FAI15-0083 CALFIRE STORAGE TANK INSPECTION 2014
25-96 INSPECTION, TESTING, AND MAINTENANCE OF WATER-BASED FIRE PROTECTION SYSTEMS Inspection, Testing, and Maintenance of Water Storage Tanks Page 1 of 2 NFPA 25, Chapter 9 as amended�by CCR, Title 19 4' 1 Date of Inspection, Testing, Maintenance: /O f , _, of C x°09 Abbreviation Key: co i?�. I =Inspection /.0 �,�s' Property Information: / Name: 66il l �U�y (.:a4Mv T =Test �Vso M = Maintenance A-0= After Operation MI = Per Manufacturer's Instructions * = During cold weather season ,�/ &J /J / Address: eeayier7rF1f) 7tflPl //t t?15 N/A II City: ©PO I% t ll e 1.1 Item Activity - Frequency Description NFPA 25 Reference Fail N/A Pass 1.1 I Daily/Weekly* Water temperature 9.2.4 1.2 I Daily/Weekly* Heating system 9.2.6.6 1.3 I Monthly* Temperature Alarms 9.2.4.2 9.2.4.3 ,t f/ 4. 1.4 I Monthly/ Quarterly* Condition of water in tank 9.2.1 r 1.5 I Monthly/ Quarterly Water- level 9.2.1 (/ 1.6 IMonthly/ Quarterly Air Pressure 9.2.2 1.7 I Quarterly Control Valves 12.3.2.1 1.4 1.8 I Quarterly Tank - exterior 9.2.5.1 j/ 1.9 I Quarterly Support structure 9.2.5.1 Vt 1.10 I Quarterly Catwalks and ladders 9.2.5.1 IZ 1.11 I Quarterly Surrounding area 9.2.5.2 1.12 I Annually Hoops and grillage 9.2.5.4 V 1.13 I Annually Painted/coated surfaces 9.2.5.5 1.14 I Annually Expansion joints 9.2.5.3 / t/ 1.15 I 5 Years/3 Years Interior 9.2.6 // 1.16 I 5 Years Check valves 12.4.2.1 2.1 TMonthly Temperature Alarms 9.2.4.2 9.2.4.3 2.2 T Monthly* High temperature limit switch 9.3.4 2.3 T Semiannually Water level alarms 9.3.5 2.4 T Annually Control Valve - Position 12.3.3.1 Vi 2.5 T Annually Control Valve — Operation 12.3.3.1 2.6 T Annually Supervisory 12.3.3.5 (/ State Fire Marshal AES 6 March 21, 2006 ANNEX B 25-97 Inspection, Testing, and Maintenance of Water Storage Tanks Page 2 of 2 NFPA 25, Chapter 9 as amended by CCR, Title 19 Date of Inspection, Testing, Maintenance: ‘i'--/61‘' G "(.. Abbreviation Key: I = Inspection T =Test M = Maintenance A -O = After Operation MI = Per Manufacturer's * = During cold weather NFPA 25 Reference Fail CA���o'�,I i p! '�, 1 Property Information: t Name: c21'd(Ai/Wry(;i6J J'j0 -- Instructions season 'M t Address: eaSe../14e• V/1- if 0(M ,Jl /n 5 Years Level indicators City:0r iec11 � _ V Item Activity Frequency Description NFPA 25 Reference Fail N/A Pass 2.7 T 5 Years Level indicators 9.3.1 _ V 2.8 T 5 Years Pressure gauges 9.3.6 jV 2.9 T 5 Years Automatic filling device 9.3.7 3.1 M Semiannually Drain silt 9.4.5 1 3.2 M Annually Control valves 12.3.4 inuation pages) q -'/.. .. 4_ i 3.3 M ---- Water level 9.4.1 viii‹: 3.4 M---- Embankment -supported coated fabric (ESCF) 9.4.6 3.5 M ---- Check valves 12.4.2.2 Item Deficiencies and Comments: Deficiencies and Comments Item number must correspond to the Item number of the Activity listed above: ❑ ❑ PASS FAIL ee Continuation Page(s) (Indicate t e number of co inuation pages) q -'/.. .. 4_ i --/ Signature Date State Fire Marshal AES 6 March 21, 2006 FAI15-0083 068-160-076