HomeMy WebLinkAboutJB-9597588-00ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A .z AMPERE AC ALTERNATING CURRENT BLDG BUILDING CONC CONCRETE DC DIRECT CURRENT. EGC EQUIPMENT GROUNDING CONDUCTOR " (E) EXISTING' EMT ELECTRICAL METALLIC .TUBING t FSB FIRE SET—BACK ' GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GND GROUND HDG HOT DIPPED GALVANIZED ' CURRENT ' Imp CURRENT AT. MAX POWER ;. > Isc- SHORT CIRCUIT CURRENT kVA KILOVOLT AMPERE y - kW KILOWATT LBW LOAD BEARING WALL MIN MINIMUM (N) NEW ' NEUT NEUTRAL NTS NOT TO SCALE OC ON CENTER PL PROPERTY LINE POI POINT OF INTERCONNECTION PV PHOTOVOLTAIC " SCH SCHEDULE S STAINLESS STEEL STC STANDARD TESTING- CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY ' V, VOLT Vmp . VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT Sheet 1 COVER SHEET Sheet 2 PROPERTY PLAN Sheet 3 SITE PLAN GENERAL NOTES Sheet 4 Sheet 5 STRUCTURAL VIEWS UPLIFT CALCULATIONS LICENSE 1. ALL WORK TO BE DONE TO THE 2016 MEMANE Sheet 6 Cutsheets THREE LINE DIAGRAM . Attached CA # 888104 C-10 CALIFORNIA BUILDING CODE, 2016 CALIFORNIA _ PLUMBING CODE, 2016 CALIFORNIA RESIDENTIAL CODE, AND THE 2016 CALIFORNIA FIRE CODE. r 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE AS AMENDED MODULE GROUNDING METHOD: ZEP SOLAR BY THE 2016 CALIFORNIA ELECTRIC CODE. 3. SMOKE AND CARBON MONOXIDE DETECTORS REV BY DATE COMMENTS AHJ: Butte County REQUIRED. REVA NAME DATE COMMENTS UTILITY: Pacific Gas and Electric Company CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR JOB NUMBER: J B- 9 5 9 7 5 8 8 O O PREMISE OWNER: ROSA MCCANN DESCRIPTION: Rosa Mccann RESIDENCE DESIGN: Alonso Ortiz —r- S L MOUNTING SYSTETI: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 422 SIMMONS RD 14.1 KW PV ARRAY = ri PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION MATH OROVILLE CA 95966 , MODULES: J THE SALE AND USE OF THE RESPECTIVE (47) TRINA SOLAR # TSM-30ODD05A.18(II) APN: * EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV DATE - INVERTER: PERMISSION OF TESLA INC. PERMISSION Multiple Inverters COVER SHEET 1 0 11/14/2017 10' s 534 —11" PROPERTY PLAN \ j Scale: 1" = 20'-0'2 • 134'-s" p 20' 40' s CONFIDENTIAL -THE INFORMATION HEREIN JOB NUMBER: JB -9597588 00 PREMISE OWNER: DESCRIPTION: DESIGN: ' CONTAINED SHALL NOT BE USED FOR THEROSA MCCANN Rosa Mccann RESIDENCE Alonso Ortiz T S S L 171 BENEFIT SHALL ITOF ANYONE BE DISCLOSED ISN WHOLE OR IN T TESLA INC., NOR MOUNTING SYSTEM: 422 SIMMONS RD 14.1 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S ZS Comp V4 wFlashing-Insert ORGANIZATION, EXCEPT IN CONNECTION WITH MODun. OROVILLE, CA 95966 THE SALE AND USE OF THE RESPECTIVE (47) TRINA SOLAR # TSM-300DD05A.18(II) TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: NAME SHEET: REV: DATE PERMISSION OF TESLA INC. Multiple Inverters PROPERTY PLAN 2 0 11/14/2017 y� 10' s 534 —11" PROPERTY PLAN \ j Scale: 1" = 20'-0'2 • 134'-s" p 20' 40' s CONFIDENTIAL -THE INFORMATION HEREIN JOB NUMBER: JB -9597588 00 PREMISE OWNER: DESCRIPTION: DESIGN: ' CONTAINED SHALL NOT BE USED FOR THEROSA MCCANN Rosa Mccann RESIDENCE Alonso Ortiz T S S L 171 BENEFIT SHALL ITOF ANYONE BE DISCLOSED ISN WHOLE OR IN T TESLA INC., NOR MOUNTING SYSTEM: 422 SIMMONS RD 14.1 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S ZS Comp V4 wFlashing-Insert ORGANIZATION, EXCEPT IN CONNECTION WITH MODun. OROVILLE, CA 95966 THE SALE AND USE OF THE RESPECTIVE (47) TRINA SOLAR # TSM-300DD05A.18(II) TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: NAME SHEET: REV: DATE PERMISSION OF TESLA INC. Multiple Inverters PROPERTY PLAN 2 0 11/14/2017 PITCH: 34 ARRAY PITCH: 34 MPl AZIMUTH: 120. ARRAY AZIMUTH: 120- M ATERIAL: 20MATERIAL: Comp, Shingle STORY: 1 Story ' - - PITCH: 34' -, ARRAY PITCH:34 ' MP2 AZIMUTH: 300 ARRAY AZIMUTH: 300 MATERIAL: Comp Shingle STORY: 1 Story { PITCH: 34 - ARRAY PITCH: 34 *. MP3 AZIMUTH:300 "ARRAY AZIMUTH: 300 Front MATERIAL: Comp Shingle STORY: 1 Story sv LEGEND I I opl \I:dW �'�� IW Q (E) UTILITY METER & WARNING LABEL �I" = h I I INVERTER W/ INTEGRATED DC DISCO chI RSD I°0 WI i Inv & WARNING LABELS I I I v�I SD IT © DC DISCONNECT & WARNING LABELS L — — — —— • - — — — — — — — — J p0I iO3 © AC DISCONNECT &WARNING LABELS • t " Zd W Inv DC JUNCTION/COMBINER BOX & LABELS L—_ 3' F� MPT -------- N ------------ --1w 0 DISTRIBUTION PANEL &LABELS wl RSD RSD — — - — 3' FSB — — — — — Inv LC Lc LOAD CENTER &WARNING LABELS WI ° IM DEDICATED PV SYSTEM METER IN OM 0 I IM Rso RAPID SHUTDOWN LH O STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR 7h --- - CONDUIT RUN ON INTERIOR GATE/FENCE $V HEAT PRODUCING VENTS ARE RED r. � INTERIOR EQUIPMENT IS DASHED L -"J SITE PLAN " Scale: 1/8" = 1' 2 t . 0 1' 8' 16' CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: JB -9597588 O O PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE ROSA MCCANN Rosa Mccann RESIDENCE Alonso Ortiz T = 5 L n SHALLLLiT°BE DISCLOSED ISNiM OLE OTESLA R IN NOR MOUNTING SYSTEM: 422 SIMMONS RD 14.1 KW PV ARRAY _ PART TO OTHERS OUTSIDE THE RECIPIENTS ZS Comp V4 wFlashing-Insert ORGANIZATION, EXCEPT IN CONNECTION MATH MODULES: OROVILLE, CA 95966 THE SALE AND USE OF THE RESPECTIVE (47) TRINA SOLAR # TSM-300DD05A.18(II) TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET -REV DATE PERMISSION OF TESLA INC. Multiple Inverters SITE PLAN 3 0 11/14/2017 (E) MOUNTING PLANE (MP) TYPICAL PV SIDE VIEW- Sv Nrs PV MODULE 5/16"x1.5" BOLT WITH 5/16" FLAT WASHER ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP MOUNTING BLOCK ZEP FLASHING INSERT (E) COMP. SHINGLE (E) ROOF DECKING 5/16" DIA STAINLESS STEEL LAG SCREW (2-1/2" EMBED, MIN) (E) RAFTER SUBSEQUENT MODULES S1 STANDOFF INSTALLATION ORDER LOCATE RAFTER, MARK HOLE (1) LOCATION, AND DRILL PILOT HOLE. ATTACH FLASHING INSERT TO (2) MOUNTING BLOCK AND ATTACH TO RAFTER USING LAG SCREW. INJECT SEALANT INTO FLASHING (3) INSERT PORT, WHICH SPREADS SEALANT.EVENLY OVER THE ROOF, PENETRATION. INSTALL LEVELING FOOT ON TOP (4) OF MOUNTING BLOCK & SECURELY FASTEN WITH BOLT. PV MODULE - PV MODULE 5/16"x1.5" BOLT WITH 5/16"x1.5" BOLT WITH 5/16" FLAT WASHER INSTALLATION ORDER 5/16" FLAT WASHER INSTALLATION ORDER ' ZEP LEVELING FOOT - ZEP LEVELING FOOT LOCATE RAFTER, MARK HOLE LOCATE RAFTER, MARK HOLE ZEP ARRAY SKIRT - (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (1) LOCATION, AND DRILL PILOT HOLE. - HOLE. --- - - - - -- ----- - - - - ----- - - - - -- ----- - - - - -- ZEP MOUNTING BLOCKATTACH FLASHING INSERT TO ZEP MOUNTING BLOCK ATTACH FLASHING INSERT TO ZEP FLASHING INSERT (4) (2) MOUNTING BLOCK. AND ATTACH (4) (2) MOUNTING BLOCK AND ATTACH (3) TO RAFTER USING LAG SCREW. ZEP FLASHING INSERT (3) TO RAFTER USING LAG SCREW. (E) COMP. SHINGLE(E) SEALANT INTO FLASHING (E) COMP: SHINGLE , (1) (1) INJECT SEALANT INTO FLASHING '(E) ROOF DECKING (2) (3) INSERT PORT, WHICH SPREADS () E ROOF DECKING (2) (3) INSERT PORT, WHICH SPREADS SEALANT EVENLY OVER THE - SEALANT EVENLY OVER THE 5/16" DIA STAINLESS ROOF PENETRATION. 5/16" DIA STAINLESS ROOF PENETRATION. LOWEST MODULE SUBSEQUENT MODULES LOWEST MODULE SUBSEQUENT MODULES STEEL LAG SCREW STEEL LAG SCREW (2-1/2" EMBED, MIN)INSTALL LEVELING FOOT ON TOP (2_1/2" EMBED, MIN) INSTALL LEVELING FOOT ON TOP [(4) OF MOUNTING BLOCK & (4) OF MOUNTING BLOCK & (E) RAFTER SECURELY FASTEN WITH BOLT. (E) RAFTER SECURELY FASTEN WITH BOLT. #_STA N DOFF 1 + Scale: 1 1/2" = 1' _ • * S + Scale: 1 1/2" = 1' CoNFlowm — THE INFORMATION HERON JIae NUMBER:J B-9597588 OO PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE ROSA MCCANN Rosa Mccann RESIDENCE Alonso OrtizBENEFIT T S L n SHALL IT0F ANYONE BE DISCLOSED WHOLE OR INC.,T TESLA NOR MC sem: 422 SIMMONS RD 14.1 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS ZSSComp V4 wFlashing-Insert ORGANIZATION, EXCEPT IN CONNECTION WITH MODUS OROVILLE, CA 95966 THE SALE AND USE OF THE RESPECTIVE (47) TRINA SOLAR # TSM-300DD05A.18(II) 1. TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET: REV: DATE - PERMISSION OF TESLA INC. Multiple Inverters STRUCTURAL VIEWS 4 0 11/14/2017 • ` CONFIDENTIAL - THE INFORMATION HEREIN ' DESIGN SUMMARY , F 11.u.20117' Version #7110 �ossT�73eT; CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., Jobsite: S "Oijc Design Criteda'h, ROSA MCCANN �' Rosa Mccann RESIDENCE Alonso;.Ortiz' T L - Design,Code ,NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ' ZS Comp V4 wFlashing—Insert' ASCE 7=10 _..5 n . , : ;_, Impodanc ' Faetor, OROVILLE i CA 95966 ' ' • ' ` „c MODULES: ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE , (47) TRINA -SOLAR # TSM-30ODD05A.18(II) r Ultimate Wintl$p'eed= Eicposure Category • SHEET: REV.. DATE 110 mph C Fig. 1609A �SecU�on Ground Snow Load: PERMISSION OF TESLA INC. pg� UPLIFT CALCULATIONS 5s 0 1i/14/2017 ASCE Table 71-1 MPS e'e fid Dedi n I ifor ie lon MP NameM121 MP2- MP3. Roofing Comp Root C44niplRoot Comp'Root %3 Standoff' Comp'.MourA SRV Comp Mdilof SRV Comp'Mount SRV rn•, Pitch m= SLJRLL: PV' . 4LIRL1_.3Non PV 1. 1B:0 "O a80iP 160�p§f StandofffS p acro. ,and,La out_ MP. Name: MPT' MP2" MP3' fL' • � � t • + ' -X•Cantilever.. :24"'' 24" 24'' , ,. y * � „ a. +y -t . • 1: , `' # `� ` � � r _ .. t : , 38 39" • .. ; .. + � } Y ".. + * R ' -_ t . 1 �b a - ;W 040,11 48 All - X -Cantilever. 20"• 20" 20' o� Y S clog 64'Y 64" 64" %. ' , Y -Cantilever NA NA. Nk 'a -r1 'a l . +. • s �t - . Li i' _ , i . _ ` 'M r• \, d, ! `, L. 'r • to •, - . \ _ ' -. l -. j ' `_ •f -_ - %_ _ a�- ,� .... do s -,. .. - y �' •. 1 �` "�;o f - _ r,• 1. , a • ` CONFIDENTIAL - THE INFORMATION HEREIN ' DESIGN SUMMARY , F 11.u.20117' Version #7110 �ossT�73eT; CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., Jobsite: S "Oijc Design Criteda'h, ROSA MCCANN �' Rosa Mccann RESIDENCE Alonso;.Ortiz' T L - Design,Code ,NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ' ZS Comp V4 wFlashing—Insert' ASCE 7=10 _..5 n . , : ;_, Impodanc ' Faetor, OROVILLE i CA 95966 ' ' • ' ` „c MODULES: ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE , (47) TRINA -SOLAR # TSM-30ODD05A.18(II) r Ultimate Wintl$p'eed= Eicposure Category • SHEET: REV.. DATE 110 mph C Fig. 1609A �SecU�on Ground Snow Load: PERMISSION OF TESLA INC. pg� UPLIFT CALCULATIONS 5s 0 1i/14/2017 ASCE Table 71-1 MPS e'e fid Dedi n I ifor ie lon MP NameM121 MP2- MP3. Roofing Comp Root C44niplRoot Comp'Root %3 Standoff' Comp'.MourA SRV Comp Mdilof SRV Comp'Mount SRV rn•, Pitch m= SLJRLL: PV' . 4LIRL1_.3Non PV 1. 1B:0 "O a80iP 160�p§f StandofffS p acro. ,and,La out_ MP. Name: MPT' MP2" MP3' fL' X-SpAdit 77 72" =721' "W -X•Cantilever.. :24"'' 24" 24'' Y.S •' Wein ' 39:" 38 39" . aY-Cantilever_ NA, NA NA ;W 040,11 48 All - X -Cantilever. 20"• 20" 20' o� Y S clog 64'Y 64" 64" n .. , Y -Cantilever NA NA. Nk la out Not, .. '. e .Not-Sta `efed'; I Not Sta eied X:and Y' are;mawmumsthatare alwa [elative to ttie stiucture'framin ttiat'sii orts'the PV_ X isacioss "raftersand Y'is alon rafters:. •. 1 �` "�;o f - _ r,• 1. , a • ` CONFIDENTIAL - THE INFORMATION HEREIN ' DESIGN SUMMARY , F 11.u.20117' Version #7110 �ossT�73eT; CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., Jobsite: S "Oijc Design Criteda'h, ROSA MCCANN �' Rosa Mccann RESIDENCE Alonso;.Ortiz' T L - Design,Code ,NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ' ZS Comp V4 wFlashing—Insert' ASCE 7=10 _..5 n . , : ;_, Impodanc ' Faetor, OROVILLE i CA 95966 ' ' • ' ` „c MODULES: ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE , (47) TRINA -SOLAR # TSM-30ODD05A.18(II) r Ultimate Wintl$p'eed= Eicposure Category • SHEET: REV.. DATE 110 mph C Fig. 1609A �SecU�on Ground Snow Load: PERMISSION OF TESLA INC. pg� UPLIFT CALCULATIONS 5s 0 1i/14/2017 ASCE Table 71-1 MPS e'e fid Dedi n I ifor ie lon MP NameM121 MP2- MP3. Roofing Comp Root C44niplRoot Comp'Root %3 Standoff' Comp'.MourA SRV Comp Mdilof SRV Comp'Mount SRV rn•, Pitch m= SLJRLL: PV' . 4LIRL1_.3Non PV 1. 1B:0 "O a80iP 160�p§f StandofffS p acro. ,and,La out_ MP. Name: MPT' MP2" MP3' fL' X-SpAdit 77 72" =721' "W -X•Cantilever.. :24"'' 24" 24'' Y.S •' Wein ' 39:" 38 39" . aY-Cantilever_ NA, NA NA ;W 040,11 48 All - X -Cantilever. 20"• 20" 20' o� Y S clog 64'Y 64" 64" n .. , Y -Cantilever NA NA. Nk la out Not, .. '. e .Not-Sta `efed'; I Not Sta eied X:and Y' are;mawmumsthatare alwa [elative to ttie stiucture'framin ttiat'sii orts'the PV_ X isacioss "raftersand Y'is alon rafters:. .i •• _ s . • - - _ . - • .k. r - . � • w .. {tea r .. _ - .� - -• ` CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: JB -9597588 0 O PREMISE OWNER: DESCRIPTION: `� r1 CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., • ROSA MCCANN �' Rosa Mccann RESIDENCE Alonso;.Ortiz' T L MOUNTING SYSTEM: • ,NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ' ZS Comp V4 wFlashing—Insert' 422 SIMMONS RD �. 14.1 KW PV ARRAY _..5 n . , : ;_, PART TO OTHERS OUTSIDE THE RECIPIENTS OROVILLE i CA 95966 ' ' • ' ` „c .i •• _ s . • - - _ . - • .k. r - . � • w .. {tea r .. _ - .� - -• ` CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: JB -9597588 0 O PREMISE OWNER: DESCRIPTION: `� DESIGN: CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., ROSA MCCANN �' Rosa Mccann RESIDENCE Alonso;.Ortiz' T L MOUNTING SYSTEM: • ,NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ' ZS Comp V4 wFlashing—Insert' 422 SIMMONS RD �. 14.1 KW PV ARRAY _..5 n . , : ;_, PART TO OTHERS OUTSIDE THE RECIPIENTS OROVILLE i CA 95966 ' ' • ' ` „c MODULES: ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE , (47) TRINA -SOLAR # TSM-30ODD05A.18(II) r r . ? • . ' • SHEET: REV.. DATE TESLA EQUIPMENT, WITHOUT THE WRITTEN �� - ' PAGE NAME ' i - [INVELITER: PERMISSION OF TESLA INC. Ii Ie Inverters UPLIFT CALCULATIONS 5s 0 1i/14/2017 GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE OND (N)"#6 GEC TO (E) UFER AT PANEL IRREVERSIBLE Panel Number: TSM2020CFCU Meter Number: Inv 1: DC Ungrounded Inv 2: DC Ungrounded INV 1 — (1)InverDelt. ii 60OW 24Ov 97.5%�Ziibee PLC — (47) TRINA SOLAR &TSM.6W CA # 888104 C-10 i WITH CRIMP 1007923655 9 9 PV Module; PT ,40MM05A.18L) 30 ,270.6W PTC,40MM,ttiillk Frame,MC4,ZEP,1000V,Wht BckSht INV 2 Overhead Service Entrance Downsizing Main Breaker For Tie—In —(1 )Delta 1 Solivia 5.2 TL LABEL: B Inverter,520OW, 24OV, 97.5%, Zigbee, PLC Voc: 39.9 Vpmax: 32.6 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E) 200A CENTER -FED MAIN SERVICE PANEL MULTI -CONTACT - Delta N) 150A/2P MAIN CIRCUIT BREAKER Inverter 1 IND Branch Socket BRYANT _ 125A Load Center 7 1 _ N)150A/2P 12(N) 10 Delta Dc+ Solivia 7.6 TL DC- MPI: 1X10 tplj (E) LOADS 40A/2P_ "TN Li _ 27.V — — — — — — — — — — — — — — — — — — — — — — EGc — — — — — — — — — —.— — — — — • L2 DD+ DC+ 3 13 70A/2P N EGC DG 1 6 ., r — — — C' MPI: 1x9 C+ I 3 (3) A 1 a r, --———--———————————— ----- - - - - -- --- - L ---- --- — GEC -- DC+ TN DC - GND EGC— G MP3: 1x9 1 GC --—— — — — — — — —- ------------ --——— — — -- ——--------- I T • 1 (1)Conduit Kit; 3/4" EMT Delta I , Inverter 2 IND N 1 , 9 C 3 o 1 PLC— 1 11 Delta DC+ — — , , i Bolivia 5.2 TL DG MP2: 1x9 1 i 3OA/2P GEC + 1 u ____________ MULTI—CONTACT-----____-- _EGc—————————-—— ----� 240V — Branch Socket _ _ _ _ i L2 I DC+ TO 120/240V i N DG 1 4 a SINGLE PHASE , L � EGC --- DC+ DC+ c — UTILITY SERVICE 1 ---- ----------------------------------- -- TN DC- 4E�� MPT: 1x10 I -- — — — — — — — — — — — — — — — — — — — — - — — — — — — — — — — — —— — GEC -- GND __ EGC——————— — — — — A ——------- — — --------- G�------------- ----� 1 ( Kit; 3/4• EMT Voc* = MAX VOC AT MIN TEMP Ol 0 )GE # THQL2170 PV BACKFEED BREAKER Breaker, 70A/2P, 2 Spaces D (I)BRYAN ® BR4&125RP Load Center, 125A, 120/24OV, NEMA 3R AC B (3)Delta 1 Solivio Smart RSS Rapid Shutdown, 60OV, 20A, NEMA 4X, MC4 A (2)MULTI—CONTACT ! PV—AZB4 Branch Socket; C4 U—Joint Connector, Female Female Male DC (I GE # 1HQP230 BREAKER Breaker, 30A/2P, 1 Space )CUTLER HAMMER # BR240 Breaker, 4OA/2P, 2 Spaces C (2)Delta @ Solivio -(2)MULTI—CONTACT A PV—AZS4 Branch Plug; MC4 U—Joint Connector, Male Male Female — (1) GE i THQMVI50WL AIN BREAKER Circuit Breaker, 150A/24OVPiM - (1) CUTLER—HAMM g OR230 Breaker 30A2P, 2 Spaces Smari RSS Rapid Shutdown, 600V, 20A, NEMA 4X, MC4 K (2)AWG 110, PV Wire, 60OV, Block Voc* = 396.71 VDC Isc = 9.64 ADC (1)AWG 110, THWN-2, Green EGC Vmp = 293.4 VDC Imp= 9.19 ADC O 4 AWG 110, PV Wire, 60OV, Black Voc* = 396.71 VDC .. (1) AWG 110, THWN-2, Green EGC Vmp' = 293.4 VDC Isc = 19.28 ADC Imp= 18.38 ADC 2 AWG 110, PV Wire, 600V, Bladc O (1) WG #10, THWN-2, Green EGC Voc* =O 440.78VDC Isc = 9.64 ADC Vmp = 326 VDC Imp= 9.19 ADC (I)AWG 110, THWN-2 Black—(1)AWG 16, Solid Bare Copper GEC Ic?H (1) AWG 010, THWN-2, Red THWN-2, White NEUTRAL Vmp =240 VAC Imp=21.6 AAC 1 Conduit Kit; 3 4 EMT ....... �. ) gnoyit ... / �..MT ................... • (1) AWG 1B, THWN 2, Black (1) AWG 16, Solid Bare Capper f , THWN_2, Red (1)AWG 18 GEC `O 6 (1 Conduit Kit; 3/4• E]tT ....... . T ..... — (2)AWG 10, PV Vire, 60OV, Black Voc* — 396.71 VDC � � (1) AWG 110, THWN-2, Green EGC Vmp 293.4 VDC — Isc — 19.28 ADC — Imp= 18.38 ADC (1 Conduit Kit; 3/4• EMT. _•. 4 AWG 0, PV Wire, 60OV, Black 11 O ^' (1) AWG 0, THWN-2, Green EGC � � r91 . Voc = 396.71 VDC Isc = 9.64 ADC Vmp 293.4 VDC Imp= 9.19 ADC P = P= (1)ANG 110, THWN-2, Green EGC 1 Conduit Kit; 3 4 EMT -�))9'>A� �................... -(.) ........./. �.............. .... (I )AWG 14, THWN-2, Black — (1) AWG 16, Solid Bare Copper GEC 1 1 ( )AWG 10, THWN-2. White NEUTRAL Vmp =240 VAC Imp= _ ... - (1) AWG 18,. TFt.WN-2,_ Green .. EGC • • • - (1) Conduit. Kit;. 3/4• .ETdT... AAC _ .... • ... ... O 1 Conduit Kit; 3 4 EMT 2 ........./ �.................* ._ ...................... AWG 10, PV Wire, 60OV, Black Voc 440.78VDC �( ) # Isl— (I)AWG 110, THWN-2, Green EGC Vmp = 326 VDC Isc = 9.64 ADC Imp= 9.19 ADC (I)Conduit Kit; 3 4 EMT ........ �.) onduit t; / *EMT .............. (2) AWG 110, PV Wire, 600V, Black O (1)AWG 110, THWN-2, Green EGC ........... Voc* = 396.71 VDC Isc = 9.64 ADC Vmp = 293.4 VDC Imp= 9.19 ADC L.�LL (I )AWG THWN— , RED 0 Conduit Kit; 3/4•• EMT• ..... ..... (i Conduit Kit; 3 4 E7dT ). / '. (1)A% °Rfi9�1-11, White NEUTRAL Vmp =240 VAC Imp=53.3 AAC (1)AWG T1IY4E1-2,. EGC (1) C(1IDUIT KIT ® (2 AWG 110, PV Wire, 60OV, Black Voc* = 4'4'0'.7* 8* (1) AWG 110, THWN-2, Green EGC Vmp = 326 VDC Isc = 9.64 ADC Imp= 9.19 ADC (2)AWG 110, PV Wire, 600V, Black ® (I )AWG #10, THWN-2, Green EGC Voc* = 44 AVDC Isc = 9.64 ADC Vmp = 326 VDC Imp= 9.19 ADC - /8,. Green • . _ .. - T k • 1D• EMT Conduit • • • ' ' ' ' CONFIDENTIAL —THE INFORMATION HERON , JOB NUMBER: JB - 9597588 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE INC..T TESLA NOR ROSA MCCANN ROsO Mcconn RESIDENCE Alonso Ortiz . T = 5 L n MWNnrlc s»: [MoDun. SHALL ITBENEFIT D WHOLE OR ZSDISCLOSENE ZS Comp V4 wFlashing-Insert 422 SIMMONS RD 14.1 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S OROVILLE, CA 95966 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (47) TRINA SOLAR # TSM-300DD05A.18(II) SHEET: REV: DATE: . EQUIPMENT,WI THE WRITTEN PAGE NAME INVERTER: PERMISSION INC. Multiple Multi le Inverters THREE LINE DIAGRAM 6 0 11/14/2017 Pa ` Load Breaker CONFIDENTIAL — THE INFORMATION HEREIN 108 NUMBER: JB -9597588 00 CONTAINED MALL NOT BE USED FOR THE 40A/2P BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert PART TO OTHERS OUTSIDE THE RECIPIENTS 20A/1P ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE MODULES: (47) TRINA SOLAR # TSM-300DD05A.18(II TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PERMISSION OF TESLA INC. Multiple Inverters Pa ` Load Breaker Other 40A/2P Oven 40A/2P Other 60A/2P Air Conditioner 30A/2P Laundry, 20A/1P Bathroom 20A/1P Lighting Circuit 15A/lp • Lighting Circuit 15A/1P Lighting Circuit 15A/1P . Small Appliance 20A/11? Small Appliance 20A/11? ROSA MCCANN 422 SIMMONS RD OROVILLE, CA 95966 NEC 220.83 - Residential Load Calculation version 3.0 NEC 220.83(B) "Existing Dwelling Unit.... to determine if the existing service ... is of sufficient capacity ... The following percentages shall be used for existing ... loads ... First 8 kVA of load at 100%, Remainder of load at 40% NEC 220.83(B)(1) General lighting and general -use receptacles at ... 3 volt-amperes/ft? as determined by 220.12. Sq Ft VA Floor Area (3VA/sq ft) 1 -1800 •5400 NEC 220.83(8)(2) 1500 VA for each 2 -wire, 20 -ampere small -appliance branch circuit and each laundry branch circuit covered in 210.11(C)(1) and (C)(2). Small Appliance Circuits Qty VA Other 16 .24000 Laundry Circuits 1 1500 Other Bathroom Circuits 1 1500 NEC 220.83(B)(3) All appliances ... Ranges, wall -mounted ovens, counter -mounted cooking units ... Clothes dryers that are not connected to the laundry branch circuit .:. landl water heaters" Total General Load (non -A/C load) 59280 VA First 8 kVA of load at 100% I 8000 Remainder of load at 40% 20512 General Calculated Load (non -A/C load) 28512 VA NEC 220.83(8) The larger connected load of air-conditioning or space -heating, but not both, shall be used ... [at] 100 Percent of Load Breaker VA Other 40 7680 Oven 40 7680 Other 60 11520 Total General Load (non -A/C load) 59280 VA First 8 kVA of load at 100% I 8000 Remainder of load at 40% 20512 General Calculated Load (non -A/C load) 28512 VA NEC 220.83(8) The larger connected load of air-conditioning or space -heating, but not both, shall be used ... [at] 100 Percent of Load Max Heating and Air -Conditioning load 5640 VA Total Load Sum of General Calculated Load 34152 VA & Heating and A/C Load 142.3 A DESCRIPTION: OESGN: Rosa Mccann RESIDENCE Alonso Ortiz T = 5 L n 14.1 KW PV ARRAY PAGE NAME SHEET: REV: DAY-- ELECTRICAL AISELECTRICAL LOAD CALCULATIONS I oadCatosli/14/2017 Breaker I VA Sum of A/C Equipment Sum of Electric Furnaces 30 0 5640 0 Max Heating and Air -Conditioning load 5640 VA Total Load Sum of General Calculated Load 34152 VA & Heating and A/C Load 142.3 A DESCRIPTION: OESGN: Rosa Mccann RESIDENCE Alonso Ortiz T = 5 L n 14.1 KW PV ARRAY PAGE NAME SHEET: REV: DAY-- ELECTRICAL AISELECTRICAL LOAD CALCULATIONS I oadCatosli/14/2017 , - 5 '` s - • ' ' ' ' '� ',, Label Location: ' :. Label Location:- "'F � ..r i _ _ . ; . . � , M��`. ,' . ' • • - WARNING: (C)(IC)(CB) .. ..WARNING (DC)(CB), N `.WARNING y- a ; ` '- Per Code: " .' 'Per Code: r Per Code ` CEC 690.31.G.3--_ - - ■ • • • SHOCK HAZARD - CEC 690.17.E , • ' BY CEC 705 12 .D:2:c '. ' Label Location: • :• . ' SOURCES. RATING OVER CURRENT f %-, . Vit..` �''t' PHOTOVOLTAIC ' ••••ES MAY BE ENERGIZED (DC) (INV) •- -• • z, ,r•t D EXCLUDING MAIN - ' +, •'# ?- '; " ;~ *_ ' t• ",' ' DISCONNECT Per Code - • DEVICE SHALL • EXCEED AMPACITY h. ;, 0:13.CEC 69 • ' .. Label Location: Label Location: :.:'; PHOTOVOLTAIC POINT OF (POI) MAXIMUM POWER- (DC) (INV) INTERCONNECTION Per Code: y �- Label Location:- -• Per. Code:r;. -■ ■• • • G: ELECTRIC • CK CEC 690.54; CEC 690_:17 (DC)(INV)(CB)MAXIMUM t 4. ' - CEC 690.53,,. ' } TERMINALS • Per Code: •VOLTAGEPOWER- MAXIMUM SYSTEM BOTH THE LINE AND LOAD SIDE . ELECTRIC. . •- HAZARD• CEC 690.35(F) s- VOLTAGE► MAY BE ENERGIZED IN THE •- POSITION.FOR SERVICE PHOTOVOLTAICTO BE USED WHEN • - . BOTH SOURCE- • • ■ . INVERTER ISrAND ` ~, MAIN BREAKER. t rMAY BE ENERGIZEDUNGROUNDEDPV POWER SOURCE r MAXIMUM AC OPERATING CURRENT MAXIMUMAC Label Location: OPERATING VOLTAGE (INV)WARNING Per Code: - ELECTRIC IF AGROUND SH CK HAZARD •T IS INDICATED CEC 690.5(C) • - r t..; . NORMALLY GROUNDED Label'Location: CONDUCTORS MAY BE (INV) UNGROUNDED AND ENERGIZED PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID Per Code: 'SHUTDOWN CEC 690.56(C) Label Location: _` '. y - PHOTOVOLTAIC AC (AC) (POI) •. ' .. ' ° ' - -. ' �' .F ,,. -+ •-. � • " . • Per Code: Label Location: , CEC 690.13.B CAUTION (POI) . • + �,i . • -• • Per Code: SECOND SOURCE IS CEC 705.12.D.3PHOTOVOLTAIC _ SYSTEM Label Location: MAXIMUM •- •. (AC) (POI) _ •r :> _ _ " f ' .- I AC Per -Code:. "t y CEC 690.54• Label Location: _ • ;' r ; - v� OPERATING VOLTAGE '(POI)WARNING - Per Code:, OUTPUT CEC 705:2.D.2.b ti { rt • • • . ,' . • • • • . ^ i • _ (AC): AC'Disconnect Label Location: THIS OVERCURRENT }� (C): ConduitDEVICE PV SYSTEM (AC). s ..• •'. •(CB):.Combiner Box DISCONNECT ; a '_ • -A .t,. 4, L, (D). Distribution Panel`'Y' UTILITYf •. „ ' _ • '- + .(DC): DC Disconnect n ,, ,: ,• ;r. t"� , (IC): -Interior Run Conduit ' (INV): Inverter, With Integrated DC Disconnect (LC): Load Center ' v. z , , •L.` (M): Utility Meter (POI): Point of Interconnection ", ' ; : , . - "^ - � - , • Label Set - - - .. M -. . > - RAPID SHUTDOWN f - 1 • 1 r Rapid Shutdo'w'n Device for Delta 3.ON7.6-TL Inverters r - Delta's Rapid Shutdown Devices provide an automatic disconnect of 60OVDC - residential or small commericial PV array system, fully compliant with the Rapid • Shutdown requirements of NEC 2014 article 690.12. It is compatible with Delta's single-phase residential inverters.' + Y KEY FEATURES ' NEMA 4X Protection '� • Compact and Lightweight Rack Mount Installation _ • Fast Connect with PV Connectors ; t' • Compliant with NEC 2014 article 690.12 • PLC Communication (Model RSS-600 1-1 only) r COD ou S, • www.delta-americas.com An , .. _- n - � ' � . '!,' _- fit} - •, 4 Model RSS-60044 Connection Diagram: ---------------------a j. I - j - DELTA RAPID SHUTDOWN BOX I • - - -! �IAIAPATI�, ' - I �• ON ROOF WITHIN 10' OF PV 1 CH uS I I I---------- L — — — — — - -------- t------------- -- • I - ocPv. AC 'AC -------• ocvv- One conduit BREAKER GRID AC for all wiring Technical Specifications SV SIGNAL 14 • Input Ratings ! ! t . • • 600V DC 600V DC lam-.- . 1 4 20A 10A N/A 15A ' Output Ratings [Ma"z?Numbe,,6If, 0utput,CiFcuit 7.87 x 5.91 x 2.09(200 x 150 x 53) 12.44x10.04x2.16(316x255x55) [Rated Output CurrentPeiCgcud [Maximum,Current CTnnirolled'Condu`ctor LSuf-ut, ermi "' Y' 'rial;VVire,Size r r r • MC4 PV Connector or Amphenol H4 PV Conn ectorMC [O.utput'Conduit Slze SOMMMERMER nector or Amphenol H4 PV Connector [Con(rol Signal_Methc_ •. - .am •. 40 - 158°F (40 - 70°C) [SV�Signal�,reA1 6809 Rating • , • ill SV Si nal Wi e SIze,13 IMMM 0-100% } General Data , 7.87 x 5.91 x 2.09(200 x 150 x 53) 12.44x10.04x2.16(316x255x55) , 2.861bs (1.3kg)_ 6.61bs (3.0kg) j MC4 PV Connector or Amphenol H4 PV Conn ectorMC 4 PVConnector or Amphenol H4 PV Connector SOMMMERMER nector or Amphenol H4 PV Connector Screw Terminal Blocks •. - .am •. 40 - 158°F (40 - 70°C) 40 - 158°F (-40 - 70°C) • , • -40 - 185°F (4085°C) 40 - 185°F (-40 - 85°C) IMMM 0-100% 0-100% • . - . 2000m above sea level 2000m above sea level 10 Years 10 Years - Standard Compliance -. NEMA4X , NEMA4X UL 1741, CSA 22.2 107-1 NEC 2014 Article 690.12 - UL 1741, CSA 22.2 107-1 ; Article 690.12 NEC 2014 - y, _ _ - - Delta Products Corporation, Inc. Predu�a sp�iScoNans soA/nd:o c)t:w;lo ufPhnut rrcino. � .. 46101 Fremont Blvd. ' Fremont, CA 94538 'Sales Email: InvertecSales@delta corp.com Support Email: Inverter.Support@delta-corp.com t *• Sales Hotline: +1-877-440-5851 or .•1 - - •- r i +1-626-369-8021 r • ,y�7 ' , .. Support Hotline: +1-877-442-4832 Support (Intl.): +1-626-369-8019 - 1r •.• ' '" ' ' - r Monday to Friday from lam to Spm PST (apart from Holidays) . A� ��t IIEL wwwdelta-americas.com/solarinverters Ret 01r2017 -All iniontimon and spemcations area subject to change without notice '' •* " ja 4 y ♦ i r " + $OlarClty NO•0 f ;ti $OW01ty Delta Solar Inverters Datasheet for SolarCity • - y, INPUT (DC) ' ,,,� h t// •`? : r h•' ex. stem Volta a -- _ _ _ _ _ _ - —606-V Nominal Voltage _ 380 V i - 1 i r • [OperatingVol Range t15550 V- Full Power MPPT RanaeZ067566 V ., - C • ". „ - Wax Usable Usable Current 18.0 A 20 0 A= 20.O A per MPP tracker _ _ -ax. Shod Circuit Curenl a STC 25.0 A per MPP tracker • r - -` • ''ax, Allowable Imb bl Power - 4200 W 5000 W= L=5600 W • _ �I�DC Ratio 1.5 •'•+ .y . x r' DC Disconnect _ Internal I {{$. « * r • ` - -IVIPP Tracker 1 2 - ! J r . •krotal input Strings Available 2 4 OUTPUT (AC) r ominal Power �.�3000 W 3800 W 5200 W t_.�.__q6o0 W 600 W 3000 W-6-208 V I 3300 W @ 208 V / 5200 W j§_206 V / 6600 W ® 208 V I 6600 W (rb-208 V / .L-3000 W ® 240 V, 3800 W Q 240 V_jC 5200 W (d1 240 V _46600 W @ 24017600 W ®44o V�] 183-228 V/211-264V@240V ax. Contintious Power • olla .Ran a FN, -V@208 ' 14.4A(d 208V/ 158A®208V1 24.OA(d1208V/ 31.7 A'®208V/ 31.7A(d 208 V/ '�12,5A@240V�C15.8A@240V�L_21,6A(oj240V�L_27.5A®240V31.7 A(d1240 V_ .. 60 Hz ----lC---- ominal Frequen FraqlLeM_Ran_g_e_ _ _ _ _ —5s'i 7mg Hz d'ustable FLoquency Range _ _ _ _ _ _ _ _ 5n--66 0 Hz _ 91,-9— ht Consum n < 1.5 W olal Harmomc Distortion Nominal Power < 3114. ower Factor ft Nominal Power _ _ _ _ _ _ > 0.99 d'ustable Power Factor Range 0.85i 0.85c courtic Noise Emission t <50 db(Aj (� Im t 1 • S. , GENERAL SPECIFICATION ax, ffleny a y 98% # - ' •ICEC r • 7 • _ Efficiency rating Temperature RangeM 97.5%@ 208V 197 5 /_@ 240V F (•25-70 C) j direang above 1F 22 (50 C) ' 4 ' forage Temperature Range Ir -40= 1185*F (10 — 85•C) 0-100% a 1 - '" -' • umidi ax. O ereting Altitude _ - _ _ _ _ _ 2000m above sea level Aluminum _ q' MECHANICAL DESIGN • _ I STANDARDS-/ DIRECTIVES Lx Wx Dinches Lx Wx Dmm r 195 x 158 x8.5,n (495x401 x216 mm) �268x158x85in (680x401 z216 mm)"""""'j /: _ a. - nclosure Protection RatingNEMA - . ei ht - - 43.0 lbs (19.5 kg) 65 0 lbs (29 5 kg) ' - - [Cooling Natural Convection - - 3 • • .. ^' /1C Connectors Spnng temmnals in connection box ° Transformerless (TL): 3.8 kW, 5.2 kW, .6.6 kW, 7.6 kW • [Compatible WinnQ Gua a in AC_ _ AWG 12 AWG 6 Copper (According to NEC 310.15) - • `'• •• Connectors �:��,- =2, pans of spring terminals in connection bo� 4 pairs of spnng terminals in connection boz r) ' - .4'••. r om atible wirin Gua a In DC __-__- -- .. AWG 12 AWG 6 Copper (According to NEC 690.8) ' .+' *• _ CC pad 15 Class B - - r •` r, .. umca'on Interface •ZigBee , •- ,> I t a ' - is la 3 LEDs, 4 -Line LCD -Dieeasl a 1 t, • - •c closure Material Aluminum _ ,- • - f - _ _ , . - _ .}-- . - -• •_ T. .. _ _ _. _ _ • _ I STANDARDS-/ DIRECTIVES _ _ y - 4 .• nclosure Protection RatingNEMA 4X, IEC 60068-2 11 Salt mist - : -Solar In ve rte rs - - UL•1741 Second Etlition, CSA C22 2 No.107.1-01 - - 3 • • .. ^' royal UL 1998 ° Transformerless (TL): 3.8 kW, 5.2 kW, .6.6 kW, 7.6 kW • .: _ round -Fault Protection - NECs9o-35,UL;74.6_Ro - -' ' r • J 1 • ti-Islan In Protection IEEE 1547, IEEE 1547.1 • � � . * 2 .' .. z � � � - - ,- . • ' .+' _ CC pad 15 Class B . Wide Operating'Voltage Range: 85 — 550V ' + ' ' ' FCI�, UL 1899 B__ �),NEcse0.11 - •_ - _ r, ' w T 'v ' PV Rapid Shutdown UL 1741 CRD PVRSS NEC 690.12 (with SMART RSS) , Wide Operating Temperature Range: 713 '158'F (-25 -'70oC) .. + •` ;`� ', m ratedMetor ANSI C12.1 (meet =%Accura°y) t? Peculation of ndSu d CalfomaRule21,HECOCompliant,lEEE1547 High CEC Efficiency: 97.5% ^ '^ - • r' . - t WARRANTY Integrated AFCI (Arc Fault Circuit Interruption) x rwerowarren �_ ;oyeara t �_' • rte• - NEMA 4X plus Salt Mist Corrosion Protection Delta Products Corporation, Inc. , y Natural Convection Cooling- 48101 Fremont Blvd, Fremont. CA 94538 r , .,. • i ;. r y j# + . r 4 Sales Email: inverter.sales®deflaww.com .. ff 1 - :.Dual MPPT (5.2kW / 6.6kW / 7.6kw) • 1 ' r Support Emil: -+ 1-877440.58 1 or +1w26-36 Sales Hotline: +1.877.440.5851 or •1.828.389.8021 / Compact and Lightweight , • _ r ,_ Support Hotline: +l -877-442.4W2 Suppon (Intl.): +"26-369-8019.. •'} _ F ����� r,UL 1741 / IEEE 1547 / IEEE 1547.1 / CEC S� s Monday toF dayfrom7emto5pmPST(apanfomHolidays) rl • ' • r,. Listed /UL 1699B(Type 1) / NEC 690.11 - C IIS 4 . 4. Lf .. R •fes • . - ; ♦ . ,., I , ^ - • , - - W` t " '.�- �- •+' , f • I`'- ` ' JO Y ' 5018fClty ZepSolar. "` - � r , "Next -Level PV Mounting Technology ' $OI ity I ZepSolar Next -Level PV Mounting Technology '�, ' • s. •�, r ., �' •.l - ' ` •' . .. ' :f 1+ , F . - ..• t2 i•.'i �y k • A. ,i.P 1r' , Y - • � -' y' 4. Components ZS, Comp: for composition shingle roofs t+ •' ` * 1: , o L� ��� r \ �� Y i 3 .. s �1 ` ''� � � "'`yt^ r t n i� : ` i'C�r�{ ,.. ' s; • •�-, '•� rry t• �+, Rf1'. f�' 4. Mounting Block Array Skirt - Interlock Part No. 850-1633 Part No. 850-1608 or 500-0113 Part No. 850=1388 or 850-1613, Listed to UL 2703 Listed to UL 2703 Listed to UL 2703 x• `'. Flashing Insert Grip Ground Zep V2 Part No. 850-1628 Part No. 850-1606 or 850-1421 Part No. 850-1511' ' Listed to UL 2703 Listed to UL 2703 • Listed to UL 467 and UL 2703 •i GTi Q 6 P - - • � �Descri tion• ti PV mounting solution for composition shingle roofs t• t t A 0 Works with all Zep Compatible Modules °°iarar. Auto bonding UL -listed hardware creates structural and electrical bond . e + ZS Comp has a UL 1703 Class "A" Fire Rating when installed using modules from ' Y r ' r ' •,E- ' any manufacturer certified as "Type 1" or "Type 2" ., Captured Washer Lag End Cap « i DC Wire Clip LISTED " • Part No. 850-1631-001 Part No. Part No. 850-1509 " Specifications Y _ - t t 850-1631-002 (L) 850-1586 or 850-1460 Listed to UL 1565 " ' - " 850-1631-003 (R) 850-1588 or 850-1467 - ti Designed for pitched roofs t - 4 ' 850-1631-004 • d ` " Installs in portrait and landscape orientations ZS Comp supports module wind uplift and snow load pressures to 50 psf per UL 2703 } - Wind tunnel report to ASCE 7-05 and 7-10 standards _ r y, , • ' . - - t, • } • - - • ZS Comp grounding products are UL listed to UL 2703 and UL -467 • - - �t , ' - _ - �' - lis - *f • _ ' . ZS Comp bonding products are UL listed to UL 2703 - • Engineered for spans up to 72" and cantilevers up to 24" ' Zep wire management products listed to UL 1565 for wire positioning devices' Leveling Foot r� ; ;�, .fir • �: -. .. , "' ,, r; ' - � Part No. 850-1397 • .. Rn } ' zepsolar corn `. + • * zepsolar.com Listed to UL 2703 `►.0 . , ' t, .This document does not create any express warranty by Zep SolWor about its products or services. Zep Solar's sole warranty is contained in the written product warranty for - - . This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for - t each product. The end-user documentation shipped with Zap Solar's roducts constitutes the soles specifications referred to in the product warranty. The customer is solely each product. The end-user documentation shipped with Zap Solar's products constitutes the soles specifications referred to in the product warranty. The customer is solely ` , D PP P P. P P b� Y P PP P P P P Y Y • J responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. # : Document # 800-1839-001 Rev D :' " v Date last exported: April 29, 201611:22 AM Document # 800.1839-001 Rev 0e' ;xY "• '` ys: "` • i Date last exported: April 29, 201611:22 AM ^t "s 7 1 t ..- _ ..i s r - ' - . _, �; , r � • } T i .wf .N tit '~ � ` - -+ . J + - . Mono •Multi Solutions - •" -+ Trinamount FRAMED 60 -CELL MODULE. - PRODUCTS POWER RANGE f ELECTRICAL DATA (STC)- , THE 7 TSM-DD05A.18(Iq -...._. �ie 295 I 280-305W -• _.. -._..,.. • • _ a . a (• Peak Power Watts -P_ (Wp)- 275 _280 - 285 290 300 305 - - _1_ _ ll... _ _ Power Output Tolerance -P- (M 0- +5 .. r�na mou nt ' -7.DIMENSIONSOFPVMODULE(mminches) Maxim`mPowerVoltage-VmroM- -31.4- 31.7 31.8 32.2-' 32.5- 32.6 329 . �. a Maximum Power Current -l-' (A) 8.76 8.84 8.97 9.01 ' 9.08 9.19 9.28 MODULE' 60 CELL MONOCRYSTALLINE MODULE 275-305W l POWER OUTPUT RANGE .' •r n ys em e I Cates IEC61215/I EC61730/U Ll 703/IEC61701 /I EC62716 1509001: Quality Management System ISO 14001: Environmental Management System 15014064: Greenhouse gases Emissions Verification OHSAS 18001: Occupation Health and Safety Management System FZ°R`9'"" F(E 1 13 Ft S Trinasolar . i s 18.6% MAXIMUM EFFICIENCY ® N,m.gxe h AL J, B Monocrystalline 156.75 x 156.75 mm (6 inches) l _ ' 60 cells (6 x 10) 1650 x 992 x 40 mm (65.0 x 39.1 x 1.57 inches)• .-0Ar2 - - 4eu fipm4egsb4 12AN, No4 n ys em e I Cates IEC61215/I EC61730/U Ll 703/IEC61701 /I EC62716 1509001: Quality Management System ISO 14001: Environmental Management System 15014064: Greenhouse gases Emissions Verification OHSAS 18001: Occupation Health and Safety Management System FZ°R`9'"" F(E 1 13 Ft S Trinasolar . i s 18.6% MAXIMUM EFFICIENCY ® Maximize limited space with top -end efficiency • Up to 186 W/m2 power density - - Low thermal coefficients for greater energy production at high operating temperatures 40/157 992/39.1 Back View I, MECHANICAL DATA Solar Cells Cell Orientation - - - _ -.. Module Dimensions , Monocrystalline 156.75 x 156.75 mm (6 inches) l _ ' 60 cells (6 x 10) 1650 x 992 x 40 mm (65.0 x 39.1 x 1.57 inches)• - - Maximum System Voltage 1000V OC (IEC) Highly reliable due to stringent quality control 11/0.43 snuo0 s,w0t - _ Weight Open Circuit Voltage-Voc M 38.7 39.0 ,�` r 39.3 39.5 39.7 39.9 40.2 POSITIVE POWER TOLERANCE _ Short Circuit Current-Isc (A) y F444444 ------Module Efficiency 4(%) 9.26 16.8 - 8.35 17.1 White , 9.45 17.4 9.50 - - 17.7 9.55 18.0 ^9.64 18.3 ^9.72 18.6 ' - w Black Anodized Aluminium Alloy • STC Irradiance lODOW/m', Cell Temperature 25•C Air Mass AMIS. » 100% EL double inspection LINEAR PERFORMANCE WARRANTY j - - - --- - - . - - - - • parallel Wnnectlon) Measuring tolerance: ±391, $ I 1 -Box IP 65or IP 67 rated s '.. i 10 Year Product Warranty - 25 Year Linear Power Warranty- • Founded in 1997, Trina Solar is the world's leading ' ELECTRICAL DATA (NOCT) PACKAGING CONFIGURATION , • _ >, - comprehensive solutions provider for solar energy. we 35/138 Cables ' Maximum Power -P- (Wp) 205 209 Modules per box: 30 pieces - 212 216 220 223 7227Maximum �Mayximum Power Voltage -V -M 29.2 29A 29.6 29.9 30.2 30A 6- , Power Current-IAw (A) 7.02 1 I-V CURVES OF PV MODULE(305W) Connector 7,17 7.23 7.28 7.35 7.42 _ I Open Circuit Voltage-Va M 36.0 -7.10 36.3 36.6 36.7 36.9 ,S` 37.1 t 37.3 ! , _ 1 Short Circuit Current-Isc (A) 7.48 7.55 7.63 7.67 7.71 7.78 1 7.84 strategic, mutually beneficial collaboration with • 35 mm hail stones at 97 km/h iNOR: Irradiance at 800W/m'. Ambient Temperature 20-0 Wind Speed l m/s. a sa _ - i • • n ys em e I Cates IEC61215/I EC61730/U Ll 703/IEC61701 /I EC62716 1509001: Quality Management System ISO 14001: Environmental Management System 15014064: Greenhouse gases Emissions Verification OHSAS 18001: Occupation Health and Safety Management System FZ°R`9'"" F(E 1 13 Ft S Trinasolar . i s 18.6% MAXIMUM EFFICIENCY ® Maximize limited space with top -end efficiency • Up to 186 W/m2 power density - - Low thermal coefficients for greater energy production at high operating temperatures 40/157 992/39.1 Back View I, MECHANICAL DATA Solar Cells Cell Orientation - - - _ -.. Module Dimensions , Monocrystalline 156.75 x 156.75 mm (6 inches) l _ ' 60 cells (6 x 10) 1650 x 992 x 40 mm (65.0 x 39.1 x 1.57 inches)• - - Maximum System Voltage 1000V OC (IEC) Highly reliable due to stringent quality control 11/0.43 snuo0 s,w0t - _ Weight 19.6 kg (43.11b) y L 0 -..{.. 5 W ,�` r •Over 30 in-house tests (UV, TC, HF, and many more) , 1000V DC (UU I Glass 3.2 mm (0.13 inches), High Transmission, AR Coated Tempered Glass - POSITIVE POWER TOLERANCE _ In-house testing,goes well beyond certification requirements N Backsheet White , Max Series Fuse Rating 15A PID resistant$ 11I Frame - w Black Anodized Aluminium Alloy » 100% EL double inspection LINEAR PERFORMANCE WARRANTY j - - - --- - - . - - - - • parallel Wnnectlon) $ I 1 -Box IP 65or IP 67 rated s '.. i 10 Year Product Warranty - 25 Year Linear Power Warranty- • Founded in 1997, Trina Solar is the world's leading ' WARRANTY r PACKAGING CONFIGURATION , • _ >, - comprehensive solutions provider for solar energy. we 35/138 Cables Photovoltaic Technology Cable 4.Omm' (0.006 inches), f 2aow/ ----,-- _ on with our psits P iscriticalCertified to to Trina Solar distributes its PV Tina Solar Modules per box: 30 pieces - to withstand the most challenging ' g g ( 1000 (39.4 inches) - - - - success.ve success. now products to over 60 countries all over the world. Trina is able to environmental conditions (A -AJ Modules per 40' container. 840 pieces mm _ _ - provide exceptional service to each customer In each ml,,...•r...,.....,....»...,..,aa,.....,.�,. - I-V CURVES OF PV MODULE(305W) Connector MC4 1 market and supplement our innovative, reliable • 2400 Pa wind load + { ' rsn _ products with the backing of Trina as a strong, - ' • 5400 Pa snow load Fire Type UL 1703 Type 2 for Solar City-,Mrt•� - - - - - - bankable partner. We are committed to building en strategic, mutually beneficial collaboration with • 35 mm hail stones at 97 km/h installers, developers, distributors and other partners. i, a sa _ - i • • - - 10 2a �2opw ' I TEMPERATURE RATINGS• - - MAXIMUM RATINGS Comprehensive Products A AC t C rt'fi III •' �• "e 0 20 so 0 I NOCTw«mdnsloPeaungcellT-,a, v.e) 44"C(t2'C) OperationalTemperature�! a -40-+85°e n ys em e I Cates IEC61215/I EC61730/U Ll 703/IEC61701 /I EC62716 1509001: Quality Management System ISO 14001: Environmental Management System 15014064: Greenhouse gases Emissions Verification OHSAS 18001: Occupation Health and Safety Management System FZ°R`9'"" F(E 1 13 Ft S Trinasolar . i s 1 80% Years 5 10 is 20 25 ■ Trina Linear Warranty r3 Standard Step Warranty • Trinasolar CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. ® 2017 Trina Solar Limited. All rights reserved. Specifications Included In this datasheet are subject to change without notice. Version number. TSM_EN_2017_A t www.trinasolaccom - 1 Temperature Coefficient of P_ 0.39%%oC Maximum System Voltage 1000V OC (IEC) P -V CURVES OF PV MODULE(305M Temperature Coefficient of Vpc-029%)oc 1000V DC (UU _ Temperature Coefficient of Isc 0.05%/°C Max Series Fuse Rating 15A -�_J - �, - (DO NOT mnnea Fuse in Combiner 9o, with two or more wings in LINEAR PERFORMANCE WARRANTY 2W € 200 - _,oe„ ._. • parallel Wnnectlon) $ '.. i 10 Year Product Warranty - 25 Year Linear Power Warranty- • •��'/ ' WARRANTY r PACKAGING CONFIGURATION ` - ,0096 97% i T W. �^ 2aow/ ----,-- _ 10 year Product Workmanship Warranty Modules per box: 30 pieces - Ad T di BO nal y - - - - - value rr ( - • .. ; om Trina Sola/s *01 0 10 20 so ,a so 25 year Linear Power Warranty Modules per 40' container. 840 pieces 90% linea ',near anry veluga(W ml,,...•r...,.....,....»...,..,aa,.....,.�,. 1 80% Years 5 10 is 20 25 ■ Trina Linear Warranty r3 Standard Step Warranty • Trinasolar CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. ® 2017 Trina Solar Limited. All rights reserved. Specifications Included In this datasheet are subject to change without notice. Version number. TSM_EN_2017_A t www.trinasolaccom