HomeMy WebLinkAboutFAI15-0060 CF Alarm Inspection 2018 ALARM AND DETECTION REPORT Page 1 of 8 VOLTAGE' SPECIALIsTs 530-624-4514 C10(C16 License#880862 www.VoltageSpecialists.com Inspection # I18-516 ALARM & DETECTION EQUIPMENT TEST REPORT Type of Inspection:Annual Date: 7/3/18 Customer Thermalito school district Site: Sierra ave school Street: 1050 Sierra ave school Contact: Joyce Dennison City/State: Oroville ca Phone#: 530 538-2961 Fax#: 1. Before Test Notify Proper Authorities: Name Phone# A. Owner or Owner's Rep Joyce Dennison 530-5382961 B. Fire Department Sheriff 530-538-7321 C. Central Station NA D. Central Station Acct# NA 2. Control Panel Status Yes No Note# A. Is the system monitored by Central Station? X On Test Time: Return to Service Time: B. Is the Power Light on? X C. Does the Panel indicate Normal conditions? X D. Are all indicating Lamp Bulbs in Operator order? X E. Does the Trouble Light operate? X F. Does the Silence Switch Operate? X G. Battery A.H.7 Date Batteries Installed: 12/28/12 H. Does the Panel have Non-Operational Zones? x I. Does the Panel have Battery Backup? X J. Do the batteries indicate they are Properly Charged? X Condition of Batteries: Out of date Note#1 Battery Voltage with AC Power: Battery Voltage without AC Power: K. List any trouble conditions on panel before test: Note# Note# 2: None of the fire alarm devices are labeled Comments: Note# Note# 3. FACP Manufacturer: Simplex Model# 4002 System Type: Hard wire Location of Annunciators: NA Location of Primary Power Source:Electrical Panel# B Breaker 26 Comments: Note# Note# FCPS: Manufacturer: Simplex Model# 4009 Panel/Breaker# Location:BELOW FACP B/26 Battery Voltage with A/C Power: w/o A/C Power Date: No date FCPS: Manufacturer: Model# Panel/Breaker# Location: Battery Voltage with A/C Power: w/o A/C Power Date: FCPS: Manufacturer: Model# Panel/Breaker# Location: Battery Voltage with A/C Power: w/o NC Power Date: Owner/Rep: Signed copy at district office Phone#: Date: Inspector: Matthew Rennard Phone#: 530-933-8357 Date:7/3/18 /� in 14 n �Iw /i ALARM AND DETECTION REPORT Page 2 of $ Property Site: Sierra ave school Operational #Tested This Equipment Total# Report Yes N/A Note# 4. Remote Annunciators X 5. Zones 22 22 X 6. Manual Stations(Pull) Hardwire 12 12 X Addressable X 7. Detectors Photoelectric 57 57 X Ionization X Heats/Fixed or R of R 54 54 X Flame X Duct(See#15) X 8. Horn/Strobe 6 6 X Strobe Only 27 27 X Bell Speakers x Horn 27 27 X 9. 10. Automatic Door Release X 11. Water Flow switches X Did W/F Ring Outside Bell? X Did W/F Activate Alarm Panel? X 12. Tamper Switches X 13. PIV X OS &Y X 14. 15. Did test of Duct Detectors shut down air handling units? X 16. Did the Monitoring Center(Fire Dept, Central Station, Lease Line)receive signal? X 17. Is system reset for normal conditions? X 18. Is system restored to operational service? X 19. Have Proper Authorities (see#1)been notified system is back in service? X List Proper Authorities: 20. Indicate%of equipment tested this report 25% 50% 75% V 100% 21. Indicate%of equipment tested YTD 25% 50% 75% V 100% Comments for any"no"answers or explanations(Note#): 7/Q/1 Q J D ALARM AND DETECTION REPORT Page 3 of 8 Property Site: Sierra ave school Zone or DEVICE SLC DEVICEn TYPE DEVICE LOCATION PASS FAIL NOTE it CHANNEL PSD ADMIN NE ROOM X 2 1 PSD ADMIN PRINCIPALS X 2 2 PSD ADMIN FILE ROOM X 2 3 PSD ADMIN MAIN OFFICE X 2 4 PSD ADMIN MAIN OFFICE ALCOVE X 2 5 PSD NURSES OFFICE X 2 6 PSD NURSES ROOM X 2 7 PSD ADMIN COPY ROOM X 2 9 PSD ADMIN BREAK ROOM X 2 10 PSD ADMIN HALL TO RESTROOMS X 2 11 PSD KINDERGARTEN ROOM 2 X 23 1 PSD KINDERGARTEN ROOM 2 X 23 2 PSD KINDERGARTEN ROOM 1 X 23 5 PSD KINDERGARTEN ROOM 1 X 23 6 PSD KINDERGARTEN ROOM 1 X 23 7 PSD ROOM 5 X 15 3 PSD ROOM 5 X 15 4 PSD ROOM 4 X 13 1 PSD ROOM 4 X 13 2 PSD LIBRARY X 13 3 PSD LIBRARY X 13 4 PSD ROOM 10 X 22 1 PSD ROOM 10 X 22 2 PSD ROOM 11 X 22 3 PSD ROOM 11 X 22 4 PSD ROOM 12 X 22 5 PSD ROOM 12 X 22 6 PSD ROOM 13 X 22 7 PSD ROOM 13 X 22 8 PSD ROOM 14 X 21 4 PSD ROOM 14 X 21 5 to r4 0 ///L _, ALARM AND DETECTION REPORT Sierra ave schoolPage 4 of 8 Zone or DEVICE DEVICE sLC TYPE DEVICE LOCATION PASS FAIL NOTE# CHANNEL # PSD ROOM 15 X 21 6 PSD ROOM 15 X 21 7 PSD ROOM 9 X 17 1 PSD ROOM 9 X 17 2 PSD ROOM 8 X 17 3 PSD ROOM 8 X 17 4 PSD ROOM 7 X 19 1 PSD ROOM 7 X 19 2 PSD ROOM 6 X 19 3 PSD ROOM 6 X 19 4 PSD GYM X 8 1 PSD GYM X 8 2 PSD GYM X 8 3 PSD GYM X 8 4 PSD GYM X 8 5 PSD GYM X 8 6 PSD GYM X 8 7 PSD GYM X 8 8 PSD GYM X 8 9 PSD STAGE X 8 10 PSD STAGE X 8 11 PSD STAGE X 8 12 PSD GYM NORTH WEST ROOM X 8 13 PSD GYM SOUTH WEST ROOM X 8 14 PSD KITCHEN SOUTH EXIT X 10 5 PSD KITCHEN RESTROOM X 10 7 ni+o I. ALARM AND DETECTION REPORT Sierra ave school Page 5 of 8 Zone or DEVICE SLC DEVICE TYPE DEVICE LOCATION PASS FAIL NOTE# CHANNEL # HT NURSES RESTROOM X 2 8 HT ADMIN MENS RESTROOM X 2 12 HT ADMIN WOMENS RESTROOM X 2 13 HT ADMIN STORAGE BY MENS RR X 2 14 HT ADMIN STORAGE BY WOMENS RR X 2 15 HT KINDERGARTEN ROOM 2 RESTROOM X 23 3 HT KINDERGARTEN KITCHEN X 23 4 HT KINDERGARTEN ROOM 1 RR X 23 8 HT KINDERGARTEN ROOM 1 STORAGE X 23 9 HT BOYS RESTROOM BY ROOM 5 X 15 1 HT GIRLS RESTROOM BY ROOM 5 X 15 2 HT GIRLS RESTROOM BY ROOM 13 X 21 1 HT BOYS RESTROOM BY ROOM 13 X 21 2 HT CUSTODIAL ROOM BY ROOM 13 X 21 3 HT MAINTANCE SHOP BY ROOM 8 X 17 5 HT BOYS RR BY ROOM 6 X 19 5 HT STAFF RESTROOM BY ROOM 6 X 19 6 HT CUSTODIAL BY ROOM 6 X 19 7 HT GIRLS RR BY ROOM 6 X 19 8 HT GYM STORAGE X 10 1 HT KITCHEN X 10 2 HT KITCHEN X 10 3 HT KITCHEN X 10 4 HT KITCHEN RESTROOM X 10 6 HT KITCHEN CUSTODIAL X 10 8 HT KITCHEN OFFICE X 10 9 HT GYM ELECTRICAL X 10 10 HT GYM AC ROOM X 10 11 HT GYM AC ROOM X 10 12 HT CUSTODIAL BY ROOM 7 ATTIC X _ 18 1 HT CUSTODIAL BY ROOM 7 ATTIC X 18 2 _ HT ROOM 8 ATTIC X 18 3 HT ROOM 8 ATTIC X 18 4 7/11/1Q ,I, o ALARM AND DETECTION REPORT Sierra ave school Page 6 of 8 Zone or DEVICE SLC DEVICE TYPE DEVICE LOCATION PASS FAIL NOTE it CHANNEL # HT ROOM 9 ATTIC X 18 5 HT ROOM 9 ATTIC X 18 6 HT BREEZEWAY BETWEEN 7&8 X 18 7 HT BREEZEWAY BETWEEN 7&8 X 18 8 HT ROOM 7 ATTIC X 20 1 HT A ROOM 7 ATTIC X 20 2 HT ROOM 6 ATTIC X 20 3 HT ROOM 6 ATTIC X 20 4 HT BREEZEWAY BETWEEN 4&5 ATTIC X 14 1 HT BREEZEWAY BETWEEN 4&5 ATTIC X 14 2 HT _ ROOM 4 ATTIC X 14 3 HT ROOM 4 ATTIC X 14 4 HT _ ROOM 3 ATTIC X 14 5 HT ROOM 3 ATTIC X 14 6 HT ROOM 5 ATTIC X 16 1 HT ROOM 5 ATTIC X 16 2 HT ROOMS 14&15 BREEZEWAY X 21 7 HT MAIN OFFICE ATTIC X 3 1 HT MAIN OFFICE ATTIC X 3 2 HT UNDER STAGE X 9 1 HT UNDER STAGE X 9 2 -71n is n 1111_ i ALARM AND DETECTION REPORT Sierra ave school Page 7 of 8 Zone or DEVICE DEVICE SLC # TYPE DEVICE LOCATION PASS FAIL NOTE# CHANNEL PS MAIN OFFICE X 1 1 PS ROOM 20 X 5 1 PS ROOM 24 X 5 2 PS ROOM 25 X 5 3 PS ROOM 19 X 6 1 PS ROOM 18 X 7 1 PS ROOM 17 X 7 2 PS ROOM 16 X 7 3 PS GYM EAST X 4 1 PS GYM NORTH X 4 2 PS GYM SOUTH X 4 3 PS KITCHEN SOUTH EXIT X 4 4 WF STAGE x 12 1 WF BELOW STAGE x 12 2 „o LI I ALARM AND DETECTION REPORT Sierra ave school Page 8 of 8 Zone or DEVICE SLC DEVICE CHANNEL # TYPE DEVICE LOCATION PASS FAIL NOTE# LEGEND PSL—Photoelectric Smoke Detector BD—Beam Detector H—Horn V—Visual ISD—Ionization Smoke Detector PS—Pull Station WPH—Weather Proof Horn TS—Tamper Switch PDD—Photo Duct Smoke Detector RR—Rate of Rise Heat Detector C—Chime WF—Water Flow Switch IDD—Ion Duct Smoke Detector HT—Fixed Temp Heat Detector CV—Chime Visual DH—Door Holder DHS—Door Holder&Smoke Detector FD—Flame Detector S—Speaker OSY—OutsideStem&YokeTamperValve ;SR—Signal station Smoke Detwctor R—Kull AV—Audible Visual PR/—Post in irate Valve Cur-Elevator Curtains FRD-Fire Rolldown Door SDC Smoke Detector&Door Holder Combo CO-Carbon Monoxide Detector - - - NOTE# COMMENT see discrepancy report 7/q/1 R IA 1