Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
GRUBBS RESIDENCE
.. Ilk GRUBBS RESIDENCE ` a—fir, li �b3il 4 4927 E - N METERED 2.750 kW PV vi ginla A enue ' i m :w DATE: 7/26/2017 I � APPLICABLE CODES / NOTES: THIS SOLAR PHOTOVOLTAIC SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS SPECIFIED IN ARTICLE 690 OF THE 2016 CEC AND ALL APPLICABLE BUILDING CODES.(REFER TO PAGE 6) G) z D- D m SYSTEM SPECIFICATIONS: MODULE: CANADIAN SOLAR CS6K-275M (10 MODULES) STRING - INVERTER: ENPHASE M250-60-21-1- MICROS AZIMUTH(S): 180° TILT(S): 18° BUSBAR RATING: 125A MAIN BREAKER: 125A ATTACHMENT TYPE: UNIRAC PV COMP SHINGLE MOUNT G) z D- D m TABLE OF CONTENTS DRAWN BY: P.1 COVER SHEET ' J B H P.2 - SITE PLAN P.3 MODULE LAYOUT REV. P.4 MOUNTING DETAILS P.5 ELETRICAL SCHEMATIC _ P.6 ELETRICAL NOTES P.7 STICKER / PLACECARDS 4927 VIRGINIA AVE OROVILLE, CA 95966 ° CLIENT PHONE # 530-592-8377 3760 MORROW LANE SUITE D JURISDICTION: CHICO, CA 95928 CITY OF OROVILLE 1(855)360 -JOIN UTILITY: LIC #: 1021484 PG&E . TABLE OF CONTENTS DRAWN BY: P.1 COVER SHEET ' J B H P.2 - SITE PLAN P.3 MODULE LAYOUT REV. P.4 MOUNTING DETAILS P.5 ELETRICAL SCHEMATIC _ P.6 ELETRICAL NOTES P.7 STICKER / PLACECARDS MOUNTING CLIP, TYP - 1 1-r1 r1 T SOLAR MODULE UNIRAC STANDARD RAIL \ � ■ 6'''M"AX i RAFTER OR TRUSS ROOF TILT: 18 ° ' (2) 5/16"0 x 4" .OR 4 1/271 18-8 SS, -LAG -SCREWS, TYP. 2,1/2" MIN. EMBEDMENT LOADING: RAIL MAXIMUM ALLOWABLE SPANS PROVIDED BY MANUFACTURER (SEE PAGE 3 FOR PROVIDED MOUNT SPACING) PER ASCE 7=10, SECTION 6.4.2.2 & FIG. 6-3 MAXIMUM UPLIFT: .6 D+W = 158 LB ,< 237 LB MAXIMUM DOWNFORCE: D+W = 218 LB < 237 LB WEATHER LOADING: RAILING: GROUND SNOW: 0 PSF UNIRAC • .WIND SPEED: 85 MPH STAND RAILING PV ARRAY: 2.75 PSF 3760 MORROW LANE SUITE D ' EXPOSURE CATEGORY: B MOUNTING: CHI CO,.CA 95928 '. UNI RAC PV 1(855)360 -JOIN. COMP SHINGLE LIC #: 1021484 PLYWOOD �- UNIRAC PV COMP SHINGLE MOUNT COMP SHINGLE ARRAY SELF WEIGHT: MODULE: 40.8 LB OVER 17.3 SF = 2.35 PSF RAIL: 0.54 PLF; (2) PER 64.5" MODULE = 0.2 PSF MISC: CLAMPS, HARDWARE, WIRING, ETC. .=,0.2 PSF ARRAY SELF -WEIGHT =.2.75 PSF MAX WEIGHT PER ANCHOR =44.6 LB (FOR 4'-0" SPANS) TABLE OF CONTENTS . P.11 COVER SHEET P.2 SITE PLAN P.3 MODULE LAYOUT P.4 MOUNTING DETAILS P.5 ELETRICAL SCHEMATIC P.6 ELETRICAL NOTES P.7 STICKER / PLACECARDS MVA NUFACTURERL APPROVED CANADIAN SOLAR MODEL CS6K-275M INVERTER - UL APPROVED MANUFACTURER MODEL ENPHASE M250 ELECTRICAL SPECIFICATIONS' DISCONNECT ELECTRICAL SPECIFICATIONS - ~ RATED POWER OUTPUT @ STC 275 RATED AC VOLTAGE 250V OPEN CIRCUIT VOLTAGE (Voc) 38.3V CEC EFFICIENCY. 96.5%. MAX POWER VOLTAGE (Vmp) 31.3V MAX POWER OUTPUT @ STC 240W SHORT CIRCUIT CURRENT (Isc) 9.31A MAX INPUT VOLTAGE 48V MAX POWER CURRENT (Imp) 8.80A MAX INPUT CURRENT 15A Voc CORRECTION FACTOR (%/deg C) -0.31 % MPPT VOLTAGE RANGE 183V - 229V Vmp/Pmp CORRECTION FACTOR -0.41% MAX OUTPUT CURRENT 1.OA TO UTILITY GRID lJ 120/240V SINGLE PHASE T MAIN RESIDENCE NOT CENTER FED PANEL BI-DIRECTIONAL UTILITY METER (N) 20A 2 POLE BREAKER:- SHALL REAKER'SHALL BE INSTALLED OPPOSITE MAIN BREAKER SYSTEM OVERVIEW— # OF MODULES IN SERIES (CIRCUIT SIZE) 10 # OF MODULES IN PARALLEL (# CIRCUITS) 1 NUMBER OF MODULES PER INVERTER 1 ARRAY RATED DC POWER OUTPUT STC 2.750 kl #6 CU AWG BARE WIRE (TYP) BOUNDING MODULES & RAILS J- BOX UNDER ARRAY SEALED TIGHT NON-FUSED -NEMA TYPE3 MIN. ENVOY S XAM1-120M COMBINER BOX EATON 30A AC. DISCONNECT I�MAIN,ELECTRICAL - ~ PANEL(E) �-' J - 125 120/240V o — —= {' �IIII� MICRO -INVERTER III MICR04NVERTER#2 TER#9 MICR04NVERTER#10 ERTER (TYP.) ®LLI ®° CI MICRO -INVERTER TRUNK CABLE, 1 PHASE . Ev0© 900c, 60OV, WET/DRY, WITH MICRO -INVERTER. I PRE-INSTALLED CONNECTORS OPEN AIR C� CONDUCTORS, NOT IN A CONDUIT BLACK -L1 RED-L2,WITH-NEUTRAL GREEN -GROUND ELECTRODE MIN. 6' APART UL1741, UL 746 C,F1, IEC'60529 IP67 (TYP) I - C� -i - u SYSTEM OVERVIEW— # OF MODULES IN SERIES (CIRCUIT SIZE) 10 # OF MODULES IN PARALLEL (# CIRCUITS) 1 NUMBER OF MODULES PER INVERTER 1 ARRAY RATED DC POWER OUTPUT STC 2.750 kl #6 CU AWG BARE WIRE (TYP) BOUNDING MODULES & RAILS J- BOX UNDER ARRAY SEALED TIGHT NON-FUSED -NEMA TYPE3 MIN. ENVOY S XAM1-120M COMBINER BOX EATON 30A AC. DISCONNECT - ~ - ~ 0 J - . o — —= {' MICRO -INVERTER III MICR04NVERTER#2 TER#9 MICR04NVERTER#10 ERTER (TYP.) CI MICRO -INVERTER TRUNK CABLE, 1 PHASE . 1 900c, 60OV, WET/DRY, WITH MICRO -INVERTER. I PRE-INSTALLED CONNECTORS OPEN AIR C� CONDUCTORS, NOT IN A CONDUIT BLACK -L1 RED-L2,WITH-NEUTRAL GREEN -GROUND ELECTRODE MIN. 6' APART UL1741, UL 746 C,F1, IEC'60529 IP67 (TYP) I - C� -i - MOUNTS AND EQUIPMENT 'ENCLOSURES GROUNDED • TO MAIN PANEL GROUND (E) LIFER GND COMPONENT CONNECTIONS WILL BE MADE WITH (UNLESS OTHERWISE SPECIFIED) EXTERIOR 2" EMT AC CONDUIT , OR INTERIOR ROMEX :10-3 (3) #10 CU THWN-2 (1) #8 CU GROUND ,. 90°C WET & DRY " BUSBARRATING:125A - MAIN- BREAKER:' 125A # OF MODULES: 10 SYSTEM SIZE (kW): 2.750 Y TERMINATOR CAP ON LAST CABLE CONNECTOR OF AC ` TRUNK CABLE (TYP) , 10 PANELS- BRANCH CIRCUIT #2 3760 MORROW LANE SUITE D CHICO, CA 95928 1(855)360 -JOIN LIC # 1021484 'TABLE OF CONTENTS P.1 COVER SHEET P.2 SITE PLAN - P.3 MODULE LAYOUT P.4 MOUNTING DETAILS P.5 ELETRICAL SCHEMATI( P.6 ELETRICAL.NOTES P.7 STICKER/ PLACECARD J -BOX - ~ - ~ ~ — —= AMICR.1-rR MICRO -INVERTER III MICR04NVERTER#2 TER#9 MICR04NVERTER#10 ERTER (TYP.) MICRO -INVERTER TRUNK CABLE, 1 PHASE . 1 900c, 60OV, WET/DRY, WITH MICRO -INVERTER. PRE-INSTALLED CONNECTORS OPEN AIR (N) 5/8" O MIN. 8' IN SOIL CU CONDUCTORS, NOT IN A CONDUIT BLACK -L1 RED-L2,WITH-NEUTRAL GREEN -GROUND ELECTRODE MIN. 6' APART UL1741, UL 746 C,F1, IEC'60529 IP67 (TYP) FROM EXISTING UFER - 3760 MORROW LANE SUITE D CHICO, CA 95928 1(855)360 -JOIN LIC # 1021484 'TABLE OF CONTENTS P.1 COVER SHEET P.2 SITE PLAN - P.3 MODULE LAYOUT P.4 MOUNTING DETAILS P.5 ELETRICAL SCHEMATI( P.6 ELETRICAL.NOTES P.7 STICKER/ PLACECARD - EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT - THIS SOLAR PHOTOVOLTAIC SYSTEM SHALL BE INSTALLED IN P06 PER MANUFACTURE'S REQUIREMENTS. ALL SOLAR MODULES EQUIPMENT, AND ACCORDANCE WITH THE REQUIREMENTS SPECIFIED IN ARTICLE 690 THE METALLIC COMPONENTS ARE TO BE BONDED. IF THE EXISTING OF THE 2016 CEC AND ALL APPLICABLE BUILDING CODES. GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A - ACCESS TO THE ELECTRICAL WIRE SHALL BE RESTRICTED TO SUPPLEMENTAL GROUNDING ELECTRODE. QUALIFIED PERSONAL ONLY AS REQUIRED BY ARTICLE 690 OF THE 2016 CEC. = ALL PLAGUES AND SINGAGE REQUIRED BY THE LATESTEDITION OF NATIONAL ELECTRICAL CODE. REFER TO SHEET 7 (STICKERS AND PLACECARDS). LABEL -THE PHOTOVOLTAIC ARRAY(S) SHALL BE PROVIDED WITH DC SHALL BE METALLIC OR PLASTIC, ENGRAVED OR MACHINED PRINTED IN A GROUND -FAULT PROTECTION. (CEC 690.5) CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL BE UV RESISTANT IF EXPOSED TO SUNLIGHT. - ALL CONDUCTORS SHALL BE TYPE 90 DEGREE C RATED. (CEC 690.318) - DC CONDUCTORS SHALL BE RUN IN EMT AND/OR MC (METAL CALD CABLE) AND SHALL BE LABELED, "CAUTION DC CIRCUIT" OR EQUIV. EVERY 5 FT.. - ALL EXPOSED PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE TYPE USE -2 OR PV WIRE. (CEC 690.31 B) - EXPOSED NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT - SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136 (A) - ALL CONDUCTORS SHALL BE TYPE 90 DEGREE C RATED (CEC - 690.318) CONFIRM LINE SIDE VOLTAGE AT ELECTRICAL UTILITY SERVICE PRIOR TO CONNECTING INVERTER. VERIFY SERVICE _VOLTAGE IS WITHIN INVERTER -THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING VOLTAGE OPERATIONAL RANGE. - AND INTERCONNECTIONS SHALL BE PERFORMED ONLY BY •- ' QUALIFIED PERSONS (CEC 690.4) - OUTDOOR EQUIPMENT SHALL BE NEMA -3R RATED OR BETTER - ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT"RUNS AS REQUIRED PER NEC: - ALL WIRING MUST BE. PROPERLY SUPPOTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED -FOR SUCH USE, AND FOR ROOF -MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF'OF ` THEROOFSURFACE. NEC 110.2-- 110.4 / 300.4 - ALL PV METERS TO BE WITHIN 5 FT OF ANOTHER. - - PV METERS TO BE INSTALLED. CORRECTLY, SUPPLIED FROM THE TOP JAWS. ' - ALL ROOF PENETRATIONS MUST BE FLASHED: -SIMPLY CAULKING DOES NOT - - SUFFICE. TABLE OF CONTENTS P.1 COVER SHEET P.2 SITE PLAN P.3 MODULE LAYOUT PA MOUNTING DETAILS 3760 MORROW LANE SUITE D P.5 ELETRICAL SCHEMATIC. CHICO, CA 95928 P.6 ELETRICAL NOTES 1(855)360-JOJN LIC #: 1021484 P.7 STICKER / PLACECARDS WARNING: ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDE MY BE ENERGIZED IN THE OPEN POSITION ' PLACED•ON-OR ADJACENT TO THEW PLACED ON THE INVERTER, -OR PLACED DISCONNECTING MEANS NEAR THE GROUND -FAULT INDICATOR t� AT A VISIBLE LOCATION 4.. ooh- o • "UMo -lot -- • PLACED NEXT TO THE SOLAR.BREAKER lIV. 5.7" f --- -- y ' 'PLACED ON OR ADJACENT TO`THE .�• " DISCONNECTING -MEANS + , LOCATED ON,THE DC DISCONNECTIle DPORTION OF, THE INVERTER O WLm L}<' cuff numnymc gV .95" t - s � `a -t • .' y w..w t 1 •• � • 2 b21 511 v 0 . t • O D D' C�f1r\ D D 1 0 • s ,. - 4 i a Y i_ i .6"211 '211 T rj�/J 1 s 1 LOCATED ON MAIN. SERVICE PANEL •.`.: • ' _ _- �r� _ _ e ` lot it 1 NOTE: STICKERS ARE WHITE LETTERS ON RED BACKGROUND, ti TABLE OF CONTENTS P.-1 COVER SHEET - ° P.2 SITE PLAN STICKERS AND PLACECARDS P.3 MODULE LAYOUT _ 4 i 37so.MORROW LANE SUITE o P.4 MOUNTING DETAILS M CHICO, CA 95928 P:5 ELETRICAL SCHEMATIC . (855)360-Joiry 1 P .61 ELETRICAL, NOTES LIC #: 1021484 1 P.71 STICKER / PLACECARDS