Loading...
HomeMy WebLinkAbout069-200-00469-20-04 92-518 BPEM MIMNAUGH, John & Helen 91 Kokanee Dr, Oroville cont: Better Builders (new sf) eq,,1Q;9y B08-0995 SCANNED 069-200-004 MISCELLANEOUS Re-Roo REROOF W/ COMP 29 SQ 91 KOKANEE DR MINNITI, ANTHONY SR S I � RESIDENTIAL 69-20-04 92-518 BPEM -� i MIMNAUGH, John & Helen 91 Kokanee Dr, Oroville cont: Better Builders (new sf) 0A, OFFICE COPY i Address i J y � ,i =-BY Date ELECTRIC Metl ter By Date — _A—J JOB FINALED (Date) Signature _1�1�1p�,/Jf J=OK O Not OK = Not Applicable ' = Not Ready MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Soils; Special MH Support Sketch 3. Sewer; Location -Test -Fall -C/O Concrete 4. Water; Location -Test -Easement Needed (Sketch) 5. Electricity; Location -Clea rences-Grnd-/ /Amp -Concrete 6. Gas; Location -Test -Wrap: / /"L"ft. / /"Nat. or/ /" L" ft./ /"LPG 7. Well Clearance & Disconnect 8. Utility Clearance Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks Easements 2. Footings; Size -Spacing -Marriage Line 3. Gas; MH Test -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances 5. Drain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval 8. Gas and Electricity Tagged 9. Exits; Insp.-Sketch 10. Cert. of Occupancy Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES, (Plans)OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Griders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rftrs.-Connectors Shthg.-Rfg.-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg; Sils-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings Date Card B-1 Date Card B-1 "Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distances-GFI 5. Elec.; Pool Lighting; 15 volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. _ Boxes-Enclosures-Panelboards-Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 ✓=OK O=Not OK =Nieplicable Not Ready RESIDENTIAL (; = Date UNDERFLOOR (Plans) OK except ft's J,4" -zoning -setbacks -Easements -Flood -Slope Fig., Main; Soils-Elec. Grnd.-4&' Ftg. Depth Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth 4. Ftg., Porches & Decks; Soils -Steel-/ /Ftg. Depth tStemwalls, Main; Steel -Bloc kouts-Wrapped � temwalls, Garage; Steel-Blockouts-Wrapped 6a. Hold Downs and Special Anchors 7. Slab; Steel -Wrapped 8. Piers -Fireplace Ftg.-Steel D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 10. UF. Gas Pipe; Size -Anchors - yard gas piping: size -test 11. Water Pipe; Test -Anchor -Regulator -Service Test 12. Electric; Underground 13. Pienums & Ducts; Clearance -Material -Support -Ins. 14. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples 15. Access & Ventilation 16. Insulation Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PLUMBING (Permit),OK except 4's 16. Water Htr.: Vewf-Access-Cemb rMterr-A++-Baffle 7. Water Pipe: Test & Anchor -Nail Protection tXB. D.W.V Test-Fittinqs & Anchor -Nail Protection 19. Shower Pan: Test. First Floor -Tub Access _-- 20. Test Tub & Shower, Second Floor -Tub Access -------- --- 21. Gas Pipe: Size & Anchors Date ��/-- B_1 -Date - -- ___Card B-1 Date Y Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except ti's , 22. Fi ture & Transformer Clearance -Ins. Protection --------------- - - - - --- - Elec. Receptacles Spacing -Lights &Switches at Doors ---------------- ----- ------------ 24. ize Boxes & No. of Conductors -Stapled --------- -- -------------------------------- ------------------------ G?S-Romex Installed Close to Edge of Studs & C.J. -- - ----------- -- 6. quip. Ground made up w/Meth. Fastners-Bond Gas & Water ------------ ----------------------------- ------------------------------- �2 Appliance Circuts in Kitchen &Conductor Size --------- - - - ------------------------------- ---- ------------- -- 28. Subfee Wire Size / r ga. Cu or AI A. ire Size // ga. Cu 29. Range Circ. / J ga. Cu or AI- ven Circ. /t ga. Cu oAI Insulated Neutral Yes ❑ No - - ------------------------------------------- 30. Service -Riser Conductors & Ground -Main Disconnect ------------------------------------------------------------------------------- 31. Equip. -Clearances Panels-Motors-Mech. Equip. i2 Clothes Closet Light -Shower -Light -Spa Light L38 --Smoke Detector ------ --- -------------------------------- --------------- ------------------- Date �c 9�Card 6_1 lyd Date Card B-1 Date Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except a's A.C. Ducts Insulation & Support ---------------- - -Vent Fan: Exhaust above insulation ✓36. Condensate, Drain & Overflow: Size & Grade ��---------------------------- ----------------------------------- 37. Furnance-Vent: Access -Comb. Air -Return Air Vent -115 outlet ----------- -- - -------------------------------------------- - - 38 Attic -Access-&- Platform if Furnance in Attic ------------------------------------------------------------------------------------- -- ---- -- - - - - - - - -- Date 6and B-1 Date Card -B-1 ----- zy y ------- ---- ------------------------------------------ Date Card B-1 Date Card B-1 Date FRAMING (Plans) OK except h's PK Sils. Proper Material & Anchors ------- ---- --------------------------------------------------------- Walls Studs _Nailing_ Spacing & Bracing -Plates -Sound ----- -------------------------------------------- 41. Bearing Walls over Girders &'Floor Nailing ----------- 42. Draft Stop -Walls (rat proof) 621"Fire Stops: Furred Ceilings -Stairs -Chases -Tub -- =-------------------------------------------------------------------- / Headers & Beam -Size & Bearing "Ingle & Duplex) ' Date FRAMING (Continued) 4 Hangers -Post Caps -Anchors -Connectors - 4 Ing. Joist-Rftr. 'es -Pur m roof Brac?ru*Shthng.-Rf _ Fireplace Ties or Type A Flue -Fireplace Throat clearance Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles _ �9'Bdrm. Windows or Exiling Doors -Sill Hgt. & Dimensions _ _ 50 Garage Fire Protection Framing 51. -Property Line firewall & Openings _ Ext. Doors -One 3' -Check Garage -3rd Story. 2 Exits _ t�e3'Stairs Width -Headroom -Rise -Run -Landing -Fire Protection 54. plywood on Roof Overhang -Attic Vents -Rafter Outriggers ling -Nailing Veneer --------_-� cco Mesh -Drip Screed -Fd. Vents-Underflr. Access 46 . Glazing Area -Glass Protection -Skylights- Plastic 58. Shear Walls; Nailing -Bolts 59. Insulation -Walls -Ceilings 60. Infiltration -Walls -Windows DatB-Date Card B-1 Date P� Card B-1 Date Card B-1 Date FIN (Plans) OK except ti's Steps -Door & Sidelight Protection -Landings ------------oke Detector 3. Furnace; Vents -Clearance -Comb. Air -Connector - _Garage; Above Floor -Ducts -Meth. Protection l!6.e_droom_Exiting 5. F.I. & Bath Fixtures & Tub Access -Spa 1 ---------- -------- _ 6 Elec. Trim & Subpanel; Breaker Sizes & Labels - - --- lairs & Rails --_--- _ _ d/Fir�fllace or Stove Clearances -Hearth hit EIc Outlets at Wood Panel Int. & Ext. Ki Fixt. -- &Appliance; Grnd.-Air Gap -Cooking Clearance ------ ------------------ Elec. Outlets & Receptacles at Kit. Counter ---- 7 ara re Door: Swing -Landing -Closer - - A.C. Duct in Garage -Damper 7 HtrHtr. 'Vents -Clearance -Comb. Air-Connector-P.R.V. Rr6erage: Above Floor-Mech. Protection 7 b.. Elec. & Mech. Equip. Listed for Location -----_--- 7 15ec_-Receptacles in Garage: (G_F.I.)-Romex Protection „7:�15rtla 6n -Foam -Looked in Attic ❑ Yes ------------------------- ------------ - uard Rails & Deck Construction -Post Caps 71Pq' Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floav, ❑ Yes 80. Following instl: rive Yes ❑ No; Walks.es ❑ No: Planters - Ey'Yes -IF), No ---_- "5V Stuc-o; Brown -Finish ------------ ------- --- __ __ _ __C. t: Disconnect. Electrical, Plumbing ents Above Roof; Plbg -Appliance-fireplace.-Clearance to Openings B O�I'I isconnect, Electrical, Plumbing - 8 erior Ii ec. Trim; G.F.I. Receptacle -Underground - - ------------ ---- Yomilation Throughout House te-Glass Protection -- - - - ---------------------------------------- 88. -------------------------------------88. Corrections from Previous Inspections _ ----------- --------- - - ----- - - - --------------- 8 Tesi Meters Tagged,f_4s-645ris _______ W;�ater & Sewer Connected -C/O to Grade -HD Approval - 9 nergy Compliance Certificate -Other Certificates Date %,b )Ea rd B-1 Date _Card B-1 - Date Card B-1 _Date Card B-1 S------------`�" Date Card 6-1 Date Card B-1 Comment at Final: CERil'FICATEOF .,\)TE OF Twee ? o r a A' c W _H S O a T -C x CONFORMANCE IH5 UNDERSIGNED MANUFACTURER HEREBYCERTIF/ES that the products identified below and on attached sheets Nos. are marked with the Collective Mark of the AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (AITC) and were manufactured in conformance with applicable provisions of American National Standard ANSI/AITC A190.1-1983, Structural Glued Laminated Timber, and that such manufacture has been at our plant in_____ Riddle, Orenoci , which plant has a quality control system approved by the Inspection Bureau of the AMERICAN INSTITUTE OF TIMBER CONSTRUCTION and inspected periodically by such Bureau. The manufacture of these members complies with the manufacturing and fabricating provisions of Chapter 25 of the Uniform Building Code. 1 JOB NAME: JOB LOCATION: RpHili ng, rA ',. CUSTOMER'S ORDER NO. 14167 DATE 5/7/87 MFGR'S ORDER NO. 13766 Members have also been manufactured to the mare restrictive provisions o f� P.S. 56-7-73. SIGNATURE �� L�`'t%-�Zd�'/'4'�-"'� COMPANY Riddle Laminators TITLE,Qllall fy Control ADDRESS Riddle, OR DATE _ -5/20/87 A/TC HEREB Y CERTIFIES that the said company at its said plant is licensed by the AMERICAN INSTITUTE OF TIMBER CONSTRUCTION to use the AITC Collective Markin respect of products which comply with applicable provisions of said Standard, that the adequacy of the quality control system in effect at said plant is periodically inspected and verified by the Inspection Bureau of the AMERICAN INSTITUTE OF TIMBER CONSTRUCTION, and that, in the judgment of AITC, said company is capable of complying with applicable manufacturing and testing provisions of said Standard in respect of products manufactured at said.plant. Conformance with the Standard in respect of any specific or particular product is the sole responsibility of the manufacturer; AITC's guarantee hereunder being that the said company is qualified to produce a product meeting the said Standard and that its plant is periodically inspected and verified by the AITC Inspection Bureau. AITC FORM IBCA AITC Cerli/icale No. 371.22 A AMERICAN INSTITUTE OF TIMBER CONSTRUCTION KFS Gn �R' SA�}S P 1983 AMERICAN INSTITUTE OF TIMEIER CONSTRUCTION Owner:. M l mmmh Permit No. ENERGY CERT it l /<,o/gh e e r-, I'Dro IF ICAT ION LOCATION A.P. No. »' DESCRIPTION OF INSULATION ROOF Material Brand Name Thickness(inches) Thermal Resistance (R Value.) EXTERIOR WALL Material Z - 19,, re ala Ss b t 1145 -Brand Name Thickness(inches) Thermal Resistance(R Value) CEILING Batt or Blanket Type V-32 Brand Name Thickness(inches) Thermal Resistance(R Value) Loose Fill Type -39 Brand Name Minimum Thickness(Inches) Number of Bags Wt. per bag lb. Area covered(ft.2) Thermal Resistance(R Value) FLOOR, ELEVATED Material J', Fibe=1455 %2 5. Brand Name Thickness(inches) Thermal Resistance(R Value) FLOOR, SLAB MaterialBrand Name Thickness(inches) Thermal Resistance(R Value) Width(inches) FOUNDATION WALL Material Brand Name Thickness(inches) Thermal Resistance(R Value) I hereby certify that the above insulation was installed in the above building in conformance with the State of California Energy Requirements. ,Zoel- ee sl��4�iovJ� l�iC. FIRM NAME / OWNER SIGNAT E W INSTALLATION APPLICATOR -,/ 4416-0 STATE CONTRACTOR'S LICENSE NO. 8-ao-9z DATE I hereby certify the above insulation and all required items as shown on the Building Department approved plans and attachments have been installed as required by the State of California Energy Requirements. All equipment, devices and materials are of the quality prescribed or are specifically approved by the State of California. Be#ei I a;)d r -s &04 St FIV NAME/OWNER (Please print) SIG F UENERAL CONTRACTOR/OWNER STATE CONTRACTOR'S LICENSE NO. F- -z o - 9 z, DATE THIS CERTIFICATE MUST BE ON FILE WITH THE BUILDING DEPARTMENT PRIOR TO FINAL INSPECTION APPROVAL AND A COPY SHALL BE. POSTED WITHIN THE BUILDING. January 1984 COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 1469 Humboldt Road, Chico, CA - (916) 891-2751 7 County Center Drive, Oroville, CA - (916) 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 CORRECTION NOTICE OMER PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If ou have any questions pertaining to this matter; or need additional explanation, pleasVcont;Z his office immediately. fAe JIL41(ee AJ -r—W L I— kagL�gf- Date 7 Inspector REV 11/91 f _ r NTY F BUTTE COU OJ DEPARTMENT OF PUBLIC WORKS 1469 Humboldt Road, Chico, CA - (916) 891-2751 7 County Center Drive, Oroville, CA - (916) 538-754_1 747 Elliott Road, Paradise, CA - (916) 872-6307 CORRECTION NOTICE OWNER PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please ntact this office immediately. �^ z �r 7 H- r — /L r 'J'11 i M Date L__ Inspector REV 11/91 COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 1469 Humboldt Road, Chico, CA - (916) 891-2751 7 County Center Drive, Oroville, CA - (916) 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 CORRECTION NOTICE OWNER PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to is matter, or need additional explanation, please contact this office immediately. s Date G} Inspector Aly - REV 11 1 COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS PERMIT NO. 7 County Center Drive - Orovllle,Callfornle 95965 - Telephone: 916,'538.7541 R� S APPLICATION AND PERMIT ASSESSOR PARCIEL NUPIER 69-20-04 ZONING RT 1 BUILDING PERMIT OWNER JOHN & HELEN MIMNAUGH 510 TELEPHONE 483-5417 SQ. FT. OCC. BUILDING V UAT N 2350 R 119,850 OWNER'S MAILING ADDRESS 2283 W IMBLEDON PL SAN LEANDRO 94577 1011 M 18,198 CONTRACTOR'S NAME BETTER BUILDERS TELEPHONE 331 C 4,303 CONTRACTOR'S MAILING ADDRESS Fireplace I "A" 1,500 CONSTRUCTION LENDER UNKNOWN Total Valuation $ , Filing Fee $ 15.00 LENDER'S MAILING ADDRESS Permit Fee $ 751.50 ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ 375.75 Energy Plan Checking Fee $ 20,00 ARCHITECT OR ENGINEER'S MAILING ADDRESS Penalty $ BUILDINGADDRESS KOKANEE DRIVE OROVILLE Permit fee $ 1162. 25 PLUMBING PERMIT Filing Fee 15.00 Each Trap 131 5.00 65.00 Solar or heat pump water heater 1 20.00 LOT 30 SUKELLEY RIDGE ESTATES UNIT 3T43ARCEL444MAP Water piping 7.00 7.00 Each qas water heater or vent 1 7.00 USE OF STRUCTURE SF t Duplex❑ Mobilehome❑ Other SPECIFY Gas piping system 1 - 5 outlets 1 5.00 Building sewer 15.00 15.00 Mobile Home S I G I W 615.00 TYPE OF WORK New LX7 Addition ❑ Remodel ❑ Utilities ❑ Installation❑ Other ❑ Describe work: 3 BDRM _ Permit Fee $ 102.00 Contractor ELECTRICAL PERMIT Filing Fee 15.00 Main service 200A OR LESS 1 18.50 Main service 200A TO 1000AI 1 CONTRACTORS LICENSE LAW I declare r penalty of perjury (Check One): I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and �iy license is in full f e and effect. License ;Jo. ��J Classification :17 ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONST. ( DWELLING OCCUP.A� OR ADDNS. 1 ACC. BLDGS. _37.50 3.50 sq.ft. 7 GVQ NEW CONSTR. ULTI.OUTLET NON•RESID BRANCH CIRC ITS @ 5.00 POWER APPARATUS .&) (SINGLE OUTLET CIR. ) Ex. Occup(OUTLETS OR FIXTURES 20 760 A Ex. Occup. OUTLETS ((RESID )RE 3.00 Temporary service 15.00 Mobile Home Facilities 15.00 Misc. Wiring g 15.00 Permit Fee $ - WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The It is for $100.00 (valuation) or less. ave placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Contractor MECHANICAL PERMIT FiIingFee 15.00 Heating 9.00 HEAT PUMP Cooling 4 TON 16.50 Hood 6.50 6.50 Ventilation 4.50 pernit Fee $ 51.50 Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against id C my ' c e .nee of the granting of this permi X Date Signature of Applicant - OwnerElContractor ElAgent An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories i eight. Mobile Home Installation Fee $ Ener Inspection Fee $ Energy p 40.00 00C_ cory�Try CC TOTAL FEE $ 1,506.85 HAz OFEE MP - FLOOD ✓ COF -_ PAflC�1r j/ PD IS U This per is hereby issued under the applicable provi sions of the Butte County Code and/or resolutions to do i work indicated above for which fees have been paid. _Dt OF PUBLIC WORKS Date! Z-,- IT EXPIRES Date P�i Receipt No. 110009 %�/ i WHITE -O. P.W„ YELLOW -ASSESS R, PIN R -INSPECTOR, GOLDENROD -APPLICANT I COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS PERMIT NO. F 7 County Center Drive - •rovllle, Callforn;a 95965 - Telephone: 916.'538-7541 APPLICATION AND PERMIT A 93ESSOR PARCEL NUMBER j ZONING Q BUILDING PERMIT OWNER 5/O TELEPN E SO. FT. OCP. BUILDING V UATION J a ttJU UL l U 3 �� OWNER'S MAILING ADDRESS 77 CO �AC,TOR'S N/SME I ^�� TELEPHONE DONT AACC'TT(ORR'S MAILING A[DDDRREES5 CONSTRUCTION LENDER LENDER'S MAILING ADDRESS ARCHITECT OR ENGINEER ARCHITECT OR ENGINEER'S MAILING ADORESS BUILOINCyy1GDR E55 UNKNOWN LOT NO. SUBOI V151 N NAME PARCEL MAR^ USE OF STRUCTURE SF Duplex❑ Mobilehome❑ Other SPECIFY +11/ TYPE OF WORK New Addition ❑ Remodel ❑ Utilities ❑ Installation❑ Other ❑ Describe work: 3 612,4f 4W CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): ❑ 1 am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License ;Jo. Classification J I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. Business and Professions Code for this reason Fireplace I rYA / IEZ6G_Total Valuation Filing Fee Permit Fee Plan Checking Fee Energy Plan Checking Fee Penalty Permit fee PLUMBING PERMIT Each Trap Solar or heat pump water heater Water piping Each qas water heater or vent Gas piping system 1 - 5 outlets Building sewer Mob le Home 1 S I IS JW Permit Fee Contractor ELECTRICAL PERMIT Main service 600VORLESS 200A OR LESS Main service 200A TO 1000A, NEW CONST. ! DWELLING OCCUP.✓41 OR ADONS. 1 ACC. BLDGS. I NEW CONSTR.MULTI-OUTLET NON.RESIC, BRANCH C`RCUITS) POWER APPARATUS e SINGLE OUTLET CIR. EX. OCCUp(OUTLETS OR FIXTURES FIXED APPLNS.OR Ex. Occup. OUTLETS (RESID.1 EA.) Temporary service Mobile Home Facilities Misc. Wiring Permit Fee Contractor $ 15.00 $ 57,s $ 3 7S, 75- $ „2p 5 $ ,e2 Filing Fee 15.00 5.001 6S,OG 20.00 7.00 7, p6 7.00 5.00 15.00 @ 15.00 $ Filin ee 15.00 18.50 ; 37.501 3.64 sq.tt. @ 5.00 1 3.001 1 15.00 15.00 15.00 I $ 1 fluza WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): MECHANICAL PERMIT Filing Fee 15.00 Heating r0 O ❑ The permit is for $100.00 (valuation) or less. E] E] I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. Cooling rs I Hood 6.50 ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. I Ventilation Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Permit Fee ; Contractor I certify that I have read this application and state that the above information Mobile Home Installation Fee $ is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Ins Energy Inspection Fee $ 4e1 DCC CONST TYPE TOTAL FEE$jf I Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against HAz 0FEES IMP FLOOD CDF PAR PO D ISSUE all liabilities judgments costs and expenses which may in any way accrue against said County in consequence of the granting of this permit. X Date This permit is hereby issued under the applicable provi- Signature of Applicant — Owner ❑ Contractor C Agent ❑ sions of the Butte County Code and/or resolutions to do An OSHAwork indicated above for which fees have been paid. .on of structures over 3 stories .n height. permit is required for excavations over 5'0" deep and demolition or construct- I DIRECTOR OF PUBLIC WORKS By Date Receipt No. ! (1UU I PERMIT EXPIRES Date t •- \'Ck•''r (`� � � ti'1 i���'-..•. '�..'-r}. tib" 1i'-("Yv����y`)`.t't^.4+1 COUNTY OF BUTTE - DEPARTMENT OF.PUBLIC WORKS - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE: 916/538-7541 PERMIT APPLICATION DATA SHEET � . Permit No. OWNER N H CLE A,' /n / 11 1,1" 61G fV A. . 6,?— ;Zo -Ol/ Proposed Building Use �{�' Building Inspector Date At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: DATE RECEIVED APPROVED 1. All items have been submitted . .......................... -- . ...... ' * 2. Plot plans in duplicate/triplicate, signed by preparer of plans ....... . 3. Complete plans in duplicate/triplicate, signed by preparer of plans .. 4. Complete engineered plans and calcs, with wet signature on plans .. 5. Hazardous Material Form .......................................... 6. Energy Design Compliance and supporting documentation ......... 7. Statement of Intent for Non -Heated and AC Buildings .............. 8. Engineered truss details and layout in duplicate (required prior to plan check) 9. Mobilehome installation data including manufacturer's installation instructions....................................................... 10. Fees of $ ........................ 11. Chico Urban Area fees paid ....................................... 12- Park fees paid ........... 13. n u U 6 CESchoo District fees paid .............. � Z 14. Sanitation approval from Lofi �V� Health Department 2 15. City of Chico plumbing permit ..................................... 16. Plot plan and business license approval from City of (see City for other requirements) 17. Planning approval for (A) Use: (B) Parking: ...... 18. Improvements may be required. Contact Land Development Section DPW 19. Driveway permit (construction approval required prior to occupancy) 20. Pre -Inspection for required Pre-Inspec. request to Building Inspector (Date) 21. Contractor's license information (No., Name Style, Classification) ... 22. Certificate of Workmans Compensation Insurance .................. 23. Owner -Builder Verification (Given to owner ❑, Mail to owner ❑) ..... %Y24. Recorded copy of Agricultural Acknowledgment Statement ......... 25. Letter of signature ay� t orizatjp :(:9K3 6. Sff�G� i��r�. .. 6 0 lj/ Ov./�)..... Z -g }� 27. When you issue the permit, process as follows: Mail t owner. Mail to contractor. Telephone :rFc7-2_ 7y and hold for pickup at office. Deliver w/inspector. Other Applicant Date, Copy of Haz-Mat form sent Health Dept. Fire Dept. Air Pollution Date Copy of plans sent Health Dept. Fire Dept. C her Date . By The following data must be submitted pr 1. Index permit for above items No. 2. Additional items required: it issuance: (Circle new item not checked above). Contractor, designer, owner, was advised of above required data by_phone---mail_countP-r'by .date Contractor, designer, owner, was advised of above required data by_phone_mail_c^.rtinter by date Plans checked by Date Plans approved by—IL, y_I � l// Date Sets of plans on hold in File cabinet AP folder' Copy—DPW TO: Building Department FROM: Encroachment Permit Section RE: 'Driveway Clearance �`3.,l.�lL�/' �3ui <�.�s�f �l �oK�cr� 22 �✓' . , owner location AP #r Driveway permit f 2-0 has been issued for rthe above property. n b 2-z7-yz date sign/ ign re but not limited to cultivation, plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise, and odor. Butte County has established agricul- tural zones which have as a priority use for productive agricultural purposes, and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary farm operations. All that real :property:. situate in the County of Butte, State of California, described as follows: 30, U.h/!- 3 ke/l y IQrc e,c5f,ZfecS Sktbol/V!S/017 41->e?r(fGO�i�yiO�1/V Known as / c Date: PROPERTY OWNERS: State of) On this the j� day of Q/ 19 before me, the SS. undersigned Notary Public, personally appeared County of ) O , /I SING Personally known to me. D Proved to me on the basis of satisfactory evidence. o be the person(ss) whose name( ;i -i Q c l 4 -�'`- es ® tim ubscribed to the within instrument and acknowledged that executed the same for the purposes therein contained. IN WI ESS WHEREOF, I hereunto set my hand and official seal. Present A.P. No.T9- ab-aT---- Notary Public Q=mn ew fl(1P_BILImcwT 92-1099 Return to DPW AGRICULTURAL STATEMI M OF ACKNOWLEDGEMENT FOR RESIDENTIAL DEVELOPMENT Section 26-8.1 of the Butte County Code requires this acknowledgement be recorded prior to issuance of a building permit. 92-010929 1 Rec Fee 5.00 The property described herein is adjacent I Check 5.00 to land or included within an area zoned for agricultural purposes, and residents Recorded of this property may be .subject to incon- Official Records veniences or discomfort arising from the County of use of agricultural chemicals, including, Butte but not limited to herbicides,_ pesticides, Candace J. Grubbs I and fertilizers; and from the pursuit Recorder of agricultural operations including, 1:3Opm 13 -Mar -92 I PUBL XX 1 but not limited to cultivation, plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise, and odor. Butte County has established agricul- tural zones which have as a priority use for productive agricultural purposes, and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary farm operations. All that real :property:. situate in the County of Butte, State of California, described as follows: 30, U.h/!- 3 ke/l y IQrc e,c5f,ZfecS Sktbol/V!S/017 41->e?r(fGO�i�yiO�1/V Known as / c Date: PROPERTY OWNERS: State of) On this the j� day of Q/ 19 before me, the SS. undersigned Notary Public, personally appeared County of ) O , /I SING Personally known to me. D Proved to me on the basis of satisfactory evidence. o be the person(ss) whose name( ;i -i Q c l 4 -�'`- es ® tim ubscribed to the within instrument and acknowledged that executed the same for the purposes therein contained. IN WI ESS WHEREOF, I hereunto set my hand and official seal. Present A.P. No.T9- ab-aT---- Notary Public Q=mn ew fl(1P_BILImcwT S u3 rn LL: 0a io Q U� v1''..w%��.-:..�r-�t.�y..�wt�en1`,.�^"�r;.-,...fi^V.rvti-y'tlihlra✓ '4a...�;i ''Pf•i[a"s. ...+SSF '4 ^sf..,,r+... .,. ,. �. �A �..w,,. ,. .. BUTTE COUNTY -SCHOOLS DEVELOPMENT FEE CERTIFICATION FORM (One Form`per Building) A. P. Number 20 —c2C)Building Department No. School District 090 G L E114 City Q County Jurisdiction Property Owner ,1O (tit/ � /f �L �{iY� / /" A/� Project Location/Address g/D,¢'i¢�/ J7�, �%� Subdivision Lot Number, Residential Development: a Sq. Footage Z 3S # of Living MHI Addition (Group R) Units Commercial/Industrial: Sq. Footage New Addition (Including Exterior Roofed Areas) i 'Buil 'ng D partment Representative Date ******************************************************************* (Floor Plans reviewed by School District Personnel) District Id No. Applicant Name Street Address City) School District certifies that .� lJ, (Phone yy (State) Numper) Zip Code) has complied with the requirements of Resolution No. -Q by the payme t of $ 2,2451 Qp representing square feet. A chool District Repr23entative PAID BY CHECK NO. ,3 9 BANK NO PAID BY CASH Date white -applicant, yellow -building department, pink -school district SCHOOL.FEE (8/88) PERMIT NO: 13-92 Lake Oroville Area Public Utility District 1960 Elgin Street OROVILLE, CALIFORNIA 95966 533-2000 DISTRICT APPROVAL AND VERIFICATION OF INSPECTION BUILDING SEWERS This verification form must be submitted to the Butte County -Department of Public Works Building Department prior to issuance of a building or occupancy permit, whichever is applicable. Prior to final approval by Butte County of a Building or an Occupancy Permit, a copy of this verification form, signed off by Lake Oroville Area Public Utility District, must be submitted to Butte County. Date: February 27, 1992 Applicant: JOHN & HELEN MIMNAUGH (Better Builders Constr.) Applicant Address:Wimbledon - San Leandro, CA 94 Applicant Phone No.: (510) 483-5417 589-2574 Property Location (s): 91 Kokanee Drive Kelly Ridge Estates - Unit 3 - Lot 30 A. P. No. (s): 69-20-04 Fees due: All fees paid. Application for service approved: LAKE OROVILLE AREA PUBLIC UTILITY DISTRICT Inspection(s) made and successful test(s) observed: Location: Date: Lake Oroville Area Public Utility District release to close permit: Date: By: RESIDENTIAL PLAN CHECKING GUIDE (S.F.`, DUPLEX & MISC..ONLY) OWNER GENERAL Zoning requirements: (sideyards and number Valuation. Plans signed by designer. Proper description of work on application. Existing violations on property. Bldg. Permit # A. P. # - -2-0' Plan Checker L of permitted living units). 8/91 6 Items on data sheet. (W.C., fees, Health, Developer Fees, License law, etc). --I! Recorded notice of violation. PLOT PLAN r.GrAding, mplete parcel size and dimensions. tbacks, sideyards, easements, etc. her buildings or structures. fills, drainage. ood hazard. ecial conditions on creation map, tible, and foundations). U & FAS road -setback. (noise, CDF, fire sprinklers, non -comb - Building or utilities across lot lines (Record form). m.nn PT -AM Complete to scale plan with dimensions. equired windows for light and ventilation (Sec. 1205). Required windows for second exit (Sec. 1204). Skylights (Chapter 34 & Sec. 5207). Human impact glass (Sec. 5406). quired room sizes, ceiling heights (Sec. 1207). G7CIs in baths, garage, kitchen, and exterior outlets (Article 210-8). /Light fixtures, switches, receptacles, and exterior receptacles for main- tenance of mechanical equipment. :-�L­ocations of water heater, heating and cooling equipment, other electrical _,,eTT. gas equipment. 0. age firewall, door size, and closer (Sec. 503(d)(3)). 1 - 3'0" exterior exit door (sec. 3304 (f). fireplace and wood stove location, alcoves, and clearance. Smoke detectors (Sec. 1210). Plumbing fixtures, water closet clearances and shower size. STRUCTURAL DETAILS Standard bracing or engineered design (Table 25V) Unusual shape, size, or split level house requiring lateral design. Clerestory requiring balloon framing and/or engineering. 4 --'--Three story building requiring engineered calculations and plans. --5-.-Foundation plan complete enough to construct building. 0 --_'Floor construction details complete enough to construct building. LY.'"Elevations and wall construction details complete enough to construct building 448!roof construction details complete enough to construct building. -:9--Fireplace construction details and talcs if necessary. 4@- Rafter ties or bearing ridge beam. -1T -Garage door or porch header sizes. - Stud heights. -4-3--.-Adobe soils - special foundation design. etaining walls requiring design. Special Inspection required. RESIDENTIAL FLAN•CFECKING GUIDE TO LOOK OUT FOR . Stairway details: landings, rise and run, head clearance, handrails (Sec. 3306). Guardrail details (Sec. 1711 & 3306(j). Brick or stone veneer (Chapter 30). �erior plaster - weep screeds (Sec. 4706). P er roof pitch for roof convering (Chapter 32). Roof covering type - (fire hazard). Foam insulation - protection. 36" halls and stairways. Living area over garage - complete 1 -hour separation required including supporting walls and posts, etc. Two exits on three-story dwellings (sec. 3303 & see Mezannines ttic access and ventilation (Sec. 3205). . Underfloor access and ventilation (Sec. 2516). C 8/91 on garage side - 1716). ombus "on air for fuel burning appliances - L.P.G. requirements. bise requirements on duplexes. _445 --Energy design. lashing at all exterior openings. CDF responsible area requirements. n -- ' CALCULATIONS FOR '' CONCRETE MASONRY CANTILEVER RETAINING WALL ON LAVA CAP BETTER BUILDERS CONSTRUCTION 5263 ROYAL OAKS DRIVE OROVILLE, CA 95966 ` CALCULATIONS ARE IN COMPLIANCE WITH THE 1988 EDITION OF THE UBC ^^ 13I6NED - DATE ----------------+��----------.- , F'RANK L. TYUKOS, RCE 32434 -- ING V� ROAD 872-0254 SUBJECT: CMU CANTILEVER RETAINING WALL BY: FLT DATE: 10/90 JOB NO.: 07! PROJECT: BETTER BUILDERS CONSTRUCTION 5263 ROYAL OAKS DRIVE, OROVILLE, CA 95966 FLT ENGINEERING 5790 CLARK ROAD PARADISE, CA SHEET 1 OF 10 DESIGN_CRITERIA� STUD WALL, ROOF AND FLOOR ARE SUPPORTED BY MASONRY CANTILEVER RETAINING WALL FOUNDATIONS. CODE 1988QBC SUPERIMPOSED LOADS: MIN. DL = .010 x (3+8) = .11 k/l MAX. LL = .016 x 22 + .010 x (22-3) + .050 x 11 = 1.09 k/l LOADING PER ABOVE IS CRITICAL FOR BOTH - SEARIN8 (INCLUDES DL+LL) AND SLIDING RESISTANCE (MIN. DL ONLY)' MAX. LL - ROOF LL + ADD'L LIGHT ROOF DL + FLOOR DL+LL CALC'S PROVIDED FOR: A. 101-0" HIGH WALL - SHEETS 2,3,4,5 & 6 B. 81-8" HIGH WALL - SHEETS 7,8 & 9 CONSTRUCTION DETAIL - SHEET 10 MATERIALS: CONCRETE - W!IMHTL UUMMMb. W|Mmu|M - Mc = Moo rnl u zu u*,n, CMU - ULTIMATE COMPRESSIVE STRENGTH - f'm = 1500 PSI, GROUTED SOILD, NO INSPECTION REWIRED. REINFORCING - ASTM A615` GRADE 40, ALLOWABLE SOIL BEARING PRESSURE - 1500 PSF, ALLOWABLE LATERAL DRG. PRESSURE - 200 PSF 0^rc_ a�a/rC T - | c�^o'm'----_-c^rc=-� ��C ;r,4//k//x/xc Ad /A ~ ---- '- PROJECT : BETTER BUILDERS JOB NO. : 0755 DATE : 10/1990 CALCIS BY : FLT SUBJECT: CONC. MASONRY CANTILEVER -RETAINING _WALL _______________________- WALL DESIGN: ------------ ALL CALCULATIONS ARE IN UNITS/LN. FT. GRADE SLOPE RATIU: SOIL EQUIVALENT FLUID PRESSURE (PSF): SURCHARGE (PSF): YIELD STRENGTH OF REINF. - Fy (KGI): ULTIMATE COMPRESSIVE STRENGTH OF CONCRETE (PSI): ULTIMATE COMPRESSIVE STRENGTH OF CMU (PSI): SPECIAL INSPECTION REQUIRED: ALLOW. COMPRESSIVE STRESS OF CMU - Fm (PSI),'- GRAVITY PSI): GRAVITY LOAD - DEAD LOAD (KIP): - LIVE LOAD (KIP): OVERALL HEIGHT OF THE WALL H (FEET),- FEET):OVERALL OVERALLHEIGHT OF THE SOIL - Hr (FEET): THrCKNESS OF WALL - TOP (INCHES): - BOTTOM (INCHES): GROUTED SOLID - WEIGHT OF GROUT (PCF): AVERAGE WEIGHT OF WALL (PSF): TOTAL EARTH PRESSURE i Fw (KIP): MOMENT - Mw (FT -KIP): AREA REINF. (IN^2) 'd'(IN)____SIZE _&----------- SPA _(IN) _________________________� ----------------------------------------- --- #5 9.29 0.268 9.29 . @ 13 9 ' MIN^ VERTICAL REINF. - .12 % (IN^2): MIN` HORIZONTAL REINF. - .08 % (IN^2): DESIGN REINF. - VERTICAL: #51 = . - HORlZm|*0 05 EFFECTIVE RATIO OF REINF. - p: MODULAR RATIO - n: COEFFICIENT - k: ACTUAL RATIO OF DISTANCE COEFFICIENT - 2/kj: ACTUAL COMPRESSIVE STRESS OF CMU - fm (PSI): ACTUAL TENSIONAL STRESS OF REINF. - fs (KSI): cw,~_~— J/7 FLT ENGINEERING 5790 CLARK ROAD PARADISE, CA (916) 872-0254 SHEET Z OF "�57 LEVEL 30 0 40 2000 1500 NQ 250.00 .11 1.09 10 9 7.6 11.6 135 133 1.22 3.65 0.167 0.111 0,0033 40.0 0.400 0.867 5.765 243.62 < 250.0V 11.69 < 20.00 '° ' FLT ENGINEERING PROJECT : BETTER BUILDERS 5790 CLARK ROAD JOB NO. : 0755 PARADISE, CA DATE : 10/1990 (916) 872-0254 CALCIS BY : FLT HEIGHT FROM TOP OF THE WALL - H2 (FEET): 7 HEIGHT FROM TOP OF THE SOIL - Hr2 (FEET): 6 THICKNESS OF WALL - BOTTOM2 (INCHES): 7.6 GROUTED SOLID - WEIGHT OF GROUT (PCF4 135 AVERAGE WEIGHT OF WALL (PSF): 84 TOTAL EARTH PRESSURE - Fw2 (KIP): 0.54 MOMENT @ Hw2 - Mw2 (FT -KIP): 1.08 AREA REINF. (IN^2) 'dl(IN) SIZE & SPA (IN) ---------------------------------------------------- 0.138 _______________________________________________0.138 5.35 #4 @ 17.4 DESIGN REINF. - VERTICAL. 1*4 @ 161 FOOTING DESIGN: ----------------- DENSITY ______________ DENSITY OF SOIL (PCF): 100 DENSITY OF CONCERTE (PCF): 150 OVERTURNING RATIO - MIN: 1.5 - MAX: ' 2.5 ALLOW. SOIL BEARING PRESSURE (PSF): 2500 ALLOW. LATERAL BEARING PRESSURE (PSF): 400 FRICTION COEFFICIENT - Fc: 0.35 FOOTING DEPTH (INCHES): 18 FOOTING WIDTH HEEL (INCHES): 18 - TOE (INCHES): 30 FOOTING KEY - DEPTH & WIDTH (INCHESA. 0 - BAVK TO BACK OF WALL (INCHES): 0 TOTAL WIDTH OF FOOTING (INCHES): 60 OVERTURNING FORCE - Fo (KIP): OVERTURNING MOMENT - Mo (FT -KIP): ' TOTAL RESISTING WEIGHT - W (KIP): RESISTING MOMENT - Mr (FT -KIP): OVERTURNING RATIO - SF NET MOMENT - Mn (FT -KIP): ECCENTRICITY - e (FEET): ECCENTRIC MOMENT - Me (FT -KIP): FOOTING AREA - Af (FT^2): SECTION MODULUS - S (FT^3): SOIL PRESSURES - DL ONLY - SPt (PSF): - SPh (PSF): SOIL PRESSURES - ADDED LL - SPt' (PSF): - SPh' (PSF): SLIDING RESISTING FORCE - Fr (KIP): 1,65 5.79 4.53 2.59 9.20 0.47 2.13 5.00 4,17 1418.32 < 2500 395.34 > 0 1509.88 < 2500 739.78 > 0 PROJECT : BETTER BUILDERS JOB NO. : 0755 DATE : 10/1990 CALCIS BY : FLT FOOTING - TOE: EARTH PRESSURE @ TOE - Fv (KIP): 3.49 MAX. MOMENT @ TOE - Mt (FT -KIP): 4.52 AREA REINF. (IN^2) 'dl(IN) SIZE & SPA (IN) --------------------------------------------------- 0. 210 --------------------------------------------------0.210 14.69 #5 @ 17.7 DESIGN TOE R FOOTING - HEEL: UNIFORM LOAD @ HEEL - Wv (PLF): 362.46 PRESS. @ TIP DUE TO GRADE SLOPE - SPg (PSF): 0.00 PRESS. @ FACE OF WALL - SPf {PSF): 176.19 MAX. MOMENT @ HEEL - Mh (FT -KIP): 0.33 AREA REINF. (IN^2) 'dl(IN) -------------- 0 SIZE & SPA (IN) ----------------------------------- ----------------------------------0.014 15.69 0. 0 1 1- #5 @ 262.1 1 FLT ENGINEERING 5790 CLARK ROAD PARADISE, CA (916) 872-0254 SHEET f OF la PROJECT : BETTER BUILDERS JOB NO. : 0755 DATE : 10/1990 CALCIS BY : FLT SUBJECT: CONC. MASONRY CANTILEVER RETAINING WALL ----------------- & ------------------------ WALL DESIGN: ------------ ALL CALCULATIONS ARE IN UNITS/LN. FT. GRADE SLOPE RAT SOIL EQUIVALENT FLUID PRESSURE (PSF): SURCHARGE (PSF): YIELD STRENGTH OF REINF. - Fy (KSI): ULTIMATE COMPRESSIVE STRENGTH OF CONCRETE (PSI): ULTIMATE COMPRESSIVE STRENGTH OF CMU (PSI): SPECIAL INSPECTION REQUIRED: ALLOW. COMPRESSIVE STRESS OF CMU - Fm (PSI): GRAVITY LOAD - DEAD LOAD (KIP): - LIVE LOAD (KIP): OVERALL HEIGHT OF THE WALL - H (FEET): OVERALL HEIGHT OF THE SOIL - H. (FEET): THICKNESS OF WALL - TOP (INCHES): - BOTTOM (INCHES): GROUTED SOLID - WEIGHT OF GROUT (PCF): AVERAGE WEIGHT OF WALL (PSF): TOTAL EARTH PRESSURE - Fw (KIP): MOMENT - Mw (FT -KIP): AREA REINF. (IN^2) 'dl(IN) SIZE & SPA (IN) -------------------------------------------------- 0.266 _________-_____________________________________0.268 9.29 #5 @ 13.9 MIN. VERTICAL REINF. - .12 % (IN^2): MIN. HORIZONTAL REINF. - .08 % (IN^2): DESIGN REINF. - - nuR^Zum/*Lz #o @ 32 EFFECTIVE RATIO OF REINF, - p: MODULAR RATIO - n: COEFFICIENT - k: ACTUAL RATIO OF DISTANCE COEFFICIENT - 2/kj: ACTUAL COMPRESSIVE STRESS OF CMU - fm (PSI): ACTUAL TENSIONAL STRESS OF REINF. - fs (KSI): FLT ENGINEERING 5790 CLARK ROAD PARADISE, CA (916) 872-0254 SHEET OF 'Alo LEVEL 30 0 40 2000 1500 NO 250.00 1.22 3.65 0.167 0.111 � / �T' ce^j//-I _r) z'> '�7D' ' 0.0033 40.0 0.400 0.867 5.765 243.62 < 250.00 11.69 < 20.00 PROJECT : BETTER BUILDERS JOB NO. : 0755 DATE : 10/1990 CALCIS BY : FLT FLT ENGINEERING 5790 CLARK ROAD PARADISE, CA (916) 872-0254 SHEET 6; OF 142 HEIGHT FROM TOP OF THE WALL - H2 (FEET): 11 HEIGHT FROM TOP OF THE SOIL - Hr2 (FEET): 6 THICKNESS OF WALL - BOTTOM2 (INCHES): (INCHES): 7.6 GROUTED SOLID - WEIGHT OF GROUT (PCF): WIDTH (INCHESY: 135 AVERAGE WEIGHT OF WALL (PSF): BACK OF WALL (INCHES): 84 TOTAL EARTH PRESSURE - Fw2 (KIP): 60 0.54 MOMENT @ Hw2 - Mw2 (FT -KIP): 1.08 AREA REINF. (IN^2) 'd'(IN) ________________________________________________ SIZE & SPA (IN) 0.138 5.35 #4 @ 17.,l- 7.4DESIGN DESIGNREINF. - VERTICAL: #4 0 16 FOOTING DESIGN: ---------------- ______________DENSITY DENSITYOF SOIL (PCF): 100 DENSITY OF CONCERTE (PCF): 150 OVERTURNING RATIO - MIN: 1.5 - MAX: . 2.5 ALLOW. SOIL BEARING PRESSURE (PSF): 2500 ALLOW. LATERAL BEARING PRESSURE (PSF): 400 FRICTION COEFFICIENT - Fc: 0.35 FOOTING DEPTH (INCHES): 18 FOOTING WIDTH - HEEL (INCHES): l8 - TOE (INCHES): 30 FOOTING KEY - DEPTH-& WIDTH (INCHESY: 0 - BAVK TO BACK OF WALL (INCHES): 0 TOTAL WIDTH OF FOOTING (INCHES): 60 OVERTURNING FORCE - Fo (KIP): OVERTURNING MOMENT - Mo (FT -KIP): TOTAL RESISTING WEIGHT - W (KIP): RESISTING MOMENT - Mr (FT -KIP): OVERTURNING RATIO - SF NET MOMENT - Mn (FT -KIP): ECCENTRICITY - e (FEET): ECCENTRIC MOMENT - Me (FT -KIP): FOOTING AREA - Af (FT^2): SECTION MODULUS - S (FT^3): SOIL PRESSURES - DL ONLY - SPt (PSF): - SPh (PSF): SOIL PRESSURES - ADDED LL - SPt' (PSF): - SPh' (PSF): i.65 5.79 5.13 17.52 3.03 11.73 0.21 ��� 4.17 1291.12 < 2500 762.54 > 0 1382.68 < 2500 1106.98 SLIDING RESISTING FORCE - Fr (KIP): 2.70 > 1.65 PROJECT : BETTER BUILDERS JOB NO. : 0755 DATE : 10/1990 CALCIS BY : FLT SUBJECT: CONC. MASONRY CANTILEVER RETAINING WALL --------------------------------------- WALL DESIGN: -------------- ALL ___________ ALL CALCULATIONS ARE IN UNITS/LN. FT. GRADE SLOPE RATIO: SOIL EQUIVALENT FLUID PRESSURE (PSF): SURCHARGE (PSF)*: YIELD STRENGTH OF REINF. - Fy (KSI): ULTIMATE COMPRESSIVE STRENGTH OF CONCRETE (PSI): ULTIMATE COMPRESSIVE STRENGTH OF CMU (PSI): SPECIAL INSPECTION REQUIRED:'' ALLOW. COMPRESSIVE STRESS OF CMU - Fm (PSI): GRAVITY LOAD - DEAD LOAD (KIP): - LIVE LOAD (KIP)-.- OVERALL KIP):OVERALL HEIGHT OF THE WALL - H (FEET): OVERALL HEIGHT OF THE SOIL - Hr (FEET): THICKNESS OF WALL - TOP (INCHES): - BOTTOM (INCHES): GROUTED SOLID - WEIGHT OF GROUT (PCF): AVERAGE WEIGHT OF WALL (PSF): TOTAL EARTH PRESSURE - Fw (KIP): MOMENT - Mw (FT -KIP): AREA REINF. (IN^2) 'd,(IN) SIZ' & SPA (IN) --------------------------------------------------- _______________________________________________0.188 0.181.3 9.29 #5 @ 19.B MIN. VERTICAL REINF. - .12 % (IN^2): MIN. HORIZONTAL REINF. - .08 % (IN^2): DESIGN REINF. - VE - HORIZONTAL: EFFECTIVE RATIO OF REINF. - p: MODULAR RATIO - n: COEFFICIENT - k: ACTUAL RATIO OF DISTANCE COEFFICIENT - 2/kj: ACTUAL COMPRESSIVE STRESS OF CMU - fm (PSI): ACTUAL TENSIONAL STRESS OF REINF. - fs (KSI): FLT ENGINEERING 5790 CLARK ROAD PARADISE, CA (916) 872-0254 SHEET 7 0F&10 LEVEL 30 0 40 2000 1500 NO 250.00 0.96 2.56 0.167 0.111 0.0017 40.0 0.305 0.898 7.304 216.77 < 250.00 15.84 < 20.00 . PROJECT : BETTER BUILDERS JOB NO. : 0755 DATE : 10/1990 CALCIS BY : FLT FLT ENGINEERING 5790 CLARK ROAD PARADISE, CA (916) 872-0254 HEIGHT FROM TOP OF THE WALL - H2 (FEET): 6 HEIGHT FROM TOP OF THE SOIL - Hr2 (FEET): 5.33 THICKNESS OF WALL - BOTTOM2 (INCHES): 7.6 GROUTED SOLID - WEIGHT OF GROUT (PCF): 135 AVERAGE,WEIGHT OF WALL (PSF): 84 TOTAL EARTH PRESSURE - Fw2 (KIP): 0.43 MOMENT @ Hw2 - Mw2 (FT -KIP): 0.76 AREA REINF. (IN^2) 'dl(IN) SIZE & SPA (IN) --------------------------------------------------- 0.097 _______________________________________________0.097 5.35 #4 @ 24.8 DESIGN REINF. - VERTICAL; #4 16 FOOTING DESIGN: ------------------ DENSITY ______________ DENSITY OF SOIL (PCF): 100 DENSITY OF CONCERTE (PCF): 150 OVERTURNING RATIO - MIN: 1.5 - MAX: 2.5 ALLOW. SOIL BEARING PRESSURE (PSF): 2500 ALLOW. LATERAL BEARING PRESSURE (PSF): 400 FRICTION COEFFICIENT - Fc: 0.35 FOOTING DEPTH (INCHES); 18 FOOTING WIDTH - HEEL (INCHES): 12 - TOE (INCHES): 24 FOOTING KEY - DEPTH & WIDTH (INCHES): 0 - BAVK TO BACK OF WALL (INCHES): 0 TOTAL WIDTH OF FOOTING (INCHES): 48 OVERTURNING FORCE - Fo (KIP): OVERTURNING MOMENT - Mo (FT -KIP): TOTAL RESISTING WEIGHT - W (KIP): RESISTING MOMENT - Mr (FT -KIP): OVERTURNING RATIO - SF NET MOMENT - Mn (FT -KIP): ECCENTRICITY - e (FEET): ECCENTRIC MOMENT - Me (FT -KIP): FOOTING AREA - Af (FT^2): SECTION MODULUS - S (FT^3). SOIL PRESSURES - DL ONLY - SPt (PSF): - SPh (PSF): SOIL PRESSURES - ADDED LL - SPt' (PSF): - SPh' (PSF): SLIDING RESISTING FORCE - Fr (KIP): 10 4.73 0.61 2.09 2.67 1636.91 < 2500 68,05 > 0 1711.85 < 2500 538.11 > 0 PROJECT : BETTER BUILDERS JOB NO. : 0755 DATE : 10/1990 CALCIS BY : FLT FOOTING - TOE: EARTH PRESSURE @ TOE - Fv (KIP): MAX. MOMENT @ TOE - Mt (FT -KIP): AREA REINF. (IN^2) 'dl(IN) SIZE & SPA (IN) ------------------------------------------ 0.150 14.69 #5 @ 23.5 DESIGN TOE RE 3.02 3.40 FLT ENGINEERING 5790 CLARK ROAD PARADISE, CA (916) 872-0254 SHEET F OF //'� Br _.....SGT... ... C A T E ./O._.90 SUI.'£C'•�-f-�!••/ I,./�•.-• tC� /SIT/L C' SHEET NO. /Q.OF.. J05 NC. -� 0 7SS__...._.._ i CONST. 4 4 o Ye & 1 C MU wft G L. 4s SEE �GifNS ---- REQD !/P TO 4=O "1,,Y4X. I "4 C 32 0 , a, h'OiP/Z, '5 /6"c.c. G� CGu/T,. /y2 'KFY /2 L,4V,a --- - 3 SCG Fath' s-04 e X. f 4-#4 e e: CONT. SPF. /�t/F is;® TY,=, C' civ A S *2 T/ES C WA L A . .F% N �,�..• fir.:... /5/OTE e4 -- CONT, CONC, � Q�pf ESSIpNq /ck� N w No.32434 rn Cl q�F �F `A1 �F��� C,��vTIL �Y�,��o ,�fTA l/�//�C/G /DOTES : /, z:)(f 7-0 d.r YL/�,yT p/ F LV 5790 CLARK RD_pMa�H[E[E "l,Ma 9 (916) B72-02 54 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Prdject Title.......... Residence for Mimnaugh Date........ 03/04/92 Project Address........ 91 Kokanee Drive Oroville Documentation Author... Neal Kuopus Company.... .......... CALCTECH Telephone.............. (916) 589-4219 Compliance Method...... MICROPAS3 by Enercomp, Inc. Climate Zone........... 11 Field Check Date MICROPAS3 v3.01 File-MIMNAUCO Weather-CTZ11 Program -FORM CF -1R User#-MP1320 User-CALCTECH Run -Proposed Residence GENERAL INFORMATION Conditioned Floor Area..... Building Type.. .. ..... ... Building FrontOrientation. Number of Dwelling Units... Number of Stories.......... Floor Construction Type.... Infiltration Control....... COUNTY OF BUTTE 2359 sf Single Family DetachecMAR a 1992 Front Facing 45 deg (NE) 1 2 Raised Floor Standard GLAZING Glazing BUILDING SHELL INSULATION Component Insul Exterior Type R -value Location/Comments Wall R-19 FRONT ENTRY, FRONT, RIGHT, TO GARAGE Shading Shading Overhang LEFT, BACK, TO ATTIC Door R-0 FRONT ENTRY, TO GARAGE, RIGHT, BACK S1abEdge R-0 SLAB EDGE F1oorExt R-19 TO OPEN/GARAGE Roof R-38 FLAT CEILING, TILT CEILING GLAZING Glazing Area # of Interior Exterior Framing Orientation (sf) Panes Shading Shading Overhang Type Door Front (NE) 10 2 DRAPES None Yes Wood Window Front (E) 40 2 DRAPES 50% BUG SCREEN None Metal Window Left (S) 96 2 DRAPES 50% BUG SCREEN None Metal Window Front (E) 120 2 DRAPES 50% BUG SCREEN Yes Metal Window Right (N) 88 2 DRAPES 50% BUG SCREEN Yes Metal Window Back (W) 28 2 DRAPES None None Metal Window Back (W) 7 2 DRAPES 50% BUG SCREEN None Metal 1� THERMAL MASS Area Thickness Hard Surfaced/ Type (sf) (in) Exposed Location/Comments S1abOnGrade 131 4.0 Yes LOWER S1abOnGrade 464 4.0 No LOWER InteriorVert 40 4.0 Yes FIREPLACE InteriorHorz 22 4.0 Yes FIREPLACE InteriorHorz 86 1.0 Yes ENTRY CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page,2 CF -1R Project Title.......... Residence for Mimnaugh Date........ 03/04/92 MICROPAS3 v3.01 File-MIMNAUCO Weather-CTZ11 Program -FORM CF -1R User#-MP1320 User-CALCTECH Run -Proposed Residence Assumed System HeatPump Air Conditioner ASSUMED HVAC SYSTEMS Assumed Duct Duct Efficiency Location R -value 8.0 HSPF 0.92 R-5.7 13.60 SEER 0.92 R-5.7 ACTUAL HVAC SYSTEMS Actual Output Manufacturer and Model # Actual System Efficiency (Btuh) (or. approved equal) Heating Cooling Cooling Coil 8.OHSPF 55500 Lennox HP21-651 13.6SEER 58000 Lennox HP21-651 Lennox CB21-651 CEC Maximum Output for Gas Central Furnaces: O/A Btuh WATER HEATING SYSTEMS Tank Capacity Manufacturer and Model # System Type (gal) (or approved equal) Energy Credits Storage, Electric 35.6 STATE 520 TURBO TV-40-KLS None SPECIAL FEATURES/REMARKS R-5.7 duct insulation required R-19 floor insulation required R-19 wall insulation required per Form 3s R-38 insulation required in ceilings per Form 3 Dual pane glazing with metal frames required per elevations HP1: Lennox HP21-651 at 8.OHSPF & 55500Btu/hr. AC1: Lennox HP21-651 with CB21-651 fan/coil AC1: 13.6SEER at 58000Btu/hr. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title.......... Residence for Mimnaugh Date........ 03/04/92 MICROPAS3 v3.01 File-MIMNAUCO Weather-CTZ11 Program -FORM CF -1R User#-MP1320 User-CALCTECH Run -Proposed Residence COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Chapter 2-53 and Title 20, Chapter 2, Subchapter 4, Article 1 of the California Administrative code. This certificate has been signed by the individual with overall design responsibility and the building owner, who shall retain a copy of it and transmit the certificate to any subsequent purchaser of the building. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, all building conservation features which vary are indicated in the Special Features/Remarks section. DESIGNER Name.... John Starr Company. Better Builders Address. 5263 Royal Oaks Dr. Oroville CA 95966 Phone... (916) 589-2574 License. 323225 Signed (date) DOCUMENTATION AUTHOR Name.... Neal Kuopus Company. CALCTECH Address. Drawer G Feather Falls, Phone... (916) 589-4219 OWNER Name.... John & Helen Mimnaugh Company. Address. Phone... Signed (date) ENFORCEMENT AGENCY Name.... Title... Agency.. CA 95940 Phone... Signed QLt f`�C(.�_?_�_�,(/L_ _ 3/4 '9' Signed (date) (date) COMPUTER METHOD SUMMARY Page 1 C -2R Project Title.......... Residence for Mimnaugh Date........ 03/04/92 Project Address........ 91 Kokanee Drive Oroville Documentation Author... Neal Kuopus Company ................. CALCTECH Telephone .............. (916) 589-4219 Compliance Method...... MICROPAS3 by Enercomp, Inc. Climate Zone........... 11 Field Check Date MICROPAS3 v3.01 File-MIMNAUCO Weather-CTZ11 Program -FORM C -2R User#-MP1320 User-CALCTECH Run -Proposed Residence MICROPAS3 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 32.63 19.90 12.73 Space Cooling.......... 17.79 14.07 3.72 Water Heating.......... 8.65 16.06 -7.41 Total 59.07 50.03 9.04 *** Building complies *** GENERAL INFORMATION Conditioned Floor Area..... 2359 sf Building Type .............. Single Family Detached Building Front Orientation. Front Facing 45 deg (NE) Number of Dwelling Units... 1 Number of Building Stories. 2 Weather Data Type.......... ReducedYear Floor Construction Type.... Raised Floor Number of Building Zones... 1 Conditioned Volume......... 20545 cf Footprint Area............. 1795 sf Slab -On -Grade Area......... 594 sf Glazing Percentage......... 19.2 % of FA Average Ceiling Height..... 8.7 ft BUILDING ZONE INFORMATION Floor Vent Special Cond- Area Volume # of Thermostat Height Vent Area Zone Type itioned (sf) (cf) Units Type (ft) (sf) HOUSE Residence Yes 2359 20545 1.00 Setback 8.0 n/a COMPUTER METHOD SUMMARY Page 2 C -2R Project Title.......... Residence for Mimnaugh Date........ 03/04/92 MICROPAS3 v3.01 File-MIMNAUCO Weather-CTZ11 Program -FORM C -2R User#-MP1320 User-CALCTECH Run -Proposed Residence OPAQUE SURFACES Area U- Insul Act Solar Location/ Form 3 Surface (sf) value R-val Azmth Tilt Gains Comments Reference HOUSE 1 Wall 16 0.063 R-19 45 90 Yes FRONT ENTRY 2 Door 10 0.330 R-0 45 90 Yes FRONT ENTRY 3 Wall 137 0.063 R-19 90 90 Yes FRONT 4 Wall 55 0.063 R-19 315 90 Yes RIGHT 5 Wall 114 0.064 R-19 360 90 No TO GARAGE 6 Door 18 0.330 R-0 360 90 No TO GARAGE 7 Wall 202 0.064 R-19 270 90 No TO GARAGE 8 Wall 180 0.062 R-19 180 90 Yes LEFT 13 Wall 370 0.063 R-19 90 90 Yes FRONT 14 Wall 244 0.062 R-19 360 90 Yes RIGHT 15 Door 20 0.330 R-0 360_ 90 Yes RIGHT 16 Wall 282 0.062 R-19 270 90 Yes BACK 17 Door 20 0.330 R-0 270 90 Yes BACK 18 Wall 296 0.062 R-19 180 90 Yes LEFT 19 F1oorExt 1201 0.049 R-19 0 0 No TO OPEN/GARAGE 20 Wall 88 0.066 R-19 45 90 No TO ATTIC 21 Roof 1141 0.025 R-38 0 0 Yes FLAT CEILING 22 Roof 335 0.025 R-38 180 13 Yes TILT CEILING 23 Roof 289 0.025 R-38 360 13 Yes TILT CEILING 0.77 DRAPES 0.66 10 PERIMETER LOSSES 2 Metal Fixed 0.65 Length F2 Insul DRAPES 0.66 11 Window Surface (ft) Factor R-val Location/Comments 270 90 HOUSE DRAPES 0.66 12 Window 56 2 Metal 9 S1abEdge 51 0.720 R-0 SLAB EDGE DRAPES 0.66 10 S1abEdge 9 0.900 R-0 SLAB EDGE 11 S1abEdge 31 0.500 R-0 SLAB EDGE 12 S1abEdge 12 0.550 R-0 SLAB EDGE GLAZING SURFACES z SC Interior SC Area # of Frame Open U- Act Glass Shade Gls+ Surface (sf) Panes Type Type value Azmth Tilt Only Type Shade HOUSE 1 Door 10 2 Wood Hinged 0.65 45 90 0.67 DRAPES 0.57 2 Window 40 2 Metal Slider 0.65 90 90 0.77 DRAPES 0.66 3 Window 40 2 Metal Slider 0.65 180 90 0.77 DRAPES 0.66 4 Window 40 2 Metal Slider 0.65 90 90 0.77 DRAPES 0.66 5 Window 60 2 Metal Slider 0.65 90 90 0.77 DRAPES 0.66 6 Window 20 2 Metal Slider 0.65 90 90 0.77 DRAPES 0.66 7 Window 30 2 Metal Slider 0.65 360 90 0.77 DRAPES 0.66 8 Window 18 2 Metal Slider 0.65 360 90 0.77 DRAPES 0.66 9 Window 40 2 Metal Slider 0.65 360 90 0.77 DRAPES 0.66 10 Window 28 2 Metal Fixed 0.65 270 90 0.77 DRAPES 0.66 11 Window 70 2 Metal Slider 0.65 270 90 0.77 DRAPES 0.66 12 Window 56 2 Metal Slider 0.65 180 90 0.77 DRAPES 0.66 COMPUTER METHOD SUMMARY Page 3 C -2R Project Title.......... Residence for Mimnaugh Date........ 03/04/92 MICROPAS3 v3.01 File-MIMNAUCO Weather-CTZ11 Program -FORM C -2R User#-MP1320 User-CALCTECH Run -Proposed Residence OVERHANGS Area Window Overhang Overhang Surface (sf) Height Length Height HOUSE 1 Door 10 6.0 8.5 2.5 4 Window 40 5.0 2.0 0.3 5 Window 60 6.7 8.0 2.2 6 Window 20 5.0 8.0 1.2 7 Window 30 5.0 2.0 0.3 8 Window 18 3.0 2.0 0.3 9 Window 40 6.7 2.0 0.3 EXTERIOR SHADING Area Shading SC of Surface (sf) Type Ext Shade HOUSE 2 Window 40 50% BUG SCREEN 0.84 3 Window 40 50% BUG SCREEN 0.84 4 Window 40 50% BUG SCREEN 0.84 5 Window 60 50% BUG SCREEN 0.84 6 Window 20 50% BUG SCREEN 0.84 7 Window 30 50% BUG SCREEN 0.84 8 Window 18 50% BUG SCREEN 0.84 9 Window 40 50% BUG SCREEN 0.84 11 Window 70 50% BUG SCREEN 0.84 12 Window 56 50% BUG SCREEN 0.84 THERMAL MASS Area Thick Heat Conduct- Surface Mass Type (sf) (in) Cap ivity R -value Location/Comments HOUSE 1 S1abOnGrade 131 4.0 28.0 0.98 R-0 LOWER 2 S1abOnGrade 464 4.0 28.0 0.98 R-2 LOWER 3 InteriorVert 40 4.0 21.0 0.59 R-0 FIREPLACE 4 InteriorHorz 22 4.0 21.0 0.59 R-0 FIREPLACE 5 InteriorHorz 86 1.0 24.0 0.67 R-0 ENTRY HVAC SYSTEMS Minimum Duct Duct Duct System Type Efficiency Location R -value Efficiency HOUSE HeatPump 8.0 HSPF 0.92 R-5.7 0.920 Air Conditioner 13.60 SEER 0.92 R-5.7 0.920 COMPUTER METHOD SUMMARY Page 4 C -2R Project Title.......... Residence for�Mimnaugh Date........ 03/04/92 MICROPAS3 v3.01 File-MIMNAUCO Weather-CTZ11 Program -FORM C -2R User#-MP1320 User-CALCTECH Run -Proposed Residence Capa- System # of city Type Heaters (gal) Storage Electric 1 36 WATER HEATING SYSTEMS Effic- Standby Input iency Loss Rating 0.990 RE 0.84% 5 kW SPECIAL FEATURES/REMARKS R-5.7 duct insulation required R-19 floor insulation required R-19 wall insulation required per Form 3s R-38 insulation required in ceilings per Form 3 Dual pane glazing with metal frames required per elevations HP1: Lennox HP21-651 at 8.OHSPF & 55500Btu/hr. AC1: Lennox HP21-651 with CB21-651 fan/coil ACI: 13.6SEER at 58000Btu/hr. Pilot Size (Btuh) Credits n/a NONE HVAC SIZING Page 1 HVAC Project Title.......... Residence for Mimnaugh Date........ 03/04/92 Project Address........ 91 Kokanee Drive Oroville Documentation Author... Neal Kuopus Company ................ CALCTECH Telephone .............. (916) 589-4219 Compliance Method...... MICROPAS3 by Enercomp, Inc. Climate Zone........... 11 Field Check Date MICROPAS3 v3.01 File-MIMNAUCO Weather-CTZ11 Program -HVAC SIZING User#-MP1320 User-CALCTECH Run -Proposed Residence GENERAL INFORMATION Floor Area ................. 2359 sf Volume.... .............. 20545 cf Sizing Location............ OROVILLE RS Latitude... ........ 39.5 degrees Winter Outside Design...... 30 F Winter Inside Design....... 70 F Summer Outside Design...... 104 F Summer Inside Design....... 78 F Summer Range ............... 37 F Shading Used ............... Yes Latent Load Fraction....... 0.40 Description HEATING AND COOLING LOAD SUMMARY Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 12670 6280 Glazing Conduction............... 11752 7639 Glazing Solar .................... n/a 14635 Infiltration ..................... 11686 4798 Internal Gain .................... n/a 2100 Ducts ............................ 3611 3545 Sensible Load .................... 39719 38997 Latent Load ...................... n/a 15599 Total Load' 39719 54596 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. CEC Maximum applicable for gas central furnaces only PROPOSED CONSTRUCTION ASSEMBLY: RESIDENTIAL Form 3R Project Title: Date: Project Address: Location:Oroville RS Documentation Author:Neal Kuopus for CALCTECH Tel.:(916) 589-4219 Building Permit No. Checked By: Date: Enforcement Agency Use Only Assembly Name:ATCRRI9WALL Assembly Type:WALL Assembly Tilt:90 Framing Material:WOOD Framing Spacing:16"o.c. Framing %:15% Framing Size•2X6 List of Construction Components R -Value Cavity Frame Outside Surface Air Film 0.17 0.17 1.Building Paper 0.06 0.06 2.R-19 Insulation 17.80 ---- 3.2x6 Framing ----- 5.45 4.0.5" Gypsum Board 0.45 0.45 5. 6. 7. 8. 9. Inside Surface Air Film 0.68 0.68 Total Unadjusted R -Values: 19.16 6.81 RC Rf Framing Adjustment Calculation: (if applicable) 0.0522 x 0.85 + 0.1468 x 0.15 = 0.0664 Total U -Value 1/0.0664 = 15.06 Total R -Value Sketch of Construction Assembly PROPOSED CONSTRUCTION ASSEMBLY: RESIDENTIAL Form 3R Project Title: Project Address: Documentation Author:Neal Kuopus for CALCTECH Date: Location:Oroville RS Tel.:(916) 589-4219 Building Permit No. Checked By: Date: Enforcement Agency Use Only Assembly Name:GARRI9WALL Assembly Type:WALL Assembly Tilt:90 Framing Material:WOOD Framing Spacing:16"o.c. Framing %:15% Framing Size:2X6 List of Construction Components Outside Surface Air Film 1.0.625" Gypsum Board 2.Building Paper 3.R-19 Insulation 4.2x6 Framing 5.0.5" Gypsum Board 6. 7. 8. 9. Inside Surface Air Film Total Unadjusted R -Values: Sketch of Construction Assembly R -Value Cavity Frame 0.17 0.17 0.56 0.56 0.06 0.06 17.80 ----- ----- 5.45 0.45 0.68 19.72 Rc 0.45 0.68 7.37 Rf Framing Adjustment Calculation: (if applicable) 0.0507 x 0.85 + 0.1357 x 0.15 = 0.0635 Total U -Value 1/0.0635 = 15.75 Total R -Value PROPOSED CONSTRUCTION ASSEMBLY: RESIDENTIAL Form 3R Project Title: Project Address: Documentation Author:Neal Kuopus for CALCTECH Date: Location:Oroville RS Tel.:(916) 589-4219 Building Permit No. Checked By: Date: Enforcement Agency Use Only Assembly Name:MASRI9WALL Assembly Type:WALL Assembly Tilt:90 Framing Material:WOOD Framing Spacing:16"o.c. Framing %:15% Framing Size•2X6 List of Construction Components Outside Surface Air Film 1.Hardboard Siding 2.Building Paper 3.R-19 Insulation 4.2x6 Framing 5.0.5" Gypsum Board 6. 7. 8. 9. Inside Surface Air Film Total Unadjusted R -Values: Sketch of Construction Assembly R -Value Cavity Frame 0.17 0.17 0.67 0.67 0.06 0.06 17.80 ----- ----- 5.45 0.45 0.68 19.83 RC 0.45 0.68 7.48 Rf Framing Adjustment Calculation: (if applicable) 0.0504 x 0.85 + 0.1337 x 0.15 = 0.0629 Total U -Value 1/0.0629 = 15.90 Total R -Value PROPOSED CONSTRUCTION ASSEMBLY: RESIDENTIAL Form 3R Project Title: Date: Project Address: Location:Oroville RS Documentation Author:Neal Kuopus for CALCTECH Tel.:(916) 589-4219 Building Permit No. Checked By: Date: Enforcement Agency Use Only Assembly Name:DFR19WALL Assembly Type:WALL Assembly Tilt:90 Framing Material:WOOD Framing Spacing:16"o.c. Framing %:15% Framing Size•2X6 List of Construction Components R -Value Cavity Frame Outside Surface Air Film 0.17 0.17 1.0.625" Plywood 0.77 0.77 2.Building Paper 0.06 0.06 3.R-19 Insulation 17.80 ----- 4.2x6 Framing ----- 5.45 5.0.5" Gypsum Board 0.45 0.45 6. 7. 8. 9. Inside Surface Air Film 0.68 0.68 Total Unadjusted R -Values: 19.93 7.58 RC Rf Framing Adjustment Calculation: (if applicable) 0.0502 x 0.85 + 0.1319 x 0.15 = 0.0624 Total U -Value 1/0.0624 = 16.03 Total R -Value Sketch of Construction Assembly PROPOSED CONSTRUCTION ASSEMBLY: RESIDENTIAL Form 3R Project Title: Project Address: Documentation Author:Neal Kuopus for CALCTECH Date: Location:Oroville RS Tel.:(916) 589-4219 Building Permit No. Checked By: Date: Enforcement Agency Use Only Assembly Name:CSR38CC2412 Assembly Type:ROOF Assembly Tilt:0-22 Framing Material:WOOD Framing Spacing:24"o.c. Framing %: 7% Framing Size:2x6 List of Construction Components Outside Surface Air Film 1.Asphalt Shingles 2.Building Paper 3.0.5" Plywood 4.3.5"+ Air Space 5.R-19 Insulation 6.R-19 Insulation 7.2x6 Framing 8.0.5" Gypsum Board 9. Inside Surface Air Film Total Unadjusted R -Values: Sketch of Construction Assembly R -Value Cavity Frame 0.17 0.17 0.44 0.44 0.06 0.06 0.62 0.62 0.80 0.80 19.00 19.00 19.00 ----- ----- 5.45 0.45 0.45 0.61 41.15 R C 0.61 27.60 Rf Framing Adjustment Calculation: (if applicable) 0.0243 x 0.93 +.0.0362 x 0.07 = 0.0251 Total U -Value 1/0.0251 = 39.84 Total R -Value