Loading...
HomeMy WebLinkAboutTRUSS CALC SUBMITTAL"Serving The Best Builders' yS"y,•r �, 4011 Sierra College Blvd., Loomis, CA 95650 Phone (916) 652-4655 Fax (916) 652-3860 5033 Feather River Blvd., Olivehurst, CA 95961 Phone (530) 743-8855 Fax (530) 743-8856 WWW C72OMFWOOD COM Client: Lewis Williams Promect: Single Family Residence 1779 South valla Ave WET SEAL Palermo, Ca Truss Designer: Tracking / Work Order # Bryan Wagner 0220316 brva nw(c-0 homewoodtruss.com Phone: (530) 743-8855 ry triai version www.paTTactorV.com PH (530) 743-8855 S=NIL=El AM=LY RES=DF— Fax (530)743-8856 L 1—:;"w I S W= L L= AM S 1 7? 9 SOUTH V=LLA AVE HOMEWOOD TRUS S CO ,�\/I �\✓\/ P A L E RM O C A 9 5 9 6 8 5033 FEATHER aTVER BLVD 0,T-TVEHUaST, CA, 95901 C -I'2 1-� 2-f"�lOf1��f� �C bi�Cb-Pri 4)M 1 SALES REP: BW WO#: 0220316 DUE DATE: 03/09/16 C71 i i I r� 1`lw+ �j r e DSGNR/CHKR: AW /'BW Date: S/6/2016 13:SS 4 DurFac-1,]=)r 1.2S TC Dead 14.00 psf DurFac-Plt 1.2S v BC Live 0.00 psf ii n BC Dead 8.00 psP Design Spec: CRC -2013 u ii � u v ii #Tr/#Cfg: 9S / 20 GOG SALES REP: BW WO#: 0220316 DUE DATE: 03/09/16 SCALE: 1"=9' 0" DSGNR/CHKR: AW /'BW Date: S/6/2016 13:SS TC Live 20.00 psP DurFac-1,]=)r 1.2S TC Dead 14.00 psf DurFac-Plt 1.2S BC Live 0.00 psf O -C. Spacing: 2 BC Dead 8.00 psP Design Spec: CRC -2013 #Tr/#Cfg: 9S / 20 Total 42.00 psf a Job Name: SINGLE FAMILY RESIDENCE Truss ID: A01 Qty: 2 RRC %- IOC RHACI' SIZE REQ'D 7C 2z4 DFL 81 i Rtr. Wei hracing regmired at each location shown. ® This design based on chord bracing applied 1 0- 1-12 978 3.50" 1.50" 2 17-10- 4 2280 3.50" 2.43" RC 2a4 DFL 81 i ttr. Refer to WCSI for proper required lateral WEN 2:4 DFL STANDARD restraint. For alteroative web bracing, per the following schedule: ,.. man o.c- fro■ to 3 38- 8- 4 1764 3.50" 1.88 Designed per ANSI/TPI 1-2007 see rMCG's standard details. TC 24.00" 10- 5- 4 28- 4-12 4 46-11-12 357 3.50" 1. s0" BAZ DEFLECTION Bearings designed for an FcPerp value of the Fabrication Tolerance = 20.0% UPLIFT REACTION(S) : (span) : L/861 HIDE 15-16 (LIVE) LC 40 lesser of the truss chord lumber value or Ker (creep factor) = 2.00 825 for hearings. Refer to Joint QC Detail Sheets for Support CK Wind Non -Wind t lb L= -0.29". D= "0.27" T= -0.57" all 1RC/I1C truss plate values arc based on Cq factors and Rotational Tolerances. -88 2 -42 lb _= J•iat satin m 1 0- 0- 0 10 47. 1- 8 testing and approval as required by IBC 1703 Loaded for 10 PSF moa-rnncarrent ROLL. 9 -113 16 3 7- a- a 11 e- o- o and AN and wine reported in BTR -1118. Bari all interior bearing locations. Drai a shall be rovided to avoid ndi Install Interior savpGport(s) before erection. rob ag- 4 -60 lb HORIZONTAL RRACTION(S) a lo- 5. 4 12 7- a- 0 P PO This truss is designed using the PLAYING BASED ON 6 IEEN LUI®� VALOTS. a rt 1 "235 lb appo 4 17.10.4 13 te- 5- 4 5 24• l -1L a t7ao• 4 s ie- 4.1z 15 24- 1-13 ASCE?-10 Wind Specification 20 Fief Live Load wpplied to bottom chord is Bldg Reclosed IRC/IRC sopport 4 -235 Ib 7 33- s- 7 16 33• S- 7 6 38- 8- 4 17 38- 8- 4 =Yea, accordance with code provisions. irmss Locallom Not End Rax 9 40- B• 4' le 47- 1. 8Esip Category = C RITICILL 1®un FORM. e b = 65.08 ft, Bldg Width = 72.33 ft BldgLear TC COIR. Out. / TENS.[like. Ciel 1-2on 1.0 / 118.600.50 Bean roof height = 14.54 ft, ■ph = I10 E-3 "613 1.25 / 313.600.36 Occupancy Category II, Dead Load = 13.2 psf Desi Baia ®Ind Force Resists S 3-4 -86 1.60 / let.80is SO 1.21/lee.600.45 as stem B�� ag y4.3•466 - taw -rise and Components and Cladding 3-6 -469 1.115 / 168.60O.al 6-1098 .15248.60 O.187-8 Tributary Area = 94 sqft -812 1.25 / 75.60.33 8-9 •66 1.60 / 462.2s0.459-10 -140 1.25 / LSE.15 0.43 .PSI11-1L It COUP. 0. / 7P1L5.1111-711-11 40((01.603/64-9S0.3811.13 -40(1.60)/ 646. 0.3713.14 / 405. 0.34 14-15-lE9 1.60 10150.3815.16 .41.80 / 505. 0.55 16.17 •3801 1.015 / 109. 0.37 17-t6 -1107 I.ES / 90. 0.34 IN EYP. OUR. TINS. DU1. CSI a_la / als 1.25 0.11 10-5-4 17-11-8 5-0-11 13-8-1 sls LES / 169 1.69 0.43 L -I3 10'..' I I I 1 2 3 4 5 6 7 8 9 10 3a3 -101 1.so / 677 l.zs o.L7 334 -934 1.620 / 77 1.25 o.49 4-U -1326 I.25 / /o0 1.60 0.49 10.00 -10.0 -4.O 4•ls -31 1.eo / 974 1.2s D.4o 3-15 -376 l.zs / 81 1.60 0.14 ' 4X10 6-15 -1t2 1.25 / 49 1.60 0.05 6.16 "130 1.60 / 490 1.23 o.L4 5X8 4X4 1.5X4 Tae au 1.23 / 31a 1.60 o.zs 8-16-17 1.60 / 1274 1.23 0.5E T 817 -lEE6 1.115 / 1424 1.60 0.30 9..17 -413 1.z5 / 93l1.601 0.07 3X6 5X6 1.5X4 9 i , 4X4 9-11-15 . SHIP 3X6 3X6 1 x x 0-4-11 1.5X4 4X8 6X8 3X4 5X6 0-3-13 s,�E$GI _ B1 3X4 B2 B3 B4 W:308 W:308 W-308 W:308 -T. TiQN 4t�, 17-104 38-8 4 R:978R:2280 R:1764 R:357 J U:-88' U:42 U:-113 U:-60 _ 1�,00 _ 11.0,0 47-1-8 11 12 13 14 15 16 17 18 No. C 72160 OVER 4 SUPPORTS CNi\. P All Connector plates are ALPINE Wave 20 ga., unless preceded by "H• for High Strength 20 ga., "S" far Super - Strength 18 ga. Plates are to be positioned per Joint Detail Report. Circledrates and false frame plates Shift - 5/6/2016 are positioned as shown above. gable stud plates to avoid overlap with structural plates. ;. 26S - Homewoodruss "`WARNING!"" READ AND FOLLOW ALL NOTES ON THIS DRAWING! Cust: LEWIS WILLIAMS (TCA) "IMPORTANT" FURNISH THIS DRA WING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. DIB: Brive_M_0220316_L00007-J00001 Trusses require altreme care in fabricating, handing, shipping, installing and bracing. Refer to and follow the latest edition of SCSI (Builfing Component W0: Drive_M_O220318_L000 Safety Information, by TPI and WTCA) for safety practices prior to performing these functions. Instaners shall provide temporary bracing per BCSL unless Dsgnr: AW :ILC = 48 WT/PLY: 354 v V ra noted otherwise, top chord shall have property attached structural sheathing and bottom chord shall have a property attached rigid ceiling. Locations shown webs shall have bracing installed per sections B3, B7 or 810, as applicable. Apply plates to each lace of truss and /or permanent lateral rve TC Live 20.00 pelf LiveDar L=1.25 P=1.25 a II IILJ � I�fj\\�JI I IILr`J and an position as shown ebwa and an the .joint Details repoq unless noted otherwise. Cher TC SaoW (Pf) 0.00 pelf SaoWDar L=1.15 P=1.15 Alpine, a division of ITW Building Components Group Inc., shall not be responsible for any deviation from this drawing, any failure to build the truss in TC Dead 14.06 sf P Re Mbr Bad / Com / Teas P P AN /TW COMPANY conformance with ANSlrTP1 i. or for handing, shipping, installation S bracing of trusses. A seal on this drawing or cover page listing this drawing, Indicates acceptance of professional engineering responsibility BC Live 0.00 pelf 1.10 / 1.10 / 1.10 7670 N. Groat SIN Pkwy. Grand Prairfe, TY 75050 solely for the design shown. The suitability and use of this drawing for any structure Is the responsibility of the Building BC Dead 8.00 pier 0. C. Spacing a- 0- 0 Designer per ANSI/TPI 7 Sec.2 TRUSPLUS 6.0 VER: T6.5. 20 For more information see this job's general notes page and these websites: ALPINE: ww,v.eloineihv.com: TPI: www.[mnsLere: WTCk wwwsbcindusinjuz ICC: mvw.iccsafa.orn Bldg Code: CBC -2013 - - DBFL RATIO: L/240 TC: L/24 Job Name: SINGLE FAMILY RESIDENCE Truss ID: A01 F Qty: 1 1 BIG I -LOC Mel SIZE REQ'D 1 0- 2- 0 $51 4.05" 1.50" 2 1- 9-12 263 3.50" 1.50" 3 3. 7. 8 53 3.50" 1.50" 4 5- 5- 4 107 3.50" 1.50" S 7. 3. 0 366 3.50" 1.50" 68-10- 2 55 3.50" 1.50" 1 10- s- 4 9603.50" 1.56" 8 12- 4- 2 111 3.50" 1.5011 9 14- 3- 0 96 3.50" 1.50" 1016. 1.10 66 3.So" 1.50" 11 IS. 0.12 1462 3.50" I.So" 12 19- 6-12 -26 3.50 1.50" 13 21- 0-12 9711 3.50" 1.50" 14 22-10. 3 103 3.50" 1.50" 15 24- 7-10 100 3.50" 1.50" 16 26- 5. 0 1 3.50" I.SO" 17 28- 2- 7 1847 3.50" 1.50" IS 38- S. 4 1125 3.50" 1.50" 119 46-11.12 485 3.50" 1.50" MAE DEFLEITION (span) L/999MEN 1.2 (LINE) LC 40 1= -0.15" D= -0.21" T= -0.35" i o• o - 0 1z 0- o- 0 a :• 1. 0 13 7- 3- 0 3 10- 6- 4 14 10- 5- 4 4 u- 0-12 15 le- 0-Iz S19 a-u I6 119- ",0 zl- 0-12 17 21- 0-12 7 28. 4-12 118 28- 4.11 8 33. 5- 7 19 33- s- 7 9 38- 8- 4 20 38- e- 4 110 40- e- 4 2I 47- 1- 8 TC 2X4 Dpi. 81 8 Btr. 2x6 DPL 82 3-7 WC 2X4 DPL 81 ABtr. WEB 2X4 DFL STANDARD OIL BLE 2X4 DFL STANDARD Bearings designed for an PePery value of the lesser of the truss chord lumber value or 625 for all besriage. IRC/IBC truss plate values are based on testinngg and approval ::,re quired by IBC 1703 and AN and are orted in R-1118. Drainage shall be provided to avoid ponding. Bmilding designer shall verity gable loads and cave loads, if applicable. (+1 gable bracing required 0 42" intervals, If exposed owid Gablee Band plieo Details.face. SeeITWBC6'sBracing This truss is designed awing the ASC17-10 Wind Specification Bldg Enclosed = Yes, Truss Location = Not End Zone Eap Category = C 329 Length = 65.08 ft, ■lig Width = 72.33 tY Mean row height = 14.54 ft, ■ph = 110 Occupancy catsgory II, Dead Load = 13.2 psf Designed as Maim ®turf Force Bewiwting System - Low-rise and Components and Cladding Tributary Area = 200 sq£t ®Web bractog required at each location shown. Refer to BCSI £or proper required lateral restraint. For alternative web bracing, ase TYWBCG's standard details. Designed per ANSI/TTI 1-2007 pabrication Tolerance = 20.0% Ecr (creep factor) = 2.00 Refer to joint QC Detail Sheets for Cq factors and Rotational Tolerances. Loaded for 10 PSP non -concurrent BOLL. Bark all interior bearing locations. Install interior support(s) before erection. Permanent bracing is required to revent rotation/toppling. See [went ANSI/YPI 1. PLAYING BASED ON GREEN LUMBER VALUES. HORIZONTAL REACTION(S) : support 1 1359 Ib support 2 -9S1 Ib support 7 -143 lb support 17 -344 ib 20 psf Live Load applied to bottom chord in accordance with IBC/IBC code provisions. This design based on chord bracing applied per the following schedule: mall O.C. from to TC 24.00" 10- S. 4 28- 4-12 UPLIFT REALTION(S) Support CAC Wind Non -Wind 1 .29 lb 2 -58 Ib 3 .9 Ih -1 Ib 4 -1 Ib 5 -15 Ib 6 -1 Ib 7 -42 Ib 8 -1 Ib 9 -1 Ib 10 .1 Ib 11 -67 Ib 12 .119 Ib -290 lb 13 -43 16 14 -1 lb 1s .1 lb 116 -/ Ib .3 lb 17 -79 Ib IS .44 Ib 19 -74 ib TC 1-z C01R. R. / Tells. 1R. C8I •754 1.23 / e 1.60 0.57 10-5-4 17-11-8 5-0-11 13-8-1 �1 I I I Truss designed to support 1-0-0 top chord oatlookers z-3 3.9 •537 1.25 / .310 I.LS / 86 1.60 O.5Z 49 1.80 o.9z 2 3 4 5 6 7 8 9 10 11 and cladding load not to exceed 10 PSP one face, and s-6 -3334 i:zs i u i -m 0.It 2411 span opposite face. Top chord most not be cat or 6a -112 1.60 / lox 1.60 0.80 10.00 -10.00 -4.0 notched. 7.8 -zse 1.z5 / 106 1.25 6.45 1.5X4 8-9 9.10 -431 1.x5 / 1.23 / 2 1.60 0.21 61 1.zs 0.37 3X4 lora -30 -325 1.x5 / ss 1.2610 a." 7X8 1.5X4 6X8 a COY". ((DTR.))/ 78Ns. ((DDUI.) ISI 3X6 T 12.13 14.15 •e51(l.zijl i 433(1.60) o.z9 0.0022 f 6X6 1.5X4 11sas 116-v / / 0.01 0.12 g_1-1 3X4 9-1 -15 ie.is 11 358 21 o:ii I SHIP zo-ii (( - 41:68/ 210(1.25 0.41 1 2.5X4 3X6 it COMP.DUB. / TONS UN CSI x 3X4 x z-13 x•14 -293 1.zs / l.zs / o.1I 136(1.eo) 0.27 0-4-11 0-3-13 s�F$Gt 5X6 1.5X4 6X6 3X4 3-14 •318 -600 11.x5 / 0.21 1.5X4 B18 B19 1.5X4 v`f� Sas -14 1.50 / s7(1.2s) 0.003 3X4 T. TqN 4a3 -1438 11.x5 / o.s1 28-2-7 38-8-4�V 5.16 6.17 / -9x4 1.zs / 315(1.x5) 0.13 00.32 J 6.18 •496 1.zs / 0.28 7-18 6.18 -496 1.zs / -482 0.34 M 1.60 0.39 1 -HO 10 8-19 -ISO 1.25 / 39 1.25 10.ae 47_1_6 9 -IB 9-20 / -sa2�l.zs;/ 449 1.as O.IB s4 1.60 0.09 12 13 14 15 16 17 18 19 20 21 NO. C 72180 10-20 -418 1.25 / 90 1.60 0.07 TYPICAL PLATE: 1.5X3 S} CIVA, P 4�OFOpy1F All connector plates are ALPINE Wave 20 ga., unless preceded by "H' for High Strength 20 ga., "S" for Super OVER SUPPORT AS SHOWN Strength 18 ga. Plates are to be positioned per Joint Detail Report. Circled plates and false frame plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates. 5/6/2016 268 - Homewoodross **WARNING!** READ AND FOLLOW ALL NOTES ON THIS DRAWINGI Cast: LEWIS WILLIAMS (TCA) **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. DIB: Drive_M_0220316_L00007_j00001 require e><trame cera in fabricating, handing, shipping, installing and bracing. Refer to and follow the latest edition of SCSI (Building Component W0: Drive_M_0220316_L000 W Setety Information, by TPI and rCA) for safety practices prior to performing these functions. Instagers shall provide temporary bracing per BCSI. Unless Dsgur: AW :ILC = 48 WT/PLY: 667 V VTrusses In, noted otherwise, top chord shall have property attached structural sheathing and bottom chard shall have a property attached dgid ceiling. Locations shown have installed BCSI 83. B7 BtO, Apply to lace truss TC Live 20.00 psf LiveSnowDur L=1.25 P=1.25 _ ��� r� rt r� l�r��\V\IJII'ILr�J bracing per rre or as applicable. plates each of and for permanent lateral restraint n waits int D otherwise. position as shown above and on the Joint Details report, unless noted oNerwise. TC Snow(I'll) 0.00 psf SIIOWDtIr L=1.15 P=1.15 Alpine. a division of ITW Building components croup Inc., shall not be responsible for any deviation from this drawing, any failure to build the truss In TC Dead 14.00 psf Rep Mbr Bud / Comp / Tens AN /TW COMPANY conformance with ANSIrfPI 1, or tot handling, shipping, installation 5 bracing of busses. A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineering responsibility BC Live 0.00 psf 1.00 / 1.00 / 1.00 2870 N. Graaf SW Pkwy. Grant P.Ilio, TX 76050 solely for the design shown. The suitability and use of this drawing for any structure Is the responsibility of the Building BC Dead 8.00 psf 0. C. Spacing 2- 0- 0 Designer per ANSVTP/ 1 Sec.2 TRUSPLUS 6.0 VEE: T6.5.20 For more information see this job's general notes page and these web sites: ALPINE: wwwaloneiweamtTPI: wwwtolnsLom:vJTCA:sura-abcindusM.omtICC: vaw.ieesafe.ora - Bldg Code: CBC -2013 DBPL RATIO: L/240 TC: L/24 Job Name: SINGLE FAMILY RESIDENCE Truss ID: A01S Qty: 1 ERG I -LOC SHALT SIZE REQ'D TC 2x4 DFL 41 i Str. Well, bracl required at each location shown. This designbased on chord bracing applied , flowing 1 0- 1.12 922 3.50" 1.50" 2 '17-10- 4 853 3.50" 1. SO" SC 2x4 DFL 61 A Btr. WEB 2x4 DFL STANDARD ® Refer t!n6 for proper required lateral* restraint. For alternative web bracing, per the schedule: max o.c. from to MAX DEFLECTION (span) t Designed per ANSI/TPI 1-2007 see ITWRCG'a standard details. 20.0% TC 24.00" 10- S. 4 18- O- 0 UPLIFT REACTIONS) L/999 IM 8-9 (LIVE) LC 40 L= -0.15" D= .0.14" T= .0.29" Bearings designed for an FePerp value of the lesser of the truss chord lumber value or Fabrication Tolerance = Ser (creep factor) = 2.00 : Support CAC Sind Non -Wind -_ ).tat tocatim m 625 for all bearings. Refer to Joint QC Detail Sheets for 1 -9 lb i 0- o- o e e- 0- o IRC/IBC truss plate values are based on Cq factors -and Rotational Tolerances. 2 -131 I► " x 7- a- 0 1 1- a- 0 1 t0- s- 4 8 te- s- 4 teat Ing and approval um required by IBC 1703 - in R-1118. Loaded for 10 PSF non-concumaut BCLL. - Droi be to HORIZONTAL RPACTION(S) s rt 1 287 Ib upp° 4 14- z-10 s 18- o- onepending. and ANSI/TFI and are reported designed for loads a shall provided avoid ndi PLATIN BASED ON GREEN LOIBBS VALUES. support 2 287 Ib s 16- 0. 0 nMCAL mon 1roRM. End verticals are anal only, unless noted otherwise. This trums is desiumed acing the Bldg Code: CBC -2013 TC Col?. Om. / T®t4. Ota. 1sT EO psf Llve toad applied to bottom ckord in ASCE7-10 Wind Specification 1-z 898 x-1 -los t.zs / u 1.60 0.18 1.zs / et 1.60 0.16 accordance with IBC/IBC code provisions. Bldg Enclosed = Yes, 1.4 -ass LLs / 7E 1.80 0.16 7rums Location = Not End Zone 4-s o 1.eo / 0 1.xs o.aa Category = C tx w10. (DOt. / res. m. CSI BE dg Length = 65.08 ft. Bldg Width = 72.33 ft 6-7 -fez(1.6033/ ase 1.23 0.x8 Ee- roof height = 14.54 ft, �h - 110 Occupancy Categwry II, Dead Load 13.2 tsz(1.so3/ 655 l.xs 0.41 / = psf Designed ee Salo Wind Force Resisting System S'.e 71(((1.60 291 1.x5 0.41 -low-rise and Components and Cladding . is Coir. (bOt.)/ TIXS. n. CSI Tributary Area = 38 sgft x-7 / te9((D1.253 o.oe .40 Z-8 -eat((t.xs)/ xW(1.60) 0:- ' 3-8 -14(1.80 / z41 1.x5 0.10 3 4-6 az((((((I go / 411 1.xs 0.18 4-e 7 1 1.25 / 140 1.60 0.1z - 3.9 -103 I.zs / 32 1.60 0.04 10-5-4 2 3 7N2 5, F10.00 2.5X4 9-1-1 .t 3X6 2 0-4-11 1.5X3 3X6 3X4 B1 B2 W:308 W:308 R:922 R:953 U:-9 U:-131 18-0-0 r , I6 7 8 0_T 9-10-15 SHIP rxY�yFy-T. TqN 1 No. C 72160 CIV OF InAUV: All connector plates are ALPINE Wave 20 ga., unless preceded by "H' for High Strength 20 ga., "S' for Super Strength 18 ga. Plates are to be positioned per Joint Detail Report. Circled plates and false frame plates 5/6/2016 are positioned as shown above. Shill gable stud plates to avoid overlap with structural plates. 268 - Homewood Truss "WARNING!" READ AND FOLLOW ALL NOTES ON THIS DRAWING/ Cant: LEWIS WILLIAKS (CA) **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. DIB: Drive_It_0220316_LO0007Jj00001 /\ Trusses ra4uire aa,,,*,, care in 111,1111119, hamming, shipping, installing and bracing. Refer to and follow the latest edition of SCSI (Building Component W0: Drive_M_0220316_L000 159 /���\1 Safely Information, by TPI and WICA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless DSgur: AW #LC = 42 WT/PLY: tV noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a property attached rigid ceiling. Locations shown lace truss TC Live 20.00 psf - - LiveSnowDnr L=I .25 P-1.25 O I�r��\V\I,JII ��� r� rr installed per Cherise.sections B3, B7 or 810, as applicable. APPN plates to each of and for permanent lateral restraint of webs shall have report position as shown above and on the Joint Details repoK unless noted otherwise. TC Snow(Pf) 0.00 psf SaowDur L=1.15 P=1.15 Alpine, a division o1 ITW Building Components Group Inc., shag not be responsible for any deviation from this drawing, any failure to build the truss in TC Dead 14.00 psf Rep ilbr End / Comp / Tens AN ITW COMPANY conformance with ANSIrIPI 1, or for handling, shipping, installation 8 bracing o1 trusses. A seal on this drawing or cover page listing this drawing, Indicates acceptance of professional engineering responsibility BC Live 0.00 psf 1.10 / 1.10 / 1.10 2820 N. Groat SWPkwy. Grand P.M., TX 76050 solely for the design shown. The suitability and use of this drawing for any structure Is the responsibility of the Building BC Dead 8.00 psf 0. C. Spacing 2- 0- 0 Designer per ANS1/rPl 1 Sec.2 TRUSPLUS 6.0 VER: T6.5.20 For more information see this job's general notes page and Nese web sites: Bldg Code: CBC -2013 DEFL RATIO: L/240 TC: L/24 ALPINE: wwwaleineliwcmmrTPl;wwwlnn,�n WiCA wwwsbcindustrvora ICC:wwwiccaefnnre Job Name: SINGLE FAMILY RESIDENCE Truss ID: A01SA Qty: 1 BIG 1 -LOC REACT SIZE BEQ TC 2x4 DPL 81 A Btr. Web bracing required at each location shown. This designbased on chord bracing applied OD 1 21-'7-12 . 892 3.50" 3,50" BC 2z4 DPL B1 8 Str. ® Refer to BCSI for proper required lateral per the flowing schedule: 2 38- 1'-'1500 3.50" 1.80 VER 2x4 DPL STANDARD restraint. For alternative web bracing, - maz o.c. from to 3 40-11-12 411 3.50" 1. s0" 2z6 DPL #2 8-1 see ITWBC6's standard details. TC 24.00" 10. 5- 4 28- 4-12 SAY DEFLECTION (span) : L/868 1®f 11-12 LC 42 NUG BIL 2.4 DPL STANDARD Deafened per ANSI/TPI 1-2007 UPLIFT' REACTION(S) : - (LIVE) L=-0.11" D= -0.18" T= .0.29" Bearings designed for an FcPerp value of the lesser of the truss chord lumber value or pabricatian Tolerance = 20.0% Ker (creep factor) = 2.00 Support CRC Wind Non -Wind - 1 -163 lb FIX .WE DEF CRITEM:L/120 625 for all hearings. Refer to Joint QC Detail Sheets for 2 -92 lb IN MEN 0. 0; T= 0.28" IRC/IBC truss plate values are based on Cq factors and Rotational Tolerances. Da 3 -72 Ib ... ,pint locattaaa -- testi sad approval as required by LBC 1703 for 10 PSF non-coacurrent ICU. HORIZONTAL REACTION($) I o• o- 0 7 zs. 4. 0 x x- 4- + s s- o- o and ANNII/7PI and are reported In R-1118. Baric all interior bearing locations. support 1 -440 Ib a 6- 7- + e R- 7- + . + r ... r ...... ♦ .. r ..... " Install interior supports) before erection. support 3 -440 Ib 4 lt- 7.15 10 11- 7 -IS Dares rained hertz. LL deflection = 0.27 Drat a shall be provided to avoid pending. mmgg p Po nB• PLAT)717 WIN.. ON GREEN LUMBER VALUES. using 7'hts truss is designed ass the ASCET-10 Wind Spec fication s 16-10-Iz 11 lea.-lz 6 18.10-12 is zs- 4. 0 + ..................... 20 psf Live Load applied to bottom chord in End verticals are designed for "let loads Bldg Enclosed =Yea, CRM tMER FORCES' accordance with IBC/IRC code provisions. only, unless noted otherwise. Truss Location = Not End Zone ID. / 71N3. IR. t-2 •ixa t.8- TC COMP[.Ili CSI Category = C Bl Lenath 65.08 fc, Bldg Width = 72.33 fY3-4 3400 1.8 •87l.xs / 168 1.60 o.1t 0.19 = Mean roof height = 14.54 ft, ■ b = 110 4•s.1.60o.xOccupancy Cate o II, Dead Load = 13.2 psf s-6 z76eo / ass 1.eo sot.so / zea 1.eo 001s•7 0.41 Deslgoed as :no Ind Force teaisting System - Low-rise and Components and Cladding ce a1v.(0m.)/ a1tC5. (OUR.) Iii 7ribatary Area = 51 sgft too{!/ tel t.zs{! 0.31 R•e an Vertical mambas exposed to wind: 0- 0 e•lo •161 t.eo / ale 1.zs o.28 1.•11 -leo 1.zs / 78 1.60 O.ze n-lz -159 1.60 / tae 1.xs 0.27 17 COMP. BUR. / TENS. BUR. CSI RR 1 .977 1.2a / x48 1.60 0.87 1-8 -158 1.60 / 684 1.25 0.87 x-8 -778 l.xs / 187 1.60 O.L9 z -s ua 1.eo / 49s l.21 o.10 3-9 •128 1.60 / 154 1.60 0.05 4-9 -251I.xS / 120 1.60 0.21 4.10 -3a4 1.25 / 74 1.so 0. It - - sag •59 1.60 / 876 l.zs 0.38 S-11 -804 1.xs / 113 1.60 o.15 6a1 -410 t.zs / 99 2.60 0.07 -10.0 -4.0 T. No. C 72160 �? CfV{1.- P ��dF CAUF AU connector plates are ALPINE Wave 20 ga., unless preceded by 'H" for High Strength 20 ga.,'S' for Super Strength 18 ga. Plates are to be positioned per Joint Detail Report. Circled Fates and false frame plates c itR structural plates. - •• - - -. - - - - /20 A 1 6 - re positioned as shown above. Shift gable stud plates to avoid overlap - - - - 516/201 aw516 Z68 - Homewoodruss "WARNING!"'* READ AND FOLLOW ALL NOTES ON THIS DRAWINGI Cust: LEWIS WIUUL14S (TCA) "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. DIB: Drive_11_0220318_1,00007_ j00001 require extreme ca,e in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component W0: Drive_ii_0220310_L000 Safety Information, by TPI and WTCA) fn, safety practices prior to performing these functions. Installers shall provide temporary bracing Der SCSI. unless Dsgnr: AW #LC = 50 WI/PLY: 2184 v VTrusses to noted otherwise, top chord shall have property attached structural sheathing and bottom chord shall have a property attached rigid ceiling. Locations shown installed B3, B7 870, Apply to lace truss TC Live( 20.00 prof LiveSnowDur L=1.25 P=1.25 ^ n lU�\vl I ALM lateralwn ab restraint n webs int D have report, per Cher sections or as applicable. plates each of and for pe,mas shown position as shown above and on Na Joint Details report, unless utatl otherwise. TC $LOW P 0.00 psf f) $IIOWDOr L=1.15 P=1.15 Alpine, a division of ITW Building Components Group Inc.. shall not be responsible for any deviation from this drawing, any failure to build the truss in TC Dead 14.00 psf Rep Hbr Bnd / Comp / Tens AN ITW COMPANY conformance with ANSIfTPI 1, or for handing, shipping, installation 6 bracing of cusses. A seal on this drawing or cover page listing this drawing, Indicates acceptance of professlonal engineering responslbility BC Live 0.00 psf 1.10 / 1.10 / 1.10 2620 N. Great SIN Pkwy. Grand Proble, TX 75050 solely for the design shown. The suitability and use of this drawing for any structure Is the responsibility of the Building BC Dead - 8.00 psf 0. C. Spacing 2- 0- 0 Designerper ANSI/TPI I Seat _--_ TBUSFLOS 6.0 VER: T6. rJ . 2D For more information see this job's general notes page and Nese web sites:- - - ALPINE: ww.v aloinritw.com: TPI: ww minst-era WTCA www.sbcindastm ere' ICC: www I ceafe ere goe: - Bldg CdCRC-2013 DEFL RATIO: L/240 TC: L/24 Job Name: SINGLE FAMILY RESIDENCE BIG X -LOC REACT SIZE REQ'D TC 2a4 DFL i1 4 Btr. 1 0- 1.12 1933 3.50" 2.08" RC 2a4 DFL 41 6 Btr. 2 17-10- 4 1013 3.50 1,50" FILL CHO - 2a4 DFL STANDARD 3 38- 8. 4 3118 3.50" 3.33" WEB 2r4 DFL STANDARD 4 46-11.12 233 3.50" I. SO" 2x41 DFL 41 It Btr. 19.8 mAX DEFLECTION (span) : FLT HLl 2" DFL 42 L/099 M 5-6 (LIVE) LC 42 SIR BLE 2a6 DFL F2 L= -0.18" D= -0.24" T= -0.42" Ecr (creep factor) = 2.00 -_= Jeiat L-tiraa o Refer to Joint QC Detail Sheets for i 0• o• 0 I2'_3- 0 Cp factors and Rotational Tolerances. E 7• S- 0 13 10- 5. 4 IlC/IBC truss late values are based on P 3 10- S. 4 14 11-10- 4 4 17.10. 4 15 ze- 0- 0 5 z4. 1 -IE 18 zz• o• 0 testing and approval as required IBC 1703 and AN and are reported In 1-1118. D z8- 4-1E 17 24- 1-1z 7 33. 5. 7 IB ze- 4-12 Drainage shall be rovided to avold ponding. B 18- e- a Io 31- s- 7 B 40. 8• a 20 38- 8- 4 PLATING BASED ON 6� LUIlIER VALUES. 20 prof Live Load a lied to bottom chard in P 10 47 .1• D zl 47- 1- B accordance with IB IIIc code provisioum. CRITICAL Designed ae Main Wind Force Resisting System - Low-rise and Components and Claddimg 1®088 FORCES. 7t COIR. DOT. / TINS.(DUR.) CSI tributaryArea = 94 sgfY 1-2 -2431 1.25 / 0.89 -----.----LOAD CASE 41 DESIGN LOADS ---------------- 2-3 -2068 1.25 / 7J 1.60 0.33 3-4 -1811 I.LS / 4 1.60 0.81 Dir L.Pif L.Loc R.Pif R.Loc 4-3 -I= I.Ls / 3 11 0.81 TC Vert 84.00 - I- 0- O 84.00 0- 0- 0 3-6 -1828 1.2s / L 1.80 o.lt 6.7 -loos 1.2s / L7 1.60 0.z1 TC Vert 68.00 0- 0- 0 68.00 17-10- 4 7-8 -1870 1.25 / L4 1.60 O.L6 TC Vert 88.00 17-10- 4 88.00 24- 1-12 8.9l.t3 0.81 TC Vert 68.00 Z4- 1-12 68.00 47- 1. 8 8.10 / lEIB 1.25 0.58 TCVert 84.00 47- 1- 8 84.00 48. 1. 8 BC CORP.(BUR.)/ TOTS. LSI KVert 16,00 0- 0- 0 16.00 17-10- 4 11.1E / 1750FIBI 0.43 BC Vert 106.00 17-10- 4 106.00 24. 1-12 1L-1317485013.14 BC Vert 16.00 24. 1-12 16.00 47. 1- 8 / 15155 0.14 IAds / 18385 0.79 .Type... lbs I.Lac LL/TL Fastener IS -1819385 0.4z I5 -I6 -808(0.90)/ 0.25 16./7 / E4ss 1.25 0.44 17-18 / 1449 l.zs 0.35 10-5-4 18-19 / I= 1.25 0.33 19-20 -lLB4 1.25 / 0.33 r1 2 3 20-21 -1077((1. L5 / 0.45 l4-.1 -81(1.25 / 89(1.60) 0.ES 10.00 I6-17 •EL0(t.25 / 0.2E B7 camp.(DUI.)/ TORS. Ue. CSI E-12 / 255 1.25 0.10 6X6 2-13 -498 1.z5 / lollL1 OAL 3.13 •12l 1.60 / 11301.25 O.to 3.14 -86 1.25 / 7771.25 4.14 •637 LIS / 361.60 0.85 OAS 3X6 sa7 •546 LLS / 0.38 6.17 / 013 1.25 0.16 B-18 -146(1.60)/ 142 I.LS 0.08 7.18 / 176 0.90 0.10 9-1-1 7.199 •1331(1.25)/ 0.48 8 -IB / 2834(1.25) 0.38 10X14 S.Z. -2498 1.23 / 0.41 8•LO •426 t.E5 / BE(1.60) 0.07 3X6 TB CONP.(DUB.)/ Irm.0ult.) CSI x 1.5X4 0-4-11 3X4 B1 W:308 17 , R:1933 U: 18-0.0 1�0 0 11 12 13 TYPICAL PLATE: 3X4 7X1 71# Truss ID: A02 ® Web bracing required at each location shown. Refer to SCSI for proper required lateral restraint. For alternative web bracing, see rTWSCG's standard details. Designed per ANSI/TPI 1-2007 Fabrication Tolerance = 20.0% Bearings designed for an Fcliery value of the lesser of the truss chord lumber value or 82S for all bearings. Attic room load = 45 psf, los any added loads indicated. Room LL ft. is L/380. Loaded for 10 PSP non -concurrent BCLL. Harte all interior hearing locations. Install interior support(o) before erection. Attic collar tie requires lateral restraint shown plus bracingat the panel points of the Miler tie (anlesa meted otherwise), or rigid sheathing is required. 17-11-8 1 5-0-11 1 13-8-1 4 5 6 7 8 9 10 r -10.00 4.0 1.5X3 1.5X4 5X8 4 This design based on chord bracing applied A per the following schedule: 6X6 1.5X4 6X8 max O.C. from to TC 24.00" 10- 5- 4 28- 4.12 5X8 UPLIFT REACTION(S) : B2 4X8 Support ' C&C Wind Non -Wind 134 4 -198 lb -161 Ib W:308 HORIZONTAL REACTIONS) R:1013 support 1 435 1► R:233 support 4 -235 lb U: This Cross is designed using the ASCE7-10 Wind Specification Bldg Enclosed = Yes, 1-100 Truss Location = Not End Zone Category = C 14 15 16 17 18 Bldg Length = 65.08 ft, Bldg Width = 72.33 ft ft, 110 21 mean roof height = 14.S4 mph = Occupancy Category II, Dead Load = 13.2 psf Designed ae Main Wind Force Resisting System - Low-rise and Components and Claddimg tributaryArea = 94 sgfY -----.----LOAD CASE 41 DESIGN LOADS ---------------- Dir L.Pif L.Loc R.Pif R.Loc LL/TL TC Vert 84.00 - I- 0- O 84.00 0- 0- 0 0.48 TC Vert 68.00 0- 0- 0 68.00 17-10- 4 0.59 TC Vert 88.00 17-10- 4 88.00 24- 1-12 0.45 TC Vert 68.00 Z4- 1-12 68.00 47- 1. 8 0.59 TCVert 84.00 47- 1- 8 84.00 48. 1. 8 0.48 KVert 16,00 0- 0- 0 16.00 17-10- 4 0.00 BC Vert 106.00 17-10- 4 106.00 24. 1-12 0.74 BC Vert 16.00 24. 1-12 16.00 47. 1- 8 0.00 .Type... lbs I.Lac LL/TL Fastener TC Vert 0.0 0- 1-12 1.00 TC Vert 0.0 46-11-12 1.00 BC Vert 71.2 17-10- 4 0.00 1C Vert 71.2 24- 1-12 0.00 1.5X3 6-0-0 11 A 6X6 1.5X4 6X8 3X6 x 3X4 3X4 5X6 5X8 0-3-13 B2 4X8 3X4 133 134 W:308 W:308 W:308 R:1013 4 38-B R:3118 R:233 U: 71#1 U: U:-188 1-100 47-1-6 14 15 16 17 18 19 20 21 All connector plates are ALPINE Wave 20 ga., unless preceded by "H' for High Strength 20 ga., "S" for Super OVER 4 SUPPORTS Strength 18 ga. Plates are to be positioned per Joint Detail Report. Circled prates and false freme plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates. 268 - Homewoodruss **WARNING!** READ AND FOLLOW ALL NOTES ON THIS DRAWING! (TCA) **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. /\ Trusses re quite extreme care in fabricating, handing. shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and WrCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per SCSI. Unless ry noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a property attached f orf ceiling. Location shown ��� r� rt for permanent lateral nab restraint n webs intshall have bracing interred per other section B3,87 or 670, as applicable. Appy Plates to each lace of truss and jam\ I I`v I.I postcon as shown above endo f thewa Joint Details report, installed noted otherwise. u v�.l Alpine, a division of ITW Building Components Group Inc., shall not be responsible for any deviation from this drawing. any failure to build the truss in AN ITW COMPANY conformance with ANS1rrPl 1, or for handling, shipping, Installation 8 bracing of trusses. A seal on this drawing or cover page listing this drawing, Indicates acceptance o/ professional engineering responsibility 120 N. Great SW Pkwy. Grand Prairie, rX 76050 solely for the design shown. The suitability and use o/ this drawing for any structure Is the responsibility of the Building Designer per ANSI/TPI 7 Sec.2 TflUSPLUS 6.0 VER: T6. S . 20 For more information sea this job's general notes page and these web sites: ALPINE: wmv a TPI: wwwtoifi= WfCA www =be_indust. or, ICC: www.icesafe are 9-19-15 SHIP / T. No. J No. C 72160 CN1l P q�OF 5/6/2016 DIB: Drive_B_0220316_L00007-J00001 W0: Drive_M_0220318_L000 Dsgnr: AW #LC = 90 WT/PLY: 38 TC Live 20.00 psf Livellar L=1.25 P=1.25 TC Saow(Pf) 0.00 psf SnowDar L=1.15 P=1.15 TC Dead 14.00 psf Rep llhr Bud / Comp / Teas BC Live 0.00 psf 1.10 / 1.10 / 1.10 BC Dead 8.00 psf O.C.Spacing 2- 0- 0 Code: CBC -2013 IDEFL RATIO: L/240 TC: Job Name: SINGLE FAMILY RESIDENCE Truss ID: A02A Qty: 1 BIG R -LOC REACT SIZE REQ'D TC 2x4 DPL 81 a Stir. Web bracing required at each location shown. This deal based on chord bracing applied 1 0- 1.12 2129 3.50" 2.27" 211:8 DPL i2 3-6 ® Refer to MY for proper required lateral per the following schedule: 2 17-10- 4 1119 3.50" 1.50" RIC 2z4 DPL F1 k Btr. restraint. For alternative web bracing, ■az 0. C. from to 3 38- 8. 4 3520 3.50" 3.50" 2x8 DFL SS 14-16 see ITWBCG's standard details. TC 24.00" 10- S- 4 28- 4.12 4 46-11.12 IBS 3.50" 1.50" FILL CHD 2x4 DFL STANDARD Designed per ANSI/TPI 1-2007 UPLIFT REACTION(S) : BIG RBINFORCE)B11T: WEB 2x4 on STANDARD Fabrication Tolerance = 20.0% Support C&C Wind Noo-Wind BIG TYPE FACES NAILS LENGTH 2z4 DFL 41 It Btr. 17-8 Bearings designed for an VcPerp value of the 1 .83 lb 3 BIB 1 13 18" SCAB 2x4 DFL Y1 a Str. lesser of the tress chord lumber value or 2 -42 lb HAI DEFLECTION (span) :� 42 FLT BLB 2x8 DFL 42 825 for all bearings. 3 .141 ib L/999 MEN 14-1S ( ) Refer to Joint QC Detail Sheets for Rcr (creep factor) = 2.00 4 -246 Ib -261 Ib L= -0.20" D= -0.29" T= •0.49"fq factors and Rotational Tolerances. Attic roo■ load = 45 psf, &las IZO any added HORIZONTAL REACTION(S) _=I.1ot 1-ti•n C/IBC truss plate values are based on loads indicated. Roan LL fl. is L/380. support 1 -234 lb i a• o• o ll e- o- o testi and approval u fired by IBC 1703 Loaded for 10 PSF nen-concurrent BCLL. a rt 4 .234 lir Z 7. a• o 112 I- 3- a required ES tra s lo• s• 4 is le- s- 4 and ANnlI/TPI and are reported I. I-1118. Bark all interior bearing locations. This trr7sa Is designed using the 117 -to- 4 114 17- s- a Drainoaagge shall be provided to avoid ponding. Install interior support(s) before erection. ASCE7.10 Wind Specification 5 24. 1-19 115 114- 11-1111 11ATING BASED ON G� LIMBER VALUES. Attic collar, tie requires lateral restraint Bldg Enclosed = Yes, 6 33 4a7 w 29- 4-112 Brg. Block Reinforcing ■ember: shown plus bracing at the panel plots of Trans Location Not End Zone 7 33- s- 7 117 aa- s• 7 Attached to required faces of the tans the collar tie unless noted otherwise Category= C 8 38- B. 4 IS 3 - a• 4 regw O ( ) B 40• s• 4 IS 47- 11- 9 at the noted support(s). Attach each block or rl id sheathing is required. B1 Length - 85.08 ft, Bldg Width = 72.33 ft to 47- 11- a with lOd Hutton moils as indicated evenly 20 Live Load �pplied to batto■ chord in Bean roof height = 14.54 ft, ■ h = 110 ramCkll®Bn lolces: a ced and staggered tbroaghowt, per NDS. accordance with IRC/IRC node provisions. Oeewpancy Category II, Dead LaaS = 13,2 psf >r C910. em. / T®144. (BU9.) C79 Blocks shall not an tie-in loads. Desi ed as Halo ®Ind Forge Resists S sten 42 -2727 1.25 / o.7e O C°r''S y tin n� Sy stew .E375 1.23 / 0.41 - Low-rise and Cosyoneats and Cladding a-4 -2264 11..5 / o.90 Tributary- AreaAD CASE581 DESIGN (AADS ---------------- 4•S -2283 1.x5 / ' 0.20 ........ 5-6 -2.81 1.25 / 0.38 e-7 -.a75 l.as / 0.23 Dir L.PIf L. Loc R.PIf 1. Loc LL/71. 7-8 -1447 1.x5 / 0.12 TC Vert 84.00 - 1- 0- 0 89.00 0. 0- 0 0.48 e-9 / 11792(11.x5) 0.7. TC Vert 88.00 0. 0. 0 88.00 1T-10- 4 0.59 9-110 / 1494(11.x5) 0.69 TC Vert 88.00 IT -10- 4 88.00 24. 1-12 0.45 ce afv.(0m.)/ T9NS. N. CS7 TC Vert 88.00 24. 1.12 68.00 47. 1- 8 0.59 11-1111 / 11978 11.x3 0.51 TC Vert 84.00 47- 1- 8 84.00 48- 1- 8 0.48 IL-13 / 1875 1.23 0.48 BC Vert 18.00 0- 0- 0 18.00 1T-10- 4 0.00 13-14 / 1743 11.x5 0.io BC Yert 106.00 17-10- 4 108.00 24- 1-12 0.75 14-15 / Zags 11.x3 0.85 15.18 / 1738 I.z5 0.zo 10.5-4 17-11-8 5-0-11 13-8-1 BC Vert 16.00 24- 1-12 16.00 47- 1- a 0.00 16-v / 14721 0.41 I I i 7yp e... lbs I. Loc LL/TL Fastener 17.18 -1343(1.x5)/ o.se �1 2 3 4 5 6 7 8 9 10 TC Yet 0.0 9- 1-12 1.00 18.19 -W5a 1.25i)/ O.SE 6-3-8 TC Vert 0.0 46-11-12 1.00 R C01@.(BDI.)/ TOTS. IR. CSI 10.00 -10.0 -4.0 IC Vert 71.2 17-10- 4 0.00 2.12 / 238 11.za 0.10 BC Vert 613.0 21- 6-12 0.48 Z-la-507t(1.is) / les 11.so 0.41 BC Vert 71.2 24- 1-12 0.00 3.13 -128(1.60)/ BOB 11.zs o.E7 7X8 1.5X4 1.5X3 1.5X4 7X8 3.14 / 1101 i.s 0.45 4-14-777(1.zs)/ a 11so o.a7 T s -1s -247 1.xs / e. 1.60 0.08 6•ls / esti 1.00 0. so s-le-lss(L00)/ e7 11.zs 0.05 3 6 1.5X3 7.16 / 32011.00 o.16 6X6 7-17-1s88p.zs)/ o.sr 8-17 / 73I5(11.L5) 0.4E 9-1-1 8-118 -2992 1.zs / 0.48 7X8 1.5X4 9-10-15 Bae •4ze�l.zs�/ eop.eo) 0.07 I 1OX14 SHIP T9 CatR.(DUI.)/ T98s.(DUN.) CSI 1 3X6 6-3-8 3X6 x ri-= 0-4-11 1.5X4 3X4 8X10 7X8 6X8 0-3-13 Q�OFESI B1 8X10 3X4 B3 B4 R:212 17-10-4 38-8-4 W:308 R:185 ` _`�, T. j� R:2129 I R:3520 R:185 U:-83 71# 613# 1 1`1# U:-141 U:-261 - y' 24-3-8 1AI0 1T�o' 0 No. C 72160 47-1-8 11 12 13 14 15 16 17 18 19 r B2 R:1119 R:111 �4 CfV1%, P TYPICAL PLATE: 3X4 U:42 OVER 4 SUPPORTS �� GAu� All connector plates are ALPINE Wave 20 ga., unless preceded by "H" for High Strength 20 ga., "S" for Super Strength 18 ga. Plates are to be positioned per Joint Detail Report. Circled plates and false frame plates c /� A Q - are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates. 5/6/2016 5I6I2O 16 268 - Homewoodrass **WARNING!** READ AND FOLLOW ALL NOTES ON THIS DRAWING/ Cast: LEWIS WILLIAMS (TCA) **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. DIB: Drive_)1_0220316_L00007_J00001 T........4uira enreme care in rabrimIng, handling, shipping, installing and bracing. Refer to and follow the latest edition of SCSI (Building Component WO: Drive_M_0220318_L000 Safety Information, by TPI and WTCA( for safety practices prior to performing these functions. Installersshall provide temporary bracing per SCSI. Unless Dsgnr: AW *LC = 80 WI/PLY: 398 v V 1111. noted otherwise, top cha.d shall have property attached structural sheathing and bottom chord shall have a property attached dgid ceiling. Locatiorre shown face TC Live 20.00 LiveSnowDor L=1.25 P=1.25 ��� ^ n lu�\vl I for permanent lateral restraint n webs snap have bracing installed per SCSI sections 63, B7 or 810, as applicable. Apply plates to each of truss end position as crown above eft on the Joint Details repo.( unless noted otherwise. psf TC SaOW P 0.00 9f ( � SaOWDur L=1.15 P=1.15 Alpine, a division of ITN Building Components Group Inc., shall net be responsible for any deviation from this d.awing, any failure to build the truss in TC Dead 14.00 psf Rep ilbr End / Camp / Tens AN /TW COMPANY conformance with ANSIRPI 1, or for handling, shipping, installation 9 bracing o1 trusses. A seal on this drawing or cover page listing this drawing, Indicates acceptance of prefesslonal engineering responsibility BC Live 0.00 Pifer 1.00 / 1.00 / 1.00 2620 N. Great SIN Pkwy. Grand Prafrio, TX 75050 solely for the design shown. The suitability and use of this drawing for any structure Is the responsibility of the Building BC Dead 8.00 psf 0. C. Spacing 2- 0- 0 Designer per ANSI?PI t Se0.2 TRUSPLUS 6.0 VER: T6.5.20 For more information see this job's general notes page and these web sites- ALPINE: wmvalsilw om'TPtwwwloinstora WTCA: www sbeindustrcOra 'ICC:WwWieesafeof, Bldg Code: CHC -2013 DEFL RATIO: L/240 TC: L/24 f Job Name: SINGLE FAMILY RESIDENCE Truss ID: A03 Qty: 5 RRG 1 -LOC REACT SIZE RE ;0 TC 2u4 'DFL pl b Btr. Web bracing required at each location shown. This designbased on chard bracing applied 1 0- 1.12 546 3.50" 1.50" 2 917-10- 4 2445 3.50" 2.81" EC 2B4 DFL 81 4 Btr. ® Refer to SCSI for proper required lateral WER 2a4 DFL STANDARD restraint. Por alternative web bracing, per the following schedule: u" 0. C. Pros to 3 SS- 8- 4 1564 3.50" 1.87" Besieued per ANSI/TPI I-2007" see rMCG's standard details. TC 24.00" 10- S- 4 28- 4-12 ` 4 46-11-12 358 3.50" 1.50" MAX DEFUWrXON (spam) - Dear age designed for are PePetrpp value of the Fabrication Tolerance = 20.0% UPLIFT REACTION(S) : : L/896 HEN 18719 (LIVE) LC 40 lesser of the tress chord lauber value or Rcr (creep factor) = 2.00 625 for all bearings. Refer to Joint QC Detail Sheets for Support CtC Wind Non -Wind 1 .121 Ib L= .0.28" D= -0.27" T= -0.55" IRC/LRC truss plate values are based on Cq factors and Rotational Tolerances. 3 -139 lb =>+J•iat Leatiw ® 1 o- 0- 0 12 a- 1. 8 testing and approval as required by IBC 1703 Loaded for 10 PSF non -concurrent KIL. 4 -61 1h z 7= 3- 0 ll D- o- 0 and AN and are -parted in ESR -1118. Hark all interior hearing locations. sha3 Install Interiors rt(s) before erection. Drabe to avoid HORIZONTAL REAC'QON(S) support I -235 lb e• 009173o 4s el Provided Mnding. Tie°designed acing the PLAYING BASED ON GREEN LUMBER VALUES. support 4 -235 Ib 4o 8: 0• s• + .111:101-11 16 110- s- 4 ASCET-10 Wind Specification 20 psf Live Load applied to bottom chord in e " 17• e• a l; Enclosed = Yes, accordance with Is IRC code provisions. 724. 1 -IE IB L4. 1.12 8 Ea• 4.12 1e 33- s - 7 9 33. 5. 1 EO 38. 8. 4 Trusts Location =Not Ind Zona Erp Category = C 10 3B- s- 4 21 n• 1- a Bldg Lcsath = 65.08 ft, Bldg Width = 72.33 ft II40• e- 4 lean ate' Mean reof height = 14.54 M, ■ph = 110CRM s TC 0 TC aur. out. / TENS.19Din. CSI Ocrnpanry Category II, Dead Load = 13.2 psf 1-L -437 1.25 / 190 1.60 0.36 t•3 I.Es / 184 1.60 0.3E Desi as Maio Wind Force Resists System Ew-d Resisting - Low-rise and Components and Cladding -43L 3-4 .150 1.60 / 137 1.60 0.01 Tributary Area = 94 sgllt 4.5 .14E 1.60 / IM 1.60 O.II 5-6 / sea 1.as 0.38 - 8.7 •199(I.ES / 181 I.xS O.LS 7.8 •199(1.LS3/ 168 1.ES O. LS 8-9 -810((((1.253))/ Lai 91.60 0.18 9-10 -SBS 1.ZS / 110 91.60 O.LL IO.11 •65 1.60 / 455 I.ES 0.43 11-12 -14E I.Es / LN 1.25 0.+1 D. ISI iC aIQ. DUI. / TIX3.111172.1-11 w-14 -141 1.60 / 72891s 0.so 1+-13 -IEE 1.60 / 674. 0.29 15.16 •48 1.60 / Lea1.0.a7 16-17 -396 1. as / 109.O.Ea 17-18 -58E I.zs / 63 0.40 18.19 •1914 11.60 / L87l.0.ss 10-5-4 17-11-8 5-0-11 13-8-1 19-ZO 1.25 / 1061. 0.37 1 1 I ' 1 2 3 4 5 6 7 8 9 10 11 12 r .38E EO.21 -aa 91.25 / 931. 0.34 n a1v.(mn.>/ 7WIS. oua. col 10.00 10.00 -4.0 2.14 / E85 1.25 O.11. 2.15 :515034 SW (1,25 / EOS 1.60 0.07 4X10 3.15 -154(1.603/ 837 I.2S O.EB 3-16 -+19((1.x13/ 711.60 0.11 4X6 3X4 4X6 1.5X4 4-16 •zo3 91.93 / D.o9 sae / 556(1.25) 0.22 3X6 T s•u era l.xs / o.az 3X6 6 - -I+Is l.zs / s7 1.60 o.s2 6-1s -s 1.60 / Iarr l.zs o.52 5X6 7.18 -381 1.25 / 87 1.60 0.14 e -IB -SSL 1.25 / 10 1.60 0.1s 9-1-1 \7 sae -Iu 1.60 / sol 1.zs o.2+ 9-1 -15 9.19 •62+ 1.zs / z31 1.60 D.zz IO 1.60 / f0E8 I.Es 0.4E SHIP - -19 -911 lo•zo -loss I.zs / les 1.60 o.17 u-zo -414 Les / s, 1.60 0.07 �4M 4891-10 3X6 l 6X6 3X6 = 1.5X4 4X8 = 0-4-11 5X6 B2 4X10 5X8 3X4 B3 B4 0-3-13 _ B1 W:308 W:308 W:308 6.5 17-10-4 R:2445 38-8-4 R'1564 � R:-61 TqN A R:546 U: U:-139 R:546 U:�1 � U:-121 -6.50 _ J 0-�-6 8-8-8 4 29-5-0 1A -p 8-8-8 " 1;4;0 No. C 72160 47-1-8 13 14 1516 17 18 19 20 21 OVER 4 SUPPORTS CNI►. P 4�QF .0 AVFD All Connector plates are ALPINE Wave 20 ga., unless preceded by "H" for High Strength 20 ga., "S' for Super - Strength 18 ga. Plates are to be positioned per Joint Detail Report. Circled plates and false frame plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates. 5/6/2016 268 Homewoodross "WARNING!" READ AND FOLLOW ALL NOTES ON THIS DRAWINGI Cast: LEWIS WILLIAMS - (TCA) "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. DIB: Drive_lt_0220316_L000O7_j00001 W0: Drive_ll_0220316_L000 Trusses require extreme care in fabricating, handling, sNpl"ng, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and WTCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per SCSI. Unless Dsgnr: AW :ILC = 48 WT/PLY: 357 V V noted otherwise. top chord shall have property attached structural sheathing and bottom chord shall have a properly attached dgid ceiling. Locations shown have installed BC51 83, B7 870, Appy face truss TC Live 20.00 psf LiveDar L=1.25 P=1.25 n �� ^ n lt� for permanent lateral restraint of webs shall bracing par sections or as applicable. plates o each of and p_ lion as shown above and on the Joint Details report, unless noted otherwise. TC SnowP 0.00 psf (� SnowDar L=1.15 P=1.15 Il IIJj�\\IJP Alpine, a division of ITW Building Components Group Inc.. shall not be responsible for any deviation from this drawing, any failure to build the truss in TC Dead 14.00 psf Rep llbr End / Comp / Tens AN ITW COMPANY conformance with AN51/TPI 1, or for handling, shipping, installation 2 bracing of trusses. A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineering responsibility BC Live 0.00 psf 1.10 / 1.10 / 1.10 2820 N. Great SWPkwy. Grand Prairie, 7X 75050 solely for the design shown. The suitability and use of this drawing for any structure is the responsibility of the Building BC Dead 8.00 psf 0. C. Spacing 2- 0- 0 Designer per ANS1/rP1 1 Sec.2 THUSPLUS 6.0 VER: T6.5.20 For more information see this job's general notes page and these web sites: Bldg Cade: CBC -2013 DEFL RATIO: L/240 TC: L/24 gIPINE:wwvt-eloineiveom:TPI: wwwminstamtWfCAwwwsbcindusryem:ICC:wwwieesate.om Job Name: SINGLE FAMILY RESIDENCE Truss ID: A03A Qty: 1 BIG I-LOC REACT SIZE REQ'D TC 2x4 DFM. 81 t Btr.Well hraciug regmired at each location shows. This demip based on chord bracing applied 1 0- 1.12 533 3.50" 1.50" 1C 2z4 DFL 81 t Btr. ® IIefer to BCSI for proper repaired lateral per the 1•ollowing schedule: 2 17-10. 4 29393.50" 3.13" 2" DFL I2 17-18 restraint. For alternative web bracing, sax o.c. from to S 38- 8. 4 1712 3.50" 1.83" WEB 2x4 DFL STANDARD ase ITWBCG's standard details. TC 24.00" 10- S- 4 28- 4-12 4 46-11-12 353 3.50" 1.50" Fabrication Tolerance = 20.0% Designed per ANSI/TPI 1-2007 UPLIFT REACIION(S) : MA% DEFLECTION (span) Hcr (creep factor) - 2.00 Bearings designed for an FcPerrpp value of the Support CttC Wind Non-Wind L/852 HEN 20-21 (LIVE) LC 40 Refer to Joint QC Detail Sheets for lesser of the truss chord lumber value or 1 -124 Ib L= •0.12" D= -0.18" T= •0.29"Cq factors and Rotational Tolerances. 625 for all bearings. 2 -123 Ib __ )•Int L-tim - Loaded for 10 PSF mon-concurrent BOLL. IRC/11C truss plate values are based on S -72 Ib i o- o• 0 1x 47. 1. a Marls all interior hearing locations. testinngg a� approval as required by IBC 1703 4 -66 lb z v- a- 0 11 0- s• o Install Interiors rt(s) before erection. and ANSI/'ITI and are reported in ESII-1118. HOIIIZONIAI. IIEACIION(S) 3 9- 0. 0 l4 7. 3. 0 �� 4 10- 5- 4 13 e• t• 0 permanent bracing is wired to Dratmmgge shall be provided to avoid ponding. support 1 -255 lb S 14. 1-12 16 19- a- 4 proveat !station/toppling. See ILA. BASED ON GREEN LUMBER VALUES. support 4 -255 lb e 11-10- 4 17 17- e- a iCSI and ANSI/TPI 1. This truss is desimil ming the •---------LOAD CASE 81 DESIGN LOADS ---------------- 7 24- 1-11 le x4. 1.1z 20 psf Live Iniad applied to bottom chard In ASCE7-10 Wind Specification Dir L.PIf L.Loc Y.Pif R.toc LL/7L e 33 4.17 19 33- s- 7 IBC/IRC code provision. Bldg Enclosed = Yes, TC Vert 84.00 - 1- 0- 0 84.00 O. 0- 0 0.48 e z3- is 7 xo ae- e- 4 accardamce with 10 38- s- 4 Zl 47- 1- 8 Truss Location = Not End Zone TC Vert 68.00 O- 0- 0 68.00 47. 1- 8 0.59 l/ 40. S. 4 Category = C TC Vert 84.00 47- 1- 8 84.00 48. 1- 8 0:4 8 �Tt� MMER FORM' B 711 g Le h = BS.OB ft, Bldg Width = T2.33 ft 1C Vert 18.00 O- 0- 0 16.00 47. 1- 8 000 7C COIR. / 7®L3. 1St Mean r000fhei t 14.54 ft, h = 110 lbs H.Loc 11/76 Fastener 1-x -887 1.x5 / x01 1.60 0.40 height = .p Type E-3 -set 1.x5 / 186 1.60 0.36 OCrnpanry Category II, Dead Load = 15.2 psf TC Vert 0.0 0- 1-12 1.00 3.4 -103 1.60 / 179 1.60 0.01 De=igned as Malo Wind Force Resisting System TC Vert 0.0 46-I1-12 1.00 4.5 -101 1.60 / 155 1.60 0.1E - Lon-rise and Co neots and Cladding tC Vert BIS.O 21- 6-12 0.48 s-6 / 396 1.25 0.4E Tributary Area = 127 a ft s-7 •wi(1.xs/ 103 l.so o.ao �' sq ft •437}5(1.x5 / 103 l.So O.L7 8.9 -9x9 l.xs / xx6 1.60 0.19 9-10 -687 l.xs / 61 1.60 O.PA 10.11 •57 1.60 / 452 1.x1 0.49 11az -Iso 1.Its / E58 1.25 o.47 tte CBR. 1n. / rats. N. Cs 13-14 -148 1.60 / fi9.5 1.11. 0.14 14-1s -1E0 1.60 / 622 1.25 0.32 15-16 -64 1.60 / 264 1.60 0.20 16-17 -431 1.x5 / 101 1.60 O.ES 17-18 -585 1.25 / 66 1.60 0.7E 18-19 •38 1.60 / 446 1.25 0.76 10-5-4 I 17-11-8 I 5-0-11 I 13-8-1 19-20 -411 l.Es / as 1.80 0.32 20•x1 -x13 l.zs / el 1.25 0.42 1 2 3 4 5 6 7 8 9 10 11 12 Will coR.leua.M/ rals.0tm. C91 10.00 -10.00 4.0 x-14 / zu 1.25 O.11 2.15 -516 1.x5 / 209 1.80 0.07 3.15 -148 1.80 / 8x9 1.23 0.28 a-1e -ane 1.25 / Be 1,80 0.11 4X6 3X4 5X6 1.5X4 4X10 sae •x4x 1.x3 / 0.10 s-1fi / ", 1:601 0. as 3X6 T S•17 -7x8((1. x5)/ 0(1.80) O. E9 6.17-1109(1.Is)/ 0.61 3X6 6-1a / tes e 1.zs o.67 Tae -lee 1.zs / ez 1.60 0.14 5X6 9-1a -178 l.zs / 100 1.60 O.oa e-19 -179 1.S0 / 370 125 o.11 9 1 1 4X4 9-1 -15 9-1s -689 1.23 / 203 1.60 0.x4 6X 10 Is .25 1.as / 1153 1.23 0.47 1.5X4 SHIP to-zo -111e 1.25 / II1.60 0.18 4-8-10 11-zo •411 1.25 / 94' 1.60 0.07 3X6 1.5X4 1 4X8 3X6 = 0-4-11 81 7X16 B2 8X8 7X12 3X4 W: 0-3-13 / 308 W:308 W:308 B4 W: W:ri 6.5 1 33 7-10-4 R:2939 38-8-4 R:1712 W:308 Fy T. 533 QA/ U:U:-'j23 U:-72 R:353 0-R-8 6.50 613# 1 U:-66 J 8-8-8 29-5-0 1-o-0 6-6-6 1-0-0 No. C 72160 H 47-1-6 H 13 14 1516 17 18 19 20 21 r OVER 4 SUPPORTS CN11.. P q�OFCAUf All connector plates are ALPINE Wave 20 ga., unless preceded by "H' for High Strength 20 ga., "S" for Super Strength 18 ga. Plates are to be positioned per Joint Detail Report. Circled plates and false frame plates 5/6/2016 are posit as shown above. Shift gable stud plates to avoid overlap with structural plates. 268 - Homewoodrass **WARNING!** READ AND FOLLOW ALL NOTES ON THIS DRAWING! cost: LEWIS WILLIAMS ^ (CA) **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. DIB: Drive_M_O220316_L00007_j00001 v VTrusses require e7lreme cera in fabricating, handing, shipping, installing and bracing. Refer to and follow the latest edition of SCSI tBuildng Component W0: Drive_M_0220316_L000 Safely Information, by TPI end WTCA) for safsty practices prior to performing these functions. Installers,shall provide temporary bracing per BCSI. Unless Dsgnr: AW #LC = 48 WT/PLY: 373 to noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a property attached rigid ceiling. Locations shown t7 �0 r� T7 far permanent lateral restraint n webs shag have report installed per SCSI isefions 97, 87 or B10, as applicable. APMY plates to each face of truss and TC Live ( f 20.00 sf LiveSnowDor L=1.25 P=1.25 ILIL� � I �\ I I position as shown above and on the Joint Details report unless noted otherwise. TC SaaW P 0.00 psf SaowDaa' L=1.15 P=1.15 U v Alpine, a division of ITW Building Components Group Inc., shall not be responsible for any deviation from this drawing, any failure to build the truss in TC Dead 14.00 psf Rep Mbr Bad / Camp / Tens AN ITW COMPANY conform arca with ANSI/TPI 1, or for handling, shipping, installation 3 bracing of trusses. A seal on this drawing or cover page listing this drawing, Indicates acceptance o1 professional engineering responsibility BC Live 0.00 psf 1.00 / 1.00 / 1.00 2820 N. Great SWPkwy. Grand Prahfe, TX 75050 solely for the design shown. The suitability and use of this drawing for any structure Is the responsibility of the Building BC Dead 8.00 psf 0. C. Spacing 2- 0- 0 Designer per ANSI?PI f See.2 For more information see this job's general notes page and these web sites: THUSPLUS 6.0 VER: T6.5.20 ALPINE: wwwalolneiw.cem:;I:wwwtoinfi WTCAwwysbcntlustvoro:ICC: yooLkisatLM Bldg Code: CBC-2013 DBFL RATIO: L/240 TC: L/24 Job Name: SINGLE FAMILY RESIDENCE Truss ID: A04 Qty: , 1 1 BRG 1 -LOC REACT SIZE BEQ'D 1 0- 3- 8 1818 3.50" 1.94" 2 17-10- 4 2267 3.50" 2.42" 3 38-8- 4 1782 3.50 1.88" 4 46-11.12 1243 3.50" 1.50" MAX DEFLRffION (span) : L/868 MEN 15-16 (LIVE) LC 48 L= -0.28" D= -0.26" T= -0.54" �= Jalot lacatiaaa 1o• o• 0 10 46.11:12 z 7- 1- 4 11 0- o- 0 3 lo- 5• a 1z 7. 1. 4 4 17- t- 1 13 10- 3. 8 S 34. 0- 0 t4 17- 8.13 e a- s- a 15 z4. 0- 0 7 33- 3-11 16 33. 1-tt a 38- 6- a 17 u- a• s s 40. a- a 1s 46-11.12 TC CDM. 1Ut. / TIXS. 081. Csi 1.2 -2671 1.60 / tele 1.80 0.04 z-3 -lose 1.60 / 1237 l.so 0.32 3-0 •1577 1.80 / 1679 1.60 0.36 4-5 •123a 1.6D / 3•s •1404 1.60 / 676 1.60 0.41' 1042 1.60 0.21 4.7 -2531 1.60 / 1761 1.60 0.24 7-8 •2718 1.80 / 2153 1.60 0.27 e -e •23sz 1.60 / e-10 •2147 1.6o / 2101 1.60 nose zees 1.80 o.so aC COM. IR. / T@6. ID. 6I is •4161 1.60 / 4655 1.60 0.78 :41 12-13 -4148 1 so / 13.14 -3971 loan / 4851 1.60 0.45 4191 1.60 ooze 14.15 •3338 1.60 / 3457 1.60 O.SI 13-16 -2746 1.60 / 3140 1.60 0.68 le -t7 -4215 I.80 / 17-18 -3211 1.60 / 3831 1.60 0.48 silo 1.se 0.64 11 COM. IR. / TENS. DUB. CSI z-12 •zea 1.60 / 437 1.60 0.15 2-13 •977 1.Go / 3-13 -310 1.60 / b90 1.60 0.78 661 1.25 0.41 3-14 -22241.60 / 1576 1.60 0.94 4-14 .1358 1.23 / 576 1.60 0.59 4. 5-1515 x -881716 1. 1.8023 / / 176Eel 1. 1.6060 o. 0.500:5146 6-13 •Luz 1.60 / 1107 1.60 0.36 6.16 -797 1.60 / 1111 1.80 0.48 7.18 -731 1.23 / 8.16 -611 1.80 / ETO 1.60 He 1857 1.60 0.53 8.11 •1123 1.25 / 314 1.60 0.20 9.17 •567 1.60,/ 225 1.60 0.09 TC 234 DFL 81 i Stir. K 2x4 DFL 41 a Stir. 266 DFL SS 11.14 WEB 2x4 DFL STANDARD PLT BLB 2x4 DPL 41 A Btr. Bearings designed for an FcPerrpp value of the lesser of the truss chord Immher value or 625 for all bearings. IRC/IRC truss plate values are based on testing and approval as required by IRC 1703 and ANSI/TPI and are reported in R-1118. Drainage shall be provided to avoid preading. + + + + + + + + + + + + + + + + + + + + + + Desiggnmeed for 6.3 E lbs drag load applied horluatally in either direction to the top chord panel pints, with dead + 0 % live loads wing load duration = 1.60. Horizontal reaction = 6.3 R lbs at each bearing individually. Connection by others. + + + + + + + + + + + + + + + + + + + + + + 20 psf Live Lead applied to bottom chord in accordance with IBC/IRC code provisions. ®Web broctag regaired at each location shown. Refer to BCSI far proper regained lateral restraint. For alternative web bracing, OnITWBCG's standard details. Designed per ANSI/'IPI 1.2007 Fabrication Tolerance = 20.0% Err (creep factor) = 2.00 Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. Loaded for 10 FSF Hoa -concurrent SCLL. No all interior heartnagg locations. Install interior supper t(s) before erection. PLAYING RASED ON GREEN LUMBER VALUES. This Ireton is designed using the ASCET-10 Wind Specification Bldg Enclosed = Yea, Trona Location = Not Pad Zane Hr� Category = C 3 dl g Length - 65.08 ft, Bldg Width = 72.33 £t Mesa roof height = 14.54 ft, yb = 110 Occupancy Category II, Dead Load = 13.2 psf Designed ns Hain Wled Force Resistin11gg Syntex Low-riae and Components and Claddlmg Tributary Area = 94 sgft 10-3-8 M 17-11-8 t 5-0-11 M 13-8-1 1 2 3 4 5 6 7 8 9 10 10.00 3X6 5X8 5X8 10.0 4.0 1.5X4 4X4 3X8 This design based on chord bracing applied per the following schedule: naz o.c-from to TC 24.00" 10. S. 4 28- 4-12 UPLIFT REACIION(S) : Support CIC Wind Non -Wind 1 .52 lb .1101 Ib 2 -55 16 -119 Ib 3 -107 1b 4 -60 lb -846 Ib HORIZONTAL REACTIONS) support 1 .6300 Ib support 2 6300 lb support 3 -6300 Ib support 4 6300 Its OVER 4 SUPPORTS All connector plates are ALPINE Wave 20 ga., unless preceded by "H" for High Sirength 20 ga., "S" for Super Strength 18 go. Plates are to be positioned per Joint Detail Report. Circled plates and to frame plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates. 9 4-15 SHIP 268 - Homewoodruss **WARNING!** READ AND FOLLOW ALL NOTES ON THIS DRAWING! Cast: LEWIS WILLL4MS (TCA) **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. 0-6-2 rr 1.5X4 7X10 B2 5X8 6X8 7X10 0-3-13 Safely Information, by TPI and TCA) tot safety practices prior to performing these functions. Insteiers shall provide temporary bracing per BC51. Unless W B1 3X4 W:308 B3 84 LiveSnowDar L=1.25 P=1.25 W:308 17-8-8 R:2267 38-6-8 W:308 W:308 R:1816 U:-119 R:1762 R:1243 conformance with ANSI/TPI 1, or for handling, shipping, installation a bracing of trusses. A seal on this drsw/ng or cover page listing this drawing, Indicates acceptance of professional engineering responsibility U:-1101 1.10 / 1.10 / 1.10 U:-107 U:-846 BC Dead 8.00 psf 0. C. Spacing 2- 0- 0 46-11-12 Designerper ANSI/TPI t Sec.2 1.0:0 0.1-12 TRUSPLUS 6.0 VER: T6.5.20 46-11-12 Bldg Code: CBC -2013 DEFL RATIO: L/240 TC: L/24 STUB 11 12 13 14 15 16 17 18 OVER 4 SUPPORTS All connector plates are ALPINE Wave 20 ga., unless preceded by "H" for High Sirength 20 ga., "S" for Super Strength 18 go. Plates are to be positioned per Joint Detail Report. Circled plates and to frame plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates. 9 4-15 SHIP 268 - Homewoodruss **WARNING!** READ AND FOLLOW ALL NOTES ON THIS DRAWING! Cast: LEWIS WILLL4MS (TCA) **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. DIB: Drive_M_0220316_L00007rj00001 Trusses re4uire extreme care in lebriceting, handing, snipping, installing and bracing, Refer to and follow the latest edition of BCSI (Building Component W0: Drive_M_0220316_L000 Safely Information, by TPI and TCA) tot safety practices prior to performing these functions. Insteiers shall provide temporary bracing per BC51. Unless W Dsgnr: AW :ILC = 56 WF/PLY: 369 v V iN noted otherwise. top chord shell have properly attached structural sheathing and bottom chord shall have a property attache, dpd calling. Locations shown Apply to lace truss TC Live 20.00 psf LiveSnowDar L=1.25 P=1.25 ^ n lu�\vl I ALM for permanent lateral restraint n webs shag have report, installed per Cher sections, 83,87 or BID, as applicable. plates each of and position as shown above entl on the !Dint Details report, uNess noted otherwise. TC Snout(Pf) 0.00 psf SuowDnr L=1.15 P=1.15 Alpine. ad Nision of ITW Building Components Group Inc.. shall not be responsible for any deviation from this drawing, any failure to build the truss in TC Dead 14.00 psf Rep Mhr Bad / Comp / Tens AN /TW COMPANY conformance with ANSI/TPI 1, or for handling, shipping, installation a bracing of trusses. A seal on this drsw/ng or cover page listing this drawing, Indicates acceptance of professional engineering responsibility BC Live 0.00 psf 1.10 / 1.10 / 1.10 2820 N. Groat SIN Pkwy. Grand Prairie, TX 75050 solely for the design shown. The suitability and use of this drawing for any structure Is the responsibility of the Building BC Dead 8.00 psf 0. C. Spacing 2- 0- 0 Designerper ANSI/TPI t Sec.2 TRUSPLUS 6.0 VER: T6.5.20 For more information see this job's general notes page these web sites: gIPiNEtwyvyalpineiweemtTPl:wwwto"nsrom'VJTCAwvnvsbeintlustvom'ICC:wwwlccsafa.orp Bldg Code: CBC -2013 DEFL RATIO: L/240 TC: L/24 Job Name: SINGLE FAMILY RESIDENCE Truss ID: A05 Qty: 3 BRG I -LOC REACT SIZE RBQ'D TC 2z4 DFL Pl t Stir. Web bracts( required at each location shown. DIB: Drive_M_0220318_L00007rJ00001 This design based on chord bracing applied following 1 0- 3• B 1412 3.50" I.S1" 2 38- 8. 4 3188 3.50" 3.41" RC, 2z8 DFL 82 ® 2x4 DFL 41 4 Rtr. 12 -IS, 15-17 Refer to ICSI for proper required lateral restraint. For alternative web bracing, SafetyInformation, by TPI and WTCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless per the sdmdole: max O.C. from to 3 46-11.12 3 3.50" 1.50" WEB 2z4 DFL STANDARDBee ITWBCG's standard details. LivelhSnoufar L=1.25 P=1.25 TC 24.00" 10- S. 4 28- 4-12 MAX D - DEFLECTION (span) 2x4 DFL 91 ► Stir. 3-15, I5 -S Designed per ANSI/TPI 1-2007 fl UPLIFT REACTION(S) : L/999 IDEM 4.5 (LIVE)LC 42 19-9 Fabrication Tolerance = 20.0% conformance with ANSIrrPi 1, or for handling, shipping, installation 8 bracing of trusses. A seal on this drawing or cover page listing this drawling, Indicates acceptance of professional engineering responsibility Support CIC Wind Non -Wind ' L= .0.42" Do -0.91" To -1.33" WEDGE 2n8 DPI. 42 Bearings designed for an FcPerp value of the BC Dead 8.00 psf 1 -92 lb lb - )•let L. -ti -m Rcr (cm factor) = 2.00 lesser of the truss chord ]amber valve or 2 .105 I D- o• 0 12 e• o. 0 Refer to Joint QC Detall Sheets for 925 for all bearings. 3 -449 Ih -715 Ib 2 7- 1- a IS 7- l• 4 Cq factors and Rotational Tolerances. IRC/IRC tress plate values are based an HORIZONTAL RBACTION(S) a 10- 3- a 14 10. 3. 8 4 Ill- a- 8 Is la 4. 4 Loaded for 10 PSF mon-concurrent BCL2.. testi and approval u required b IBC 1703 ng PP re9n support 1 -234 Ib uFPa 3 1► s l7- s- 8 is I7- a• a 6 a4- a-12 17 24. 6•la 7 as. a• 0 18 28. 3- o Mark all interior bearing locations. + + + + + + + + + + + + + + + + + + + + + + " and ANSI/TPI and are reported in R-1118. Install interior support(s) before erection. support -234 76is truss is designed using the ASCET-10 Wind Specification 8 ss• 3-11 /e aa• a. Unrestrained boriz. LL deflection = 0.39 Draimge shall be provided to avoid ponding. PLATING BASED ON OMEN LUMBER VALUES. Bldg Enclosed = Yee, 9 38- a- a EO 38. 6- 8 a 10 40- a- 8 21 4a -11-t2 + + + + + + + + + + + + + + + + + + + + + + Not designed for attic storage ®leas Dae tohigh uplift reaction, this trOBs details Truss Location Not End Zone Category C 11 4a-11-12 CILMCAL X0101 FORCM noted otherwise. regwires a Lal ennnection (designed by others) to secure tress = R11 g Length - 65.08 ft, Bldg Width = 72.33 ft Te 001P. 261. / TINS. DIM. rsi to a rigidly anchored support. 8 y PPo Meem rwf het t 14.54 ft, ■ h = 110 gb = 1•z •s4so 1.zs / ue L60 0.59 2-3 -4046 1.23 / 105 1.60 o.at Occupancy Category II, Dead Load = 13.2 psf 3.4 .5078 l.as / 52 1.60 o.so 4-5 1.25 / 32 1.60 0.14 Designed as Malo ®tad Force Resisting System Components Cladding -5078 3.8 •2227 1.25 / 261 1.80 0.40 -law-rise sad and Tributary Area = N Bgft 0.7 •1074 1.25 / El5 1.80 0.24 7.8 .1083 1.25 / 215 1.60 0.2E 8-9 -69 1.60 / 252 1.60 0.28 B•IO -1 1.80 / 3070 1.25 0.66 10.11 .11 2.60 / 2972 I. 0.63 3C co". am. / 11NS.ID17. 61IL-tl -105 1.80 / 278515 0.59 13-14 eo 1.e0 / a7e41.23 0.59 14•IS/ 34531.as0.44 111 / 27591.23 0.4616-17 / 1281I.1S0.34 17-i8 / 7271.zs OAS 1e -ie -122(1.80)/ 17-11-8 5-0-11 13-8-1 471zs0.0910-3-8 19-zo -2797 I-LS3/ 471.80O. aL zo•zl •2754 1.25 / 7i.an 0.38 1 2 3 4 5 6 7 8 9 10 11 R1 001f.(DOT. / TENS. DUI. OSI 2.13 •8(1.233/ TIO 1.23 0.04 10.00 _10.0 -4.0 2-14 -408((1.803/ 241 1.80 0.08 3•u •lz4 1.60 / 297 1.25 0.12 1.5X4 4X10 3.15 / 2840 1.zs o.ss 4 -as -73(1.23)/ 92 1.60 0.03 H0710 3X8 5X8 5 -IS / allf 1.25 0.38 5.18 •2348(1.23)/ u 2.80 0.69 1554 1.25 0.63 3X6 6.11 •1333 1.23 / w 1.eo 6.47 7.17 I8 1.50 / 871 1.zs o.as 7.18 -463 I.z3 / o.ls e-le / e73 1.zs O.3s 8-i9 •1558((1.25 / 89 1.60 O.SE 9.1_1 4X >56X8 9 4 15 9.19 -69(2.803/ aloz 1.zs o.s9 I 6_ _6 1.5X4 1.5X4 SHIP 9 -Eo .2724C(1.zs to-zo -Iso 1.zs / ui 1.60 o.az / 99 1.so o.ae 4X10 SS0612 3X10 111 I 4X6 x 0-6-2 3X8 7X8 3X4 8X10 3X4 B2 B3 0-3-13 _ W:308 W:308 P� Bi 6.5 6.50 38 6-8 105 T• W:308 0-1;12 U:-1 : 715 U:-71596 R:1412 12-2-8 U:-82 12-2-8 100 x1-12 46-11-12 STUB 12 13 14 15 16 17 18 19 20 21 No. C 72180 C(V14 P PF CAUV All connector plates are ALPINE Wave 20 ga., unless preceded by "H' for High Strength 20 pa., "S" for Super Strength 18 go. Plates are to be positioned per Joint Detail Report. Circled plates and false frame plates 5/6/2016 are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates. 268 Homewood **WARNING!*" READ AND FOLLOW ALL NOTES ON THIS DRAWING! Cast: LEWIS WILLIAMS - toss (CAS **IMPORTANT"'* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. DIB: Drive_M_0220318_L00007rJ00001 Trusses require ertreme care in rabricating, isshipping, installing and bracing. Refer to and follow the latest edition of SCSI (Buildna Component Wil: Drive_M_0220318_L000 SafetyInformation, by TPI and WTCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless Dsgor: AW :ILC = 42 Wf /PLY: 382 iV noted otherwise, tap chord shall have property attached structural sheathing and bottom chord shall have a property attached rigid ceiling. Locations shown TC Live 20.00 psf LivelhSnoufar L=1.25 P=1.25 r� rt � 1�^\\V\IJII /�/ ALM a 83, B7 or 810, as applicable. Apply plain to each face of truss and for permanent shown a restraint n webs shell have bracing edeas tl per BCSI otherwise. position as shown amus and on the Joint Details report uNess noted oNerwise. TC Snout(Pf) 0.00 psf SaoNDar L=1.15 P=1.15 fl Alpine, a division of ITW Building Components Group Inc., shall not be responsible for any deviation from this drawing, any failure to build the truss in TC Dead 14.00 psf Rep Mbr End / Comp / Tens AN ITW COMPANY conformance with ANSIrrPi 1, or for handling, shipping, installation 8 bracing of trusses. A seal on this drawing or cover page listing this drawling, Indicates acceptance of professional engineering responsibility BC Live 0.00 psf 1.10 / 1.10 / 1.10. 2820 N. Great SWPAwy. Grand Prairie, 7X 75050 solely for the design shown. The suitability and use of this drawing for any structure Is the responsibility of the Building BC Dead 8.00 psf 0. C. Spacing 2- 0- 0 DesignerperANSI/TPI 1 Sec.2 TRUSPLUS 6.0 VEE: TB.S.ZO For more information see this job's general notes page and Nese web sites: ALPINE: www aloineitwcam :TPLwww toinstora WTCA: wwwsbcindustryore, ICC: www ieesefenm Bldg Code: CBC -2013 -' - DEFL RATIO: L/240 TC: L/24 Job Name: SINGLE FAMILY RESIDENCE Truss ID: A06 Qty: 11 BIG 1 -LOC REACT IZ SE REQ ;D 1 0- 3. 8 1412 3.50" 1.51" 2 32-10- 4 1600 3.50" 1.71" MAX DM CTION (sppgn) ! L/887 ME4-5 (LIVB)•LC 42 L=-0.40" D= .0.80" T= -1.20" EX.WE DEP CRITERIA:L/120 IN 1®1 IS- 8; T= 0.08" _= Jrdat 1 -ti- e 1 0• 0• 0 B 0- 0- 0 z 7. 1• a l0 7- 1- 4 3 to. 3. 8 11 ID- 3• s 4 12. 2. 8 12 I8- 4- 1 s 17. 8. 8 13 v e- 8 e a 8.12 a E4- 6-/E 7 ES• 3. 0 13 32-10- 4 8 ]E•10. 4 CRITICAL emus FORM: TC COtr. DTR. / Tm6. DOB. CSI 1•L -4430 1.25 / 597 1.60 O.SB 2-3 -4046 1.25 / SSB 1.60 0.91 3.4 •3078 1.25 / an 1.60 o.ae 4-5 -5078 1.25 / 682 1,60 0.76 5.8 •'325 1.2.5 / E49 1.60 0.41 B-7 •108t 1.25 / 165 1.60 O.ES 7-8 -208 I.80 / LLB 1..0 O.Ee K C08r. DOB. / TENS. R. CSI B -IO •787 1.60 / ]785 1.25 0.58 t0 -ll -7EE 1.60 / 3784 1.25 0.59 11 -IE -530 1.80 / ]454 1.25 0.44 I2-13 •a5L 1.80 / EJso 1.25 0.44 13./4 •IB4 1.80 / ILBt I.ES 0.33 14 Is •143 1.60 / 686 1.25 0.49 Bl011110t.1R. / TENS. CSI 2-1 0 .124.60 / 114 1.25 0.05 E-11 -4E0 1.60 / JAS 1.80 0.08 3.// -lE5 1,80 / 'M 1.25 O.1L 3.12 -313Z4'1.60 / 2842 1.25 0.36 4-12 -76 1.zs / 97 1.80 0.03 5 -IE -433 1.60 / 2877 1.Es 0.37 5-13 -14514 I.zs / 238 1.60 0.69 s -I3 -162 1.60 / 1543 1.25 0.63 6.14 .1291 1.z5 / 184 1.60 0.46 7-14 -26 1.60 / 1037 1.11 0.42 7-145 -1410 Lzs / 137 1.60 0.61 8-15 -234 1.60 / ISO 1.60 0.48 TC 2x4 DPL #1 D Btr. BC 2x4 DPL' #1 6 Btr. 2x6 DPL #2 14.15 WEB 2x4 DPL STANDARD 2x4 DPL 01 D Btr. 3-12, 12-5 WEDGE 2.6 DPL #2 Ker (creep factor) = 2.00 Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. Loaded for 10 PSP mon-cencurrent BCLL. ............... ...... . Unrestrained horiz. LL deflection = 0.40 " .... .... ..... . .. . . . . . . End verticals are designed for axial loads only, "less noted otherwise. 9-1-1 2 4X10 0-6-2 B1 ®Web bractag required at each location shown. Be fer to BCSI for proper required loteral restraint. For alternative web bracing, see rrWRCG's standard details. Desiggnnedper ANSI/TPI 1-2007 Fabrication Tolerance = 20.0% Bearings designed for an PcPerp value of the lesser of the truss chord lumber value or 625 for all bearings. IHC/IBC truss plate values are based on testingland approval as required by IBC 1703 and AN and are reported in SSB -Ills. Drat a shall be provided to avoid pending. PIATlIi� tASBD ON GREEN LUBBER VALUES. 20 paf Live Load aappplied to bottom chord in accordance with IBC/IBC code previsions. 10-3-8 17-11-84-7 4 11 2 13 4 5 6 Y7 8' 10.00 1.5X3 10.0 5X This design based on chord bracing applied per the following schedule: sax o.c. from to TC 24.00" 10. 5- 4 28- 4-12 UPLIFT REACTION(S) : Support CDC Wind Non -Wind 1 .71 Ib 2 -99 lb HORIZONTAL REACTION(S) support 1 284 Ib support 2 294 lb This truss is designed using the ASCET-10 Wind Specification Bldg Enclosed = Yes, Truss &mention = Not End Zoete ..ICategory = C s Length = 65.08 ft, Bldg Width = 72.33 ft tleam roof height = 14.54 ft, ■!b = 110 Occupancy Categgory II, Dead Load = 13.2 psf Designed as No It ®ind pores Resisting System Low-rise and Components and Cladding Tributary Area = 66 sqft Vertical members exposed to wind: 1S- 8 1.5X3 9-1-1 SHIP 5-3-0 1 B2 6 %At inn W:308 6.5 -6.50 R: 600 R:1412 0-112 U:-71 i 12-2-8 -� I 8-3-8 i U:-99 12-2-8 0-1-12 32-10.4 114-1-8 STUB 9 10 11 12 13 14 15 -STUB All connector plates are ALPINE Wave 20 ga., unless preceded by "H" for High Strength 20 ga., "S" for Super • - Strength 18 ga. Plates are to be positioned per Joint Detail Report. Circled pYates and false frame plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates. 5/6/2016 268 - Homewood Truss "WARNING!" READ AND FOLLOWALL NOTES ON THIS DRAWING! "IMPORTANT' Cast: LEWIS WILLI MS DIB: Drive_ M_ 0220316_1,00007J00001 (CA) FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. ^ Trses reQuira extreme care in lebricating, handling, shipping, inttalling and bracing. Refer to and follow the latest edition of SCSI (Buildng Component W0: Drive0220316_L000 Safusety Information, by TPI and WfCA) for safety practices prior to performing these functions. Instaflers shall provide temporary bracing per BCSI. Unless Dsgnr: AW #LC = 46 Wr/PLY: 265 v V rs noted otherwise, top chord shall have propery, attached structural sheathing and bottom chord shall have a property attached raid ceiling. Locations shown tete TC Live 20.00 ppsf LiveSnowDar L=1.25 P=1.25 O I �\ I I ��� n r7 for permanent lateral restraint n webs shall have bracing instilled per Cher ise. rre B3,137 or 810, as applicable. APPN plates to each of truss and position as shown above end on the Joint Details report unless noted otherwise. TC Snow(PF) 0.00 sf ( F) SaowDar L=1.15 P=1.15 U v Alpine, a division of ITW Building Components Group Inc.. shag not be responsible tot any deviation from this drawing. any failure W build the truss in TC Dead 14.00 paf Rep ifbr Bad / Comp / Teas AN /TW COMPANY conformance with ANSIrTPI 1, or for handling, shipping, Installation L bracing of trusses. A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineering responsibility BC Live 0.00 paf 1.10 / 1.10 / 1.10 2820 N. Great SW Pkwy. Grand Pralds, TX 76050 solely for the design shown. The suitability and use of this drawing for any structure Is the responsibility of the Building BC Dead 8.00 prof O. C. Sparcing Z- 0- 0 DesignerperANSI?PIT Sec.2 TRUSPLUS 6.0 VSO: T6.5.20 For mora information see Nis job's general notes page and these web sites! ALPINE: www alsinsimcorn TPI: wwwminstsra WTCA-lac'nduaMora-ICC:wvnvicsafsoro Bldg Cade: CRC-ZO13 DEPL RATIO: L/Z40 TC: L/24 [Job Name: SINGLE FAMILY RESIDENCE Truss ID: AOG Qty: 1 I BRIG R -LOC REACT SIZE REQ'D 1 0- 3- 8 264 3.50" 1.50" 2 1- 2- 4 113 5.50" 1.50" 3 2- 2.12 154 3.50 1.50" 4 3- 6.12 1583.50" 1.50" 5 4-10-12 176 3.50" 1.50" 6 6- 2.12 ISO 3.50" 1.50" 7 7- 6-12 2013.50" 1.50" 8 8-10-12 252 3.50" 1.50" 9 10- 2-12 165 3.50" 1.50" 1011- 6-12 291 3.50" 1.50" 11 12-10-12 254 3.50" 1.50" 12 14- 2-12 283 3.S0 1.50" 13 1S. 6.12 260 3.50" 1.50" 14 a8-10-12 360 3.50" 1.50" 15 IS- 2-12 237 3.50" 150" 16 19- 6-12 377 3.50" 1..50" 17 20.10-12 340S.SO" 1.50" 18 22- 2.12 303 3.50" 1.50" 19 23- 6.12 294 3.50" 1.50" 20 24-10.12 290 3.50" I.SO" 21 26- 2-12 284 3.50" 1.50" 22 27- 6.12 248 3.50" 1.50" 23 28-10.12 236 3.50" 1.50" 24 30- 2.12 220 3.50" 1.50" 25 31- 6.12 292 3.50" 1.50" 26 32-10. 4 169 3.50" 1.50" MAX DEFLECTION (span) : L/999 MEN 14-15 (LIVE) LC 1 L= 0.00" D= .0.01" T= -0.01" EX DEF CRTTERML/120 IN Im 51-26; T= 0.07" Tc 1•E COEP. OUR. / TENS. BUR. CSI •259 1.60 / 206 1.60 0.04 L-3 •2E8 1.60 / 178 1.80 0.04 3.4 -208 I.so / .99 I.60 0.03 4.5 s-6 187 1.60 / -165 1. so / las 1.60 0.03 142 1.60 0.03 6.7.158 1.60 / .74 1.60 0.01 7.6 •209 I.so / L0s 1.60 0.01 s-9 e 10 -150 1.60 / -150 1.60 / leo 1.60 0.04 les 1.60 0.04 10-11 -Iso 1.60 / Iso 1.60 0.04 11-1L la.11 -150 1.60 / -Iso 1.80 / .180 Ise 1.60 0.04 1.80 o.os 13-14 -Iso l.so / Iso 1.80 a.as 14-I5 -150 1.60 / leo 1.60 0.06 I5-16 16-17 -148 1.60 / -148 1.60 / lel 1.60 0.06 161 1.60 0.05 17-18 -148 1.60 / 191 1.60 0.04 IB -IB 18 -ail -148 1.60 / -148 1.60 / 161 1.80 0.04 161 1.60 0.04 20•at -148 1.60 / 161 1.60 0.05 L1 -EE 22-E3 -148 1.61) / -175 1.60 / 181 1.80 0.05 153 1.60 0.05 13.24 •193 l.So / x08 1.60 0.06 24.251 LS -EB •14 l.so / -101 l((.DDso /)) 148 1.60 0.04 103 1.(60 0.))03 3x8 c?"'OX 27CSI 60)/ 103(1 60) 063 28.33 / 0.01 33 -34314 4-35 0(1.25)/ O(1.60) 0.04 35-36 39.37 / a 0 37.38 / 0.01 38.39 / 0.02 39-ao / 0.x6 40.41 / 0.06 41-S1 / 0.01 WE Colo. DUB. / TENS. DUB. CSI z-28 -14a Las / 60 1.60 0.0z 3-E9 .136 1.2s / 28 1.60 0.Oz 4 -So las 1.x5 / a7 1.60 0.05 5.31 -169 1.x5 / 21 1.80 0.08 6.32 -178 1.25 / 19 1.80 0.12 7.33 245 1.25 / 0.24 8.34 174 1.x51 / z(l.ao) o.os e-35 x19 1.25 / 0.008 10.18 -E42 1.25 / 0.09 11.37 12.38 -260 1.25 / -270 1.25 / 0.08 0.10 TC 2x4 DFL #14 Btr. BC 2x4 DFL #1 A ltr. WEB 2x4 DFL STANDARD WEDGE 2x0 DFL #2 Fabrication Tolerance = 20.0% Rcr (creep factor) = 2.00 Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. Loaded for 10 PSF eon-coucarrent ICU. Mark all Interior bearsagg I catioan. Install interior supports) before erection Permanent bracing is required to !revent rotation/toppling. See CSI and ANSI/TPI 1. PLATING BASED ON GREENY LUIUIEt VALUES. Pad verticals are designed for axial loads onlyy� mnless noted otherwise. BOHIZONTAL REACTIONS) support 1 117 6 support 2 -106 16 Nat dea�gguned for attic storage unless noted at cruise. YB COEP. DLR. / TENS.(DUR.) CSI 13-39 -274 1.25 / 0.10 14-40 453 1.25 / 0.09 15.41 •375 1. IS / 0.14 18.12 -917 1.25 / O.12 17.451 2ez 1.x5 / o.Io 19.44 -E72 1.25 / 0.10 19-451 x519 ..Z5 / 0.09 20.49 -E42 I.2S / 0.09 x1.47 zz7 1.x5 / 0.09 23.98 -214 1.as / 0.07 24.49 -188 1.25 / 22(1.80) 0.18 25-50 •199 L 25 / 1S . 60 00.13 26.50 -134 1.80 / 182 1.60 to 2s -sl 134 1.25 / a8 t.so 00.47 IE 0-6-2 4X6 ®Web bracing repaired at each location shown. Refer to iCSI for proper required lateral restraint. For alternative web bracing, see ITWBCGts standard details. Designed per ANSI/TPI 1-2007 Bearings designed for on FcPerp value of the leaser of the truss chord lumber value or 625 for all bearings. IHC/IBC truss plate -toes are based on testing and approval as required by INC 1703 and AN and are reported in ESR -1118. Drainage shall be provided to avoid pa Wag. Building designer shall verify gable Ioads and eave leads, if applicable. 1+1 gaaxpbpoole bract reqquuired 0 42" intervals, if seeeTiWBCG Iso wfad Gable Bracing Details. to This truss is designed using the ASCE7-10 Wind Specification Bldg Enclosed = Yes, Truss Mention = Not End Zone MCategory = C )1 g Length = 65.08 ft, Bldg Width = 72.33 ft Me" roo Meheight = 14.54 ft, aph = 110 Occupancy Category II, Dead Load = 13.2 psf Designed " Rain Wind Force Hesistiag Syatea Low -rime and Co onents and Cladding Tributary Area = 144 sgft Vertical members exposed to wind: 51-26 1 2 3 4 5 6 7 8 9 10 11 12 1314 15 16 17 18 19 20 2 223 24 26 10.00 -10.0 This design based on chord bracing applied per the f-ollowing schedule: aux o.c. from to TC 24.00" 10- 5- 4 28- 4-12 UPLIFT REACTION(S) Support CBC Wind Non -Wind 1 .42 Ib 2 -91 16 3 •27 ib 4 -13 16 S .10 Ib 8 -7 Ib 7 •8Ib 8 10 16 9 .6 16 10 .12 Ib 11 -10 16 12 .11 16 13 -ll 16 14 -14 16 IS -9 16 16 -I5 16 17 -14 Ib 18 -12 16 19 -12 lb 20 .1/ Ib 21 -10 Ib 22 •10 lb 23 -9 16 24 -9 Ib 25 -v5 16 III -26 16 Truss designed to support 1-0-0 top chord outloolters and cladding load not to exceed 10 PSP one face, and 24" span opposite face. Top chord must not be cot or notched. 2.5X4- - - - 0-1-12 32-10-4 114 1-8 STUB 27 28 29 30 31-32 33 3435 36 37 38 3940 41 42 43 44 45 46 47 48 49 50 STUB TYPICAL PLATE: 1.5X3 - OVER SUPPORT AS SHOWN ,4�SyFv. T. J No. C 72160 CAUV All connector plates are ALPINE Wave 20 ga., unless preceded by "H' for High Strength 20 pa., "S" for Super-- -- •-- - - x -k-. _ `� - - Strength 18 ga. Plates are to be positioned per Joint Detail Report Circled plates and false frame plates 5/6/2016 are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates. 268 - Homewoodruss "WARNING!`* READ AND FOLLOW ALL NOTES ON THIS DRAWING! Cast: LEWIS WILLIAMS (CA) "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. DIB: Drive_M_0220316_L00007_j00001 Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Builsng Component WO: Drive_M_0220316_L000 Safety Information, by TPI and WTCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless Dsgnr: AW #LC = 43 WI/PLY: 445 V V pa noted otherwise, top chord shall have property attached structural sheathing and bottom chord shall have a property attached rigid ceiling. Locations shown 810, face TC Live- 20.00 psf Liveur L=1.25 P=1.25 D /'� Al� � for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3. B7 or as applicable. Apply plates to each of truss and position as shown above and on the Joint Details report unless noted otherwise. TC Snout P 0.00 psf ( Snowl ur L=1.15 P=1.15 Alpine, a division of ITN Building Components Group Inc., shall not be responsible for any deviation from this drawing, any failure to build the truss in TC Dead14.00 psf Rep Mbr Rod / Comp / Tens AN /TW COMPANY conformance with ANSI/7PI 1, or for handling. shipping, installation a bracing of trusses. A sea) on this drawing or cover page listing this drawing, Indicates acceptance of professional engineering responsibility BC Live 0.00 pair 1.00 / 1.00 / 1.00 2820 N. Groat SW Pkwy. Grand Prafrfa, TX 75050 solely for the design shown. The suitability and use of this drawing for any structure is the responsibility of the Building BC Dead 8.00 psf 0. C. Spacing 2- 0- 0 Designer per ANSI/rP1 f Seat TRUSPLUS 6.0. VER: 76.5.20 For more information see this job's general notes page and these web sites: ALPINE: wwwatoneivcom TPI: mmo tonsturn:WrCAwwwabnntl-y�nrg.ICC:nomEacsafnnrn Bldg Code: CRC -2013 DBFL RATIO: L/240 TC: L/24 Job Name: SINGLE FAMILY RESIDENCE BRG X_ LOCBRACT SLZE BEQ'D TC 2z4 DPL S1 4 Btr. 1 0- S-12 988 3.50" 1.50" BC 2z4 DFL 141 B Btr. 2 17- 1-14 967 3.50" 1. SO" WEB 2z4 DFL STANDARD MAX DEMATION (sger L/999 MEM 4-5 (an )•LC 64 (creep factor) = 2.00 Refer to Joint QC Detail Sheets for L= -0.20" D= -0.27" T= .0.47"Cq tLetors and Rotational Tolerances. Jelat 1-1:11- a i o- 0- 0 6 e- 0• o Leaded for 10 PSP non-rnntorrent BOLL. PLATING BASED ON GREEN LUMBER VALUES. 2 s• 7 4- o• 0 20 psf Live Load applied to bottom chord in 3 4• .0-.0.- a s- 0-13 4 11.1-10 9 11. 1-10 accordmace with IBC/IRC code provisional. S- 17. 7-/0 10 17- 7-10 OB: CRITICAL KEOU iC85 TC CORP. 1-z •IOlB 1.25 / 89 1.00 0.48 2-3 -875 1.Ls / 180 L80 0.71 3-4 -875 IAS / ISO 1.60 0.71 4.5 -1018 1.25 / 69 1.60 0.48 BC COBr.(8U8.)/ TOis. v V ry -7 1.200.48 101111,)t5IT - 86831.LS .8.8 LiowDor L=1.25 P=1.25 / 6831.z5 0.9-10 / 6831.25 0.49 r� rt �i R COLD. / 78114. M. CSI z-7 -178 1h / 131 M. 0.07 Truss ID: CAN Designed per ANSI/TPI 1.2007 Fabrication Tolerance = 20.0% Bearloga designed for an FcPerrpp value of the lesser of the truss chord 106er value or 625 for all bearings. IRC/IBC truss plate values are based on testinogg and approval as required by INC 1703 and ANSI/TPI and are reported is ESR -1118. "r 3.8 -124(1.803/ 1ll(1.Ls) 0.29 ' 4.8 .118(1.25 / 131 1.00 0.07 t 8-9-13 l 8-9-13 i 1 2 3 4 5 10.00 10.0 745 SYf 29 UPLIFT REACTIONS) : Support CBC Wind Non -Wind 1 -43 Ib ROR79ANTAL REACTION(S) support 1 -199 Ib Thi:2 199 Ib This truss is designed aging the ASCE7-10 Wind Specification Bldg Enclosed = Yes, Truss location = Not Bad Zone 88ategory = C I.I.dg Le h = 65.08 ft, Bldg Width c 72.33 It Mean ro LIght = 13.68 ft, imph = 110 Occupancy categ•ry II, Dead Load = 13.2 psf Designed as Bain 1sed Force Resisting System Low-rise and Components and Cladding Tributary Area ='35 sgft TYPICAL FOR THIS JOB UNO: REFER TO ITW BCG'S standard detail for the pi -bade standard connect on info. Piggy -back Caps supporting more than 24" of load may require additional connections and must he verified by the Building Desig.er. Wind loads are based on the spacing shown. • THIS CONNECTION REQUIRES PURLINS INSTALLED AT 24" O.C. OR LESS REGARDLESS OF THE PURLIN SPACING SHOWN ON THE BASE TRUSS. PURLINS MUST BE INSTALLED PER TPI. 45 SHIP R:968 w R:967 - - - U:-43 U:43 17-7-10 f 6 7 8 9 10 A 1 CNIL P 9�dF r..AUFd • All connector plates are ALPINE Wave 20 ga., unless preceded by 'H" for High Strength 20 ga., "S' for Super = Strength 18 ga. Plates are to be positioned per Joint Detail Report. Circled plates and false frame plates _ are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates. - 268 - Homewood Truss **WARNING!** READ AND FOLLOW ALL NOTES ON THIS DRAWING! Cnst: LEWIS WILLIAMS (CA) **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. DIR: Drive_M_0220316_L00007JJO0001 Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component W0: Drive_9_0220316_L000 Safety Information, by TPI and WTCA) for safety practices prior to performing these functions. Installers shag provide temporary bracing par BCSI. Unless Dsgnr: AW PLC = 65 WT/PLY: 99 v V ry noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a property attached rigid ceiling. Locations shown BCSI B3,87 finless TC Live( 20.00 sf LiowDor L=1.25 P=1.25 rr r=�� r� rt �i for permanent lateral restraint n webs shall have bracing tl per sections or 810, as applicable. AOPN plates to each face of truss and position as shown shwa and on the Joint Details repon, unless noted otherwise. TC $OOw P 0.00 psf $OOWDnr L=1.15 P=1.15 II IILJI�U�J If��\V\Illl 11 Alpine. a division of ITW Building Components Group Inc.. shag not be responsible for any deviation from this drawing, any tagure to build Na truss in TC Dead 14.00 of P Re MbEnd / CO / Tens P r mP AN /TW COMPANY conformance with ANSI?PI 1, or for handling. shipping, installation 8 bracing al trusses. A seal on this drawing or cover page listing this drawing, Indicates acceptance of professional engineering responsibility BC Live 0.00 psf 1.15 / 1.10 / 1.10 2820 N. Great SWPkwy. Grand Pralde, TX 75050 solely for the design shown. The suitability and use of this drawing for any structure Is the responsibility of the Building - BC Dead 8.00 psf 0. C. Spacing 2- 0- 0 Designer per ANSI?PI f Sec.2 TEUSPLUS 6.0 VER: T6.5.20 For more information see this job's general notes page and these websites: ALPINE: www.aloineitacam: TPI: www.toinstora WTCA: wwwsbeindustrv.ora• ICC: www]-affe.om $1 Code: CRC -2013. dg DEFL RATIO: L/240 TC: L/2421 1 Job Name: SINGLE FAMILY RESIDENCE Truss ID: CAPG Qtv: 2 1 BEG X. LOC REACT SIZE REQ1D 1 0- S-12 413 3.50" 1.50" 2 6- 1.13 170 3.50" 1.50" 3 11- S-13 770 3.50" 1.50" 4 17- 1.14 413 3.50" I.SO" EAI DEFLECTION (span) : L/999 NEW 11-12 (LIVE) LC 89 L= -0.06" D= -0.06" T= -0.15" -__ )eiet L -ti- - 10. 0. 0 14 e- o• o L 2.1•,1 1 5 z- ,.13 3 3. 5.13 16 3. 5.13 4 4- 9-11 17 4- a -I3 s 9. 1.13 18 6. 1.13 e 7- 3-13 19 7. 3•w 7 a- 0:1133 zo a• 9•I3 8 10- 21 10. 3.13 9u• 5.13 Lz 1,• 5-u 10 ,z• 9.13 L3 1L- 9-13 11 14. 1.13 u 14. 1.13 12 15- 5-13 ai 15- 5-13 13 IT- 7.10 Ls 17. 7.10 Tc coiv. OUR. / TENS. DUB. csi 1•L N-248 •E67 ,.LS / 1.25 / He 1.60 0.18 106 1.25 0.26 3-4 •LLB I.as / 158 1.a5 O.E3 4-3 -206 1.23 / 207 1.25 O.L9 5-6 6-7 -3E7 1.25 / -288 1.25 / 34 1.25 0.23 63 ..as0.10 7-e -z99 .1 a5 / 63 1.25 0.10 8.9 -3L7 1.25 / Sa 1.25 0.23 8-10.206 10-11 1.25 / -826 1.23 / 207 1.25 0.z9 169 1.25 0.23 11 -la -z49 1.z5 / 109 1.25 0.26 12-13 -E67 1.25 / ao 1.60 0.18 U CORP. trill./ TEn Dla. CSI 14-15 -135 1.60 / 241 1.60 O.SD is 1B•17 .135 1.60 / •135 1.60 / 241 1.60 0.31 Z41 1.60 0.31 17.18 •135 1.60 / 241 1.60 0.36 18.19 -135 1.60 / 141 1.80 0.38 19 an a0 -al •135 1.60 / -135 1.60 / a41 1.60 0.08 141 1.60 0.08 21.2a -135 1.60 / a41 1.60 0.36 22.23 •135 1.60 / 241 11.60 0.26 23.7.4 24.25 .135 1.60 / -I25 I.60 / 241 1.60 0.31 241 1.80 0.ll a5 -all -135 1.60 / 241 1.60 0.30 81 C09?. OUR. / TENS. OUR. csi 2 -IS -85 I.ES / E9 1.80 O.OI 3•le 4-17 -69 1.a5 / -B8 1.25 / 14 1.80 0.01 al 1.80 0.02 5 -IB -4g6 1.25 / 19 1.60 0.16 6-19 7-z0 -103 1.25 / -97 1. as / 17 I.80 0.08 45 1.25 0.07 8 - EI -TOE 1.25 / 11 1.60 0.06 B-22 10.23 •406 1.i3 / •B8 1.25 / 39 1.60 0.16 al 1.80 0.0E 11.24 •69 1.25 / a4 1.80 0.01 12.25 •65 1.25 / a9 1.60 0.01 TC 2a4 DPL #1 I Rtr. RC 2.4 DFL #1 I Rtr. WEB 2s4 DFL STANDARD Her (creep factor) = 2.00 Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. Loaded for 10 PSF oon•conemreat BC1.L. Hark all interior bearing locations. Persament bracing is required to Revent rotation/toppling. See CST and ANSI/TPI 1. PLATING BASED ON GREEN LUMBER VALUES. Not designed for attic storage usless noted otherwise. Designed per ANSI/TPI 1.2007 Fabrication Tolerance = 20.0% Bearings designed for an FcPerp value of the leaser of the truss chord lusher valve or 625 for all bearings. IRC/1K truss plate values are based on testinngg and approval u required by TIC 1703 and ANSI/TPI and are reported is SSR -1118. Install interior support(s) before erection. Building designer shall veritj gable loads and cave leads, if applicable. 1+1 gable brnei regnIred s 4211 intervals, if See Is ssoGa orf Ioadle Bracingplied to Details.tatt. ReferII77tWWoffCCD66WG PBIISIOIO14 and/or P2160101014 for pi ck details. grace top chord of suppor truss with 2X4 purlins spaced 2411 o/c wax. Align upper and lower trusses and support upper truss on the purlins. 1 2 3 44 6 7 8 9 10 11 12 13 11 0.00 - I V.UU SYn ww.aun wT.auo w.aua ��o R:413 R:770 R:770 R:413 U:14 U:-29 U:-29 U:-14 r 17-7-10 r 14 15 16 17 18 19 20 21 22 23 24 25 26 TYPICAL PLATE: 1.5X3 OVER 4 SUPPORTS All connector plates are ALPINE Wave 20 ga., unless preceded by "H' for High Strength 20 ga., "S" for Super Strength 16 ga. Plates are to be positioned per Joint Detail Report. Circled plates and false frame plates are positioned as shown above. Shift gable stud plates t0 avoid overlap with structural plates. UPLIFT RBACTION(S) : Support CIC Wind Non -Wind 1 -14 11 2 •E9 11 3 -29 Ib 4 -14 lb HORIZONTAL REACTIONS) support 1 -189 I► support 4 -189 16 This truss is designed using the ASCE7-10 Wind Specification Bldg Enclosed = Yes, Truss Location = Not Ead Zone mCategory = C B! g Length 6S.08 ft, Bldg Width 72.33 ft Henn roof height = 13.68 ft, mph = 110 Occupancy Category II, Dead Load 13.2 psf Designed u Hain Wind Force Resistiog System - Low•rlse and Components and Cladding Tributary Area = 54 sgft Truss designed to support 1-0-0 top chord ontlookers and cladding load not to exceed 10 PSF one face, and 24" span opposite face. Top chord must not he cwt or notched. T. No. C 72160 CIVA, P grFOF 5/6/2016 Z68 - Homewood Truss "WARNING!" READ AND FOLLOW ALL NOTES ON THIS DRAWING! Cast: LEWIS WILLIAMS (CA) "*IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. DIB: Drive_B_0220316_L00007_J00001 ^ require extreme care in fabricating, handing, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Bulling Component W0: Drive_B_0220316_L000 Safety Information, by TPI and WTCA) for safety practices prior to performing these functions. installers shall provide temporary bracing per BCSI. Unless Dsgnr: AW #LC = 109 Wr/PLY: 1464 v VTrusses to noted otherwise, top chord shall have property attached structural sheathing and bottom chord shall have a property attached dgid ceiling. locations shown lace TC Live 20.00 psf LiveDur L=1.25 P=1.25 rt �� r� rr r� I�r��\V\I.III a 83, B7 ar 870, as applicable. APPY plates to each of truss end for permanent lateral restraint n webs shall have bracing installed par BCSI otherwise. position as shown above eM on the Joint Details report, unless noted otharvrise. TC $vOW P 0.00 psf ( f SaOWDar L=1.15 P=1.15 IILII� III��L_ Alpina, a division of ITW Building Components Group Inc_ shall not be responsible for any deviation from this drawing, any failure to build the truss in TC Dead 14.00 psf Rep Plbr Bud / Camp / Teas AN /TW COMPANY conformance with ANSIfrPI 1, or for handling, shipping, installation 8 bracing of trusses. A seal on this drawing or cover page listing this drawing, Indicates acceptance o1 prefessional engineering responsibility BC Live 0.00 psf 1.00 / 1.00 / 1.00 7878 Al. Great SW Pkwy. Grand Prairto, TX 75050 solely for the design shown. The suitability and use of this drawing for any structure Is the responsibility of the Building BC Dead 8.00 psf 0. C. Spacing 2- 0- 0 Designer per ANS11TPI f Sec.2 TRUSPLUS 6.0 VER: T6.5.20 For more information see this job's general notes page and these websites: ALPINE: wvnvaloineitveeum' TPI: www .toinstom:WrCA:vvvnv.sbeindustrv.omICC: wwericessfe.ero Bldg Code: CBC -2013 DM RATIO: L/240 TC: L/24 Job Name: SINGLE FAMILY RESIDENCE Truss ID: G01 Qty: 6 ZRG I -LOC REACT SIZE ZEQ'D 1 0- 1-12 1521 3.50" 1.62" 2 21.10- 4 1522 3.50" 1.02" RAI DEFLECTION (span) : L/099 MEN 13-14 (LIVE) LC 42 L= -0.21" D= -0.24". T= .0.45" _= Idat Latiau - i o- o- 0 11 4- a• 0 z 4• 9- 0 12 :-.9 .1x s D• B -1L 13 •- B 4 9- 2. 1 14 v- o- 0 s II. 0. 0 15 Is- 0- a 612- 9-15 16 1s- z- 4 7 Is- E- 4 v 17- 6- 0 a 17- a- 0 18 as o- 0 6 zz- o- o 19 11- 0. 0 10 0. 0. 0 CR1T1uL NIOEM FORM, TC COIR. BUR. / TFRM11UI.) CSI 1-E -1887 l.as / 0.16 z4 -1871 1.zs / 0.60 s-4 -1186 1.zs / o.a7 4.5 •461.60 / a39 1.z5) 0.74 s -s -47 1.60 / z7sll.Es o.73 6-7 -1184 l.zs / 0.64 7.8 •187e 1.zs / 0.ee 8-9 •1864 1.z5 / 0.18 a COIR.(DUR.)/ TINS. DUR. CSI 10!11C o-v / 14371.33 0.34 u -lx / 1440 1.zs 0.43 1za3 / 16721.00 0.51 13.14 / 1783 o.eo 0.48 13.14 -731(o.90)1 103 1.60 0.34 14.13 / 17M0. W 0.4a 14-1s -704(0.90)/ 109 1.60 0.28 1s -w / 1e41 1.OD 0.so 16:167/ 14411.zs 0.a v -l8 / 14381.as 0.34 12.13 -108(1.80)/ 383 1.27 0.29 1s -IB 76(1.60)/ 478 1.25 0.7E Will COer. DUI. / 7HILS. DUR. I'S 275 I.ES003-1207-le / 764 1.00 01 a-leo6.17 -143 1.so / 7s l.xs 0 TB cop. buIT / Tm.(Dua.) LSI 4.19 •1344 I.Es / o.z7 19-6 •1504 1125 / 0.27 kF comp.(BUR.)/ T1013 rntn.) col 19-3 / 64 0.90 0.04 TC Zx6 DFL 82 2x4 DFL Y11 Btr. 1.2, 8-9 BC 2x4 DFL 41 A Etr. WEB 2x4 DFLSTANDARD TIB BEAR Zx4 DFL STANDARD ATTIC WB 2i4 DFL STANDARD SIR BLZ 2x6 DFL 82 Attic room load = 4S psf, pplus may added loads indicated. Iowa LL Deft. is L/360. Loaded for 10 FSF aon•rnncarremt BCLL. Attic collar tie regairea lateral restraint sham plus bracing at the panel paints of the collar tie (®less noted otherwise), or rigid sheathing is required. Designed per ANSI/TFI 1.2007 FabrIcation Tolerance = 20.0% Bearings designed for an FcPerp value of the lesser of the truss chord lumber value or OZS for all hearings. Zcr (creepe factor) = 2.00 Refer to Joint QC Detail Sheets for Cil factors and Rotational Tolerances. IRC/InaEggC trans plate valves are hosyyed on tandtANSI/iPIaaad wal as are reportedred in ES ILC 1703 pr B-1118. PLATING BASED ON GREEN LUMBER VALUES. 20 psf Live Load aappplied to bottom chord in accordance with DC/IEC code provisions. HORIZONTAL BEACTION(S) support 1 237 lb support 2 237 lb This truss is designed owing the ASCET-10 Wind Specification Bldg Enclosed = Yes, Trass Location = Not End Zone BM� Category = C Bldg 1,enjifith - 65.08 ft, Bldg Width = 72.33 ft Hearn roof height = 14.78 ft, upb= 110 Occupancy Category II, Dead Land= 15.2 psf Designed as Baia ®ind Farce Resisting System -Low-rise and Components and Cladding Tributary Area = 44 eegqft -.........LOAD CASE it DESIGN LOADS ---------------- Dir L.Plf L.Loc R.Plf R.Loc LL/TI. TC Vert 84.00 - 1- 0- 0 84.00 O- 0- 0 0.48 TC Vert 68.00 0- 0- 0 68.00 8- 8-12 0.59 TC Vert 88.00 6- 9-12 88.00 9- 0- 0 0.45 TC Vert 68.00 8- 0- 0 68.00 13- 0- 0 0.59 TC Vert 88.00 l3- 0- 0 88.00 IS- Z- 4 0.95 TC Vert 88.00 1S- 2. 4 68.00 22- 0- 0 0.58 TC Vert 84.00 2Z- 0. 0 84.00 23- 0- 0 0.48 BC Vert 16.00 0- 0. 0 16.00 6- 8-12 0.00 EC Vert 106.00 6- 9-12 106.00 15- Z- 4 0.75 C Vert 16.00 Is- 2. 4 16.00 22- 0- 0 0.00 4-6 V 20.00 9- 0- 0 20.00 13- 0- 0 0.00 '7t�y.ppee lbs I.Loc LL/TL Fastener TC Yet 0.0 0- 1-12 1.00 TC Vert 0.0 21-10- 9 1.00 RC Vert 53.0 6. 9.12 0.00 SC Vert 53.0 1S. 2. 4 0.00 - All connector plates are ALPINE Wave 20 ga., unless preceded by "H" for High Strength 20 ga., "S" for Super Strength 16 ga. Plates are to be positioned per Joint Detail Report. Circled plates and false frame plates 5/6/2016 are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates. 11-0-0 11-0-0 cast: LEWIS WILLIAMS `1 2 3 4 f5 6 7 8 91 Trusses require extreme care in fabricating, handling, riNpping, installing and bracing. Refer to and follow the latest edition of SCSI (Building Component 1r 8.00 10 00- _10-0 a 710.0 Dsgnr: AW #LC = 84 Wr/PLY: 196 6X10 noted otherwise, top chord shall have property attached structural sheathing and bwaom chord shall have a property attached dgid ceiling. Locations shown Appy to face truss TC Live 20.00 psf - - L1veDar L-1.25 P-1.25 3X6 3X6 TC St10W (Pf) 0.00 psf $aOWDar L=1.15 P=1.15 2.5X4 19 2.5X4 TC Dead 14.00 psf 1.5X3 AN ITW COMPANY conformance with ANSIrrPI 1, or for handling, shipping, Installation 2 bracing of Dunes. A seal on this drawing or cover page listing this drawing, Indicates acceptance of prefessional engineering responsibility 9-6-11 7X8 2620 N. Great SWPkwy. Grand Prald., TX 75050 7X8 10 BC Dead 8.00 psf 0. C. Spacing - 2- 0- 0 7 0 SHIP 4X6 Z TRUSPLUS 6.0 {EB: T6.5.20 4X6 2 2or 4 04-11 1.5X3 2.5X4 2.5X4 1.5X3 0_4-11 4X6 2.5X4 7X10 B2 B1 W:308 - W:308 R:1521I R:1522 U: 5310534 U 0 22-0-0 10 11 12 13 14 15 16 17 181 HORIZONTAL BEACTION(S) support 1 237 lb support 2 237 lb This truss is designed owing the ASCET-10 Wind Specification Bldg Enclosed = Yes, Trass Location = Not End Zone BM� Category = C Bldg 1,enjifith - 65.08 ft, Bldg Width = 72.33 ft Hearn roof height = 14.78 ft, upb= 110 Occupancy Category II, Dead Land= 15.2 psf Designed as Baia ®ind Farce Resisting System -Low-rise and Components and Cladding Tributary Area = 44 eegqft -.........LOAD CASE it DESIGN LOADS ---------------- Dir L.Plf L.Loc R.Plf R.Loc LL/TI. TC Vert 84.00 - 1- 0- 0 84.00 O- 0- 0 0.48 TC Vert 68.00 0- 0- 0 68.00 8- 8-12 0.59 TC Vert 88.00 6- 9-12 88.00 9- 0- 0 0.45 TC Vert 68.00 8- 0- 0 68.00 13- 0- 0 0.59 TC Vert 88.00 l3- 0- 0 88.00 IS- Z- 4 0.95 TC Vert 88.00 1S- 2. 4 68.00 22- 0- 0 0.58 TC Vert 84.00 2Z- 0. 0 84.00 23- 0- 0 0.48 BC Vert 16.00 0- 0. 0 16.00 6- 8-12 0.00 EC Vert 106.00 6- 9-12 106.00 15- Z- 4 0.75 C Vert 16.00 Is- 2. 4 16.00 22- 0- 0 0.00 4-6 V 20.00 9- 0- 0 20.00 13- 0- 0 0.00 '7t�y.ppee lbs I.Loc LL/TL Fastener TC Yet 0.0 0- 1-12 1.00 TC Vert 0.0 21-10- 9 1.00 RC Vert 53.0 6. 9.12 0.00 SC Vert 53.0 1S. 2. 4 0.00 - All connector plates are ALPINE Wave 20 ga., unless preceded by "H" for High Strength 20 ga., "S" for Super Strength 16 ga. Plates are to be positioned per Joint Detail Report. Circled plates and false frame plates 5/6/2016 are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates. 288 **WARNING!** READ AND FOLLOW ALL NOTES ON THIS DRAWING! cast: LEWIS WILLIAMS -Homewood toss (CA) **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. DIB: Drive_i1_0220316_L00007_j00001 Trusses require extreme care in fabricating, handling, riNpping, installing and bracing. Refer to and follow the latest edition of SCSI (Building Component W0: Drive_ M_0220316_L000 Satety Information, by TPI and VVTCA) for safety practices prior to performing Nese functions. Installers shall provide temporary bracing per BCSI. Unless Dsgnr: AW #LC = 84 Wr/PLY: 196 v V iV noted otherwise, top chord shall have property attached structural sheathing and bwaom chord shall have a property attached dgid ceiling. Locations shown Appy to face truss TC Live 20.00 psf - - L1veDar L-1.25 P-1.25 r� r7 O I �\ I I ALM for permanent lateral restraint n webs shall have bracing installed per Cher sections 83, B7 or 810, as applicable. plates each o/and positlon as shown above and on the Joint Details report unless naiad o he w se. TC St10W (Pf) 0.00 psf $aOWDar L=1.15 P=1.15 U v Alpine, a division of ITW Building Components Group Inc., shall not be responsible for any deviation from this drawing, any failure to build the truss in TC Dead 14.00 psf Rep R6r End / Comp / Tens AN ITW COMPANY conformance with ANSIrrPI 1, or for handling, shipping, Installation 2 bracing of Dunes. A seal on this drawing or cover page listing this drawing, Indicates acceptance of prefessional engineering responsibility BC Live 0.00 psf 1.15 / 1.10 / 1.10 2620 N. Great SWPkwy. Grand Prald., TX 75050 solely for the design shown. The suitability and use of this drawing for any structure /s the responsibility of the Building BC Dead 8.00 psf 0. C. Spacing - 2- 0- 0 Designer per ANSI/rPI f Sec.2 TRUSPLUS 6.0 {EB: T6.5.20 For more information see this job's general notes page and these web liter ALPINE: www aloineitwcom:TPI: wvwvminston, WrCA.www sbendustryone: ICC: vnvwicce.feom Bldg Code: CRC -2013 DEFL RATIO: L/240 TC: L/24 Job Name: SINGLE FAMILY RESIDENCE Truss ID: G02 Qtv: 8 1 BRG I -LOC REACT SIZE REM 1 0- 1-12 1437 3.50" 1.53" 2 21-10- 4 1522 3.50" 1.62" MAX DEFLECTION (s an) : L/927 M 16-17 (LIVE) LC 44 L= -0.28" D= -0.17" T= -0.45" Jr i 0. 4 11 4 o• o• 0 11 4• a- o 24- 8- 0 12 8- 9-72 s 6- 8-I2 13 8-11- 8 4 9- L- 1 14 11- 0- 0 s 11- o- o Is Is- 0- 8 8 12- 8-15 18 15• L- 4 7 15- L- 4 17 11- 6- 0 8 11. 0• o le Ez• 0- 0 9 zz- o- 0 19 11- o- 0 100• o- o CRITILL I®on FORCES, 7C CORP. Rlil. / TWLS.(DUR,) CSI 2-2 .1864 1.ES / 0.19 L-3 -1671 1.2 5 / 0.67 3-4 -1186 I.zi / 0.63 4-s -378 1.60 / 419(11 'I 0.73 5-a -382 1.60 / 414 1.60 0.73 ea -1194 1.zs / 0.83 1-8 •1877 1.25 / 0. as 8-9 •1864 l.xs / 0.19 sc aM. Rua. / TQIS. DUN. CSI 10-11 -740 1.60 / 21040 1.60 0.34 u -1z an 1.60 / 2032 1.60 0.59 121-13 .661 1.60 / /680 1.00 0.55 3- 4 / 1771 0.90 0.48 15.14 •719(0.90)/ 711 1.80 0.31 14-15 / 71. 0.90 0.48 14.15 -692(0.80)/ 7L0 1.60 O.EB Ns -16 .657(((((1.603)))/ INS 1.00 0: 'S's 18.17 -7L8 1.60 / 203E 1.60 0.59 17.18 -738 1.60 / LO14 1.80 0.34 1L-11 -B4L 1.60 / 818 1.60 O.29 1s-16 -sae 1.60 / 845 1.60 0.3E O COM.((DUt.)/ TWICS. DUI. CSI Z-111 -2IS(I.603/ 256 1.60 0.08 L•12 -799((1.60 / 4L9 1.60 0.24 s-120.40 7-16 / 751 l.o0 0.41 8-10 -so7(I.so)/ Oso 1.so 0.35 8.17 -ELE 1.60 / Z63 1.60 0.08 TR COM.( OUR.)/ TENS. (DUt.) CSI 4-19 •Is41 1.Li / 0.217 t8-8 -1543 1.215 / 0.27 AF COM.(auR.)/ TW115. (DEN.) CSI 19.5 / 64(0.90) 0.04 268 - Homewood /meTruss v V (C ra ALMNCE AN ITU COMPANY 920 N. Groat SW Pkwy. Grand Prolde, TX 75050 TRUSPLUS 6.0 VER: T6.5.20 TC 2n6 DFL 82 2z4 DFL 81 A Btr. 1-2, 8-9 BC ZEE DFL #1 A Btr. WEB 2x4 DFL STANDARD 2z4 On #1 4 Btr. 12-3, 16-7 TIB BEAM 2z4 DFL STANDARD ATTIC WE 2x4 DFL STANDARD STIR BLB 2z6 DFL #2 IRC/IBC truss plate values are based on testing and approval as required by IBC 1703 and ANSI/TPI and are reported in R-1118. PLATING BASED ON GREEN LUMBER VALUES. + + + + + + + + + + + + + + + + + + + + + + Designed for 2.0 R lbs drag load applied horizontally in either direction to the top chord panel points, with dead + 0 % live loads using load duration = 1.60. Horizontal reaction = 2.0 R lbs at each hearing Individually. Conaeetion by others. + + + + + + + + + + + + + + + + + + + + + + 9-6-11 4X6 0-4-11 B1 W:308 R:1437 U: Designed per ANSI/TPI 1-2007 Fabrication Tolerance = 20.0% Bearings designed for an FeFerp value of the lesser of tie truss chord lumber value or 625 for all bearings. Bcr (creep factor) = 2.00 Refer to Joist QC Detail Sheets for Cq factors and Rotational Tolerances. Attic room load = 45 psf, Ins any added loads indicated. Ran LI. 5ef1. is L/360. Loaded far 10 PSP noa-concurrent BILL. Attic collar tic requires lateral restraint shorn plus bracing at thepanel points of the collar tie (unless noted otherwise), or rigid sheathing is required. 20 psfLiveLoad applied to bottom chord in accordance with IBC/IBC code provisions. 11-0-0 11-0-0 '1 2 3 4 �5 6 7 8 9' 1� 10.00 82 W:308 R:1522 U: 220-0 W 10 11 12 13 14 15 16 17 18 All connector plates are ALPINE Wave 20 ga., unless preceded by "H" for High Strength 20 ga., "S- for Super Strength 18 ga. Plates are to be positioned per Joint Detail Report. Circled pates and false frame plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates. "WARNING!" READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. Trusses require e#reme care in fabricating, handing, shipping, installing and bracing. Refer to and follow the latest edition of SCSI (Building Component Safety Information, by TPI and W TCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have property attached structural sheathing and bottom chord shall have a property attached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details report unless noted otherwise. Alpine, a division of ITW Building Components Group Inc., shall not be responsible for any deviation from this drawing, any failure to build the truss in conformance with ANSI?PI 1, or for handling, shipping, installation a bracing of trusses. A seal on this drawing or cover page Ilsdng this drawing, Indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of this drawing for any structum Is the responsibility of the Building Designer per ANSI/TPI f SBC.2 For more information see Nis job's general notes page and these web rhea: HORIZONTAL REACTIONS) support 1 1999 Its support 2 2000 Ib This truss is designed using the ASCET-10 Wind Specification Bldg Enclosed = Yes, Truss Location = Not End Zone NCategory = C Bldg Length = 85.08 ft, Bldg Width = 72.33 ft Nears roof height = 14.78 ft, mph = 110 Occaparscy Category II, Dead Load = 13.2 psf Designed ae Hain Wind Porte Resisting System Low-rise and Components and Cladding Tributary Area = 44 sqft ---------- LOAD CASH #1 DESIGN (AADS ---------------- Dir L.Plf L. Inc R.PIf R.Ioc LL/TL TC Vert 68.00 0- 0. 0 68.00 8- 9-12 0.59 TC Vert 88.00 6- 9-12 88.00 9- 0- 0 0.45 TC Vert 68.00 9- 0. 0 68.00 13. 0- 0 0.59 TC Vert 88.00 13- 0. 0 88.00 15- 2- 4 0.45 TC Vert 68.00 IS. 2- 4 68.00 22- 0- 0 0.59 TC Vert 84.00 22- 0- 0 84.00 23- 0- 0 0.48 BC Vert 16.00 0- 0- 0 19.00 6- 9-12 0.00 BCVert 108.00 6- 9-12 106.00 1S- 2- 4 0.75 BC Vert 16.00 15- 2- 4 16.00 22- 0- 0 0.00 4-6 V 20.00 9- 0- 0 20.00 13- 0- 0 0.00 TTyyppee lbs 1.Loc u/TL It"tener 7C Yert 0.0 21-10- 4 1.00 BC Vert 53.0 8. B•lE 0.00 BC Vert 53.0 1S- 2- 4 0.10 T. No. C 72160 'eT CN0.. P 5/6/2016 Cast: LEWIS WILLIAMS DIB: Drive_I1_0220316_L00007_j00001 W0: Drive_M_0220316_L000 Dsgnr: AN #LC = 88 Wr/PLY: 194 TC Live 20.00 psf LiveDur L=1.25 P=1.25 TC Snow(Pf) 0.00 psf SnowDar L=1.15 P=1.15 TC Dead 14.00 psf Rep Mbr End / Coup / Tens BC Live 0.00 psf 1.15 / 1.10 / 1.10 BC Dead " 8.00 psf O.C.Spacing` 2-"0- 0 Code: CRC -2013 JDEFL RATIO: Job Name: SINGLE FAMILY RESIDENCE Truss ID: GOG 4��- 19.20 / Qty: 1 BRG 1 X -LOC REACT SIZE RE ;D 0- 2. 0 210 4.05" 1 Or, TC 2x4 DFL 81 b Btr. We► bracing required at each location shown. UPLIFT REACIION(S) : L1•LL L2-L3 2 1- 4- 0 155 3.50" 1.50" BC 2.4 DFL 81 A Btr. WEB Zz4 DFL STANDARD ® Refer to I for proper regwired lateral restraint. For alteroativo web bracing, Support 1 CRC Wind •39 Ib Non -Wind 3 2- 8- 0 154 3.50" 1.50" Designed r ANSI/TPI 1-2007 see ITWBCG's standard details. E -65 Ib 9f-11 4 4- 0. 0 1673.50" 1.50" Bearings designed for oa FcPerp value of the Fabrication Tolerance = 20.0% 3 -16 lb SnowDur L=1.15 P=1.15 5 5- 4. 0 I8l 3.50" 1.50" lesser of the truss chord lumber wlae or Xer (creep factor) = 2.00 4 -13 Ib n 8 6- 8. 0 197 3.50" 1.50" 625 Far all bearings. Refer to Joint QC Detail Sheets for 5 -6 lb 3 -LO 7 8 - 0. 0 216 3.5o" 1.50" 1RC/IBC truss plate values are based on Cq factors and Rotational Tolerances. 6 .7 Ib .176 .193 8 9 9- 6. 0 11- 0. 0 277 3.50" 1.50" 177 3.50" 1.50" testi and a rowl u required by IRC 1703 Landed for 10 FSF non -concurrent BCLL. 7 -7 Ib 1.25 / 10 12- 6- O 277 3.50" 1.50" and anL/TPI and are reported in R-1116. RS Perttanamt bracing is required to Ilar► all interior bearing locations. Install interior saapppert(s) before erection. 8 9 -9 U lb •11 14- 0. 0 216 3.50" I.50'r prevent rotatlon/toppling. See Building designer shall verify loads 10 -30 -9 I► 12 13 15- 4- 0 16- 8- 0 197 3.50" 1.50" 181 3.50" 1.S0" BCSI aad ANSI/TPI 1. gable and eave loads, if applicable. 11 -7 I► 14 l8- 0- 0 167 3.50 1.50" PLATING BASED ON GREEN LunnVALUES. [+] gable bracing required 0 42" iatervals, 12 -7 Ib 15 19- 4- 0 154 3.50" 1.50" HORIZONTAL REACTION(S) If exposed to wind load applied to face. 13 .6 Ib 16 20- e- 0 155 3.50" 1.50" support 2 134 Ib See 17WKG's Gable Bracing Details. 114 -13 Ib 17 21-10- 0 210 4.05" 1.50" support 16 -134 l► This truss is designed using the IS -18 Ib RAX DEFLUT-I0111 sppoa Not designed for attic storage unless ASCE7-10 Wind Specification 16 -65 Ib L/999 1�1 9-10((LIVH)-LC I L= 0.00" D= 0.00" T= 0.00" noted otherwise. Bldg Enclosed = Yes, Truss Location = Not End Zone 17 -39 Ib CILMCAL 1®0771 FORM: Exp Category = C Tr an. FUR. / TOJs. OUR. col Bldg Length = 65.08 it, Bldg Width = 72.33 ft t -L -Est 1.60 / Ise 1.60 0.01 an ro0£ height = 14.78 ft, nph = 110 L-3 3-4 •230 1.60 / .165 1.60 / lie 1.60 0.02 80 1.60 0.0E Oe Cate o II, Dead Load = 13.2 psf cuPnacY & I'9 / 4-5 -117 LLS / 77 1.60 0.02 Des1 asBaso Wind Force Resisting System s-6 -1111. as / 64 1.60 0.01 - Low-rise and Components and Cladding 9.7 -127 1.25 / $0 1.60 0.01 Tributary Area = 72 sqft 7-8 -134 1.25 / se 1.60 0.05 Truss designed to support 1-0.0 top chord outloohers e -e 9-10 •153 1.as1.60 -I53 1.28 / o.os Its 1.fi0 0.05 and claddingload not to exceed 10 PSF one face, and 10-11 -134 1.x5 / se 1.60 0.05 24" span opposite face. Top chord must not be cwt or 11.12 a27 Las / 50 1.60 0.01 - notched. 12.71 -122 1.25 / 64 1.60 0.03 2 3 6 6 9 D 2 3 14 `15 13-14 14.11 15.10 -117 1.25 / -lbs 1: so / -no Iso / Till.60 0:02 90I:aO O.OL usl.eo o.oz10 00 -10.0 -283 1.00 / Ise 1.00 0.01 16`;6 Do.106J" T% f9 �3 6CST 4��- 19.20 / 0.01 L0101 / 0.91 areength d are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates. L1•LL L2-L3 / / 0.01 0.01 L3-L4 1011 "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. 2•-25 / o.0. as. as L6 -L7 1011 / 0.01 Dsgnr: AW #LC = 40 WT/PLY: 221 i 9f-11 as-xtra LiveDar L=1.25 P=1.25 o:a, ^ n L9-30 30-31 / / 0.01 0.01 SnowDur L=1.15 P=1.15 31-32 / 0.01 3L -as 33-34 / -100(1.60)/ 0.01 IS4(1.60) 0.05 conformance with ANSUTPI 1, or for handling, shipping, installation 8 bracing of trusses. A seal on this drawing or cover page listing this drawing, Indicates acceptance of professional engineering responsibility n re>Q. 0ua. / T®Lt.10.ua. col 2X044: 2 -IB -104 1.25 / 0.0z 63 0!0a 2 3 -LO .131 .145 1.25 / 1 -LS / 35.60 0.0E 0-4-114-21 311.60 0.035.22 THUSPLUS 6.0 NEB: T6.5.20 -160 I.ES / 251.60 0.06 6-23 7.24 .176 .193 7.25 / 1.25 / IB1.80 O.IO 181.60 0.11 8-25 -IE6 1.25 / 0.14 9-x6 -132 1.25 / 45(1.60) 0.08 10.27 -126 1.21 / 0.14 SXR 5X6 1]•LB -193 l.Es / 1111.80 O.Is 1z -x9 d7e 1.28 / 19 1.80 0.10 13•SO •780 1.E5 / LS I.Go 0.08 -2f -D- 14-31 -141 l.Ls / 31 1.60 0.01 8 9 20 2 22 23 2 2 26 2 28 29 30 3 32 15.3E -733 1.25 / Ss 1.60 0.0E 18.33 •104 I.LS / 83 1.00 0.0E 8-L$ •REB I.Ls / 0.14 10-27 •126 1.25 / 0.14 TYPICAL PLATE: 1.5X3 OVER CONTINUOUS SUPPORT T. No. C 72160 "H' "S" 4��- All connector plates are ALPINE Wave 20 ga., unless preceded by for High Strength 20 ga., for Super - - 16 Plates are to be positioned per Joint Detail Report. Circled plates and false frame plates 5/6/2016 areength d are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates. 268 - Homewoodruss "WARNING!" READ AND FOLLOW ALL NOTES ON THIS DRAWING! Cast: LEWIS WILLIAKS (CA) "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. DIB: Dr1ve_H_0220316_L000071j00001 require enreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow Na latest edition of BCSI (Building Component W0: Drive_M_0220316_L000 Safety Information, by TPI and WfCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless Dsgnr: AW #LC = 40 WT/PLY: 221 V VTrusses noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a property attached rigid ceiling. Locations shown for lateral have bracing installed BCSI B3. B7 BID, Apply to face truss TC Live 20.00 LiveDar L=1.25 P=1.25 Q ��UJ ��� ^ n permanent restraint of webs shall per sections or as applicable. plates each of and position as shown above and on the Joint Details report, unless noted otherwise. psf TC Snow(Pf) 0.00 psf SnowDur L=1.15 P=1.15 IIJI�\FIJI Alpine. a division of ITW Building Components Group Inc.. shag not be responsible for any deviation from this drawing, any failure to build the truss in . P TC Dead 1466 psf Be Mbr Bud / Coup/Teas P AN RTW COMPANY conformance with ANSUTPI 1, or for handling, shipping, installation 8 bracing of trusses. A seal on this drawing or cover page listing this drawing, Indicates acceptance of professional engineering responsibility BC Live 0.00 psf 1.00 / 1.00 / 1.00 2820 N Graaf SWPRwy. Grand Prairie, TX 75050 solely for the design shown. The suitability and use of this drawing for any structure Is the responsibility of the Building BC Dead 8.00 psf 0. C. Spacing 2- 0- 0 Designer per ANSI/TP/7 Sec.2 THUSPLUS 6.0 NEB: T6.5.20 For more information see this job's general notes page and these web sites: ALPINE: TP WTCA:MM Rticinduam, arc:ICC: www iecsafe.am Bldg Code: CBC -2013 DBFL RATIO: L/240 TC: L/24 Job Name: SINGLE FAMILY RESIDENCE Truss ID: GTI Qty: 1 NBC -LOC BRAC: SMREQ'D TC 2" DFL ill � Designed per ANSI/TPI 1.2007 Required bearing widths and bearing areas 1 0. 1-12 813 BG! 1.50" BE2x4 DFL O1 8 Ntr. Fabrication Tolerance = 20.0% apppply when truss not supported in a hanger. 2 3- 8-12 813 B6! 1.50" WEB 2x4 DFL STANDARD Bearings desigoed for an FcPetrpp value of the OPLIFT lBilC7ION(S) BRGBANGER/CLIP NOTE GBL RIK 2x4 DFL STANDARD lesser of the ttass chord lumber value or Support CiC Wind Non -Wind 1 RUS26 Her (creep factor) = 2.00 625 for all bearings. 1 -194 Ib 2 -KUS26 IRC/INC tress plate values are based on ' Refer to Joint QC Detail Sheets for 2 -194 Ib Support Connection(s)/Ban er(s) are mt desiggnoed for horizon al loads. testing and approval as required by IBC 1703 Cq factors and Rotational Tolerances. HORIZONTAL NEACfION(S) SEE SIHPSON CATALOG � AN and are reported in ESR -1118. Loaded for 10 PSF eon -concurrent Wu. support 1 .113 lb FOR ADDITIONAL INSTALLATION NOTES permanent bracing is required to Drainage shall be provided to avoid ponding. rapport 2 -113 Ib HAI DEFLECTION (span) : event rotation/toppling. See Building designer shall verify gable loads • This tress is designed .sing the L/899 1®1 4-5 (LIVE) = 049 . L= -0.01" D= •RIA: T= -0.02" and ANSI/TPI 1. PLATING BASED ON GREEN LU10)EN VALUES. and eave loads, if applicable. [+] gable bractag required ! 42" intervals, ASCE7-10 Wind Specification Bldg Enclosed = Yes, - E%. WE DEF CRITERIA End verticals are designed for axial loads if exposed to wind load applied to face. Truss Location = Not End Zone 0.0120 IN HEN S. 3; 7= 0.02" only, unless noted otherwise. Not designed for attic storage unless See ITWNCG's Gable Bracing Details. a- Category = C Bldg Length - 65.08 ft, Bldg Width = 72.33 ft J.int 1 -ti- - noted otherwise. TC Snow(P� 0.00 psf Henn roof height = 12.00 tit, h = 110 1 0- o- 0 3 o- 0- 0 E 1-11- 9 5 1-10- 8 Alpine. a division of RTW Building Components Group Inc.. shall not be iesponsibla for any deviation from this drawing, any failure to build the truss in TC Dead 14.00 psf P Occupancy Cat o I1, De¢d Load = 13.2 psf 5 3-10. s iO1Ces: conformance with ANSI/TPI 1, or for handling, shipping, installation 8 bracing of trusses. As eal on this drawing or cover page listing this drawing, Indicates acceptance of professional engineering responsibility •, BC Live 0.00 psf. Designod no Ra n tad Force Resisting System Low-rise Compriaents Cladding CUTICAL r®an Tc T®i4. out. CSt solely for the design shown. The suitability and use of this drawing for any structure Is the responsibility of the Building - •' BC Dead 8.00 psf and and Tributary Area = 29 sqft 1-z ol.sol/ 9j1.9m3 o.oe 2.3 1.60)/ ST 1.94 0.04 Designerper ANSI?PI I Seat _ .. Vertical members exposed to wind: S- 3 .s3 For lolnehcormationsee minjob's eanerainatespage anameseweb it es: ALPINE: www .alolneihv.eom� TPI: ,' WrCA:-locindustrv.ora: ICC: BI,r,� Code: CRC -2013 dg ----------LOAD CASE 41 DESIGN LOADS ________________ sC CORP. (OUa.)/ TEG.((OUt.)) CSI Dir L.PIf L.Loc R.Plf R.Loc LL/YL 4.5 / am(I. zs) 0.1E TC Vert 68.00 0- O- 0 68.00 3-10- 8 0.59 it "3 / ((oDtR) CSI t -r •z9 1.25 / 19(1.00) o.OE RC Vert 16.00 O- 0- 0 16.00 3-10.8 0.00 ,Type lbs I.Loc LL/7L Fastener 1-a -550 l.zs / 0.15 2.5 •550 1.25 / 0.15 „TC {'set 800.0 1-11- 4 0.48 3-5 -a9 1.25/ 19(1.60) o.zo 1 2 3 900# 1 2.5X4 1 2.5X4 z.sxa LL T. T Muses Muses _ W:308 W:308 R:613 ' 3-10-8 R:613 - U:-194 '4 5' No. C 72160 TYPICAL PLATE: 1.5X3 QP CA1aF"" P :ATI connector plates are ALPINE Wave 20 ga., unless preceded by "H" for High Straingth 20 ga., "S" for Super , _c_ ...� ;,..... _ _ Strength 18 ga. Plates are to be positioned per Joint Detail Report. Circled pates and false frame plates '- are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates. c 5�6/�O 6 268 - Homewood Trus "WARNING!*" READ AND FOLLOW ALL NOTES ON THIS DRAWING! Cast: LEWIS WILLIAMS (CA) "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. DIR: Drive_M_0220316_L00007-J00001 rerluire extreme care in fabricating, haneling. shipping, instating and bracing. Rete, to and follow the latest edition or SCSI (Building Component W0: Drive_N_0220316_L000 Safety Information, by TPI and WTCA) for safety practices prior m performing these functions. Installers shag provide temporary bracing per BCSI. Unless Dsgnr: AW ULC = 51 Wf/PLY: S7 V VTrusses 1Y noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a property attached rigid ceiling. Locations shown for lateral have bracing installed BCSI B3. B7 BiO, Apply to face truss TC Live 20.00 psf LiveDnr L=1.25 P=1.25 rr r�� r� rt r� 'ILfl�llL11�7 I l�r��\v`l permanent restraint of webs shall per sections or as applicable. plates each of and position as shown above and on the Joint Details report unless noted othermse. TC Snow(P� 0.00 psf SnourDur L=1.15 P=1.15 Ill'ILLrJ Alpine. a division of RTW Building Components Group Inc.. shall not be iesponsibla for any deviation from this drawing, any failure to build the truss in TC Dead 14.00 psf P Re Nbr Bad / Com /Teas P P AN ITW COMPANY conformance with ANSI/TPI 1, or for handling, shipping, installation 8 bracing of trusses. As eal on this drawing or cover page listing this drawing, Indicates acceptance of professional engineering responsibility •, BC Live 0.00 psf. 1.00 / 1.00 / 1.00 1870 N. Great SW Pkwy. Grand Prairie, TX 75050 solely for the design shown. The suitability and use of this drawing for any structure Is the responsibility of the Building - •' BC Dead 8.00 psf 0. C. Spacing 2- 0- 0 Designerper ANSI?PI I Seat _ .. TRUSPLUS 6.0 {/EE: T6.5.20 For lolnehcormationsee minjob's eanerainatespage anameseweb it es: ALPINE: www .alolneihv.eom� TPI: ,' WrCA:-locindustrv.ora: ICC: BI,r,� Code: CRC -2013 dg DBBL•-RATIO L/240 TC: L/24 Y Job Name: SINGLE FAMILY RESIDENCE Truss ID: M11 Qty: 14 BBG Y -LOC BRACT SIZE REQ'D TC 2z4 DFL SI D Btr. Desiggnaed per ANSI/TPI'1.2007 UPLIFT' REACTION(S) '- I 0- 1-12 SSB 3.50" I.SO" BC 2.4 DFL 81 D Btr. Fabrication Tolerance = 20.0% Support CDC Wind Non -Wind -.- 2 11- 8-10 1048 1,75" I,SO" 3 18-11- 8 204 1,50" 1.50" WEB 2z4 DFL STANDARD Bearings designed £or an FcPerrpp valine of the I -79 16 Her (gree factor) = 2.00 lesser of the truss chord lumber value or 2 -418 lb 4 I1- 7. 0 175 1,50" 1.50" Beer to Joint QC Detail Sheets for 625 for all bearings. 3 -85 lb MAX DEFLECTION (span) : L/569 BBN 0-0 (LIVE) � 53 re Cq factors and Rotational Tolerances. IRC/11C truss plate "Ines abased on 4 -141 lb -458 lb - Leaded for 10 PSI non-concurmat BCLL, testinogg and approval as required by IBC 1703 HORIZONTAL REACTION(S) L= "0.15" D= -0.20" T= -0.38" Barb all interior bearinnlocations. and ANSI/TPI and are reported in PSH -1118. support 1 358 lb HAY DEFLECTION (cant) : L/999 HEN 0-0 (LIVE) LC 53 PLATING BASED ON GREEN L&BER VALUES. Install interior support(s) before erection. support 4 358 Its L= 0.00" D= 0.01" T= 0.01" This truss is designed using the Not desirded for attic storage unless ASCE7.10 Wind Specification_ EK.WB DEF CRTTEBIA:L/120 noted of erwime. Bldg Enclosed = Yes, IN 1E! 6. 3; T= 0.02" Truss location = Not Pad Zone _= J•iat 1-tl•as ® Category = C I o- 0- 0 4 0- 0- 0 x 7. 3. 0 5 7. 3. 0 li Le th = 85.08 ft, Bldg Width = 72.33 ft Dees hei ht ft, h 3 11. 7 -Ix 8 14 7-12 CRM EWER 1026. res£ B = 11.9S ■ = 110 Occupancy Cutegory II, Dead Toa = 13.2 psf ' OTC CORP. Da. / TWiS.(DUN.) Is1 -z -734 l,zs / 0.40 Designed as gain Wind Farce Resisting System law Components CladAimg L•3 -Els 1.00 / 40 1•IS o.zs -tea 1.as / zas 1.25 - -rise and and Tributary Area = 29 sq£t 0.0 0.46 o -o -e3 1.zs / sJ I.L5 0,4s Vertical members e :posed to wind: 6- 3 0.0 -1 I.zs / 0 1.60 0.00 a COIR. DU1. / 70i4. DUD. CSI 4-5 •158(1.x03/ 838 I.LS 0,3E 5-8 •158(((1.803)/ BLB 1.L5 0. 05 B-0 0 1.L5 / 858 1.80 0.05 - 0-0 O /.LS / 0 1,80 0.00 f1 call ca + L -s / LBO I.LS 0.11 L -x 73s(/.zs)/ ne 1101 0,30 81,51 1 2 3 + 3-a -Ela 110 / ISSo.as - 4.00 B3 WADS R:204 U:-85 1.5X4 T - ,6_7_14 6X8 W: W:112 I 6-11-12 R:1048 SHIP U: 419 426 3X6 l 0-3-13 B1 1.5X3 5X684 ,QpfES$J W:308 W:108 r� R: 11-8-10 R:4 19-0-4 FV.T. TiQN A • U:-73-73 .. U:-4558 - - J� �Y 4 5 No. C 72180 OVER 4 SUPPORTS � CNIL P Q�QFCAU f • All connector plates are ALPINE Wave 20 ga., unless preceded by "H' for High Strength 20 ga., "S" for Super Strength 18 ga. Plates are to be positioned per Joint Detail Report. Circled pates and false frame plates c /� A_ Q. • . are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates. - SI6I2O 1 V 268 - Homewood Truss **WARN/NGT ** READ AND FOLLOW ALL NOTES ON THIS DRAWINGI Cast: LMS WILLIAMS (CA) **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. DIB: Drive_M_0220316_L00007-J00001 ^ Trusses.."ira aurema care in lebricetlng. henmine, ahippine, installing and bracing. Refer to and follow the latest edition of SCSI (Building Component- W0: Dri Ve_M_0220316_L000 safety Information, by TPI and WTCA) for safety practices prior to performing these functions. Installers shag provide temporary bracing per BCSI. Unless Dsgnr: AW :ILC = SS WI'/PLY: 7 94 ra no ted othen ise, top chord shall have propeM attached structural sheathing and bottom chord shall have a Drapery attached rigid ceiling. Locations shown for lateral SCSI 83. face have bracing finless TC Live( 20.00 pp'9f L=1.IS' P=1.25 ��� e� r7 �\ I I permanent n per sections B7 or B70, as applicable. Apply plates to each of truss and above and n webs snail position as mown above and on the Joint Details repon, unless noted otherwise. TC SOOW P 0.00 sf SnoLivwlar SawWDar L=1.15 P=1.15 U v Alpine. a division or Ira Building Components Grasp Inc., shag int be responsible for any deviation from this drawing, any tenure to build the truss in TC Dead 14.00 psf Rep Mbr Bad / Comp / Tens AN ITW COMPANY conmrmanoa with ANSlrrPI t, or for handling, shipping. installation a bracing of trusses. A seal on this drawing or cover to listing this drawing, indicates acceptance o1 professional engineering responsibility BC Live 0.00 psf - 1.15 / 1.10 / 1.10 1820 N. Graaf SIN Pkwy. Grand Praline, TX 75060 solely for the design shown. The suitability and use of this drawing for any structure Is the responsibility of the Building BC Dead 8.00 psf 0. C. Spacing 2- 0- 0 Designer perANSI/TPI 1 Seat TRUSPLUS 6.0 VER: T6.5.20 For more information see this job's general notes page and Nwebsites: eb sites: ALPINE: ww,v.aloineitw.eom: TPI; ' WTCA: vn6v.abcinduetrv.cup :ICC: vNm.icrsafe.ora 11BIdg Cade: CRC -2013' DEFL RATIO: L/240 TC: L/24 4` Iii, I 4 Job Name: SINGLE FAMILY RESIDENCE . Truss ID: M11G Qty: 2 REG 1 -LOC REACT SIZE REQ'D TC 2x4 DPL #1 6 Rtr. Designed per ANSI/TPI 1.2007 UPLIFT 8BAC7ION(S) -. 1 0- S. 1 2388 10.12" 1.50" RC 2z4 DFL #1 i Stir. Fabrication Tolerance = 20.0% Support CAC Wind Non -Wind 2 18-11- 8 204 1.50" 1.50 FILL CRD 2z4 DFL STANDARD Rearimgs designed for ao FcPerp value of the 1 -34 lb .2051 Ib 3 2- 2 -IS 826 3.50" I. so " WER 2.4 DFL STANDARD Iesser of the tress chord lumber value or E -85 lb 4 3- 7-12 678 3.50" 1.50" let• (creep factor) = 2.00 625 for all bearings. 3 -20 lb -568 Ib S 4-11-12 215 3.50" 1.50" IRC/IRC truss plate values are based on Refer to Joist QC Detail Sheets for 4 -38 Ib -464 Ib 6 6- 3-12 320 3.50" 1.50" 7 7- 7-12 348 3.50" 1.50" testing and approval as required by IBC 1703 Cq factors and Rotational Tolerances. 5 -15 lb .93 lb 88-11-12 218 3.50" 1.50" and AN I/TPI and are reported in ESR -1118. Install interior support(s) before erections. landed for 10 PSP non -concurrent BOLL. Mark all interior bearing locations. 6 7 -21 Ib -168 Ib -22 Ib -190 Ib 9 lo- 3-12 1418 3.50" I.SO" 10 11- 8- 0 1969 3.50" 1.50" PCrnuanent bracing is required to Overkpaann�� requires support at the location(s) B 9 112E /b -60 16 Ib Ib MAX DEFLECTION (pam):u pprevent rotation/toppling. See BCSI and ANSI/TPI 1. imdicaied. Support design is by others. Building designer shall verify gable loads 10 .331 -69 .1466 lb -1415 Ib 55 L/899 MEM 0-0 (LIVE)PLATING BASED ON GREEN LUMBER VALUES. and Cave loads, if applicable. HORIZONTAL REACfION(S) : L= .0.17" D= .0.7411 T= -0.40" EX. WB DBS C9;T= :L/120 + + + + + + + + + + + + + + + + + + + + + + Designed for 6.3 l lbs drag load applied I+) gable bracing regofired # 42" intervals, if egoaed to wind load applied to face. support support 1 -2182 lb 3 .2603 Ib IN MEN 18- 8; T= 0.02" -__ ] L-tim = horizontally in either direction to the top See 's Gable Bracing Details. support 4 1346 lb 721 Ib •let i o- o- a a 0- 0- 0 chord panel points, with dead + 0 % live loads land duration 1.60. This truss is designed using the ASCE?-10 Wind Specification support 5 6 721 Its z a- 1-I2 10 a- 7.12 3 tZ a 4-11.1z nasi = Continuous horizontal reaction = n8 RI Enclosed = Yes, d8 s rt sport uppo 7 721 Its 6. 3 4 e• a -u 1z B- 3-tz 541 PIf Max. Correction by others. 7rvse Location Not End Zone support 8 TEl Ib 5 7- 7•a 13 7-7.12 ++++++++++++++++++++++ Bur Category = C support 9 -693 16 6 8.11-1z a 8-11-1z 7 10- a -I2 15 ie- 3-12 light Over (s) are not to be removed. Bldg Length = 6S.08 ft, Bldg Width = 72.33 It support 10 177 Ib 8 11- 7 -IL 1e 11. 7-ta CRITICAL IMMEN FORCES: C COMP. DUE• / TESS. Ut. Cbl 0 6(S) Y BE SHORTENED UP TO 3" MAX.t 92184th Right Overhang Soffit loading = 5.0 psf Not designed for Mean roo height = 11.95 ft, mpb = 110 F Occupancy Catefor II, Dead Lad = 13.2 psf Designed Ra ;led Force Resisting System 1.60 / 5091 1.80 O.N attic storage unless noted otherwise. u n -Low-rime and Components and Cladding Ill•5071 L-3 •MBB 1.60 / 3578 1.80 8.50 3-4 -Leas 1.60 / L855 1.60 O.EB Tributary Area = 43 sgft 4.s •2073 1.60 / 2093 1.80 O.LI Vertical members exposed to wind: 16- 8 5.6 -1305 1.60 / Mau 1.e0 0.13 ea -577 1.60 / saw 1.60 0.14 Tress deli to support 1-0-0 top chord omtlookers 7-8 -321 1.80 / 408 1.60 0.80 8.0 •loo 1. as / 4 1.90 0.a and clad load not to exceed 10 PSP one face, and 0-0 -60((1.60 / a• /.ss 0.26 1 2 3 4 5 6 7 8 24" s opposite face. Top chord mast not be cut or rose�o4(i soli "Mi(i I no ed. e�io W o 400 to 11 / o.0z 11.12 / 0.01 I11 -/3a / 00..0101 -L / 14.15 / 0.01 IB -OB -161(1.60)/ 261(1.60) 0.04 4X4 2 R1 CORP. DUE. / TIXS. DN. ISI / 6X6 2.10 -792 1.80 820 1.60 0.20 1.11 .178 1.60 / 88 1.80 0.03 81 4111E -100 1.80 / 192 1.80 0.08 5.13 -326 1.60 / 211 1.60 0.07 6-7-14 6_11_12 6-14 -197 1.so / eP 1.60 0.w SHIP 7-15 -ta96 1.60 / 1488 1.60 0.47 Tae -1ea1 1.as / a1B 1.60 0.26 3X4 4 6 9-16 11713 /.Ls / 719 1.80 0.18 3X12 2 0-3-13 3X6 6x614 -o-9 T. �F�. J 9 10 11 12 13 14 1 6 No. C 72160 )` TYPICAL PLATE: 1.5X3 OVER CONTINUOUS SUPPORT f r �� CALaFC� connector plates are ALPINE Wave 20 ga., unless preceded by "H' for High Strength 20 ga.. "S' for Super - - - - - - - - - -5/6/201 Strength 18 go. Plates are to be positioned per Joint Detail Report. Circled pNates and false frame plates A A c= are poslhoned as shown above. Shift gable stud plates to avoid overlap with structural plates. 5I6I2O 1 V 268 - Homewood ss "WARNING!" READ AND FOLLOWALL NOTES ON THIS DRAWING! Cast: LEWIS WLLLIA)1.S (CA) wwIMPORTANT'' FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. DIB: Drive_M_0220316_IA0007rJO0001 require a rtuim. care in fabricating, handling, slipping, installing and bracing. Refer to and follow the latest edition of SCSI (Building Component W0: Drive_M_0220316_L000 Safety Information, by TPI and WrCA) for safety practices prior to performing Nese functions. Installers shall provide temporary bracing par BCSI. Unless Dsgnr: AW #LC = 57 WT/PLY: 97 v VT,usses ry no ted otherwise, We chord shall have properly attached structural sheathing and bottom chord shall have a property attached rigid ceiling. Locatians shown for lateral hs have bracing installed B3.87 X10, Appy to face truss TC Live 20.00 LiveSnowDur L=1.25 P=1.25 D ��� (� (1 lU�\vl I restraint n we shag per Cher sections or position as shown above and on Na Joint Details repon, unless noted otherwise. Wan as shown as applicable. plates each of and psf TC SrtnW P 0.00 8f (f SnoWDur L=1.15 P=1.15 Alpine, a division of ITN Building Components Group Inc., shall not be responsible for any deviation from this drawing, any failure to build the puss in TC Dead 14.00 psf Rep Mhr Bad / Comp / Tens AN ITW COMPANY conformance with ANSIRPI 1, or for handling, shipping, installation 8 bracing o1 trusses. A seal on this drawing or coverpage listing this drawing, Indicates acceptance of professional engineering responsibility BC Live 0.00 psf 1.00 / 1.00 / 1.00 7870 N. Greer SIN Pkwy. Grand Frain., TX 75050 solely for the design shown. The suitability and use of this drawing for any structure is the responsibility of the Building BC Dead 8.00 psf 0. C. Spacing 2- 0- 0 Designer per ANSI1TP/1 See.2 TRUSPLUS 6.0 VER: T6.5.20' For more information see this job's general notes page and these vreb sits:--- .. Bldg Code: CRC -2013 TC: L/240 ALPINE: ' TPI: ' WTCA: ' ICC: g DBPL RATIO: L/240 Job Name: SINGLE FAMILY RESIDENCE Truss ID: M11G Qty: 2 BRIG 1 -LOC RFALT SM 1 0- S. 1 249 10.12" a -D 1.50^ TC Zx4 DPL I1 A lir. IC zx4 DPL 41 i ltr. DesIred pee ANSI/TPI 1-2007 Pabr DPLXFT RUMON(S) r z eH-11.8 Z04 1.Sd' 09 3.30" 1.58" 1.60^ BILL CUD Zx4 DPL STANDARD canes Toleraoeo = 20.01 Benrings designed fir an PePaarrpp vales of the Support CAC T Nos -Wind 1 •34 Ib 3 8. 8.18 4 8. 7.12 888 8.50" 1.90" WHl Zx4 DPL STANDARD HQ (creep factor) = 2.00 leaser of the truss chord lumber value or 088 for all bearitgs. 2 -85 ib 8 -EO 11 5 4-11.12 714 3.90' 1.80^ lRC/� truss plate values are based or Rehr to Joint OC Detail Sheets fbr 4 -38 lb e o- 3 1 I54 sago I.so" teatlI�t�g ani approval as required by lK 1703 Cq factors and Rotational Tolerances. 9 -I9 lb 7 7. 7.18 101 3.60' 1.80^ sed ANSI/TFI sed ate reppo�rted in -1118. Loaded for 10 PSB ma•coacarrent /CLL. 9 •81 Ib 8 8-11-Iz 191 3.80" B l0. 8.12 1B8 8.90' 1.80" 1.80" Mall interior sf�port(s) before erection. fro Mark all interior bearing locations. 1 .22 Ib IB ll- 0- 0 693 3:30" 1.60^ Aeraaeeat 6raclog rreeqguired to peves t re It Bee Oveerrphasyt�g rqulres "%port at the locatloo(s) iodlcaied. Support design Is by others. 8 •8E Ib 9 -BB Ib -187 Ib Ka MLRCTION (seppaann)) t 6- -14 1.5X3 /CBI am ANSI/iPI 1. Building designer shall verify load. 10 831 16 L/999 ON 0-0 CLIVI) LC 63 •115 1.01 / 150 1.L1 0.00 PLATING IAM ON ORB>ml LllMM VALDBS. gable and rave loam tf 1110232 MAL RBACIZON(S) I. 0.17 D. 0.Z4" To •0.40" EX Wl DRF CR1T11MsL/1Z8 Ri t Overhau�(s) are not to be removed. applicable. 1�] gable bradsg seabed a 42" Intervals. t support 1 145 ib IN 1091 18. 8: T. 0.02" 04R®M10(S) MAY RR SHORYIIED OP TO 8" TIAL 1 IP exposed to a ad.lGad applled to fbee. support 3 145 Ib ® Jolat_tauttam lit Overhang Soffit loading . 5.0 prof No designed i17' attic storage unless See 1TW3CG'e Cable haciog Details. This tams is designed ming the AMI -10 Tied 1.9 Ification It 1.2 owl / T2118. ham. ra[ •E88 I.BG / 40 I.Za O.M Cast: LMS WELILL BS 2•t 9.4 •LlM1 I.BD / 40 1.25 0.07 -aaa 1.4o / M 1.Z7 0.03 - 4.11 •1116 1.60 / Y I.Za 0.01 WO t Drivel 0220316_1.000 - 5•e 4.7 r.s •100 1.60 / M 1.25 1.Oa •104 1.60 / 40 1.25 0.09 •eE7 1.60 / ta7 saes ease Dagar t AW 9LC - SS W1'/PLY: 95 6.0 0.0 loo Las / 4 I.ao 1.68 •e0 1.60 / roe 1.78 6.46 1 2 3 4 5 6 7 8 10 X106 Las�i 145(1 W) 005[ 4r 00 10.11 11.112 / e.al / 6.01 IC Snow (Fo 0.00 paf 11.12 / 0.01 ut Alpine, a an sicn of ITV SuUOog Components Group Ina•. nog not be reepmsalo tor any deviation from mh arawvrg, any faorre to build the buss In Ce^lormano wM ANSVTPI I, cr fw rernny, sbwnO• Int bdon a bracing of eutsec 15.14 14-15 / 0.01 / 0.01 AN (TW COMPANY 2820N.G-I1SWPkwy.Grs,wi1alrf4T)(7WW la -le / 5.01 1.00 / 1.00 / 1.00 16-0 / 0.00 RC Dead 8.00 psi IS OW. / T"'S. roan ea[ 1:5X3 IS •no I.a3 / 5e I.Oa o.oa 2.5X4 x•11 -21.115 / e I.W 4.41 1.5X3 4.111 s•0 .las Las / le Lao 1.111 1.115 / Is 1.w 0.02 6- -14 1.5X3 6.11 •140 •140 sass / e Las 0.03 1.5X3 1. Is •115 1.01 / 150 1.L1 0.00 1.5X3 7.16 -1 1.61 / 121 1.25 0.05 1.5X3 1.16 -716 1.110 / no L10 gaga 3X6 S 0-3-13 1.5X31.5X3 1.5X3 1.5X3 1.5X3 2.5X4 4X4 OVER CONTINUOUS SUPPORT All connector pates are ALPINE Wave 20 ga.• unless preceded by 'H' for High StrenpN 20 ge., for Super afire Itlategd as stawn plates abovalse ee pS "ft g�Me�saW�pletes toll Red overlap with sed ttesructural fp�fs. Itiun = Not Had Zone bC = 08.09 ft, lld8 width = 72.88 ft height . 11.95 R. wmb 110 Ca 11, Dead Load 13.2 psP s Main Tiod Force Resleti SYwte e and Cospoweats ad Clad Area = 48 sgft ambers exposed to wilt 18. 8 Toms designed brt 1.0.0 top chord ontlookers and cladding load not to exceed 10 FSP one face, and 24" span opposite face. Top chord must not be tut or mtckted. B2 6.1 -12 SHIP 416 � i lA, Approved Py Streamli En ing Date: No. C 72160 5/11/2016 WS - Homewood Tru -WAKIVIN(al `" READ AND FOLLOW ALL NOTES ON THIS DRAWING! Cast: LMS WELILL BS (CAI "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS. DIR: Drive�0220516 LID9007_J00001 /\ emmcare Trun reamre ae In fabricating, nenmina, Shlppfng, barreling and bracing. Refer to ena Wm the aura nation m mpanent SCSI (Building Ca WO t Drivel 0220316_1.000 - Safety wormeuon, by TPI and MCN far relay, precucea vim' m pwfomdrg ewer hmc0wrn trutman slue p -W. t..gm y bred"g per SCSI Unlno Dagar t AW 9LC - SS W1'/PLY: 95 n, noted atheraiee, top chord Shell love pmPory attached sllucorel sAwthirg end eastern Burd shall haw a "Milt' attached dgfd cegrg. LocNom shown TC Live 20.00 psi LiveDar L=1.25 P-1.25 yf ^ n m acarol ash �d of webs ebml t� tuna ea pm acs/ oocgom B3.87 m rho. as epplcnblo. appy pates a oath rata a buu and farpa IUB\\I d II I`� 0 poamn as crown shwa and nipo t ids.. ma doom Wings report umao mese olbenrue. IC Snow (Fo 0.00 paf SnovDor L -1.1S F=1.13 1� II ut Alpine, a an sicn of ITV SuUOog Components Group Ina•. nog not be reepmsalo tor any deviation from mh arawvrg, any faorre to build the buss In Ce^lormano wM ANSVTPI I, cr fw rernny, sbwnO• Int bdon a bracing of eutsec TC De 14.00 f Ps Re Hbr Bad / Co / Teas F aP AN (TW COMPANY 2820N.G-I1SWPkwy.Grs,wi1alrf4T)(7WW A seal on this dnewing or covarpege Naf/ng this dntwfng, lndicetes seeapf ma of profssdonal en lne&ing rssponsibfilty for the des/ggn The this drawing for is RC Live 0.00 psi 1.00 / 1.00 / 1.00 solely shawn. sultsblllty and usa of any structure the responsibility of the BUllding Designer per ANSYM 1 Sar -2 RC Dead 8.00 psi O.C.Spaclag 2. 0- 0 TBUSPLIIS 8.0 V101: T6.5.20- Pw mo a mrwmn on Cee the pb s psnand nates pogo and main web wee: ALPINE: �7P1: WTCII• ICC: Bldg Cade: CBC -2013 DEFL RATIO: L/240 TC: L/2401