Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
JB-9597588-00 (2)
ABBREVIATIONS • ELECTRICAL NOTES JURISDICTION- NOTES t A AMPERE' T. P,,C ALTERNATING CURRENT ' BLDG BUILDING ; - CONC CONCRETE DC DIRECT CURRENT EGC EQUIPMENT. GROUNDING CONDUCTOR , (E). EXISTING EMT ELECTRICAL METALLIC TUBING FSB FIRE SET—BACK GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR = GND GROUND HDG HOT DIPPED GALVANIZED . ? CURRENT ' Imp CURRENT AT MAX POWER Isc. SHORT CIRCUIT CURRENT kVA KILOVOLT AMPERE kW KILOWATT LBW LOAD . BEARING WALL MIN MINIMUM (N) NEW NEUT NEUTRAL NTS NOT TO SCALE OC ON CENTER PL PROPERTY. LINE Pal POINT OF INTERCONNECTION ' PV PHOTOVOLTAIC SCH 'SCHEDULE " S STAINLESS STEEL STC STANDARD TESTING CONDITIONS '. TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY } ` V - VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE -AT OPEN CIRCUIT W WATT 3R -NEMA 3R, RAINTIGHT ' - ` - Sheet 1 COVER SHEET Sheet 2 PROPERTY PLAN } Sheet 3 SITE PLAN Sheet 4 STRUCTURAL VIEWS LICENSE GENERAL NOTES Sneet 5 UPLIFT CALCULATIONS _ Sheet 6 THREE LINE DIAGRAM CA # 888104 1. ALL WORK TO BE DONE TO THE 2016 CALIFORNIA BUILDING CODE, 2016 CALIFORNIA Cutsheets Attached C-10 PLUMBING CODE, 2016 CALIFORNIA RESIDENTIAL ''l CODE, AND THE 2016 CALIFORNIA FIRE CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE AS AMENDED MODULE GROUNDING METHOD: ZEP SOLAR BY THE 2016 CALIFORNIA ELECTRIC CODE. 3. SMOKE AND CARBON MONOXIDE DETECTORS REV BY DATE COMMENTS AHJ: Butte County REQUIRED. REVA NAME DATE COMMENTS UTILITY: Pacific Gas'and Electric. Company CONFlDENRAL -THE INFORMATION HEREIN ,q8 NUMBER: JB CONTAINED SHALL NOT BE USED FOR THEROSA BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: -9597588 O O PREMISE OMER: MCCANN DESCRIPTION: Rosa Mccann RESIDENCE DESIGN: AIOnSO Ortiz T 5 L SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert _ 422 SIMMONS RD 14.1 KW PV ARRAY n PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES:OROVILLE CA 95966 ' TTHHE�SAILLEE AND USE F IN RRESPEcnVEwTM (47) TRINA SOLAR # TSM-300DD05A.18(II) APN: *� TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER' PAGE NAME: SHEET: REV DATE PERMISSION OF TESLA INC. Ie Inverters COVER SHEET .. 1 'a 11/14/2017 6'-8n M F • • e of l 't i` r t _ i, ' �7 l ... .• .4 �at _.-�•� •'�j f ` '`�'., .. .0 .} .r• - ( - `'� !!x'. L.tw •• � � w :.- - .' - f. y ef 22 10" • 4 x ' +• '' 7 \ _ • .yam r ♦ ... *• f +" r•' • S ; F' ' �` r .ay -• - Y - , •' . 46- 534 - 11 534-11\ 1 ' PROPERTY PLAN /' Scale:l" = 20'-0' ' .. \ . 134 -6� r 0 20' 40' 22 PREMISE OWNER: DESCRIPTION: , DESIGN: CONFIDENTIAL THE INFORMATION -HEREIN [INNVEIIRTER. NUMBER:,, JB -9597588 OO ; AIOnSO'OftIZ CONTAINED SHALL NOT BE USED FOR THEROSA MCCANN, Rosa Mccann RESIDENCE:. T �' S. L n BENEFIT OF ANYONE. EXCEPT TESLA INC.; NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN Comp V4 w Flashing -Insert 422 SIMMONS RD 14.1 KW PV -ARRAY - PART TO OTHERS OUTSIDE .THE RECIPIENT'S ` ORGANIZAnON,•EXCEPT IN CONNECTION wrni ULES OROVILLE, CA 95966 THE SALE AND USE OF THE RESPECTIVE 7) TRINA •SOLAR # TSM-300DD05A.18(II) , TESLA EQUIPMENT, .WITHOUT THE WRITTEN PAGE NAME SHEET REV:OATSPERMISSION OF TESLA INC. InvertersPROPERTY, PLAN 2 a 11/14/2017 PITCH 34 ARRAY PITCH 34 - _� „ •, _I MPl AZIMUTH:120 ARRAY AZIMUTH: 120 `• r' MATERIAL: Comp Shingle STORY: 1 Story PITCH: 34 ARRAY PITCH:34.' l • +; c�"j.. MP2 AZIMUTH: 300 ARRAY AZIMUTH:.300 . n-" * MATERIAL: Comp Shingle STORY: 1 Story ' t/ „i`, ' PITCH: 34 ARRAY PITCH: 34 sFron ouse Y , _ MP3 AZIMUTH: 300 ARRAY AZIMUTH: 300 4 ' y • l' _ MATERIAL: Comp Shingle STORY: 1 Story 7. rst7l� .9. LEGEND l M £d W �T� . �I N O W• 4_, ..11 I. • '.(E) UTILITY METER & WARNING LABEL , 0 I , If W i 3 F MP1 fi ZdW Inv on a_-_ _ --- --- N --- -- --� -- ,W Q DISTRIBUTION PANEL &, LABELS X1 1■� Lc LOAD CENTER &WARNING LABELS • ` 0 all I - ul --.— — — — — — — —,PS6---- --- J' WI • • • .i . Fl h� 1NVERTER W/ INTEGRATED OC DISCO . & WARNING 'LABELS ' © DC .DISCONNECT & WARNING LABELS TI - h© }- AC DISCONNECT & WARNING LABELS Q DC UNCTION COMBINER BOX & LABELS E—= L 3 F MP1 fi ZdW Inv /. _ --- --- N --- -- --� -- ,W Q DISTRIBUTION PANEL &, LABELS } I RSD IvTi 3_FSB Inv RSD — — — — — — — — — = O LC Lc LOAD CENTER &WARNING LABELS • ` 031 eIm O Q DEDICATED PV SYSTEM METER • '' I� RSD RAPID SHUTDOWN , * • -B I 'Q. LOCATIONS r. c0°n� LLI ' o •4' I —" ,STANDOFF CONDUIT RUN ON EXTERIOR i� Y .= --- -CONDUIT RUN ON INTERIOR ' ZS Comp V4 w Flashing–Insert - 1(47) 422 SIMMONS RD -GATE/FENCE -, SV " Q' HEAT PRODUCING VENTS ARE RED OROVILLE CA 95966 t. ' r� `` INTERIOR 'EQUIPMENT IS' DASHED MODULES . ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TRINA SOLAR # TSM-300DD05A',18(II), .. . • :. SITE • PLAN . 2 ScaIe:,1/8"'= 1' • R • '' 0 1' 8' 16' .. * CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE _t BENEFIT OF ANYONE EXCEPT TESLA INC., NOR JOB NUMBER: J B -;7-9597588,I t,- 0 0 PREMISE OWNER - ROSA MCCANN + DESCRIPTION: Rosa Mccann RESIDENCE - j DESIGN: Alonso Ortiz _ Y .= MOUNTING SYSTEM: - " SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing–Insert - 1(47) 422 SIMMONS RD , 14.1 KW, PV ARRAY n �' PART TO OTHERS OUTSIDE THE RECIPIENT'S OROVILLE CA 95966 t. ' IN MODULES . ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TRINA SOLAR # TSM-300DD05A',18(II), .. . l SHEET. REV: OATS71 31 0 11/14/2017 TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. • , PAGE NAME -I. SITE PLAN INVERTER: Multiple Inverters PV MODULE 5/16"X1.5" BOLT WITH' 5/16" FLAT WASHER INSTALLATION ORDER Sl ZEP LEVELING FOOT LOCATE RAFTER, MARK HOLE - ZEP ARRAY SKIRT. (1) LOCATION, AND DRILL PILOT ' ------ --——— — — — — —— HOLE. (N l P V MODULE ZEP MOUNTING BLOCK (4) ATTACH FLASHING INSERT. TO 1 'ZEP FLASHING INSERT (2) MOUNTING BLOCK AND ATTACH (3) TO RAFTER USING LAG SCREW. (E) COMP. SHINGLE INJECT SEALANT INTO FLASHING (E) MOUNTING PLANE (MP) (') INSERT PORT, WHICH SPREADS (E) ROOF DECKING (2) (3) SEALANT EVENLY OVER THE 5/16" DIA STAINLESS ' ' ROOF PENETRATION. ` STEEL LAG SCREW LOWEST MODULE SUBSEQUENT MODULES (2-1/2" EMBED, MIN)(4) INSTALL LEVELING FOOT ON TOP OF MOUNTING BLOCK & (E) RAFTER SECURELY FASTEN NTH BOLT. TYPICAL PV SIDE VIEW STANDOFF , Sv - NTS PV MODULE PV MODULE` 5/16"X1.5° BOLT WITH 5/16"X1.5 BOLT WITH 5/16" FLAT WASHER 5/,16" FLAT WASHER ' INSTALLATION r INSTALLATION ORDER ZEP LEVELING FOOT ZEP LEVELING FOOT LOCATE RAFTER, MARK HOLE LOCATE RAFTER, MARK HOLE r ZEP ARRAY SKIRT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT_ (1) LOCATION, AND DRILL PILOT, HOLE. HOLE. --— — — — — —— ---—— — — — — ——— — — — — —— — —————_— — — —— ZEP MOUNTING BLOCK ATTACH FLASHING INSERT TO ZEP MOUNTING BLOCK ATTACH FLASHING INSERT TO (4) (2) MOUNTING BLOCK AND ATTACH' (4) (2) MOUNTING BLOCK AND ATTACH, ZEP FLASHING INSERT (3) TO RAFTER USING LAG SCREW. ZEP FLASHING INSERT (3) TO RAFTER USING LAG SCREW. (E) COMP. SHINGLE (�) INJECT SEALANT INTO FLASHING (E) COMP. SHINGLE (1) - INJECT SEALANT INTO FLASHING INSERT PORT, WHICH SPREADS INSERT PORT, WHICH SPREADS (E) ROOF DECKING (2) (3) SEALANT EVENLY OVER THE (E) ROOF DECKING (2) (3) SEALANT EVENLY OVER THE �1<1ROOF PENETRATION. ., ROOF PENETRATION. 5/16 DIA STAINLESS LOWEST MODULE SUBSEQUENT MODULES 5/16 DIA STAINLESS LOWEST MODULE SUBSEQUENT MODULES STEEL LAG SCREW INSTALL LEVELING FOOT ON TOP STEEL LAG SCREW INSTALL LEVELING FOOT ON TOP (2-1/2 EMBED, MIN) [(4) OF MOUNTING BLOCK & (2-1/2" EMBED, MIN) OF MOUNTING BLOCK & (E) RAPIER SECURELY FASTEN WITH BOLT. t(E) RAPIER SECURELY FASTEN WITH BOLT. 1 STANDOFF ' STANDOFF CONFIDENTIAL -THE INFORMATION HERON JOB NUMBER: JB -9597588 O O PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE ROSA MCCANN Rosa Mccann RESIDENCE Alonso Ortiz T _. 5 L n BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSE) IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 422 SIMMONS RD 14.1, KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES OROVILLE CA 95966 ORGANIZATION, EXCEPT IN CONNECTION WITH i THE SAIF AND USE OF THE RESPECTIVE (47) TRINA SOLAR # TSM-30ODD05A.18(II) PACE Nave SHEET. REV DATE. EQUIPMENT, WITHOUT THE WRnTEN INVERTER: PERMISSION OF TESLA INC. Multiple Inverters STRUCTURAL VIEWS 4 a 11/14/2017 r i r ' DESIGN'SUMNIARY � ' • . y.. • ` •. f r� , !! • ' � " • N , � <. ... d' 3• . S w - 1 • .�. ,R • it �il ,' ' ' ' • '+� a - 1 z- tmporta`nceFadoc'1 • '. , `r.. _ .. , .. '(� T . .. . +. - 1't• ' �• r '• • � ' _� r Ground Snow: Load: � r, J: x . . , t, ' - MPS `ecific,Desi` n Information MP gains MP1 MP2. MP3 _ o Roofing 4. Com Roo! •p •. �:• �> Stand'off Comp;M6iiift SRV, :Comp MouritiSRV Com' p Modnt'SRV .. • - 4a, ..-a, � x.•44 .. 4, (. ,. '- •. .. ',_ StandoffsS acin .and La:.out 'MP Name MPI:. MP2': MP3 o. X Spacing X72'` 72" 72' a, 1 -Cantilever 24' ' 24> 24". -Y-Cantilever ' ,NA; NA- A" _,X-S046164 . ,, X S ....6ing Owl • X=Cantilever .. 20" 20" 20" Y=S . _clog . '84"' 84': , `64:,:: ,. n'.• Y Cantilever, ' NA, .. NA NA' Layout: „•. _.. . '',Not-Sta•`efed" Not-Sta eyed '• . Xand Y�aie''maximumsthatarealwa"s.relative;to tfie structure framin tfiat'su otts 1fie PV. 'X'is across:taftersraird:Y is alan rafters'.. r Y fl i r ,a ., - 'Y• L' . ! ' r [ , 1, :.„. ,'. :.4 � y -;, 1 . z "��. •..•• Y,k .y 9:, .. �S , _ - ' '~.�• . 1. _ r'r'w { , . } r v� .. +'• . � ♦ f i ` ,i a. _—, /. . , •�'~ , . a ,,�' ,f 'a•t 1• •?. , ±5r,r<r.F -i . i ±. � . as .. . ♦. ., r � ' , ` j.. # }° :.•� � - • � _ � ,,* .. � �' - .. , � �. ' - • - r i r ' DESIGN'SUMNIARY + 1114:2017'_ Version #71i ff Jo s59T a .. _ Jobs�teSpecific; Design iCElteria _ - .. .�.. .._.. a • �� ' - Design Code �. SHEET: REV DATE S 0 11/1.4/2017 . ASCE 7=10 :. z- tmporta`nceFadoc'1 4 1 d,• . a Ultimate Wind ;Speedl, Exposure Category= V-Uft . `•1'10 mph Rg .,1609A ASCETable 7=1 Ground Snow: Load: ' - MPS `ecific,Desi` n Information MP gains MP1 MP2. MP3 _ o Roofing 4. Com Roo! •p •. �:• �> Stand'off Comp;M6iiift SRV, :Comp MouritiSRV Com' p Modnt'SRV .. • - 4a, ..-a, � x.•44 .. 4, (. ,. '- •. .. ',_ StandoffsS acin .and La:.out 'MP Name MPI:. MP2': MP3 o. X Spacing X72'` 72" 72' a, 1 -Cantilever 24' ' 24> 24". -Y-Cantilever ' ,NA; NA- A" _,X-S046164 . ,, X S ....6ing Owl • X=Cantilever .. 20" 20" 20" Y=S . _clog . '84"' 84': , `64:,:: ,. n'.• Y Cantilever, ' NA, .. NA NA' Layout: „•. _.. . '',Not-Sta•`efed" Not-Sta eyed '• . Xand Y�aie''maximumsthatarealwa"s.relative;to tfie structure framin tfiat'su otts 1fie PV. 'X'is across:taftersraird:Y is alan rafters'.. Y fl r i r ' DESIGN'SUMNIARY + 1114:2017'_ Version #71i ff Jo s59T a .. _ Jobs�teSpecific; Design iCElteria _ - .. .�.. .._.. a • �� ' - Design Code �. SHEET: REV DATE S 0 11/1.4/2017 . ASCE 7=10 :. z- tmporta`nceFadoc'1 4 1 d,• . a Ultimate Wind ;Speedl, Exposure Category= V-Uft . `•1'10 mph Rg .,1609A ASCETable 7=1 Ground Snow: Load: ' - MPS `ecific,Desi` n Information MP gains MP1 MP2. MP3 _ o Roofing 4. Com Roo! '0,CompRoof4 CompRoot _ s �:• �> Stand'off Comp;M6iiift SRV, :Comp MouritiSRV Com' p Modnt'SRV - o,' SURLL: PV" SL1RLl c Nort, PV 16 O:W 16 0;prf 16 O psft -. - . StandoffsS acin .and La:.out 'MP Name MPI:. MP2': MP3 o. X Spacing X72'` 72" 72' a, 1 -Cantilever 24' ' 24> 24". -Y-Cantilever ' ,NA; NA- A" _,X-S046164 . ,, X S ....6ing Owl • X=Cantilever .. 20" 20" 20" Y=S . _clog . '84"' 84': , `64:,:: ,. n'.• Y Cantilever, ' NA, .. NA NA' Layout: „•. _.. . '',Not-Sta•`efed" Not-Sta eyed '• . Xand Y�aie''maximumsthatarealwa"s.relative;to tfie structure framin tfiat'su otts 1fie PV. 'X'is across:taftersraird:Y is alan rafters'.. r i r CONFIDENTIAL THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR, SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. Q QPREMISE JOB NUMBFR: J B— 9 5 9 7 5 U S '' ♦ 00", ' OWNER: DESCRIPTION: .� ' _ ROSA MCCANN `: Rosa Mccann" RESIDENCE' +422 SIMMONS RD �. '- •14.1 KW PV. ARRAY OROVILLE, 'CA 95966 J' +•. PAGE NAME 4 UPLIFT CALCULATIONS DESIGN: Alonso'Orti2 ' '• 1 =.• S L n' ' pr - - �. SHEET: REV DATE S 0 11/1.4/2017 . vu ... (Multi• le Inverters 4 CONFIDENTIAL THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR, SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF TESLA INC. Q QPREMISE JOB NUMBFR: J B— 9 5 9 7 5 U S '' ♦ 00", ' OWNER: DESCRIPTION: .� ' _ ROSA MCCANN `: Rosa Mccann" RESIDENCE' +422 SIMMONS RD �. '- •14.1 KW PV. ARRAY OROVILLE, 'CA 95966 J' +•. PAGE NAME 4 UPLIFT CALCULATIONS DESIGN: Alonso'Orti2 ' '• 1 =.• S L n' ' MOUNTING SYM. ZS Comp V4. w 'Flashing -Insert - MODULES - (47) TRINA SOLAR #-TSM-300DD05A.18(ll) r _ �. SHEET: REV DATE S 0 11/1.4/2017 . vu ... (Multi• le Inverters 4 GROUND SPECS _ MAIN PANEL SPECS GENERAL NOTES. INVERTER SPECS MODULE SPECS LICENSE OND (N) #6 GEC TO (E) UFER AT PANEL Panel-Number:TSM2020CFCU Meter Number. Inv 1: DC Ungrounded ;Inv 2: DC Ungrounded'. INV:1 '— (1)Delta g Bolivia 7.6 TL Inverter760ow, 24OV, 97.57, LABEL• A Zigbee, PLC — (47) TRINA SOLAR ##TSM-300DDOSA.18 II)) CA # 888104 C-10 WITH IRREVERSIBLE CRIMP 1007923655 .PV Module;30OW,270.6W PTCAOMM,B(k Frame,MC4,ZEP,1000V,Wht BckSht INV 2 Overhead Service Entrance Downsizing ' Main Breaker For Tie—In —{ 1)Delta #. Solivia 5.2 TL LABEL e Inverter,520OW, 24OV, 97.516, Zigbee, PLC Voc: 39.9 Vpmax: 32.6 INV 3 Isc. AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E 200A CENTER -FED MAIN SERVICE PANEL MULTI—CONTACT Delta N) 150A/2P MAIN CIRCUIT. BREAKER Inverter 1 IND Branch Socket BRYANT' . 7 I50A/2P 125A Load Center 10 Delta Dc+ Solivia.7.6 TL Da MPI: 1x10 T(N) (E) LOADS D 40A/2P EGC z��--------------------------------- -- 5 2 _ _ ----- - - - - -- ---- L2 DC+ DC+ 70A/2P ,: N EGG A DG 1 - 6 ° r — — — c. MPI: 1X9 r--, r 13)+ ---------------------------------- — — = ---. --- Dc+ T DG N G MP3: 1x9 1 a r , - 9 L -r. I = I `�-- ---- --- =------=-=--------- ------ ---=--GEC GND EGC------- - - - - -——----------- Gc ------------ -----� ----- - - - - - i.. ` ( I )Conduit Kit; 3/4' EMT Delta Inverter 2 IND N � 3 Delta LDG+ Bolivia 5.2` TL ' DG MP2: 1x9 30A 2P a zaov — — — — — — MULTI—CONTACT — — — _ ECG Branch Socket TD 1 TO 120/24OV - - L2 N ] 8 4SINGLE PHASE L EGC Dc+ — UTILITY SERVICE 1 ---- ----------------------------------- --- ---� N DC- MP1: 1x10 1 1 -----------—-----------—-------- GEC ------ GND EGG -- -- -- ---------------------- GC ---------- - - ---� - - ,- (1 )Conduit Kit:3/4'EMT--- Voc*' = MAX VOC AT MIN TEMP OTT (1)GE THQL2170 PV BACKFEED BREAKER 1 Breaker, 70A/2P, 2 Spaces (1)BRYANT g BR48LI25RP D Load Center 125A 120/240V, NEMA 3R AC R v (3)Delto $ Solivia Smart RSS Rapid Shutdown, 60OV, 20A, NEMA 4X, MC4 e (2)MULTI-CONTACT ! PV-AZB4 ^ Branch Socket; -MC4 U -Joint Connector, Female Female Male DC - (1 )GE THQP230' BREAKER Breaker, 3OA/2P, 1 Space - - (I)CUTLER-HAMM BR240. Breaker, 40A 2P, 2 aces (2)Delta p Bolivia y -(2)MULTI-CONTACT 9 PV-AZS4 Branch Plug; MC4 U -Joint Connector, Male Male Female g = (T) GE' / 1HQMV150WL MAIN BREAKER - (1) CUTLER-HAMM&R # BR230 Breaker 30A�2P, 2 Spaces v Smart RSS Rapid Shutdown, 60OV, 20A, NEMA 4x, MC4 t Circuit Breaker; 15OA/24OVP2� (2)AWG ./10, PV Wire, 60OV, Black Voc* = 396.71 VDC Isc = 9.64 ADC O IQF (1)AWG #10, THWN-2, Green EGC Vmp• = 293.4 VDC Imp= 9.19 ADC O (4)AWG /10, PV Wire, 60OV, Black Voc*' = 396.71 VDC 1.) AWG /10THWN-2, Green EGC Vmp = 293.4 VDC Isc - 19.28 ADC Imp= 18.38 ADC (2)AWG #10, PV wire, 60OV, Black O (I )AWG #10 THWN-2 Green EGC Voc* = 440.78VDC Isc = 9.64 ADC Vmp = 326 VDC Imp= 9.19 ADC (1)AWG #10, THWN-2 Black - (1) AWG ¢6, Solid Bare Copper GEC ©� (1)AWG $10; THWN-2, Red (I )AWG THWN-2, White NEUTRAL Vmp = 240 VAC Imp= 21.6 AA, .......L. 1) Conduit Kit: 3/4� EMT ' . e r (1)AWG $8, •T1tVM-2, Black - (1) AWG �6, Salic Bare Capper (1) AWG #8, THWN-2, Red ' ' GEC ........ O (1 Conduit Kit;_ 3/4' EMT.......... * 2 AWG 10, PV Wire, 60OV, Black Voc = 396.71 VDC ( � (1) AWG #10, THWN-2, Green • EGC Vmp = 293.4 VDC Isc - 19.28 ADC Imp= 18.38 ADC (1 Conduit Kit;. 3/4'_ EMT. ... - .• ������'''''' 4 AWG X10, PV Wire, 600V, Black 3 O I (1)AWG 810, THWN-2, Green EGC ..* ._ - Voc - 396.71 VDC Isc - 9.64 ADC Vmp = 293.4 VDC Imp= 9.19 ADC g10, (1) AN �8,. TFtWN-2,- Green • ,EGC . - . • -- (1)Conduit. Kit;. 3/4' ,EMT, . ' ' ' ' 'A - . .....:..70 (1) AWG ¢4, THWN-2, Black -(I)AWG #6, Solid Bare Copper GEC (1) AWG #10, THWN-2, White '- NEUTRAL Vm 240 VAC IMP=31.7 p p ) AWG �8,. TFtWN-2,. Greer ..EGC ....- (1) Conduit. Kit:. 3/4 .EMT.... AAC .... O - (1) Conduit Kit;. 3/4'. EMT- * 2 AWG 10, PV Wire, 60OV, Black Voc = 440.78VDC ( ) � . (1) AWG #10, THWN-2, Green EGC Vmp = 326 NDC - Isc = 9.64 ADC Imp= 9.19 ADC (1 Conduit' Kit • 3/4' EMT PV Wire 600V dr (2 WG g10, , Black 1) W (i) AWG #10, THWN-2, Green EGC * _ Voc VDC Isc - ADC - 396.71 - 9.64 Vmp = 293.4 VDC Imp= 9.19 ADC (1) AWG THWN- , RED _ (1 Conduit Kit:. 3/4'. EMT (1 Conduit Kit; 3 4' EMT ). /............ (1)A ! °RA41M, White NEUTRAL Vmp =240 VAC Imp= 53.3 AAC (1) EGC _ ® (2)AWG 110, PV Wire, 6a0V,•B1a k' Voc*=440.78VDC (1) AWG 110, THWN-2, Green. EGC Vmp = 326 VDC Isc =9.64 ADC Imp= 9.19 ADC �TT''(2)AWG #10, PV Wire, 60OV, Black ®I (1) AWG #10, THWN-2, EGC Vac*=440.78VDC Isc =9.64 ADC Vmp = 326. VDC Imp= 9.19 ADC - AN {i3 . TFtWN-2,_ Green - (1) CQNDUIT KIT ..... 1 x 10 EMT Conduit.......... _Green h.�LLN rAduit Kit: 3/4* FIAT CONFIDENTIAL THE INFORMATION HEREIN JOB NUMBER: J B-9 59 7588 0 0 PREMISE OVINER.- DESCRIPTION: DEIGN: CONTAINEDSHALLNOT BE USED FOR THE BENEFIT OF NOR ROSA MCCANN Rosa Mcconn RESIDENCE AIOnSO �ftlZ � � T � L �..� MouNTwG SYSTEM: SHALL �SCLOSED IN W OLLEE OR IN ZS Comp V4 wFlashing—Insert 422 SIMMONS RD 14.1 KW PV ARRAY �1�. PART TO OTHERS OUTSIDE THE RECIPIENTS OROVILLE, CA 95966 MDDULES ORGANIZATION, EXCEPT IN CONNECTION NTH THE SALE AND USE of THE RESPECTIVE (47) TRINA SOLAR'# TSM-300DD05A.18(II) SHEEL REV DATE TESLA EQUIPMENT, WITHOUT THE WRITTEN PACE NAME INVERTER: PERMISSION OF TELA INC. Multiple Inverters THREE LINE DIAGRAM 6 0 11/14/2017 Panel Schedule NEC 220.83 - Residential Load Calculation version 3.0 ELECTRICAL- CALCULATIONS' NEC 220.83(B) "Existing Dwelling Unit.... to determine if the existing service_. is of sufficient capacity ....The following percentages shall be used for existing... loads,... First 8 kVA of load at 100%, Remainder of load at 40% NEC 220:83(6)(1):- General lighting and general -use receptacles at..' 3 volt-amperes/ftp as determined by 220.12. Sq Ft I. VA J Floor Area ,(3VA/sq ft) 1800 5400 NEC 220.83(6)(2) 1500 VA for each 2 -wire, 20-ampere'small-appliance branch circuit and each laundry branch circuit covered in 210.11(C)(1) and (C)(2): Qty CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: JB -9597588 00 CONTAINED SHALL NOT BE USED FOR THE 24000 BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE ORAN ZS Comp V4 w Flashing -Insert PART TO OTHERS OUTSIDE THE RECIPIENTS 1500 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE MODULES: (47) TRINA SOLAR # TSM-300DD05A.18(II) TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PERMISSION OF TESLA INC. Multiple Inverters NEC 220.83(B) "Existing Dwelling Unit.... to determine if the existing service_. is of sufficient capacity ....The following percentages shall be used for existing... loads,... First 8 kVA of load at 100%, Remainder of load at 40% NEC 220:83(6)(1):- General lighting and general -use receptacles at..' 3 volt-amperes/ftp as determined by 220.12. Sq Ft I. VA J Floor Area ,(3VA/sq ft) 1800 5400 NEC 220.83(6)(2) 1500 VA for each 2 -wire, 20-ampere'small-appliance branch circuit and each laundry branch circuit covered in 210.11(C)(1) and (C)(2): NEC 220.83(B)(3). All appliances ... Ranges, wall -mounted ovens, counter -mounted cooking units ... Clothes dryers that are not connected to the laundry branch circuit ... [and] water heaters" Breaker. VA Other 40 7680 Oven Qty VA " Small Appliance Circuits 16 24000 Laundry Circuits 1 1500 Bathroom Circuits 1. 1500 NEC 220.83(B)(3). All appliances ... Ranges, wall -mounted ovens, counter -mounted cooking units ... Clothes dryers that are not connected to the laundry branch circuit ... [and] water heaters" Breaker. VA Other 40 7680 Oven Breaker 40 7680 30 0 Other 60 11520 Total General Load (non -A/C load) 59280 VA First 8 kVA of load at 100%..8000 8000 - Remainder of load at 40% 20512 General Calculated Load (non -A/C load) . 28512 VA NEC 220.83(8) The larger connected load of air-conditioning or space -heating, but not both, shall be used ... [at] 100 Percent of Load PREMISE OWNER: ROSA MCCANN 422 SIMMONS RD OROVILLE, CA 95966 Max Heating and Air -Conditioning load 5640 VA Tntal Lnad oum of General Calculated Load 34152 V Heating and A/C LoadIF 142.3 A DESCRIPTION: Rosa Mccann RESIDENCE • 14.1 KW PV ARRAY PAGE NAME ELECTRICAL LOAD CALCULATION DESIGN: Alonso Ortiz T 5 L n SHEET: REV: DATE oadCahcst 1 /14/2017 Breaker VA - Sum of A/C Equipment Sum of Electric Furnaces 30 0 5640 0 Max Heating and Air -Conditioning load 5640 VA Tntal Lnad oum of General Calculated Load 34152 V Heating and A/C LoadIF 142.3 A DESCRIPTION: Rosa Mccann RESIDENCE • 14.1 KW PV ARRAY PAGE NAME ELECTRICAL LOAD CALCULATION DESIGN: Alonso Ortiz T 5 L n SHEET: REV: DATE oadCahcst 1 /14/2017 f WP;�NING: PHOTOVOLTAIC POWER SOURCE Label o a o Per Code: CEC 69 e- .•0 Label Location:,,, w lei KO OLTAIC .DC DISCONNECTPer Code: call. Label Location: MAXIMUNI POWER -®A POINT CURRENT (Imp) MAXIMUM POWER- vCEC • • POINT VOLTAGE (Vmp)® MAXIMUNt SYSTEM�v VOLTAGE (Voc) SHORT-CIRCUIT® A CURRENT (Isc) Label• • WARNING INV ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED ' • NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED PHOTOVOLTAIC SYSTEP EQUIPPED WITH RAPIC SHUTDOWN PHOTOVOLTAIC AC ' • DISCONNECT •'" •'� CAUTION DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEI NIAXIMUM AC® A OPERATING CURRENT . NIAXIMUNI AC OPERATING VOLTAGE vCEC 690.54 Labele • PV SYSTEM µ. .� �` ai - � "•. p Label Location:` �„ � t • t , r * . 41 WARNING Per.Code: Per Code:' CEC 690.1.7.E THIS EQUIPMENT' BYCEC-705.12.D.2.cMULTIPL "► • > ��' E SOURCES. TOTAL RATING OF ALL OVER CURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. •Label � . • - t ..t r, .'- r - ''; -Location: _,•. ,.� _ • :�...-' .. -� .' a;. M • 'r r' r j (POI) ... i " s •, Per Code: Label Location: ' CEC 690.54; 'CEC 690.17WARNING (DC)(INV)(CB) r ` Per Code:�DE _ ELECT`THE ■ • . •- THIS • CK •'-. CEC 690.35(1=)PEN _,• '' , .•' PHOTOVOLTAIC.- OF - .TO BE USED WHEN -•. . . INVERTER•tSMAY - BE ENERGIZED UNGROUNDED, t �� ;• ' ¢' t j r `f;,. MA - ' • - : f . � � - ,; Y , •: Label"Location: •} ; .. �; , ', :." _ . , • '`' (INV) Per Code: CEC 690.56(C) Label Location: r: f• .y (POI) ... Per Code: < ` CEC 705.12.D.3 Label Location: - • , � <, i ,, .� � _ , � . (POI) - •�i + ;_ �: -Per Code: , CEC 705.12.D.2.b - ` �.(AC): ' AC Disconnect (C): Conduit " (CB): Combiner Box DISCONNECT• - • - • _ (D): Distribution Panel UTILITY(DC): DC Disconnect �. . (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect . (LC): Load Center , u (M): Utility Meter �• ' (POI): Point of Interconnection Label Set i 00 • t ` Msvt -. Iwo slH�nr�®INN •, - , Rapid Shutdown -Device- for Delta 3.0"7.6 TL Inverters Delta's Rapid Shutdown Devices provide an automatic disconnect of 6OOVDC residential or small commericial PV.array system, fully compliant with the Rapid Shutdown requirements of NEC 2014 article 690.12. It is compatible with Delta's single-phase residential inverters. KEY FEATURES " - NEMA 4X Protection • Compact and Lightweight • Rack Mount Installation ` • Fast Connect with PV Connectors • Compliant with NEC 2014 article 690.12 • PLC Communication (Model RSS-600 1-1 only) • C US - • www;delta-americas.com Model RSS-6004-2 Connection Diagram:________________________I I DELTA RAPID SHUTDOWN BOX I - i.•• �GII�PA�j I �ipi ON ROOF WITHIN 10' OF PV- �oFla ce ' ��w c us I � - I -------------- ;. DCPv. AC . AC _ BREAKER GRID •-------• Dc Pv • One conduit �- — •_ Ac for all wiring I I 1 Technical Specifications systc. J � Input Ratings , 0t • • • 600V DC 600V DC 1 4 a. • • 20A 10A N/A 15A Output Ratings l�lli General Data 7.87 x 5.91 x 2.09 ( 200 x 150 x 53) 12.44x10.04x2.16(316x255x55) 2.861bs (1.3kg) 6.6lbs (3.Okg) • MC 4 PV Connector orAmphenol H4 PV Connector MC -4 PV Connector orAmphenol H4 PV Connector • . MC -4 PV Connector orAmphenol H4 PV Connector Screw Terminal Blocks • . - . - . - . -40 - 158•F (40 - 70•C) -40 -158-F (40 - 70•C) IJ -40 - 185•F (40 - 85•C) 40 - 185°F (40 - 85•C) • 0-100% 0 -100x/. • . • 2000m above sea level 117 2000m above sea level 10 Years I 1 10 Years :9 Standard Compliance �. '• NEMA4X NEMA4X UL 1741, CSA 22.2 107-1 UL 1741, CSA 22.2 107-1 NEC 2014 Article 690.12 NEC 2014 Article 690.12. - - • • ?rc•�':r'spc¢/b YlN,l05 SUh/ad :0 Charf�0 rti.htl(r: RC'6'O. Delta Products Corporation, Inc. 46101 Fremont Blvd. . Fremont, CA 94538 Sales Email: Inverter.Sales@delta-corp.com Support Email: Inverter.Support@delta-corp.com Sales Hotline: +1-877-440-5851 or - +1-626-369-8021 Support Hotline: +1-877-442-4832 Support (Intl.): +1-626-369-8019 ' Monday to Friday from lam to Spm PST (apart from Holidays) www.delta-americas.com/solarinverters U WELa Rev. U7%_017 All Intnrmauon and speoticalions area sulied to change without notice - Delta Solar Inverters Datasheet for SolarCity INPUT (DC) ax. System Volta a 600 V Nominal Voltage 360 V 11 - ,�!' peralin Volta a Range _ 85'f 550 V , I , tulI Power MPPT Ra a -: _ 200 500 V ax. UsableCurtant 18.0 A� - 20.0 A� _ _ _ - 20.0 A per MPP Necker - + • v I - , - , ' Max. Short Circuit Current ® STC 25.0 A per MPP tracker • ,t " r _ I - _Max. Allowable Imbalance Power - 4200 W 5000 W 5600. W ° --- -1r 5d ., - lowed DC Loading Rat b 1.5 0C Disconnect =1 Internal , PP Tracker 1 2 olal Input StrisAvailable 2 4 ,,r° $: OUTPUT (AC) ' 1 a Nominal Prover -3000 W_.,3800 W I5.200 W 6600 W 7600 W ax. Continuous Power p00 WW @ 2 0 V� _3800W@240 PV/� 5 200 W �� 0 V 6600 2 0 V - 760 W 2040 V/ _ 183 - 228 V @ 208 V / 211 = 260 V (aj 240 V Voltage Range ominatCurrent rr 14.4A@208V!""� 15.BA�208V��40A�208V/ 31.7A®208V/ �31�7A(�208V/ 12.5A@R40V 158A@240V 216A@240V 27.SA@240V 31.7&@240V ominal Frequency _ _ 60 Hz _ Frequen Ran a'-� 59.3-60.5 Hz _ y djustable Frequency, Range _ 57.0 - 63.0 Hz • - I ht Consumption < 1.5 W i - otal Harmonic Distortion A Nominal Power -.3% Power Factor§ Nominal Paver 76.99 d'ustable Power Factor Rance i` _ _ _ _ _ _ _ 0.85i'0.85c _ co unlc Noise Emission ' GENERAL SPECIFICATION ' ., } ��__ • • - - ax. EfBden 98% )• t t. EC Efficiency 97.5% @ 208V / 97.5% @ 240V ..• yf' - �_. . ..�'" tin Tem ereture Ra e - -13 - 158°F (•25=70°C) 1 derating above 122°F (50°C)- torege Tempewture Range _ _ _ �.� d0- 185°F (-00 =85 r Humidity 0 - 100% n. - ... _ -Max. Opereting Altitude _ 2000m above sea level - t •r MECHANICAL DESIGN i, - ` • _ �• � • [Size L xWx DInches Lx Wz 0mm) �••'� 5_ i. n(4�95x-401x216-_mm)�q + 26.Sx 15.8x8.5 in(680x10x6 mm)= y ' , 4 �.• �r ^ eightI 43.016-1 (19.5 kg) _ '� y_ 65:6 lbs (29.5 -kg) [Cooling C Connectors Natural Convection Spring terminals in connection box • f _ y f ..--•� - 1 •.fit, , - ompatible Wiri Gua a in AC 10 15) - r AWG 12_ _AWG 6 Copper ( According to NEC 3110-15i-'- - - - - -Connectors 2 pairs of sprang terminals in connection box 4 pairs of sprang terminals in connection box ` ( - m tible Wiring Gua a in DC AWG12 - AWG 6 Copper (According to NEC 690.8) - - - ommunica8on Interlace S _ ZigBee [Display! 3 LEDs, 4 -Line LCD ' r - _ Enclosure Material ! _ DiecastAluminum STANDARDS / DIRECTIVES 'ndosure Solar I n ve rte rs'r ' Protection Ratio a ely NEMA 4X, IEC 60%8-2-11 Salt mist _ UL 1741 Second Edition, CSA C22.2 No.107 1-01y -7 Transformerless JQ: 3.8 kW, 5.2 kW, 6.6' kW, / .6 kW ' _fAntHslandIna W Approval round -Fault Protection Protection UL 1998 NEC 690.35,'UL 1741 CRD - IEEE 1547, IEEE 1547.1 _ • - .' Wide Operating Voltage Range: 85 - 550V • - - CF 1AFCI V Rapid Shutdown CC part 15 Class- UL 16998 (Type 1), NEC 690.11 Ul'1741 CRD PVRSS, NEC 690.12 (wish SMART RSS) - Wide Operating Temperature Range: -13 - 158°F (-25 - 70°C) ' •ulation m retedMeter _ ANSIC1211(meetl%Accuracy) _ _ _- _ ___ , High CEC Efficiency: 97.5% of Grid Support WARRANTY, California Rule 21, RECO Compliant, IEEE1547 - ' Integrated AFCI (Arc Fault Circuit Interruption) Integrated _ tandard Warranty- arranty _ _ _ _ - 10 years - - - ,- NEMA 4X plus Salt Mist Corrosion Protection Delta Products Corporation, Inc. • 46101 Fremont Blvd, - - - - Natural Convection Cooling Fremorant. C538 1 Sates Ainvertecsales@tle8aww.com t , Dual MPPT (5.2kW / 6.6kW / 7.6k" Support Support Email: inverter.support@deUaww.com Hotline: +1-877-440.5851 or +1-626-3638021 - Compact and Lightweight _ Support Hotline: +1-877-442-4832- Support (Intl.): +1-626-369-8019 AhELT LIL 1741 / IEEE 1547 / IEEEA 547.1 / CEC Monday toFriday fmm7am to5pm PST (spam from Hol days) Listed /UL 169913( Type 1) / NEC 690.11- C us • _ •t .I "A rY ', • ,% h,� 4, � • •� • r y - w•.-. , r - .! • y r, ' _ 9 •. � " ' * • .. , �4 y '~• • • ' ' l• .. •- , +t• ` -. ' •� • , . r , , J'� w }1� } "h` .0 s� .. - 9 ,F' J, _ •t ''Y �.aY .. '$OlafClt�/, ZepSOl2r `• Next-Level•PV Mounting Technology's Y ;;� ,�SolarCity " ZepSolarR +'4 Next -Level PV Mounting Technology' Components ZS Comp . 'for composition shingle roofs � ti � • ra,l, 14 fin. , • ,�: -� 4+ a � • y Mounting Block Array Skirt Interlock - ` Part No. 850-1633 Part No. 8501608 or 500-0113 > Part No. 8501388 or 8501613 Listed to UL 2703 F Listed to UL 2703 . Listed to UL 2703 s - - A Flashing Insert - f _ Grip y Ground Zep V2 . a Part No. 850-1628 Part No. 850-1 606 or 850-1421 Part No. 850-1511 ~ Listed to UL 2703 Listed to UL 2703 Listed to UL 467 and UL 2703 Description PV mounting solution for composition shingle roofs Works with all Zep Compatible Modules ' �Omppl Auto bonding UL -listed hardware creates structural and electrical bond _ • ZS Comp has a UL 1703 Class "A" Fire Rating when installed using modules from • r any manufacturer certified as "Type 1" or "Type 2" Captured Washer Lag End Cap DC Wire Clip , LISTED . t ' Part No. 850 Part No. - . Part No: 8501509 Specifications 850-1631-002 (L) 850-1586 or 850-1460 Listed to UL 1565 ' ` • 850431-003 (R) 850-1588 or 850-1467 ' ` a Designed for pitched roofs -8501631-004 .' 'Installs in portrait and landscape orientations { , . L ZS Comp"supports module wind uplift and snow load pressures to 50 psf per UL 2703 Wind tunnel report to ASCE 7-05 and 7-10 standards • ZS Comp, grounding products are UL listed to UL 2703 and UL 467 - r ZS Comp bonding products are UL listed to UL 2703 , Engineered for spans up to 72" and cantilevers up to 24" ' Zep wire management products listed to UL 1565 for.wire positioning devices • •, :• . ' - .. _ t1 .. - • .:. '; . , �• ' , ` .. �, .' ' Leveling Foot • • ? � � . - � • Part No. 850-1397 ` • • zepsolaccomzepsolaGcom + " Listed to UL 2703 ' { ...„ This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for .' • This document does'not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for _ 4 - each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred loin the product warranty. The customer is solely responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com.�, responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspals.com. , - - - Document # 800-1839-001 Rev D, �. , Date last exported: April 29, 2016 11:22 AM Document # 800-1839-001_ Rev 0 � ti Date last exported: April 29, 2016 11:22 AM ' . Mono Multi Solutions THE Trinamount MODULE, ,. .y .... a ..a.'. r 60 CELL -MONOCRYSTALLINE MODULE 275-305W a POWER OUTPUT�RANGE Maximize limited space with top -end efficiency ��0 ® • Up to 186 W/m2 power density 8.6 /0 ; Low thermal coefficients for greater energy production at high MAXIMUM EFFICIENCY 2 operating temperatures :HON+�, A; ^ Highly reliable due to stringent quality control V V SQ�� Over 30 in-house tests (UV, TC, HF, and many more) POSITIVE POWER TOLERANCE In-house testing goes well beyond certification requirements r ` PID resistant 100% EL double inspection ^ Founded in 1997, Trina Solar is the world's leading comprehensive solutions provider for solar energy. we believe close cooperation with our partners is critical Certified to withstand the most challenging - to success. Trina Solar now distributes its PV products r - toover 60countries allover the world. Trina is able to environmental conditions provide exceptional service to each customer in each market and supplement our innovative, reliable • 2400 Pa wind load _ _ products with the backing of Trina as a strong, bankable partner. Weare committed to building • 5400 Pa snow load • strategic, mutually beneficial collaboration with • 35 mm hail stones at 97 km/h installers, developers, distributors and other partners. Comprehensive Products. And System Certificates IEC61215AEC61730/ULl 703/IEC61701/IEC62716 .* 1509001: Quality Management System ISO 14001: Environmental Management System IS014064: Greenhouse gases Emissions Verification • OHSAS 18001: Occupation Health and Safety Management System I.2°1 F"- 7(c Trina -Oar LINEAR PERFORMANCE WARRANTY 10 Year Product Warranty • 25 Year Linear Power Warranty 100% �- 97%", Addfdo . nal value f , 3 90% rom 7^n. Sola rs linear warran Years 5 10 15 20 25 �• - 0 Trina Linear Warranty 13 Standard Step Warranty t •, Trinamount FRAMED 60 -CELL MODULE t. PRODUCTS POWER RANGE - y r • - 1 ELECTRICAL DATA (STC) 2 • •' TSM-DD05A 181jn I 280-305W DIMENSIONS OF PV MODULE(mm/inches) r .. WIATD i � - r Trinamount FRAMED 60 -CELL MODULE t. PRODUCTS POWER RANGE - y r • - 1 ELECTRICAL DATA (STC) 2 • •' TSM-DD05A 181jn I 280-305W DIMENSIONS OF PV MODULE(mm/inches) r .. WIATD 40/157 992/39.1 • t Back View 11/0.43 Slllwnseabnt - • - LamWa 35/138 (A -A) ,v I-V CURVES OF PV MODULE(305W) ^ 1 r9.=Q9awAa' en - ao9w 2A - a m so - v so :D napw/ar IA 0 20: so M SO vdageM - 4 - P-VCURVESOF PVMODULE(305M -. 330 toowvmJ aao - " Tso _eomv/m_ - $Iso so - a r to to w .o so voltageM r, Peak Power Watts-PNAx Mp)• Nam.pae 8 Power Output. Tolerance -Z jN4- AL g. JA e III - 31.4 , 31.7 w9,n a omn9 Ia. 32.2 32.5 txa.m lsdr _ s 32.9 40/157 992/39.1 • t Back View 11/0.43 Slllwnseabnt - • - LamWa 35/138 (A -A) ,v I-V CURVES OF PV MODULE(305W) ^ 1 r9.=Q9awAa' en - ao9w 2A - a m so - v so :D napw/ar IA 0 20: so M SO vdageM - 4 - P-VCURVESOF PVMODULE(305M -. 330 toowvmJ aao - " Tso _eomv/m_ - $Iso so - a r to to w .o so voltageM r, Peak Power Watts-PNAx Mp)• 275 280 I 285 ' I 290 I 295 300 .. 305 Power Output. Tolerance -Z jN4- - .' 0-+5P ' Maximum Power Voltage -V -M 31.4 , 31.7 31.8 32.2 32.5 132.6 32.9 Maximum Power Curtent-laPr (A) 8.76 r. r 8.84 • - 8.97 9.01. 9.08 9.19 36.0 363 Open Circuit Voltage-Voc M 38.7 39.0 •' 39.3 39.5 39.7 7 39.9 40.2 Short Circut Current-Isc (A) 9.26 - 9� 35 9.45 9.50 :q 9.55 9.64 9.72 Module Efficiency ra (%) 16.8 17.1 17.4 •- 17.7 18.0 18.3 18.6 f STC Irradiance 1000W/m', Cell Temperature 2s•C Air Mass AMIS. 'Measuring tolerance: 1391, h. ELECTRICAL DATA (NOCT) .. - Maximum Power-Paux (Wp)..205 209 '_ 212 216 220. 223 22 Maximum Power Voltage -V -M 29.2 29.4 - 29.6 :29.9 30.2 •30.4 30. Maximum Power Current -l- (A) 7.02 7.10 7.17 7.23 7.28 735 7.42 ' Open Circuit Voltage-Vcc M 36.0 363 36.6 36.7 36.9 Short Circuit Current -1. 7.48 7.55 7.63 - 7.67 7.71 7.78 7.84 NOR: Irradiance at SWW/m', Amblent Temperature 20C Wind speed lm/s. MECHANICAL DATA Solar Cells Monocrystalline 156.75 x 156.75 mm (6 inches) - Cell Orientation - 6Ocells(6x10)".- -• 4 � Module Dimensions - 1650x 992 x 40 mm (65.0 x 39.1 x 157 inches) ,Weight ` '•.19.6 kg (43.11b) . Glass ' - 3.2 mm (0.13 inches), High Transmission, AR Coated Tempered Glass Temperature Coefficient of P- Backsheet Temperature Coefficient of Vdc White lit Temperature Coefficient of 1% { Frame - Black Anodized Aluminium Alloy 1 -Box, IP 65 or IP 67 rated Cables • Photovoltaic Technology Cable 4.0mm2(0.006 inches), - 1000 mm (39.4 Inches) Connector ! MC4 t Fire Type _ _ _ UL 1703 Type 2 for Solar City • r e + TEMPERATURE RATINGS MAXIMUM RATINGS NOCT(Nomlral Operatl, Cell Tempwature) . 44°C(t2°Q Temperature Coefficient of P- _ 03996/°C' _ Temperature Coefficient of Vdc --0.2996PC Temperature Coefficient of 1% Operational Temperature -40-+85°C Maximum System Voltage 1000V DC (IEC) .. ° 1000V DC (UU . Max Series Fuse Rating ' .. 15A r ' (00 NOT connect Fuse In Combiner aux with two or more strings In , ,r 1 parallelconnettlon) 4 WARRANTY PACKAGING CONFIGURATION 10 year Product Workmanship Warranty r Modulesperbox:31 pieces - 25 year Linear Power Warranty - Modules per 40' container. 840 pieces (Please refer to product warranty for details) t - 1 A CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. ' Trina'solar02017 Trina Solar Limited. All rights reserved. Specifications Included In this datasheet are subject to change without notice. Versionnurnber TSM -EN 2017-A - wwwArinasolar.com