HomeMy WebLinkAboutTRACY SCHOHR'V Array: , ti. Modules: (28) SolarWorld SW285 Mono 285W Modules Inverters: (28) Enphase Energy M250 240W AC Microinverters t . Mounting Method: Flush Mounted. - (28) modules Ironridge roof mount system,with XR100 rail t: Array Azimuth: (28) Modules at 1801 4 -o t PV System Equipment Wall (Plan View) ' Equipment Wall Equipment Wall ` may (Adjacent to utility meter) (At garage) (on Roof) ilk I C D E A: (Existing) All -in -one utility meter and main service panel, 200A, 120/240V, is B: (1) (New) PVC SCH. 40 conduit run (f60 ft run) (Buried 18" below grade C: (New) PV system dedicated 125A, AC aggregate panel (2) back -fed circuit breakers D: (1) Wire runs E: (2) (New) PV system junction box (UL 174 1,, NEMA 3R) (Located behind modules) r � ' I OWNER / JOB SITE Ms. Tracy Schohr 1474 Bonnell Ave, Gridley, CA 95948 APN: 024-260-083 CONTRACTOR North State Solar Energy PO Box 899 Forest Ranch, CA 95942 Lic. #813508 PROJECT DETAILS New 7KW solar PV roof mount array using microinverters on Iron Ridge racking system tied into existing load center. All wiring is AC. .J a� d' t t r � ' I OWNER / JOB SITE Ms. Tracy Schohr 1474 Bonnell Ave, Gridley, CA 95948 APN: 024-260-083 CONTRACTOR North State Solar Energy PO Box 899 Forest Ranch, CA 95942 Lic. #813508 PROJECT DETAILS New 7KW solar PV roof mount array using microinverters on Iron Ridge racking system tied into existing load center. All wiring is AC. . t r � ' I OWNER / JOB SITE Ms. Tracy Schohr 1474 Bonnell Ave, Gridley, CA 95948 APN: 024-260-083 CONTRACTOR North State Solar Energy PO Box 899 Forest Ranch, CA 95942 Lic. #813508 PROJECT DETAILS New 7KW solar PV roof mount array using microinverters on Iron Ridge racking system tied into existing load center. All wiring is AC. (Existing) Utility Meter 8 200A 40A Circut Breaker (28) 240 WATT Utility Interactive Inverters Enphase M250 -60-240-S22 CEC Model: Enphase M25,0-60-2LL-S2x (-ZC)(-NA)(240V) CEC-Inverter EfficiencY,%0.5% 240VAC, I$,'6OHz Voltage and Phase Sensing Neutral g g.. Listed to UL 1741 _ - 48 VDC Max Input Voltage Integrated G.E.C. Ground j PV Circut: (14) SolarWorld SW285 Mono Module Module Module 285W Modules Junction Box Microinverter;, Microinverter; Microinverter NEMA 3R, UL 1741 (At Array) PV Circut: r. (14) SolarWorld.SW285 Mono Module Module Module 4 285W Modules Microinverter Microinverter Microinverter ti " 240 VAC (±10 FT RUN) i' 4 - #12 AWG THWN-2 CU I; 1 - # 12 AWG THWN-2 CU (N) 1 - #8 AWG THWN-2 CU E.G.C. 240 VAC 1" (Gnd to be continuous) ` Enphase AC �f, 1" LFMC Conduit (f60 ft run) _ Engage Cable (Run behind array) 2 - #4 THHN CU And Bare #6 AWG 1 - #4 THHN CU Neutral E.G.C. Ground 1 - #8 THHN CU E.G.C. (GND TO BE CONTINUOUS) 1.25" PVC SCHAO Conduit (Buried 18" Below Grade)