HomeMy WebLinkAboutFAI15-0078 Fire Annual Inspection 2017FIRE Butte County Fire Department California Department of Forestry and Fire Protection Fire Prevention Bureau 176 Nelson Avenue, Oroville, CA 95965 530-538-7888/530-538-2105(fax) Fire Safety Inspection Business Address: z ti op, t- v. -LIa Air i Business Name: OP h 2, k t-to'oO. Owner/Manager: R :.,—,F} (`0S�►t Bus: 53.2-- 3t Other: Other Contact: Bus: Other: Building Owner: OQ.0.;�l.L iZ, or. t Fr:a:5 Bus: Other: Address: Occ. Class: e N INSPECTION OF YOUR FACILITY REVEALED THE FOLLOWING: TAILED EXPLANATION AND CORRECTIONS: RRECTED: extinguishers: required, service due /10. Exit(s): obstructed, inadequate AFire . Extension cords: Excessive use, defective V 11. Exit sign(s): required, illumination, photo luminescent 1\, 3. Excessive rubbish, trash, debris IN w L t-srfci) 12. Exit sign lights: obstructed, defective 4. Fire alarm system defective 13. Exit lighting: required, defective 5. Sprinkler system: service required, defective 14. Heating system: defective appliance, flue combustibles 6. Kitchen hood ext. system: service due 15. Wiring: exposed, damaged connectors, etc. 7. Fire walls, ceilings, fire doors, draft stopsA6. Address posted and visible from road 8. Smoke detectors: required, defective 17. Other 9. Fire drill log checked Yes Vlo u 18. Other type of inspection — State below TAILED EXPLANATION AND CORRECTIONS: RRECTED: y order of the Fire Chief: You are hereby notified t c rrect all violaton immediately or show cause why you should not be required to do so. A re -inspection will be conducted on Z c, 17 °`^ 3 2 /7 . Willful failure to comply with this notice is a misdemeanor. Violations that are not corrected immediately 'dn /or remain a the re -inspection may be processed as a criminal offense. Thank you for your assistance and cooperation in minimizing the fire and life loss in our community. (H & S sec. 13112) White Copy — Station File Yellow Copy — Re-inspect/business Pink Copy — Business ❑ Check when sent to prevention 4777, \ 1\, i' IN w L t-srfci) Date: I � 2.-co1 0 Discuss (Print) with: yr y A,." S. d: attalion 1 2 3 4 5) 7 Station: r (04 FPB Ins cting Officer: 0 i1"ilO fi.:rz1. y order of the Fire Chief: You are hereby notified t c rrect all violaton immediately or show cause why you should not be required to do so. A re -inspection will be conducted on Z c, 17 °`^ 3 2 /7 . Willful failure to comply with this notice is a misdemeanor. Violations that are not corrected immediately 'dn /or remain a the re -inspection may be processed as a criminal offense. Thank you for your assistance and cooperation in minimizing the fire and life loss in our community. (H & S sec. 13112) White Copy — Station File Yellow Copy — Re-inspect/business Pink Copy — Business ❑ Check when sent to prevention Ophir School 210 Oakvale Ave Oroville, CA 95966 Attn: Rita Costa Attn: Brian Holmes Butte County /CALFIRE 176 Nelson Ave Oroville, CA 95966 Chad Porter: Captain January 26, 2017 On January 26, 2017 we conducted a Title 19 (Fire & Life Safety Inspection) at the Ophir School and found the following issues in need of repair. Please feel free to contact the station with any question. A Re -inspection is scheduled for February 9th 2017 at 3:00 pm. If this time doesn't fit with your schedule please contact us as we will be happy to work with you. • Kitchen door in between the kitchen and cafeteria is a fire rated door and needs to be self-closing. This was an issue in our last inspection • Exit signs (CFC 1011.3 & 1011.6.3) shall be internally or externally illuminated at all times; signs shall be connected to an emergency power system that provides power for not less than 90 minutes in case of primary power failure. If the sign is externally illuminated it will be stamped with a date good for 10 years. o All class rooms must have an exit sign posted. • The 5th & 6th grade classroom area o Both double doors hang up and don't swing freely. • Room 24 o Remove the extension cord that goes to a power strip o We need to research a different method to secure students. I realize that this class services severely disabled students, but with gate and locking mechanism located at the 6' mark can prevent exit to a safe location and needs to be removed immediately. • Extinguishers need to be marked o Room 17 o Library o Room 24 • All storage rooms need to maintain the following. o 36" of clearance around (electrical panels, water heaters, and appliances) o Any room in use needs to maintain free ingress and egress paths. • The school has 2 different sprinkler systems (Furnace / AC room over in the second grade wing and janitor's room off of the gym/ cafeteria). The school needs to verify and show proof of service or that they have been allowed to become decommissioned systems. I talked to Jim Galloway on our last inspection about the sprinkler system and it was my understanding that he has a letter that is allowing the school district to abandon the current partial sprinkler system. I would like to include a copy of the approval in your file. Please let me know if you have any question or concerns. Chad Porter Captain (530) 538-7228 Wet Pipe California Fire Sprinkler System Inspection, Property Information Code of Regulations Testing, and Maintenance - Title 19 Quarterly and 1 of 3 Annual Report Contractor or Licensed Owner Information ' F �A�(As / Y,J 4z-, es, i -A ,, �( `D li, "CS • P MP Building Name Ophir School Name Voltage Specialists ess Address 5031 Foster Road 210 oakvale Ave City Paradise St. CA Zip 95969 City Oroville License # Phone 530-362-2609 Contact Person fl SFM Job # Jim Galloway Ig CSLB 880862 Misc. = Inspection T = Test M = Maintenance P = Pass F = Fail N/A = Not Applicable Main Drain Diameter Main Drain Initial Static Pressure Test (Annual) Residual Pressure NFPA 25 CA ed. Reference Date _ Riser No. Location Riser Diameter Final Static Pressure p F,N/A 1 MP boiler room 1 1/4 N/A N/A N/A N/A N/A 2 Primary building boiler room 1 1/4 N/A N/A N/A N/A N/A Waterflow Alarm Devices 5.2.5 N/A 1.4 1 Supervisory Devices 5.2.5 N/A 1.5 1 Gauges (Wet Pipe Systems) 5.2.4.1 N/A 1.6 1 n This building has more than 5 risers. See additional AES 2.9 form attached Number of AES 2.9 forms attached j I = Inspection T = Test M = Maintenance P = Pass F = Fail N/A = Not Applicable Item Description NFPA 25 CA ed. Reference Date _ •Date Date Date Date_ _�_ 1.1 1 Control Valves - Identification Sign 13.3.1 N/A . 2 1 Control Valves - Inspection 13.3.2 P -r.3 I Waterflow Alarm Devices 5.2.5 N/A 1.4 1 Supervisory Devices 5.2.5 N/A 1.5 1 Gauges (Wet Pipe Systems) 5.2.4.1 N/A 1.6 1 Enter Water Supply Pressure Below Riser Check 5.2.4.1 psi psi psi psi 1.7 1 Enter Water Supply Pressure Above Riser Check 5.2.4.1 psi psi psi psi 1.8 1 Pressure Readings Acceptable 5.2.4.1 N/A 1 9 1 Hydraulic Design Information Sign (for hydraulically designed systems) 5.2.6 N/A 1.10 I General Information Sign (not required for system prior to 2007 edition of NFPA 13) 5.2.8 N/A 1.11 1 Heat Tape 5.2.7 N/A 1.12 I Spare Sprinklers 5.2.1.4 P 1.13 1 Fire Department Connections 13.7 N/A 1.14 1 Alarm Valves - Exterior Inspection 13.4.1 N/A 1.15 1 Pressure Reducing Valves 13.5.1.1 N/A 1.16 1 Backflow Preventers 13.6.1 N/A 1.17 1 Small Hose Connections - Hose Valve 5.1.6, 13.5.2 13.5.5.1 N/A 9 1 PRV - Fire Sprinkler Systems 13.5.1.1 N/A 'Small hose connections are hose valves and optional hose supplied by the fire sprinkler system. They do not include Class I, II, or 111 standpipe systems. I Wet Pipe Fire Sprinkler System California Code of Regulations - Title 19 Inspection, Testing, and Maintenance Quarterly and Annual Report 2 of 3 Property Information Building NameOphir School 'ess 210 oakvale Ave City Oroville Contractor or Licensed Owner Information Name Voltage Specialists Job # ANNUAL INSPECTION, TESTING, AND MAINTENANCE gid,. Include ALL Quarterly Inspections 1 = Inspection T = Test M = Maintenance P = Pass F = Fail N/A = Not Applicable Item Description NFPA 25 CA ed. Reference Date Comments Only P,F,N/A 1.19 I Sprinklers 5.2.1 3/2/17 2.3 P 1.20 1 Buildings (Freeze Protection) 4.1.1.1 3/2/17 Owner's Responsibility P 1.21 I Pipe and Fittings 5.2.2 3/2/17 1,2 P 1.22 I Hangers 5.2.3 3/2/17 P 1.23 I Seismic Braces 5.2.3 N/A 2.1 T Field Service Test Required (Send Report to Fire Code Official) 5.3.1 If REQUIRED, Enter 'F until results are returned from Lab N/A 2 2 T Recalled Sprinklers If not present = Pass; If present = Fail Title 19 904.1(c) N/A 2.3 T Water Flow Alarm Devices 90 sec. maximum - (Enter Time) 5.3.3 13.2.6 sec. N/A 2.4 T Main Drain Test (Enter data on Page 1 of this form) 13.2.5 13.3.3.4 N/A 2.5 T Control Valve - Position 13.3.3.2 3/2/17 P ^ 6 T Control Valve – Operation 13.3.3.1 3/2/17 P z.7 T Supervisory Devices 13.3.3.5 N/A 2.8 T Backflow Preventer Assemblies 13.6.2 N/A 2.9 T Small Hose Connections* w/PRV Hose Valves – Partial Flow Test 13.5.2.3 13.5.3.3 N/A 2.10 T PRV – Fire Sprinkler Systems 13.5.1.3 N/A 3.1 M Control Valves 13.3.4 N/A 3.2 M Small Hose Connections* 13.5.6.3 N/A 3.3 M Obstruction Investigation required (If "Yes", see Deficiencies and Comments Section for Results.) 14.3 _— ,/ Yes No 3.4 M System Returned to Service 4.5.3 Yes No * Small standpipe hose connections are hose valves and optional hose supplied by the fire sprinkler system. They do not include Class I, II, or III systems. D = Deficiency C = Comment Indicate pe) e 6,en tesand om trients laceci 3/2/17 1,2 ✓ Fire systems do not meet NFPA 13 requirements. 2.3 3/2/17 1,2 No water flow switch installed 2.4 3/2/17 1,2 No main drain installed 3 3/2/17 1,2 No inspectors test valve installed 3/2/17 1 Covers only boiler room and old storage room 3 sprinkler heads on system Wet Pipe Fire Sprinkler System California Code of Regulations - Title 19 Quarterly and Inspection, Testing, and Maintenance Annual Report 3 of 3 Property Information Building Name Ophir School ess 210 oakvale Ave City Oroville Contractor or Licensed Owner Information Name Voltage Specialists Job # D = Deficiency Item C Date = Comment Riser (Indicate pe) D G Deficiencies and Comments (cont.) „ .,, irate all equipment, devices and 3arts that were �,a{rel or replaced 03/02/17 2 Sprinkler system only covers boiler room and two storage rooms. 4 heads installed 03/02/17 1,2 No gauges installed on fire sprinkler systems s.� a.; mi nu 1 an Check here if additional Deficiencies and Comments are listed on Form AES9 Number attached: See Correction Form AES 10 for corrected deficiencies. Number attached: I hereby certify that the fire protection equipment listed above has been fully inspected, tested, and maintained on this date by the company indicated above, in accordance with CCR, Title 19, Sections 901 to 906 and that the equipment is fully operable except as noted in the "Deficiencies and Comments" section of this form. L Check box if Annual Inspection, Testing & Maintenance Items are Completed in the Indicated Quarter Quarter 1st - j7 Annual 2nd - fl Annual Date 03/02/17 Print Name Don Cantrell Signature L Don Cantrell 3rd - f Annual 4th - 0 Annual