Loading...
HomeMy WebLinkAboutB18-0486 047-330-028BUTTE COUNTY 'DEPARTMENT OF DEVELOPMENT SERVICES INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspections is 3pm) Development Services cannot guarantee inspections on the date requested Office: 530.538.7601 Fax: 530.538.7785 www.ButteCounty.net/dds Permit No: B18-0486 Issued: 3/5/2018 APN: 047-330-028 Address: 4176 KEEFER RD, CHICO Owner: - MILLER BRADFORD L & DENICE Permit Type: SOLAR ROOF -RES Description: 11.02 kW Roof Mount Solar Array AREA 4 Flood "Gone: X (Unsh SRA Area: LRA SETBACKS for Zoning, AG. SRA. PW Front: Centerline of Road:, Rear: SRA: Street: AG: Interior Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING • r Inspection Type IVR INSP DATE Setbacks 131 Foundations / Footings 1 I 1 Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Signed Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 Blockin /Unde inin 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed Shearwall/B.W.P.-Interior 134 Shearwall/B.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 417 Manometer Test Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Plumbing Final 813 Fire Sprinkler Test or Final 702 Swimming Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 503 Pre -Plaster 507 Manufactured Homes Setbacks 131 Blockin /Unde inin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602. Skirting/Steps/Landings 610 Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: Length x Width: Insignia: t ,Finals Permit Final 802 Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test or Final 702 Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final FPROJECT FINALVP • *Project Final is a Certificate of Occupancy for (Residential Only) PERMITS BECOME NULL AND VOID I YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A I YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION r 1 v/DIRECTORY OF PLAN PAGES PROJECT DETAILS WNER IBRAD MILLER . DDRESS 4176 KEEFER ROAD CHICO. CA 95973 Ut LUIb L ALWUMIA HKt l UUt ED CODES 2016 CALIFORNIA ELECTRICAL CODE 2016 CALIFORNIA BUILDING CODE 2016 CALIFORNIA RESIDENTIAL CODE 2016 CALIFORNIA PLUMBING CODE 2016 CALIFORNIA MECHANICAL CODE 2016 CALIFORNIA ENERGY CODE WITH 2016 CA ENERGY EFFICIENCY STNDRD. OSHA 29 CFR 1910.269 UNDERWRITERS LABORATORIES (UL) STANDARDS .METHOD ASCE7_10 CONTRACTOR INFORMATION IY URBAN DESIGN SOLAR NO. 893826 (B, C46) S 2260 PARK AVENUE CHICO, CA 95928 (530) 345-0005 CTOR IRE SYSTEM DETAILS NG OF SYSTEM 111,020W VVI " PV -1 SCALE: NTS :R JULAK LUUt: Z7U000UA-UJ (38) REC SOLAR REC290TP2 (BLK) CONFIGURATION 1 STRING OF 12 MODULES 1 STRING OF 12 MODULES 1 STRING OF 14 MODULES ' )NNECTION LOAD -SIDE SITE SPECIFICATIONS SERVICE 120V/240V SPLIT PHASE MAIN 200A RATED BUSBAR 200A MAIN BREAKER TO BE DERATED TO 175A 60A PV TIE-IN BREAKER EXTREME ANNUAL MEAN -0°C A DENSITY DRY BULB TEMP. :.2% ANNUAL DRY DENSITY 40-C EXPOSURE CATEGORY aw�.-... 2 LOCALE PV -1 SCALE: NTS 1 CONSTRUCTION NOTES CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS 1 PRIOR TO INITIATING CONSTRUCTION. Y GV O CONTRACTOR SHALL REVIEW ALL MANUFACTURER 2 INSTALLATION DOCUMENTS PRIOR TO INITIATING CONSTRUCTION. z ALL EQUIPMENT SHALL BE LISTED BY THE U.L. (OR 3 EQUAL) AND LISTED FOR ITS SPECIFIC APPLICATION. 4 ALL EQUIPMENT SHALL BE RATED FOR THE ly ENVIRONMENT IN WHICH IT IS INSTALLED. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE 5 WITH THE MANUFACTURER'S INSTALLATION O INSTRUCTIONS. ACCESS TO ELECTRICAL COMPONENTS OVER 150 6 VOLTS TO GROUND SHALL BE RESTRICTED TO QUALIFIED PERSONNEL. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 ' 7 VOLTS AND 90°C WET ENVIRONMENT, UNLESS OTHERWISE NOTED. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND 8 CONDUITS ARE NOT SPECIFIED, CONTRACTOR SHALL ' (530) 321-9269 SIZE THEM ACCORDING TO APPLICABLE CODES. PV MODULES FRAMES SHALL BE BONDED TO RACKING 9 RAIL OR BARE COPPER G.E.C. PER THE MODULE MANUFACTURER'S LISTED INSTRUCTION SHEET. PV MODULES RACKING RAIL SHALL BE BONDED TO 10 BARE COPPER G.E.0 VIA WEEB LUG, ILSCO GBLADBT LAY -IN LUG, OR EQUIVALENT LISTED LUG. GROUNDING ELECTRODE CONDUCTOR (G.E.C) SHALL 11 BE CONTINUOUS AND/OR IRREVERSIBLY SPLICED ALL JUNCTION BOXES, COMBINER BOXES, AND 12 DISCONNECTS SHALL BE INSTALLED IN AN ACCESSIBLE LOCATION. WORKING SPACE AROUND ELECTRICAL EQUIPMENT 13 SHALL COMPLY WITH NEC SECTION 110.26. PROJECT DESCRIPTION THE PROPOSED SYSTEM IS A ROOF MOUNTED PHOTOVOLTAIC ARRAY. THE PHOTOVOLTAIC (PV) SYSTEM IS TO BE INSTALLED ON THE VLDR RESIDENTIALLY ZONED PROPERTY IN THE CITY OF CHICO, CALIFORNIA. THE ENERGY PRODUCED BY THE PV SYSTEM SHALL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ON-SITE ELECTRICAL EQUIPMENT VIA A LOAD SIDE CONNECTION BY WAY OF A 60A CIRCUIT BREAKER. THIS PROJECT DOES NOT INCLUDE STORAGE BATTERIES. URBANMDESIGN 50LAR CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. Urban'Design Solar, lm 2260`Pw k-Lenue , Chicoy CA 959.2 jS.30).;.345:'z�0065 License 4893826 B;.,C=46 PROJECT INFO ' PROJECT NO: GSD -20180222-82258 DRAWN BY: SCM DATE: 2/22/2018 zPv- 1 Y GV O W z of m Cn D W ly 07 U C/) uj o w w Y O C ILU z ' (530) 321-9269 Urban'Design Solar, lm 2260`Pw k-Lenue , Chicoy CA 959.2 jS.30).;.345:'z�0065 License 4893826 B;.,C=46 PROJECT INFO ' PROJECT NO: GSD -20180222-82258 DRAWN BY: SCM DATE: 2/22/2018 zPv- 1 N /aAPV ARRAY NEW .35-11", ' N (NON -HABITABLE STRUCTURE) , - ! 1 STRING OF 12 1 STRING OF 12 1 STRING OF 14 941-�II -_-'- ��� .� .� '� ✓ r .r �v '- �► r 714 1 , SYSTEM LAYOUT NOTES CALIFORNIA FIRE CODE NOTES CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT 1 RESISTANT PER NEC 319.0(D). CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR 2 USE IN WET LOCATIONS PER NEC 310.8(C). 1 DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN 3 METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER NEC ARTICLE 690.1(E) 4 ARRAYS SHALL BE INSTALLED IN A WAY THAT ENSURES THAT PV O LAR SOURCE CONDUCTORS SHALL NOT BE READILY ACCESSIBLE. UNDERGROUND PVC CONDUIT SHALL BE BURIED AT 19" MINIMUM' 5 DEPTH, WARNING TAPE 12". ABOVE. 6 VERIFY UNDERGROUND UTILITIES PRIOR TO EXCAVATION. 1 ..a as •' �_ ...'' �..= �. TIC PV ARRAY NEW I. B SYSTEM LAYOUT PV -2 SCALE: 1" = 20'-0 DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. CV Lu Mr � Z p ' W W frf rn 2 LN ate' >_ C/) Lu -:r- C/) cr) W LL_ U M fr_ Lu W ILLIY O Lu (530) 321-9269 CONTRACTOR OF RECORD 'Urban Design Solar,, Inc: 226,0 Pak:Ave:n'ue .,Chico, CA19S9a8 (5.30)1464006: Iicense:�893826 B;:�:C=46 Y 4 � , X SYSTEM LAYOUT PROJECT NO: GSD -20180222-82258 DRAWN BY: SCM DATE: 212212018 PV -2 CALIFORNIA FIRE CODE NOTES 1 URBANO![MDE516N IN ACCORDANCE WITH CFC 605.11.3.2.1, CFC ADDS A STATEMENT THAT 1 LADDER LOCATIONS CANNOT BE IN FRONT OF WINDOWS OR DOORS, AND CANNOT CONFLICT WITH TREE LIMBS, WIRES, OR SIGNS. O LAR THE SNAP N RACK 100 SERIES FLUSH ROOF MOUNT SYSTEM IS CLASS 2 A FIRE RATED WHEN INSTALLED WITH TYPE 1 & TYPE 2 MODULES. THE REC SOLAR REC290TP2 (BLK) MODULE IS TYPE 2. THUS, THE SYSTEM CONFORMS TO THE CLASS A FIRE RATING AS REQUIRED BY CFC. URBAN DESIGN SOLAR PHONE; 530 345-0005 LICENSE NO. 893826 B C-46 CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE 1 ..a as •' �_ ...'' �..= �. TIC PV ARRAY NEW I. B SYSTEM LAYOUT PV -2 SCALE: 1" = 20'-0 DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. CV Lu Mr � Z p ' W W frf rn 2 LN ate' >_ C/) Lu -:r- C/) cr) W LL_ U M fr_ Lu W ILLIY O Lu (530) 321-9269 CONTRACTOR OF RECORD 'Urban Design Solar,, Inc: 226,0 Pak:Ave:n'ue .,Chico, CA19S9a8 (5.30)1464006: Iicense:�893826 B;:�:C=46 Y 4 � , X SYSTEM LAYOUT PROJECT NO: GSD -20180222-82258 DRAWN BY: SCM DATE: 212212018 PV -2 PM1-38 + --� 290W, I I I I— I I I I I I 141N j ISERIES I i+ I I I DC G.E.C. 86 aARE W r - � I SOLAR MODULE Al J -BOX (EXTERIOR) Fl -6A2 15A A 11 10,000W —INVERTER (EXTERIOR) AC DISCO. (EXTERIOR) 1 I I I REF. 5 MODULE I I I I I I I I PTC POWER UTILITY I I I I I I I � I VMP FUSE RATING KWHR 1 38 I I 290W 4A C61 I 32.1V 60A I 42A I l 50OVDC � 6 r 1-- OCPD 200A MAIN (EXIS) FACTOR I I = 7 1 DERATED TO 175A (N) J AMPACITY THE OUTPUT VOLTAGE OF THE POWER OPTIMIZERS ARE REGULATED BY THE INVERTER. THEY ARE 8 NOT IMPACTED BY THE NUMBER OF MODULES IN THE STRING. THE CONTINUOUS CURRENT IS TO CUSTOMER LOADS MAIN SERVICE 2401120V 1¢, 3W (GROUNDING (EXTERIOR) 200A BUSBAR ELECTRODE, 200A MAIN BREAKER DRIVEN ROD, EXIS) TO BE DERATED TO 175A PHOTOVOLTAIC MODULE REF. TYP. MODULE STC POWER PTC POWER ISC IMP VOC VMP FUSE RATING PM1 1 38 REC SOLAR REC290TP2 (BLK) 290W 267.7W 9.71A 9.05A 38.8V 32.1V 20A INVERTER REF. TYP. INVERTER GROUND AC VOLTAGE MAX OCPD SIZE MAX OUTPUT POWER MAX AC CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY 111 1 1 SOLAR EDGE SE1000OA-US UNGROUNDED I 240VAC I 60A 10,000W I 42A I 30.5A 50OVDC 97.5% POWER OPTIMIZER SYSTEM SUMMARY ARRAY STC POWER 11,020W ARRAY PTC POWER 10,173W ARRAY CIRCUITS 1 X 14, 1 X 12,1 X 12 DC STRING OPERATING CURRENTS 11.6A, 9.94A, 9.94A DC STRING MAX CURRENTS 15A, 15A, 15A DC STRING OPERATING VOLTAGE 350V MAX AC OUTPUT CURRENT 42A CEC POWER OUTPUT 9,799W POWER OPTIMIZER REF. TYP. MODEL MAX OUTPUT CURRENT STRING VOLTAGE P01 38 SOLAREDGE P320 I 15A 350VDC OCPDS 1 REF. REF. TYP. POLES CURRENT RATING MAX. VOLTAGE F1-6 6 N/A 15A 60OVDC CB1 1 2 60A 240VAC MAIN 1 2 175A 240VAC DISCONNECTS 1 REF. TYP. I POLES CURRENT RATING MAX. VOLTAGE DS1 1 1 2 60A 240VAC GROUND FAULT PROTECTION NOTES 1 THE SOLAREDGE SYSTEM INCLUDES GROUND FAULT DETECTION AS REFERENCED BY ARTICLE 690.5 AND REQUIRED © BY 690.35 (C). BECAUSE THE ARRAY CIRCUIT CONDUCTORS ARE UNGROUNDED, ONLY THE REQUIREMENTS OF © ARTICLE 690.35 (C) (1), (2) AND (3) APPLY. EACH POWER OPTIMIZER MONITORS ITS CONNECTED MODULES AND 1 COMMUNICATES ANY DETECTED FAULT TO THE INVERTER. THE INVERTER MONITORS THE CONDUCTORS BETWEEN z W THE POWER OPTIMIZERS AND THE INVERTER. IN RESPONSE TO A GROUND FAULT THE INVERTER WILL CEASE TO 3 EXPORT POWER, SHUT DOWN THE POWER OPTIMIZERS TO ISOLATE THE FAULTED CIRCUIT, AND INDICATE THE CONT. GROUND FAULT ON THE INVERTER'S DISPLAY. SCHEMATIC NOTES 1 MAXIMUM STRING VOLTAGE OF ARRAY AT DESIGN LOW TEMPERATURE OF 4-C WOULD BE 350V. © INTEGRATED DC DISCONNECT IS PROVIDED WITH INVERTER. DISCONNECT IS LISTED FOR USE WITH SOLAR EDGE UL 1741 LISTED STRING INVERTERS. © PHOTOVOLTAIC OUTPUT STRINGS ARE COMBINED INSIDE THE INVERTERS' DC INTEGRATED DISCONNECT. ® OUTPUT OF AC DISCONNECT IS CONNECTED TO UTILITY ON LOAD SIDE OF SERVICE DISCONNECT. OUTPUT WILL BE BACKFED THROUGH A 60A CIRCUIT BREAKER IN THE MAIN SERVICE PANEL. ELECTRICAL NOTES SPECIFICATIONS INSTALLATION SHALL COMPLY WITH ALL REQUIREMENTS OF NEC 2014 AND ANY APPLICABLE LOCAL 1 AMENDMENTS. MODULE INTERCONNECTION CONNECTORS SHALL BE IN COMPLIANCE WITH NEC 690.33(.A) AND 2 SHALL BE POLARIZED AND NON INTERCHANGEABLE WITH RECEPTACLES IN OTHER ELECTRICAL SYSTEMS ON THE PREMISES. z W MODULE INTERCONNECTION CONNECTORS SHALL BE OF THE LOCKING TYPE REQUIRING A TOOL 3 FOR OPENING IN ACCORDANCE WITH NEC 690.33(C) CONT. MODULE INTERCONNECTION CONNECTORS SHALL BE MARKED "DO NOT OPEN UNDER LOAD" IN 4 ACCORDANCE WITH NEC 690.33(E). ID THE CONNECTION OF ALL MODULES SHALL BE ARRANGED SO THAT THE REMOVAL OF ANY PANEL 5 OR MODULE SHALL NOT INTERRUPT A GROUNDED CONDUCTOR TO ANOTHER PHOTOVOLTAIC CONDUIT SOURCE CIRCUIT IN ACCORDANCE WITH NEC 690.4(C). 6 ALL EQUIPMENT IN PHOTOVOLTAIC SYSTEM SHALL BE LISTED BY AN INDEPENDENT TESTING OCPD AGENCY. FACTOR THE GROUNDING ELECTRODE CONDUCTORS SHALL BE CONTINUOUS IN COMPLIANCE WITH NEC 7 250.64(C) AND 250.160. AMPACITY THE OUTPUT VOLTAGE OF THE POWER OPTIMIZERS ARE REGULATED BY THE INVERTER. THEY ARE 8 NOT IMPACTED BY THE NUMBER OF MODULES IN THE STRING. THE CONTINUOUS CURRENT IS OC CIRCUIT: SERIES STRING OUTPUT TO JUNCTION BOX CALCULATED BY DIVIDING THE MAXIMUM POWER BY THE VOLTAGE. 9 MARKING WILL BE PROVIDED IN ACCORDANCE WITH CAL -FIRE SOLAR INSTALLATION GUIDELINES. CONDUCTOR SCHEDULE WITH NEC ELECTRICAL CALCULATIONS CV 0 NO. CNDRS. RATED z W EGC TEMP. CORR. FILL ADJ. CONT. MAX. BASE DERATED ID TYP DESCRIPTION CONDUCTOR CONDUIT IN CNDT. FILL% AMPS OCPD FACTOR FACTOR CURRENT CURRENT AMPACITY AMPACITY 1 3 OC CIRCUIT: SERIES STRING OUTPUT TO JUNCTION BOX 10 AWG PV WIRE FREE AIR N/A N/A 15A N/A 6 AWG BARE 0.65 (62-C) 1.0 15A 18.75A 55A 35.75A (IN ATTIC) COPPER COPPER DC CIRCUIT (TRANSITIONED): 1012 METAL CLAD 10/2 METAL CLAD 2 3 JUNCTION BOX (IN ATTIC) COPPER FREE AIR N/A N/A 15A N/A COPPER 0.65 (62-C) 1.0 15A 18.75A 30A 19.5A TO JUNCTION BOX (EXTERIOR) DC CIRCUIT (TRANSITIONED): 8 AWG THWN•2 DIA. 10 AWG THWN-2 3 1 JUNCTION BOX (EXTERIOR) COPPER CH -4 SH -00 PVC 6 14.2 % 15A 15A IF1-6)COPPER 0.91(40-C) 0.8 15A 18.75A 55A 40.04A TO INVERTER (IN 250' TRENCH) 4 1 INVERTER OUTPUT: INVERTER TO 6 AWG THWN-2 0.75' DIA. EMT 3 32.8% 42A 60A (DSI) 8 AWG THWN-2 0.91(40-C) 1.0 42A 52.5A 75A 68.25A AC DISCONNECT COPPER COPPER AC DISCONNECT OUTPUT: AC 6 AWG THWN•2 8 AWG THWN-2 5 1 DISCONNECT TO MAIN SERVICE 0.75' DIA. EMT 3 32.8% 42A 60A (CB1) 0.91 (40-C) 1.0 42A 52.5A 75A 68.25A PANEL (POINT OF CONNECTION) COPPER COPPER ALL CONDUCTORS, OCPD SIZES AND TYPES SPECIFIED ACCORDING TO NEC ARTICLES 690.8(A)(1), NEC ARTICLE 240, AND NEC ARTICLE 690.7. IIRBAIIII] DE616N SOLAR PHONE: 530 345-0005 LICENSE NO. 893826 B C46 CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. Urban Design Solar, Inc. 22-60 Paik Avenu6 Chico; CA 93928' (30) .345-0005 lAcense #893826 B, C,46 SINGLE -LINE DIAGRAMI DRAWN BY: SCM PV -3. CV 0 Lu z W O cr_ CJ of W � Q Cn Cm LU LL - U O w � U of C7 Lu (530) 321-9269 Urban Design Solar, Inc. 22-60 Paik Avenu6 Chico; CA 93928' (30) .345-0005 lAcense #893826 B, C,46 SINGLE -LINE DIAGRAMI DRAWN BY: SCM PV -3. JUNCTION'BOX I O JUNCTION BOX ® WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED NEC 690.35(F) 3Q JUNCTION BOX & WARNING PHOTOVOLTAIC POWER SOURCE NEC 690.35 INVERTER ® INTEGRATED DC DISCONNECT (INVERTER 11) PHOTOVOLTAIC SYSTEM DC DISCONNECT OPERATING VOLTAGE 350 VDC OPERATING CURRENT 31.49A MAX SYSTEM VOLTAGE 500 VDC SHORT CIRCUIT CURRENT 45A NEC 690.53 © INVERTER (11) ® WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED NEC 690.35(F) ® INVERTER(11) SOLAR INVERTER MAXIMUM RATING OPERATING CURRENT 42AMPS OPERATING VOLTAGE 240 VAC Q JUNCTION BOX DO NOT © DISCONNECT UNDERLOAD NEC 690.16(B) 5Q INTEGRATED DC DISCONNECT (INVERTER 11) SOLAR DC DISCONNECT NEC 690.13(8) �;, ® WARNING ELECTRIC SHOCK HAZARD IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED NEC 690.5(C) 9Q INVERTER (11) PHOTOVOLTAIC SYSTEM EQIUPPED WITH RAPID SHUTDOWN NEC 690.54 NEC 690.56(C) RACEWAYS & OTHER 10 RACEWAYS, CABLES PER 10 FT. 11 PV WIRE CONNECTORS DO NOT ® WARNING ® © DISCONNECT PHOTOVOLTAIC UNDER LOAD POWER SOURCE NEC 690.16(B) NEC 690.35(F) MAIN -SERVICE PANEL l� uuu nrm nnr neon ® WARNING DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM NEC 690.56(B) 14 MAIN SERVICE PANEL ® WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE NEC 705.12(D)(7) 16 MAIN SERVICE PANEL ® WARNING SOLAR ELECTRIC BREAKER IS BACKFED AC DISCONNECT 18 AC DISCONNECT (RSI) PHOTOVOLTAIC SYSTEM AC DISCONNECT OPERATING CURRENT 42AMPS OPERATING VOLTAGE 240VOLTS 13 MAIN SERVICE PANEL ® WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.17.4 15 PV SYSTEM DISCONNECT (CBI) PHOTOVOLTAIC SYSTEM AC DISCONNECT OPERATING CURRENT 42AMPS OPERATING VOLTAGE 240VOLTS NEC 690.14(C)(2) & NEC 690.54 17 MAIN SERVICE PANEL ALL PLACARDS AND SIGNAGE REQUIRED BY THE 2016 CEC, 2014 NEC, AND ANY OTHER STATE CODES OR LOCAL ORDINANCES WILL BE INSTALLED AS REQUIRED. MAIN BREAKER HAS BEEN 20 MAIN SERVICE PANEL RESIZED TO 175AMPS O CAUTION © DO NOT UPSIZE BREAKER REQUIRED BY AHJ 19 AC DISCONNECT (DS1) ® WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.1.7.4 1 PLACARDS PV -5 SCALE: NTS PLACARDS DRAWN BY: SCM DATE: 2/22/2018 PV=4 MAIN SERVICE PANEL 1 ALL PLACARDS AND SIGNAGE REQUIRED BY THE 2016 CEC, 2014 NEC, AND ANY OTHER STATE CODES OR LOCAL ORDINANCES WILL BE INSTALLED AS REQUIRED. URBAN�1 DE516N 20 MAIN SERVICE PANEL "SOLAR O CAUTION © 4 MINIMUM 3/8" LETTER HEIGHT 5 URBAN DESIGN SOLAR PHONE: 530 345-0005 POWER TO THIS SERVICE IS ALSO SUPPLIED FROM LICENSE N0.893826 B C-46 THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART N TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. CV . o INVERTER W p (EXTERIOR cn Z O ti AC DISCO. 0,3 W o(EXTERIOR N W200A SERV � LU W(EXTERIORLLI NEC 690.56(8) cif W O Q J CSO = V z (530) 321-9269 CONTRACTOR OF RECORD • Urban Design Solar�;In�: _IZ69 :C�iicoy :CA �95925 .,030).345_=0005 I icense;#893826 B;;C' 46 1 PLACARDS PV -5 SCALE: NTS PLACARDS DRAWN BY: SCM DATE: 2/22/2018 PV=4 SIGNAGE REQUIREMENTS 1 ALL PLACARDS AND SIGNAGE REQUIRED BY THE 2016 CEC, 2014 NEC, AND ANY OTHER STATE CODES OR LOCAL ORDINANCES WILL BE INSTALLED AS REQUIRED. 2 RED BACKGROUND -3 WHITE LETTERING 4 MINIMUM 3/8" LETTER HEIGHT 5 ALL CAPITAL LETTERS 6 AERIAL OR SIMILAR FONT 7 WEATHER RESISTANT MATERIAL, PER UL 969 1 PLACARDS PV -5 SCALE: NTS PLACARDS DRAWN BY: SCM DATE: 2/22/2018 PV=4 METAL L -FOOT PV MODULE RACKING RAIL PURLIN LL a RIDGE 60" ----------------------------------- - ----------------------------------- -------- NUMBER OF MODULES 38 NUMBER OF MID -CLAMPS 64 NUMBER OF END -CLAMPS 24 NUMBER OF ATTACHMENTS 64 AREA 683 SQ. FT AZIMUTH 162° (:D CLu /:)�wU L Y D w J OU co _ G� Lu (530) - - ---- - ------- ------- - - ------- ------- - - ------- ------- - - ------- ------ - - ------- ------ - 60" 60.. 60" ROOF INFORMATION ROOF TYPE METAL ROOF BASE PITCH 10° PURLIN SPACING 60" O.C. LAYOUT SPECIFICATIONS NUMBER OF MODULES 38 NUMBER OF MID -CLAMPS 64 NUMBER OF END -CLAMPS 24 NUMBER OF ATTACHMENTS 64 AREA 683 SQ. FT AZIMUTH 162° tAVt 33'-2" STRUCTURAL CALCULATIONS WIND EXPOSURE CATEGORY B DESIGN WIND SPEED 120 MPH (3 -SECOND GUST) ROOF DESIGN SNOW LOAD 0 PSF (VALLEY FLOOR) TOTAL WEIGHT OF ARRAY 1932 LBS POINT LOAD 30.2 LBS DEAD LOAD 2.83 PSF __F I 60" O.C. Lu 19'-101 ATTACHMENT NOTES 1 ROOF MEMBERS AND PENETRATIONS TO BE DETERMINED IN THE FIELD. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR 2 BUILDING ROOF VENTS. 3 FLASHING SHALL BE APPLIED IN ACCORDANCE WITH MANUFACTURERS' PRINTED INSTRUCTIONS. wo W IF THERE IS ANY CONFLICT BETWEEN WHAT IS DEPICTED HERE AND INSTRUCTIONS PROVIDED BY THE 4 MANUFACTURER, MANUFACTURERS' INSTRUCTIONS SHALL SUPERCEDE. 1 ATTACHMENT PLAN JP -5 SCALE: 1" = 5' URBMCC DE5161N 50L.AR CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. trban'Des_ign Solar; -Inc 2260 Park Aveil-ue :Cluco�:CA 95928 000�- .lAcense ,4893826 B, ,C==16 wc-G%_�C_�:y ATTACHMENT PLAN DRAWN BY: SCM PV -5 Y CV 0 wo W Lo Fw- U (:D CLu /:)�wU L Y D w J OU co _ G� Lu (530) 321-9269 trban'Des_ign Solar; -Inc 2260 Park Aveil-ue :Cluco�:CA 95928 000�- .lAcense ,4893826 B, ,C==16 wc-G%_�C_�:y ATTACHMENT PLAN DRAWN BY: SCM PV -5 ,. v STEP 1: " , : �' + . : " c•.I x� F c.,s,!a�ft=: REVISION: ATTACH METAL ROOF BASE TO, P4IRLIN• WITH �.. "@ . , ' ' �'` :5100 PEN -D12 , F. 1113D/2013 DR TEK OR•EQUIVALENT SELF DRILLING SCREW:-, , , - - PROJECT NO: GSD -20180222-82258 TORQl1,E:TO MANUFACTURER SPECIFICATIONS: t Oii(4 i�j Tl�ll ia�{ — ';APPROVED BY iG:Md6e4ers 11/28/2017.. STEP i J THREAD METAL ROOF BASE CAP. ONTO METAL '- ' ' • - - - . ROOF. BASE BOTTOM TAKE CARE TO ENSURE -THE' BASE DOES' NOT TWIST. WHEN. CA P. LS TIGHTENED:. �' • `• ` �' ENSURE CAP-IS'FULLY: SEATED TO BASE: - 1 '• .r DRAWN BY: SCM STEP 3: •. ` : _ - .., - .. .. , r DATE: 2/22/2018 , ATTACH' STANDOFF .TO STUD IN METAL' ROOF " . } - . BASE CAP.• ,.SNAPNRACK, f {cn • L1.1 •, STANDARD',RAIL ATTACHMENT DATASHEET SCALE: NTS :SN'APNRACK CHANNEL NUT �•AL 0-18 X 1„UPPER SEALING WASHER. ti ' ,R•ANGE BOLT SEALS'CAP OF METAL ROOF. • BASE• Lu (530)321 -9269 ROOF, • ,� , ` PANEL, TYP: `SNAPNRACK METAL - +, m ROOF BASE•CAP _ UPPER', GASKET' ”. SEALING }WASHER. SEALS METAL ROOF BASE STEEL PURLIN', T ';ROOF SURFACE F FLANGE;•:TYP. SNAPIVRACK' ALUTURPOSE ' • y ` .900 .. ; : a"0 TEK; OR EQUIVALENT SELF ATTACHMENTsFASTENER %s"0 1® 5.5. - . DRILLING FASTENE R, WITH %"� �. , 1 �»n VJ TEK SCREW. TYP. FLANGE NUT MAX Q,.W.WASHER , t , INTOROOF:PURLINS METAL ROOF PANEL; TYP, -. ,- + - MIN: 3a,THREADS PROJECTING ' THROUGH 'STEEL" Pt1RLIN - ••STEELPURLIN; TYP: r' .. r L_OWER'GASKET SNAPNRACK METAL ` • ROOF'BASE BOTTOM: Sunrun South LLCDESIGNER G`. MCPhe@tOfS; SCALE: • ; SMS J ,PART NUMBER: DESCRIPTION:. REV ,2. UR0MCC nEsmsr4 50L.AR CONTRACTOR OF RECORD Urban -Design Solar;�iilc. PirkAVeLe Chico, GA 95928' „(130}•3�5=00b5 License #893826 B; �G46 ATTCH. DATASHEET 11-�� CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. c•.I x� F c.,s,!a�ft=: ';DRAFTER: D:Ryan OATE:, :5100 PEN -D12 , METAL ROOF BASE TO PURLIN ;V , , - - PROJECT NO: GSD -20180222-82258 �. t Oii(4 i�j Tl�ll ia�{ C4 ';APPROVED BY iG:Md6e4ers 11/28/2017.. Lu c. J c Q ti - - - - M"T0fW6E"f GF69 illUa.O(lf, 116. •'i•C 'Q rn w DRAWN BY: SCM ..... _ DATE: 2/22/2018 cn 'Lu U_ U wO {cn • L1.1 •, ATTACHMENT DATASHEET u.1 `� U SCALE: NTS Lu (530)321 -9269 CONTRACTOR OF RECORD Urban -Design Solar;�iilc. PirkAVeLe Chico, GA 95928' „(130}•3�5=00b5 License #893826 B; �G46 ATTCH. DATASHEET 11-�� c•.I x� F c.,s,!a�ft=: ';DRAFTER: D:Ryan OATE:, :5100 PEN -D12 , METAL ROOF BASE TO PURLIN ;V , , - - PROJECT NO: GSD -20180222-82258 t Oii(4 i�j Tl�ll ia�{ r.wrc�w�nHranavwr'msoemucveagecmFrun exv aecroacrm.ruaasr�e.onussr_;er�or'bwc'='mr l0,7TA. ';APPROVED BY iG:Md6e4ers 11/28/2017.. yw J - - - - M"T0fW6E"f GF69 illUa.O(lf, 116. •'i•C DRAWN BY: SCM ..... _ DATE: 2/22/2018 ATTACHMENT DATASHEET SCALE: NTS URBANU DESIGN SnapNrack y r -URBAN DESIGN SOLAR Solar Mounting SolutionsPHONE: 530 345-0005 SnapN rc�ckn LICENSE N0.893826 B C-46 Solar Mounting Solutions CONFIDENTIAL: THE INFORMATION CONTAINED Series 100 Rasidantial Roof Mniint Systiam INTHISDRAWINGSETISCONFIDENTIALAND The SnapNrack Series 100 Roof Mount System is engineered to optimize materiai•use, f labor resources and aesthetic appeal. This innovative system simplifies the process of installing solar modules, shortens installation times, and lowers installation costs; ` maximizing productivity and profits: ; The Series 100 Roof Mount System.boasts unique, pre -assembled, stainless steel "Snap in" hardware and watertight flash attachments. This system is installed with a single tool. No cutting or drilling means less rail waste. It is fully integrated with built-in wire , management, solutions for all roof types, one -size -fits -all features, and can withstand. ' extreme environmental conditions. 'Series 100 is listed to UL Standard 2703 for .s r Grounding/Bonding, Fire Classification and Mechanical Loading. UL 2703 Certification and Compliance ensures that SnapNrack installers can continue to provide the best in - - class installations in quality, safety and efficiency. O Appealing design with builtAn aesthetics O No grounding lugs required for modules O All bonding hardware is fully integrated O Rail splices bond rails together, no rail jumpers required O No drilling of rail or reaching for other tools required O Class A Fire Rating for Type 1 and 2 modules SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. C%4 _ o - U Q ti W W � � C~/) C) C)f C3� C/3 w � U M W U-1 Cif Y O U-1 � J C.0LLI U z (530)321-9269 CONTRACTOR OF RECORD Urbanbesign Solar,,'InC. 226t? Fukveaiue (Chico, CA.9 928 ,030.).345-0006 • 6000 Series aluminum IlAkense #8938_26 8,_,,C=46 Materials • Stainless steel • Galvanized steel and aluminum flashing System Features Include _ • Silver and black anodized aluminum Material Finish •Mill finish on select products �/ fRiT�^7tt�1""'- • Silver or black coated hardware � , Q Note: Appearance of mill finish products may vary and change over time. , Snap in 'Single Tool Easy No Cutting Wind Loads 110 -190 mph (ASCE 7-10) Hardware '^ ' ... Installation Leveling or Drilling _71 RACKING DATASHEET ' r Snow Loads , 0 - 120 psf Array Pitch 0 - 60 degrees - integrated Wire Preassembled - d e PROJECT NO: GSD -20180222-82258 Integrated bonding UL 2703 Certified - ' Management hardware DRAWN BY:L SCM Resources snapnrack.com/resources 1 Design snapnrack.com/configurator I , Where to Buy snapnrack.com/where-to-buy' 877-732-2860 - 1 WWW.snapnrack.COm 1 contact@snapniack.com DATE: 2122/2018 © 2016 by SnapNrack Solar Mounting Solutions. All rights reserved suaraaksion�oa.•ezi - . - :* � � `' E: , • : •� ; . '� � RACKING DATASHEET - . PV _ 7 • �. PV -7 SCALE: NTS 1 SOLAR K ; URBAN DESIGN SOLAR ` PHONE: 530 345-0005 - ' LICENSE NO. 893826 R C-46 REC T.WINPEAK 2 SERIES CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART Ialsa Ia w.11 _ - 1 1311.11 91013591 331515.051 . :'coos, + -- • ..t4eaarwrmtiFmmpj El 1110.2 10.43 x091 Product Code*: RECxxxTP2 280 21.85. 290 2..95 ' . � r '- Watt ClassSorting-(W) 0/ 5 SE - (O.M.0431 „1IW 1171 a - 1 :111.51 • ..t4eaarwrmtiFmmpj ELECTRICAL DATA @ STC- ^'Nominal Power-P-(Wp) 275 Product Code*: RECxxxTP2 280 21.85. 290 2..95 ' . � r '- Watt ClassSorting-(W) 0/ 5 ' _ 0/+5 0/5 0/+5 0/+5 NominalPowerVolta a -V 31.5 g nwoN) 31.7 319 32.1 '' 32.3 Nomina,Power Current- I,(A) 8.74 : 8.84 8.95 9.05 9.14 . Open Circuit Voltage-Va(V) 38.2 38.4 38.6 38.8 39.0 Short GrcuitCurrent -1v(A)�d 9.30 9.39 9.49 9.58 - 9.65 y Panel Efficiency(%) 16.5 16.8 17.1 17.4 17.7 -* Vahlesa[standard testc"nouinisSTC(airtnassAMlS.Irradmlce l000W/m'.ceU terrperatwe 25'C). DRAWN BY: SCM + ' Atl..dia.eof2WW/m'(AMISmdce0temperatwe25Y)atleast94%oftheSTCmoduleefficimcywiUbeadve cL 3 • e *Where- indicates the nominalpowerdass(P,,, Jat STC indcatedabomandanbe followed" suffix BLKforbladef arned modules DATE: 2/22/2018 ,� i ,� + .y ,' i, ELECTRICAL DATA • ' Nominal Power-P.(Wp) 206 210 214 218 223 + NominalPowerVoltage-V,�(V) r 29:2 - W 29.4 29.6 29.8 30.0 Nominal Power Current-I_(A) 7.07 7.15 7.24 7.32 7.43 OpenC•trcuitVoltage- Va(V) 35.4 35.6 36.0 36.2 �ShortCircuitC'urrent-Iu(A) - 7.52 y _35_.8 7.59 =:-� 7.68 X7.75 7.85 Nominaloperatingcelltempeatwe NOCT(80OW/m',AM15•wlndspeedlm/samblwttempeature2M • - .. +-Wheresabdlutesthenomlmipo class(P„+JatSTCUldlatedabo andmbefallonedbythesuffu BLKfwbtackh mdmodules. CERTIFICATIONS 10 year product warranty - `" DVE r Cr/ Ac 25year' inearpower output warranty 0�us (ma:.degressloo in performance ofO.7%p.a. from 97% ' UL1703•FoedassifiationType21EC61215.IC{6173(X i afterthe firstyear), "'IEC 617M (Salt Mist --erityle'el 61 IEC 62804(PID Free). '• ...:IEC See warranty conditions for further details. ' 62716Wnmonla Resistancel ISO 11925-21[Wutability Class lL- + ,�UNIS457/9174(Cb3ss AL1509001:2015,15014001.OH5ASISMI ;i, '• - i TO ANYONE EXCEPT THOSE INVOLVED IN THE • DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. CN . Y - U In Cr)W LU - t n U) I W U Uj LLJ s � WC) ' Y U J Co = �LU r U ` z . • (530) 321-9269 CONTRACTOR OF RECORD _' L7rban�Design Solar;$Inc: :Cluco :CA:9S928' {30 ,345000 w License =893826 B;: C=46 • . _ .. 5�-�-� r Y ' GGA--c�c.� _ Founded in Norway in 1996; RECisaleadingverticallymtegratedsolarenergycompany.Throughintegratedmanufacturingfromsilicon 's RE to wafers, cells, high-quality panels and extending to solar solutions, REC provides the world with a reliable source of clean energy. RECs RCS 4 ®` renowned 00N0O%� renowned product quality is supported by the lowest warranty claims rate in the industry. REC is a Bluestar Elkem company with in Norway and ope ra tional headquarters in Singapore. REC employs more than 2.000 people worldwide. producing 1.4 GW MODULE DATASHEET of solar panels annually. . wwwrecgroup.com 100% REDUCES BALANCE OF )ID FREE SYSTEM COSTS -'t` Z' .• • - ' `- " ; - - • >r. ,'` , + "' • •' L ;`; r PROJECT N0: GSD -20180222-82258 r t + 'f fi . DRAWN BY: SCM + 3 • e DATE: 2/22/2018 ,� i ,� + .y ,' i, �, , 1. MODULE DATASHEET .. : 4 . i} ` a • , PV=8 'h.- �. i 9 PV -8 SCALE: NTS_ a i _ ... - . .. -. ..i: - Yom•.,,,.. i.�. t �. •. �, - t': ^.s / r �.. L ... - • - .. solar- .. � -• � r ' SolarEdge Single Phase Inverters For North America _ SE3000A-US / SE380OA-US / SE5000A7US / SE6000A-US / SE7600A-US SE10000A-US / SE1140OA-US 'The best choice for SolarEdge enabled systems Integrated arc fault protection for NEC 2011690.11 compliance Rapid shutdown for NEC 2014 690.12 — Superior a ciency 98 4 Small, lightweight and easy to install on provided bracket Built-in module -level monitoring Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter, DC/AC conversion only Pre -assembled Safety Switch for faster installation Optional — revenue grade data, ANSI C12.1 I USA -GERMANY -ITALY-FRANCE -JAPAN - CHINA- AUSTRALIA -THE NETHERLANDS -UK -ISRAEL ` 4 ' wwwsolared a us b "'• NVERTER DATASHEET sunsl>Ec R �• - � � • r. ' ' ` ' PROJECT NO: GSD -20180222-82258 ' DRAWN BY: SCM DATE: 2/22/2018 INVERTER DATASHEET p\/ q • PV -9 SCALE: NTS. 1 Y V URBANUf DESIGN + Single Phase Invel'tePS for North America •solar• • URBAN DESIGN SOLAR SE300oA-US / SE360oA-US / SE500oA-US / SE600DA-US / PHONE: 530 345-0005 SE7600A-US / SE10000A-US / SE11400A-US LICENSE NO. 893826 B C46 SE3000A-US SE390OA-US sE5000A-Us I SE6000A-US I SE760OA-U SE10000A-US SE1140OA-US CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR N PART I OUTPUT I Nominal AC Power Output 9980 @ 208V 3000 3800 S000 6000 7600 11400 10000 @240V, '" "' VA """"" ' ' "" """' " x. AC """ 300 """5' " 5400 @ 208v ' '" 8350 -ioaoo @ 208V 00 TO ANYONE EXCEPT THOSE INVOLVED IN THE Max. AC Power Output Po .........................................I............... 3300 000 4150 6000 8350 .............. I, Baso@zaov............................... I, 12.. . io9so,@zaoy.................. I.......... VA DESIGN AND INSTALLATION OF THE PV SYSTEM AC output Voltage Min -N om: Max.10 J J REPRESENTED IN THIS PLAN. 3 - 208 - 229 Vac 83-u ...........................I...............I. :... ................ ..:....... AC Output Voltage Min: Nom: Max.l'1 J - 211- AC frequency Min.:Nam:.Maz ii1.......� ................. .59.3: 60: 60.5 ................. .........'........ I :. Hz ... Max. Continuous Output Current Output Current .......I ............... 12.5 .....................1.......I..21,@z4ov................................I...9?.P.zaoY..:I:.......................... ........... ............. 24 @ 208V 16 25 32 48 @ 208V 47.. A A N r........... ....... GFDIThreshold. 1 1 ............... ............... ................. A �.•-.•.,,-.• O ....................... Utility Monitoring Islanding Protection, .............. ............................... Country Configurable Thresholds Yes 1 Yes' cc W s.�IINPUT Maximum DC Power(STC) - ............................ 4050 5100 6750 8100 10250 13500 15350 ..... ................... ................. ................ W .. .. ' Transformer -less, Un rounded Tran form ...�..... �............................................ Yes .................................................... �.......... W z 0 Qi .-less Max:lnput Voltage......... � .. .....I...Vdc w LO Nom. DC Input Voltage .... .. . ............... .. .......500.... ............... 325 @ 208V / 350 @ 240V ..1.......@....... ................ 1 Vdc 07 0 :....... Max. Input CurrenN21 n t Cur 9.5 16.5 @ 208V 13 18 23 I I................. 33 @ 208V 34.5 I.................1.......... Adc w Q ............................... .... ....... ....:... .... 15.5 240V ............... ...................... 30.5, 240V @........ LU Li—U Max. Input Short Circuit Current 1 45I Adc Q 0f LU Reverse:Polariry Protection............I ............... ............................... ........Yes.... ............... ................. ................. I.......... L u W Ground-Faultlsolation Detection. ( 600kaSensitivity . ..- Y U Maximum inverter Efficiency..........1.....97.7..... ........................ ........ I.....98.2......I..... 98.3...... 1.....98:3..... 1......98...... I....... 98.. `.... 1.......98....... I....% . . W CEC Weighted Efficiency '1..••97:5....1....'98.•..•.'• 97 @ 208V 97.5 97.5 97 @ 208V 1 97.5 .97: 5. a�1, 240V ................ 1 %......... 0 J ti � U ................................... Nighttime Power Consumption < 2.5 <4 1 W V _ I ADDITIONAL FEATURES _ Supported Communication Interfaces RS485, RS232, Ethernet, 2igBee (optional) ..................................................... .......................... .... ........... .. .... ....... _ Revenue Grade Data ANSI C12.1- •- 0 tiona1N1- ..................................................... Rapid Shutdown - NEC 2014 690.12 ............................... ......... ... ............... Yes ......... , Lu z - (530)321-9269 • I Safety ................................................ UL1741, UL1699B, UL1998, CSA 22.2 ............ ............... . .......... Grid Connection Standards 1 ..............................I ............... ........................... IEEE1547 ............ ................. ................. 1 .......... ` CONTRACTOR OF RECORD Emissions FCC part15 class B I I INSTALLATION SPECIFICATIONS ) ' �� i ;t� Lirban De $IQ S1at1 1110 - AC output conduit size JAW range 3/4" minimum / 16-6 AWG 3/4" minimum / 8-3 AWG ..................................... .. ............... ............... ................. ................. ......... DC input conduit size / ft of strings / AWG rang? 3/4 minimum / 1 2 strings / 16-6 AWG 3/4" minimum / 1.3 strings / 14;6 AWG............ I. •�rrte/, , _ � � / AA q-GlS1I Fmk .............................1............... ........................ .... ............... ............... ............ ... 11v�u� _ Dimensions with Safety Switch :-(HxWxD)••.. I• 30.Sx12.5x7.2/775x315x184 ... I,.-,•,....775x315x260 30.5 x 12.5 x 10.5 / m / mm .. ., . ;. ';Cf icol,'CA 95028' Weight with Safety Switch .............1..........51.2/23.2 ......... ................ .54:7./ 24:x.. ............... I Natural ........... 88.4/40.1 ............ I ..I. /.kg.. t�30,- 345-0U�5 r 'Cooling convection Natural Convection and internal Fans (user replaceable) " , License ; 893826 B, C-46 fan (user.............. .... replaceable). ... ............ ... ................ Noise ............................................ Min. Max. Operating Temperature :......:... 25 I < 50 1 dBA GG -13 to +140 / -25 to +60 (-40 to +60 version available (4)) ( 'F /'C t ��� ...............................................:. .......: ' ..................... ............... ............... ..............::. ................. _ , -Protection Rating......................1. ...NEMA 3R. ............... ... .................1..........." ui For other regional settings please contact SolarEdge support. U1 A higher current source may be used; the Inverter will limit Its Input current to the values stated. - - ' 'ts� Revenue grade Inverter P/N: SExxo A-US000NNR2 (for 7600W Inverter.SE7600A-US002NN112). ' [41-40 version P/N: SEnonA-US000NNU4(for 760OW lnverterSE7600A-US00214111.14). b "'• NVERTER DATASHEET sunsl>Ec R �• - � � • r. ' ' ` ' PROJECT NO: GSD -20180222-82258 ' DRAWN BY: SCM DATE: 2/22/2018 INVERTER DATASHEET p\/ q • PV -9 SCALE: NTS. 1 Y V solar- p Xo& SolarEdge Power Optimizer - Module Add -On For North America P320 P370 / P400 / P405 / P505 PV power optimization at the module -level — Specifically designed to work with SolarEdge inverters - - Up to 25% more energy Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module -level monitoring Compliant with arc fault protection and rapid shutdown NEC requirements (when installed as part of the SolarEdge system) — Module -level voltage shutdown for installer and firefighter safety USA -CANADA -GERMANY -ITALY - FRANCE-IAPAN- CHINA•AUSTRALIA -THE NETHERLANDS -UK -ISRAEL -TURKEY -SOUTH AFRICA• BULGARIA -INDIA www.solaredge.us r. ' URBANM1 DESIGN 50LAR SolarEdge Power Optimizer DESIGN PHONE 530 345-0005R so a r p 0 �` - Module Add -On for North America LICENSE NO. 893826 B C-46 CONFIDENTIAL: THE INFORMATION CONTAINED P320 / P370 / P400 / P405 / P505 IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART - r P320 P370 P400 P405 P505 OPTIMIZER MODEL (for high-power (for higher -power (for 72 & 96 cell (for thin film (tor higher TO ANYONE EXCEPT THOSE INVOLVED IN THE (typical module compatibility) 60 -cell modules) 6o and cell modules) modules) current modules) DESIGN AND INSTALLATION OF THE PV SYSTEM modulles) REPRESENTED IN THIS PLAN. ` f INPUT - ) RatedlnputDC Pawer'i 320 370 400 - 405 •.. 505 W Absolute Maximum Input Voltage -••..---••--- 48 60 80 125 .. MPPT Operating Range ......... �....... 8:.60....... �....... 8:.80.......1...........12.5: 83...... 1.... Vdc..... £ Maximum Short Circuit Current (Ise►...... ......8:.48....... ....................11.................... �..:................ 10:1:.-................ �......-..14...:..... I.... Adc..... �C CN ' Maximum DCinput Current ......•....I 13.75 12.63 •..1....,...17:5.,,..,-.1....Adc ...................99.5 ....... ................:. Maximum Efficiency I 99.5 I % ' ' Wei hted Efficient �.............. y..........::........... 98.8 l .................. 98.6 I..................... % I ............ �— LU Overvoltage Category ` _ • I - - II - + CC •C Uj n - U Q ti Qi w Lf) ` t OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) ( - �.� Maximum Output Current 15 Adc ... ... .. ..... . Maximum Output Voltage 60 I 85 I... Vdc � ' ` 1 OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) (%� w w LU Safety Output Voltage per Power 1 t 0.1 Vdc - Optimizer ' 0 w V w Y Q ' 1 STANDARD COMPLIANCE1 EMC FCC PartlS Class B, IEC63000-6-2, IEC61000-6-3 .................... ..................... ..................... ..................... ..................... ............. SafetY.....................................�..................... ..............IE .... ..:1(classIIsafety)(UL1741.............. .....-...............I............. _ �— w U ` RoH5 1 Yes - IINSTALLATION SPECIFICATIONS Maximum Allowed System Voltage - 1000 Vdc ... ..................... ..................... ..................... Compatibleinverters , .... rn.paii.bI.e I All SolarEdge Single Phase and Three Phase inverters .,..,,.,...,.,,,..... - Dimensions (W x L x H) 128.152x36/ 128.152x50/ 128x152x28/5xS.97x1.1 5.5.97x1... .... x1.96 128x152x59/ mm/in I Sx5:97x23....I........ ' Weight (including cables).:-.............. 1 /.1:4................. 750 / 1:7..... 845 / 1:9 1.....1064 / 2.3..... I... gr./ lb.... � LU Input Connector ......................................................................................................................................... .................630_ - I MC4lt) ...... .............I----•-..--.-- . z :•(530) 321-9269 Output Wire Type /Connector' I Double Insulated; MC4 1 ., Output Wire Length �.... 0.95 / 3:�..... �...........:.... 1.2 / 3:9................. n................1... T.0.... CONTRACTOR OF RECORD ...................... -- Operating Temperature Rang? ' I ..................... ....................: 40.:+85 / ...... 185.................... ... . I e /'l ........ ....... •„ ProtectionRatin �' IP68/NEMA6P 1 - ..................... ..................... ..................... ..................... ............. g ............................................... Relative Humidity ................................................................ In Rated STC Module I 0 -100 ..................... ..................... ..................... 1 % ..................... ............. . Urban Design Solan'4 tic. power of the module. of up to +5% power tolerance allowed. ' - `jj""]]��^pp((�� '+ pl For other connector types please contact SolarEdge t� ��rr�G4t71..� f"fpp-`�•' - �. iChiCoy-CA.9592S PV SYSTEM DESIGN USING SINGLE PHASE - 1 --: A SOLAREDGE INVERTER0101 HD -WAVE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V- - Minimum String Length .P320,,P370fP400 (Power Optimizers) P405 / P505 .......................... ........ ...........................8......................... ,,,-,•.,,,10,•.,•..,.„ .•,.,,,.„18,-,-,.•„•. 6 ........................1 ...........8............ .........:.14........... ......................... . ............ i License B lC erase X893826 ,- Maximum String Length 25 I 25 50sl _ 146 .. • :, r (Power Optimizers) .......................... Maximum Power per String 5700 (6000 with 5250 6000 SE7600H:U51.....\ ....................... 12750 W Parallel Strings of DlfferentLengths,. ! _,� ' _ tions or Orient _ ................................. - Yes ................................................................................................................. ' 111 For detailed suing slang Information refer to: httpl/www.wiaredge.mm/sites/def.ulVRlWstring_sizing_w.pdf. 141 it Is not allowed to mix P405/P505 with P3Z0/P370/P400/P600/P700/P800 in one string. - - pi A string with more than 30 opdmizers does not meet NEC rapid shutdown requirements; safety Voltage will be above the 30V requirement ` C E E1b So4nEdgc feehnologleswl�ne. A!1 nghls le5r.:rved^SOI,.RLUGt. the SelaFdgeIoglu. OPTIti11ZEU_BY SOLAREDGE rale Vatic SFS of agislered ;roderLs o 5olarEtltir:�cihnobglG In All other de-� Fav n7a-=17. hU cin re vddclnarks of their reSpicu�C o'nnur Uole. OJ.%?0 t8iVq 1?ft:G !A\1. Scbieu tp cn0nge :(.;hot t Iwuc^. OPTMZR.DATASHEET PROJECT NO: GSD -20180222-82258 ' DRAWN BY: SCM • DATE: 2/22/2018 POWER OPTIMIZER DATASHEET ' • - r . i .V-10 SCALE: NTS -PV-10 W_ URBANDESIGN SnapNrack- k.com SOLAR solar mounting solutions J URBAN DESIGN SOLAR PHONE: 530 345-0005 LICENSE NO. 89382613C46) 7 {- SnapNrack UL 2703 Fire Classification CONFIDENTIAL: THE INFORMATION CONTAINED February 2015 IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE • DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. As of January 1st, 2015 many jurisdictions are now enforcing codes based.upon updates to the International Building Code (IBC) and UL Standards 1703 (modules) and 2703 (mount- ing systems). The language included in the 2012 IBC requires that the combination of. roof mounted solar modules and racking components -is to be considered a system (IBC Section CV 1509.7.2). Additionally, it requires that this system shall meet or exceed the fire classifica- o. tion of the roof assembly: _ U Q M O r The objective is to ensure that the LU LU 0D PV system does not adversely affect C/) 0_ rn the fire rating of the roof. Roof sur- t/) LU Q U face fire ratings are classified either LU W A, B, or C; Class A being the most LU LU O resistant to the spread of flame. LU ti U 0 Since the physical characteristics of the PV module (material, thickness of glass, etc) also potentially af- fect how a fire will act, modules are. 1 "type" LTJ (530) 321-9269 now tested and assigned a based upon these characteristics and CONTRACTOR OF RECORD spread of flame test results. There are 15 total module types, Types 1, 2 and 3 represent dif- ferences in the module composition and Types 4 - 15 are the same module compositions as ' CiPban Design Solara Iris: . Types 1 - 3 with differing fire test performance. X260 Fatk Avenue SnapNrack Series 100 has been Certified for a Class A fire rating with Type 1 and Type 2 .`5928 Chieoa:CA.9 modules, in accordance with the standards set forth in UL1703/2703 and IBC 2012. In or- (30,345=0005. der to maintain this classification, the SnapNrack mounting system must be installed per License #893826 B; iG46 the UL -approved Installation Manual.. Because the test was conducted with the modules at 5 inches from the roof surface (worst case scenario), there is no restriction to the standoff height. Attachment 1 is the SnapNrack AIMS File which is accessed through the UL Online Certifica- tion Directory, .or available here: SnapNrack GUMS File. - , The full SnapNrack Series 100 UL Test Report is available by sending requests to C�ASS A FRE RATING. appeng(cbsnapnrack.com. PROJECT NO: GSD -20180222-82258 DRAWN BY: SCM DATE: 2/22/2018 Resources snapnrack.com/resources Design snapnrack.com Where /configurator to Buy snapnrack.com/where-to-buy 877-732-2860. I. www.snapnrack.com I. contact@snapnrack.com 1 CLASS A FIRE RATING DATASHEET -. V-11 SCALE: NTS.PV_-1 .1 January 4; 2018: SnapNrack 'Norma -a 775 Fiero Lane; &e. 200 San LUIS ObISpq;_'CA 93401', Attu.: SnapNrack: Engineering Departhienu S-heei c lke:Rert i.��(�A.65.�'Sn;jpNtack-Seties,100.Soiar P.. dtoyo,li po tPic.,Racking .System with §,063-T§ Rai -Subject- Engineering Certification fore the -State. of California: Structur'si. -d �"d d t'bIf b Sola .0sproy'. engineering . or. 0 oto Certification.and,Spap, h voltaic Rix ing-System,.as presented inT8t Aeport.# 2017=00240 05 trigi Tables-ftirtho SnapNr'ack L;itea'Rail Racking Systeirn"All infdrrhation. data, and aniilySis'tfie rein are based oq,,and comply with, the following building codes and Engineer yo Building Codis:; 1. ASCE/SEI 7 -10, -Minimum Design Load! for _Buiild ihgs and OtherStructures; by American '502ZS=riseBhrd. society gine rs .,Pyjl I Eh 0" CA 05628 .. F_ ,Z-7201.1'61U'4I1[fbt-ii3.Billdii, Building d—dL,.,bV,Califdr'h"i"aBolding ding-Standards. Commission `5364260 (lao 2016 cali6nia'ResidentiaiC4de;. by California,building.Standards Commission �4: AC428;.Acceptance 'Criteria fo;tMbdUlar'Ft4mirig: ste'rns-Use4toSupp. PhotovoltaicMal. &)-Panels, November 1, 2012 by I[CC-ES. 5. 416minurn b&ig-1 Manual 2000, byyiihe Aluminum O um Asciaboh, Inc.- A- % .. I 64 ANSI/AWC 46S-2615jWaetonaf Design Specification -for Wood: Construction, by,the;, ,Ain6rj6,hWoL6d Council Design e eria: 'Risk Category IV. Norman Sthee4SX. Seisrhic Design Category =A E, O&D#C ' Bas !c, WindSp tiltiMki) per ASCE 7,10' 110 mph to -190 mph: Qhi�46AOC' Ground Sn&k Load 0 -to 1.20 This Iiitt& certifies ihat-th6-1oa'dihg'ciffiria-ind-deii `.64sis fQr:th '-Sfi_a0Nra'& UltraFlail Flijih-Mbuhi system Span Rob Coon gn e:_ Tdbl6s'are in c6tribliah6gwith the '66bve codes.. s.: Steve SmIth Px. If y6.q h ­ Prepared by:, Inc. = Strut , tu n§ 1. E i.. ineers 4ackle Vinslow office Matmgcr Snc1,cArack-,Pv, 11idt'l#n' 775FieroLane,-Suite'200 San Luis Obi*, 6,k 93401 kii: spapNracJi Metal Roof:Bsse Andes of tests were conducted on the SnapNraj*_,-p4eW. Roof Ekise to detennine-thid attachment strengthcnt) .. and the integrity, (401mal load and mom y. ,'of the ,'two rubbiT seals under varying temperature and pressure conditiPusne- two tests are described as follows:. 'Teit 1- Normal Load Testing The aftacbmUnt strength testing was performOd'wiihaiFirst Article Roof Base sample&id to We teist,hitiinai' Ile WA -was .conducted to deiermine the normal load ffiture point TOt 2 - Mpmeri't Tcstu►g For the momcut testing.a-2" section of standoff was atticheidj6 the First Article Roof But: sample. 11 ieirnoment' . test was. conducte . d;to 'determine thiiirisaimum , �, &fluiv moment POM Roof biases, produ* by SnapNrack to be an acceptable device for secunng.- solar panels t . o a.roof with Snsp�*ack Series 100 or othersimilar solar panelm omfing systems.." The results for the three tests -are slummarized in the table. below. Test 1. Test 2 Norrh-a],Load Test MomentTest Value Values Obs) _lbs)' _Ultimate Allowable- Ultiinat6 A116w6ble 4,011 -2,008. !91 73 O LLJ M NdriAah-Stheel P SE� Cn L-EED -AP BD+C-, LEED -AP Homes Fellow,SEAOC Tellow-A,Sii,bA UMMMOESIGN S13LAR I PHONE: (530) 345-0005 1 SO�Niack ur6anbesign Solar; Inc: 116b P�rk Av'e'j1'u6- :Chlco,-CA 959.28' 'idkense 4993826 B C-46 ENGINEERING LETTER JAN 1 '03 '120 1d PROJECT I DRAWN ENGINEERING LETTER (RACKING) 11Q - �11 SCALE: NTS -I PV42 CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. C%4 O LLJ M Cn U-1 Uj LO C/) M — (73 >_ Cn Uj C/) Uj LL_ C1 Of LU LU otf Uj C) U-1 Ne U C) Of -LU :a (530) 321-9269 ur6anbesign Solar; Inc: 116b P�rk Av'e'j1'u6- :Chlco,-CA 959.28' 'idkense 4993826 B C-46 ENGINEERING LETTER JAN 1 '03 '120 1d PROJECT I DRAWN ENGINEERING LETTER (RACKING) 11Q - �11 SCALE: NTS -I PV42 - MID CLAMP ASSEMBLY 1 1,__ --- SS BONDING PIN -�_ - MODULE FRAME / RAIL - CHANNEL NUT NOTE: 1. ADJUSTABLE END CLAMPS USE SAME BONDING PIN DESIGN TO BOND MODULES TO RAIL. 6-12 AWG BARE 5/16"-18 SS BOLT COPPER WIRE SS SPLIT LOCK WASHER (TORQUE TO 16 FT-LBS) / SNAPNRACK GROUND LUG I � \ / CHANNEL NUT RAIL SS BONDING PINS NOTE: 1. ALL HARDWARE IS INCLUDED FROM MANUFACTURER 2. A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY CONTINUOUS ROW OF MODULES 3. GROUND LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL ASSEMBLER: 4. GROUND LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL OR PERPENDICULAR TO RAIL 5. ENSURE SPLIT LOCK WASHER IS INSTALLED ON-TOP OF COPPER WIRE INSPECTOR: DESCRIPTION: DRAWN BY: MIKE WATKINS SNAPNRACK MOUNTING SYSTEM APPROVED BY: CODY NORMAN SnapNmck REVISION: GROUNDING DETAILS. G 1/11/2016 NEW rrEM Solar Mounting Solutions' Sunrun South LLC 595 MARKT STREET 29TH FLOOR • SAN FRANOSOO. G 9410.5 USN PART NUMBER: - - SCALE: - - PHONE (415) NO 6999 • FAX (415) 5996902 , DNS �, ,�a,��A 4 m�,�.,�:. A� . REP0.000CilOM, dSCIOSME OR 1AE iNEREOi I9 n Nlnqur THE - .. - xmrtv+corsFxr oc sARun sarin 1/c. ' URBANMDESIGN !SOLAR URBAN DESIGN SOLAR PHONE: 530 345-0005 URBANCCMDESIGN 50[.AR URBAN DESIGN SOLAR PHONE: 530 345-0005 LICENSE NO. 893826 B C46 CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. N r � U Q ch W w ~ rn Cn C/) Wui LL_ U W Y OU. _ H W O J r__ _ Lu (530) 321-9269 CONTRACTOR OF RECORD [Trban`Design Solar-tli_ic:. 2260 Fark avenue iChic,o; C-A.9S928" License 4893826 B; ,C-46 RAPID SHUTDOWN PROJECT NO: GSD -20180222-82258 DRAWN BY: SCM DATE: 212212018 RAPID SHUTDOWN DATASHEET - \/ 1 d SCALE: NTS P Y 1 1 `: r. ------------- Ic r ';i Gor'x07l�B�l•��db�, � , Y i Bela Ted 4B ewe �te�s'! SO E''5kC32TT9 �luii� 2fi, X19+3' ; ', Ido i0i7'O C1t%001 J 2 e 204 . , .. :v - .: ,. <. . - �• �i�j�,ct 6Va 13#A1.7�3554' - �!'Sf h'S�T ts" ,_ '` ' . � �Rtk 2.9.57 SFfl'��'. �' ' igac � '' k,' �Ah ilius;• , 0 3E�XiS/9€Ldl(4�Sj OKUSmom rg#h®Semi£dgeraplds aibdoVrnwb�eI bel�d,htCb x-.. Tara?ti�slapi�L�d� s' r:a .•p- _ � .. _ .- �'v��p�itoi<�3t3'Et�Ens�iil�inil�invrS��ty�tsFswlisry'a®aetia.+e�is - p�te���i��L• ' HO D'AMKAiiOX: I9?i%AEL• , • .. , r 'ff•J 1 - ♦�'..3. �,. , - L. _.- r_ ��F�-FnfiitbxrArFt�►�'�'r �rt:nutn�t�1' ¢n�/ tre�o91�'�4d !oy k0gF ' � ;.�@,;u e� �dlp Iu�_ a ta:iJi�C FSI•, .� RmquFar�� - � a ' { �iitiel[s31�t �a Ottt n SIMS c Gf Iu on t vbt8t 9y 1rt eh E?igj Nq t0 5S4: i,` 1 N1r`M�liia� .• •. ,- - .,•, :.:: •,:..t n.-. • . r 'i5t °fin, it QR ars t ml ;gL 1i4TIP.tl#� iil � 1t3R0? 4i �iq}f bi iil !` 4$hf4 i�Fi 1 Q1t y lF s�rita #Fm.itaaf ta:tra� ltf lagu9rti cra#�msd fallmvli .. R I sport I€.tet'eTria moi: , ; 0 _ Q --fit fiQfi �� sar 4iia u Qt= fi�fac�e k ca cs9on i A lnv_ n b�:e�e�€,aeSO� d q�fQP�A44r �U�f+�n`S�st�ra , SR .s O,�Jihi ;b3ti11I3Yr4$k dQ�sTeWW*6911.td;ytil`is' U' aih.' P€OQ'F <IAF€Ate,.L _ - � . ,-,� • . Gpritpib(eFl lYy R1Fa:Pt 1�1�v5 by: prd U �i �+� �inaerr��e�rn l tl 1 •.. �' .ar s , '�i�5riat��i �SiQj1'�`t,9•ir�t $""``.` �'im Vffit k1F E imnr�c�j� orF�piln+ m tiIT v 'ivl pari tmb�rsllst 6 co.•• _) IQ�4� �n e�JUiirt .: �7� l3�tex201 4t •Au lis ihArodu�hsns:le (i�njtl:tAitiri9 ttns9t-, G.' POW T, P3UFFI"FFi.' 4 '•cpBt/i'xii�; �dli2rti i# a number, u�9;p �$ aImu�r► vaiF�2.�lhi2rgr3 g5�y y�ly, - �uiri.b i nfTFf;:Oftfi. $$ isoiinyetlnkbtFiti'�'ri ifoff9-d him m.' a .• GF i .3/ 12 ,3QDC i91/. GP�#ia Y M-WTV, vft. [u 3aCt:.1$ .`ii'iy fMMb9T,-V-9t: �c ; Patto, ish� l�dd,'I�e2;.?![�.aaa, �l'h cam, add,' c+.�F± is pnyt Fls.�mbers SDA Bea a rr�s�m . uptox�cS,=3,at4Famrftrn,;ncya�it5lroyn�Fnli��;,1�9�ElmvcnuFto': sE760 / s ►a 11�'.90if:9 wher�t5ifl !a +a3d'siiavimbft3 ha�e�Ind °1�E�- •.ice i�, pit= t -�i�d���.r�siFts���xlBttitEl�6re�rtl�rS�r+Sf{rS�v�i�sfi�•1�.a'r�eturst#�r.c .' � . -. �•taw,�r6er-.paTsnurii�rmay�bgtalla,�a:sc�c_ � � _ • . ;. ,� j - +'.: �, ....- i t ti • 1:1Mlirlllm�s. �ee�+aadl`4�'t,dE �HllepieC�!'t f^�$ilCby��,.,�i�a, fdH., .ICkGS kt.•tO fl$7l18d�d�pllJi7��'hz`l§feL.. ,.OMstl1E1T16U`9��6i1s'x#�i1M b 6Lud�5bBa�lsrk E�d�1$oLY'eq�ItmAo �1ci:�/�L{Y� tlOkrfaOct.�Y�C1hbla;[h49di�d/sttidfiihx9:te5ab6r1eA$r.®t"Fe,'(�yq ntwix,c�►i�goraatlie'r�1ft '•msk6ft�l.,diitOl�N m7t6f�1,(+�it9!wtii�1 !!r{S .. Gm faa5-iSrptV.1A1+,PEx6ti's�NA CrNe'r1fikF�1A�'+tr.A�aiH7:1#�laigj:'WtiIRls�91JM •'IEy�rit0#"iidildf2'IA91tpy�it EU fN�W.�El1Syb'iSS6litYil#ltl�ilbk�1 W10Yil1 h'G�WD:IiOitAliNri jziij9r�:r ♦ .. - • . . ' „ ° -\ ti' •.� It � 11"�,•:c ,; � '` -rj :Plq�b�i1�• t � � u t�s`s`aDc : w ♦ orate. -14 t � s . . • :� Itni�t+ 1Ct�Ll1�., 'v. - � .. ._. �-. � 1'�i� �1'1t1�b1 I�dr�+i�',6 - =e�,1�,�.aS,v F?!44�— _ _ _ _, _ - -- - �-1�.�'t1TM�l�'iR ir�ra .. 1.,,. � h., � ,.:,. . .... . ,�.. . . . � URBANCCMDESIGN 50[.AR URBAN DESIGN SOLAR PHONE: 530 345-0005 LICENSE NO. 893826 B C46 CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. N r � U Q ch W w ~ rn Cn C/) Wui LL_ U W Y OU. _ H W O J r__ _ Lu (530) 321-9269 CONTRACTOR OF RECORD [Trban`Design Solar-tli_ic:. 2260 Fark avenue iChic,o; C-A.9S928" License 4893826 B; ,C-46 RAPID SHUTDOWN PROJECT NO: GSD -20180222-82258 DRAWN BY: SCM DATE: 212212018 RAPID SHUTDOWN DATASHEET - \/ 1 d SCALE: NTS P Y 1 1 `: r. ------------- Ic • FAIT N Powering Business Worldwide r General Duty Cartridge'Fuse Safety Switch DG222NRB UPC:782113144221 Dimensions: • Height: 7 IN • Length: 6.41 IN • Width: 8.4 IN Weight:9 LB Notes:Maximum hp ratings apply only when dual element fuses are used. 3 -Phase hp rating shown is a grounded B phase rating, UL listed. Warranties: • Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. Specifications: • Type: General Duty/Cartridge Fuse • Amperage Rating: 60A • Enclosure: NEMA 3R • Enclosure Material: Painted galvanized steel • Fuse Class Provision: Class H fuses • Fuse Configuration: Fusible with neutral • Number Of Poles: Two -pole • Number Of Wires: Three -wire • Product Category: General Duty Safety Switch • Voltage Rating: 240V Supporting documents: • Eatons Volume 2 -Commercial Distribution • Eaton Specification Sheet - DG222NRB URBANDE916N 913LAR URBAN DESIGN SOLAR pe.eaton.com PHONE: 530 345-0005 LICENSE NO. 893826 B C46 CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING SET IS CONFIDENTIAL AND SHALL NOT BE DISCLOSED IN FULL OR IN PART TO ANYONE EXCEPT THOSE INVOLVED IN THE DESIGN AND INSTALLATION OF THE PV SYSTEM REPRESENTED IN THIS PLAN. CV O w . in W z LU U C/) C or_ O >_ CnLLl Q U:)Lu Lam.Of UJI U W cifw Y 0 C� z (530)321-9269 CONTRACTOR OF RECORD r.bar- De51gn SO14rJAC: _2 60 PAAAY