Loading...
HomeMy WebLinkAbout040-310-087 CF ArchiveF L Inspection, Testing, and Maintenance Cover Sheet NFPA 25 as amended by CCR. Title 19 Property Information: NFPA 25 Chapter Number of Forms Name: FAIL* Occupancy/use: 6 OF�Ca i i 5 Address: ❑ Standpipe and Hose Systems Construction Type:{ ❑ Private Water Supply System City: No. Stories: 64�� ❑ Fire Pump g ZIP: `ti 7 Year Constructed: ❑ Water Storage Tank Contact: Telephone. - ❑ Water Spray System 1 10 Contractor Information: Number of System Risers Name: HAYDEN FIRE PROTECTION INC Copy sent to: Address: 15108 JACK PINE WAY ❑ Owner Date City: MAGALIA ❑ Fire AHJ Date State: CALIFORNIA, 95954 ❑ Contractor Date Telephone: (800) 417-0440 NOTES: C-16 827131 1) For specific inspection, testing, arrvd CA License# maintenance requireni:.nts and infonti,ation, see NFPA 25, 2002 Edition as amended by Job # California Code of Regulations, Title 19, 001 to §906. Performed by: (Print) 2) Inspection Items may be performed by the Owner in accordance with California Code of Note: Contractor information may be pre-printed Regulations Title 19 §904.1(a) Forms included with this report NFPA 25 Chapter Number of Forms NIA FAIL* PASS ❑ Automatic Sprinkler System 5 ❑ Standpipe and Hose Systems 6 ❑ Private Water Supply System 7 ❑ Fire Pump g ❑ Water Storage Tank 9 ❑ Water Spray System 1 10 ❑ Foam Water Sprinkler System 11 *See Deficiencies and Comments" section at end of each respective form. State Fire Marshal AES 1 March 21, 2006 ANNEX B Inspection, Testing, and Maintenance Fire Sprinkler System Page 1 of 4 NFPA 25. Chapter 5 as amended by CCR. Title 19 Date of Inspection, Testing, Maintenance: System Riser !D: P 9 f Property information: f ypp Type of System: ��pF CA41, Name: Ga t-0. tit ❑ Wet Pipe ❑ Dry Pipe "� v Address: ❑ Preaction ❑ Deluge City: Main Drain Test Results: Abbreviation Key: I = Inspection Initial Static Pressure: (psi) T = Test M = Maintenance Residual Pressure: W (psi) i A -O = After Operation i Mi = Per Manufacturer's instructions Restored Static Pressure: (psi) Item Activity 3 a Frequency Description NFPA 25 f Reference Fail ! N/A Pass a Daisy P reaction/De uge Valves – Enclosure 2 a 3 I Wee{ Y i temperature i 1.2 Daisy Dry Pipe Valves --cnciosure 12.4.4.1-1 ! Vveeky temperature 1.3 I i i r�ularteri., Gauges (!dry, Preaction; De;uge 5.2.4.2 in � j ! � f I i JyStems. 5.2.4 3„. 1.4 I Quarteriv I Control Valves ( 12.3.2.1 i 1.5 I l Quartery + Alarm Devices 5.2.6 l 1.6 i Quarterly I Gauges (Wet Pipe Systems) 15.2.4.1 I i f 1.7 i i Quarterly I Hydraulic nameplate 5.2.7 1.8 1 ; Quarter y Pipe and Fittings 5.2.2 l ' 1.9 ': Qua;-ter!y I Sprinklers 15.2.1 i ' 1.10 i , Quarterly i Spare Sprinklers 52.1.3 ! 1.11 l Quarterly Fire Department Connections 12.7.1 ! 1.12 ! Quarterly Alarm Valves – Exterior inspection i 12.4.1 1 ! • ! Quarteriv Preaction/Deluge Valves – Exteror1.13 12.4.3.1.6 s i :ns ection j 1.14 f 1 Quarterly Pressure Reducing Valves 12.5.1.1 j 1.15 Quartely Dry Pipe Valves – Exterior 'nspection ! 12.4.4.1.4 i ! Quarteriv 1 Backflow Preventers 12.6.1 j 1.17 j ! Annually j Buildings 5.2.5 j a State Fire Marsha' AES 2 March 21. 2006 25-80 INSPECTION, TESTING.. MAINTENANCE OF WATER-BASED FIRE SYSTEMS' - t State Fire Marsha' AES 2 March 21. 2006 Inspection, Testing, and Maintenance Fire Sprinkler System Page 2 of 4 NFPA 25, Chapter 5 as amended by CCR, Title 19 Date of Inspection; I Testing. Maintenance: i System Riser ID: Property Information: Type of System: � Name: Address: a D. ❑ ❑ ,p�`�<,��2r Wet Pipe "L'r' Dry Pipe "'; v Preaction ❑ Deluge I Cir. I item Activi Fre uenc q Y Descr tion p NFPA 25 Reference =FailN/A Pass 1.18 l Annually I Hangers 5.2.3 i I 1.19 1 Annually Seismic Braces 1.20 1 '5 Years —1-5.2.3- Hangers (Accessible concealed spaces) 1 5.2.3.3 i 1.21 j i 5 Years ( Seismi c Braces (Accessibie concealed 52.3.3 I spaces j 1.22 j l j 5 Years Pipe and Fittings (Accessible concealed spaces) 5.2.2.3 ! i 1.23 j i 5 Years Sprini iers (Accessible concealed spaces) i 5.2.1.1.4 i 1.24 ! 1 4 5 Years i Alarm Valves - Interior Inspection ! 12.4.1.2 i I 1.25 l 5 Years i Hann Valves - Shiners, filters, orifices 1 zAA .z 1.26_ __ 5 Years aptlnteriorinspect-o-n 1%.4.2.1 - - o Years rr�actionrDeou e Varves - Interior Inspection -- i 12.4.3.1 .7 i 1.28 5 Years PreactiontDeluge Valves - Strai Strainers, 12.4.3.1.8 fi- —f— -T- - - ' I I !filters, orifices I 129 I 5 Years I Dry Pipe Valves - interior Inspection 12.4.4.1.5 I �� 1.30 ! 1 ! 5 Years It Dry Pipe Valves - Strainers, filters, orifices j 12.4.4.1.6 I l 2.1 T Annually Alarm Devices (90 Serf c ' 0 5.3.3 12.2.7 ! I j 2.2 T ! Annually Main Drain Test (Enter data on Page 1) ! 12.2.6 12.2.6.1 i 12.3.3.4 2.3 T Annually Antifreeze Test 1 5.3.4 2.4 T --T Annually Control Valve - Posfion 12.3.3.1 2.5 1 Annually Control Valve - Operation 2.6 Annually j Supervisory j 12.3.3.5: 2.7 1i T i Annually Preaction Valve- Priming V`tilater ' ":2.4.3.2.1 I I I ; I 2.8 T ; Annually! Preaction Vaive - Low Air Pressure Alarm j 12.4.3.2.10 2.9 T Annually Preaction Valve - Fu:. Flow Trp Test ! 12.4.3.2.2 - t State Fire Marsha' AES 2 March 21. 2006 U' .. ANNEX B 25-81 Inspection, Testing, and Maintenance Fire Sprinkler System Page 3 of 4 NFPA 25, Chapter 5 as amended by CCR, Title 19 Date of Inspection, Testing, Maintenance: System Riser ID: Property Information: Name: nr. (• Type of System:_ -A 1 El Wet Pipe c�°9?''/j. ❑ Dry Pipe Address: ❑ Preaction,`. ❑ Deluge City: Item Activity Frequency Description NFPA 25 Fail N/A Pass Reference 2.10 T Annually Dry Pipe Valve — Priming Water 12.4.4.2.1 2.11 T Annually Dry Pipe Valve — Low Air Pressure 12.4.4.2.6 Alarm 2.12 T Annually Dry Pipe Valve — Quick -Opening 12.4.4.2.4 Device 2.13 T Annually Dry Pipe Valve — Trip Test 12.4.4.2.2 2.14 T Annually Backflow Preventer Assemblies 12.6.2 2.15 T 3 Years Dry Pipe Valve — Full Flow Trip Test 12.4.4.2.2.2 2.16 T 5 Years Gauges 5.3.2 2.17 T 5 Years Pressure Reducing Valve 12.5.1.2 2.18 T 5 Years Fire Department Connection Backflush 12.7.4 2.19 T 5 Years Sprinklers — Extra High Temperature 5.3.1.1.1.3 2.20 T 5 Years Sprinklers — Corrosive environment or 5.3.1.1.2 corrosive water 2.21 T 10 Years Sprinklers - Dry 5.3.1.1.1.5 2.22 T 20 Years Sprinklers - Fast Response 5.3.1.1.1.2 2.23 T 50 Years Sprinklers 5.3.1.1.1 2.24 T 75 Years Sprinklers 75 years in service 5.3.1.1.1.4 225 I T Sprinklers ri kace lmanufactured prior to 1920 5-3.1.1.1.1 3.1 M Annually Control Valves 12.3.4 3.2 M Annually Preaction/Deluge Valves 12.4.3.3.2 3.3 M Annually Dry PipeValves/Quick-Opening 12.4.4.3.2 Devices F3-4 M Annually Dry Pipe Valve — Low Point Drains 12.4.4.3.3 i 3.5 M i 5 Years Obstruction investigation Chapter 13 State Fire Marshal AES 2 March 21. 2006 25-82,. INSPECTION, TESTING, ANo MAINTENANCE OF WATER-BASED FIRE PriOTECTION SYSTEMS Item Inspection, Testing, and Maintenance Fire Sprinkler System NFPA 25, Chapter 5 as amended by CCR, Title 19 Page 4 of 4 Date of Inspection, Testing, Maintenance.- System Riser ID: Property Information: CAj_j' Name: Type of System: ❑ Wet Pipes ❑ Dry Pipe OF ;D Address: ❑ Preaction�3;.. amu. ❑ Deluge '��F�_�a,;�Z',.•� City: Item Deficiencies and Comments: Deficiencies and Comments Item number must correspond to the Item number of the Activity listed above: 6 d I or— `��Z�� YITSeeContinuation Page(s) (Indicate the number of continuation pages) ❑ PASS ❑ FAIL Signature Date State Fire Marshal AES 2 March 21, 2006