Building Permit Number: B17-2284 Plan Check #1
Description: Bathroom and Deck Addition and Remodel
Occupancy Classification: R3% U
Construction Type: " VB
Stories: 1
Fire Sprinklers: ?
Building Total Area: 79 sf
T: 530.538.7601
F: 530.538.7785
buttecounty.net/dds
surra
covNff
DEC 0 4 2017
DEVELOPMENT
SERVICES
Thank you for submitting permits for your building project. The permit documents have been reviewed
and comments are listed below. Please respond in writing to each comment. Complete and clear
responses will expedite the re -check and approval of this project. Please provide two revised plan sets
with your response.
GENERAL COMMENTS:
Amend the plans to indicate the following on the cover sheet.-•--�.... �.
B. Occupancy Group(s) (dwelling = R-3, garage = U) (Plans currently say R-1)
C. Fire Sprinkler system (indicate yes or no)
D. Square footage of the new deck too. Seems it is around 530 Sq Ft
XUpdate the scope of work on the cover page to include the new deck. Gj
Label all the rooms in the floor plan. What is the room in-between the dining rm and bedrooms?
ARCHITECTURAL COMMENTS:
Amend the plans to indicate the following for stairways. C.R.C. Section R311.7. S �/
A. Stair riser height shall be not more than 7.75 inches. C.R.C. Section R311.7.5.1.
B. Stair tread depth shall not be less than 10 inches minimum. C.R.C. Section R311.7.5.2.
Handrails shall be provided on at least one side of each continuous run of treads or flight with
four or more risers. C.R.C. Section R311.7.8
Amend the plans to indicate the following for the handrail:
A. Handrail shall be not less than 34 inches not more than 38 inches above the stair tread nosing.
C.R.C. Section R311.7.8.1.
i
r
L� c-, Y,Y
i
The clear space between a handrail and a wall or other surface shall be a minimum of 1.5 inches.
C.R.C. Section R311.7.8.2.
C. Handrails shall be continuous. C.R.C. Section 311.7.8.2
fHandrail assemblies and guards shall be able to resist a single concentrated load of 200 pounds,
a, l� applied in any direction at any point along the top, and have attachment devices and supporting
structure to transfer this loading to appropriate structural elements of the building. C.R.C. Table
R301.5 footnote d
Amend the plans to indicate smoke alarms outside the existing bedrooms. C.R.C. Section R314.3.
Add a note on the plans that lots shall be graded to drain surface water away from foundation walls. ) Z
The grade shall fall a minimum of 6 inches within the first 10 feet, 5%. C.R.C. Section R401.3.
CALGREEN COMMENTS:
9. Please provide a Construction Waste Management form. CalGreen Section 4.408.. d1,vn.•1W'
Please submit a (2016 CalGreen) Residential Mandatory Measures Check list. B
• r
STRUCTURAL COMMENTS:
1. Please comply with the conventional light frame construction (bracing) requirements of the 2016
ACalifornia Residential Code (CRC) Section R602.10 and identify wall bracing on the plans or provide �lot1
a lateral analysis of wind and seismic forces prepared by a registered design professional (i.e.�
Engineer or Architect). The notes and details on the plans reference a bracing schedule and a
shearwall schedule but neither are provided on the plans.
2. Provide complete deck framing plans. Clarify orientation ofj*oisq and specify siz a d locations of4,51
deck girders and footings required. i �y�,tl� `I 14
3. Please provide deck lateral load connections in accordance with 2016 CRC R507.2.4. Tension
�S
devices shall be installed at no less than 2 locations per deck and each device shall have an allowable
stress design capacity not less than 1500 pounds. See suggested deck attachment for lateral loads
detail (2016 CRC Fig. 507.2.3) attached.
OAJO Specify the number, size, and type of stair stringers and their attachment to the deck and the
foundation.
The Department of Development Services is currently open to the public from 8:00 am to 4:00 pm. If you
wish to discuss these plan check comments, please call during our business hours or contact us by e-mail
at the address below. Permit status can be tracked by logging on to http://www.buttecounty.net/dds and
clicking Building Permits Status.
Efrain Ruvalcaba
Plans Examiner
530.538.2875
eruvalcaba(a,,buttecouu .net
Philo Hunt, P.E.
Plan Check Engineer
530.538.2130
ph unt(a b uttec o unty me t
2 `t
FIOOR'$HEATHING NAILINGAT;.
6IN MAXIMUM OKCENTERTO
JOIST WITH HOLD.00WN'
FLOQR JOIST -J L 'DECKJOIST