HomeMy WebLinkAboutJOHN FAGUNDESArray:
y
Modules: (22) SolarWorld SW275 Mono Black 275W Modules
Inverters: (22) Enphase Energy M250 240W AC Microinverters
t
Mounting Method: Flush Mounted. - (22) modules
Ironridge roof mount system with XRP
Array Azimuth: (22) Modules at 180°
A: (Existing) All -in -one utility meter and main service panel, 200A,
120/240V, '10
B: (1) (New) PVC SCH. 40 conduit run (±125 ft run) (Buried 18"
below grade
C: (1) (Existing) Shop Sub -Panel; 200A 120/240V
D: (1) (New) PV system dedicated 125A, AC aggregate panel -
(2) Back -fed circuit breakers
E: (1) Wire runs
F: (2) (New) PV system junction box (UL 1741, NEMA 3R)
(Located behind modules)
P'V System Equipment Wall (Plan View)
Equipment Wall - Equipment WallArray
(Adjacent to utility meter) (At garage) (On Roof)
-- -- I -- I --- —I---
A B C D E F
t OWNER / JOB SITE
Mr. John Fagundes
10 Hawk Pl.,
Chico, CA 95973
APN: 047-460-035
CONTRACTOR
North State Solar Energy
PO Box 899
Forest Ranch, CA 95942
Lic. 813508
y
PROJECT DETAILS
New 6KW solar PV roof mount
r array using microniverters on Iron
Ridge racking system tied into
existing load center. All wiring is
AC.
Page 2
Page Details:
Single Line Diagram for
Mr. & Mrs. Fagundes
Project Details:
New 6KW Roof Mount PV Array
using microinverters on Iron
Ridge mounting system going to
main residence.
(Existing)
Utility Meter
120/240V
0
Meter Panel
200A
30A
Breaker
(22) 240 WATT Utility Interactive Inverters
Enphase M250 -60-240-S22
CEC Model: Enphase M250-60-2LL-S2x (-ZC)(-NA)(240V)
CEC-Inverter Efficiency: 96.5%
240VAC, 10, 6011z
Voltage and Phase Sensing Neutral
i Listed to UL 1741
48 VDC Max Input Voltage
Integrated G.E.C. Ground
PV Circut:
(11) SolarWorld SW275 Mono Black Module Module Module
275W Modules , , , Junction Box
Microinverter Microinverter Microinverter NEMA 3R, UL 1741
(At Array)
PV Circut: —
(11) SolarWorld SW275 Mono Black Module Module Module
275W Modules
Microinverter Microinverter Microinverter
240 VAC
(Existing) (±125 ft run)
2 - #2 THWN-2 CU
1 - #2 THWN-2 CU Neutral
1 - #6 THWN-2 CU E.G.C.
(GND TO BE CONTINUOUS)
1.25" PVC SCH 40 Conduit
(Buried 18" Below Grade)
Enphase AC
Engage Cable
And Bare #6 AWG
E.G.C. Ground
(Existing)
Shop Sub -Panel
120/240V; 200A
30A
2 - #8 AWG THWN-2 CU
1 - #8 AWG THWN-2 CU Neutral
1 -#8 AWG THWN-2 CU E.G.C.
(Gnd to be continuous)
V LFMC Conduit
20A
240 VAC (f15 FT RUN)
4 - # 12 AWG THWN-2 CU
1 - # 12 AWG THWN-2 CU Neutral
1 - #8 AWG THWN-2 CU E.G.C.
(Gnd to be continuous)
3/4" LFMC Conduit
(Run behind array)
Dedicated PV System
AC Aggregate Panel
120/240 VAC, 125 AMP, NEMA 3R
Main Lug Only
(2) 2P -20A PV Circut Breakers
(Located at array)