Loading...
HomeMy WebLinkAbout005-417-016 CF ArchiveBUTTE COUNTY FIRE DEPARTMENT/CDF FIRE TITLE 19/24 FACILITY INSPECTION INSPECTION NO. 1 ' 2 3 REINSPECT:1-1 YES T •.� NO Facility r' <'-' ' Occupancy Address Inspector Phone Station.1'` Contact Station Phone Compliance: Yes =-�f ACCESS -- All inspections Address correct/posted and visible from road (Butte co Code 32-9) Access to public street or 20 ft. wide lane (T19-3.05) Gates wide enough to admit fire apparatus (r19-3.16) ' J Fire protection equipment visible/accessible (T19-3.14) PORTABLE FIRE EXTINGUISHERS --All Inspections No = 0 Not applicable = N/A Extinguishers have current annual service tag (r19 -575.1A) Maximum travel 75 ft. (T19-567) Provide clear access to fire extinguisher (T19-563.2) ^Extinguishers mounted on wall/or in cabinet, visible and signed (r19-563.8) EXITS -- All Inspections Exits not obstructed (r19-3.11) !�-%Exit signs in place (CBC 1003.2.9.1) Doors operate without key or special knowledge (CFC 1207.3) Rooms with Occupant Load of 50 Persons or More Exit illumination and signs in place (CBC 1003.2.8:2) Maximum occupancy sign in place (T19-3.30) Two exit doors/panic hardware swing in direction of travel (CFC 2501.8.2) HOUSEKEEPING —All Inspections No waste or rubbish accumulation inside or outside T19-3.14) - Reduce storage to at least "below ceiling/ sprinklers (T193.14) / --'-Remove combus. storage from heater, mech., elect. room (rig -3.19x) Provide approved metal container for oily rag storage (T-19-3 19c) Flammable liquids stored properly (r-19-3.15) Corrections"anti Comments The above deficiencies must be corrected within ELECTRICAL --All inspections Extension cords do not replace permanent wiring (CEC-400-8(1)) Extension cords do not pass through doors/walls (CEC-400-8 {2,3)) 30 inch clearance around all electrical panels (CEC-110-16A) All panels and breakers are marked (CEC-110-17 C) Repair holes in fire -resistive construction CEC (300-21,22) Multi -plug power strips have circuit breaker (CEC 400-13) FIRE PROTECTION EQUIPMENT -- All Inspections Hood system serviced/tagged every 6 mo. by cert. tech. (r19-904) Clean filters, hood, and duct area over cooking appliances (CFC 1006.2.8) Maintain extinguishing systern�-(T19,3:24) Provide spare spribkler heads (6 min.) and/or sprinkler wrench (r19-904.5) Replace damage4, corroded, or painted sprinkler heads (T19-904.5) Identify sprinkler valves and secure in open position (r19-904.5) Replace missing caps on fire department connection (T19-904.3) Provide 5 -yr. certification test for sprinkler/standpipe (r19-904) MECHANICAL EQUIPMENT -- All Inspections vents and chimneys -- No obvious hazards (CMC -Ch. 8) SMOKE DETECTORS -- Day Care Sr. Res., Hospitals, Apts. +. /-Properly installed and tested (r19-749.754) SCHOOLS, JAILS AND HOSPITALS Decorations and curtains fire retardant (r19-3.08) LPG tanks fenced with locked gates (r19-3.22) FIRE DRILLS -- School and Day Care (Title 19-3.13) All systems operable/hooked to office Held monthly (elementary schools) Held semi-annually (high schools) Evacuation plans posted in all rooms Emergency procedures posted in office Teachers take roll books days. Inspection Date: ✓ -� / ! CC-- J .o+ L�llIil BUTTE CO NT"t FIRE DEPARTMENTICDF FIRE �TITLE 19/24 FACILITY INSPECTION INSPECTION NO. ? 3 REINSPECT: YES Nb Facility C .�'r1. Occupancy Address O/D ` - �/&L inspector Phone sr2 9— 7 SrG Station Contact �i / 9X Station Phone Compliance: Yes =✓ No = 0 Not applicable = N/A ACCESS --All inspections ✓/ Address correct/posted and visible from road (Butte Co. Code 32-9) Access to public street or 20 ft. wide lane ;T19-3.05) Gates wide enough to admit fire apparatus (T19-3.16) _Fire protection equipment visible/accessible (T19-3.14) PORTABLE FIRE EXTINGUISHERS -- All Inspections Extinguishers have current annual service tag ,719-575. 1 A) Maximum travel 75 ft. (T19-567) 1/� Provide clear access to fire extinguisher 719-ss3.2) r _Extinguishers mounted on wail/or in cabinet, visible and signed 719-563 8) EXITS -- All Inspections Exits not obstructed (T19-3.11) l Exit signs in place (CBC 1003.2.9.1) /V Doors operate without key or special knowledge ;CFC 1207.3) f Rooms with Occupant Load of 50 Persons or More Exit illumination and signs in place (cec 1003.2.8.2) ELECTRICAL —All inspections (,,E9ension cords do not replace permanent wiring ,1cFc_400_3(1)) 'Extension cords do not pass through doors/walls ;CEc-400-8 M,3}) [/ 0 inch clearance around 311 electrical panels CEC-110-16A) All panels and breakers are marked (CEC-110-17 C) -Repair holes in fire -resistive construction CEC ;300-21,2) 1,,mu iti-piug power strips have circuit breaker tCEC 400-13) FIRE PROTECTION EQUIPMENT -- All Inspections Hood system serviced/tagged every 6 mo. by cert. to . J19-904) 19-904) Clean filters, hood, and duct area over cookin ppliances (CFC 1006.2 s) Maintain extinguishing yst ms 19-3 Provide spare sprin ler a s in.) an sprinkler wrench (119-904 5) Replace damag d co r ed, or painted sprinkler heads (719-904.5) Identify sprinkle iv s and secure in open position (T19-904 5) Replace " ing caps on fire department connection JT19-904 3) P 1 5 -yr. certification test for sprinkler/standpipe (T19-904) MECHANICAL EQUIPMENT -- All Inspections t.,..::�'Vents and chimneys -- No obvious hazards (CMC -Ch. s) Maximum occupancy sign in place (r19-3.30) SMOKE DETECTORS -- Day Care Sr. Res., Hospitals, Apts. Two exit doors/panic hardware swing in direction of travel (C -FC 2501.8.2) X/,, 4roperly installed and tested (T19-749, 754) HOUSEKEEPING —All Inspections No waste or rubbish accumulation inside or outside 119-3.14) ✓' Reduce storage to at least "below ceiling/ sprinklers 719-3.14) � Remove combus. storage from heater, meth., elect. room ,T19 -3.19f) "Provide approved metal container for oily rag storage T-19-3.190 / _Flammable liquids stored properly (T-19-3.15) Correcti ns and Comments A - ,of, r; �— SCHOOLS, JAILS AND HOSPIT LS Decoratio s an s fire retardant (T19-3.08) LPG t fe ed with locked gates 81 9.3.22) FIRE DRILLS -- School and Day Care (Title 19-3.13) All systems operable/hooked to office Heid monthly ( ementary scho Held semVan schools) Evacu posted in all rooms E envy rocedures posted in office Teachers take roll books / t l/ he above deficiencies must be corrected within-7days. inspection Date. AP # wnerllVianag er e--