical performance test requirements of the appropriate approval/listing agency(s) follow-up procedures established for the product. - Marking: Product marking shall meet the requirements of ASTM F 442 and the Listing agency. Marking shall include: the phrase Harvel® BlazeMaster® (or the manufacturers' trademark when privately labeled); the nominal pipe size; the type of material and material designation code; the SDR series and pressure rating for water (SDR 13.5; 175 psi @ 150°F); the ASTM designation F 442; the logo of the Listing and Approval agencies (UL, FM, LPCB, etc.); the independent laboratory's seal of approval for potable water usage (NSF-pw); the date and time of manufacture; and the UL assigned control number (2N95). Installation Procedures: All installation procedures such as storage and handling, solvent cement joining techniques, pipe support spacing, bracing, allowance for thermal expansion/contraction, component assembly techniques, and testing etc. shall be in strict accordance with Harvel Plastics, Inc. Installation Instructions and the UL Listing which includes installation limitations. System Components: Fittings used shall be UL Listed CPVC fittings and shall meet or exceed the requirements of ASTM F437 (Sch 80 threaded), ASTM F437 (Sch 80 socket), or ASTM F438 (Sch 40 socket) as applicable, such as those manufactured by Spears Manufacturing Co. or equivalent. Solvent cements used shall be those referenced in Harvel Plastics, Inc. Installation Instructions (such as Spears FS -5 or equivalent), -which meet or exceed the requirements of ASTM F656 and ASTM F493, and shall be approved by the National Sanitation Foundation (NSF) for use with potable water. Socket .type joints, sizes 3/4" - 3", shall be made up using the One -Step solvent cement joining method. The solvent cement joining method chosen shall be applied in strict accordance with the appropriate procedures as outlined in Harvel Plastics Installation Instructions. Maintenance: Maintenance shall be in accordance with the Standard for Inspection, TI sting, and Maintenance of Water Based'Sprinkler Systems as defined by NFPA 25. Harvel Plastics, Inc. • 300 Kuebler Rd.; Easton, PA 18040-9290 Tel: 610.252.7355 • Fax: 610.253.4436 • www.harvelsprinklerpipe.com /7\ Product Specifications Harvel®. Blazennastee CPVC Fire Sprinkler Pipe Limitations: • CPVC systems are intended for use at a maximum working pressure of 175 psi and ambient temperature of 150°F. • CPVC systems shall employ sprinkler heads having a maximum temperature rating of 225"F or lower, regardless of type. • CPVC products shall be installed in wet pipe systems only. • Air or compressed gas shall never be used for pressure testing. • CPVC sprinkler systems shall be hydrostatically tested for 2 hours at 200 psi, or 50 psi in excess of the maximum working pressure when the maximum working pressure exceeds 150 psi. Lines shall be slowly filled with water and the air bled from the highest and farthest sprinkler heads before test pressure is applied. • Only Teflon® tape or a thread sealant specifically approved for ' use with Harvel® CPVC Fire Sprinkler Products shall be used in making threaded connections. • Where freeze protection is required, only glycerin based anti -freeze solutions shall be used and installed in accordance with NFPA 13. Do not use glycol base anti -freeze solutions or contaminated glycerin solutions. • CPVC is not approved for use in combustible concealed spaces where' sprinklers are required to protect these areas as defined - by NFPA 13, unless certain specific application sprinklers are installed per their listing. Refer to Harvel's current Installation Instructions for additional information. Harvel CPVC Fire Sprinkler Pipe Dimensions SDR 13.5 (ASTM F442) • CPVC sprinkler piping may be installed in a plenum space adjacent to, but not over, openings in the ceiling such as open ventilation grills, and require the use of schedule 80 fittings for use on 11/2" and larger pipe sizes. Refer to Installation Instructions for additional detail. • Minimum protection when installed "concealed" shall consist of 3/8" gypsum wallboard or drywall, suspended membrane ceiling panels weighing not less than .35 pounds per square foot, or 1/2" plywood soffits. Minimum protection for NFPA 13R and 13D systems may consist of 1/2" plywood. • Harvel, BlazeMaster, pipe is Listed for use in exposed applications with certain limitations. When installed without protection, "exposed" pipe is to be installed beneath smooth, flat, horizontal ceiling construction. Exposed categories include: standard coverage and residential pendent and sidewall sprinkler applications, light hazard extended coverage and residential sprinkler pendent and sidewall sprinkler applications, use in unfinished basements with exposed solid wood joists, light hazard upright quick response sprinklers, and system risers (in 13R & 13D occupancies). Refer to Harvel's installation instructions for specific sprinkler head temperature ratings and spacing requirements. The product must be installed in strict accordance with NFPA 13, 13D, 13R and Harvel's current CPVC Fire Sprinkler Piping Products Installation Instructions (HFS-3). • Harvel CPVC Fire Sprinkler Products must be installed in accordance with Harvel's current installation instructions (H FS -3). Refer to this document for current listing limitations and Nominal Average Min. Average Nom.Wt. installation requirements. Size (in.) O.D. Wall I.D. Lbs./Ft. ASTM STANDARD D1784 MATERIAL CLASSIFICATION 3/4 1.050 0.078 0.874 0.168 EQUIVALENTS: 1 1.315 0.097 1.101 0.262 1-1/4 1.660 0.123 1.394 0.418 Cell Classification 23447 = CPVC" j y I-112 1.900 0.141 1.598 0.548 Type IV Grade I = CPVC 4120' �:�"°?' `` 2 2.375 0.176 2.003 0.859 PIPE SIZES SHOWN ARE 2-1/2 2.875. 0.213 2.423 1.257 MANUFACTURED IN STRICT' 3 3.500 0.259 2.950 1.867 COMPLIANCE WITH ASTM F442 Hm#M.R 'IAm • i'Gt�lgiey�lee�fBra. . �ii�a•cE �:L9itV iiDQ1- �. . Sample Specification: All CPVC fire sprinkler pipe shall be manufactured from a Type IV, Grade I Chlorinated Polyvinyl Chloride (CPVC) compound with a Cell Classification of 23547 per ASTM D1784. Pipe shall be manufactured in strict compliance with ASTM F442 to SDR 13.5 dimensions, con- sistently meeting the Quality Assurance test requirements of this standard with regard to material, workmanship, burst pressure, flatten- ing, and extrusion quality. All CPVC fire sprinkler pipe shall be Listed by Underwriters Laboratories for wet pipe systems, and shall carry a rated working pressure of 175 psi @ 150'F All CPVC fire sprinkler pipe shall be installed in accordance with Harvel Plastics, Inc. CPVC Fire Sprinkler Piping Products Installation Instructions. National Fire Protection Association (NFPA) Standards 13, 13D, and 13R must be referenced for design and installation requirements in conjunction with the Installation Instructions. All CPVC fire sprinkler pipe shall be manufactured in the USA by an ISO 9001 certified manufacturer and shall be FM and LPCB approved. All CPVC fire sprin- kler pipe shall be packaged immediately after its manufacture to prevent damage and shall be stored indoors after production, at the manufacturing site, until shipped from factory. This pipe shall bear the logo of the listing agencies, and shall carry the National Sanitation Foundation (NSF) seal of approval for potable water applications. All CPVC fire sprinkler pipe shall be Harvel® BlazeMaster® pipe as manufactured by HARVEL® PLASTICS, INC. Harvel Plastics, Inc. • 300 Kuebler Rd., Easton, PA 18040-9290 Tel: 610.252.7355 • Fax: 610.253.4436 • www.harvelsprinklerpipe.com ®m .-w - - _ � ... .,« . _..- .r .....,....s' -4--""r.^- :vw».•� •'-mac F1ameGuarw-.....,,1'-'*,,1,-"" CPVC FIRE SPRINKLER PIPING PRODUCTS - • Y t TECHN]CAL INFORMATION _ WEIGHTS & DIMENSIONS',..' .....January 1,1�-- SUFERSEDESALL PREWOVS EDITIONS Z TU 1 '' - - � -• ," • - '..,L �y �� � 'Ido '. AZI Ak ..19 69 .w'r .. - � , _ � � �•y ';r, ♦ fir. r � _ Visit our web site M Corpo,afo Facllitles,-Splm •CA 9, 4, • • • C■ •� � • 1 Assessed fo. ISO 9001: 2000MJ { I yyy...''',,yyy,,,ti j � �-1� fes: >� � .. '.� t."y. r f• ♦ .. � �s``f,�t' ylp3yr 'F p : Fti "� - ,�C A •. I ED FlameGuard'" CPVC FIRE SPRINKLER PIPING PRODUCTS The information contained in this publication is based on current information and Product design at the time of publication and is subject to change without notification. Our ongoing commitment to product improvement may result in some variation. No representations, guarantees or warranties of any kind are made as to its accuracy, suitability for particular applications or results to be obtained therefrom. For verification of technical data or additional information not contained herein, please contact Spears° Technical Services Department [West Coast: (818) 364-1611—East Coast: (717) 938-90061. General Information RECOMMENDATIONS FOR INSTALLERS AND USERS: Plastic piping systems should be ENGINEERED, INSTALLED and OPERATED in accordance with ESTABLISHED DESIGNAND ENGINEERING STANDARDS AND PROCEDURES for plastic piping systems. Suitability for the intended service application should be determined by the installer and/or user prior to installation of a plastic piping system. All Installation and maintenance personnel should be trained in the proper handling and installation requirements and precautions of plastic piping systems. PRIOR TO ASSEMBLY, all piping system components should be inspected for damage or irregularities. Mating components should be checked to assure that tolerances and engagements are compatible. Do not use any components that appear irregular or do not fit properly. Contact the appropriate manufacturer of the component product in question to determine usability. Consult all applicable codes and regulations for compliance prior to installation. Installation must be made in accordance vvith Spearse Manufacturing Company FlameGuardTM CPUC Fire Sprinkler Piping Products Installation Instructions - FG -3 NOTE — Individual or group instruction in correct solvent welding procedures is available by contacting your local distributor or your servicing Spears® Regional Distribution Center. SOLVENT CEMENT CONNECTIONS — Spears® Manufacturing Company recommends the use of Spears° Two Step FS -1 primer with FS -3 solvent cement OR Spears" FS -5 One Step solvent cement for joining Spears° products. Use of solvent cementing products not approved for CPVC fire sprinkler systems, or failure to follow installation instructions will automatically void the warranty. THREADED CONNECTION — Spears° Manufacturing Company recommends the use of Spears® BLUE 75 T Thread Sealant. This product has been tested by Spear0and the sealant manufacturer for compatibility with the Spears° CPVC fire sprinkler products. Consult the sprinkler head manufacturer before using this product. VIARNING: OTHER PIPE JOINT COMPOUNDS OR PASTES MaY CONTAIN SUBSTANCES THAT COULD CAUSE STRESS CRACKING IN THE CPVC OR OTHER FITTING COMIONENTS. Care must be taken to avoid over torquing - generally 1 to 2 turns beyond finger tight is all that is required to make up a threaded connection. Factory testing has indicated 10-25 ft. lbs. of torque is adequate to obtain a leak free seal. GASKET SEALED THREAD CONNECTIONS — This type of connection can only be made with Spears° TorqueSafeTM style Gasket Sealed Female Sprinkler Adapters. DO NOT USE ANY TYPE OF THREAD SEALANT WHEN INSTALLING THIS TYPE OF ADAPTER. Tape or paste may impair proper sealing and function. Testing has shown that hand tight until snug is all that is needed to seal this special connection. NOT FOR USE WITH COIVPRESSED AIR OR GASES MRNING: DO NOT USE COMPRESSED AIR OR GAS TO TEST ANY PVC OR CPVC THERNDPLASTIC PIPING PRODUCT OR SYSTEM AND DO NOT USE DEVICES PROPELLED BY COIVPRESSED AIR OR GAS TO CLEAR SYSTEN6. THESE PRACTICES NAY RESULT IN EXPLOSIVE FRAGMENTATION OF SYSTEMPIPING AND COMPONENTS CAUSING SERIOUS OR FATAL BODILY INJURY. Dimension Reference G = (LAYING LENGTH) Intersection of center lines to bottom of socket/thread; 90° elbows, M = Outside diameter of socket/thread hub; t 1/16 inch. tees, crosses; t 1132 inch. N = Socket bottom to socket bottom; couplings; ± 1/16 inch. H = Intersection of center lines to face of fitting; 90° elbows tees, crosses; ± 1/32 inch. Q = Width of flats; ±1/16 inch. J = Intersection of center lines to bottom of socket/thread; 45° elbows; ± 1/32 inch W = Height of cap; ± 1/16 inch. L = Overall length of fittings; t 1/16 inch. CPVC FIRE SPRINKLER PIPE SDR 135(ASTMF 444 Part Number Nominal Size Average O. D. Average I. D. Approx. Wight Lbs.�Ft. Inches (mm) Inches (mm) Inches (mm) CP -007 314 (19.1) 1.050 (26.7) .874 (22.5) .181 CP -010 1 (25.4) 1.315 (33.4) 1.101 (28.2) .280 CP -012 1-114 (31.8) 1.660 (42.2) 1.394 (35.6) .418 CP -015 1-112 (38.1) 1.900 (48.3) 1.598 (40.7) .550 CP -020 2 (50.8) 2.375 (60.3) 2.003 (50.9) .872 CP -025 2-112 (63.5) 2.875 (73.0) 2.423 (61.5) 1.260 CP -030 3 (76.2) 3.500 (88.9) 2.950 (75.0) 1 1.900 SPEARS° MANUFACTURING COMPANY FlameGuard'" CPVC FIRE SPRINKLER PIPING PRODUCTS TEE Socket x Socket x Socket I I M — —1— _ LH�—�G L Part Number Size G H L M Approx. W. (Lbs.) 4201-007 314 9/16 1-112 2-31132 1-5/16 .11 4201-010 1 29132 1-13116 3-518 1-518 .19 4201-012 1-114 15132 2-3132 4-7/32 2 .29 4201-015 1-112 1-5132 2-9/16 5-3132 2-11/32 .54 4201-020 2 1-13132 2-15116 5-718 2-7/8 .79 4201-025 2-112 1-23132 3-112 7 3-15/32 1.62 4201-030 1 3 1 2-1116 3-15/16 7-7/8 1 4-3116 3.02 REDUCING TEE Socket x Socket x Socket r--►rM1 Hl m I M - 2 M2 G1 fG2 H H2 es— L Part Number Size G G1 G2 H H1 H2 L M M1 w Approx. W. lbs.) 4201-102 314x3/4xl 3/4 25/32 3/4 1-11/16 1-13116 1-11116 3-318 1-5116 1-21/32 1-5116 .13 4201-125 10/43/4 21/32 1 13116 518 1 1-25132 1-13116 1-518 3-7/16 1-17/32 1-5116 1-5/16 .16 4201-126 1x3/4x1 314 1-7/8 1-3132 1-27132 2-31132 1-31132 3-13116 1-23132 1-23/32 1-13132 .26 4201-131 lxlx314 21132 13116 21/32 1-25132 1-13116 1-25132 3-9116 1-5/8 1-5/16 1-518 .16 4201-157 1-11400/4 11/16 1-1132 11/16 1-15/16 2-1132 1-13116 3-25/32 2-3132 1-13/32 1-23/32 .32 4201-158 1-1/4xlxl 27/32 29/32 25/32 2-1116 2-1132 1-29132 3-15116 1-31/32 1-518 1-518 1 .24 4201-159 1-1/4xlxl-1/4 31/32 31132 31/32 1 2-7/32 2-7132 2-3/32 4-11132 2-3132 2-3132 1-23/32 .35 4201-167 1-1141-1143/4 21/32 1 21132 1-29132 2 1-29132 3-13116 1 2 1-5116 2 .22 4201-168 1-1141-1141 13116 1 13116 2-1116 2-118 2-1116 4-118 1-31/32 1-5/8 1-31/32 .24 4201-169 1 -1/4x1 -1/4x1-112 1-1/8 15116 1-118 2-318 2-11132 2-318 4-314 2-3132 2-11/32 2-3132 .51 4201-201 1-1/2x1-1/4314 11116 1 114 2-1/16 2 1-15/16 4 2-5116 1-3/8 2-1116 .41 4201-202 1 -1/2x1 -1/4x1 27132 1-1132 1 1 2-7/32 2-5132 2-1/4 4-15132 2-5116 1-11116 2-1116 .42 4201-210 1 -1/2x1 -112x3/4 23/32 1-1116 23/32 2-3132 2-1132 2-3132 4-3116 1 2-5/16 1-318 1 2-5116 .37 4201-211 1 -1/2x1 -1/2x1 13/16 1-3116 13116 2-3116 2-114 2-3/16 4-318 2-11132 1-23132 2-11132 .41 4201-212 1 -112x1 -112x1-114 1 1 1-1/8 1 2-3/8 2-11132 2-318 4-13/16 2-11132 2-3/32 2-11132 .48 4201-213 1 -112x1 -112x2 1-5/16 1 1-1/8 1-5116 2-11116 2-21132 2-11116 5-318 2-11/32 2-27132 2-11132 .72 MADE IN THE U.S.A. I En FlameGuard'" CPVC FIRE SPRINKLER PIPING PRODUCTS REDUCING TEE (continued) Socket x Socket x Socket —►�-M1 T M - M2 G1 G2 H H2 L Part Number Size G G1 G2 H H1 H2 L M Mt NP Approx. W. (Lbs.) 4201-248 2x2x3/4 11116 1-13/32 11/16 2-7132 2-7116 2-7132 4-7116 2-27132 1-318 2-27/32 .52 4201-249 2x2xl 27132 1-7116 27/32 2-11/32 2-9/16 2-11/32 4-23132 2-718 1-314 2-718 .57 4201-250 2x2xl-1/4 1 1-11132 1 2-17132 2-19132 2-17132 5-3132 2-27/32 2-3132 2-27132 .63 4201-251 WO -112 1-7132 1-13132 1-7132 2-11116 2-25132 2-11116 5-318 2-27132 2-11/32 2-27/32 .85 4201-289 2-112x2-1120 29/32 25132 29/32 2-21132 1-29/32 2-21132 5-5/16 3-1/2 1-23/32 3-1/2 1.03 4201-290 2 -1/2x2 -1/2x1-1/4 1-3132 1-23132 1-3/32 2-27/32 1-27/32 2-27/32 5-11116 3-112 2-3132 3-112 1.19 4201-291 2 -112x2 -1/2x1-112 1-3/16 112 1-3116 2-15116 1-718 2-15116 1 5-7/8 3-15132 2-11132 1 3-15/32 1.26 4201-292' 2 -112x2 -112x2 1-19132 2-118 1-19/32 3-11132 3-518 3-11/32 6-11116 3-17132 3-17132 3-17/32 2.46 4201-335" 3x3xl 1-7/16 2-7116 1-7116 3-5116 3-23132 3-5116 6-5/8 4-5132 2-7/8 4-5/32 2.00 4201-336' 3x3x1-1/4 1-318 1-314 1-318 3-5116 3-1/2 3-5/16 6-5/8 4-118 2-7/8 4-118 1.94 4201-337' 3x3xl-1/2 1-318 2 1-318 3-5/16 3-518 3-5/16 6-518 4-1/8 2 4-118 1.85 4201-338 3x3x2 1-7116 1-13116 1-7116 1 3-5/16 1 3-5116 1 3-5/16 6-518 4-5/32 2-718 4-5/32 1.68 4201-339 3x3x2-112 1-3/4 1-31132 1-314 1 3-5/8 1 3-23/32 1 3-518 7-1/4 4-5/32 3-7116 4-5132 2.08 ' Branch Outlet Sized with Bushing 3-11/16 2-5/16 1-7/32 2-1/16 1 .37 4202-209 1-1/20-1/20/2 1/2 1-23/32 1 1/2 1-7/8 2-3/32 1-718 SPRINKLER HEAD TEE Brass Thread Insert Style Socket x Socket x Fipt }�Mt I 1 H1 - -1- - M2 1M L E.— G2 H H2 L Part Number Size G G1 G2 H H1 H2 L M M1 NQ Approx W. (Lbs.) 4202-101 3/4x3/4x1/2 7/16 1-5/32 7116 1-7116 1-17132 1-7116 2-29132 1-318 1-7132 1-318 .27 4202-124 1x3/41/2 7116 1-5116 9/16 1-9/16 1-11116 1-9116 3-1/8 1-11116 1-17/32 1-318 .31 4202-130 1x1x1/2 7116 1-5116 7116 1-9116 1-11/16 1-9116 3-118 1-23132 1-17132 1-23132 .32 4202-010 1x1x1 11116 1-3/32 11116 1-13/16 1-29/32 1-13116 3-19/32 1-23/32 1-23/32 1-23/32 .37 4202-156 1-1/400/2 7116 1-15132 9116 1-11/16 2-1132 1-11116 3-3/8 2-3/32 1-7/32 1-3/4 .30 4202-166 1 -114x1 -114x112 7/16 1-9116 7116 1-11116 1-15116 1-11/16 3-3/8 2-1116 1-17/32 2-1116 .37 4202-199 1-1/20-1/41/2 112 1-5/8 9116 1-718 2-3116 1-13116 1 3-11/16 2-5/16 1-7/32 2-1/16 1 .37 4202-209 1-1/20-1/20/2 1/2 1-23/32 1 1/2 1-7/8 2-3/32 1-718 3-314 2-5/16 1 1-17132 2-5/16 .45 4202-237 20-1/20/2 112 1-718 17132 2 2-7/16 1-29132 3-15116 2-27/32 1-7/32 2-5/16 .48 4202-247 2x2xl/2 112 1-31132 1 1/2 2 2-3/8 2 4-1132 2-27/32 1 1-17/32 2-27132 .58 SPEARS° MANUFACTURING COMPANY =FlameGuard'" CPVC FIRE SPRINKLER PIPING PRODUCTS Ej SPRINKLER HEAD TEE Special Reinforced Plastic Thread Style Socket x Socket x SR Fipt M1� TG1 I M - --f-- - M2 G2 H H2 L Part Number Size G G1 G2 H H1 H2 L M MI W Approx. W. (Lbs.) 4202-101 SR 3143/41/2 518 25/32 518 1-518 1-15132 1-518 3-7132 1-13/32 1-3/16 1-13/32 .16 4202-124SR 10/4112 7/16 29132 9116 1-19/32 1-5/8 1-9/16 3-5132 1-23132 1-3/16 1-17132 .19 4202-130SR 1x1x1/2 7116 7/8 7116 1-9/16 1-5/8 1-9116 3-1/8 1-23/32 1-7116 1-23/32 .25 4202-010SR 1x1x1 21132 3/4 21132 1-25132 1-21/32 1-25132 3-19132 1-23132 1-7/8 1-23132 .35 4202-156SR 1-1/4xlx112 15/32 1-5/32 19132 1-23132 1-718 1-23/32 3-13132 2-3132 1-3116 1-23132 .26 4202-166SR 1 -114x1 -114x112 7/16 1-118 7116 1-11/16 1-27/32 1-11116 3-318 2-3/32 1-3/16 2-3132 .26 4202-168SR 1 -1/4x1 -1/4x1 27132 1-1132 27132 2-3132 1-29/32 2-3132 4-7/32 2-3/32 1-11116 2-3/32 .34 4202-199SR 1 -112x1 -114x112 9/16 1-9/32 1 17/32 1-15116 2 1-25132 1 3-23132 2-11/32 1 1-3/16 2-3132 .33 4202-209SR 1 -1/2x1 -1/2x112 1/2 1-114 1/2 1-7/8 1-31/32 1-718 3-3/4 2-11/32 1-3/16 2-11132 .35 4202-211SR 1 -112x1 -112x1 13116 1-7132 13116 2-7132 2-1/8 2-7132 4-15/32 2-11132 1-23/32 2-11132 .43 4202-237SR 2x1 -112x112 23/32 1-9116 3/8 2-7/32 2-9/32 1-314 3-31132 2-7/8 1-3116 2-11132 .45 4202-247SR 2x2x112 112 31/32 112 1 2 1-11/16 1 19132 4 2-7/8 1-3116 1 2-718 48 4202-287SR 2 -1/2x2 -1/2x112 17132 1 1-3/4 1 17132 1 2-9132 1 2-112 1 2-9132 1 4-19/32 3-112 1-7132 1 3-112 .78 SPRINKLER HEAD TEE Brass Thread Insert Style Socket x Fipt x Socket "+7h M - G2 H H2 - L Part Number Size GG1 G2 I H H1 H2 I L I M KI M2 Approx. W. (Lbs.) 4203-122 1x1/2x1 9/16 25132 1-13/32 1-9116 1-27/32 1-25/32 3-11/32 1-518 1-518 1 1-17132 .29 MADE IN THE U.S.A. 4 SFERI6S =FlameGuard'" CPVC FIRE SPRINKLER PIPING PRODUCTS SPRINKLER HEAD TEE Special Reinforced Plastic Thread Style Socket x SR Fipt x Socket M1_'�� G1 I M - - M2 L G H L H2 2 `F Part Number Size G G1 G2 H -H1 H2 L M MILl- Approx. W. (Lbs.) 4203 122SR 1x112x1 27!32 314 1-3132 1-23132 1-518 11-13/16 3-7/16 1-23132 1-231322 .21 STREET TEE Spigot x Socket x Socket M1 ODE#GG2 H1 G1 Part Number Size G G1 G2 H H1 H2 L Mi M2 Approx. W. (Lbs.) 4244-007 3/4 13116 27132 27/32 1-13116 1-718 1-718 3-5/8 1-13132 1-13132 .16 4244-010 1 1-5132 1-1132 1-1132 2-118 1-29/32 1-29132 4-3116 1-3/4 1-314 .27 4244-012 1-114 1-114 1 1 2-7116 2-9132 2-9/32 4-27132 2-3/32 2-3132 .42 ' 4244-015 1-1/2 1-13116 1-118 1-1/8 2-718 2-9116 2-9116 5-11/32 2-11/32 2-11/32 .56 4244-020 2 1-11116 1-7116 1-7/16 3-1/4 2-29132 2-29/32 6-1/8 2-27/32 2-27132 .84 5 SPEARS° MANUFACTURING COMPANY FlameGuard'" CPVC FIRE SPRINKLER PIPING PRODUCTS SPEARS 99 ELBOW Socket x Socket r Size JG H LI ` H Part Number Size G H M Approx. Wt. (Lbs.) 4206-007 314 9/16 1-112 1-5/16 .07 4206-010 1 23/32 1-19132 1-518 .11 4206-012 1-114 718 2-5132 2 .21 4206-015 1-112 1-5132 2-17/32 2-318 .41 4206-020 2 1-13132 2-29/32 2-718 .45 4206-025 2-112 1-5/8 3-7116 3-7116 1.17 4206-030 3 1-29/32 3-23/32 4-3/16 1 1.80 SIDE OUTLET ELBOW Size G Socket x Socket x Socket H H1 M 1 NM Approx. W. (Lbs.) 4206-131 - — M 13/16 1-3/4 1-25/32 1-19/32 G H Part Number Size G H M Approx. Wt. (Lbs.) 4213-007 3/4 27132 1-19/32 1-5116 .09 4213-010 1 314 1-7/8 1-5/8 .17 REDUCING 99 ELBOW Socket x Socket Part Number Size G G1 H H1 M 1 NM Approx. W. (Lbs.) 4206-131 1x3/4 21/32 13/16 1-3/4 1-25/32 1-19/32 1-9/32 .11 MADE IN THE U.S.A. 6 Ei FlameGuardT" CPVC FIRE SPRINKLER PIPING PRODUCTS SPRINKLER HEAD 9(7 ELBOW Special Reinforced Plastic Thread Style Brass Thread Insert Style Socket x SR Fipt Socket x Fipt • H1� G1 - G H1 M1 G1 I- G HI L - I - M1 I I~ M H I Part Number Size G G1 H H1 M MI Approx. W. (Lbs.) 4207-101SR 3140/2 11132 13/16 1-15/32 1-112 1-13/32 1-3/16 .14 4207-130SR 1x1/2 7116 7/8 1-9/16 1-518 M 1-3/8 .20 4207-131SR 1x314 1/2 718 1-5/8 Part Number Size G G1 H H1 M MI Approx. W. (Lbs.) 4207-101 314112 7/16 1-5/32 ' 1-23132 1-17132 1-13/32 1-17132 .25 4207-130 1x1/2 15/32 1-518 1-9/16 1-11/16 1-23/32 1-17132 .28 4207-131 1x3/4 1/2 1-1/4 1-5/8 1-27/32 1-23/32 1-13132 .23 4207-166 1-1141/2 1 15132 1-17132 1-11/16 1 1-15/16 2-3/32 1-17/32 .33 SPRINKLER HEAD 9(Y ELBOW Special Reinforced Plastic Thread Style Socket x SR Fipt • H1� G1 - G M1 I- HI L I I~ M Part Number Size G G1 H H1 M MI Approx. W. (Lbs.) 4207-101SR 3140/2 11132 13/16 1-15/32 1-112 1-13/32 1-3/16 .14 4207-130SR 1x1/2 7116 7/8 1-9/16 1-518 1-23/32 1-3/8 .20 4207-131SR 1x314 1/2 718 1-5/8 1-9116 1-23/32 1-3/8 .16 4207-166SR 1-1/40/2 13132 1 1-1/32 1-21/32 1-23/32 1 2-3/32 1-7/32 .19 SPEARS° MANUFACTURING COMPANY FlameGuard'" CPVC FIRE SPRINKLER PIPING PRODUCTS El 99 STREET ELBOW o J Spigot x Socket Size H J M Approx. W. (Lbs.) - 314 H1 G1 7/32 1-13132 .09 4216-010 1 G 9/32 1-25132 .14 4216-012 1-1/4 - M1,. 5/16 2-3/32 .20 4216-015 1-1/2 1-7/16 13/32 1-318 .19 4216-020 2 H + 318 2-27/32 .43 4216-030 3 2-3/8 112 4-5132 1.00 PIPE O.D. Part Number Size G G1 H H1 Ml Approx. W. (Lbs.) 4209-007 3/4 15/16 17132 1-15/16 1-17/32 1-3/8 .12 4209-010 1 1-9/32 23/32 2-13/32 1-27132 1-3/4 .21 4209-012 1-1/4 1-9116 27/32 2-13/16 2-3132 2-3/32 .32 4209-015 1-1/2 1-15/32 1-3116 2-27/32 2-9/16 2-11132 .42 4209-020. 2 1-23132 1-3/8 3-7132 2-15/16 2-27/32 .65 22-1 ELBOW Socket x Socket o J Part Number Size H J M Approx. W. (Lbs.) 4216-007 314 1-3116 7/32 1-13132 .09 4216-010 1 1-318 9/32 1-25132 .14 4216-012 1-1/4 1-112 5/16 2-3/32 .20 4216-015 1-1/2 1-7/16 13/32 1-318 .19 4216-020 2 1-718 + 318 2-27/32 .43 4216-030 3 2-3/8 112 4-5132 1.00 MADE IN THE U.S.A. 0 En FlameGuard'" CPVC FIRE SPRINKLER PIPING PRODUCTS 22=1/2 STREET ELBOW Spigot x Socket 1� H1 J1 M1 �.. H j PIPE O.D. Part Number Size H H1 J 11 MI Approx. W. (Lbs.) 4242-007 3/4 1-1/4 1-1/2 114 112 1-3/8 .08 4242-010 1 1-7/16 1-11/32 5/16 7132 1-23132 .14 4242-012 1-1/4 1-9/16 1-25/32 17/32 11/16 2-1/16 .21 4242-015 1-1/2 1-13/32 1-23132 1/2 11/32 2-11/32 .28 4242-020 2 1-29/32 2-1/8 7132 5/8 2-718 .42 4242-025 2-1/2 2-1/8 2-114 13132 1/2 3-112 .68 4242-030 3 2-13/32 2-13132 9/16 17/32 4-5/32 .99 45 ELBOW Socket x Socket I H I Part Number Size H J M Approx. Wt. (Lbs.) 4217-007 314 1-5/16 5/16 1-5/16 .10 4217-010 1 1-15132 11/32 1-518 .11 4217-012 1-114 1-5/8 3/8 2-5/32 .21 4217-015 1-1/2 1-27/32 15/32 2-11/32 .32 4217-020 2 2-118 21132 2-7/8 .48 4217-025 2-112 2-1/2 3/4 3-112 .96 4217-030 13 12-314 17/8 4-5/32 1.22 SPEARS° MANUFACTURING COMPANY FlameGuard'" CPVC FIRE SPRINKLER PIPING PRODUCTS SPE�BS . 4S STREET ELBOW G1 M - L1 1 -�--- H1 G H L Spigot x Socket Size G G1 H H1 L L1 M Approx. W. (Lbs.) 4220-007 J� H1 5/8 518 1-21132 1-21/32 3-5116 3-5/16 1-13/32 .22 J1 M1 1 314 314 1-5/8 1-518 3-114 3-114 1-23/32 , H J 4220-012 1-114 1-1/8 1-1/8 2-3/8 2-318 4-3/4 4-3/4 2-3/32 .63 4220-015 - 1-112 1-7/32 1-7132 2-518 2-518 1 5-1/4 I= •I PIPE O.D. 2-11/32 .80 4220-020 Part Number - , Size H H1 J 11 M Approx. M. (Lbs.) 4227-010 1 1-112 1-5/16 112 114 1-5/8 .10 4227-012 1-114 1-25/32 1-9/16 9/16 11132 1-31/32 .15 4227-015 1-112 2-1132 2-118 19/32 25/32 2-11/32 .29 4227-020 1 2 1 2-5/16 1-15/16 25/32 1 13/32 2-718 .44 CROSS Socket x Socket x Socket x Socket • G1 M - L1 1 -�--- H1 G H L Part Number Size G G1 H H1 L L1 M Approx. W. (Lbs.) 4220-007 314 5/8 518 1-21132 1-21/32 3-5116 3-5/16 1-13/32 .22 4220-010 1 314 314 1-5/8 1-518 3-114 3-114 1-23/32 .20 4220-012 1-114 1-1/8 1-1/8 2-3/8 2-318 4-3/4 4-3/4 2-3/32 .63 4220-015 - 1-112 1-7/32 1-7132 2-518 2-518 1 5-1/4 5-1/4 2-11/32 .80 4220-020 2 1-112 1-1/2 3 3 6 6 3 1.43 4220-025 2-112 1-23/32 1-23/32 3-13132 3-13/32 6-13116 6-13/16 3-112 2.11- 4220-030 3 2-3/32 2-3132 3-31132 3-31132 7-15/16 7-15/16 4-7116 3.37 MADE IN THE U.S.A. 10 En FlameGuard'" CPVC FIRE SPRINKLER PIPING PRODUCTS REDUCING CROSS ---- --- N M Part Number Size L Socket x Socket x Socket x Socket N Approx. W. (Lbs.) 4229-007 314 2-118 1-5116 3116 .05 4229-010 1 2-3116 r--►rMl 3132 .08 4229-012 1-114 2-19132 2 3132 .13 H1 1-112 2-718 2-11132 3132 .22 4229-020 2 M ---'-- L1 118 .33 4229-025 2-112 3-11116 3-15132 3116 L G1 3 4 4-3116 114 .89 G L H Part Number Size G G1 H H1 L L1 M MI Approx. W. (Lbs.) 4220-131 1x314 718 518 2 1-518 4 3-114 1-27132 1-112 .35 4220-167 1-114314 1-1116 23132 2-1116 1-31132 4-3132 3-31132 2-1116 1-13132 .35 4220-289 2-112x1 29132 1-314 2-11116 2-718 5-11132 5-314 3-112 1-314 .98 COUPLING Socket x Socket ---- --- N M Part Number Size L M N Approx. W. (Lbs.) 4229-007 314 2-118 1-5116 3116 .05 4229-010 1 2-3116 1-518 3132 .08 4229-012 1-114 2-19132 2 3132 .13 4229-015 1-112 2-718 2-11132 3132 .22 4229-020 2 3-118 2-718 118 .33 4229-025 2-112 3-11116 3-15132 3116 .48 4229-030 3 4 4-3116 114 .89 11 SPEARS° MANUFACTURING COMPANY FlameGuard'" CPVC FIRE SPRINKLER PIPING PRODUCTS El � REDUCER COUPLING Socket x Socket ML---- --- M1 L Groove x Socket Part Number Size L M RM N Approx. W. (Lbs.) 4229-131 1x3/4 2-3/8 1-23132 1-13/32 7132 .10 4229-167 1-1/43/4 2-19/32 2-3/32 1-518 11/32 .17 4229-168 1-1/4x1 2-11/16 2-3/32 1-23132 5/16 .18 4229-210 1-1/20/4 2-13/16 2-11132 1-13/32 15/32 .19 4229-211 1-112x1 2-7/8 2-11/32 1-15116 318 .24 4229-212 1-1/2x1-114 2-25132 2-318 2-3/32 5132 .22 4229-248 2x314 3-3/16 2-718 1-7/16 23132 .32 4229-249 2x1 3-118 2-7/8 1-23/32 1/2 .31 4229-250 2x1-114 3-3/16 2-718 2-118 17/32 .33 4229-251 2x1-112 3-3116 2-27132 2-11/32 9132 .31 4229-291 2-112x1-1/2 1 3-23/32 1 3-15132 12-11/32 1 21/32 1.51 4229-292 2-1/2x2 1 3-21/32 1 3-112 1 2-718 1 13/32 1 .52 GROOVED COUPLING ADAPTER Groove x Socket PIPE- _ O.D. M1 L Part Number Size L MI N Approx. W. 4233-012 1-1/4 3-518 2-3/32 2-11/32 .72 4233-015 1-1/2 3-314 2-11/32 2-11/32 .83 4233-020 2 3-27/32 2-27/32 2-11/32 1.27 4233-025 2-112 3-318 3-112 1-21/32 .52 4233-030 3 3-9116 4-5/32 1-23/32 .72 MADE IN THE U.S.A. 12 Ei FlameGuard'" CPVC FIRE SPRINKLER PIPING PRODUCTS -- - j FE MILE ADAPTER Special Reinforced Plastic Thread Style Brass Thread Insert Style , Socket x SR Fipt Socket x Fipt .. I M ---- M1 L M -- - M1 1.- L Part Number Size L M MI L Approx. W. (Lbs.) 4235-007SR 314 .1-7/8 1-13132 Part Number Size L M MI N Approx. W. (Lbs.) 4235-007 314 2 1-13/32 1-318 5116 .23 4235-010 1 2-9132 1-314 1-29/32 13/32 .38 4235-012 1-1/4 2-3/8 2-3132 2-1/16 13/32 .35 4235-015 1-1/2 2-9116 2-318 2-7/16 7/16 .47 4235-020 2 2-11/16 2-718 3-1/32 15/32 1.14 FEMALE ADAPTER Special Reinforced Plastic Thread Style Socket x SR Fipt .. I M ---- M1 L 1.- L Part Number Size L M MI N Approx. W. (Lbs.) 4235-007SR 314 .1-7/8 1-13132 1-318 118 .09 4235-010SR 1 2-5132 1-23132 1-718 3132 .22 4235-012SR 1-114 2-5116 2-118 2-1/16 3116 .20 13 SPEARS° MANUFACTURING COMPANY FlameGuard'" CPVC FIRE SPRINKLER PIPING PRODUCTS El FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style with Socket Wench Flats Special Reinforced PI asti c Thread Style Socket x SR Fipt M=Flat-toflat Dimension L I. L �I Part Number Size M ----- - M1 N Approx. W. (Lbs.) W4235-101SR 314112 2-9132 1-13132 1-3/16 L W4235-130SR 10/2 Part Number Size L M MI N Approx. W. (Lbs.) 4235-101SR 3/41/2 1-13/16 1-13/32 1-3/8 3132 .12 4235-130SR 1x1/2 1-31132 1-23132 1-3/8 3132 .16 4235-131SR 1x3/4 2-3132 1-314 1-3/8 114 .13 FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style with Socket Wench Flats Socket x SR Fipt M----------------- M1 M=Flat-toflat Dimension L I. L �I Part Number Size L M MI N Approx. W. (Lbs.) W4235-101SR 314112 2-9132 1-13132 1-3/16 17/32 .09 W4235-130SR 10/2 2-9132 1-3/4 1-3/16 13132 .12 MADE IN THE U.S.A. 14 FlameGuard'" CPVC FIRE SPRINKLER PIPING PRODUCTS FEMALE SPRINKLER HEADADAPTER Special Reinforced Plastic Thread wAlbtal Thread Start Socket x SR Fipt M ------- M1 L Part Number Size L M w N Approx. W. (Lbs.) Z4235-101SR 314x112 1-718 1-318 1-7/16 3/16 .08 Z4235-130SR 1x1/2 2-1132 1-23/32 1-7/16 5/32 .17 SPIGOT FEMALE ADAPTER Brass Thread Insert Style Spigot x SR Fipt Spigot x Fipt PIPE - - - - - M1 O.D. L PIPEM1 O.D. N-11 L� JLN L Mt N Approx. W. (Lbs.) Part Number Size L Mi N Approx. W. (Lbs.) 4278-007 314 2-1132 1-318 15132 .14 4278-010 1 2-15/32 1-23132 9/16 .27 SPIGOT FEMALE ADAPTER Special Reinforced Plastic Thread Style Spigot x SR Fipt PIPE - - - - - M1 O.D. L N-11 L� Part Number Size L Mt N Approx. W. (Lbs.) 4278-007SR 314 1-15116 1-3/8 11/32 .08 4278-010SR 1 2-1/4 1-23/32 13/32 .13 15 SPEARS° MANUFACTURING COMPANY FlameGuardT" CPVC FIRE SPRINKLER PIPING PRODUCTS SPE�AS GASKET SEALED FEM4LE SPRINKLER HEAD ADAPTER Brass Thread Insert Style Socket x Gasket Fipt E L L Part Nunter Size L M Mt N Approx. W. (Lbs.) 4235-130GS 1x1/2 2 1-11/16 1-17/32 1/2 .21 a FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style Socket x Fipt M ---- M1 L .Part Nunter Size L M MI N Approx. W. (Lbs.) 4235-101 3/41/2 1-718 1-13132 1-17/32 15/32 .19 4235-130 1x1/2 2-5/32 1-11/16 1-3/16 19/32 .16 4235-131 1x3/4 2 1-11/16 1-9/16 19/32 .18 FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style with Long Body Socket x Fipt MI - — - —- M1 L Imo— L Part Number Size L M W N Approx. Wt. (Lbs.) L4235-130 1x1/2 2-3/16 1-23/32 1-7132 1/2 .19 MADE IN THE U.S.A. 16 SPEARSFFIcameGuard` CPVC FIRE SPRINKLER PIPING PRODUCTS FEMALE SPRINKLER HEADADAPTER Brass Thread Insert Style with Positioning Ring Socket x Fipt M ---- M1 N Part Number Size L M w N Approx. W. (Lbs.) R4235-101 314112 2-1/32 1-7/16 1-3/16 15132 .15 FEMALE SPRINKLER HEADADAPTER Special Reinforced Plastic Thread Style with Positioning Ring Socket x SR Fipt M --- - -- M1 - L N L Part Number Size L MNM N Approx. W. (Lbs.) R4235-101SR 3/41/2 1-15/16 1-7/16 1-7/32 7/32 .09 SPIGOT FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style Spigot x Fipt rw PIPE M1 O.D. 4• L Part Number Size L MI IN , Approx. W. (Lbs.) 4238-101 3/41/2 1-15/16 1-17/32 17/32 .18 4238-130 1x1/2 2-1/4 1-3/16 11/32 .19 17 SPEARS" MANUFACTURING COMPANY FlameGuard'" CPVC FIRE SPRINKLER PIPING PRODUCTS El BUSHING with BRASS THREAD INSERT Spigot x Fipt _ PIPE O.D. L� Part Number Size L Approx. W. bs. 4238-130BR 1x112 1 .13 SPIGOT FEMALE SPRINKLER HEAD ADAPTER --_— Special Reinforced Plastic Thread Style Q Spigot x SR Fipt Part Number Size L >} PIPE -----1 O.D. N N L-------- ►I Part Number Size L Nm N Approx. W.(Lbs.) 4238-101SR 3141/2 1-29/32 1-7/32 1/8 .07 4238-130SR 1x112 2-1132 1-7/32 7132 .09 IVpLE ADAPTER With CPVC Lined Thread Brass Insert Mipt x Socket --_— —_— M1 L Q Body 1Mdth Part Number Size L MI N Approx. Wt. (Lbs.) 4236-007 3/4 2-17/32 1-13132 13116 .15 4236-010 1 2-15/16 1-23132 29132 .30 4236-012 1-114 3-1/8 2-3/32 31/32 .50 4236-015 1-112 3-9132 2-11/32 31132 .80 4236-020 2 3-7116 2-7/8 31132 1.00 ADJUSTABLE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style FQ Socket x SR Fipt F... Body Widlh Part Number Size L N Min Max Min Max Q Body 1Mdth Approx. W. (Lbs.) 42001SR 3141/2 6-9132 8 4-7/16 6-1/4 1-7116 2-3116 .66 42011SR 1x112 6-13/32 8 4-112 6-1/8 1-7116 2-118 .68 MADE IN THE U.S.A. 18 . Ei =FlaimeGuard` CPVC FIRE SPRINKLER PIPING PRODUCTS ADJUSTABLE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Spigot x SR Fipt PIPE 0 Bodthy L Wid L N L Part Number Size 4237-131 Q Body 1Mdth Approx. W. (Lbs.) 114 Min Max Min Max 1-1/43/4 1-19/32 42004SR 3/40/2 5-1132 6-5116 1 3-3116 4-15132 1-5116 2-118 .36 42014SR 1012 6-7116 8-1/8 1 4-7116 6-1/4 1 1-7/16 2-3116 .67 REDUCER BUSHING Flush Style Spigot x Socket PIPE 0. D. L N _ L Part Number Size L N Approx. W. (Lbs.) 4237-131 1x314 1-114 114 .04 4237-167 1-1/43/4 1-19/32 17/32 .12 4237-168 1-1141. 1-13/32 9132 .06 4237-210 1-1/2x314 1-11/16 11116 .19 4237-211 1-112x1 1-17/32 13132 .15 4237-212 1-112x 1-1 /4 1-9/16 5116 .07 4237-248 2x314 1-29132 29132 .27 4237-249 , 2x1 1-29132 314 .25 4237-250 2x1-114 1-11116 7116 .21 4237-251 2x1-1/2 1-11116 5116 .15 4237-290 2-112x1-114 2-13132 1-5/32 .45 4237-291 2-1/2x1-1/2 2-13132 1-1132 .43 4237-292 2-112x2 2-9132 25132 .29 4237-338 3x2 2-114 3/4 .63 4237-339 3x2-112 2-5116 11/4 .40 19 SPEARS° MANUFACTURING COMPANY C�FlameGuard` CPVC FIRE SPRINKLER PIPING PRODUCTS CAP Socket M - — - �W Part Number Size M W Approx. W. (Lbs.) 4247-007 314 1-318 1-13/32 .05 4247-010 1 1-5/8 1-19/32 .06 4247-012 1-1/4 2-3/32 1-27/32 .13 4247-015 1-1/2 2-11/32 2 .17 4247-020 2 2-27/32 2-9/32 .39 4247-025 2-1/2 3-17/32 2-11/16 .48 4247-030 - 3 4-3/8 3 .92 TEST PLUG - 0 -ring Sealed Mipt - For Pressure Testing Only, Not For use with Z4235 Series Adapters L R. M1- ----- M 1/2-14 NPT Part Number Size L M Ml Approx. Wt. (Lbs.) FTP -005 1/2 1-27/32 1-15/16 1-7/32 .03 TEST PLUG for TorqueSafeTM Gasket Sealed Head Adapters Mipt - For Pressure Testing Only. Use ONLY with Gasket Sealed Head Adapters - L M1- ----- M 1 1/2-14 NPT Part Number Size L M MI Approx. W. (Lbs.) FTP-005GS 1/2 1-25132 2-1/32 1-1/4 .05 MADE IN THE U.S.A. 20 FlameGuard'" CPVC FIRE SPRINKLER PIPING PRODUCTS TEST PLUG (PVC White) Not UL Listed; For Pressure Testing Only, Mipt �.-- L -•I Part Number Size L Approx. Wt.(Lbs.) 4250-005 112 27/32 .02 FLANGE -ONE PIECE 4 Bolt Holes, 175 psi 4 Bolt Holes, 175 psi �R Socket if- BOLT CIRCLEDIA. -►i ��- M —� LT R No. of Bolt Mn. Bolt Part Number N BOLT CIRCLE DIA. Lt_ Bolt Size O.D. Approx. W. (Lbs.) MAX O.D. Circle Dia Holes Length 4253-007 314 No. of Bolt 4 Mn. 2 3-27132 .30 4253-010 1 23/32 3-118 4 112 Bolt 4-1/4 Max. Approx. W. Part Number Size L M N R Bolt Circle .40 Bolt 1-112 314 3-7/8 4 112 2-1/2 5-1132 .74 4253-020 Size 2 O.D. (Lbs.) 4 5/8 3 5-15116 .89 4253-025 Holes Dia 1-1/32 Len th 4 518 4251-007 3/4 1-5132 1-112 118 17132 4 2-314 1/2 2 3-29132 .31 4251-010 1 1-5116 1-13116 118 11116 4 3-118 112 2-114 4-9132 .35 4251-012 1-114 1-13/32 2-7132 5/32 11116 4 3-112 112 2-114 4-518 .44 4251-015 1-112 1-9116 2-112 3116 23/32 4 3-718 112 2-112 5 .52 4251-020 2 1-27132 3 11/32 718 4 4-314 518 3 5-31132 .95 4251-025 2-1/2 1 2-114 3-112 1 112 1-1132 4 1 5-1/2 1 518 3-114 1 6-15116 1 1.57 BLIND FLANGE 4 Bolt Holes, 175 psi �R if- BOLT CIRCLEDIA. -►i MAX O.D. Bolt No. of Bolt Mn. Bolt Part Number Size R Bolt Size O.D. Approx. W. (Lbs.) Circle Dia Holes Length 4253-007 314 17132 2-314 4 112 2 3-27132 .30 4253-010 1 23/32 3-118 4 112 2-114 4-1/4 .35 4253-012 1-114 21/32 3-112 4 112 2-1/4 4-518 .40 4253-015 1-112 314 3-7/8 4 112 2-1/2 5-1132 .74 4253-020 2 25132 4-314 4 5/8 3 5-15116 .89 4253-025 2-112 1-1/32 5-1/2 4 518 3-114 6-15116 1.70 4253-030 3 1-5116 6 14 1518 3-1/4 1 7-518 1 1.72 21 SPEARS° MANUFACTURING COMPANY 1 04 FlameGuard'" CPVC FIRE SPRINKLER PIPING PRODUCTS FLANGE -TWO PIECE Van Stone Style, 4 Bolt Holes, 175 psi Socket M ~� L R i i N T CIRCLE DIA.—I MAX O.D. El Bolt Cirde No. of Bolt Mn. Bolt Part Number Size L M N R Bolt Size Max. O.D. Approx. W. (Lbs.) Dia Holes I I Length 4254-030 3 1 2-1/8]-4-1/4 9132 1 1-1132 6 4 1 518 1 3-1/4 1 7-15/32 1.75 FLANGE -TWD PIECE Socket x Socket Van Stone Style, 4 Bolt Holes, 175 psi Spigot NUT M - - PIPE QD701 O.D. N N L Part Number L ' M N Nut O.D. Approx. W. (Lbs.) 4257-007 314 2-318 R F5BOLT CIRCLE DIA-+� 3 318 2-1/2 .38 4257-010 1 2-9116 1-27/32 MAX O.D. 2-7/8 .41 4257-012 1 1-114 2-27/32 2-7132 11/32 3-5116 Bolt No. of 1-112 3-118 2-112 318 3-17/32 .63 4257-020 2 3-5/8 3-1/32 Bolt Mn. Bolt Mix. 1.09 Part Number Size L N R Cirde Bolt Approx. W. (Lbs.) Size Length O.D. Dia Holes 4256-007 3/4 1-15/16 13116 17132 2-314 4 112 2 3-27132 .30 4256-010 1 2-7132 1-1132 11/16 3-118 4 1/2 2-114 4-114 .41 4256-012 1-114 2-318 1 11116 3-112 4 1/2 2-114 4-518 .50 4256-015 1-1/2 2-7/16 1-3132 23132 3-718 4 112 2-112 4-31132 .65 4256-020 2 2-314 1-5132 25/32 4-314 4 518 3 5-15116 1.00 4256-025 1 2-1/2 1 3-1/16 , 1-9132 1-1/32 5-112 4 518 3-114 6-15/16 1.62 4256-030 3 3-318 1-13/32 1 1-1132 1 6 4 1 5/8 1 3-114 1 7-9116 1.76 UNION Socket x Socket NUT M - - O.D. N L Part Number Size L M N Nut O.D. Approx. W. (Lbs.) 4257-007 314 2-318 1-17/32 318 2-1/2 .38 4257-010 1 2-9116 1-27/32 318 2-7/8 .41 4257-012 1 1-114 2-27/32 2-7132 11/32 3-5116 .52 4257-015 1-112 3-118 2-112 318 3-17/32 .63 4257-020 2 3-5/8 3-1/32 9116 4.3116 1.09 MADE IN THE U.S.A. 22 FlameGuard'" CPVC FIRE SPRINKLER PIPING PRODUCTS TRANSITION UNION SCH 40 - ASTM F438 Brass Thread Insert Style SCH 80 - ASTM F439 Socket x Fipt I� C -►I NUT - - - O.D. M Socket N L SCH 4OMnimum Part Number Size L M N Nut O.D. Approx. W. (Lbs.) 4259-010BR 1 2-718 1-27132 1 2-718 .56 4259-012BR 1-114 3 2-3116 1-118 3-9132 .98 4259-015BR 1-112 3-314 2-112 1-9116 3-17132 .93 4259-020BR j 2 j 4-3116 3-1132 j 1-27132 j 4-3116 j 1.57 SOCKET DIMENSIONS SCH 40 - ASTM F438 SCH 80 - ASTM F439 I� C -►I B A Socket Socket SCH 4OMnimum SCH 8DMnimum Size Tolerance EntranceA Bottom B Socket Length C Socket Length C 314 1.058 1.046 ± 0.004 0.719 1.000 1 1.325 1.130 ± 0.005 0.875 1.125 1-114 1.670 1.655 ± 0.005 0.938 1.250 1-112 1.912 1.894 ± 0.006 1.094 1.375 2 2.387 2.369 ± 0.005 1.156 1.500 2-112 2.889 2.868 ± 0.007 1.750 1.750 3 3.516 3.492 ± a.008 1.875 1.875 23 SPEARS° MANUFACTURING COMPANY Fig. 24 - Hanger for CPVC Plastic Pipe Double Fastener Strap Type - Side Mount Size Range — 3/4" thru 2" CPVC pipe Material — Pre -Galvanized Steel Function — Intended to perform as a hanger/restrainer to support CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. The Fig. 24 can also function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals — Underwriters' Laboratories Listed in the USA (UL) and Canada (WL) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge steel using (2) 1/4" x 1" tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features — Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a ham- mer) are allowed. Damage has been known to result from installations using impact type tools. No pre -drilling of a pilot hole in wood is required. Finish — Pre -Galvanized Order By — Figure number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. ' a A' Dimensions • Weights CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing (Ft.) Head Size WtJ100 3/4 25/16 15/32 13/16 51/2 5/16 9 1 25/8 1 V16 13/16 6 5/16 9 11/4 3 11/2 13/16 61/2 5/16 11 11/2 31/4 15/8 13/16 7 5/16 12 2 311/16 127/32 13/16 8 5/16 15 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 • www.toko.com Fig. 28M - Offset Hanger and Restrainer for CPVC Plastic Pipe and IPS Pipe Size Range — 3/4" thru 1-1/4" Material — Carbon Steel, Pre -Galvanized Function — Designed to be used as a hanger and restrainer for CPVC piping or steel piping where the "stand-off" design will ease installation by eliminating the need for wood blocking. Features — • Flared edge design protects CPVC pipe from any rough or abrasive surfaces • Unique snap -on design holds pipe firmly in place and allows retrofit type of installation • The "Stand -Off" design eliminates the need for wood block extension • Can be installed on horizontal or vertical piping regardless of mounting surface orientation • Attaches easily to wood structure with two hex head self -threading screws furnished with product • Installs easily using rechargeable electrical driver with 5/16" extension socket eliminating impact tool damage to pipe • Attaches easily to steel, minimum 18 gauge with (2) 1/4" x 1" tek type self drilling tapping screws • cULus Listed as a hanger and a restrainer for fire sprinkler piping Installation Note — When installed in wood structural member and threads from the #10 x 1 " screws are exposed, use FIG. 27B speed nut to secure Approvals — Underwriters' Laboratory Listed in the USA (UL) and Canada (cUL) to support automatic fire sprinkler systems. May be installed into wood using fas- teners screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28M satisfies the UL vertical restraint requirements where needed. Order By — Figure number and pipe size Patent #7,744,042 R r----------------------- I I I 4 I I Q Q I I d I I I I p I I I I I I I Q I I I Q I F - -----------I I I I I I I I I I I I I I I I A � I I _ RESTRAINT P 1 _ _____ __L ----L_ II II II pl II I ,I I TOLCO FIG. 27B—, „ (1) REQUIRED II II HIGH SIDE J; OFHANGER _r A C @US LISTED TOLCO FIG. 27B (2) REQUIRED II II II II HANGER AND RESTRAINT APPLICATION . DETAIL A HANGER APPLICATION ® OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.toko.com Dimensions • Weights Max. Spacing Pipe required per Approx Size A B C NFPA 13 for Wt./100 CPVC plastic pipe 3/4 2 3/16 3-5/16 5'-6" 9 1 2-1/8 3/16 3-1/2 6'-0" 12 1-1/4 2-5/16 3/16 3-1/2 6'-6" 13 DETAIL A HANGER APPLICATION ® OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.toko.com Fig. 29 - Double Offset Hanger & Restrainer for CPVC Plastic Pipe Size Range — Available in 3/4" and 1 " pipe sizes Material — Pre -Galvanized Steel Function — Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkler pipe. Provides double offset 1 1/2" x 1 1/2" from mounting surface. This design will ease installation by eliminating the need for wood block extension and allow retro -fit attachment of hanger to sprinkler pipe. Features — • Thumb tab provides protection to restrain pipe in rough job site conditions. Tab is not required to be bent for listed installation. • Offset edge eliminates abrasion. • Attaches easily to wood structure with two special #10 x 1 hex head self -threading screws furnished with product. • Can be used as a single offset hanger by aligning "dimples" with top of mounting surface and utilizing two fasteners in two of the three holes provided. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) as a hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements of NFPA 13, 13R and 13D. Finish — Pre -Galvanized Order By — Figure number and pipe size. PATENT PENDING C (9USLISTED Install using a rechargeable electric drill fitted with a 5/16" socket attachment with the special hex head self -tapping screws provided. Install screws until they bottom out. Pipe can be "snapped" into hanger before or after installation of the screws to the mounting surface. "Thumb tab" may be bent up to provide additional protection to the pipe, but is not required for performance of the hanger / restrainer function. OFFICEIMANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 43 7 Of 6 SENJU SPRINKLER CO.,LTD. Residential Lead Free Flat Concealed Sprinkler, Pendent, Model: RC -RES, K -Factor: 4.9, SIN: SS8464 GENERAL DESCRIPTION The Model RC -RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. These are decorative and fast response. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is in turn concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push -on and/or thread -on, thread -off design of the concealed cover plate assembly allows easy installation of the cover plate. Therefore, the Model RC -RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC -RES is designed for the residential occupancies and it is perfect for use in homes, hotels and other living quarters. The Model RC -RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 13D; wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC -RES has a 4.9 (70.6 LPM/bar'/2) K -factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC -RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC -RES allows for an increased chance of residents' escape or evacuation in case of fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. "Lead Free" is defined in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWWA's Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. IA,VA`i+A�i'M The Model RC -RES must be installed and maintained in accordance with the rules stated herein as well as in compliance with the applicable standards of the National Fire Protection Association regulations and the standards of any other authorities having jurisdiction. In the event of this condition, consult the authorities having jurisdiction for guidance and approval. Failure to do so may impair the integrity of these devices. It is the responsibility of the installing contractor to provide a copy of this document to the owner or his representative, and in tum, it is the obligation of the owner to provide a copy of this document to a succeeding owner. The owner is, responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any related questions. Document No. 0085160 Date : Feb/09/2015 TECHNICAL DATA Approvals: cULus Listed, NSF -61-G Sprinkler Identification Number (SIN): SS8464 Maximum Working Pressure: 175psi (12.1bar) Discharge Coefficient (Nominal K -Factor): K=4.9 GPM/psi"' (70.6 LPM/bar112) Temperature Rating: 162T (72°C) Sprinkler with 140T (60°C) Cover Plate 175T .(79aC) Sprinkler with 162T (72aC) Cover Plate Color Code (Sprinkler) 162T (72°C): Uncolored 17ST (79aC): White Color Code (Cover Plate) 140T (609C): No Mark 162T (72°C): White -Colored Mark Vertical Adjustment: 1/2 inch (12.8 mm) Cover Plate Finishes: Standard Finishes - White, Ivory, Beige, Brown, Black, Nickel, Wood Grain Custom Finishes - Custom color and custom pattern cover plates are available on special order. Contact a Senju Sprinkler representative with any custom orders. Please see chart on Page 8 for more detail. Physical Characteristics: Ref. Figure 1 OPERATION Page : 2 of 8 In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then, the Cover Plate is released at once. As a result, the Deflector drops down to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is recorded, internal components of the sprinkler to fall apart. This leads to allow the water flow to be distributed on the affected by fire area. (Ref. Figure 2) Normal Condition VIII* Cover Plate Operation y Sprinkler Operation =* Water Discharge FIGURE 2. OPERATION PROCESS (rhe figure is for illustrative purpose only)' Document No. 0085160 Date : Feb/09/2015 2— &" (0 52mm) NPT1 2 Markin Lot No. Year of Manufacture I —SIN : SS8464 —K—factor : K4.9 E Temperature Rating : I62'F/72'C E UL Mark I or 175*F/79-C Control No.: 6P37 NSF Mark : NSF -61—G ` RES SPKR N 01 Body (Copper Alloy) O Deflector (Phosphorus Bronze) O Gasket (PTFE) © Fusible Metal (Solder) ® Heat Collector (Copper) 2— % (� 68mm) ® Cover Plate Assembly or 3—,V4" (0 83mm) or 2— %"square (068mm) FIGURE 1. Model RC -RES K=4.9 Color Code 00 51N : 558464 K—factor. K4.9• 0 0 Temperature Rating 167F/77C or 175'F/7TC `. am UL Mark ccb 0 00 0 COVER PLATE SPRINKLER (Top view) (Bottom view) FIGURE 1-1. Marking (Color Code) In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then, the Cover Plate is released at once. As a result, the Deflector drops down to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is recorded, internal components of the sprinkler to fall apart. This leads to allow the water flow to be distributed on the affected by fire area. (Ref. Figure 2) Normal Condition VIII* Cover Plate Operation y Sprinkler Operation =* Water Discharge FIGURE 2. OPERATION PROCESS (rhe figure is for illustrative purpose only)' Document No. 0085160 Date : Feb/09/2015 Page : 3 of 8 DESIGN CRITERIA The herein stated rules for use and installation of Model RC -RES are provided by the manufacturer and must be strictly implemented for safe and full results. NOTES Residential Fire Sprinkler Systems should only be designed and installed by individuals who are completely familiar with automatic sprinkler system design, installation procedures, and techniques. Several criteria may apply to the installation and usage of each sprinkler. Consequently, it is recommended that the sprinkler system designer review and develop a working understanding of the complete list of criteria prior to initiating the design of the sprinkler system. Questions concerning sprinkler installation and usage criteria, which are not coverage by the following instructions, should be submitted to Contact Company. Include sketches and technical details as appropriate. In some instances, the requirements of this document may concern specifications which are more stringent and which take precedence over those specified in NFPA 13, 13D, 13R, or. by the authority having jurisdiction. The Model RC -RES must not be used in applications where the air pressure above the ceiling is greater than that below. Inspect all sprinklers after installation to ensure that both the gap between the cover plate, ceiling and the 6 slots in the cup are open and free from any air now impediment. The spray from the sprinkler is distributed radically outward and downward from the sprinkler deflector. Consequently, the sprinklers must be located such that there will be no blind spaces shielded from spray by partitions, room dividers, overhangs or other parts of the dwelling structure. The number of sprinklers within each compartment (as defined by NFPA 13, 13D, or 13R) must be kept as small as possible. Do NOT use more sprinklers than necessary to cover a particular space. Use only the Cover Plate provided with the Model RC -RES. The sprinkler must be secured in place by firmly fastening the sprinkler system piping to the structure. If the sprinkler is not properly secured in position, reaction forces 'resulting from sprinkler operation could alter its orientation and its water distribution pattern. Obstruction to Water Distribution Locations of sprinklers must follow the obstruction rules of NFPA 13 for Residential Sprinklers. General Service Conditions The Model RC -RES must only be utilized in WET PIPE sprinkler systems. Heat Source Criteria Refer to NFPA 13D or 13R for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC -RES, due to exposure to a heat sources other than an actual fire. Precautionary Warnings for Corrosive Environments The Model RC -RES should not be installed where they may be subjected to a corrosive environment including the following: (1) Chlorine ion and Chloride environment. Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non -Fire conditions or Not Operating when exposed to an actual fire. (2) Sprinkler system piping with Copper. Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for the copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM 8813, 8828, and CDA (Copper Development Association) —Solder Joint) ' All residual flux must be removed from the interior and exterior of copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and leakage in the sprinkler system. Hydraulic Design Criteria The minimum required sprinkler flow rates for system designed to NFPA 13D or 13R are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of "design sprinklers" as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the followings; The flow rates given in Table A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area. Document No. U085160 Date : Feb/09/2015 Page : 4 of 8 A minimum discharge 0.1GPM/sq.ft. [4.07LPM/sq.m] over the "design area" comprised of the four most hydraulically demanding sprinklers for the actual coverage areas being protected by the four sprinklers. TABLE A. NFPA 13D & 13R WET PIPE HYDRAULIC DESIGN CRITERIA for Model SS8464 Maximum Ordinary Intermediate Covera a Maximum Temperature Rating Temperature Rating Deflector Minimum raj Spacing 162T (72°C) 175T (79°C) Installation Spacing Area Ft. x Ft Ft to Ceiling Type Ft. Flow Pressure Flow Pressure (m xm). (m) GPM PSI GPM PSI (m) (LPM) (bar) (LPM) (bar) Smooth 12x12 12 13 7.0 13 7.0 Ceilings (3.7x3.7) (3.7) (49.2) (0.48) (49.2) (0.48) 3/8 to 7/8 Inches. 14x14 14 13 7.0 13 7.0 (4.3x4.3) (4.3) (49.2) (0.48) (49.2) (0.48) Beamed Ceilings per NFPA 16x16 16 13 7.0 14 8.2 13D,13R Concealed 8 (4,9x4.9) (4.9) (49.2) (0.48) (53.0) (0.57) or 13 (2.4) Installed in beam 18x18 18 17 12.0 18 13.5 3/8 to (5.5x5.5) (5.5) (64.3) (0.83) (68.1) (0.93) 7/8 inches 20x20 20 21 18.4 below (6.1 x6.1) (6.1) (79.5) (1.27) — — bottom of beam. (a) For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. (b) Requirement is based on minimum flow in GPM/LPM from each sprinkler. The associated residual pressures are calculated using the nominal K -Factor. Refer to Hydraulic Design Criteria Section for details. (c) For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R or 13 as applicable. Sprinkler Spacinq Criteria The minimum spacing between sprinklers is 8 feet (2.4m). The maximum spacing between sprinklers cannofgo beyond the coverage area calculated by using the specific hydraulic factors. (Ref. Table A) INSTALLATION The Model RC -RES must be installed in accordance with the following instructions. NOTES Do not use any sprinklers which have been subjected to potential mechanical damage. Do not use any sprinklers which show deformation or cracking in either the Sprinkler or the Protective Cap. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non -operation. The Protective Cap must remain on the sprinkler during installation and until the ceiling installation is completed. The Protective Cap must be removed to place the sprinkler in service. Document No. 0085160 Date : Feb/09/2015 Page : 5 of 8 Use a torque of 7 to 14 ft.lbs (9.5 to 19.0Nm) to achieve a 112 inch NPT sprinkler joint. If you exceed the recommended maximum torque, this could result in damage to the sprinkler inlet, which may lead to leakage from the sprinkler. In case of insufficient adjustment in Cover Plate installation, do not try to overly tighten, screw the sprinkler too loosely or make any modification to the cover plate assembly. Readjust the sprinkler fitting for a better fit. Installing Procedure Step 1 The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inch (50.8mm) as shown in Figure 3. Step 2 With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Sprinkler Socket or Wrench & Socket Combination (Ref. Figure 4). The grooves of the Socket must .fit perfectly with.the grooves on the Sprinkler for proper installation (Ref. Figure 4). Step 3 If desired the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with the 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the "Tolerance Limit of Ceiling Level' indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). Nt Mounting Surface Make a Space Here Do NOT Ave. y (6.4mm) Over Min. Y" (3.2mm) I ­40—rJ Mounting Surface 2- %" (0 60mm) Ceiling Hole Diameter CORRECT INCORRECT FIGURE 3. INSTALLATION FIGURE 4 Step 4 Use the Cap Remover RC to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just comes in contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has come in contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening of the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot come in contact with the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6 Document No. U085160 Date : Feb/09/2015 . Step 2 Hook by turning Step 3 1 Pull down FIGURE 5. PROTECTIVE CAP REMOVAL E E v E +I E N O I� C O v O v �c N +I O n /Ceiling Ceiling Ceiling INCORRECT CORRECT INCORRECT FIGURE 7. INSTALLATION (CORRECT OR INCORRECT) Document No, U085160 Date : Feb/09/2015 Page : 7 of 8 CARE AND MAINTENANCE The following instructions must be implemented for the maintenance and service of the Model RC -RES. NOTES Wet pipe sprinkler systems must be maintained at a minimum temperature of 40 T/4 `C to prevent freezing and bursting of the pipe and/or sprinklers. Automatic sprinklers are not to be tested with a heat source. Operation of the heat responsive element can result. Absence of a Cover Plate Assembly may delay the response time of the sprinkler in case of fire. Install the cover plate assembly properly, as shown in Figure 6. Improper installation of the cover plate assembly may cause improper operation or non -operation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the -new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted cover, plates. Non -factory applied paint may adversely delay or prevent sprinkler operation in case of a fire. Do not pull the Cover Plate. Separation may result. In preparation for maintenance of the fire protection system, permission to close the main control valve must be obtained from the proper authorities and all affected by this action parties must be informed before the maintenance session can commence. Do NOT enclose any sprinklers within drapes, curtains, or valances. Do NOT hang anything from the sprinklers. Do NOT clean the sprinklers with soap and water, detergents, ammonia, cleaning fluids, or other chemicals. Remove dust, lint, cobwebs, cocoons, insects, and larvae by gently brushing with a feather duster or gently vacuuming with a soft bristle (i.e., dusting) brush attachment. Exercise suitable safety precautions in the use and storage of highly flammable materials. The rapid rate of fire development and spread of these materials can reduce the ability of the sprinkler systems to aid in the control of a fire involving such hazards. Leaking or corroded sprinklers must be replaced. Automatic Sprinklers must never be shipped or stored where the temperature exceeds 100T /38°C. Automatic sprinkler must never be physically altered, such as painted, plated, or coated, once shipped from the factory. If the sprinklers have been in any way modified, they must be replaced. Great caution must be applied to prevent damage to the sprinklers at all stages - before, during, and after installation. Damaged units, as a result of dropping, hitting, over -tightening, or wrench slippage, must be replaced. The Model RC -RES must only be replaced with pendent sprinklers which are listed for residential fire protection service and which have the same nominal K -Factor, the same coverage area, and the same or lower flow ratings (as indicated under Table A "Hydraulic Design Criteria"). When remodeling, such as by adding false beams or light fixtures or changing the location of compartment walls, first verity that the new construction will not violate the installation requirements of the applicable standards of NFPA. Alter the new construction and/or the sprinkler system to suit the requirements of this document and the applicable NFPA regulations. The owner is responsible for the maintenance of the sprinkler system, including inspection and testing, its compliance with this documents, as well as the standards of the National Fire Protection Association (e.g., NFPA 25), and the regulations of any other authorities having jurisdiction. The owner should direct any questions regarding the above rules and regulations to the installing contractors or the sprinkler manufacturer. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with NFPA 25. Document No. 0085160 Date : Feb/09/2015 Page : 8 of 8 . ORDER PROCEDURE When placing an order, please contact a local distributor with the following information (Model Name, Specify, Temp. and Finish). Sprinkler: Model: RC -RES (SIN: SS8464, Residential Flat Concealed Sprinkler, Pendent, K4.9, Temperature: 162T (72°C) or, 175T (79°C) ) Cover Plate Assembly: 2-5/8 inch (068mm) or 3-1/4 inch (083mm) or 2-5/8 inch square (068mm), Order Separately from Sprinkler Please refer to the chart below for available sizes, temperature, and finishes. Tools for Installation of Model: RC -RES Socket for Model RC -RES Wrench & Socket for Model RC -RES Cap Remover RC Document No. 0085160 Date : Feb/09/2015 Standard Finishes Custom Finishes White Ivory Beige Brown Black Nickel Wood grain Custom Color Custom Pattem 2-5/8" Round, 140°F O O - - - O - O O 3-1/4" Round, 140°F O O O O O O O O O 2-5/8" Square, 140°F O - - - - - - O O 2-5/8" Round, 162°F O - - - - - - O O 3-1/4" Round, 162°F O - - - - -, - O O Tools for Installation of Model: RC -RES Socket for Model RC -RES Wrench & Socket for Model RC -RES Cap Remover RC Document No. 0085160 Date : Feb/09/2015 r FOR SMALL PIPE r •VSR—S r PO ER VANE TYPE WATERFLOW ® The Symbol of Protection ALARM SWITCH WITH RETARD UL, ULC, CSFM Listed and NYMEA Accepted Service Pressure: Up to 300 PSI (20,7 BAR) - - ` SII Flow Sensitivity Range for Signal: 4-10 GPM (15-38 LPM) UL ' Maximum Surge: 18 FPS (5,5 m/s) ' Enclosure: Die-cast, red enamel finish Cover held in place with tamper resistant screws + Contact Ratings: .Two sets of SPDT (Form C) 10.0 Amps -at 125/250•VAC 2.0- Amps at 30 VDC Resistive OmAmps min. at 24 VDC Conduit Entrances: Two openings provided for 1/2" conduit. Individual switch compartments suitable for i dissimilar voltages. Usage:' Listed'plastic, copper and schedule 40 iron pipe. Fits pipe sizes - I" (25mm), 1'1/4" (32mm), l 1/2" (38mm) and 2" (50mm) t Stock No. 1144440 , . Note: 12 paddles are furnished with each unit, one for each pipe size of threaded and sweat TEE, one for l" (25mm) CPVC, . one for 1" (25mm) CPVC (Central), one for 1,. threaded Ni6co CPVC, and one for 1 l/2" (38mm) threaded (Japan). Environmental Specifications: ' - • NEMA4/IP54 Rated enclosure suitable for indoor or outdoor , use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. • Temperature range: 40° F to 120° F, (4,5° C to 49° C) UL Service Use:. Automatic Sprinkler ` NFPA-13• One or two family dwelling NFPA-13D. Residential occu anc u to four stories NFPA-13R National Fire Alarm Code WPA-72 r' T Optional: Cover Tamper Switch Kit, Stock No. 0090148 (See Fig. 7 for terminations) , ' r ' Replaceable Components: Retard/Switch Assembly, stock no. 1029030 The Model VSR-S is a vane type waterflow switch for use on' Installation sprinkler systems that use I" (25mm), 1'/4" (32tnm), 1%" (38mm) or 2" These devices may be mounted in horizontal or vertical pipe. -On (50mm) pipe size. The unit 'May also be used as a sectional waterflow horizontal pipe they should be installed on the top side of the pipe where . detector on large systems., they will be accessible. The units should not be installed within 6" (15cm) The unit contains two single pole double throw snap action switches and of a valve, drain or fitting which changes the direction of the waterflow. } an adjustable, instantly recycling pneumatic retard. The switches are Select the proper paddle for the pipe size and type of TEE used see Fig. actuated when a flow of 10 gallons per minute (38 LPM) or more occurs I for instructions on changing paddle. The unit has a 1" NPT bushing " downstream of the device. The flow condition must exist for a period of for threading into a non -corrosive TEE. See Fig. 2 for proper TEE size, time necessary to overcome the selected retard period. type and installation. Use no more than three wraps of teflon tape. Screw the device into the TEE fitting as shown in Fig. 2. Care must be Enclosure The VSR-S switches and retard device are enclosed in a general purpose, taken to properly orient the device for the direction of waterflow. _ - ''die-cast housing. The cover is held in place with two tamper resistant The vane must not rub the inside of the TEE or,bind in any way. The ' screws which require a special key for removal. A field installable cover . • stem should move freely when operated by hand. tamper switch is available as an option which may be used to indicate • The device can also be used in copper or plastic pipe installations with unauthorized removal of the cover. See bulletin number 5401103 for the proper adapters so that the specified TEE fitting may be installed installation instructions of this switch. r = on the pipe run. • Note: Do not leave cover off for an extended period of time. Potter Electric Signal Company, LLC • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com -PRINTED IN USA MFG. #5401206 - REV G PAGE 1 OF 3 V 12/08 (E) -P+ FOR SMALL PIPE VSR—S OTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Fig. l ` Retard Adjustment DO NOT LEAVE COVER OFF FOR EXTENDED PERIOD OF TIME Thetimedelayisfactorysetat30f Iuseconds. CO """""" """ The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting (60- 90 seconds). The time delay should be set at the minimum required to prevent false alarms. DIRIiCI'ION OP MOUNT SU "VI.iz FLO1V - ARRUW UE � • IN DIRECT POINTS IE DIRf:CT10E OF ♦ WATERFLOW 1 -NPT THREADED FI'1"rNC ON AWARNING There are 12 paddles fitmished with each unit One for each size of threaded, sweat or plastic TEE as described in Fig. 2. These paddles have raised lettering that shows the pipe size and the of TEE that they are to be used with. The proper paddlemustbeused.The paddlemustbeproperly attached (see drawing) and the screw that holds the paddle must be securely tightened ALL Sias RLN OFTHE TEE MAY Ur: THR!ADEDOR SWEAT PIPE: DIREC wAT Shown with optional Cover Tamper Switch Kit. Fig. 3 Switch Terminal Connections Clamping Plate Terminal J Fig. 2 • PLON M ; 11 IIIR'1 APPROX. _ i 1 DF.I'PIt l i Screw the device into the tee fitting as shown. Care must be taken to properly orient the device for the direction of waterftow. On sweat tees, no threaded bushings, inserts, or adapters are permitted, unless they comply with the dimensions listed in the chart below. Important - The depth to the inside bottom of the tee should have the following dimensions: Appm,,i—tc Depth Requi—ert, Tee Size Th—ded Swett CPVC 1"x 1" 21/16" 1 3/4" 27/16" 1 1/4" x 1 1/4" x 1" 2 7/16" 2 7/16" N/A 1 I/2" x 1 1/2" x 1" 2 11/16" 2 1/4" N/A 3 3/16" 2 3/4" N/A AWARNING Do not use more than three wraps of teflon tape. AWARNING An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. . Fig. 4 Typical Electrical Connections ' - Fig. 7 Cover Tamper Switch Wiring (Shown with cover in place) C N.O. N.C. (WHT) (RED) (13LK) ' DH'G?ERI(pl x_ Fig. 5 Fig. 6 To remove knockouts: Breakout thin sectionofcoverwhenwiring NEGATIVE D NE•UTRALACC OR Place screwdriver at edge of both switches from one conduit entrance. knockouts, not in the center. 'ITIVE DC OR r� I1\ TAC \ j I / W ZONE ON L Noes: 1. The Model VSR-S has two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other is used to operate a local audible or visual annunciator. 2. For supervised circuits see "Switch Terminal Connections" drawing and caution note (Fig. 3). PRINTED IN USA MFG. 05401206 - REV G PAGE 2 OF 3 12/08 } {R Fes.. .- -, • .'' 'f• - •_ r. �'. -• -• 'r .• `- - ,. .. - •• ii FOR SMALL PIPE. : VSR—S ' P POTTER y` ; ' VANE TYPE WATERFLOW: -The Symbol of Protection - ALARM SWITCH WITH RETARD r Testing f..' Removal .The frequency of inspection "and testing'for the Model VSR-S and, its --To prevent accidental water damage, all control valves should associated protective monitoring system should be in accordance with _ be shut tight and the system completely drained before waferflow, applicable NFPA Codes and Standards and/or, the authority having detectors are removed or replaced. ' jurisdiction (manufacturer recommends quarterly or more frequently.) . Turn off electrical power to the detector,`then disconnect wiring. An inspector's test valve (usually locatedatthe endofthe mostremote branch Use a wrench on the flats of the bushing. Turn the switch r line) should always be used for test purposes. If there are no provisions for 'counterclockwise to disengage the pipe threads. testing the operation of the flow detection device on the system, application Gently lift with your fingers, roll the vane so it will fit through the of the VSR-S is not recommended or advisable. „ 'hole while continuing to lift the waterflow detector. minimum flow of 10 gpm (38 Lpm) is required to activate this device. ' Lift detector clear of pipe. w Please advise ttie•person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions.- -Maintenance nstructions.- •Maintenance ' Inspect detectors monthly for leaks. If leaks are found, replace the detector. The VSR-S waterflow switch should provide years of trouble- . free service. The retard and switch assembly are easily field replaceable. „ In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #102903 0. There i= is no maintenance required, only. periodic testing and inspection. Mounting Dimensions t ` 3.50" —moi - '� 5.56" 4 - �— GROUND SCRE\1'S 1 . �'.� (89.0 min) ; ~ ! (141.2 mm) .- ` C ' ` � - r x_ •'� {+: 2.00' -moi t n•m) •) .f ,• ;� . _' - i r ; I— : � . • •2.34" mac'` �(S�O.R, I • (59.4 mm) •�• - 4. I ' ( .I - Ili . I - •. +�_�>�,+, - .. _J •4 '' 4.89" .. - .. F e ®L- •� .' « • •. - (52.3 nim), ,. �,- ROW T i • 'I -11 112 NPT .J �, . ` ,...... - ✓. - - DWG# 1206-5 w ti r - , PRINTED IN USA, MFG. 85401206 - REV G jPAGE 3 OF 3 Size inches (mm) Voltage '_ Model Number Stock Number „ Current (Max.) Typical dB at 10 ft. (3m) (2) L POTTERY BELLS R The Symbol of Protection PBA -AC & MBA -DC 1750070 UL, ULC, and FM Approved " 85 Sizes Available: 6" (150mm), 8" (200mm) and.10" (250mm) ®® Voltages Available: 24VAC r . ®T 120VAC .12A 12VDC(10.2 to 15.6) Polarized " • ti ` 24VDC (20.4 to 31.2) Polarized Polarized .12VDC Service Use: Fire Alarm why' General Signaling or Burglar Alarm n� Environment: Indoor or outdoor use (See Note 1), MBA246 -400.to 150°F (400 to 66°C) ` = (Outdoor use requires weatherproof backbox.) j Termination: AC Bells - 4 No. 18 AWG stranded wires UC DC Bells-- Terminal strip L * ' Finish: Red powder coating ' 91 Optional: Model BBK-1 weatherproof backbox ' Model BBX-l,deep weatherproof backbox These vibrating type bells are designed for use as fire, burglar or general Notes: - signaling devices. They have low power consumption and high decibel I. Minimum dB ratings are calculated from integrated sound pressure ratings. The unit mounts on a standard 4" (101 mm) square electrical box measurements made at Underwriters Laboratories as specified in UL for indoor ttse or on a model BBK-1 weatherproof backbox or BBX-1 Standard 464. UL temperature range is -300 to 150°F (-340 to 660C). deep weatherproof backbox for outdoor applications. Weatherproof • 2. Typical dB ratings are calculated from measurements made with a backbox model BB_K=1, Stock No: 1500001. conventional sound level meter and are indicative of output levels in 8 (200) ' an actual installation. PBA248 3. ULC only applies to MB_ A DC bells. Size inches (mm) Voltage '_ Model Number Stock Number „ Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6(150) 12VDC MBA126 1750070 .12A, 85 76 8 (200) 12VDC MBA 128 1750080 .12A 90- 77 10(250)' .12VDC MBA1210 1750060 1 .12A' 92 78 ; 6 (150) '24VDC MBA246 1750100 .06A' 87 77 8 (200) 24VDC MBA248 ' 1750110 •.06A' ' 91 79 10 (250) 24VDC •MBA2410 1750090 .06A 94' 80 6 (150) 24VAC PBA246 1806024* .17A 91 78 8 (200) 24VAC PBA248 1808024* .17A 94 '-77 10 (250) 24VAC PBA2410 1810024* .17A 94 78 6(150) 120VAC PBA1206 1806120* ..05A. 92. 83 8(200). 120VAC PBA1208 1808120* OSA 99 84 �(2 5 rl10 (250) 120VAC PBA 12010 1810120* .05A 99 86 r All DC bells are polarized and have built-in transient protection.- *Docs not have ULC listing. f � A WAR N I N G • • • 1 • ' / - , • _ In outdoor or wet installations, bell must be mounted with ` "t " weatherproof backbox, BBK-I or BBX-l. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Potter Electric Signal Company, LLC • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www. potters ignal.com PRINTED IN USA • MFG. H5400776 - REV Y PAGE I OF 2 + 5;03 ' All DC bells are polarized and have built-in transient protection.- *Docs not have ULC listing. f � A WAR N I N G • • • 1 • ' / - , • _ In outdoor or wet installations, bell must be mounted with ` "t " weatherproof backbox, BBK-I or BBX-l. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Potter Electric Signal Company, LLC • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www. potters ignal.com PRINTED IN USA • MFG. H5400776 - REV Y PAGE I OF 2 + 5;03 ' P POTTER' R The Symbol of Protection Bells Dimensions Inches (mm) Fig. I D%%'G1! 776-I Weatherproof Backboz Dimensions Inches (mm) Fig. 2 Box has one threaded 1/2" conduit entrance o S 314" 3 (1461 O lS OP_ J 15�S" (R6) — I (41) 4 lis" (JOS) DWG4 716.2 Wiring (rear view) Fig. 3 A.C. BELLS BELLS . PBA -AC & MBA -DC N'HITI: (IN) WHfI'li (0171) 0 FRO\IC' IROL YAI�'IiL Olt YRI:CEDI\G HELL 0 tlL4CK H. HLACR (OI:I) CAUMO\: WHEN 1:1.I7C'I'RICAL SUPERVISION IS RIiQUIRED USE IN AND our LEADS AS SHOWN. NOTES: I. WHEN USING AC HELLS. TIMMINATI: EACH 1 .vrRA WIRE SITARAI'MY Arrl:R LAST HELL. 2. li\D-01%LINE RI:SIS'I'OR IS NOTREQUIREDONAC HELLS. , Installation I. The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90" AFF and not less than 6" below the ceiling. '. Remove the gong. 3. Connect wiring (see Fig. 3). 4. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 5. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 6. Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). WARNING Failure to install striker down will prevent bell from operating. PRINTED IN USA MFG. H5400776 - REV Y PAGE 2 OF 2 5!08 SPECIFICATION SUBMITTAL SHEET APPLICATION Designed for installation on potable water, lines to protect against both backsiphonage and backpressure of contami- nated water into the potable water supply. Assembly shall provide protection where a potential health hazard exists. FEATURES rt STANDARDS COMPLIANCE Sizes: ❑ 3/4" ❑ 1" ❑ 1 1/4" ❑ 1 1/2" ❑ 2" • ASSEO Listed 1013 Stainless Steel, 300 Series Elastomers Silicone (FDAApproved) IAPMOO Listed Maximum working water pressure 175 PSI • ULO Classified (less shut-off valves or with OS&Y valves) Maximum working water temperature 180°F • C-ULO Classified Hydrostatic test pressure 350 PSI • CSAO Certified End connections Threaded. ANSI 81.20.1 • AWWA Compliant C511 • Approved by the Foundation for Cross Connection OPTIONS SIZE A Control and Hydraulic Research at the University of . (Suffixes can be combined) VALVES C Southern California D • NYC MEA 425-89-M VOL 3 ❑ 'th f II QT b II 1 t d d G - wl u po a va ves (s an ar ) ❑ L - less ball valves ❑ U - with union ball valves ❑ MS - with integral relief valve monitor switch ❑ P - for reclaimed water systems - ❑ S - with bronze "Y" type strainer - ❑ BMS - with battery operated monitor switch ❑ FDC = with fire hydrant connection; 2" only ❑ TCU - with test cocks up ❑ V - with union swivel elbows (3/4" & 1") El - SE - with street elbows ❑' FT -`with integral male 450 flare SAE test fitting ACCESSORIES ❑ Air gap (Model AG) ❑ Repair kit (rubber: only) ❑ Thermal expansion tank (Model XT) ❑ Soft seated check valve (Model 40XL) ❑ Shock arrester (Model 1250) ❑ QT -SET Quick Test Fitting Set ` 01 Ball valve handle locks ❑ Test Cock Lock (Model TCL24) DIMENSIONS & WEIGHTS (do not include pkg.) MATERIALS Main valve body Cast Bronze ASTM B 584 Access covers Cast Bronze ASTM B 584 Fasteners Stainless Steel, 300 Series Elastomers Silicone (FDAApproved) Buna Nitrile (FDAApproved) Polymers NoryITM, NSF Listed Springs Stainless steel, 300 series E O F O O O Q O O O D C j' -A G Relief Valve discharge port: 3/4" - 1" - 0.63 sq. in. 1 1/4" - 2" - 1.19 sq. in. ••REVISION: BF-975XL(LG) 11111 Page 1 of 2 WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 In Canada: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1 L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1 -877 -BACKFLOW (1-877-222-5356) • Website: http://www.zurn.com DIMENSIONS (approximate) WEIGHT MODEL A UNION - B LESS BALL LESS WITH SIZE A BALL VALVES VALVES C D E F G BALL BALL VALVES VALVES in. mm in. mm in. I mm in. mm in. I mm in. I mm in. I mm in. I mm in. mm lbs I kg lbs. I kg 3/4 20 12-:- 305 133/4 349 73/4 197 21/81 54 3 76 31/2 89 5 127 161/8 410 10 4.5 12 5.5 1 25 13 330 141/2 368 73/4 197 21/8 54 3 76 31/2 89 5 127 173/8 441 10 4.5 14 6.4 1 1/4 32 17 432 1813/16 478 1015/16 278 23/4 70 3 1/2 89 5 127 63/4 171 22 9/16 573 22 10 28' 12.7 1 1/2 40 173/8 441 193/8 492 1015/16 278 23/4 70 3 1/2 89 5 127 63/4 171 241/16 611 22 10 28 12.7 2 50 181/2 470 201/2 521 1015/16 278 2 3/4 70 3 1/2 89 5 127 6 3/4 171 261/2 673 22 10 34 15.4 ••REVISION: BF-975XL(LG) 11111 Page 1 of 2 WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 In Canada: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1 L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1 -877 -BACKFLOW (1-877-222-5356) • Website: http://www.zurn.com (7 aw 20 N 0 15 w U) 10 U) W IX L 5 FLOW CHARACTERISTICS MODEL 975XL 314", 1", 1 114", 1 112" & 2" (STANDARD & METRIC) FLOW RATES (1/s) 1.26 2.52 3.8 5.0 32 63 95 126 158 TYPICAL INSTALLATION 20 1112 137 x 1 1/4" (32mm) (40m to 15 z" (50mm) 103 of W 10 69 co w 35 a 50 50 100 150 200 250 FLOW RATES (GPM) O Rated Flow (Established by approval agencies) Local codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. CENTRAL STATION ALARM PANEL BATTERY MONITOR 12" MIN. 30" MAX. AIR GAP FITTING n FLOOR DRAIN DIRECTION OF FLOW INDOOR INSTALLATION ('Shown w/ optional BMS) PROTECTIVE ENCLOSURE OPTIONAL AIR GAP WATER METER 1 DRAIN DIRECTION OF FLOW INLET SHUT-OFF OUTDOOR INSTALLATION 12" MIN 30" MA) SPECIFICATIONS The Reduced Pressure Principle Backflow Preventer shall be ASSES Listed 1013, rated to 180°F and supplied with full port ball valves. The main body and access covers shall be bronze (ASTM B 584), the seat ring and all internal polymers shall be NSF® Listed NorylTM and the seat disc elastomers shall be silicone. The first and second checks shall be accessible for maintenance without removing the relief valve or the entire device from the line. If installed indoors, the installation shall be supplied with an air gap adapter and integral monitor switch. The Reduced Pressure Principle Backflow Preventer shall be a WILKINS Model 975XL. WILKINS a turn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone: 9051405-8272 Fax:905/405-1292 Product Support Help Line: 1 -877 -BACKFLOW (1-877-222-5356) • Website: http://www.zurn.com Page 2 of 2 Capacity thru Schedule 40 Pipe Pipe size 5 ft/sec 7.5 ft/sec 10ft/sec /sec 15 ft/sec 1/8" 1 1 2 3 1/4" 2 2 3 5 3/8" 3 4 6 9 1/2" 1 5 7 9 1 14 3/4" 8 12 17 25 1" 13 20 27 40 11/4" 23 35 47 70 1 1/2" 32 48 63 95 2" 1 52 78 1 105 1 167 PROTECTIVE ENCLOSURE OPTIONAL AIR GAP WATER METER 1 DRAIN DIRECTION OF FLOW INLET SHUT-OFF OUTDOOR INSTALLATION 12" MIN 30" MA) SPECIFICATIONS The Reduced Pressure Principle Backflow Preventer shall be ASSES Listed 1013, rated to 180°F and supplied with full port ball valves. The main body and access covers shall be bronze (ASTM B 584), the seat ring and all internal polymers shall be NSF® Listed NorylTM and the seat disc elastomers shall be silicone. The first and second checks shall be accessible for maintenance without removing the relief valve or the entire device from the line. If installed indoors, the installation shall be supplied with an air gap adapter and integral monitor switch. The Reduced Pressure Principle Backflow Preventer shall be a WILKINS Model 975XL. WILKINS a turn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone: 9051405-8272 Fax:905/405-1292 Product Support Help Line: 1 -877 -BACKFLOW (1-877-222-5356) • Website: http://www.zurn.com Page 2 of 2 /J,,AMTROL. FIRE=X=TROL@ M LIUNNel.I Ivn HARGING ALVE MODELS: t FPT-1-C FPT-5-C FPT-12-C SYSTEM CONNECTION B CHARGING _ VALVE MODELS: FPT-20V C FPT-30V C A FPT-42V-C FPT-60V-C FPT-70V C C PT Series, Fire Protection Expansion Tanks(ASME) 175 PSI Working Pressure In -Line Models Model No. Tank Vol. Lit. Gal. A Height mm ins. B Diameter mm I ins. Sys. Conn. ins. Ship Wt. kg lbs. FPT-1-C 5.7 1.5 222 83/4 210 81/4 3/4 NPTF 7.3 16 FPT-5-C 8 2.1 264 103/8 254 10 3/4 NPTF 9.5 21 FPT-12-C 24 6.4 397 155/8 305 12 3/4 NPTF 15.4 36 Stand Models Model No. Tank Vol.Height Lit. Gal. A mm ins. B Diameter mm ins, C Dim. mm ins. Sys. Conn. ins. Ship Wt. kg I lbs FPT-20V-C 30 8.0 495 191/2 305 12 273 103/4 3/4 NPTF 23.6 52 FPT-30V-C 53 14.0 486 191/8 419 161/4 324 123/4 3/4 NPTF 44 97 FPT-42V-C 66 17.5 616 241/4 419 161/4 324 123/4 3/4 NPTF 52.7 116 FPT-60V-C 95 25.0 838 33 419 161/4 324 123/4 3/4 NPTF 70 154 FPT-70V-C 129 34.0 1054 411/2 419 161/4 324 123/4 3/4 NPTF 90 197 FPT-80V-C 200 53.0 908 353/4 610 24 406 16 11/4 NPTF 114 251 FPT-120V-C 250 66.0 1111 433/4 610 24 406 16 11/4 NPTF .127.6 281 FPT-18OV-C 292 77.0 1235 1 485/8 610 24 406 16 11/4 NPTF 160.3 353 FPT-21OV-C 341 90.0 1410 1 551/2 1 610 24 406 16 11/4 NPTF 173.4 382 Constructed per ASME Code Section VIII, Division 1. All dimensions and weights are approximate. B Standard Construction -111 CHARGING System Connection Stainless Steel -"VALVE High -Performance Rubber Compound Liner Material Polypropylene MODELS: Steel Coating FPT Red FPT-80V-C With or Without Antifreeze Per NFPA 13 A FPT-12OV C FPT-180V-C FPT-210V-C srsTs CONNECTIOruN I� C Job Name Location Maximum Operating Conditions Operating Temperature -20°F (-29°C) to 200°F (93°C) 1 M Working Pressure 175 PSIG (12 bar) Specifications APPROVED Description Standard Construction Standard Facto Pre -charge 25 PSIG 1.7 bar System Connection Stainless Steel Diaphragm Material High -Performance Rubber Compound Liner Material Polypropylene Shell Steel Coating FPT Red Fluid Compatibility With or Without Antifreeze Per NFPA 13 Contractor Contractor P.O. No. Sales Representative Model No. Ordered Engineer Rev. 04/11 Submittal data sheets can ONLY be ordered as a "Submittal Data Sheet Pack", using MC# 4400. They are not available to order on an P/N 4400-050 individual basis, however each data sheet is available on the AMTROL Web Site and can be downloaded and printed for use as needed. For the most undated technical specifications. olease download sheet at www.amtrol.com 50 /IwAMTROL. SYSTEM CONNECTION F 1— B ICHARGING ;� VALVE MODELS: A FPT-1 FPT-5 FPT-12 I I �SYSTEM CONNECTION j_ CHARGING VALVE MODELS: FPT-20V FPT-30V A FPT-42V FPT-60V FPT-70V . C — F1RE=X=TR0L@ FPT Series, Fire Protection Expansion Tanks(Non-ASME) . 175 PSI Working Pressure Non-ASME In -Line Models Model No. Tank Vol. Lit I Gal. A Height mm I ins. BS Diameter mm ins. Conn. ins. hip Wt. kg lbs. FPT-1 5.7 1.5 222 83/4 210 8'/4 3/4 NPTF 7.3 16 FPT-5 8 2.1 264 103/8 254 10 3/4 NPTF 9.5 21 FPT-12 24 6.4 397 155/e 305 12 3/a NPTF .15.4 36 Non-ASME Stand Models Model No. Tank Vol. Lit. I Gal. A Height mm I ins. B Diameter mm ins. C Dim. mm ins. Sys. Conn. ins. Ship Wt. kg I lbs FPT-20V 30 8.0 495 191/2 305 12 273 103/4 3/4 NPTF 23.6 52 FPT-30V 53 14.0 486 191/8 419 161/4 324 123/4 3/4 NPTF 44 97 FPT-42V 66 17.5 616 241/4 419 161/4 324 123/4 3/4 NPTF 52.7 116 FPT-60V 95 25.0 838 33 419 161/4 324 123/4 3/4 NPTF 70 154 FPT-70V 129 34.0 1054 411/2 419 161/4 324 123/4 3/4 NPTF 90 197 FPT-80V 200 53.0 908 353/4 610 24 406 16 11/4 NPTF 114 251 FPT-120V 250 66.0 1111 433/4 610 24 406 16 11/4 NPTF 127.6 281 FPT-180V 292 77.0 1235 4854 610 24 406 16 11/4 NPTF 160.3 353 FPT-210V 341 1 0.0 1410 551/2 610 24 406 16 11/4 NPTF 173.4 382 All dimensions and weights are approximate. BCHARGING Standard Construction Standard Facto Pre -charge 25 PSIG 1.7 bar System Connection Stainless Steel Diaphragm Material VALVE Liner Material Polypropylene Shell Steel Coating MODELS: Fluid Compatibility With or Without Antifreeze Per NFPA 13 FPT-80V A FPT-120V FPT-180V FPT-210V srsTEM? CONNECTION !*--owl Job Name Location Engineer Maximum Operating Conditions Operating Temperature -20°F (-29°C) to 200°F (93°C) f M Working Pressure 175 PSIG (12 bar) Specifications. APPROVED Description Standard Construction Standard Facto Pre -charge 25 PSIG 1.7 bar System Connection Stainless Steel Diaphragm Material High -Performance Rubber Compound Liner Material Polypropylene Shell Steel Coating FPT Red Fluid Compatibility With or Without Antifreeze Per NFPA 13 Contractor Contractor P.O. No. Sales Representative Model No. Ordered Rev. 04/11 Submittal data sheets can ONLY be ordered as a "Submittal Data Sheet Pack', using MC# 4400. They are not available to order on an 51 P/N 4400-051 individual basis, however each data sheet is available on the AMTROL Web Site and can be downloaded and printed for use as needed. For the most uodated technical soecifications. Dlease download sheet at www.amtrol.com INSTALLATION, OPERATION & SERVICE INSTRUCTIONS FAVL FIRE-X-TROL° FPT-1(C) THROUGH FPT-210V(C) 1400 Division Road, West Warwick, RI 02893 A T: 401.884.6300 A F: 401.885.2567 A www.amtrol.com AMTROL® Wet Pipe Sprinkler System Expansion Chamber QTHIS IS A SAFETY ALERT SYMBOL. IT IS USED TO ALERT YOU TO POTENTIAL PERSONAL INJURY AND OTHER HAZARDS. OBEY ALL SAFETY MESSAGES THAT FOLLOW THIS SYMBOL TO REDUCE THE RISK OF POSSIBLE INJURY AS WELL AS PROPERTY DAMAGE. AWARNING READ CAREFULLY THE PRODUCT INSTALLATION, OPERATING AND MAINTENANCE MANUAL. FAILURE TO FOLLOW THE INSTRUCTIONS AND WARNINGS IN THE MANUAL MAY RESULT IN SERIOUS OR FATAL INJURY AND/OR PROPERTY DAMAGE, AND WILL VOID THE PRODUCT WARRANTY. THIS PRODUCT MUST BE INSTALLED BY A QUALIFIED PROFESSIONAL. FOLLOW ALL APPLICABLE LOCAL AND STATE CODES AND REGULATIONS, IN THE ABSENCE OF SUCH CODES, FOLLOW THE CURRENT EDITIONS OF THE NATIONAL PLUMBING CODE AND NATIONAL ELECTRIC CODE, AS APPLICABLE. AWARNING Excessive pressure can cause tank to explode. Exercise care when filling a tank with air so the pressure does not exceed that required or does not exceed the working pressure of the tank as stamped on the nameplate. Failure to follow these instructions will result in serious personal injury or death and property damage. AWARNING This Product, like most Products under pressure, may over time corrode. weaken and burst or explode, causing serious or fatal injury, leaking or flooding and/or property damage. To minimize risk, a licensed professional must install and periodically inspect and service the Product. A drip pan connected to an adequate drain must be installed if leaking or flooding could cause property damage. Do not locate in an area where leakage of the tank or connections could cause property damage to the area adjacent to the appliance or to lower floors of the structure. AWARNING EXPLOSION OR RUPTURE HAZARD A relief valve must be installed to prevent pressure in excess of local code requirement or maximum working pressure designated in the Product Manual, whichever is less. Do not expose Product to freezing temperatures or temperatures in excess of 200° F. U` FM APPROVED AWARNING Do not adjust the pre -charge or re -pressure this Product except for any adjustments required at the time of initial installation, especially if Product corroded, damaged or with diminished integrity. Adjustments to pre -charge must be done at ambient temperature only. Failure to properly size the Product or follow these instructions may result in excessive strain on the system lead to Product failure, serious or fatal personal injury, leakage and/or property damage. No e• Please read the entire owner's manual and installation instructions before installing your new AMTROL product. Save all documents and manuals for future reference. Note: Use proper safety equipment when installing. FAILURE TO FOLLOW THE WARNINGS AND INSTRUCTIONS HEREIN MAY RESULT IN SERIOUS OR FATAL PERSONAL INJURY AND/OR PROPERTY DAMAGE AND WILL VOID THE WARRANTY. Note: Inspect for shipping damage and notify freight carrier or store where purchased immediately if damage is present. To avoid risk of personal injury and property damage, if the product appears to be malfunctioning or shows signs of corrosion, call a qualified professional immediately. Current copies of the Product manual can be viewed at www.amtrol.com. Use proper safety equipment when installing. IAIMPORTMI GENERAL SAFETY INFORMATION - ADDITIONAL SPECIFIC SAFETY ALERTS APPEAR IN THE FOLLOWING INSTRUCTIONS. AWARNING CALIFORNIA PROPOSITION 65 WARNING: This product contains a chemical known by the State of California to cause cancer and to cause birth defects or other reproductive harm. (California Installer/Contractor - California law requires that this notice be given to consumer/end user of this product.) For more information: www.amtrol.com/prop65/htm. APPROVALS: UL® Listed and FM APPROVED for use with Fire Protection antifreeze systems per NFPA 13. THIS PRODUCT COMES WITH A LIMITED ONE (1) YEAR WARRANTY, SEE AMTROL'S LIMITED PRODUCT WARRANTY FOR DETAILS. Part #9017-123 (05/11) Proper FIRE-X-TROLO Location Operation 1. The FIRE-X-TROL® should be installed on the water supply line to 1. The FIRE-X-TROL® is installed in the supply line between the the unheated area at a point between the backflow preventer and fill backflow preventer and the fill cup connection. Its sealed -in air pre - cup connection (See Figure 1). charge chamber prevents water from entering it until the system 2. Once the FIRE-X-TROL® is installed, check the system for any pressure exceeds the pre -charge pressure. The FIRE-X-TROL® is leakage. Make repairs if necessary. precharged to 25 psig (1.7 bar). Pre -Installation 2. As the water/antifreeze solution temperature rises, expanded system 1. Visually inspect FIRE-X-TROL® for any damage. fluid enters the FIRE-X-TROL®'s non -corrosive reservoir. The pre - 2. Hydraulic system pressure must be at zero. charge air chamber absorbs the pressure increase, keeping system 3. Attach nitrogen or dry air (-50°F/-46°C dew point or lower) supply to pressure below maximum system rating. expansion chamber charging valve. 3. As the water/antifreeze temperature decreases, pressure in the air Heated area chamber forces system fluid back into the system. AWARNING Do not use Oxygen -Explosive. 4. In antifreeze systems, this sequence allows the system antifreeze percentage to stay constant. Additional supply of water/antifreeze AWARNING Pre -charge ordryair(-50°F/-a6°C is not needed to replace fluid that would have escaped through a relief valve. dew point or lower) 4. Pre -charge to 2 psig (0.14 bar) below system static pressure at tank Maintenance location. 1. Sprinkler system must be maintained and inspected per NFPA 25. AWARNING Never pre -charge below 25% of the system maximum rated pressure. 5. Remove charging hose. Carefully test charging valve for leakage. 6. Replace plastic cap. IAWARNINI:Gl Protect against freezing temperatures. Can cause damage and/or product failure. AWARNING Isolate expansion chamber during system hydro test. Figure 1 Fill cup or filling connection Backflow preventer + with controlvalves _ Water 1 ' supply Heated area Drain valve tUnheated area FIRE-X-TROL® FPT-1-C & FPT 5-C & FPT-12-C Fill cup or filling connection Backflow preventer 1 with Controllvalves Water 1 supply FIRE-X-TROL® t FPT-20V-C Drain through valve FPT 21 OV -C - Unheated area ' Heated area Products covered: all Products manufactured by AMTROL Inc. ("AMTROL") . This warranty cannot be transferred — it is extended only to the original Purchaser or First User of the Product. By accepting and keeping this Product you agree to all of the warranty terms and limitations of liability described below. IMPORTANT WARNING — READ CAREFULLY THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS MANUAL ("MANUAL'S to avoid serious personal injury and/or property damage and to ensure safe use and proper care of this product Who Receives AMTROL's Product Warranty All purchasers or first users of the new Product. The Warranty is non -transferable. What is covered by this Warranty AMTROL warrants to the purchaser or first user of the new Product that at the time of manufacture, the Product is free from defects in material and workmanship. Any warranty claim must be made within one (1) year unless another time period is set forth in the Manual, measured from the time the Product was purchased. What AMTROL Will Do If You Have a Covered Warranty Claim In the event of a breach of the foregoing warranty, AMTROL will at its option either make repairs to correct any defect in material or workmanship or supply and ship either new or used replacement parts or products. AMTROL will not accept any claims for labor or other costs. What This Warranty Does Not Cover - Exclusions and Limitations This Warranty does not cover any failure or problem unless it was caused by a defect in material or workmanship. In addition, this Warranty shall not apply: • if the Product is not correctly installed, operated, repaired or maintained as described in the Manual provided with the Product; • to any failure or malfunction resulting from abuse (including freezing); improper or negligent: handling, shipping (by anyone other than AMTROL), storage, use, operation, accident; or alteration, lightning, flood or any other environmental condition; • to any failure or problem resulting from the use of the Product for any purpose other than those specified in the accompanying Manual or alteration of any part of the product; • this Warranty does not cover labor costs, shipping charges, service charges, delivery expenses, administrative fees or any costs incurred in removing or reinstalling the Product; this Warranty does not cover any claims submitted to AMTROL or an AMTROL-authorized distributor or retailer more than 30 days after expiration of the applicable warranty time period described in this Warranty; • this Warranty also does not cover repair or replacement costs not authorized in advance by AMTROL. Additional Warranty Limitations ALL IMPLIED WARRANTIES, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE SPECIFICALLY DISCLAIMED. Limitations of Remedies THE REMEDIES CONTAINED IN THIS WARRANTY ARE THE PURCHASER'S OR FIRST USER'S EXCLUSIVE REMEDIES. IN NO CIRCUMSTANCES WILL AMTROL BE LIABLE FOR MORE THAN, AND PURCHASER -FIRST USER'S REMEDIES SHALL NOT EXCEED, THE PRICE PAID FOR THE PRODUCT. IN NO CASE SHALL AMTROL BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, WHETHER RESULTING FROM NON-DELIVERY OR FROM THE USE, MISUSE, OR INABILITY TO USE THE PRODUCT OR FROM DEFECTS IN THE PRODUCT OR FROM AMTROUS OWN NEGLIGENCE OR OTHER TORT. This exclusion applies regardless of whether such damages are sought for breach of warranty, breach of contract, negligence, strict liability, in tort or under any other legal theory. Such damages include, but are not limited to, inconvenience, loss or damage to property, mold, loss of profits, loss of savings or revenue, loss of use of the Products or any associated equipment, facilities, buildings or services, downtime, and the claims of third parties including customers. What To Do If You Have a Problem Covered By This Warranty Any covered Warranty service must be authorized by AMTROL. Contact the person from whom you purchased the Product, who must receive authorization from an AMTROL distributor or AMTROL. If you do not receive a prompt response, call AMTROL directly at 877-517-9673. Notice of a Warranty claim should be submitted by the authorized distributor to AMTROL at the following address: AMTROL Inc., Warranty Claim Dept. 1400 Division Road, West Warwick, RI 02893 Before AMTROL determines to provide any replacement part or Product, it may as a pre -condition to making such a determination require that the warranty claimant ship the Product, postage prepaid to an authorized AMTROL distributor, or to AMTROL and provide proof of purchase evidenced by the original sales receipt or Product registration. Replacement Product Warranty In case of replacement of a Product or any component part, AMTROL reserves the right to make changes in the design, construction, or material of the substitute components or products, which shall be subject to all of the terms and limitations of this Warranty, except that the applicable warranty periods shall be reduced by the amount of time the warranty claimant owned the product prior to submitting notification of the warranty claim. • /�- Revised 01/11 AI MOL 1400 Division Road, West Warwick, RI 02893 A T. 401.884.6300 A F: 401.885.2567 A www.amtrol.corn AMTROL, AMTROL logo, and FIRE-X-TROL are registered trademarks of AMTROL Inc. and affiliates in the U.S. and elsewhere. All rights reserved. Part #: 9017-123 (05/11) , /A&IML AMTROL. 1400 Division Road, West Warwick, RI 02893 ♦ T: 401.884.6300 F: 401.885.2567 ♦ www.amtrol.com AMTROL, AMTROL logo, and FIRE-X-TROL are registered trademarks of AMTROL Inc. and affiliates in the U.S. and elsewhere. All rights reserved. Part #: 9017-123 (05/11) SIZING THE FIRE-X-TROLO � WATER i Use the reliable FIRE-X-TROL® to accommodate the expanded volume of water in your Wet Sprinkler System! The FIRE-X-TROL® gives you the confidence of installing a UL listed expansion chamber for use in water with your wet sprinkler system. The Fire -X -Trot® is also designed, constructed and tested to ASME Section VIII Division 1 Standards. The -sizing chart provided can be used to select the appropriate FIRE-X-TROL®.for your water wet pipe sprinkler system: ------------------------------------------------------------------------------------- Example for determining FIRE-X-TROL`� expansion chamber size for Water Service: _ System Volume (gal.): 30 Gallons. - System. Pressure: 80 psig ' Under these service conditions, a model FPT-5 (C ) would be selected., - 1 •Please contact AMTROL. Technical Services for`Fire-X-Troll vessel sizing for parameters not found on chart: Assumptions: 175 psig (12 bar) Maximum Working Pressure, 100°F (37.7°C) change in temperature (based on 40°F/,,4.4°C to 140°F/60°C), expansion tank precharge to System Static Pressure. -Corporate Headquarters 1400 Division Road, West Warwick, RI 02893 • Tel: 401-884-6300 • Fax: 401-884-5276 MC# 10048 REV B (03/06) . Water System Pressure (psig) , 40 50 60 70 60 90 100 110 120 130 140 150 10 `, 38 20 ;. FPT. 5, C 7& 30 r, 113 ''% 40 151 N cm 50 189 d 60 227 , M E 70 264 80 302 < ' > 90FPT 12-C 340 E 10o a :�' 378 3 d N 110416 3UV `C; 415 co �+ 120 454 CO. 130;' FPT2�V C 491 v 140 ;, FET 42V -c 529 567 " 2.7 1 3.4 4.0 4.8 5.5 6.2 7 7.5 8.3 9 9.6 10.5 System Pressure (bar) 1 •Please contact AMTROL. Technical Services for`Fire-X-Troll vessel sizing for parameters not found on chart: Assumptions: 175 psig (12 bar) Maximum Working Pressure, 100°F (37.7°C) change in temperature (based on 40°F/,,4.4°C to 140°F/60°C), expansion tank precharge to System Static Pressure. -Corporate Headquarters 1400 Division Road, West Warwick, RI 02893 • Tel: 401-884-6300 • Fax: 401-884-5276 MC# 10048 REV B (03/06) . • Accurate Factory Pre -Mix - Complies with NFPA guidelines • System Compatible - Certified by NSF for use with BlazeMaster'm CPVC • Non -Toxic' - FDA Classification of Generally Regarded as Safe (G.R.A.S.) to humans and animals 0010 SYSTEM COMPATIBLE „� FireFighter GL48 is a non-toxic, glycerine -based antifreeze for use in all types of wet fire sprinkler systems, including CPVC. FireFighter GL48 is factory pre -mixed to NFPA guidelines of a 48% glycerine solution. All fire sprinkler systems utilizing FireFighter GL48 should conform to local, state, and NFPA requirements. The use of antifreeze within these systems should also conform to NFPA requirements. Installation: • Evacuate all water from system and drain drops according to NFPA requirements. • FireFighter GL48 should be tested prior to introduction into the system. • Do not dilute or add concentrate to FireFighter GL48 • After filling the system, follow NFPA guidelines for testing the antifreeze. Fluid samples should be tested from a minimum of a high point and low point, and should be comparable to both each other and to the sample of the fluid tested prior to introduction into the system. • NFPA requires a tag to be affixed to the riser indicating the date tested or replaced, the type and concentration by volume of fluid used, system capacity (in volume), contractor name and license number, and a statement indicating if the entire system was drained and replaced with antifreeze. Tags are available free of charge from Noble Company or your local FireFighter distributor. , System Protection: FireFighter GL48 FBe Factory Pre -Min •,•,•„„am, % of FireFighter GL48 Freeze Point Flow Point Burst Point Specific Gravity @77•F / 25•C 100 -15°F -25°F =50°F 1.137 Freeze Point is the temperature where the first ice crystal forms in the fluid. Burst Point is the temperature where the fluid is solid, expanding and bursting the vessel. FireFighter Accessories: The Palm Abbe refractometer is fast, convenient, and easy to use. Simply place a drop or two of fluid in the titanium well and press a button. The custom-designed microprocessor is temperature compensating and delivers readings for glycerine and propylene glycol for both percentage by volume and freeze point. Accuracy of +/- .10 %. The Hydrometer measures the specific gravity of propylene glycol and glycerine. Conversion tables allow the user to interpolate readings for percentage of concentration by volume and freeze point. Includes graduated cylinder. System Requirements, Limitations & Cautions: All fire protection sprinkler systems that use FireFighter GL48 should conform to local, state and NFPA requirements. The use of antifreeze within these systems should also conform to NFPA requirements. Use of antifreeze solutions should also be in conformance with any state or local health codes. Please contact your local health authorities if you have any questions concerning the codes in your area. Chemicals which compose FireFighter GL48 can break down over time. NFPA 25 requires that the freezing point of the system should be tested at least once a year. Periodic testing of systems is critical to maintaining the proper concentration and freeze point of the fluid. Leaks, pressure surges, and temperature changes to the system can cause antifreeze to flow out of the system or water to flow into the system changing the freeze temperature. Hydraulic Overview y _ ` 'Job Number: CTS1 w ` Re ortDescri tion: NFPA 13D - 2 Heads Job •'Design J. Number . • - Engineer CTS1 Z, T Ewin' ` Job Nem,: • • Phone' • FAX Cates Residence ' 4 ` k { Slate CergflcsdonlLi—se Number Tiger Lily Lane • ' • C16-966369 Forest Ranch, CA 95942 "' 'a Butte County Building Dept. Address? -• • - •. „ - Job SBe/SWMUT . A.P.N. 056-280-070 - System Density - ,y• 0.050gpm/ft2 1 - v� �; 3_ - Area of Appicadon + 512.00ft2 - . Moat Demanding SprinMer Data t _ - �. Hose Streams 4.9 K -Factor. 13.00 at 7.039 0.00 Cosemge Per Spdnlder ., ^ - • Number Df Sprinklers Ua dated- 256.00ft2 .a %2 ' System Prei,ure Dema. .. ^ . .. - /.- ^ _J ,Syarom Fbr tbma. _ • - , 53.531 32.28 Total Demand 32.28 @ 53.531 ''. - \ -.., Pressure Reeult a -• +6.436 (10.7%) Supplies' Check Point Gauges Node . Name ' ' Flow(nom) Hose Flow(gom) Static(psi) Residual(psi) Identifier Pressure(psi) K-Factor(K) Flow m 1 'Water Supply 32.00 ' 62.0007 60.000 r �' Piping Plan . " Y. ; Mter Supply at Node 1 (32.00, 0. 00, 62.000, 60.000) , } ' • - •- ,. � w , � 100, •! � ,- � 90 80 70 ' Static Pressure 62.000 ` 60 �. € 2.00 @ 60.00 - ' t 50 32.28 @i 53.531 3 a 40 System demand curve 30 10 • 0 IMMMM111 I I I I I I I I'l I 1 1] 1 1 1 111 11 1 0714 28 42 56 r 70 r `. 21 35 49 63 r - �� - • * Water flow, gpm ©M E.P.CAD, Inc. AutoSPRINK® 12 v12.0.61.0 - 6/14/2017 3:04:55PM Page >1 f Hydraulic Summary. t , • Job NUmber:,CTS1 Re ort Descri tion: NFPA 13D - 2 Heads Job Job Number - - _ De sign Engineer CTS1 - J. T. Ewin Job Name: - _ Cates Residence ', State CertifisetioMkanse Number - C16-966369 s Address - Tiger Lily Lane', .. - ' , .AHJ Butte County Building Dept. Md.. 2 -- _- - Job She/Building „_� ^ •[- •' - Forest Ranch, CA 95947 -p Address 3 .. .. . Drawing Name • -. _ _ f _ A.P.N. 056-280-070 4 '' Piping Plan System' Remote Area (s) Mast Demanding Sprinkler Data Occupanry Job Sump - - 4.9 K -Factor 13.00 at 7.039 Residential Manually Flowing How Amwa once Al Source . - -. ` ,Denstty O , Area of Application -,r 0.00 _ 0.050gpm/ft' • 512.00ft' AOdiUonal Mow Suppmea- - A - - Number Of Sprinklers Calwiated • Coverage Per Spdnider - 4` Node Flow(gpml G 2 256.00ft' Hose At Node 6 5.00 _ � - ' Adjacent To Most Remote Area AutaPeak Resume: Pressure Far Remote Araeis� suss - it !. - • A•t `_ y ` Total How Sire - — - � - i • - ,5.00 " • _ ' `, `V ' System Flow DemaM . TotalMt., Required including Hew Aff--) "'� 32.28 32.28 - f - - Y , Maximum Pressure unbalance In Leaps • '" - - 0.000 _ • x.. •` „ 1• Maximm Velocity Alba,, Ground• h' .� - -11.31 between nodes 4 and 5 '• ; - - ; - t MaxMum Velocity Under Ground ' •- -' - 12.55 between nodes 1 and 2 • h ? , " - -• Volume capacity of VAd Pipes - Votume capacity of D7 Pipes 18.07ga1 Supplies Hose Flow I Static Residual Flow Available Total Demand Required Margin, : Node Name' m (psi)(psi)C° m (psi)_ ' m (psi). ) ,Safety si . 1 I Water Supply I 1: 62.000 I 60.000 32.00 I 59.967 I 32.28 I, 53M1 ' ( 6.436' cC is Contractor Con --, Number ' C16-9663.69 , Came Nem. A. Gillespie x Unrect Tge ' M Name of Connector:' _ A.G. Plumbing -. - , s Phone '(530) 356-4797 - ' Y r Extension ` . Address I 3848 Thomason Trail ` • a • FAX ' +• (530) 748-0143 9 _ Address z Redding; CA 96002 _ .y • E- 11 • .. - acg870@yahoo.com . .- - AOArewS - Mb -SH. - « www.agplumbingredding.'com - L © M.E.P.CAD, Inc. AutoSPRINK@ 12 v12.0.61.0 6/14/2017. 3:04:57PM Page 2 Job Number: CTS1 RAnnrf nocrrinfinn- NFPG 11r1 -9 W—rfc Water Supply at Node 1 100 - 009080 go --- 8 70 Static Pressure 62.000 60 32.00 @ 60.000 .N CL 32.28 @ 53.531 50— in N `1 CL 40-- 30 System demand curve 20 10 0 0 7 14 21 28 35 42 49 56 63 70 Water flow, gpm Hy@ dl. G -Ph Water Supply at Node 1 slauo: N.- 62.000 ReslE al: Pre - 60.000 @ 32.00 Aveuaele Pressure al T — sl Test 59.967 @ 32.28 sr—Ge M 53.531 @ 32.28 Srerem DemvM PaC�rO lloso Nbwanss of Sourro) . 53.531 @ 32.28 &- U M.E.P.GAD, Inc. M AUtoSPRINK® 12 02.0.61.0 6/14/2017 3:04:58PM Page 3 IIISummary Of Outflowing Devices Job Number: CTS1 Report Description: NFPA 13D - 2 Heads Actual Flow Device m Minimum Flow m K -Factor K(psi) Pressure Hose 6 5.00 5.00 0 37.722 Sprinkler 101 14.28 13.00 4.9 8.497 b Sprinkler 102 13.00 13.00 4.9 7.039 r* Most Demanding Sprinkler Data &- © M. E. P. CAD, Inc. 9.jjAutoSPRINK® 12 02.0.61.0 6/14/2017 3:04:58PM Page 4 Node Analysis Job Number: CTS1 Renort Descrintiore NFPA 13D - 2 Heads Node Elevation Foot Fittings Pressure si Dischar e m 1 -3'-0 S 53.531 32.28 6 1'-6'/2 Hose_ 37.722 5.00 101 8'-10Y2 S r(-8.497) 8.497 14.28 102 11'-3'/2 Spr( 7.039) 7.039 13.00 2 -3'-0 WMV(-4.295) 48.856 3 -3'-0 cplg 1'-0 40.796 4 0'-0Yz 38.836 5 1'-6'/z 1(5_9) 37.775 7 8'-6 E(T-O) 14.575 8 8'-6 T 5'-0 13.478 9 9'-5 1 T(5' -O), Tr(1'-0) 8.738 10 9'-5 T 5'-0 8.735 L © M. E. P. CAD, Inc. Auto SPRINK® 12 v12.0.61.0 6/14/2017• 3:04:59PM Page 5 1 Hydraulic Analysis Job Number: CTS1 P. -t n-rM - mr:PA 1zn - 7 uo„i. Pipe Type Diameter Flow Velocity. HWC Friction Loss LengthPressure Downstream Upstream Elevation Discharge K -Factor - Pt Pn , Fittings Eq. Length Summary Total Length - ®••••• Route 1 DR 1.1010 13.00 4.38 150 0.030666 10'-3 Pf 0.897 102 9 11'-3% 9'-5 13.00 4.9 7.039 8.738 Sprinkler, 2E T-0 , T(5'-0) 19'-0 29'-3 Pe Pv, 0.803 BL 1.1010 15.30 5.16 _ 150 0.041451 68'-8 Pf 4.339 9 8 9'-5 8'-6 2.30 8.738 13.478 Flow (q) from Route 2 5Tr(1'-0), 3E(7' -O), 2T(5'-0) 36'-0 104'-8 Pe Pv 0.402 BL 1.1010 27.28 9.19 150 0.120859 2'-1 Pf 1.096 8 7 8'-6 8'-6 11.98 13.478 14.575 Flow (q) from Route 4 E T-0 7'-0 9'-1 Pe Pv FR 1.0800 27.28 9.56 120 0.200582 8'-10 Pf 20.177 7 5 8'-6 1'-6% 14.575 37.775 sCV(5'-9), f(-3.000), E(2' -3'h), BFP -12.634 , T 5'-9 13'-10 22'-8 Pe Pv 3.024 FR 1.0800 32.28 _ 11.31 120 0.273836 V-6 Pf 0.411 5 4 V-6'/: 0'-0'/z 5.00 37.775 38.836 Flow (q) from Route 3 V-6 Pe Pv . 0.650 UG 1.2450 32.28 8.51 150 0.090679 6-2 Pf 0.648 4 3 0'-0'h -3'-0 38.836 40.796 UE, c Ig(1'-0) V-0 7'-2 Pe Pv 1.311 UG 1.3940 32.28 6.79 150 0.052290 64'-0 Pf 8.059 3 2 -3'-0 4-0 40.796 48.856 E(8' -O), WMV(-4.295) 8'-0 72'-0 Pe Pv UG 1.0250 32.28 12.55 150 0.233752 20'-0 Pf 4.675 2 1 4-0 -3'-0 48.856 53.531 Water Supply 20'-0 Pe Pv 0.00 Hose Allowance At Source 1 32.28 Gib ••••• Route 2••••• DR 1.1010 14.28 4.81 150 0.036501 V-11'/: Pf 0:474 101 10 8'-10'/2 9'-5 14.28 4.9 8.497 8.735 Sprinkler, E 7'-0 , T(5'-0) 12'-0 Pe 12'-11'/: Pv -0.236 BL 1.1010 2.30 0.78 150 0.001244 1'-5'/z Pf .0.003 10 9 9'-5 9'-5 8.735 8.738 Tr(1'-0) V-0 Pe 2'-5'/: Pv -0.000 490•••••Route 3••••• FR 1.0800 5.00 1.75 120 0.008689 0'-4'/2 Pf 0.053 6 5 V-6'% 1'-6'% 5.00 _ 37.722 37.775 Hose T(5'-9) 5'-9 Pe 6'-1'/2 Pv e•••••Route 4••••• BL 1.1010 11.98 4.04 150 0.026379 91'-7 Pf 4.342 10 8 _ 9'-5 - 8'-6 8.735 13.478 7E(7' -O), 9Tr(1'-0), 3T(5'-0) 73'-0 Pe 164'-7 Pv 0.402 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) / .- Actual Inside Diameter l Schedule 40 Steel Pipe Inside Diameter k \ 4.87 /1 =Factor C Value Multiplier Value Of C 100 130 140 Multiplying Factor 0.713 1.16 1.33 •1.51 150 - L; ky iw.t.r.LAu, mc. 0AutoS1'KINKU 12 V12.0.61.0 6/14/2017 3:05:OOPM Page 6 •���� Hydraulic Analysis' ; ' Job Number: CTS1 .: r• '' Report Description: NFPA 13D - 2 Heads Pipe Type - Diameter Flow Velocity HWC Friction Loss ,. Length Pressure Downstream . - Elevation • Discharge- -Factor a •. Pty Pn Fittings, Eq. Length ' (Summary - Upstream 4K Total Length .Pipe Type. Legend -'Units Legend Fittings Legend ' AO Arm -Over ,-Diameter 'Inch ALV,' Alarm Valve':. BL • Branch Line '. a ElevationFoot r , AngV Angle Valve CM Cross Main Flow gpm �. !'� b Bushing DN .Drain ' • x-agp Discharge m ` BaIV Ball Valve DR Drop_ Velocity fps BFP Backflow Preventer DY Dynamic Pressure= psi `Y r� ` • BV + _,. Butterfly Valve ^ FM `'Feed Main Length Foot t ' ' • rt i' C - % Cross Flow Turn 90° FR Feed Riser _ Friction Loss ' ' psi/Foot. *. cplg Coupling . ' MS - Miscellaneous a ' _ HWC Hazen -Williams Constant Cr Cross Run OR' utrigger • Ot P Total pressure at a point i n a pipe ' , CV "Check Valve RN Riser Nipple ': Pn Normal pressure at a point in a pipe DeIV Deluge Valve SP Sprig J Pf Pressure loss due to friction between points +3`' - DPV Dry Pipe Valve ST Stand PipeE Pe Pressure due to elevation difference between indicated points 90° Elbow UG Underground Pv ' Velocity pressure at a point in a pipe - EE 45° Elbow Eel 11%* Elbow �� - ,• • , Eel 22'/z Elbow .f Flow Device - a - 'fd . Flex Drop r FDC . Fire Department Connection s t fE 90° FireLock(TM) Elbow-' fEE ,. 45° FireLock(TM) Elbow fig Flange FN. Floating Node fT FireLock(TM) Tee g ` Gauge GloV ' Globe Valve GV Gate Valve Ho 'Hose Hose Hose - " HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee « Noz Nozzle ' - P1 - ..Pump In P2, Pump Out PIV Post Indicating Valve PO Pipe Outlet " PRV . Pressure Reducing Valve ' PrV - Pressure Relief Valve " ' - red Reducer/Adapter • S Supply .. . • . • '+ �' F , sCV Swing Check Valve a Spr Sprinkler St Strainer . ' • T'' Tee Flow Turn 90° _ Tr. Tee Run U ' Union" ' WirF ' Wirsbo J - - •,� WMV Water Meter Valve i Z,' Cap Al ©M.E.P.CAD, Inc. - AutoSPRINKG 12 x12.0.61.0 l "' 6/14/2017. Page 7 �3:05:OOPM