Loading...
HomeMy WebLinkAboutFAI15-0079 Fire Annual Inspection 20171 COG FIRE, Butte County Fire Department California Department of Forestry and Fire Protection Fire Prevention Bureau 176 Nelson Avenue, Oroville, CA 95965 530-538-7888/530-538-2105(fax) Fire Safety Inspection Business Address: "�`6 L. to , t Nw `� Business Name: jtu,�,,; (,( L A.L, i- 2, <<<. ct.{4`4 Owner/Manager: "C)'C(.„K 11. Exit sign(s): required, illumination, photo luminescent t, ,Zr7 Bus: 1 - 6444:c; Other: Other Contact: 0r2:; ; I 6 ,r; Bus: '2 - 644 6b Other: Building Owner: , 15. Wiring: exposed, damaged connectors, etc. V Bus: 16. Address posted and visible from road Other: Address: .3 7� Zc 17 17. Other Afi,'t Tr,: irk . F-20 in ' +Nit 9. Fire drill log checked Yes V'No Li Occ. Class: AN INSPECTION OF YOUR FACILITY REVEALED THE FOLLOWING: DETAILED EXPLANATION AND CORRECTIONS: CORRECTED: 1. Fire extinguishers: required, service due /10. Exit(s): obstructed, inadequate ti, t >` Com- PcCe4 . �,AQ-14T r...LK— 2. Extension cords: Excessive use, defective / 11. Exit sign(s): required, illumination, photo luminescent 3. Excessive rubbish, trash, debris 112. Exit sign lights: obstructed, defective 4. Fire alarm system defective 13. Exit lighting: required, defective 5. Sprinkler system: service required, defective 14. Heating system: defective appliance, flue combustibles fr Kitchen hood ext. system: service due , 15. Wiring: exposed, damaged connectors, etc. V 7. Fire walls, ceilings, fire doors, draft stops 16. Address posted and visible from road 8. Smoke detectors: required, defective .3 7� Zc 17 17. Other Afi,'t Tr,: irk . F-20 in ' +Nit 9. Fire drill log checked Yes V'No Li 18. Other type of inspection - State below DETAILED EXPLANATION AND CORRECTIONS: CORRECTED: Z 4 L t 1 . Willful failure to comply with this notice is a misdemeanor. Violations that are not corrected immediately andtor remain after the re -inspection may be processed as a criminal offense. Thank you for your assistance and cooperation in minimizing the fire and life loss in our community. (H & S sec. 13112) required to do so. A re -inspection will be conducted on White Copy — Station File Yellow Copy — Re-inspect/business Pink Copy — Business 111 Check when sent to prevention ti, t >` Com- PcCe4 . �,AQ-14T r...LK— *-17// 7 .3 7� Zc 17 Afi,'t Tr,: irk . F-20 in ' +Nit 5,i.iC. , rric..i-r -- 1 /ZSl 2Ui7 i (:)(-C1 Tc.:COQ.-2/0C /_' Co -1.2-#.:: C.�l - 2 0 Date:Discussed `..-f 2-`-_ I t 1 with: (Print) krc a Signed: • ittalion 1 2 3 4 5 7 Station: U.L't FPB Inspectin. • icer: 01 -4 -Ab Pc -{Z.:7 L -Q 1Sv order of the Fire Chief: You are hereby notified to correct all violations immediately or show cause why you should not he Z 4 L t 1 . Willful failure to comply with this notice is a misdemeanor. Violations that are not corrected immediately andtor remain after the re -inspection may be processed as a criminal offense. Thank you for your assistance and cooperation in minimizing the fire and life loss in our community. (H & S sec. 13112) required to do so. A re -inspection will be conducted on White Copy — Station File Yellow Copy — Re-inspect/business Pink Copy — Business 111 Check when sent to prevention Evangelical Free Church 3785 Olive Hwy Oroville, CA 95966 Butte County Fire / CALFIRE 176 Nelson Ave Oroville, CA 96965 1/25/2017 On February 25th we conducted a fire and life safety inspection at the church and school. Over all the inspection went well. We found a few items that need to be addressed see items listed below. Sound room • Missing switch cover plate • Open sheet rock to the right of the sound board Gym • South Eastern double doors need to open independently of one another. Currently you need to open the right before the left. Kitchen • Remove the door stop on the door that leads to the gym. This is a fire rated door and automatically closes in order to prevent travel of fire. • Move any stored materials from in front of an electrical panel. You should maintain 36" of clearance in front of all electrical panels. Room # 15 • Remove the extension cord to the overhead projector Room #2 • Fix the opening in the sheet rock around the HVAC ducting. • The east exit door doesn't open freely Library • The exit Tight on the east door needs a new battery Music Room Office • Broken switch cover plate Youth Pastors Office • Missing switch plate cover Room #10 • Extension into a power strip needs to be removed Exit signs in all class rooms CFC Sec.1011.3 &1011.6.3 • Exit signs shall be internally or externally illuminated at all times; signs shall be connected to an emergency power system that provides illumination for not Tess than 90 minutes in case of primary power loss. o Note externally illuminated signs are good for 10 years and should bear a stamp with the date. We would like to re -inspect February 8th 2017 at 2pm. If you have any questions or concerns please feel free to contact .j y station personal at (530) 538-7228. Church epre ntative