SCOPE:
INSTALL PHOTOVOLTAIC SOLAR SYSTEM ON A
GROUND MOUNT, AND UPDATE ELECTRICAL
EQUIPMENT AS NEEDED IN ACCORDANCE WITH
ALL APPLICABLE BUILDING CODES SPECIFICALLY
REFERENCING THE 2016 CALIFORNIA
ELECTRICAL CODE USING THE FOLLOWING
SPECIFIC EQUIPMENT:
PROJECT OWNER:
CONTRACTOR:
PAGE #CONTENT
BUILDING JURISDICTION:
ALTERNATIVE ENERGY SYSTEMS INC.
13620 HIGHWAY 99
CHICO, CA 95973
CSLB: 853351 C-10, C-46
SCOPE
CODE REFERENCE
SITE PLAN
STRINGING & RAIL LAYOUT
SINGLE LINE DIAGRAM
LABEL DIAGRAM
FOOTING DETAILS
MODULE SPECS
INVERTER SPECS
WIRE CALCS
PV-1.0
PV-1.1
PV-2.0
PV-3.0
PV-4.0
PV-4.1
PV-5.0
ATTACHMENT
N N
PARCEL MAP:
DIRECTION MAP:
SHEET
REVISION
1 3 6 2 0 H W Y 9 9
C H I C O , C A 9 5 9 7 3
P H O N E #: (5 3 0 ) 3 4 5 -6 9 8 0
F A X #: (5 3 0 ) 8 9 2 -2 3 6 0
d e s i g n @ s a v i n g e n e r g y f o r l i f e .c o m
PV-1.0
CONSULTANT:
DESIGNER:
J. MIKLES
D. VELAZQUEZ
DATE MODIFIED
SCALE
06/20/2019
H O R N E R , C R A I G
4 9 6 5 L A G O V I S T A W A Y
P A R A D I S E , C A 9 5 9 6 9
A P N :0 5 5 -4 8 0 -0 0 5 P H #: (5 3 0 ) 5 2 0 -0 0 4 1
HORNER, CRAIG
4965 LAGO VISTA WAY
PARADISE, CA 95969
APN:055-480-005 PH#: (530) 520-0041
EMAIL: sunvalley1986@gmail.com
1. (N)MODULES: REC
(56) REC320NP
1007 SQFT COVERED
2.(N) INVERTER(S): ENPHASE: IQ7PLUS-72-2-US
(56) MODULE INTERGRATED 240W [N1]
16.262kW AC SYSTEM
3. (E)BATTERY SYSTEM(S): TESLA
(1) POWERWALL
5.76kW AC SYSTEM
1" = 60'-0"(1:720)
SCOPE
8.FALL ARREST PROTECTION PER OSHA REQUIREMENTS
SHALL BE PROVIDED FOR ALL ROOF WORK.
9.ALL CONDUCTORS AND TERMINATIONS SHALL BE
RATED FOR 75° C MINIMUM.
10.2016 CEC ART. 690.5(C) & 690.35(F) - SEE LABEL
DIAGRAM
11.2016 CEC ART. 690.53. - SEE LABEL DIAGRAM
12.2016 CEC ART. 690.17(E). EACH AC DISCONNECT SHALL
ALSO BE LABELED WITH: “WARNING!-ELECTRICAL
SHOCK HAZARD - DO NOT TOUCH TERMINALS.
TERMINALS ON BOTH LINE AND LOAD SIZE MAY BE
ENERGIZED IN THE OPEN POSITION”.
13.DC DISCONNECT AT THE INVERTER WILL BE READILY
ACCESSIBLE AFTER THE INSTALLATION IS COMPLETE PER
2016 CEC ART. 690.17 WHERE TERMINALS OF THE
DISCONNECTING MEANS MAY BE ENERGIZED IN THE
OPEN POSITION. PROVIDE A WARNING SIGN OF THE
HAZARDS PER 2016 CEC ART.690.17
14.CONTRACTOR TO PROVIDE GROUND FAULT
PROTECTION FOR ROOF MOUNTED PHOTOVOLTAIC
ARRAYS LOCATED ON DWELLINGS PER 2016 CEC
ART.690.35.
15.WHERE MORE THAN ONE NOMINAL VOLTAGE SYSTEM
EXIST, THE DIFFERENT SYSTEMS SHALL BE IDENTIFIED BY
PHASE AND SYSTEM PER 2016 CEC ART.210.5(C)(1)
16.PROVIDE AN ACCESSIBLE DISCONNECT DEVICE THAT IS
LOCKABLE IN OPEN POSITION AND IS LOCATED WITHIN
10'-0” OF THE METER PER LOCAL ELECTRICAL UTILITY
REGULATIONS.
17.PHOTOVOLTAIC SOURCE CURRENTS MUST BE RATED AT
BOTH 125% OF THE PARALLEL MODULE AND AT A
CONTINUOUS LOAD OF ANOTHER 125% FOR A TOTAL
OF 156% OF THE LOAD.
18.PROVIDE PERMANENT PLAQUE OR DIRECTORY
PROVIDING THE LOCATION OF THE SERVICE
DISCONNECTING MEANS AND THE PHOTOVOLTAIC
SYSTEM DISCONNECT MEANS IF THEY ARE NOT IN THE
SAME LOCATION PER 2016 CEC ART.690.56.
19.INSTALLATION OF PV PANEL ARRAYS SHOULD RESIST
SLIDING AND POP-UP RESULTING FROM SEISMIC
EVENTS AND SHOULD COMPLY WITH 2016 CBC SECTION
1613A AND ASCE STANDARD 7-05, CHAPTER 13 13.2.1.
20.PV SYSTEM INSTALLER WILL BE RESPONSIBLE FOR
FURNISHING AND INSTALLATION OF ALL RELATED
EQUIPMENT, CABLES, ADDITIONAL CONDUITS, BOXES
WIREWAYS AND OTHER ACCESSORIES NECESSARY FOR
COMPLETE AND OPERATIONAL PHOTOVOLTAIC
SYSTEMS.
21.PV SYSTEM CONTRACTOR SHALL COORDINATE ALL THE
WORK WITH THE ENGINEER, THE CONSTRUCTION
MANAGER AND ALL OTHER CONTRACTORS TO ENSURE
THAT PV SYSTEM IS INSTALLED AS SPECIFIED IN THESE
DRAWINGS.
22.DRAWING IN GENERAL OR DIAGRAMMATIC AND
INDICATE GENERAL ARRANGEMENT OF THE
EQUIPMENT AND WORK INCLUDED. THE INTENTION OF
THE DRAWING IS TO INDICATE SIZE, CAPACITY,
APPROXIMATE LOCATION AND GENERAL
RELATIONSHIP, BUT NOT EXACT DETAIL OR PHYSICAL
PLACEMENT.
23.FIELD VERIFIES EXACT AIC RATING REQUIRED OF THE
MAIN SWITCHBOARD FROM LOCAL UTILITY.
24.A PV SYSTEM WITH MULTIPLE INVERTERS, WHERE
INVERTERS ARE REMOTELY LOCATED FROM EACH
OTHER, WILL HAVE A DIRECTORY CREATED FOR EACH
LOCATION. AS PER 2016 CEC 690.4(D) AND IN
ACCORDANCE WITH 2016 CEC 705.10.
25. SOLAR INVERTER INSTALLED IS A SMART INVERTER PER
CALIFORNIA RULE 21
1.ALL EQUIPMENT SHALL BE LISTED AND LABELED PER
RECOGNIZED ELECTRICAL TESTING LABORATORY AN
INSTALLED PER THE LISTING REQUIREMENTS AND THE
MANUFACTURER'S INSTRUCTIONS.
2.ALL INVERTERS SHALL BE IEEE 929 COMPLIANT AND SHALL
BE INSPECTED BY LOCAL UTILITY BEFORE
COMMISSIONING, TESTING, AND OPERATION OF THE
SYSTEM.
3.ALL OUTDOOR EQUIPMENT SHALL BE MINIMUM NEMA
3R, INCLUDING OUTDOOR MOUNTED TRANSITION BOXES,
COMBINER BOXES, AND SWITCHES.
4.ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE
REQUIREMENTS OF 2016 CEC ART.250,690.
5.2016 CEC. ART. 690.9(A). ALL CIRCUITS CONNECTED TO
MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT
DEVICES LOCATED SO AS TO PROVIDE OVERCURRENT
PROTECTION FROM ALL SOURCES.
6.2016 CEC ART. 690.18. DUE TO THE FACT THAT PV
MODULES ARE ENERGIZED WHENEVER THEY ARE EXPOSED
TO LIGHT, PV CONTRACTOR SHALL DISABLE THE ARRAY
DURING INSTALLATION AND SERVICE BY SHORT
CIRCUITING, OPEN CIRCUITING, OR COVERING THE ARRAY
WITH AN OPAQUE COVERING.
7.PHOTOVOLTAIC SYSTEM SHALL BACKFEED THE
DISTRIBUTION SYSTEM ON SITE PER THE REQUIREMENTS
OF 2016 CEC ART.690.64(B). ALL BACKFEED BREAKERS
SHALL BE IDENTIFIED AS SUCH AND SHALL BE SECURED IN
PLACE BY ADDITIONAL FASTENER PER THE REQUIREMENTS
OF 2016 CEC 408.16(F) (408.36 IN CEC.
ALL WORK SHALL BE IN ACCORDANCE WITH:
2016 CALIFORNIA RESIDENTIAL CODE (CRC)
2016 CALIFORNIA BUILDING CODE (CBC)
2016 CALIFORNIA FIRE CODE (CFC)
2016 CALIFORNIA ELECTRICAL CODE (CEC)
2016 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBSC)
SHEET
REVISION
1 3 6 2 0 H W Y 9 9
C H I C O , C A 9 5 9 7 3
P H O N E #: (5 3 0 ) 3 4 5 -6 9 8 0
F A X #: (5 3 0 ) 8 9 2 -2 3 6 0
d e s i g n @ s a v i n g e n e r g y f o r l i f e .c o m
PV-1.1
CONSULTANT:
DESIGNER:
J. MIKLES
D. VELAZQUEZ
DATE MODIFIED
SCALE
06/20/2019
H O R N E R , C R A I G
4 9 6 5 L A G O V I S T A W A Y
P A R A D I S E , C A 9 5 9 6 9
A P N :0 5 5 -4 8 0 -0 0 5 P H #: (5 3 0 ) 5 2 0 -0 0 4 1
NTS
CODE
REFERENCE
20'-0"
32'-0"
186'-2"
151'-4"
53'-2"
96' TO PROPERTY LINE
SHEET
REVISION
1 3 6 2 0 H W Y 9 9
C H I C O , C A 9 5 9 7 3
P H O N E #: (5 3 0 ) 3 4 5 -6 9 8 0
F A X #: (5 3 0 ) 8 9 2 -2 3 6 0
d e s i g n @ s a v i n g e n e r g y f o r l i f e .c o m
PV-2.0
CONSULTANT:
DESIGNER:
J. MIKLES
D. VELAZQUEZ
DATE MODIFIED
SCALE
06/20/2019
H O R N E R , C R A I G
4 9 6 5 L A G O V I S T A W A Y
P A R A D I S E , C A 9 5 9 6 9
A P N :0 5 5 -4 8 0 -0 0 5 P H #: (5 3 0 ) 5 2 0 -0 0 4 1
(E) COMPOSTION ROOFW/ WOOD TRUSSESROOF CONDITIONS:(N) AC DISCONNECT
(N) AC GENERATION PANEL &
(N) MONITORING LOCATION
(E) COMPOSTION ROOFW/ WOOD TRUSSES
(E) PROPERTY SETBACKS
(E) JUNCTION BOX
(P) TRENCH 1
SOIL CONDITION: EASY
DISTANCE:30' 0"
(P) TRENCH 2
SOIL CONDITION: EASY
DISTANCE:35' 0"
(E) MAIN SERVICE PANEL &
(E) PG&E METER LOCATION
(R) AC DISTRIBUTION PANEL
(E) TESLA GATEWAY
(2)(N) AC LOAD PANEL
10' VEGETATION FREE AREA
(E) 2" UNDERGROUND CONDUIT
(E) RESIDENCE
(N) LINE OF SIGHT ANTENNA
(N) LINE OF SIGHT ANTENNA
(P) ARRAY 1 LOCATION(28)
(P) ARRAY 2 LOCATION(28)
(E) LEACH LINES
(E) SEPTIC TANK
1" = 20'-0"(1:360)
SCALE: 1" = 20'-0"(1:240)
N
SITE
PLAN
VLDR - 1.75ACRE
PROPERTY SETBACKS:
FRONT YARD: 20'-0"
STREET SIDE: 10'-0"
PARCEL SIDE: 20'-0"
REAR YARD: 20'-0"SITE PLAN LEGEND
EXISTING LEACH LINES
EXISTING IRRIGATION
LINE
PARCEL LINE
EXISTING GAS
LINE PROPOSED TRENCH
EXISTING CONDUIT(P) = PROPOSED
(E) = EXISTING
(N) = NEW
(R) = REMOVE
NOTE LEGEND
= 10' BRUSH FREE ZONE
SETBACK LEGEND
= PROPERTY SETBACK
20'10'0'40'
SHEET
REVISION
1 3 6 2 0 H W Y 9 9
C H I C O , C A 9 5 9 7 3
P H O N E #: (5 3 0 ) 3 4 5 -6 9 8 0
F A X #: (5 3 0 ) 8 9 2 -2 3 6 0
d e s i g n @ s a v i n g e n e r g y f o r l i f e .c o m
PV-3.0
CONSULTANT:
DESIGNER:
J. MIKLES
D. VELAZQUEZ
DATE MODIFIED
SCALE
06/20/2019
H O R N E R , C R A I G
4 9 6 5 L A G O V I S T A W A Y
P A R A D I S E , C A 9 5 9 6 9
A P N :0 5 5 -4 8 0 -0 0 5 P H #: (5 3 0 ) 5 2 0 -0 0 4 1
ATTACHMENT DIAGRAMATTACHMENT DIAGRAM
Q CABLE
TERMINATOR
LEGEND
PARALLEL CONNECTION
SEALING CAP
0
'
-
0
"
8
'
-
0
"
1
6
'
-
0
"
2
4
'
-
0
"
3
2
'
-
0
"
0'-0"
8'-9"
0 '-0 "
2 '-8 "
5 '-6 "
8 '-2 "
1 3 '-9 "
1 1 '-1 "
1 6 ''-7 "
1 9 '-3 "
2 2 '-1 "
2 4 '-1 0 "
2 7 '-8 "
3 0 '-4 "
3 3 '-3 "
3 5 '-1 1 "
1 8 0 ° A Z
1
3
°
T
I
L
T
SCALE: 1/8" = 1'
SCALE: 1/4" = 1'
STRINGING DIAGRAM ARRAY 2 SCALE: 1/8" = 1'STRINGING DIAGRAM ARRAY 1
AS NOTED
STRINGING &
RAIL LAYOUT
(N) LINE OF SIGHT ANTENNA
(N) LINE OF SIGHT ANTENNA
(N)EATON BRS225
(E) UNDERGROUND JUNCTION BOX
(N)ARRAY 2
(N)ARRAY 1
(N)POLARIS IPLD 250-3
DUAL ENTRY 3 PORT CONNECTOR
FIELD VERIFIED TORQUE VALUE
(E) HOME SUB PANEL FEEDERS
SPLICE ON FEEDERS
SHEET
REVISION
1 3 6 2 0 H W Y 9 9
C H I C O , C A 9 5 9 7 3
P H O N E #: (5 3 0 ) 3 4 5 -6 9 8 0
F A X #: (5 3 0 ) 8 9 2 -2 3 6 0
d e s i g n @ s a v i n g e n e r g y f o r l i f e .c o m
PV-4.0
CONSULTANT:
DESIGNER:
J. MIKLES
D. VELAZQUEZ
DATE MODIFIED
SCALE
06/20/2019
H O R N E R , C R A I G
4 9 6 5 L A G O V I S T A W A Y
P A R A D I S E , C A 9 5 9 6 9
A P N :0 5 5 -4 8 0 -0 0 5 P H #: (5 3 0 ) 5 2 0 -0 0 4 1
(N)AC-MONITORING 1
(1) 1/2" EMT w/
(3) #14 THWN-2 CU. &
(1) #14 THWN-2 CU. GRD.
WIRE RUN: 10'
(E) #1 CU.
(N) AC-1
(1) 1" PVC w/
(6) #10 THWN-2 CU. &
(1) #10 THWN-2 CU. GRD.
WIRE RUN: 40'
IMAX: 14.52A
(N) AC-2
(1) 1" EMT w/
(6) #10 THWN-2 CU. &
(1) #10 THWN-2 CU. GRD.
WIRE RUN: 10'
IMAX: 14.52A
(N) AC-3
(1) 2" PVC w/
(3) #3/0 XHHW-2 AL. &
(1) #4 XHHW-2 AL. GRD.
WIRE RUN: 35'
IMAX: 67.76A
(E) 1 1/2" EMT w/
(N)AC-4
(3) #1/0 THWN-2 CU. &
(1) #6 THWN-2 CU. GRD.
WIRE RUN: 10'
(E) 1 1/2" EMT w/
(N)AC-4
(3) #1/0 THWN-2 CU. &
(1) #6 THWN-2 CU. GRD.
WIRE RUN: 10'
(N) AC-5
(1) 1 1/2" EMT w/
(3) #3 THWN-2 CU. &
(1) #4 THWN-2 CU. GRD.
WIRE RUN: 10'
(N)ENPHASE
ENVOY
(E) ROUTER
(E) 2" PVC
DISTANCE: 125'
(N) AC-3
(3) #3/0 XHHW-2 AL. &
(1) #4 XHHW-2 AL. GRD.
WIRE RUN: 135'
IMAX: 67.76A
(E) AC (E) AC
(E) AC SERVICE PANEL200A/ 1Ø/ 240VSCIR:XXXXX
NOTES
15A2P 125A
ENH202
TRANSFER
SWITCH
GENERATOR
120V=N-L1-L2=240V
120V=N-L2-L3=NAV
NAV=N-L3-L1=NAV
SERVICE VOLTAGE
METER#1009864388
(E)200A
(E) AC SERVICE PANEL
400A BUS SPLIT/ 1Ø/ 240V
SCIR: 22000
MILBANK WEST: M400-UG-APS-LC
GENERATION PANEL
(N)AC DISTRIBUTION PANEL
125A/ 1Ø/ 240V
CUTLER-HAMMER: BR1224L125R
4
12
12
(N) JUNCTION
BOX
(N) AC- CABLES w/
(3) TRANSITION CABLE(S)
WIRE RUN: 5'
IMAX: 14.52A
(28) PV MODULES/INVERTERS[N1]
REC:REC320NP
ENPHASE:IQ7PLUS-72-2-US
1.21A/1Ø/240V
4
12
12
(N) JUNCTION
BOX
(N) AC- CABLES w/
(3) TRANSITION CABLE(S)
WIRE RUN: 5'
IMAX: 14.52A
(28) PV MODULES/INVERTERS[N1]
REC:REC320NP
ENPHASE:IQ7PLUS-72-2-US
1.21A/1Ø/240V
(N)20A
2P
(E)200A
(N)90A
2P
(E) TESLA POWERWALL
LOCATION: GARAGE
+
-
(N)30A
2P
HOME SUB-PANEL
(E)AC DISTRIBUTION PANEL
125A BUS/ 1Ø/ 240V
(N)15A
2P
SUM OF ALL BREAKERS IN SERVICE PANEL
TO BE EQUAL TO SERVICE PANEL RATING
PER 2016 CEC 705.12(D)(2)(3)(c)
RELOCATE ALL LOADS
LESS THAN 30A IN
(E) SERVICE PANEL TO
(N) LOAD PANEL
(N)150A
1Ø
240V
(E) TESLA
BACKUP GATEWAY
LARGE LOAD PANEL
(N)AC DISTRIBUTION PANEL
125A/ 1Ø/ 240V
CUTLER-HAMMER: BR816L125RP
(N)90A
2P
(N)40A
2P
(N)60A2P(N)60A2P
(E)40A
2P
RELOCATE ALL LOADS
GREATER THAN 30A IN
(E) SERVICE PANEL TO
(N) LOAD PANEL
(N)150A
LOAD PANEL
(N)AC DISTRIBUTION PANEL
225A BUS/ 1Ø/ 240V
CUTLER-HAMMER: BR4242B225R
(N)60A
2P
LOAD RELOCATION
SUM OF ALL OCPD SHALL
NOT EXCEED AMPACITY OF
BUSBAR IN ACCORDANCE
WITH CEC 705.12(D)(3)(c)
SUM OF ALL OCPD SHALL
NOT EXCEED AMPACITY OF
BUSBAR IN ACCORDANCE
WITH CEC 705.12(D)(3)(c)
(N)20A
2P
(N)15A2P
(N)20A
2P
(N)20A
2P
(N)15A
2P
10FT RULE
LOAD SIDE TAP
LOAD SIDE CONNECTION PER CEC
2016 ARTICLE 240.21(B)(1)
[N1]:SOLAR INVERTER
INSTALLED IS A SMART
INVERTER PER CALIFORNIA RULE
21.
ENH202
ENH202
(N)CAT-5
DISTANCE:
SINGLE LINE
DIAGRAM
NTS
ELECTRICAL LINES AND SYMBOLS
PHOTOVOLTAIC
PANEL
INTEGRATED
INVERTER AC
MODULE
GROUNDING
ELECTRODE
EQUIPMENT
BOND
INVERTER
#
#
#
SPLICE POINT 2 POLE CIRCUIT
BREAKER
AC NON-FUSED
DISCONNECT
AC FUSED
DISCONNECT
MAIN CIRCUIT
BREAKER
SOLADECK ROUTER LINE OF SIGHT
ANTENNA
CAT-5 CABLEWIRE/CONDUIT UNDERGROUND WIRE/CONDUIT
(E)TO HOME SUB-PANEL w/
(3) 3/0 CU
WARNING
UTILITY INTERACTIVE POWER FLOWING
THROUGH THIS PANEL
16.262kW SOLAR GENERATOR
AC OPERATING CURRENT: 67.76A
AC OPERATING VOLTAGE: 240VAC
PHOTOVOLTAIC SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
WARNINGPOWERWALL BREAKERS MUST BE
SWITCHED OFF TO SHUTDOWN SOLAR
CIRCUITS. BREAKER LOCATIONS NEXT
TO SERVICE PANEL.
WARNING
THIS EQUIPMENT FED BY MULTIPLE SOURCES
TOTAL RATING OF ALL OVERCURRENT DEVICES,
EXCLUDING MAIN SUPPLY OVERCURRENT
DEVICE, SHALL NOT EXCEED AMPACITY OF
BUSBAR
Per 2016 CEC 705.12(D)(2)(3)(c)
SHEET
REVISION
1 3 6 2 0 H W Y 9 9
C H I C O , C A 9 5 9 7 3
P H O N E #: (5 3 0 ) 3 4 5 -6 9 8 0
F A X #: (5 3 0 ) 8 9 2 -2 3 6 0
d e s i g n @ s a v i n g e n e r g y f o r l i f e .c o m
PV-4.1
CONSULTANT:
DESIGNER:
J. MIKLES
D. VELAZQUEZ
DATE MODIFIED
SCALE
06/20/2019
H O R N E R , C R A I G
4 9 6 5 L A G O V I S T A W A Y
P A R A D I S E , C A 9 5 9 6 9
A P N :0 5 5 -4 8 0 -0 0 5 P H #: (5 3 0 ) 5 2 0 -0 0 4 1
PER 2016 CEC 690.54 Interactive Point of
Interconnectin installed at all Electrical
Distribution Panel covers that porvide a
path from PV to Utility.
METER
AMPS
PHASE
VOLTS
AMPS
PHASE
VOLTS
AMPS
PHASE
VOLTS
AMPS
PHASE
VOLTS
AMPS
PHASE
VOLTS
WARNING
DUAL POWER SUPPLY
PHOTOVOLTAIC SYSTEM
Per 2016 CEC 705.10, Point of Connection, Located On
Main Service Panel.
SOLAR BREAKER
DO NOT RELOCATE
Solar breaker label @ any breaker passing
Bi-Directional Power
AMPS
PHASE
VOLTS
SUB PANEL
MAIN SERVICE
+-+-
+-+-
+-
+-
+-
+-
+-
+-
+-
+-
+-+-+-+-+-+-
AC PV ARRAY
ELECTRICAL
LABEL
DIAGRAM
BATTERY BREAKER
DO NOT RELOCATE
Battery breaker label @ any breaker passing
Bi-Directional Power
NTS
1
3
°
14'6"
9' 0"
FOOTING
LAYOUT
8'-0" MAX
12'-0" MAX
1 '-9 "
8'-0" MAX
12'-0" MAX
1 '-9 "
±24" DIA.
PEIR FOOTING±16" DIA.
PEIR FOOTING
1 1/2" POST, TYP.
8'-0" MAX
DETAIL B
1 1/2" HOLLAENDER "T", TYP.
PRO SOLAR RAIL
HORIZONTAIL PIPE, TYP.
2'-9"
8'-9"
±2'-3"
±3'-11
±1'-9"
2'-9"
TOLERANCE: XX'-X" ±6"
DETAIL A
HORIZONTAIL
PIPE, TYP.
1 1/2" POST, TYP.
1 1/2" HOLLAENDER "T", TYP.
STANDARD U-BOLT
PRO SOLAR RAIL
SHEET
REVISION
1 3 6 2 0 H W Y 9 9
C H I C O , C A 9 5 9 7 3
P H O N E #: (5 3 0 ) 3 4 5 -6 9 8 0
F A X #: (5 3 0 ) 8 9 2 -2 3 6 0
d e s i g n @ s a v i n g e n e r g y f o r l i f e .c o m
PV-5.0
CONSULTANT:
DESIGNER:
J. MIKLES
D. VELAZQUEZ
DATE MODIFIED
SCALE
06/20/2019
H O R N E R , C R A I G
4 9 6 5 L A G O V I S T A W A Y
P A R A D I S E , C A 9 5 9 6 9
A P N :0 5 5 -4 8 0 -0 0 5 P H #: (5 3 0 ) 5 2 0 -0 0 4 1
NTS
TYPICAL POST
TYPICAL POST
TYPICAL POST
TYPICAL POST
1 '-6 "
(2) #5 CONT.
TOP & BOTTOM
(FOUR TOTAL)
BEDROCK
3/8" DIA. M.B. THRU POST
AT BOTTOM OF FOOTING
6"
TYP.
8 "M A X
3 "
C L R .
1'-9"(2) #5 x 18" LONG REBAR
EMBED 6" INTO BEDROCK
AT 32" O.C.
±1 8 "
±24" DIA.
PIER FOOTING
1 '-4 "
8 "
M A X3" C L R
(2) #5 CONT.
TOP & BOTTOM
(FOUR TOTAL)
#3 TIE AT PEDESTAL
OPTIONAL 12"x12"x6"
PEDESTAL AT COLUMN 6 "M A X
3 "
3/8 DIA M.B. THRU POST
AT BOTTOM OF FOOTING
±16" DIA.
PIER FOOTING
±2 8 "
PIER FOOTING DETAIL ALTERNATE PIER FOOTING DETAIL ALTERNATE SEMI-CONTINUOUS FOOTING
DETAIL
ALTERNATE SEMI-CONTINUOUS FOOTING AT
BEDROCK DETAIL
SIDE VIEW
(2) #5 CONT.
TOP & BOTTOM
(FOUR TOTAL)
(2) #5 CONT.
TOP & BOTTOM
(FOUR TOTAL)
TYPICAL POSTTYPICAL POST
SIDE VIEWSIDE VIEWSIDE VIEW
TOP VIEWTOP VIEWTOP VIEWTOP VIEW
BACK OF ARRAY VIEW
SEE FOOTING
DETAIL
POSTS:
1 1/2" DIA. SCHED. 40
GALV. PIPE, TYP. U.N.O.
1 1/2" HOLLAENDER "T", TYP.
HORIZONTAIL PIPE:
1 1/2" DIA. SCHED. 40
GALV. PIPE, TYP. U.N.O.
PRO SOLAR RAIL
SOLAR MODULES PER PLAN
**MAX HEIGHT 8'-0"
SECTION VIEW