HomeMy WebLinkAbout062-250-026ELECTRICAL CONTRACTORS lawwk ,.t Fire Alarm Submittals for: CAMP OKIZU INFIRMARY BERRY CREEK, CA. /,, �, -2- � QUICK SERVICE CONSTRUCTION COMMERCIAL SERVICES AGRICULTURAL SERVICES 36 W. Eaton Road • Chico, CA 95973-0149 • (530) 891-1933 • FAX (530) 891-6749 CA Lic. #454345 • NV Lic. # 45459 • www.chicoelectric.com Model 5895XL Intelligent Power Module 12 The intelligent way to distribute power throughout your installation With 5.0 amps of output power, six programmable FlexputTM 1/0 circuits, and two Form C relay circuits, the Model 5895XL Intelligent Power Module allows you to greatly enhance the capabilities of an IntelliKnight system, distributing power where needed throughout a facility. 5895XL modules connect via the RS 485 system bus. Up to eight 5895XL modules can be used per IntelliKnight system. Each 5895XL has its own optically isolated RS 485 bus to which other modules, such as 5860 remote annunciators and 5824 printer interface modules, can be connected. You can also connect 5815XL SLC expansion modules, adding flexibility and wiring distance. Each 5895XL supports its own backup batteries and monitors the AC power. Model 5895XL Intelligent Power Module The Model 5895XL adds 5.0 amps of power, six Flexput 1/0 circuits, and two Form C relay circuits to an IntelliKnight installation. The 5895XL is optically isolated providing ground loop isolation and transient protection. The 5895XL conditions the RS 485 system bus allowing an additional 6,000 feet of wiring. Operation The green LED on the 5895XL board indicates communication with the IntelliKnight FACP. Features • 5.OA output power • Flexput 1/0 circuits, 3A each, programmable as notification circuits,auxiliary power circuits, or initiation circuits. • Supports Class A configuration for SBUS & Flexput circuits • 2 Form C programmable relays rated at 2.5A at 24 VDC • Ground loop isolation • Transient protection • SBUS repeater conditions the RS 485 signal • 6,000 feet wiring distance from 5895XL (same distance as main FACP) The FlexputTM circuits can be • Large cabinet can house two 17 notification appliance circuits, amp hour batteries continuous power, resettable • UL 864 listed, complies with power, door holder power or NFPA 72 and 101 initiation circuits that can support both 2- and 4 -wire smoke detectors.. All FlexputTM SILENT circuits and relay outputs are KNIGHT individually mappable from the IntelliKnight 5820XL FACP. Model 5895XL Specifications Primary AC 120 VRMS at 60 hz, 2.5A Total Accessory 5A at 24 VDC Load Current: Standby 40 mA Alarm 160 mA 1/0 Circuit 3A per circuit (5A total Power per system) Dimensions 16"W x 26"H x 4.65"D (40.6cm W x 67cm H x 11.8cm D) Mounting Flush or surface Color Red Model 5895X1 Intelligent Power Module Engineering Specifications The contractor shall supply a power module compatible with the IntelliKnight Model 5820XL FACR The power module must have 5.0 amps of output power, Flexput 1/0 circuits rated 3.0 amps each, and two Form C relay circuits rated at 2.5 amps at 24 VDC. The power module shall connect to the main FACP via an RS 485 system bus (SBUS). The power module shall contain an additional RS 485 bus that is completely compatible with all IntelliKnight add-on modules, including 5815XL SLC Expanders, 5860 Remote Annunciators, 5824 Serial/Parallel Modules and addressable devices. The power module RS 485 bus shall be optically isolated providing ground loop isolation and transient protection. The unit shall be an SBUS repeater that conditions the signal driving 6,000 feet of additional wiring. 5895XL Installation Example 5895XL Connection to FACP 5820XL FACP 5895XL 1 FACP23 22 21 20 MAIN SBUS IN/OUT 19 18 17 16 33 32 31 30 23 22 21 20 19 18 17 16 + A B 0000 + A B + A B �Pp00000000 + A B + A B SLC NACs, Aux. power, etc. 5624 5860 Used in Used in To next Class A Class A SBUS device configurations Up to 6,000 feet, non -shielded configurations m rn J W z a z NACs, Aux. power, etc. NACs, Aux. power, etc. 5895XL-1 SBUS 5895XL-2 SBUS 5860 5860 To next 5895XL 5860 5860 5824 SLC SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 612-493-6435 FAX: 612-493-6475 World Wide Web: http://www.silentknight.com MADE IN AMERICA FORM# 350097, Rev. 11/98 Copyright ©1998 Silent Knight IntelliKnight is a Registered Trademark or Silent Knight Flexput is a Trademark of Silent Knight Model 5860 A Remote Annunciator Bring the power to control IntelliKnight® to every area within your facility. Now you can operate and program your IntelliKnight system from up to 8 locations throughout your facility. The Model 5860 Remote Annunciator provides the same advanced, easy-to-use interface found on the IntelliKnight panel's built-in annunciator. The 80 -character display and ergonomically designed keypad allow for simple and error -free system operation. All operations—including reset, silence, detector status checking, fire drill, and programming—are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the IntelliKnight panel via the RS -485 system bus. Depending on wiring methods used, wire runs can be up to 6000 feet from the panel. Model 5860 Users identify themselves to the control panel by entering a code on Remote Annunciator the annunciator or by turning the nm._ The 5860 is designed to look and operate exactly the same as the IntelliKnight built-in annunciator. Features include an 80 -character backlit LCD providing easy -to - understand system messages. The annunciator is ergonomically designed with over -sized buttons for the most frequently used features, like Reset and Silence. In addition to status messages displayed on the LCD, there are five LEDs for alarm, supervisory, trouble, silence, and AC power status. The annunciator is available in gray to match virtually any decor and red for applications where the annunciator must stand out. The annunciator enclosure can be surface or flush mounted. A trim ring kit is available for surface mounting. Operation When the system is normal and receiving AC power, the power LED is lit and all other LEDs are off. Other LEDs turn on as the conditions occur. firefighter's key. when a user t `` presses a button, the annunciator piezo beeps and the LCD prompts the user to enter a code or other 771 , relevant information. _41r1..KLV Multiple users can work at different annunciators simultaneously without affecting each other. Features • 80 -character display • Tactile/audible feedback • Accepts user codes or firefighter's key • RS -485 interface to panel • Can be flush- or surface - mounted. Trim ring available for surface -mounting. • Operation and appearance identical to on -board annunciator • Supports simultaneous use by multiple users • UL listed, complies with NFPA 72 • CSFM Listed • MEA Listed 5860 Remote Annunciator Specifications Operating Voltage: 24 VDC Standby Current: 20 mA Alarm Current: 25 mA Max. per system: 8 Ambient 32°F to 120°F Temperature: (0°C to 49°C) Mounting: Surface or flush Wiring Distance from Up to 6,000 feet IntelliKnight panel: (depending on wiring method) Dimensions: Height: 7-3/8" Width: 9-1/8" Depth: 1-1/2" Colors: Lt. gray (5860) Red (5860R) SILENT KNIGHT Model 5860 Remote Annunciator Engineering Specifications The main control must have a built-in annunciator and must support up to eight remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built-in annunciator. All annunciators must have an 80 -character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. 5860 Block Diagram IntelliKnight Panel Up to 6000 feet from panel (depends on wiring method used). SII.ENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 612-493-6435 FAX: 612-493-6475 World Wide Web: http://www.silentknight.com Model 5860 _ 0 n 0 0 0 a01� C3 13 v Up to 8 devices per system. MADE IN AMERICA FORM# 350320, Rev. 1/98 Copyright © 1998 Silent Knight %., CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECT!.QN �► =FICE OF THE STATE FIRE MARSHAL 0F.T FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE ARSRA` LISTING No. 7170-0559:135 Page 1 of 1 CATEGORY: Control Unit (High Rise) LISTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: Brian Foltz *(763) 493-6400 DESIGN: Models 5820, 5820XL and IFP -1000 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterflow and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 5820/5820XL/IFP-1000 5815/5815XL 7628 Intelliknight 5820 5860/586OR/RA-1000 5897 5824 5895/5895XL/RPS-1000 5865-3/5965-4 5880 AB -33 S D 500 -AN M 50500-LIM 50505-618 Control Unit Analog Loop Expander EOL Resistor Enclosure Annunciator Power Supply Serial/Parallel Interface Power Expander/Supply LED Annunciator LED 10 Module Battery Cabinet Addressable Notification Module Line Isolation Module Isolation Base RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, UL and CSFM label. APPROVAL: Listed as fire alarm control unit suitable for high rise applications when used in conjunction with Model SKE-360 Voice -Tone Evacuation unit (CSFM Listing No. 6912-0559:122), two-way firefighter telephone and separately listed electrically and functionally compatible initiating and indicating devices. This control unit can generate the temporal code pattern fire alarm signal as required per NFPA 72, 1996 Edition. Refer to manufacturer's Installation Manual for details. NOTE: For Fire Alarm Verification Feature (delay of alarm signaling), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 'Rev. 06-21-2000 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 22, 2000 Authorized By: =ffec five issue date to expiration date (2/�� fisting Expires June 30, 2001 BEN HO, Supervising Deputy Program Manager Die Cast Metal Manual Pull Stations Silent Knight die cast metal manual pull stations put quality and peace of mind in easy reach. A manual pull station doesn't have to be fancy—just tough, reliable and extremely easy to operate. Silent Knight's die cast metal pull stations are all three. they're the high-quality choice for fast, sure initiation of a fire alarm signal. Our manual pull stations feature rugged, die cast metal construction that lasts and lasts. they're available in single or dual action models. And Silent Knight manual pull stations are UL -Listed, CSFM Approved, and MEA (BSA) Approved. For outdoor use, a weatherproof model is also available. On your next job, make the high-quality choice—Silent Knight manual pull stations. For more information, or additional information on our complete fire products line, call Silent Knight at 1-800-446-6444, or in Minnesota call (612) 493-6435. Die Cast Metal Manual Pull Stations Silent Knight's line of manual pull stations feature high-quality, die cast metal construction. They are available in either single or dual action configurations with SPST switch, and with wire lead or terminal strip connections. The normally open contact, which closes when the pull station is activated, is rated for 1 amp, at 125 VAC or 30 VDC. The contacts are gold-plated to avoid risk of corrosion. All models in the series have been tested by UL for compliance to the latest requirements of the Americans with Disabilities Act (ADA). Features • UL listed. • CSFM approved. • MEA (BSA) approved. • ADA compliant. • Weatherproof model approved for outdoor use. • Single or dual action. • Terminals or wire leads. • Key reset models use same keys as Silent Knight enclosures. • Surface mount backboxes available. • High -gloss red enamel finish on die cast metal. • Corrosion -resistant gold-plated contacts. Operation The single action pull stations are operated by simply pulling the handle on the front of the Station as far down as it will go, at which point the handle locks into place and is easily visible from up to 50 feet. A scored acrylic break rod is also supplied with each unit for applications where it is necessary. the handle is reset by opening the station with the hex wrench or key, placing the handle in the normal upright position and relocking the station. On the dual action models, pushing the PUSH bar causes it to rotate inward, allowing the PULL handle to be grasped in a one -handed motion. The dual action models are also supplied with break rods. Dual action models are reset in the same way as a single action model. The weatherproof version of the pull stations is provided with a gasket and die cast metal backbox tapped on one end for 1/2" conduit, for surface mounting. Single Action Pull Station Dual Action Pull Station SILENT KNIGHT Die Cast Metal Manual Pull Stations Specifications Switch Rating: 1 amp at 125 VAC, or 30 VDC. Pull Station Dimensions: 4-314" H x 3-114" W x 1-118" D Surface Mount Backbox Dimensions: 4-314" H x 3-114" W x 2-114" D (cast and sheet metal). Color: Red with raised white letters, white PULL bar with raised red letters. Accessories: All models are supplied with one scored- acrylic break -rod and one hex wrench or key. Ordering Information Model Description PS-SATK Pull Station, Single Action, Terminal Connection, Key Reset PS-SAWH Pull Station, Single Action, Wire Leads, Hex Reset PS-DATK Pull Station, Dual Action, Terminal Connection, Key Reset PS-SATK-WP Pull Station, Single Action, Terminal Connection, Key Reset, Weatherproof Box PS -WPB Weatherproof Box PS -BB Back Box PS -GR -12 Box of 12 Scored Acrylic Break Rods To Fire Alarm Control Panel Wiring Diagram - Terminal Screw Terminals To Next Device or ELR 3SILENT 0 KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 612-493-6435 FAX: 612-493-6475 World Wide Web: http://www.silentknight.com Wiring Diagram - Wire Leads To Fire Alarm Control Panel s text ice LR MADE IN AMERICA FORM# 350792, Rev. 4198 Copyright © 1998 Silent Knight � CILL+f0N1, CALIFORN"'A, DEPARTMENT OF FORESTRY & FIRE PROT ION ° OFFICE OF THE STATE FIRE MARSHAL Q °F FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No CATEGORY LISTEE: 7150-0559:121 Boxes/Pull Stations Page 1 of 1 Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Brian Foltz *(763) 493-6400 DESIGN: Models PS-DATH, PS-DATK, PS-SATH, PS-SATK and PS-SAWH non coded manual pull stations with hex lock or key lock. Model with suffix -DATH or - DATK indicates push bar type and suffix -SATH, -SATK or -SAWH indicate no push bar type, followed by 0 (outdoor, has gasket) or I (indoor, no gasket). Model *PS -WPB back box (for outdoor) and Model PS -BB back box (for indoor) must be installed with the unit. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed and compatible fire alarm control units. Suitable for indoor and outdoor use. XLF: 7150-1408:107 'Rev. 06-21-2000 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Issued: JUNE 21, 2000 Authorized By: ive issue date to expiration date isting Expires June 30, 2001 I� BEN HO, Supervising Deputy Program Manager wheeloex VCJM Air (E , �1`111Z kA INC. Description 0031111111 H° FIRE ALARM SYSTEMS Wheelock's Series NS/NS4 Horn Strobe appliances and the Series NH Horn are of LOW CURRENT design with ZERO INRUSH. The horn appliances provide a selectable continuous horn tone or temporal pattern (Code 3) tone when constant voltage from a Fire Alarm Control Panel (FACP) is applied. Each tone has two dB settings to choose from. All models (horn only or horn with strobe) may be synchronized when used in conjunction with the Series SM or DSM Sync Module(s) or Wheelock's PS -12/24-8 Power Supply with Wheelock's Patented Sync Protocol. Additionally, the horn may be silenced while maintaining strobe activation of the Series NS/NS4 Horn Strobe appliances. All of these features are achievable with either Wheelock's Patented 2 Wire Series NS or with the 4 wire Series NS4 (Audible will operate only with power applied to both strobe and audible). The Series NS/NS4 Horn Strobe appliances and NH Horn appliances are designed for maximum performance, reliability, and cost-effectiveness while meeting or exceeding the latest requirements of NFPA 72 (National Fire Alarm Code), ANSI 117.1 (American National Standard for Accessible and Usable Buildings and Facilities) and UL Standard 1971 (Standard for Signaling Devices for The Hearing Impaired) and UL 464 (Audible Signal Appliances). Series NS/NS4 Audible Strobe appliances, when properly specified and installed in accordance with NFPA/ANSI standards can provide the Equivalent Facilitation allowed under ADA Accessibility Guidelines (ADAAG General Section 2.2) by meeting or exceeding the illumination which results from the ADA specified strobe intensity of 75 candela at 50 feet. This is an illumination of .030 lumens per square foot. When used with the Wheelock Series SM or DSM Sync Modules or Wheelock's PS -12/24-8 Power Supply with Wheelock's Patented Sync Protocol, the continuous horn tone produces a synchronized temporal (Code 3) tone (required by NFPA-72 (1999)). This ensures a distinct temporal (Code 3) pattern when multiple horns are within hearing distance. If not synchronized, the temporal sound could overlap and not be distinctive. At the same time the strobes on the circuit may be synchronized. This provides the ability to comply with ADA recommendations concerning photosensitive epilepsy and meet NFPA requirements when installing multiple appliances within the field of view. All of this plus the ability to silence the horn is achieved by using only 2 WIRES (NS/NH). Copyright 1999 Wheelock, Inc. All rights reserved. SERIES NS/NS4 HORN STROBE APPLIANCES e SERIES NH HORN APPLIANCE SERIES NS/NS4 Features SERIES NH • Approvals Include: Underwriters Laboratories UL 1971 and UL 464 Listings, FCC Part 15, California State Fire Marshal (CSFM), New York City (MEA), Factory Mutual (FM) and Chicago (BFP). • ADA/NFPA/ANSI compliant. Meets OSHA 29 Part 1910.165. • Low Current. • Zero Inrush. • Wall mount only. • 2 Selectable tones and dB levels. • Continuous tone: anechoic, 90 or 95 dB; reverberant, 82 or 88 dB @ 24 VDC. • Temporal Code 3 tone: anechoic, 90 or 95 dB; rever- berant, 75 or 82 dB @ 24 VDC. • Patent Pending Universal Mounting Plate for single gang, double gang, 4" square, 100 mm European backboxes or Wheelock's SHBB shallow surface backbox. • Notification Appliance Trim Plate (NATP) is available for use when there is open space between the finished wall and the flush backbox. • Available with 15, 15/75, 30, 75 and 110 cd strobe intensities. • 15/75 candela wall mounted strobes are listed at 15 candela under UL Standard 1971 and meet 75 candela intensity on axis for ADA guidelines. • 2 versions available. • 2 -wire for both horn and strobe. • 4 -wire model. • Non -Sync and Sync in one (synchronization requires the Series SM or DSM Sync Module or Wheelock's PS -12/24-8 Power Supply with Wheelock's Patented Sync Protocol). • Matching horn in 12/24V (Selectable). NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in BOLD CAPITAL LE r .6RS. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum from 20-31 VDC (for 24 VDC models) or 10.5-15.6 VDC (for 12 VDC models). Note that NFPA-72 (1999) specifies a flash rate of 1 to 2 flashes per second and ADA guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL 1971. • Series NS/NS4 Horn Strobe products are Listed under UL 1971 for indoor use with a temperature range of 32° F to 120° F (0° C to 49° C) and maximum humidity of 85%. • Series NH horns are Listed under UL 464 for audible signal appliances. Specifications and Ordering Information WALL MOUNT ONLY Model Number* Order Code Input Voltage Strobe Candela Mounting Options** NS -2415W -FR 7805 24 15 B,D,E,F,G,H,J,O,R,S,X NS -241575W -FR 7806 24 15/75 B,D,E,F,G,H,J,O,R,S,X NS -2430W -FR 7807 1 24 30 B,D,E,F,G,H,J,O,R,S,X NS -2475W -FR 7808 24 75 B,D,E,F,G,H,J,O,R,S,X NS -24110W -FR 7809 24 110 B,D,E,F,G,H,J,O,R,S,X NS -1215W -FR 7815 12 15 B,D,E,F,G,H,J,O,R,S,X NS -121575W -FR 7816 12 1 15/75 B,D,E,F,G,H,J,O,R,S,X NS4-2415W-FR 7900 24 15 B,D,E,F,G,H,J,O,R,S,X NS4-241575W-FR 7901 24 15/75 B,D,E,F,G,H,J,O,R,S,X NS4-243OW-FR 7902 24 30 B,D,E,F,G,H,J,O,R,S,X NS4-2475W-FR 7903 24 75 B,D,E,F,G,H,J,O,R,S,X NS4-24110W-FR 7904 24 110 B,D,E,F,G,H,J,O,R,S,X NS4-1215W-FR 7910 12 15 B,D,E,F,G,H,J,O,R,S,X NS4-121575W-FR 7911 12 15/75 B,D,E,F,G,H,J,O,R,S,X NH -1 2/24-R 7449 12/24 - B,D,E,F,G,H,J,O,R,S,X SYNC MODULE*** N84-1215W/NH NS4.121575W/NH Average Current 10.5 VDC SM -1 2/24-R 6369 12 .014 W 0.014 24 .025 W DSM -1 2/24-R 6374 12 .020 W Voltage NS4.1215W/NH 24 .038 W NOTES: Model # Color is Red, can be ordered in White, Call Customer Service for order code & delivery. Model Code Suffix: W = wall, F = fire lettering or call Customer Service if other lettering is required (Ex. Feugo), R = red, W at end = white, 4 = 4 wire Example: NS -2415W -FR Red NS2415W-FRE--Red NS-2475W-FW--'K--white Wall ire WaTI'-Fire Fires 4 -Wire `* Refer to Data sheet S7000 for mounting options. SM Sync Modules are rated for 3.0 amperes at 12 or 24 VDC; DSM Dual Sync Modules are rated for 3.0 amperes per circuit. The maximum number of interconnected DSM modules is twenty (20). Refer to Data Sheet S3000 or installation instruction (P83123 for SM or P83177 for DSM). *12 VDC model set on Code 3 - Low does not meet the 75 dBA minimum UL Reverberant Sound level required for Public Mode Fire Protection Service. Series NS *Average Current (Amperes) At 2 Audible Settings @ 20, 24, 31 & 10.5, 12 and 15.6 VDC dBA Ratings For Series NS/NS4/NH Horn Voltage Description Volume Reverberant dBA @ 10 H per UL 464 Anechoic dBA @ 10 It 12 VDC 24 VDC 12 VDC 24 VDC Continuous Horn High 82 88 89 95 Low 76 82 84 90 CODE 3 Horn High 76 82 89 95 Low 70* 75 84 90 *12 VDC model set on Code 3 - Low does not meet the 75 dBA minimum UL Reverberant Sound level required for Public Mode Fire Protection Service. Series NS *Average Current (Amperes) At 2 Audible Settings @ 20, 24, 31 & 10.5, 12 and 15.6 VDC *Average Current - with Hi dBA Setting (95 dBA) 24 volt models Voltage NS -2415W NS -241575W NS -2430W NS -2475W NS-2411OW 20.0 VDC 0.078 0.094 0.108 0.177 0.219 24.0 VDC 0.072 0.086 0.097 0.155 0.185 31.0 VDC 0.070 0.081 0.088 0.129 0.153 `Average Current - with Low dBA Setting 90 dBA 24 volt models Voltage NS -2415W NS -241575W NS -2430W NS -2475W NS-2411OW 20.0 VDC 0.071 0.089 0.100 0.173 0.210 24.0 VDC 0.065 0.080 0.087 0.145 0.174 31.0 VDC 0.059 0.068 0.077 0.118 0.141 *Average Current -with Hi dBA Setting 95 dBA 12 volt models Voltage NS -1215W NS -121575W 10.5 VDC 0.158 0.204 12.0 VDC 0.137 0.175 15.6 VDC 0.109 0.133 *Average Current - with Low dBA Setting 90 dBA 12 volt models Voltage NS -1215W NS -121575W 10.5 VDC 0.156 0.199 12.0 VDC 0.133 0.170 15.6 VDC 0.104 0.128 Average current per actual Wheelock Production Testing @ 10.5, 12, 15.6, 20, 24 & 31 VDC. For rated average and peak current across the UL listed voltage range for both filtered DC and unfiltered VRMS, see Installation Instructions (P83518). Series NS4/Series NH Horn *Average Current - Strobe Only Input 24 volt models Voltage NS4-2415W NS4-241575W NS4-2430W NS4.2475W NS4-24110W 20.0 VDC 0.064 0.080 0.095 0.157 0.199 24.0 VDC 0.054 0.068 0.081 0.133 0.161 31.0 VDC 0.047 0.056 0.066 0.108 0.131 *Average Current - Input with Hi dBA Setting Horn Only NS4/NH 95 dBA 24 volt models Voltage NS4-2415W NS4-241575W NS4-2430W I NS4-2475W I N84-2411OW 20.0 VDC 0.020 0.020 0.020 0.020 0.020 24.0 VDC 0.027 0.027 0.027 0.027 0.027 31.0 VDC 0.034 0.034 0.034 0.034 1 0.034 *Average Current - Input with Low dBA Setting Horn Only NS4/NH 90 dBA 24 volt models Voltage NS4-2415W NS4-241575W NS4-2430W NS4.2475W NS4-24110W 20.0 VDC 0.016 0.016 0.016 0.016 0.016 24.0 VDC 0.021 0.021 0.021 0.021 0.021 31.0 VDC 0.026 0.026 0.026 0.026 0.026 *Average Current - Strobe Only Input 12 volt models Voltage NS4-1215W NS4-121575W 10.5 UDC 0.148 0.189 12.0 VDC 0.126 0.162 15.6 VDC 0.102 0.130 *Average Current - Horn Only NS4/NH Input with Hi dBA Setting 95 dBA 12 volt models Voltage N84-1215W/NH NS4.121575W/NH 10.5 VDC 0.013 0.013 12.0 VDC 0.014 0.014 15.6 VDC 0.020 0.020 *Average Current - Input with Low dBA Setting Horn Only NS4/NH 90 dBA 12 volt models Voltage NS4.1215W/NH NS4-121575W/NH 10.5 VDC 0.008 0.008 12.0 VDC 0.009 0.009 15.6 VDC 0.011 0.011 Average current per actual Wheelock Production Testing @ 10.5, 12, 15.6, 20, 24 & 31 VDC. For rated average and peak current across the UL listed voltage range for both filtered DC and unfiltered VRMS, see Installation Instructions (P83518). SERIES NS/NS4//NH QUICK REFERENCE GUIDE Model Number* Wall Mount Non- Sync Sync's w/SM/DSM or PS12 24-8 Strobe Candela 24 VDC 12 VDC 2 Wire 4 Wire NS -2415W -FR X X X 15 X SIGNAL X NS -241575W -FR X X X 15/75 X X NS -2430W -FR X X X 30 X X NS -2475W -FR X X X 75 X X NS -24110W -FR X X X 110 X X NS -1215W -FR X X X 15 X X NS -121575W -FR X X X 15/75 X X NS4-2415W-FR X X X 15 X X NS4-241575W-FR X X X 15/75 X X NS4-2430W-FR X X X 30 X X NS4-2475W-FR X X X 75 X X NS4-24110W-FR X I X I X 110 X X NS4-1215W-FR XX X 15 X X NS4-121575W-FR X X X 15/75 X X NH -12/24-R** X X X X X X Model # Color is Red, can be ordered in White, Call Customer Service for order code & delivery NH -12/24 can also be ceiling mounted. A WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS"(P83518) AND "GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTATIONS DO UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: • TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM PRIMARY AND SECONDARY POWER SOURCES. • FUSE RATINGS ON NAC CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. • COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. • THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED INPUT VOLTAGE RANGE. • INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. • INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. • USE SERIES NS/NS4/NH ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE SERIES NS/NS4/NH ON CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBE MAY NOT FLASH. • FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. • CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wiring Diagrams# NS APPLIANCE NON -SYNCHRONIZED To FROM + PRECEDING + NEXTAPPLIANCE OR END OF LINE APPLIANCE — — RESISTOR ORFACP (EDLR) SIGNAL NS AND NH APPLIANCES SYNCHRONIZED WITH DSM MODULE DUAL CLASS "A" NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE DSM e SYNC + O SYNC OUT 1 + IN 1 NS 4 NS 4 NH a MINUS 1 IF AUDIBLE + AUDIBLE A NAC C CIRCUIT P OUT - AUDIBLE + CUT 2 S 4 NS 4 NH Q + IN 2 N AUDIBLE NAC MINUS 2 CIRCUIT RETURN NS APPLIANCE SM SYNCHRONIZED WITH SM MODULE SINGLE STROBE SIR BE CLASS "B" NAC """'"`UIT SEBOBE CIRCUIT WITH FCUT AUDIBLE SILENCE c � RB a "S RS DLR FEATURE P ADDIBLE AUDIBLE NAC EDLR' CIRCUIT AUDIBLE NS4 (4 wire) Appliance Independent Operation of Audible Signal and Strobe* FROM FIRE ALARM CONTROL PANEL TO NEXT APPLIANCE (FACP), OR END -OF -LINE PRECEDING APPLIANCE 't + RESISTOR (EDLR) OR SYNC MODULE' - + STROKE AUDIBLE FROM DING OR S+ +1 TO NEXT APPLIANCE PRECEDING APPLIANCE OR EDLR #For Wiring Information on the PS -12/24-8 Power Supply, please refer to Data Sheet #S9001 *Series NS4 Note: Audible will operate only with power applied to both strobe and audible. Note: NS/NS4/NH must be set on Code 3 horn tone to achieve synchronized temporal (code 3) tone. Refer to Installation Instruction (P83518, P83601, P83600 respectfully). * Value determined by FACP NAC Circuit(s). Refer to Series SM/DSM data sheet S3000 or installation instructions (P83123 for SM or P83177 for DSM). Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Architects and Engineers Specifications The notification appliance(s) shall be Wheelock Series NS/NS4 Horn Strobe and Series NH Horn appliances and companion Series SM and DSM Sync Module(s) or Wheelock's PS -12/24-8 Power Supply with Wheelocks Patented Sync Protocol, or approved equals. Series NS/NS4 appliances shall be listed under UL Standard 1971 (Emergency Devices for the Hearing Impaired for Indoor Fire Protection Service). Series NH Audible Horn, Series SM and DSM Sync Modules shall be UL listed under Standard 464 (Fire Protective Signaling). Series NS/NS4/NH, Series SM and DSM shall be certified to meet FCC Part 15, Class B. The appliances shall be designed for 2 or 4 -wire operation and shall provide either a continuous horn/tone or temporal (Code 3) tone when constantly applied voltage from a Notification Appliance Circuit (NAC) of the Fire Alarm Control Panel (FACP) or synchronized temporal (Code 3) horn and synchronized strobe when used in conjunction with the Series SM or DSM Sync Module(s) or Wheelocks PS -12/24-8 Power Supply with Wheelocks Patented Sync Protocol. When utilizing the Series NS4 in an independent (separate strobe and audible NAC circuits) operation, power shall be applied to both strobe and audible in order to have the audible portion of the Series NS4 operate. Series NS shall be designed so that the horn tone may be silenced while maintaining strobe activation (when used with the Series SM or DSM Sync Modules or PS -12/24-8 Power Supply). The Series SM and DSM Sync Module(s) shall incorporate two inputs from the Notification Appliance Circuits (NAC) for power connection from the Fire Alarm Control Panel; one for the strobe (NAC) circuit and one for the audible (NAC) circuit. A single 2 or 4 -wire output shall control both the audible and visual appliances. Upon activation of the audible silence function of the Fire Alarm Control Panel, the horn tone shall be silenced while maintaining strobe activation. Sound output at 10 feet shall be field selectable for 90 or 95 dBA anechoic at 24 VDC for both continuous or temporal (Code 3) tone. Series NS/NS4 shall provide listed strobe intensities of 15, 15/75, 30, 75, and 110 candela for wall mount applications, with a flash rate of one flash per second minimum across the listed voltage range. The strobe shall incorporate a Xenon® flashtube enclosed in a rugged Lexan° lens. Series SM or DSM Sync Modules or PS -12/24-8 Power Supply with Wheelocks Patented Sync Protocol and Series NS/NS4 Horn Strobes shall be designed as a system for continuous activation of the strobes. Should the Sync Module contacts fail in the passive state (i.e. contacts remain closed), the strobes shall revert to a non -synchronized rate of 1 flash per second (default mode). Series NS/NS4/NH appliances shall be designed for operation at 12 or 24 VDC, over their respective listed voltage ranges of 10.5 to 15.6 VDC; and 20.0 to 31.0 VDC. The units shall be designed for operation on filtered DC, or unfiltered VRMS. Rated average current for Series NS/NS4 shall depend upon voltage and strobe intensity; the Series NS current shall be as low as .065 amperes for 24 VDC versions and .137 amperes for 12 VDC versions and the Series NS4 current shall be as low as .053 amperes for 24 VDC versions and .133 amperes for 12 VDC versions (both with gain set at high dB output). Rated average current for Series NH (gain set at high dB output) shall be .021 amperes for 24 VDC versions and .014 amperes for 12 VDC versions. All versions shall be polarized for DC supervision and shall incorporate screw terminals for in/out field wiring of #18 to #12 AWG wire size. Series NS/NS4/NH shall incorporate a unique Universal Mounting Plate which shall allow mounting to single -gang, double -gang, 4" square, 100 mm European backboxes or Wheelock's SHBB surface backbox. No additional trim plate shall be required for flush mounting. If required an NATP (Notification Appliance Trim Plate) shall be provided. Dimensions for the Series NS/NS4/NH shall be 4.75 inches square by 1.22 inches deep. Due to continuous development of our product, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terms and conditions. NATIONAL SALES OFFICE 1-800-631-2148 Canada 800-397-5777 E-mail: Info@wheelockinc.com http://www.wheelockinc.com 3YEAR WARRANTY AP% J al riifflrmru Distributed By: WHEELOCK, INC. ■ 273 BRANCHPORT AVENUE ■ LONG BRANCH, N.J. 07740 ■ 732-222-6880 ■ FAX: 732-222-2588 S2100 Rev. 8/99 CtVDllru,, CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PQ,QTECTION 1 OFFICE OF THE STATE FIRE MARSHA. C F FIRE Ev4GINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:142 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchport Avenue, Long Branch, NJ 07740 Contact: Luy Nguyen (732) 222-6880 Fax (732) 222-8707 STA FIRE L Page 1 of 1 DESIGN: Model NH -12/24 horn and Models NS -1215W*, NS -121575W*, NS -2415W, NS -241575W, NS -2430W, NS -2475W and NS -241 10W; NS4-1215W *, NS4- 121575W*, NS4-2415W, NS4-241575W, NS4-2430W, NS4-2475W and NS4- 2411OW horn strobes. Model number may be followed by any two- alpha/numeric characters indicating lens, lettering and color. Units are synchronized or non -synchronized strobes. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical 10.5-31 VDC Candela 1 5 = 15cd, 1575 = 15/75cd on axis, 30 = 30cd, 75 = 75cd, 1 10=1 10cd (Wall) Flash rate 60 Flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Horn strobes are for wall mount only. MARKING: Listee's name, model number, electrical/candela rating and UL label. APPROVAL: Listed as audible and audible/visual signaling devices for use with separately listed electrically compatible fire alarm control units. Models with strobe lights are suitable for the hearing impaired. For indoor use only except for Model NH - 12/24 is suitable for outdoor. For synchronization strobes, Models SM -12/24, SMX-12/24, DSM -12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132) must be used. NOTE: These appliances can produce a distinctive three -pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1993 Edition. *Rev. 05-06-98 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. -)ate Issued: MAY 31, 2000 Authorized By. Effective issue date to expiration date LListing Expires June 30, 2001 BEN HO, Supervising Deputy Program Manager wheeJoex Lffg g INC. S5391 IVI EA 7125-0785:141 151-92-E Description E"11111111 N FIRE ALARM SYSTEMS Wheelock's patented Series RS Strobes and Series RSS Non- Sync/Sync Strobes have Lower Current Draw and the Series RSS has ZERO Inrush while maintaining their outstanding performance, reliability and cost-effectiveness in meeting or exceeding the latest requirements of NFPA 72 (National Fire Alarm Code -1999), ANSI 117.1 (American National Standard for Accessible and Usable Building and Facilities), and UL Standard 1971 (Signaling devices for the Hearing Impaired). RS/RSS Strobe Appliances, when properly specified and installed in accordance with NFPA/ANSI Standards, can provide the Equivalent Facilitation allowed under ADA Accessibility Guidelines (ADAAG General Section 2.2) by meeting or exceeding the illumination which results from ADA's strobe intensity guidelines of 75 candela at 50 feet. This is an illumination of 0.030 lumens per square foot. Wheelock's Series RS Strobes are available with 15 and 15/75 candela intensities for Wall mount only and non -sync applications. The Series RSS Strobes include Non -Sync and Sync in ONE appliance. The SM or DSM Sync Module or Wheelock's PS12/24- 8 Power Supply with Wheelock's Patented Sync Protocol must be used to achieve Sychronization of the strobe. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy. The strobe options for the Series RSS are 15, 15/75, 30, 75 and 110 candela intensities for Wall mount and 15, 30, 75 and 100 candela intensities for Ceiling mount applications. All strobes use a Xenon flashtube enclosed in a rugged Lexan® lens to provide maximum reliability for effective visual signaling. Wheelock's Series RS/RSS Strobes employ an integral Strobe Mounting Plate (patent pending) that makes it easy to mount to a variety of backboxes. The strobes can be mounted to single - gang, double -gang, 4" square, 100 mm European backboxes or the SHBG surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Trim Plate) may be used. It provides an additional .65" of trim for the appliance. An attractive cover plate is provided for a clean, finished appearance on all models. Since the inception of UL 1971 strobes cannot be Listed for outdoor use, Wheelock offers WM3T strobes for outdoor installations requiring weatherproof appliances and private mode operation where UL 1971 strobes are not required. They are UL 1638 Listed at 11 7c and are designed for surface mounting indoors or outdoors. "NOT TO BE USED AS AN INDOOR VISUAL EVACUATION SIGNAL OR FOR THE HEARING IMPAIRED." ONLY 88 MILLIAMPS 20-31 VDC WM3T — UL 1638 LISTED Copyright 1999 Wheelock, Inc. All rights reserved. SERIES RS STROBES AND SERIES RSS NON-SYNC/SYNC STROBES Series RS/RSS Series RS/RSS Strobe Mounting Plate Wall Cover Plate NATP Y Wall Strobe Features Series RS/RSS Strobes: • Approvals Include: Underwriters Laboratories UL 1971, FCC Part 15, European Community (CE), New York City (MEA), California State Fire Marshal (CSFM), and Factory Mutual (FM). Chicago (BFP). • ADA/NFPA/ANSI compliant. Meets OSHA 29, Part 1910.165. • LOW CURRENT. • Patented Strobe Mounting Plate for single gang, double gang, 4" square, or 100 mm European backboxes. Wheelock's SHBB shallow backbox is used for surface mounting. • Low current draw with temperature compensation to reduce power consumption and wiring costs. • Polarized 12 and 24 VDC models with wide listed voltage ranges using filtered DC or unfiltered VRMS input voltage. • Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires. Series RS: • 24 Volt only. • Wall mount only. • Available only in 15 and 15/75 candela intensity. • Non -Sync application only. Series RSS Strobes: • Both Non -Sync and Synchronized in ONE appliance. To achieve Synchronization a SM or DSM Sync Module or Wheelock's PS12/24-8 Power Supply with Wheelock's Patented -Sync Protocol must be used. • ZEROINRUSH. • 12 or 24 volt models. • Wall mount (RSS) available in 15, 15/75, 30, 75 and 110 candela intensity. • 15/75 candela low current draw wall mounted strobes are listed at 15 candela under UL 1971 and meet 75 candela intensity on axis for ADA guidelines. • Ceiling mount (RSS) available in 15, 30, 75 and 100 candela intensity. • Refer to Spec Sheet #S1100 for Series RSSP retrofit plates. I`� NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letter.. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum from 20-31 VDC (for 24 VDC models) or 10.5-15.6 VDC (for 12 VDC models). Note that NFPA-72 (1999) specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL 1971. • Series RS/RSS Strobe products are Listed under UL 1971 for indoor use with a temperature range of 32° F to 120° F (0° C to 49° C) and maximum humidity of 85%. • The VVM3T strobe is Listed under UL 1638 for outdoor use with a temperature range of -31'F to 150°F (-35°C to 66°C) maximum humidity of 95%. Specifications and Ordering Information Model Number* Order Code Input Voltage (VDC) Strobe Candela Average** Current (AMPS) @ 24 VDC Mounting Options*** WALL MOUNT STROBES - SERIES RS/RSS 0.043 0.052 0.066 0.108 0.131 RS -2415W -FR 7465 24 15 .050 B,D,E,FG,H,J,N,O,R,X RS -241575W -FR 7466 24 15/75 .065 B,D,E,FG,H,J,N,O,R,X 6374 12 - .020 W RSS-2415C RSS-2430C RSS-2475C RSS-24100C 20VDC RSS-2415W-FR 7470 24 15 .050 B,D,E,FG,H,J,N,O,R,X RSS-241575W-FR 7471 24 15/75 .065 B,D,E,FG,H,J,N,O,R,X RSS-2430W-FR 7472 24 30 .081 B,D,E,FG,H,J,N,O,R,X RSS-2475W-FR 7473 24 75 .133 B,D,E,FG,H,J,N,O,R,X RSS-24110W-FR 7474 24 110 .161 B,D,E,FG,H,J,N,O,R,X RSS-2415W-FW 7787 24 15 .050 B,D,E,FG,H,J,N,O,R,X RSS-241575W-FW 7788 24 15/75 .065 B,D,E,FG,H,J,N,O,R,X RSS-2430W-FW 7789 24 30 .081 B,D,E,FG,H,J,N,O,R,X RSS-2475W-FW 7790 24 75 .133 B,D,E,FG,H,J,N,O,R,X RSS-24110W-FW 7791 24 110 .161 B,D,E,FG,H,J,N,O,R,X RSS-1215W-FR 7475 12 15 .126 B,D,E,FG,H,J,N,O,R,X RSS-121575W-FR 7476 12 15/75 .161 B,D,E,FG,H,J,N,O,R,X RSS-1215W-FW 7467 12 15 .126 B, D, E, F, G,H,J,N,0,R,X RSS-121575W-FW 17468 1 12 1 15/75 1 .161 B, D, E, F, G,H,J,N,0,R,X CEILING MOUNT STROBES - SERIES RSS RSS-2415C-FW 7482 24 15 .067 B,D,E,FG,H,J,N,O,R,X RSS-2430C-FW 7483 24 30 .102 B,D,E,FG,H,J,N,O,R,X RSS-2475C-FW 7484 24 75 .204 B,D,E,FG,H,J,N,O,R,X RSS-2410OC-FW 7485 24 100 .238 B,D,E,FG,H,J,N,O,R,X SM Sync Module is rated for 3.0 amperes at 12 or 24 VDC; DSM Sync Module is rated for 3.0 amperes per circuit. The maximum number of interconnected DSM modules is twenty (20). (Refer to Data Sheet S3000 or installation instructions [P83123 for SM and P83177 for DSM].) Use with Series RSS appliances for synchronization or PS12/24-8 Power Supply. Series RS -Wall, RSS-Wall and RSS-Ceiling are available in either Red or White. Please contact Customer Service for order codes (if not stated above) and delivery information. Model Number* Order Code Input Voltage (VDC) Strobe Candela Average** Current (AMPS) @ 24 VDC Mounting Options*** SYNC MODULE 31VDC 0.043 0.052 0.066 0.108 0.131 SM -12/24-R 6369 12 - .014 W 0.148 0.189 12VDC 24 - .025 W DSM -1 2/24-R 6374 12 - .020 W RSS-2415C RSS-2430C RSS-2475C RSS-24100C 20VDC 24 - .038 W **AVERAGE CURRENT SERIES RSS WALL MOUNT APPLIANCES (24V) Voltage RSS-2415W RSS-241575W RSS-2430W RSS-2475W RSS-2411OW 20VDC 0.060 0.076 0.095 0.157 0.199 24VDC 0.050 0.065 0.081 0.133 0.161 31VDC 0.043 0.052 0.066 0.108 0.131 **AVERAGE CURRENT RSS WALL MOUNT APPLIANCES (12V) Voltage RSS-1215W RSS-121575W 10.5VDC 0.148 0.189 12VDC 0.126 0.161 15.6VDC 0.102 0.130 **AVERAGE CURRENT RSS CEILING MOUNT (24V) Voltage RSS-2415C RSS-2430C RSS-2475C RSS-24100C 20VDC 0.078 0.120 0.247 0.285 24VDC 0.067 0.102 0.204 0.238 31VDC 0.055 0.085 0.157 0.190 Model code suffix: W = wall or C = ceiling; F = fire lettering or call Customer Service if other lettering is required (Ex.: Feugo). R at end = red plate; W at end = white plate; Example: RSS-2415W-FR.*--RedRSS-2415W-FW --*-Whit, RSS2415C-FW�White Wall � Fire Wall "r' ire Ceilin-g'*' RFire Average current per actual Wheelock Production Testing @ 10.5, 12, 15.6, 20, 24 and 31 VDC. For rated average and peak current across the UL Listed voltage range for both filtered DC and full -wave rectified (FWR), see the installation instructions (P83500 for wall mount and P83501 for ceiling mount). *** Refer to Data Sheet S7000 for mounting options. 117 cd STROBE INDOOR OR OUTDOOR (must use WBB box for outdoor) Input Average Order Voltage Strobe Current Model Number Code (VDC) Candela (AMPS) Mounting Options WM3T-24-VFR 4911 24 117 .088 D,E,J,K Note: WM3T-24-VFR - UL 1638 only. Refer to installation instructions (P82037). SERIES RS and SERIES RSS QUICK REFL..cNCE GUIDE Model Number Wall Mount Ceiling Mount Non- Sync Sync's w/SM, DSM or PS12/24-8 Strobe Candela 24 VDC *Model #**Model Color 12 VDC RED # Color WHITE RS -2415W -FR X RESISTOR (EOLR) X i�� 15 X X RS -241575W -FR X X 15/75 X X RSS-2415W-FR X X X 15 X X RSS-241575W-FR X X X 15/75 X X RSS-243OW-FR X X X 30 X X RSS-2475W-FR X X X 75 X X RSS-2411 OW -FR X X X 110 X X RSS-1215W-FR X X X 15 X X RSS-121575W-FR X X X 15/75 X X RSS-2415C-FW X X X 15 X X RSS-243OC-FW X X X 30 X X RSS-2475C-FW X X X 75 X X RSS-24100-FW X X X 100 X X Model # Color is Red, can be ordered in White, see Specifications & Ordering Information for white order code. Model # Color is White, can be ordered in Red, call Customer Service for order code & Delivery. A WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" (P83500 FOR WALL MOUNT AND P83501 FOR CEILING MOUNT) AND "GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS DO UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: • TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. • FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. • COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. • THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED INPUT VOLTAGE RANGE. • INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. • INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. • USE STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBE ON CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBE MAY NOT FLASH. • FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. • CONDUCTOR SIZE (AWG), LENGTH AND CAPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wiring Diagrams* RSS APPLIANCE NON -SYNCHRONIZED RSS APPLIANCES SYNCHRONIZED WITH DSM MODULE DUAL CLASS "A" NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE AUDIBLE I NAC IIf�II�L CINCDIT OUT DSM e E -C + O -C - OUT I IN I + AUDIBLE AUDIBLE + OUT 2 + IN 2 p66 Q RSS Q P NINUE 2 RSS APPLIANCE wR�ENA6dR SYNCHRONIZED TO NEXT APPLI WITH SM 0 MODULE OR END -OF -LINE FROM PRECEDING L I I "B" NAC RESISTOR (EOLR) APPLIANCE OR FACP i�� AUDIBLE — SILENCE FEATURE 0 0- v,R RSS APPLIANCES SYNCHRONIZED WITH DSM MODULE DUAL CLASS "A" NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE AUDIBLE I NAC IIf�II�L CINCDIT OUT DSM e E -C + O -C - OUT I IN I + AUDIBLE AUDIBLE + OUT 2 + IN 2 p66 Q RSS Q P NINUE 2 RSS APPLIANCE wR�ENA6dR SYNCHRONIZED ---- 1 -WLdRWITH WITH SM 0 MODULE _ SINGLE CLASS 6IROBENC CIR, "B" NAC Len CIRCUIT WITH 0 AUDIBLE — SILENCE FEATURE 0 0- v,R RSS APPLIANCE wR�ENA6dR SYNCHRONIZED ---- 1 -WLdRWITH WITHMULTIPLE 0• DSM MODULE 0` GR 6IROBENC CIR, Len CISLF GR. dR. �+ SYXC INTERCONNECTING WIRING SHOWN. MAXIMUM OF TWENTY (20) For detail using SM or DSM Sync Module refer to Data Sheet S3000 or installation instructions (P83123 for SM and P83177 for DSM) * value determined by FACP NAC Circuit(s). #For wiring information on the PS -12/24-8 Power Supply refer to data sheet #S9001. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). ,t'►, ,-M, Architects and Engineers Specifications The visual notification appliances shall be Wheelock Series RS or RSS Strobe Appliances, or approved equals. Series RS/RSS shall meet and be Listed under UL Standard 1971 (Emergency Devices for the Hearing Impaired for indoor fire protection service). The strobes shall be listed for indoor use only. All strobes shall be certified to meet FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second minimum over the Listed Voltage range of 20 to 31 VDC for 24 volt models and 10.5 to 15.6 VDC for 12 volt models. All inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). All visual appliances shall incorporate a Xenon flashtube enclosed in a rugged Lexan lens. The Series RS and RSS Strobes shall be the Low Current Design and the RSS shall have Zero Inrush. The strobe intensity shall be rated per UL 1971 for 15, 15/75, 30, 75, and 110 candela for wall mount and 15, 30, 75 and 100 candela for ceiling mount applications for the Series RSS and 15 and 15/75 candela wall mount for Series RS public mode installations. The 15/75 candela strobe shall be specified when 15 candela UL 1971 listing with 75 candela intensity on -axis is required (e.g., ADA compliance). Series RSS appliances shall incorporate circuitry for synchronized strobe flash and shall be designed for compatibility with Wheelock Series SM and DSM Sync Modules and Wheelock's PS12/24-8 Power Supply. The strobes shall not drift out of synchronization at any time during operation. If the sync module fails to operate (i.e., contacts remain closed), the strobes shall revert to a non -synchronized flash rate. The visual appliances shall be designed for indoor surface or flush mounting. Series RS and RSS models shall employ a patent pending Strobe Mounting Plate that shall allow mounting to single -gang, double -gang, 4 inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required an NATP (Notification Appliance Trim Plate) shall be provided. An attaching cover plate shall be provided to give the appliance an attractive appearance. The aesthetic appearance shall not have any mounting holes or screw heads visible when the installation is completed. For outdoor installations, the strobe appliance shall be the Wheelock WM3T. The WM3T shall meet and be Listed under UL1638 (Private Mode Emergency and Utility Signaling). "NOT TO BE USED AS AN INDOOR VISUAL EVACUATION SIGNAL OR FOR THE HEARING IMPAIRED" The WM3T shall be mounted to a weather resistant backbox: either the Wheelock WBB box or approved equal when mounted outdoors. The WM3T strobes shall produce a flash rate of one (1) flash per second minimum over the Listed Voltage range of 20-31 VDC for 24 volt models. The strobe intensity shall be rated at 117 candela. Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terms and conditions. NATIONAL SALES OFFICE 1.800-631-2148 Canada 800-397-5777 E-mail: Info@wheelockinc.com http://www.wheelockinc.com 3 YEAR WARRANTY rvo== wilGH Distributed By: WHEELOCK, INC. ■ 273 BRANCHPORT AVENUE ■ LONG BRANCH, N.J. 07740 ■ 732-222-6880 ■ FAX: 732-222-2588 SO410 REV. 10/99 �CIWORIII� ..a,�, CALIFORNIA DEPARTMENT OF FORESTRY &FIRE PR::SECTION I�4 i_ OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE S -TA 111 -MM LISTING No. 7125-0785:141 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchport Avenue, Long Branch, NJ 07740 Contact: Luy Nguyen (732) 222-6880 Fax (732) 222-8707 DESIGN: Models RS -2415W, RS -241575W, RSP -2415W, RSP -241575W Strobe Light; Models RSS-2415W, RSS-2475W, RSS-241575W, RSS-2430W, RSS- 2411OW, RSSP-2415W, RSSP-2475W, RSSP-241575W, RSSP-2430W, RSSP-2411OW, RSS-1215W, RSSP-1215W, RSS-121575W, RSSP- 121575W, RSS-2415C, RSSP-2415C, RSS-2430C, RSSP-2430C, RSS- 2475C, RSSP-2475C, RSS-24100C, RSSP-24100C, *RSS-24MCW and *RSSP-24MC-W synchronized or non -synchronized Strobe Lights. Model number may be followed by any two alpha/numeric characters indicating lens orientation, lettering and color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical 20-31 VDC/FWR *RSS-24MCW, RSSP-24MCW: 16-33 VDC/FWR Candela 15 = 15cd, 1575 = 15/75cd on axis, 30 = 30cd, 75 = 75cd, 110 = 11 Ocd (Wall) *RSS-24MCW, RSSP-24MCW: Selectable 15cd, 30cd, 75cd or 1 10cd Flash rate 60 Flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Models with -W are intended for wall mount only. Models with -C are intended for ceiling mount only. MARKING: Listee's name, model number, electrical/candela rating and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only. For synchronization strobes, Models SM -12/24, SMX-12/24, DSM - 12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300- 0785:132.) must be used. *Rev. 06-05-2000 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an indeaendent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verifiy correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: J U N E 5, 2000 Authorized By.- Effective y.Effective issue date to expiration date Listing Expires June 30, 2001 'ZBEN HO, Supervising Deputy Program &Tanager wheeJoclk, u J MEA 7125-0785:143 E5946 151-92-E 7135-0785:109 Description 0"111111111 FLI° FIRE ALARM SYSTEMS Wheelock's Series CH Electronic Chimes minimize alarm system power supply and wiring costs with a low current draw of just 20 mA. These unique solid-state chime appliances provide field selectable single -stroke or vibrating operation with sound levels adjustable up to 83 dB and tone adjustable from 800 to 1200 Hz. They are available in two attractive package styles for flush mounting to standard electrical boxes or convenient surface mounting. The CH70 and CH90 models incorporate a patent pending chime mounting plate for faster, easier, level installation with a new aesthetic two (2) screw grille cover for a more pleasing appearance. Additionally, the Series CH70 Chime Strobe models incorporate the Lower Current, Zero Inrush Series RSS Non- Sync/Sync Strobes (synchronization of the strobe flash is achieved when used with Wheelock's SM or DSM sync modules. Series CH Chime Strobes are designed for maximum performance, reliability and cost-effectiveness while meeting or exceeding the latest visible signaling requirements of NFPA 72 (National Fire Alarm Code), ANSI 117.1 (American National Standard of Accessible and Usable Buildings and Facilities) and UL Standard 1971 (Standard for Signaling Devices for the Hearing Impaired). CH Chime Strobes, when properly specified and installed in accordance with NFPA/ANSI Standards, can provide the Equivalent Facilitation allowed under ADA Accessibility Guidelines (ADAAG General Section 2.2) by meeting or exceeding the illumination which results from the ADA specified strobe intensity of 75 candela at 50 feet. This is an illumination of 0.030 lumens per square foot. The Series CH Chime Strobes are UL Listed for indoor use, ceiling and wall mount, under Standard 1971 for Signaling Devices for the Hearing Impaired and under Standard 464 for Private Mode Audible Signal Appliances. They incorporate a Xenon flashtube with solid state circuitry enclosed in a rugged Lexan° lens to provide maximum reliability for effective visual signaling. Series CH Chimes are offered in 24 VDC models and are designed to operate over a wide voltage range with filtered DC or unfiltered VRMS input voltage. All models include IN/OUT wiring terminations that accept two #12 to #18 AWG wires at each terminal. Inputs are polarized for compatibility with standard reverse polarity type supervision. Features • Approvals include: UL 1971 and UL 464, FCC Part 15; Pending: FCC Part 15, California State Fire Marshal (CSFM), New York City (MEA), Chicago (BFP) on all models. • Strobes are designed to meet or exceed latest NFPA/ANSI Standards and ADA Accessibility Guidelines. Meets OSHA 29 Part 1910.165. • Unique electronic chime design provides superior quality, versatile performance and improved appearance with one- tenth the current draw of most electromechanical chimes. • Field selectable choice of single stroke or vibrating operation with volume control and tone control. • 3 year warranty. Copyright 1999 Wheelock, Inc. All rights reserved. SERIES CN CHIMES AND CHIME STROBES SERIES CH70 Chime SERIES CH70 Chime Strobe w/Cover Attached w/Cover Attached SERIES CH Chime Strobe SERIES CH70 Chime Mounting Plate Strobe Cover Plate • Low current draw with low temperature compensation to reduce power consumption and wiring costs. • CH70 Strobe models are available with 15, 15/75, 30, 75 and 110 candela (wall mount) ratings for operation from a single NAC circuit (in vibrating mode) or separate NAC circuits. • Low current draw, Zero Inrush, Non-Sync/Sync Strobe models are for wall mount only. Synchronization requires the SM or DSM module(s). • 24 VDC chime and chime strobe models with wide Listed voltage range, using filtered DC or unfiltered VRMS. • Polarized inputs for compatibility with standard reverse polarity type supervision of circuit wiring by the Fire Alarm Control Panel. • Low cost installation to standard electrical boxes. Attractive flush or surface mounting options. • No additional trimplate required for flush mounting. Fast installation with In/Out screw terminals using #12 to #18 AWG wiring. • The 15/75 candela wall mounted strobes are listed at 15 candela under UL Standard 1971 and meet 75 candela intensity on axis for ADA guidelines, with low current draw. ,^ �. NOTE: All CAUTIONS and WARNINGS are identified by , symbol A. All warnings are printed in bold capital tette, A WARNING: PLEASE READ THESE SPECIFICATIONS AND THE MOST CURRENT INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THE FOLLOWING INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum from 20-31 VDC. Note that NFPA-72 (1999) specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective strobe intensity based on UL 1971. • Series CH Strobe products are UL 1971 for indoor use with a temperature range of 32° F to 120° F (0° C to 49° C) and maximum humidity of 85%. • Series CH Chimes are listed under UL 464 for audible signal appliances. Specifications and Ordering Information CH Series Model* Code Order Code Strobe Candela Anechoic Peak dBA @ 10 Ft dBA at 10 Feet Reverberant Min Max Rated Average Current @ 24 VDC** Mounting*** Options 12 CH70-24-R 7825 --- 83 52 58 .020 L,O,Q,P,V Chimes CH90-24-W 7826 --- 83 52 58 .020 Q,V CH70-241575W-FR CH70-2415W-FR 7829 15 83 52 58 .070 L,Q Wall CH70-241575W-FR 7830 15/75 83 52 58 .085 L,Q Chime CH70-243OW-FR 7831 30 83 52 58 .101 L,Q Strobes CH70-2475W-FR 7832 75 83 52 58 .153 L,Q X CH70-2411 OW -FR 7833 110 83 52 58 .181 L,Q CH Series Model* Code Order Code Strobe Candela Anechoic Peak dBA @ 10 Ft dBA at 10 Feet Reverberant Rated Average Current @ 24 VDC** Mounting*** Options Min Max Ceiling Chime CH90-2475C-FW 8206 75 83 52 58 .223 ON Strobes CH90-2410OC-FW 8205 100 83 52 58 .236 Q,V Series CH70 and CH90 can be ordered in Red or White. Please contact Customer Service for order codes (if not stated above) and delivery information. " Average current per actual Wheelock Product Testing @ 24 VDC Nominal Voltage for Chime and Chime Strobe combined. For rated average, peak and inrush current across the listed voltage range for both filtered DC and unfiltered VRMS, see most current Installation Instructions (P83599). *** Refer to Data Sheet #S7000 for mounting options. Model code suffix W = wall mount, F = Fire lettering or call customer service if other lettering is required (Ex. Feugo) R = Red; W at end = White Example: CH70-2415W-FR CH90-24-W Square/Wall/ File \Red Ro Ind \ White Application 1. The chimes are factory set in single stroke (SS) mode. They can be changed to vibrating (VIB) mode with jumper on PC Board. SINGLE STROKE OPERATION: The minimum input pulse duration must be at least 160 ms "on" time and 160 ms `off" time. The chime will only operate once each time it is pulsed. This mode is recommended for coded systems. VIBRATING OPERATION: Continuous input voltage applied to the chime will activate the chime at one second intervals. 2. The volume and tone controls have been adjusted at the factory to insure maximum dBA output. However, once the mode is selected, the installer may want to fine tune the signal to better suit the application. 3. Anechoic dBA is measured in anechoic chamber with peak meter response. Reverberant dBA is rated per UL standard 464. 4. Chime inrush current is 0.100 amps maximum with filtered DC input (0.140 amps with VRMS input voltage) with a time duration of 100 milliseconds. Model Number Order Code Input Voltage (VDC) Avg. Current @ 12 or 24 VDC Mounting Options SYNCHRONIZATION MODULES SYNC MODULE SM -12/24-R 6369 12 .014 W 24 .025 W X DSM -1 2/24-R 6374 12 .020 W 24 .038 W SM Sync Modules are rated for 3.0 amperes at 12 or 24 VDC: DSM Dual Sync Modules are rated for 3.0 amperes per circuit. The maximum number of interconnected DSM modules is twenty (20). Refer to Data Sheet S3000 or Installation Instructions. Series CH Quick Reference Guide Model Number* WallCeiling Mount Mount Non- Sync Strobe Syncs, w/SM or DSM Strobe Candela CH70-24-R X X X CH90-24-W X X X CH70-2415W-FR X X X 15 CH70-241575W-FR X X X 15/75 CH70-243OW-FR X X X 30 CH70-2475W-FR X X X 75 CH70-2411 OW -FR X X X 110 CH90-2475C-FW X X X 75 CH90-2410OC-FW X I X X 100 CH70 and CH90 can be ordered in Rell or White.1 Call Customer Service for Order Code (if not stated above) and delivery information. ... .. A WARNING: CONTACT WHEELOCK FOR THE r CURRENT "INSTALLATION INSTRUCTIONS" (P83599); 'GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS DO UNurriGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAvt CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: • TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM PRIMARY AND SECONDARY POWER SOURCES. • FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE MAXIMUM INRUSH OR PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. • COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. • THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED INPUT VOLTAGE RANGE. • INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. • INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. • USE STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBE ON CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBE MAY NOT FLASH. • FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. • CONDUCTOR SIZE (AWG), LENGTH AND CAPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wiring Diagrams CH CHIME AND STROBE OPERATE INDEPENDENTLY (NON -SYNC OR SYNC) FROM TO NEXT CHIME OR PRECEDING ENO -OF -LINE RESISTOR CHIME (EOLR) OR FACP FROM PRECEDING - - - - - - - - - - r----- - TO NEXT STROBE APPLIANCE, - - - - - - - - - - OR EOLR SYNC MODULE OR FACP COM STROBE CHIME (OPTIONAL) CH STROBE APPLIANCE SYNCHRONIZED WITH MULTIPLE DSM MODULES CH = Senc� �, �� NTE CONNECTING WIRING SHOWN. MAXIMUM OF TWENTY (20) FACP OSM ft Refer to SM/DSM data sheet S3000 and installation instructions (P83123 for SM and P83177 for DSM). Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). � "Onk Architects and Engineers Spect—cations The chime appliances shall be a Wheelock Series CH audible or audible visual appliance or equivalent. Notification appliance shall be electronic and use solid state components. Electromechanical alternatives are not approved. Each electronic chime appliance shall provide field selectable single stroke or vibrating operation with volume control and tone control. The chime and the strobe shall be able to operate from a single NAC circuit when set to the vibrating mode. The peak anechoic dBA measurement at 10 feet shall be adjustable up to 83 dBA, at nominal voltage. Operating voltages shall be 24VDC for chimes and chime strobes using filtered power or unfiltered (VRMS) power supply. All models shall have provisions for standard reverse polarity type supervision and IN/OUT field wiring using terminals that accept #12 to #18 AWG wiring. Combination chime strobe appliances shall incorporate a Xenon flashtube enclosed in a rugged Lexan lens or equivalent with solid state circuitry that are Non -Sync or Sync in one (synchronization requires the SM or DSM Sync Module(s)). If the SM or DSM Sync Module(s) contacts fail in the passive state (i.e., contacts remain closed) the strobe shall revert to a non -synchronized flash rate of 1 flash per second. Strobe shall meet UL 1971 and produce a flash rate of one (1) flash per second minimum over the Listed input voltage (20VDC-31 VDC) range. The strobe intensity shall be rated per UL 1971 for 15, 15/75, 30, 75 or 110 candela for wall mount and/or 75 and 100 candela for ceiling mount. The 15/75 candela wall mount strobe shall be specified when 15 candela UL 1971 Listing with 75 candela intensity on axis is required. All UL 1971 Listed strobe appliances shall be verified to meet FCC Part 15, Class B and incorporate low temperature compensation to insure the lowest possible current consumption. Strobe activation shall be via independent input or from the same input circuit as the chime. The combination chime strobe appliances may be installed indoors and surface or flush mounted. The chime and chime strobes shall incorporate a chime mounting plate with a grille cover which is secured with two screws for a level esthetic finish. They shall mount to standard electrical hardware requiring no additional trimplate or adapter. The appliance shall be finished in a textured red or white color. NATIONAL SALES OFFICE 1-800-631-2148 Canada 800.397-5777 E-mail: Info@wheelockinc.com http://www.wheelockinc.com 3 YEAR WARRANTY r% ME-SWw Distributed By: WHEELOCK, INC. ■ 273 BRANCHPORT AVENUE ■ LONG BRANCH, N.J. 07740 ■ 732-222-6880. FAX: 732-222-2588 S0710 Rev. 4/99 e�.�,�, CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I*nR-EM ,� ' OFFICE OF THE STATE FIRE MARSHAL C FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM F L LISTING SERVICE LISTING No. 7125-0785:143 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchport Avenue, Long Branch, NJ 07740 Contact: Luy Nguyen (732) 222-6880 Fax (732) 222-8707 DESIGN: Sync or CH70-2415W,-241575W,-2430W,-2475W, -2411 OW Non Sync CH90-2415W,-241575W,-2430W, -2475W, -2411 OW Chime Strobes CH70-2415C,-2430C,-2475C,-24100C CH90-2415C,-2430C,-2475C,-24100C Units may be followed by suffixes to designate lens orientation, lens lettering and plate color. Models with suffix —W are wall mount and —C are for ceiling. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 24 (20-31 VDC) Flash rate: 60 flashes/min Candela: 15: 15cd, 1575: 1 5cd/75cd on axis, 30: 30cd, 75: 75cd 100: 1 00c (ceiling mount only), 110: 11 Ocd (wall mount only) INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating and UL label. APPROVAL: Listed as chime strobes suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only. For synchronized strobes, Models SM -12/24, SMX-12/24, DSM -12/24 or DSMX-12/24 sync module must be used. If this appliance is required to produce a distinctive three -pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1996 Edition, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. 01-21-98 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date issued: MAY 31, 2000 Authorized By: Effective issue date to expiration date Listing Expires June 30, 2001 BEN HO, Supervising Deputy Program Manager Din T BELLS ER PBA ' C f B Potter Electric Signal Company Potter Electric Signal & Mfg., LTD. 2081 Craig Road • P.O. Box 28480 55 Glen Cameron Road St. Louis, MO 63146-4161 Thornhill, Ontario, Canada L3T 1P2 (314) 878-4321 • (800) 325-3936 (905) 882-1833 UL LISTED, FM APPROVED Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC 120VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling BurglarAlarm Environment: Indoor or outdoor use (See Note 1) -40° to 150°F (-40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination: 4 No. 18 AWG stranded wires 6" BELL SHOWN Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (101 mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. ALL DC BELLS ARE POLARIZED AND HAVE BUILT-IN TRANSIENT PROTECTION: SIZE INCHES (mm) VOLTAGE MODEL NO. STOCK NO. CURRENT (MAX) TYPICAL dB AT 10 FT. (3m) (2) MINIMUM dB AT 10 FT. (3m) (1) 6 (150) 12VDC PBD126 1706012 .12A 65 76 8 (200) 12VDC PBD128 1708012 .12A 90 76 10(250) 12VDC PBD1210 1710012 .12A 92 76 6 (150) 24VDC PBD246 1706024 .06A 87 76 8 (200) 24VDC PBD248 1708024 .06A 91 79 10 (250) 24VDC PBD2410 1710024 .06A 94 79 6(150) 24VAC PBA246 1806024 .17A 91 76 8(200) 24VAC PBA248 1808024 .17A 94 76 10 (250) 24VAC PBA2410 1810024 .17A 94 76 6 (150) 120VAC PBA1206 1806120 .05A 92 82 8(200) 120VAC PBA1208 1808120 .05A 99 82 10(250) 120VAC PBA12010 1810120 .05A 99 85 Notes: 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laborato- ries as specified in UL Standard 464. UL temperature range is -30° to 150°F (-34° to 66°C). 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. PRINTED IN USA MKT. #8850001 . REV N PAGE 1 OF 2 MFG. #5400776 - 11195 FIG.1 BELLS 10� (250) r — L l —, (200) 6" (150) I I I I L_�7_J --�-I 2 11/16- I (68) DWC. /776-1 FIG. 2 WEATHERPROOF BACKBOX BOX HAS ONE THREADED 1/2" CONDUIT ENTRANCE 5 3/4" O (146) �15/8-- (41) /8-_(41) DWG. /776-2 3 3/8- q1 (86) 4 1/4- (108) FIG. 3 WIRING (REAR VIEW) D.C. BELLS (OBSERVE POLARITY) A.C. BELLS RED (IN) RED (OUT) WHI](IN) (OUT) O KWHITE FROM CONTROL PANEL TO NEXT BELL FROM CONTROL PANEL OR OR END—OF—UNE OR PRECEDING BELL RESISTOR PRECEDING BELL BLACK (IN) o BLACK (OUT) BLABLACK (OUT) CAUTION: WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: 1. OBSERVE POLARITY TO RING D.C. BELLS. 2. RED WIRES POSITIVE (+) 3. BLACK WIRES NEGATIVE (—) DWG. #776-3 INSTALLATION CAUTION: WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. 5' (127) NOTES: 1. WHEN USING A.C. BELLS, TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL- 2. ELL2. END—OF—UNE RESISTOR IS NOT REQUIRED ON A.C. BELLS. 1. The bell should be mounted a minimum of 8 ft. (2.4m) from the floor or as close to the ceiling as possible. 2. Remove the gong. 3. Connect wiring (see Fig. 3). 4. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 5. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 6. Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). PRINTED IN USA MKT. #8850001 - REV N PAGE 2 OF 2 MFG. #5400776 - 11195 g�F CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTIONOFFICE OF THE STATE FIRE MARSHAL FIRE ANEERING - BUILDING MATERIALS LISTING PROS.., -%M STA'fg F11fE MA�iAI LISTING SERVICE LISTING No 7135-0328:119 Page of 1 CATEGORY Audible Device LISTEE Potter, 2081 Craig Road, St. Louis MO 63146 Contact: Matthew Springli (800) 325-3936 DESIGN. Models PBD126, PBD128, PBD1210, PBD246, PBD248, PBD2410, PBA246 PBA248, PBA2410, PBA1206, PBA1208 and PBA12010 vibrating bells. Suitable for outdoor use when used with Model BBK-1 backbox. Models are AC or DC powered and available in 6", 8" and 10". Refer to listee's data sheet for detailed product description and operational considerations. RATING: PBD -126, -128, -1210: 12 VDC PBD -246, -248, -2410: 24 VDC' PBA -246, -248, -2410: 24 VAC PBA -1206, -1208, -12010 120 VAC INSTALLATION In accordance with listee's printed installation instruction, applicable codes & ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING Listee's name, model number and UL label. APPROVAL Listed as audible devices for use with separately listed compatible fire alarm control units. `If this appliance is required to produce a distinctive three - pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1993 Edition, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. 'Rev. 03-16-98 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results a and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or �} recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation t criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: J U N E 5, 2000 Authorized By.- Effective y.Effective issue date to expiration date 6�jk-- IF Usti ng Expires June 30, 2001 BEN HID, Supervising Deputy Program Manager FIRE EI JEERING -BUILDING MATERIALS LISTING PRO% -_AM V LISTING SERVICE 5T"FIREN,"W` LISTING No. 7300-0569:124 Page 1 of 1 CATEGORY: Misc. Device/Control Unit Accessories LISTEE: Gentex Corporation, 10985 Chicago Dr., Zeeland MI 49464 Contact: Lisa Lantz (616) 392-7195 DESIGN: Model WGBB back box. Intended for use with listee's separately listed audible and visual appliances. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as *weather proof back box for use with separately listed audible and visual appliances. 'Corrected 11-30-98 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 22, 2000 Effective issue date to expiration date 11 Listing Expires June 30, 2001 11 Authorized By: BEN %HO, Supervising Deputy Program Manager CSFM: 7125-0785:122 Description ■■■111111111H�l FIRE ALARM SYSTEMS SERIES MT and MT STROBE and SYNCHRONIZED MULTITONE ELECTRONIC SIGNALS Wheelock's Series MT and MT Strobe Multitone electronic signals offer a choice of eight (8) nationally and internationally recognized alerting sounds: Horn, Bell, March Time Horn, Code -3 Tone, Code -3 Horn, Slow Whoop, Siren or Hi/Lo Tone. Our Code -3 horn and tone patterns are engineered to comply with NFPA/ANSI Temporal Pattern specifications without requiring additional equipment. With MT and MT Strobe Signals, one alarm appliance meets most of your signaling needs. Synchronized strobe versions are available. The MT Strobes are designed for ADA applications with maximum performance, reliability and cost-effectiveness while meeting or exceeding the latest requirements of NFPA 72 (the National Fire Alarm Code), ANSI 117.1 (the American National Standard For Accessible and Usable Buildings and Facilities) and UL Standard 1971 (Standard for Signaling Devices for the Hearing Impaired). MT strobes, when properly specified and installed in accordance with NFPA/ANSI Standards, can provide the Equivalent Facilitation allowed under ADAAccessibility Guidelines (ADAAG General Section 2.2) by meeting or exceeding the illumination which results from the ADA specified strobe intensity of 75 candela at 50 feet. This is an illumination of 0.030 lumens per square foot (footcandles). Each MT and MT Strobe appliance has two user selective sound output levels: STANDARD dBA and HIGH dBA. Non -strobe versions provide selectable voltage capability in one unit, 12VDC or 24VDC, filtered or FWR. Strobe versions are specific for either 12VDC or 24VDC and may be used with filtered or unfiltered (full -wave -rectified) input voltages. Separate input terminals are available, shunt wires are provided to enable both tone and strobe to operate simultaneously from a single input. The Multitone Strobe Signals are UL Listed for indoor use, ceiling and wall mount, under Standard 1971 for Signaling Devices for the Hearing Impaired and Standard 464 for Audible Signal Appliances, and use a Xenon flashtube with solid state circuitry enclosed in a rugged Lexan® lens to provide maximum reliability for effective visible signaling. Options include LS, MS and IS Series which are Listed at 15, 30 and 75 candela intensity to cover 20'X 20', 30'X 30' and 40'X 40' rooms, respectively. THE LSM SERIES 15/75 CANDELA WALL MOUNTED STROBES WERE TESTED AT UL FOR 75CD ON AXIS, AND ARE LISTED AT 15 CANDELA UNDER UL 1971 AND MEET 75 CANDELA INTENSITY ON AXIS FOR ADA GUIDELINES WITH LOW CURRENT DRAW. SERIES MT SERIES MT WITH 1013 Copyright 1996 Wheelock, Inc. All rights reserved. SERIES MT Features • Approvals include: Underwriters Laboratories (UL 1971 and UL 464) Listings, Factory Mutual, California State Fire Marshal, New York City MEA and Chicago BFP, OSHA 29 Part 1910 approvals on all models. • MT & MT-WM Strobe model available for outdoor installation requiring weatherproof devices. In private mode location where UL 1971 strobes are not required the MT-WM strobe model is UL 1638 Listed at 117 cd and is designed for mounting indoors or outdoors. • Series MT Signals have IN and OUT wiring terminations that accept two #12 to #18 American Wire Gauge (AWG) wires at each terminal. Inputs are polarized for compatibility with standard reverse polarity type supervision. • One alarm appliance with (8) eight selective signals to provide superior sound penetration for various ambient and wall conditions with two field selectable sound output levels. • Code -3 Horn and Tone meet ANSI/NFPA/ISO temporal pattern for standard emergency evacuation signaling. • Audible and strobe can operate from a single signaling circuit with any of the (8) eight audible signals. • Designed to meet or exceed NFPA/ANSI Standards and ADA Accessibility Guidelines. • Low current draw with low temperature compensation to reduce power consumption and wiring costs. • MT Strobe models available with 15, 15/75, 30 and 75 candela ratings for independent or single input activations and synchronized strobe design. • Wheelock's patented LS, LSM, MS, IS, HSW and synchronized Series strobe designs offer fire alarm system designers, specifiers and installers the industry's widest selection of UL 1971 Listed strobe products. • Series MT Strobe multitone electronic signals equipped with SUSLM synchronized strobes, when used in conjunction with Wheelock SM/DSM sync modules, produce a synchronized strobe flash for compliance with ADA guidelines concerning photosensitive epilepsy. • 12VDC and 24VDC models with wide -Listed voltage range, filtered (DC) and FWR. • Selectable input voltage on non -strobe versions. Strobe versions are factory set for either 12 or 24VDC. • Series MT Signals have IN and OUT wiring terminations that accept two #12 to #18 American Wire Gauge (AWG) wires at each terminal. Inputs are polarized for compatibility with standard reverse polarity type supervision. • Mounts to either 4" square or double gang switch boxes (important for retrofit installations). Attractive flush or surface mounting. • No additional trimplate required for flush mounting. • Compliance with RFI limits in FCC Part 15, Class B for compatibility with sensitive detection and communication circuits. A WARNING: PLEASE READ THESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION ANDIOR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Alarm Tares NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. TONE ALARM TONES PATTERN DESCRIPTION HORN BROADBAND HORN (Continuous) BELL 1560 Hz MODULATED (0.07 sec. ON/Repeat) MARCH TIME HORN HORN (0.25 sec. ON/0.25 sec. OFF/Repeat) CODE -3 HORN HORN (ANSI S3.41 Temporal Pattern) CODE -3 TONE 500 Hz (ANSI S3.41 Temporal Pattern) SLOW WHOOP 500-1200 Hz SWEEP (4.0 sec. ON/0.5 sec. OFF/Repeat SIREN 600-1200 Hz SWEEP (1.0 sec.ON/Re eat) HI/LO 1000/800 Hz 0.25 sec. ON/Alternate General Notes: • Strobes are designed to flash at 1 flash per second minimum from 20-31VDC (for 24VDC models) or 12-15.60C (for 12VDC models). Note that ADA guidelines presently specify a flash rate of 1 to 2 flashes per second. • All candela ratings represent minimum effective Multitone Strobe intensity based on UL 1971. • MT Strobe models are UL 1971 Listed for indoor use with a temperature range of 32*F to 120°F (0°C to 49°C) and maximum humidity of 85%. All MT and MT4 with WM or WH strobe models for outdoor use are Listed for -31 OF to 150°F (-35 C to 66°C) and maximum humidity of 95%. Specifications 'i. Hnecnoic am is measurea on axis in a non-reriective twee Held) test room using fast meter response. For peak dBA (measured with peak meter response), add 5 dBA to typical anechoic values shown in Table 1 and 2. 2 Reverberant dBA is a minimum UL rating based on sound power measurements in a reverberant test room. *A CAUTION: This setting is acceptable only for general signaling (non -fire alarm) use. Use the "high" dBA setting with this tone or use a different tone for public mode fire alarm service. Table 2: dBA and Current Ratings for Audible Portion of Multitone Signals With Strobes Table 1: dBA and Current Ratings for Multitone Signals Without Strobes Tone In ut Current AMPS @ 24VDC Tone Input Current AMPS 0 24VDC Input Current AMPS C 12VDC Typical Anechoic' dBA at 10 Feet At Nominal Input Volta a Rated Reverberant dBAz at 10 Feet Per UL 464 At Minimum At Nominal Input Volta a Input Volta e H1 STD HI STD HI STD HI STD HI STD F10.023 Horn 0.040 0.020 0.010 0.100 0.020 101 95 88 82 91 85 Bell 0.014 0.012 0.031 0.010 94 89 82 75 85 79 March Time Horn 0.040 0.023 0.100 0.020 101 95 85 79 88 82 Code -3 Horn 0.040 0.023 0.100 0.020 101 95 85 75 85 79 Code -3 Tone 0.028 0.017 0.060 0.015 97 92 79 75 82 75 Slow Whoop 0.048 0.026 0.100 0.025 101 96 88 82 88 82 Siren 0.036 0.023 0.082 0.020 100 95 85 82 88 82 H 1/L0 0.020 0.014 0.044 0.012 95 90 82 79 85 79 'i. Hnecnoic am is measurea on axis in a non-reriective twee Held) test room using fast meter response. For peak dBA (measured with peak meter response), add 5 dBA to typical anechoic values shown in Table 1 and 2. 2 Reverberant dBA is a minimum UL rating based on sound power measurements in a reverberant test room. *A CAUTION: This setting is acceptable only for general signaling (non -fire alarm) use. Use the "high" dBA setting with this tone or use a different tone for public mode fire alarm service. Table 2: dBA and Current Ratings for Audible Portion of Multitone Signals With Strobes Tone In ut Current AMPS @ 24VDC In ut Current AMPS 012VDC Typical Anechoic' dBA at 10 Feet At Nominal Input Volta a Rated Reverberant dBW at 10 Feet Per UL 464 At Minimum At Nominal Input Volta a Input Volta e HI STD HI STD HI STD HI STD HI STD Horn Bell 0.040 0.014 0.023 0.012 0.100 0.031 0.020 0.010 99 93 92 87 85 79 79 75 88 82 82 75 March Time Horn 0.040 0.023 0.100 0.020 99 93 82 75 85 79 Code -3 Horn 0.040 0.023 0.100 0.020 99 93 79 75 82 75 Code -3 Tone 0.028 0.017 0.060 0.015 95 90 75 70 * 79 73 Slow Whdop Siren 0.048 0.036 0.026 0.023 0.100 0.082 0.025 0.020 99 94 98 93 82 82 75 75 85 85 79 79 H1/L0 0.020 0.014 0.044 0.012 93 88 79 75 82 1 75 'i. Hnecnoic am is measurea on axis in a non-reriective twee Held) test room using fast meter response. For peak dBA (measured with peak meter response), add 5 dBA to typical anechoic values shown in Table 1 and 2. 2 Reverberant dBA is a minimum UL rating based on sound power measurements in a reverberant test room. *A CAUTION: This setting is acceptable only for general signaling (non -fire alarm) use. Use the "high" dBA setting with this tone or use a different tone for public mode fire alarm service. Wiring Diagrams (for all models) MT Signal Audible signal and strobe operate independently Audible signal and strobe operate in unison. Red and RATED CANDELA AVERAGE* STROBE CURRENT (AMPS) black shunt -wires are supplied. FFN + + TO FM0110 oa)iu FR4MFRGMK4 + 16 roer uaaF uA4Upi OR FROM PFF&E13PM. $+- + $Tcr}N,i M*R 86MLO1D 9t1 OR --- ---- FRMFRMNQ+ +1619XT + — *Moa OR f"ok +T �- 4NKU Fi". — — IAM $TFXM AUDIBLE --- +— + 4ToriCi All W K,N,O,T,U Ordering Information MODEL NUMBER ORDER CODE INPUT VOLTAGE RATED CANDELA AVERAGE* STROBE CURRENT (AMPS) MOUNTING** OPTIONS MT -12/24-R 5023 12/24 --- ---- E,FL,M,O,T,U MT4-12/24-R 5308 12/24 --- ---- K,N,O,T,U MT4-115-R 6223 115 VAC --- ---- K,N,O,T,U MT-24-LS-VFR 5183 24 15 .074 E,FL,M,O MT-24-SL-VFR 6306 24 15 .096 E,F,LM,O MT-24-LSM-VFR 5182 24 15/75 .100 E,FL,M,O MT-24-SLM-VFR 6307 24 15/75 .138 E,FL,M,O MT-24-MS-VFR 5321 24 30 .124 E,FL,M,O MT-24-IS-VFR 5355 24 75 .200 E,FL,M,O MT4-115-WH-VFR *** 6224 115 VAC 15 .060 K,N,O MT-24-WM-VFR *** 5025 24 117 .088 E,FL,M,O MT-12-LS-VFR 5383 12 15 .155 E,FL,M,O MT-12-MS-VFR 5384 12 30 .227 E,FL,M,O MT-12-LSM-VFR 5683 12 15/75 .210 E,FL,M,O SM SYNC MODULE**** SM -12/24-R 6369 12 or 24 .014/.025 E,N DSM SYNC MODULE**** DSM -12/24-R 6374 12 or 24 .020/.038 W NOTE: If the strobe and audible operate on the same circuit, add the strobe current from above The letters SL and SLM denote synchronized models. to the proper current from Table 2. Average current per actual Wheelock Production testing at 12 & 24VDC nominal voltage. For rated average, peak and inrush currents across the listed voltage ranges for both filtered DC and full waved rectified (FWR), see the Installation Instruction for this product series or Wheelock's current "Alarm Signals" catalog. " For additional information, please refer to Data Sheet #57000 for mounting options. Listed for UL 1638 only. SM Sync Modules are rated for 3.0 amperes at 12/24 VDC; DSM Dual Circuit Modules are rated for 3.0 amperes per circuit. The maximum number of interconnected DSM modules is twenty (20). Refer to Data Sheet #S3000. MT & MT4 models can be used win Wheelock's model RSP-24110-HFR strobelplate assembly for 110 candela strobe signals. Refer to Spec. Sheet 55000 for MT4. Suffix: V = vertical lens; H = horizontal lens; F = fire lettering; R = red plate. A WARNING: CONTACT WHEELOCK FOR "INSTALLATION INSTRUCTIONS" AND "GENERAL INFORMATION" SHEET ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: • TOTAL CURRENT REQUIRED BY ALL DEVICES CONNECTED TO SYSTEM PRIMARY AND SECONDARY POWER SOURCES. • FUSE RATINGS ON SIGNALING CIRCUITS TO HANDLE MAXIMUM INRUSH OR PEAK CURRENTS FROM ALL DEVICES ON THOSE CIRCUITS. THE TIME DURATION OF THE MAXIMUM STROBE INRUSH OR PEAK CURRENT IS 2 MILLISECONDS FOR LS/LSM/MS MODELS AND 4 MILLISECONDS FOR IS MODELS. • COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. • THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED INPUT VOLTAGE RANGE. • INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. • INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. • USE STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBE ON CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBE MAY NOT FLASH. • FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be erformed by qualified personnel for Proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). CPl1FOPMy d�f�cw[rPartc�"� c l D QiM F LISTING No. CATEGORY: LISTEE: DESIGN: CALIF RNIA DEPARTMENT OF FORESTRY & FIRE P."OTECTION OFFICE OF THE STATE FIRE MARSHA, FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7125-0785:122 Fire Alarm Devices for the Hearing Impaired Wheelock Inc., 273 Branchport Avenue, Long Branch, NJ 07740 Contact: Luy Nguyen (732) 222-6880 Fax (732) 222-8707 Page 1 of 1 Model MT and MT4 Series Multitone Strobe Horns with the following suffixes: 12 (10.5-15.6 VDC) or 24 (20-31 VDC) No suffix (60 flashes/min) or L (20 flashes/min) LS or SL (15cd), LSM or SLM (15cd/75cd), MS (30cd), IS (75cd), HSPW or SHPW (1 1 Ocd) Units may follow by suffixes to designate orientation, lettering and plate color. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models using LSM, SLM, SHPW or HSPW strobes are for wall mount only. Other units are suitable for wall or ceiling mount. MARKING: Listee's name, model number, electrical/candela rating and UL label. APPROVAL: Listed as horn/multi-tone horn strobes devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only. Model with suffix SL, SLM or SHPW employs a synchronized strobe and must be used with Model SCM -24 sync control module. *These appliances can produce a distinctive three pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1993 Edition. *Corrected 01-19-99 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 31, 2000 Authorized By: Effective issue date to expiration date Listing Expires June 30, 2001 BEN HO, Supervising Deputy Program Manager 0 Heat Detectors Series 600 The Heat Detectors Series 600 are supplied with the following standard features: • Rate -of -Rise and Fixed Temperature " Low Profile • One or Two -Circuit, Normally Open • Visual Indication • Easy Installation • Operation Testing The Series 600 Heat Detector is attractive, durable and features combination rate -of -rise and fixed temperature operation. Heat detectors are available in 135•F and 200•17 temperature ratings. Rate -of -rise detects heat by quickly responding to a rapid temperature increase. Rate -of --rise units have a wide spacing allowance of 50 -foot centers. See specification table for details. Fixed temperature reacts to heat by responding to a specific temperature setting. Series 600 Detectors use the same reliable pneumatic rate -of - rise element of former models, but offer added aesthetic appeal. The pneumatic rate -of -rise element responds to a rapid rise in temperature, approximately 15•17. (8•C) per minute, by expansion of air within the sealed chamber faster than it can escape through a calibrated vent. The resultant increase in pressure depresses the diaphragm, causing the electrical contact to close the circuit. The fixed temperature element uses a fusible alloy. When activated, the external heat collector drops away to provide quick visual confirmation that the element has operated. The units protrude only 1-3/8 inch from the ceiling surface with a junction box mounting. They have pleasing contours and an all -white finish that conforms to ceiling aesthetics. Installation Each detector includes a patented reversible mounting plate In one position, it easily attaches to 4" square junction box, 3.25" or 4" octagonal box, or plaster ring. In reverse, the plate can be used for open wiring without a junction box. A 1/4" space between detector and mounting surface allows for wire connections. All mounting screws are concealed. The detector attaches easily to the mounting plate with a push and twist motion. No tools are required. All rights reserved (10199). Junction Box Mounting Ceiling Surface Mounting 1'318 2-1/8, 1-4-9/16, 3-1/4" or 4" Cut for surface Reversible Octagonal Box or mounting Mounting 4" Square Box Plate O Reversible Mounting O Plate 8 32" 6-32" Round Flat Head Head Screws wood 0 518 to t" o screws Mounting plate is molded of white self -extinguishing thermo- plastic rated at 221 •F (105.13). The plate is extremely strong yet adapts to uneven mounting surfaces. Series 600 Testing Methods Models 601/621 and 602/622 can be tested by the quick application of heat from any convenient source. A portable hair dryer is recommended. However, do not apply heat that exceeds the fixed temperature rating of the detector. Models 603/623 and 604/624 cannot be tested. However, the fusible alloy element used is considered so reliable that testing is not necessary. Model 601 and 621 Model 1602 and 622 Model 603 and 623 Model 604 and 624 No Marking Gray Ring Gray Spot 0 Gray Ring and Dot O Model 601 (1 circuit) O Model 602 (1 circuit) 0 Model 603 (1 circuit) Model 604 (1 circuit) O Model 621 (dua circuit) Model 622 (dual circuit) Model 623 (dual circuit) Model 624 (dual circuit) Rate -of -Rise and Fixed Rate -of -Rise and Fixed Fixed Temperature only, Fixed Temperature only, Temperature, 135•F (57•C) Temperature, 200•F (94•C) 135•F (57•C) 200•F (94•C) Applications: Normal Applications: Normal tempe- Applications: Unusually violent Applications: Unusually violent temperature fluctuations rature fluctuations and ceiling temperature fluctuations temperature fluctuations and and ceiling temperatures temperatures exceeding 100•F and ceiling temperatures ceiling temperatures exceeding not exceeding 100•F (38°C) (38•C) but not 150•F (66•C) not exceeding 100•F (381C) 100•F (38•C) but not 150•F (66•C) Maximum Spacing Maximum Spacing Maximum Spacing Maximum Spacing Allowance' - Allowance` - Allowance` - Allowance' - 50x50ft. -UL 50x50 ft. - UL 25x25 ft. - UL 15x15ft. -UL 30x30 ft. - FM 30x30 ft. - FM 20 x20 ft. - FM Refer to National Fire Alarm Code Standard WPA 72 for application requirements Screw Terminals Standard Single Circuit Detector Wire from alarm panel or previous detector. � Wire connected to next detector or end of line resistor. NOTE: All single circuit models come with one (1) normally open dry contact. Dual Circuit Detector Used to send two Independent signals. Wire connected to next detector or— end of line resistor. Kr1re from alarm panel or previous detector. Wire connected to next detector or end of line resistor. NOTE: All dual circuit models come with one (2) normally open dry contacts. Important Special Notes Application: Heat detectors should be used for property protection. Reliance should not be placed on heat detectors for Life Safety. CAUTION: When life safety is involved, smoke detectors MUST also be used. Detectors must not be painted. Battery Back -Up: Heat detectors should be electronically supervised with battery back-up at the panel. The rate -of -rise mechanism may be subject to reduced sensitivity over time. Annual testing of the rate -of -rise mecha- nism is recommended. Electrical Ratings 6-125 Volts A.C., 3.0 Amps. 6-28 Volts D.C., 1.0 Amps. 125 Volts D.C., 0.3 Amps. 250 Volts D.C., 0.1 Amps. Listings/Approvals • Listed by Underwriters Laboratories (UL) • Factory Mutual Approved (FM) • California State Fire Marshal Approval (CSFM) • City of New York (MEA) Listing No. 188-94-E • Listed by Underwriters' Laboratories of Canada (ULC) This literature is provided for informational purposes only. CHEMETRONICS assumes no responsibility for the product's suitability for a particular application. The product must be properly appppl1ied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact CHEMETRONICS, Ashland, MA; Telephone (800) 496-8383. Chemetronics 400 Main Street Ashland, MA 01721 USA Phone: (800) 496-8383 Fax: (800) 496-7272 Website: www.chemetronics.com All rights reserved (10/99). .r ISTf.Gi Chertlatron 4801. Sout(1vA q(re Ficor, Matteson, iL :8r3 Contact Gary Kirnb(s i��I ��� a�7 w3, 60.4. 021, -0.224 020 *.(, 0 ' . Ott t1�Cact to fit iGt GSite's duty atkieat 1ot.detai(etl product arlEyi%ixr.o4'ota 1"!fit t�11` i[1,+liCCOt'dai�rie;!IAti� �ist!!`5 iftKitCd:irt�taiiati4A I�tSici[ottpr�,;sC;abl� tsgd�s i��f•: 'M #i,ttipttnitr aiiib4e iibf�[isiefl7ri. AAi liV a L[32ea°8 Mole. model number, tomPerature rating and UL Mbef. APPROVAL, LigtOd as Not detr+tttbrs for use vAth Uparetely HMO Compatible fire alarm contfol units. tig0WOO* �gn n�r:i andtvF t acres: Visit t», ' r".ecrxnrrrnt�on�itthtz.G�tecC: trde .. f # li£�it3if 6h'di PlAe issupd j V IV t j .►aiw YON Live #%Nt+h (Ulf, ki pit Iffation ftit(� 1� tasting ExPires June. 3Q, 2001 Au(honted By BEN HQ. Spofvisirag m)pttly Pfogrool Manager Models Available Standard Application Models 2100S 2100TS 2112/24S 2112/24TS Auxiliary Form C Relay Models 2100TR 2112/24R 2112/24TR Temporal Pattern Sounder Models 2100AT 2112/24AT 2112/24ATR 2112/24AITR Product Overview Full product line of photoelectric, System Sensor's 100 Series smoke detectors may come in a small package low -profile smoke detectors but they pack some big benefits. A large, supervised terminal block SmartCheckTm diagnostics let you (patent pending) featuring captured SEMS screws simplifies installation. visually check sensitivity range SmartCheckTM self -diagnostics allow you to check the detector's sensitivity Isolated thermal models range by simply looking at the unit. Every ten seconds diagnostic circuitry Extensive two -wire compatibility monitors chamber sensitivity, checking to see if the detector is within its UL listings specification range. If it is, the LED flashes every ten seconds. If not, the LED stops flashing - a clear sign the detector needs cleaning or servicing. So, to "Twist -off" cleaning on standard see if a 100 series is within specification range, just look at it. This meets models only NFPA 72 requirements for sensitivity testing. For sensitivity readout, use MOD Sounder units feature built-in 400 accessory and voltmeter. temporal tone Heat Detection. Integrated thermal models provide restorable, 135 -degree Auxiliary Form C Relay units fixed -temperature heat detection. Isolated thermal models feature a fixed -tem - control elevator recall, door closure perature heat sensor that is isolated from the smoke sensor, providing a self -resetting, local audible smoke alarm. In these models only the isolated heat sensor will signal an alarm to the panel. The isolated thermal products are designed for applications where local annunciation, not total facility evacuation is desired. Sounder Models. A built-in piezoelectric horn (patent pending) in the 100 series sounder models produces the NFPA 72 -required, 85dBA temporal UL tone pattern when the individual detector alarms or when the supply voltage polarity is reversed. LISTED continued Standard Application Specifications - " Operating Voltage 12/24 VDC (nominal), 8.5 min. to 35 max. Standby Current 135°F electronic thermistor 50 pA maximum average Diameter Humidity Range 5.5 in. (140mm) 10% to 93% RH, noncondensing Fixed Temperature Heat Sensor 1 Height 1.9 in. (48mm) with bracket Weight 5.3 oz. (150 grams) Model Thermal Wiring I Temperature Range Alarm Current 21005 No 2 -wire 32° to 120°F (0° to 50°C) 100mA max. limited by panel 2100TS Yes 2 -wire 32° to 100°F (0° to 38°C) 100mA max. limited by panel 2112/24S No 4 -wire 32° to 120°F (0° to 50°C) 17mA typical, 23mA max. at 12V; 19mA typical, 25mA max. at 24V 2112/24TS Yes 4 -wire 32° to 100°F (0° to 38°C) 17mA typical, 23mA max. at 12V; 19mA typical, 25mA max. at 24V Auxiliary Form C Relay Specifications Auxiliary Contact Humidity Range Form C 10% to 93% RH, noncondensing Auxiliary Relay Contact Ratings 1A@30 VDC Diameter 5.5 inches (140mm) Height 1.7 inches (43mm) with bracket Shipping Weight 6.8 ounces (192 grams) Temporal Pattern Sounder Specifications Standby Current Fixed Temperature Heat Sensor 50 pA avg., 100 pA max. 135"F electronic thermistor Temperature Range 32°-100°F (0°-38°C) Humidity Range 10%-93% RH, noncondensing Diameter 5.5 in. (140mm) Height 2.05 in. (52mm) with bracket Shipping Weight 7.4 oz. (210 grams) System Sensor Canada System Sensor in China System Sensor— Far East 3825 Ohio Avenue Fixed Temperature Built -In Temp 3 Auxiliary Model Thermal Wiring Temperature Range Operating Voltage Heat Sensor Alarm Current Standby Current 2100TR* Yes 2 -wire 32° to 100°F 12/24 VDC (nominal) 135°F 100mA max. 50 pA average 1-800-736-7672x3 Fx: 011.44.1403.276501 Fx: 011.65.273.2610 (0° to 38°C) 8.5 min. to 35 max. electronic thermistor limited by panel 100 pA maximum 2112/24R* No 4 -wire 32° to 120°F 12/24 VDC (nominal) — 28mA typical 50 pA average No product specifications without notice. (0° to 50°C) 10 min. to 35 max. 35mA max. at 12V 10 min. to 35 max. 57MA typical, 65mA max. at 24V 36mA typical 2112/24ATR* Yes 4 -wire 12/24 VDC 49mA typical, 60mA max. at 12V 1A@30 VDC 45mA max. at 24V 2112/24TR* Yes 4 -wire 32* to 100°F 12/24 VDC (nominal) 135°F 28mAtypical 50 pA average (0° to 38°C) 10 min. to 35 max. electronic thermistor 35mA max. at 12V 36mA typical 45mA max. at 24V Temporal Pattern Sounder Specifications Standby Current Fixed Temperature Heat Sensor 50 pA avg., 100 pA max. 135"F electronic thermistor Temperature Range 32°-100°F (0°-38°C) Humidity Range 10%-93% RH, noncondensing Diameter 5.5 in. (140mm) Height 2.05 in. (52mm) with bracket Shipping Weight 7.4 oz. (210 grams) 2112/24AITR* Isolated 4 -wire 12/24 VDC 49mA typical, 60mA max. at 12V 1A@30 VDC 85dBA System Sensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor in China System Sensor— Far East 3825 Ohio Avenue Auxiliary Built -In Temp 3 Auxiliary Model Thermal Wiring Operating Voltage Alarm Current Consumption Contact Ratings Sounder Contact 210OAT* Yes 2 -wire 12/24 VDC 13mA min., 100mA max. — 85dBA No 1-800-736-7672x3 Fx: 011.44.1403.276501 Fx: 011.65.273.2610 8.5 min. to 35 max. Web: www.systemsensor.com 2112/24AT Yes 4 -wire 12/24 VDC 49mA typical, 60mA max. at 12V — 85dBA No product specifications without notice. 10 min. to 35 max. 57MA typical, 65mA max. at 24V 2112/24ATR* Yes 4 -wire 12/24 VDC 49mA typical, 60mA max. at 12V 1A@30 VDC 85dBA Form C 10 min. to 35 max. 57mA typical, 65mA max. at 24V 2112/24AITR* Isolated 4 -wire 12/24 VDC 49mA typical, 60mA max. at 12V 1A@30 VDC 85dBA System Sensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor in China System Sensor— Far East 3825 Ohio Avenue Ph: 905.812.0767 Ph: 011.86.29.524.6253 Ph: 011.852.21919003 St. Charles, IL 60174 Fx: 905.812.0771 Fx: 011.86.29.524.6259 Fx: 011.852.27366580 Ph: 800-SENSOR2 Fx: 630/377-6495 System Sensor in Europe System Sensor in Singapore System Sensor— Australia Documents on Demand Ph: 011.44.1403.276500 Ph: 011.65.273.2230 Ph: 011.613.54.281.142 1-800-736-7672x3 Fx: 011.44.1403.276501 Fx: 011.65.273.2610 Fx: 011.613.54.281.172 Web: www.systemsensor.com Page 2 © 1999 system Sensor The company reserves the right to change product specifications without notice. A05 -227-09.1/99(25K) •#400 0 , CALIF( IA DEPARTMENT OF FORESTRY & FIRE PR _CTION yi�,Me..m,c�r A OFFICE OF THE STATE FIRE MARSHAL C FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM F LISTING SERVICE LISTING No. 7272-1209:187 CATEGORY: Photoelectric Smoke Detector *REL Page 1 of 1 LISTEE: System Sensor, 3825 Ohio Ave., St. Charles IL 60174 Contact: Andrej Nikolic (630) 377-6674 DESIGN: Models 2100S, 2100TS, 2112/24S and 2112/24TS photoelectric type smoke detectors. Models 2100S and 2100TS are 2 -wire smoke detectors. Models 2112/24S and 2112/24TS are 4 -wire smoke detectors. Models 2100TS and 2112/24TS employ a supplemental thermistor type heat sensor. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5 - 32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and LIL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-3000 ft/min.. 01-13-99 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to-listee's data sheet, -installation instructions and/or other suitable information sources. Issued: J U N E 51 2000 Authorized By. live issue date to expiration date Listing Expires June 30, 2001 BEN HO, Supervising Deputy Program Manager