HomeMy WebLinkAbout009-121-011 CF ArchiveFIRE SAFETY INSPECTION REPORT Butte County Fre Department California Department of Forestry and Fre Protection Oroville, California 95965 • (530) 538-7888 Business Address: City. Business Name: Owner/Property Management: Inspection Date: Business Phone: AP#: NO. CORRECTIONS REQUIRED NQ LOCATION I REMARKS CLEAR® � LOCATION 1 Provide adbess numbasbAdT I.D. visible from street EXITING 2 Remove obstructions at axils, doors, aisles, stairways, etc. 3 Exit door to open without a key or any speak krmledgel effort. I I 4 Repair exit door hardware. 5 Remove obstrutions from door required to be closed 6 Remove bclwla dm from doors with panic hardware. 7 Provide sign over main exit door -'This door to remain unlocked during business hours". 8 Remove storage from under unprotected staff 9 Provid0maintain eadt sigglemergericy fighting. FIRE EGINGU5HHt5 10 Have fire s serviced and RE -INSPECTION DATES INSPECTOR 11 Providelmount fire extinguisher as indicated. 1st / / 12 Post a sign indica ' fire ad usher location. 13 Provide clear access to fire ad cher. 2nd / / FIRE PROTECTION EQUVfIENT I 14 Maintain, repair, paint, inspect, ardor test sprinkledstandpipe systemkydranVFDC/PIV. Refer to FPB / / 15 Maintain 3 feet minimum clearance for access/use of fire appliances/equipment. District Attorney / / 16 Replace damage#ainted4nissing sprinkler hea&'FDC caps. Final Clearance / / 17 Provide 5 -year certification test for inklerlsia em. I 0owwwClass ❑ Check Pre -Fire Plan for accu 18 Provide spare spnnMff heads min. ardor wrench. BY ORDER OF THE FIRE CHIEF 19 Hood/duct eDdinguishing system to be serviced/ tagged every 6 mo. 20 Remove grease from hood, duct, and filters. KEEP CLEAN) You are hereby notified to correct all violations immediately or show cause FIRE ALARM SYSTEMS why you should not be required to do so. A re -inspection will be conducted on . Willful failure to comply with this notice is a 21 Maintain, repair, inspect, ardor test fire alarm system. misdemeanor. Violations that are not corrected immediately arid/or remain FIRESEPARATLONS after the reinspection may be processed as a criminal offense. Thank you 22 Repair holo in required fire resistive constriction. for your assistance and cooperation in minimizing the fire and life loss in 23 Providezirepair self or automatic closing fire rated assemblies. your community. 24 Keep attic access and scuttle openings closed. ELECTRICAL Signature of Recipient 25 Discontinue use of extension cords. 26 Install permanent wiring for fixed and stationary appliances. ❑ Owner ❑ Manager ❑ Employee ❑ Other 27 Provide cover plates for all junction boxes. Inspecting Officer. 28 Remove exposed wiring or protect in approved conduit. 29 Provide a 3Nnch clear space to and in front of electrical panel. FPB: Engine Com 30 Maintain winin good condition and protect from damage. p NO VIOLATIONS NOTED THIS DATE THANK YOU FOR BEING FIRE SAFE! FLAMMABLE LIQUIDS+ CONS GASES 31 Provide a flammable liquid storage cabinet or reducestorage to 10 gallons or Additional Comments: less. 32 Remove all flammable liquids not used for maintenance purposes. 33 Store flammable licluids away from exits, stairs, or corridois. 34 Secure compressed gas cylinders. STORAGE + HOUSEKEEPING 35 Anange storage in an orderly manner to provide access/ 36 Remove combustible storage from water heater and electrical room. 37 Remove storage to 24 irches below ceiling or 18 inches below sprinkler heads. 38 Remove lini/debm from behind washers and dryers. 39 Remove waste/rubbish mai rials from ft premises. 40 Keep dumpsters 5 feet away from combustible walls, eaves, or openings. MISCELLANEOUS 41 1 Other violations ardor comments. = Page_ of