HomeMy WebLinkAbout066-310-024_3_21_06-2_12_08 (2)FIRE SAFETY INSPECTION REPORT 5� Butte County Fire Department California Department of Forestry and Fire Protection Orovi►le, California 95965 • (530) 538-7888 Business Address: ( l 'i i City. Inspection Date: Business Name: Business Phone: Owner/Property Management AP#: NO. CORRECTIONS REQURED NQ LOCATION I REMARKS CLEAR® LOCATION /JS 1 / d 1 Provide address numbers)bukliN I.D. visible from street EXITING 2 Remove obstructions at exits, doors, aisles, stairways, etc. 3 Exit door to open without a key or any special knxmlevge! effort. - 4 Repair exit door hardware. 5 Remove obstrwhorrs from door reclunred b be dosed. 6 Remove locks/latches from doors with panic hardware. 7 Provide sign over main exit door -'Thr door to remain unlocked during business hours'. 8 Remove storage from under unprotected staff 9 Providelmaintain exits niiemergency lighting. FIRE EKTINGUISHERS 10 Have fire edi cher s serviced and tagged. REINSPECTION DATES INSPECTOR 11 ProvkWmount fire extinguisher as indicated. 1st 'l / -) ('7 ' ^ / / I '(/ 12 Post a sign indicatingfire extinguisher location. 13 Provide clear access to fire extinguisher. 2nd FIRE PROTECTION EQUWMENT 14 Maintain, repair, paint, inspect, ardor test spnnkler/starxlp oe system/hydrant/FDC/PIV. Refer to FPB 15 Maintain 3 feet minimum clearance for access/use of fire appliances/equipment. District Attorney 16 Replace damage#ainted/missing sprinkler hea&gFDC caps. Final Clearance 17 Provide 5- ear certification test forsprinkler/standpipe system. ocapancyalss I ❑ Check Pre -Fire Plan for accuracy. 18 1 1 Provide spare sprinkler heads (min. 6) and/or compatible wrench. BY ORDER OF THE FIRE CHIEF You are hereby notified to correct all violations immediately or show cause why you should not be required to do so. A reinspection will be conducted on . Willful failure to comply with this notice is a misdemeanor. Violations that are not corrected immediately and/or remain after the reinspection may be processed as a criminal offense. Thank you for your assistance and cooperation in minimizing the fire and life loss in your community. 19 Hood/duct edinguishing system to be serviced/ tagged every 6 mo. 20 Remove grease from hood, duct, and filters. (KEEP CLEAN) FIRE ALARM SYSTEMS 21 Maintain, repair, inspect, and/or test fire alarm system. FIRE SEPARATIONS 22 Repair holes in required fire resistive construction. 23 Provider it self or automatic closing fire rated assemblies. 24 Keep attic access and scuttle openings closed. ELECTRICAL Signature of Recipient 25 Discontinue use of edension cords. 26 Install permanent wiring for fixed and stationary appliances. ❑ Owner ❑ Manager ❑ Employee ❑ Other 27 Provide cover plates for all junction boxes. Inspecting Officer: 28 Remove exposed wiring or protect in approved conduit. 29 Provide a 3Qinch clear space to and in front of electrical panel. FPB: -Engine Com 30 Maintain wiring in good condition and protect from damage. ❑ NO VIOLATIONS NOTED THIS DATE THANK YOU FOR BEING FIRE SAFE! FLAMMABLE LIQUIDS • COMPRESSED GASES 31 Provide a flammable liquid storage cabinet or reduce storage to 10 gallons or less. Addtional Comments: �,.� C Page_ of 32 Remove all flammable liquids not used for maintenance purposes. 33 Store flammable liquids from exits, stairs, or corridors. 34 Secure compressed gas cylinders. STORAGE • HOUSEKEEPINGL- 35 Arrange storage in an orderly manner to provide access/egress. 36 Remove combustible storage from water heater and electrical room. 37 Remove storage to 24 inches below ceiling or 18 inches below sprinkler heads. 38 Remove 1611debris from behind washers and dryers. 39 Remove waste/rubl ish ma+ -rials from the premises. 40 Keep dumpsters 5 feet away from combustible walls, eaves, or openings. MISCELLANEOUS 41 Other violations and/or comments. FIRE SAFETY INSPECTION REPORT Butte County Fire Department California Department of Forestry and Fre Protection Oroville, California 95965 • 538-7888 ass Address: ��fham (/1 /%</ `//r� (ill C/, ; C� !�//�� EusinessName: (Wmr/PropertyManagemerd:, Inspection Date:~/ Business Phone: / /-\aril NO. CORRECTIONS REOURED Na LOCATION I REMARKS CLEWED LOCATION 1 Provide address numbersibuilding I.D. visible from sheet EXi11t+IG yclo _ e;./QG/�lr 1 a /s 2 Remove obstructions at exits, doors, aisles, staff , etc. 3 Exit door to open without a key or any special knawbdget effort. 4 Repair ebt door hardware. 5 Remove obstrrctions from door recluired to be closed. 6 Remove locks/latches from doors with panic hardware. 7 Provide sign over main exit door -This door to remain unlocked during business hours". 8 Remove stuage from under unprotected staff `ur / 9 Praridelmaintain exit signilernergency lighting. FIRE EXTINGIMERS 10 Have fire exti is s serviced and tagged. REaNSPECIION DATES INSPECTOR 11 ProvkWmount fire Extinguisher as indicated. 1st / / 12 '' ` Post a sign irxficatifire extinguisher location. 13 Provide clear access to fire Extinguisher. 2nd / / FIRE PROTECTION EQt111`MENT 14 Maintain, repair, paint, inspect, ardor test sfxinkler/sbridpipe system/hydrant/FDC/PIV. Refer to FPB / / 15 Maintain 3 feet minimum clearance for access/use of fire appliances/equpment DstridAttomey / / 16 Replace damage#aintedrmssing sprinkler heads/FDC caps. Final Clearance / 1 17 1 Provide 5 -year certification test for sprnkledstandope system. Oca4mncv Cass ❑ Check Pre -Fire Plan for accuracy. 18 Provide sparesprinkler heads (min. 6) ardor compatible wrench. BY ORDER OF THE FIRE CHIEF You are hereby notified to correct all violations immediately or show cause why you should not be required to do so. A reinspection will be conducted on . Willful failure to comply with this notice is a misdemeanor. Violations that are not corrected immediately and/or remain after the reinspection may be processed as a criminal offense. Thank you for your assistance and cooperation in minimizing the fire and life loss in your community. 19 Hood/duct extinguishing tem to be servicecl/ tagged every 6 mo. 20 Remove grease from hood, duct, and filters. (KEEP CLEAN) FIRE ALARM SYSTEMS 21 Maintain, repair, inspect, and/or test fire alarm system. FIRE SEPARATIONS 22 Repair holes in required fire resistive contraction. 23 Providelrepair self or automatic closing fire rated assemblies. 24 Keep attic access and scuttle openings closed. ELECTRICAL Signature of Recipient: 25 Disconfinue use of extension cords. 26 Install permanent wirng for fixed and stationary appliances. ❑ Owner ❑ Manager ❑ Employee ❑ Other 27 Provide cover plates for all junction boxes. Inspecting Officer: 28 Remove exposed wiring or protect in approved conduit. 29 Provide a 30 -inch clear space to and in front of electrical panel. FPB: E ine Com 1 30 Maintain wiring in good condition and protect from damage. 0 NO VIOLATIONS NOTED THIS DATE THANK YOU FOR BEING ARE SAFE! FLAMMABLE LKWIDS • COMPRESSED GASES 31 Provide a flammable liquid storage cabinet or reduce storage to 10 gallons or less.mow/ Addtional Comments: r('ti i ��s r - /�9SS5tO Page of 32 Remove all flammable liquids not used for maintenance purposes. 33 Store flammable liquids away from exits, stairs, or comidas. 134 Secure compressed gas cylinders. STORAGE • HOUSEKEEPING 35 Amange stuage in an ordedy manner to acs/ 36 Remove combustible storage from water heater and electrical room. 37 Remove storage to 24 itches below ceiling or 18 inches belay sprinkler heads. 38 Remove Iiddeb is from behind washers and dryers. 39 Remove waste/rubbish me' -pals from the premises. 40 Keep dumpsters 5 feet away from combustible walls, eaves, or openings. MISCELLANEOUS 41 Other violations ardor comments. 9.. 35 nr-ar-�-iJ Rite Aid Corporation Store# 6548 14115 Lakeridge Circle Magalia, CA. 95954 Fire Alarm Monitoring System 24 HOUR MONITORING BY: AMCEST MONITORING SERVICES 1017 Walnut St Roselle, NJ. 07203 1-800-63I-7370 Installed By: Cornerstone Protective Services 2362 So. Whitney Blvd. Rocklin, CA. 95677 (916) 630-9484 Contractors LiQ. # 873739 REVIEWEI f3Y L_!FF'. ; AF TY OF =ICER 3Ui' I"E ;0. FIRE DEPT. -�<Pproved as submitted approved with conditions per dsheet a� 0 FIRE SAFETY INSPECTION REPORT Butte County Fre Department Califomia Department of Forestry and Fre Protection Oroville, California 95965 • (530) 538-7888 kniness Address: City Name: /Property Management: Inspection Date: ! /3/ /P 7' Business Phone: API#: NO. CORRECTIONS REQURED NQ LOCATION / REMARKS CLENW LOCATION 1 Provide address nLwnbffsbAdrxj I.D. visble from sheet EWING 2 Remove obstructions at exits, doors, aisles, stairways, etc. 3 Bat door to open without a key or any special knowledge) effort. / ! 4 Repair exit door Wdrrare. 5 Remove atsfnrcbons from door mqxed to be dosed. 6 Remove bds/latches from doors with panic hardware. 7 Provide sign over main exit door -'This door to remain unlocked during business hours'. 8 Remove storage from under unprotected staff ! / 9 ProviclMmaintam exit sKjrVemffgwq fighting. FIRE DXTINGLISHERS 10 Have fire s serviced and tagged. REINSPECTION DATES INSPECTOR 11 Providehnount fire extinguisher as indicated. 12 Past a sign indicating fire edinguisher location. 1st 13 Provide clear access to fire ednguisher. FIRE PROTECTION EQLWMENT 2nd / ! 14 Maintain, repair, paint, inspect, armor test sprinkledshandpipe system/hydranVFDC/PIV. Refer to FPB 15 Maintain 3 feet minimum clearance for access/use of fire appliances/equipment. District Attorney 16 Replace damagedrpaintedhnssing sprinkler heacis/FDC caps. Final Clearance ! / Provide 5 -year certification test for inklerlsta em. Class ❑ Check Pre -Fire Plan for accuracy. 18 Provide nkler heads min. ardor carr wrench. BY ORDER OF THE FIRE CHIEF j2017 19 Hoodfduct odd ushi serviced tem to be sertagged eve 6 mo. Remove reale from hood, dud, and filters. KEEP CLEAN) You are hereby notified to correct all violations immediately or show cause FIREALARM SYSTEMS why you should not be required to do so. A reinspection will be conducted on . Willful failure to comply with this notice is a 21 Maintain, repair, inspect, ardor test fire charm system. misdemeanor. Violations that are not corrected immediately and/or remain FIRE SEPARATIONS after the re -inspection may be processed as a criminal offense. Thank you 22 Repair holes in required fire resis0ve construction, for your assistance and cooperation in minimizing the fire and life loss in 23 Pro"repair self or automatic closing fire rated assemblies. your community. 24 Keep attic access and scuttle openings closed. ELECTRICAL ecipient Signature of Recipient- 25 25 Discontinue use of Wension cads. 26 Install permanent wiring for faed and stationary appliances. ❑ Owner ❑ Manager ❑ Employe e ❑ Other 27 Provide corerplates for all junction boxes. Inspecting Ofti er: 28 Remove exposed wiring or prated in approved conduit. 29 Provide a 304nch dear space to and in front of electrical panel. FPB: Engine Can 30 Maintain wiring in good condition and protect from damage. El NO VIOLATIONS NOTED THIS DATE THANK YOU FOR BEING FIRE SAFEI FLAMMABLE LIQUIDS • COMPRESSED GASES 31 Provide a flammable liquid storage cabinet or reduce storage to 10 gallons or Addfional Comments: less. 32 33 Remove all flammable liquids not used for maintenance purposes. Store flammable I' ids &hW from exits, stairs, or corridors. 34 Secure compressed gas cylinders. ""�✓ STORAGE • HOUSEKEBW 35 36 Arrange s in an orderly combustible frommanner taccess/ Remove combue sl from a water r heater and electrical room. P//q �4 �/ 37 Remove storage to 24 inches below cejIN or 18 inches below sprinkler heads. 38 Remove IinWebrs flan behind washers and dryers. 39 Remove wastes bbsh matwials frau the premises. 40 Keep dumpsters 5 feet away from conbustble walls, eaves, or openings. M1SCIELLANE0115 41 Other violations ardor comments. Page _� of f Mar, Sia 2007 1.2: 07PM _ Fri AW10W 1D No 3015159001 Serves Deter No Q Expires: 31- MA&A08 CE 11. TIFICATE COPOPLIA N. E T. W Is.TO 1 �th i e AMM SeMos Company . 1riefictedbee19,i�udedy Un.der�#erea .#m' (UL•in ts PmductW �Mark . 1 n'Sy.sW Tbeonly.&k�anc*'..of.' _PllamlftW�r Qh-.&ft-isthe-Wuanc9ofa GQM U.:� ... f 'the Alarm Sim and. t t •� t : i o r t' E=ULi4-wNWt6.-VerftaVon Serer. r ...� : ROSS N. -• • • . . .. ' . t A -L - - OR :s=ir .. ".. -�. •.; .- . •. •VT ..,.: • : . •�.,, , tip T`1 A1ac�n S�erv! e � #•,m tete t win Apu tate or • ' Eft Y21. ft "UU� . Iftmoi endlHi* Alur�n ��� , � ,,. �:�,�t�t�r'' . • .,{�!��?�i�r� ' . •• I ""Fkll$ CER-711F.IiC�4`F�EXRIRE&ON MwMAR4008 '"LOOK FOR THE EJB ALARM SYSTEM, CER. TFICAT-En I • MMM -2007. a M a Fano Page 1 � LEGEND F A C P New Fire Alarm Control Panel a Manual Pull Station H/S Horn /Strobe Tamper T Switch / P I V Water Flow F Switch OExisting Sprinkler Fire Riser Smoke ODetector S Above FACP Duct DS Smoke Detectors Fire E� Annunciator Bell Exterior Fire Bell Horn I -Strobe Ceiling Mount &S Strobe Rite Aid Corporation Store# 6548 14115 Lakeridge Circle Magalia CA. 95954 Fire Alarm Monitoring System Zone Configuration List 1 I Water Flow Switch 2 OS & Y Tamper Valves - (Supervisory) 3 Pull Stations - Front Entry Exit 4 Pull Stations - Front 5 I Pull Stations - Side Exit 6 I Pull Stations - Rear Exit 7 I Smoke Detector Above Panel 8 I Duct Smoke, Detectors RTU #I & RTU #2 (Supervisory) 9 ( Duct Smoke Detectors RTU #3 & RTU #4 (Supervisory) 10 I Not Used Rite Aid Corporation Store# 6548 14115 Lakeridge Circle Ma alia, CA. 95954 Fire Alarm Monitoring system Equipment / Parts -List Quantities Description Make Model# 1 Fire Alarm Control Panel Silent Knight SK 5208 1 Remote Annunciator Silent Knight SK 5235 4 Manual Pull Stations Firelite BG12 2 Strobes (Wall mount) System Sensor S1224MC 10 Horn/Strobes System Sensor P1224MC (Ceiling mount) 6 Horn/Strobe System Sensor P1224MC (Wall mount) 1 Smoke Detector System Sensor 2WB (Above Panel) 2 12V / 12AH Sealed Lead Tri Battery Tri-bdi 127 Battery CORNERSTONE Protective Services 2362 So. Whitney Blvd., Rocklin, CA. 95677 CA.#03550 CL# 873739 Telephone: (916) 630-9484 Fax: (916) 624-8035 Fire Alarm Systems Intrusion Alamt Systems Access Control Systems 24-hour Monitoring uence of operation ject Name: Rite Aid Corp Store #6548 Location: 14115 %keridge Circle Magalia CA, 95954 Date: 12'- 17 - 2007 5 ontrol Unit im; M "17 -111t -I MENNEEN *a- ter Flow Sw =�,—Ta m -per Valve Sw M M w M M M M M 0 0 0 M Man. Pull Station - Front En- Exit Manual Pull Station - Front E A t M M 11;i4 0 i M M M M 0 w 0 N M 0 0 M 0 0 Manual Pull Station - Side Exit _Z-4MW$aj:0; 'Manual Pull Station - Rear Exit M M 0IMP.44 OPM0.4 00M-4 0; 'j-4 M );'A 0;,Z! A MM 110 -MA 0;i-4 OE:1�4 pa4�m 0;iI4 MMMMM MENMENNE =',Smoke Detector above FACP Duct ►�►_�►_��►_t M M M _ems■��■■t■■ Global Project Values: Project Name: I Rite Aid 24 Project !D: I Store #6548 Alarm Mins: 5 0 Prepared By: Ron RatcBff Derating Factor: 1.55 Date: 1/15/2008 Voltage Drop Waming Threshold %: 10 Panel ID: SK -5208 I Model: SK -5208 Fire Alarm Control Panel Max NAC Current: 3.0 Amps Location: Mezzanine Volts: 24 VDC Max Panel Current: 6.0 Amps Ckt.# Qty Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Standby Alarm & Type 1000 Ft. One -Way Ohms EOL SK -5208 SK -5208 trol 1 0.140 0.160 NAC-CKT SK -5208 AC's 4 0-000 0.160 ALM-RLY SK -5208 RI 0.000 0.000 SK -5217 SK -5217 dr 0.000 0.000 SK -5235 SK -5235 ote 1 fflConMod 0.035 0.050 SK -5280 SK -5280 od 0.000 0.000 SK -5220 SK -5220 od 0.000 0.000 SK -7181 SK -7181 0.000 0.000 IDC -1 Water Flow Switch 0.000 0.000 IDC -2 Valve Tamper Switch 0.000 0.000 IDC -3 Pull Station #1 0-000 0.000 IDC -4 Pull Station #2 0.000 0.000 IDC -5 Pull Station #3 0.000 0.000 IDC -6 Pull Station #4 0.000 0.000 IDC -7 Smoke Detector above D.f{35, 0.095 IDC -8 Duct Detector RTU 1&2 0.000 0.000 IDC -9 Duct Detector RTU 3&4 0.000 0.000 IDC -10 0.000 0.000 IDC -11 0.000 0.000 IDC -12 0.000 0.000 IDC -13 0.000 0.000 IDC -14 0.000 0.000 IDC -15 0.000 0.000 IDC -16 0.000 0.000 IDC -17 0.000 0.000 IDC -18 0.000 0.000 IDC -19 0-000 0.000 IDC -20 0-000 0.000 IDC -21 0.000 0.000 IDC -22 0.000 0.000 IDC -23 0.000 0.000 IDC -24 0.000 0.000 IDC -25 0.000 0-000 IDC -26 0.000 0.000 IDC -27 0.000 0.000 IDC -28 0.000 0.000 IDC -29 0.000 0.000 IDC -30 0.000 0.000 NAC -1 Horn Strobe Cir 0.000 0.294 #16 Solid 4.02 160 1.29 20.02 1.85% NAC -2 Horn Strobe Cir 0.000 0.392 #16 Solid 4.02 140 1.13 19.96 2.16% NAC -3 Horn Strobe Cir 0.000 0.390 #16 Solid 4.02 120 0.96 20.02 1.84% NAC -4 Horn Strobe Cir 0.000 0.714 #16 Solid 4.02 200 1.61 19.25 5.63% Aux Aux Power Out 0.000 0.000 #18 Solid 6.39 0.00 20.40 0.00% Total Standby Current (Amps) 0.180 2.255 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes 160 5 Mins Total Standby AH Required 4.320 0.188 Total Alarm AH Required Total Combined AH Required 4.51 Command Shortcuts Multiply By The Derating Factor 1.55 - -- - - 1 Minimum BatteryAm Hours Reguired 6.99 l Configure Circuits J l Print Page Model 5208 Fire Alarm Control Panel with Digital Communicator The Fire Alarm Control Designed to Grow with Your Systems Needs, Without The Growing Pains. The SK -5208 is a microprocessor based control panel with built-in UL listed communicator designed for applications requiring smoke detection, manual pull stations, and sprinkler supervision. It features an easy to read LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 10 zones of initiation and is expandable up to 30 zones for larger applications. The SK -5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK -5208 delivers the performance to handle your installation. Features • 10 zones, 8 Class B (Style B) and 2 Class A (Style D) or Class B (Style B) zones, expandable to 30 zones • Supervised zone expanders and 1/0 modules can be mounted remotely from the main control panel Event History Buffer (150 events) with date/time stamp • All zones are compatible with. 2- or 4 -wire detectors • 8 selectable/programmable output patterns for notification appliance circuits • Built-in Digital Alarm Communicator Transmitter (DACT) • 4 Notification Appliance Circuits • 4 programmable general purpose relays • Programmable smoke verification, pre -alarm delay, cross zoning and enhanced verification mode features that can help minimize false alarms • Programmable from the built-in control panel touchpad, remote annunciator, or Windows® SKSS downloading software • Direct connect port for on-site up/downloading with Windows® SKSS downloading software Built-in walk test feature • Single or dual interlock water releasing capability • Plex door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions Programmable AC trouble relay • Built-in synchronization for appliances from AMSECO®, GenteO, Faraday, System Sensor@, and Wheelock® • Programmable date settings for Daylight Saving Time • Clock source setting options for 50 Hz, 60 Hz, or internal (uses the panel's internal clock) Specifications Operating Voltage: 24 VDC Primary AC: 120 Vrms @ 60Hz, 2A Total DC Load: 6 Amp Current Draw: Standby: 140 mA Alarm: 460 mA Flush Mounting Dimensions: Height: 24.75" (62.9 cm) Width: 14.5' (36.8 cm) Depth: 3-7/16" (8.73 cm) with 5/8" protruding Overall Dimensions: Height: 26-3/8" (67 cm) Width: 17-3/16" (43.66 cm) Total Depth: 4" (10.16 cm) Operating Temp: 32" to 120° F (0° to 49° C) Humidity: 10 - 93% noncondensing Optional Accessories • SK -5235 LCD Remote Annunciator • SK -5217 10 Zone Expander (2 max. per system) • SK -5280 Status Display Module (8 max. per system) • 7181 Fire Zone Converter • 5220 Direct Connect Module • 5824 Serial/Parallel Printer Interface Module SK -5208 • SKSS Downloading Software • Plex-2 Door Option Listings and Approvals • UL Listed • CSFM Listed • MEA approval 429-92-E Vol. XIII SILENT KNIGHT by Honeywell Model 5208 Fire Alarm Control Panel with Digital Communicator Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled/disabled as needed on a per job basis. In addition, the system will sound alarms locally for purpose of evacuation. Telephone Line 1 Telephone Line 2 Direct Connect For On -Site Pr 2 Class A (Style D) or Class B (Style B) Initiation Circuits 8 Class B (Style B) Initiation Circuits j To AC ogramming Programmable F Form C Relays :E :r Notification Appliance Circuits ' 5285 Remote ` Annunciators SBUS Devices 5280, 5217, & 5824 SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350318 Rev B, 11/05 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Copyright ©2005 Silent Knight Phone: (800) 328-0103, Fax: (763) 493-6475. LISTING No. CATEGORY: 1STEE: DESIGN: ALLATION: AL: CALIFORNIA DEPARTMENT OF FORESTRY 8 FARE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM ,LISTING SERVICE 7165-0559:137 Page 1 of 1 Control Unit (Non High -Rise) Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: Michael Mclsaac (763) 493-6400 FAX (763) 391-5464 Model *SK -5208 fire alarm control unit. Power -limited, automatic, manual, remote station, central station, waterflow, Releasing Device Service, and sprinkler supervisory services. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: SK5208 Control Unit SK -5220 Direct Connect Module SK -5280 Status Display Module SK -5217 Zone Expander SK -5235 Remote Annunciator SK -2194 Enclosure SK -7181 Zone Converter In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. This control unit can generate a distinctive three -pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002. Edition. Refer to manufacturers Installation Manual for details. This control unit meets the requirements of UL -864, 9t' Edition Standards 1. For the Alarm Verification Feature (delay of fire alarm), the maximum Retard/Reset/Restart shall not exceed 30 seconds. 2. Burglary and other non -fire functions were not examined. *RecerL 08-17-2006 jew This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 3, 2007 Listing Expires June 30, 2008 Authorized By- MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager SK -5235 Remote Annunciator Program and Operate the SK -5208 FRCP from a Distance with the SK -5235 Remote Annunciator. The SK -5235 remote annunciator provides remote annunciation for the 5208 Fire Alarm Control Panel. The SK - 5235 performs all system operations. It also provides trouble and alarm information and can be used for programming. The SK -5208 can support up to six 5235 Remote Annunciators. When the system is normal and Users identify themselves to the control panel by entering a code on the annunciator. When a user presses a button, the annunciator piezo beeps and the LCD prompts the user to enter a code or other relevant information. Multiple users can work at different annunciators simultaneously without affecting each other. mit 1±: • 2 -line 16 -character LCD display • Indicates Trouble, Alarm, Supervisory, and System Status conditions with LEDs and LCD display • Each SK -5235 is individually supervised by the SK -5208 FRCP. • Up to 6 per SK -5208 FACP • Operation and appearance comparable to the control panel's on -board annunciator • Can be wired up to 1500 ft from FACP SK -5235 Remote Annunciator spedfications Operating Temp: 32' to 120° F Operating Voltage: 24 VDC (0' to 49' C) Current Draw: Maximum Wiring Standby: 30 mA Distance: 1500 ft. Alarm: 50 mA Dimensions: Width: 7-3/16" (18.26 cm) Height: 5" (12.7 cm > SILENT Depth: 1-1/8" KNIGHT (2.86 cm) SK -5235 Remote Annunciator Engineering Spedfiicatians The contractor shall furnish and install where indicated on the plans, the Model SK -5235 Remote Annunciator. Module shall be of a LCD type with a 2X16 display. Module shall be capable of remote programming as well as providing alarm, trouble information along with resetting of alarms and silencing of trouble and alarm conditions. Module ID shall be programmed with a 4 position DIP The control shall be capable of supporting up to 6 supervised SK -5235. Module shall be designed to mount on a dual gang electrical box with 18 gauge to 14 gauge wire. SILENT KNIGHT 7556 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 612-493-6435 FAX: 612-493-6475 World Wide Web: http:;/wevw.silentknight.com MADE IM AMERICA FORM# 350321, 01100 Coayright 0 2000 Silent Knight CALIFORNIA DEPARTMENT OF FORESTRY 8 FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:137 Page 1 of 1 CATEGORY: Control Unit Non High -Rise) 'EE: Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: Michael Mclsaac (763) 493-6400 FAX (763) 391-5464 IGN: Model *SK -5208 fire alarm control unit. Power -limited, automatic, manual, remote station, central station, waterflow, Releasing Device Service, and sprinkler supervisory services. Refer to listee's data sheet fior additional detailed product description and operational considerations. System components: SK5208 Control Unit SK -5220 Direct Connect Module SK -5280 Status Display Module SK -5217 Zone Expander SK -5235 Remote Annunciator SK -2190 Enclosure SK -7181 Zone Converter NSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances 11 and in a manner acceptable to the authority having jurisdiction. IAARKING: Listee's name, model number, electrical rating and UL label. kPPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. This control unit can generate a distinctive three -pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NEPA 72, 2002 Edition. Refer to manufacturers Installation Manual for details. This control unit meets the requirements of UL -864, 9 h Edition Standards. NOTE: 1. For the Alarm Verification Feature (delay of fire alarm), the maximum Retard/Reset/Restart shall not exceed 30 seconds. 2. Burglary and other non -fire functions were not examined. *Recent. 08-17-2006 jew This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement, or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date issued: JUNE 3, 2Q07 Listing Expires June 30, 2008 Authorized By.- MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager July 14, 2004 DF -52004 F-050 • Fire•LITerALarmsBG-12 Series Manual Fire Alarm Pull Stations www.firelite.com Section: Conventional Initiating Devices GENERAL The Fire -Lite Alarms BG -12 Series is a cost-effective, fea- ture -packed, non -coded series of manual fire alarm pull stations. It was designed to meet multiple applications with the installer and end-user in mind. The BG -12 Series features a variety of models including single- and dual - action versions. The BG -12 Series provides Fire -Lite Fire Alarm Control Panels (FACPs), as well as other manufacturers' controls, with a manual alarm initiating input signal. Its innovative design, durable construction, and multiple mounting op- tions make the BG -12 Series simple to install, maintain, and operate. FEATURES • Aesthetically pleasing, highly visible design/color. • Attractive contoured shape with light textured finish. • Meets ADA 5 Ib. maximum pull -force. • Meets UL 38, Standard for Manually Actuated Signaling Boxes. • Easily operated (single- or dual -action), yet designed to prevent false alarms when bumped, shaken, or jarred. • PUSH IN/PULL DOWN handle latches in the down po- sition to clearly indicate the station has been operated. • The word "ACTIVATED" appears on the top of the handle in bright yellow, further indicating operation of the sta- tion. • Operation handle features white arrows showing basic operation direction, for non -English-speaking persons. • Braille text included in finger -hold area of operation handle and across top of handle. • Multiple hex- and key -lock models available. • U.S. patent -pending hex -lock needs only a quarter -turn to lock/unlock. • Station can be opened for inspection and maintenance without initiating an alarm. • Product ID label viewable by simply opening the cover; label is made of a durable long -life material. • The words "NORMAL" and "ACTIVATED" are molded into the plastic adjacent to the alarm switch (located in- side). • Four -position terminal strip molded into backplate. • Terminal strip includes Phillips combination -head cap- tive 8/32 screws for easy connection to Initiating Device Circuit (IDC). • Terminal screws backed -out at factory and shipped ready to accept field wiring (up to 12 AWG/3.25 mm2). California State Fire -' _ Marshal 1i ®� us a` 7150-0075:184 LISTED FM MEA 67-02-E APPROVED • Terminal numbers are molded into the backplate, elimi- nating the need for labels. • Switch contacts are normally open. • Can be surface (with SB -1/0 or SB -10) or semi -flush mounted. Semi -flush mount to a standard single -gang, double -gang, or 4" (10.16 cm) square electrical box. • Backplate is large enough to overlap a single -gang backbox cutout by up to 1/2" (12.7 mm). • Optional trim ring (BG -TR). • Spanish version (FUEGO) available (BG-12LSP). • Designed to replace the Fire -Lite Legacy BG -10 Series. • Models packaged in attractive, clear plastic (PVC), clamshell -style, Point -of -Purchase packages. Packag- ing includes a cutaway dust/paint cover in shape of pull station. Fire-Lite(g) Alarms is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep 'SO 9oo� our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. - ZVI =11 11-3-1611 For more information, contact Fire -Lite Alarms, One Fire -Lite Place, Northford, H16111EF111101MAN RFACTRRING Connecticut 06472. Phone: (800) 627-3473, Toll -Free FAX: (877) 699-4105. 0 ®A L I T Y SYSTEMS DF -52004 • 07/14/04 — Page 1 of 2 CONSTRUCTION • Cover, backplate and operation handle are all molded of durable polycarbonate material. • Cover features white lettering and trim. • Red color matches System Sensor's popular SpectrAlertTM hom/strobe series. OPERATION The BG -12 manual pull stations provide a textured finger - hold area that includes Braille text. In addition to PUSH IN and PULL DOWN text, there are arrows indicating how to operate the station, provided for non -English-speaking persons. Pushing in and then pulling down on the handle activates the normally -open alarm switch. Once latched in the down position, the word "ACTIVATED" appears at the top in bright yellow, with a portion of the handle protruding at the bottom as a visible flag. Resetting the station is simple: insert the key or hex (model dependent), twist one quar- ter -tum, then open the station's front cover, causing the spring-loaded operation handle to return to its original position. The alarm switch can then be reset to its normal (non -alarm) position manually (by hand) or by closing the station's front cover, which automatically resets the switch. SPECIFICATIONS Physical Specifications: 52004 t t .tb! Electrical Specifications: Switch contact ratings: gold-plated; rating 0.25 A @ 30 VAC or VDC. ENGINEERS' & ARCHITECTS' SPECIFICATIONS Manual Fire Alarm Stations shall be non -code, with a key - or hex -operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key or hex. An operated station shall automatically condition it- self so as to be visually detected as activated. Manual stations shall be constructed of red colored LEXAN® (or polycarbonate equivalent) with clearly visible operating in- structions provided on the cover. The word FIRE shall ap- pear on the front of the stations in white letters, 1.00 inches (25.4 mm) or larger.* Stations shall be suitable for sur- face mounting on matching backbox SB -10; or semi -flush mounting on a standard single -gang, double -gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabili- Page 2 of 2 — DF -52004.07114104 ties Act (ADA) or per national/local requirements. Manual Stations, shall be Underwriters Laboratories listed. *NOTE. The words "FIRE/FUEGO" on the BG-12LSP shaii ap- pear on the front of the station in white letters, approximately 3/ 4" high. PRODUCT LINE INFORMATION ao 11 11a�o a11 -to 00-10 a1111 1111m00 55 ®11 5.601 ®0 55 ®11 6.0 ®11 4.25 switch, screw terminal connections, hex lock. 03.97m) (14.230 (13.97 111) (15.24m) (10.79 00) (FIREIFUEGO) labeling. 4.121 4.222 ®0 4.121 4.69 MM 4.25 ing gasket. (10.4700) (10.72m) (10.47®) (11.9100) (10.79[11) a Oar: 139 ®1I 1.439 EMG 1375 MEG 2-0 llOi3tJ 1.75 �a (FIRE/FUEGO) labeling. (3-5309) 9) (3.66 m) (3 49 ®) (5.0$ m) (4.445 00 ) 52004 t t .tb! Electrical Specifications: Switch contact ratings: gold-plated; rating 0.25 A @ 30 VAC or VDC. ENGINEERS' & ARCHITECTS' SPECIFICATIONS Manual Fire Alarm Stations shall be non -code, with a key - or hex -operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key or hex. An operated station shall automatically condition it- self so as to be visually detected as activated. Manual stations shall be constructed of red colored LEXAN® (or polycarbonate equivalent) with clearly visible operating in- structions provided on the cover. The word FIRE shall ap- pear on the front of the stations in white letters, 1.00 inches (25.4 mm) or larger.* Stations shall be suitable for sur- face mounting on matching backbox SB -10; or semi -flush mounting on a standard single -gang, double -gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabili- Page 2 of 2 — DF -52004.07114104 ties Act (ADA) or per national/local requirements. Manual Stations, shall be Underwriters Laboratories listed. *NOTE. The words "FIRE/FUEGO" on the BG-12LSP shaii ap- pear on the front of the station in white letters, approximately 3/ 4" high. PRODUCT LINE INFORMATION Model Description BG -12S Single-action pull station with pigtail connec- tions, hex lock. BG-12SL Same as BG -12S with key lock. BG42 Dual -action pull station with SPST N/O switch, screw terminal connections, hex lock. BG4 2L Same as BG -12 with key lock. BG-12LSP Same as BG -12L with English/Spanish (FIREIFUEGO) labeling. BG-12LOB Same as BG -12L with "outdoor use"' listing. Includes outdoor listed backbox, and seal- ing gasket. BG-12LO Same as BG -12L with "outdoor use" listing. Does not include backbox. BG-12LA Same as BG -12L with auxiliary contacts. BG-12LPS Same as BG -12L with presignal feature. BG-12LPSP Same as BG-12LPS with English/Spanish (FIRE/FUEGO) labeling. SB -I/0 Indoor/outdoor backbox. SB -10 Indoor use backbox. WP -10 Outdoor use backbox. WBB Outdoor use backbox. 17003 Key lock. 17007 Hex lock. 1.390" (35.306) CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM i' LISTING SERVICE LISTING No. 7150.0075:184 Page 1 of 1 CATEGORY: Boxes/Pull Stations LISTEE: Fire -Lite Alarm Inc., One Fire -Lite Place, Northford CT 06472-1653 Contact: Brian Reynolds *(203) 484-7161 FAX (203) 484-7309 DESIGN: Models BG -12, BG -12S, BG-12NC, BG -12W, BG-12LW, BG-12WP, BG-12LWP, BG -12L, BG-12LX, BG-12LA, BG-12PS, BG-12LSP, BG-12SP, BG-12LR, BG-12LRA, BG-12LAO, BG-12LAOB, BG -12 -LO, BG-12LOB, BG-12LPS, BG-12LPSP, BG-12SL, *UT -PSI and UT- PS2 fire alarm pull boxes. The BG -12 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models BG-12WP, BG -12W, BG-12LW and BG-12LWP are intended for outdoor use when installed with Model WP -10 back box. Models BG-LAOB and BG-12LOS are intehded for outdoor use when installed with Model WBB or WP -10 back box. XLF: 7150-0028:199 *Rev. 05-06-05 JEW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is. not ars endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date issued: JUNE 3, 2007 Listing Expires June 30, 2008 Authorized By. MIKE TANA KA, Senior Deputy State Fire Marsha! Program Manager Models Available Two -Wire Models 2W -B 2WT-B 2 -wire standard 2 -wire standard with thermal Four -Wire Models 4W-13 4 -wire standard 4WT-B 4 -wire standard with thermal Accessories 2W-MOD2 2 -wire loop test/maintenance module SENS-RDR Sensitivity reader RT Removal/replacement tool A77-AB2 Retrofit adapter bracket Product Overview Plug-in detector line — mounting base System Sensor's i3"" series smoke detectors represent a significant advancement in included conventional detection. The P family is founded on three principles: Installation ease, Intelligence, and Instant inspection. Large wire entry port In-line terminals with SEMS screws Installation ease. The i3 line redefines installation ease with its plug-in design. This allows an installer to pre -wire the bases included with the heads. The large Mounts to octagonal and single -gang wire entry port and in-line terminals provide ample room for neatly routing the backboxes, 4 -square backboxes, or wiring inside the base. The base accommodates a variety of back box mount - direct to ceiling ing methods as well as direct mounting with drywall anchors. To complete the installation, i3 heads plug-in to the base with a simple Stop -Drop 'N Lock Stop -Drop 'N Lock- attachment to base action. Removable detector cover and chamber Intelligence. 13 detectors offer a number of intelligent features to simplify for easy cleaning testing and maintenance. Drift compensation and smoothing algorithms are standard with the i3 line, to minimize nuisance alarms. When connected to the Built-in remote maintenance signaling 2W-M0D2 loop test/maintenance module, or a panel equipped with the i3 protocol, 2 -wire i3 detectors are capable of generating a remote maintenance Drift compensation and smoothing signal when they are in need of cleaning. This signal is indicated via an LED algorithms located at the module and the panel. To read the sensitivity of 13 detectors, the Simplified sensitivity measurement SENS-RDR is a wireless device that displays the sensitivity in terms of percent per foot obscuration. Wide angle, dual color LED indication Instant inspection. The i3 series provides wide angle red and green LED indica- Loop testing via EZ Walk feature tors for instant inspection of the detector condition, indicating: normal standby, out -of -sensitivity, alarm, or freeze trouble conditions. When connected to the Built-in test switch 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol, MEA the EZ Walk loop test feature is available on 2 -wire i3 detectors. This feature �� FM verifies the initiating loop wiring by providing LED status indication at each MSM® LISTED approved approved detector. 5911 3011446 72721209:210 290-01-E 2093 Architect/Engineer Speciflcations Smoke detector shall be a System Sensor i3 Series model number_,, listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a photoelectric type (model 2W -B, 4W -B) .or a combination photoelectric! thermal (model 2WT=B, 4WT B) with ther- mal sensor rated at 1.35°F (57.2°C). The I detector shall include a mounting base for mounting to 31h -inch and 4 -inch octagonal, single gang, and 4 -inch square back boxes Electrical SDeclfications with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring con- nections shall be made by means of SEMS screws. The detector shall allow pre -wiring of the base and the head shall be a plug- in type. The detector shall have a nomi- nal sensitivity of 2.5% per foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual color LED indication which blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (model 2WT B, 4WT B) conditions. When used in conjunc- tion with the 2W MOD2 module, 2 -wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel, and shall provide a loop testing capability to verify the circuit without testing each detector individually. Operating Voltage Standby Current Peak Standby Current Nominal: i2/24V non -polarized 2 -wire: 50 NA maximum average 2 -wire: 100 pA Min.: 8.5V 4 -wire: 50 NA maximum average 4 -wire: n/a Max • 35V Physical Snecifications Operating Temperature Range Sensitivity Maximum Alarm Current Alarm Contact Ratings Maximum Ripple Voltage 2 -wire: 130 mA limited by control panel 2 -wire: n/a 30% peak to peak of applied voltage 4 -wire: 20 mA @12V, 23mA @ 24V 4 -wire: 0.5 A @ 30V AC/DC LED Modes Single gang back box Power Up Sequence for .LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Fx: 44.1403.891921 Fx: 65.6273.2610 Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Physical Snecifications Operating Temperature Range Sensitivity Mounting . 2W -B and 4W-6: 320F-120OF (0°C --490C) 2.5%/ft. nominal 3Y -inch octagonal back box 2WT-B and 4WT-8: 320F 100°F (0°C -37.80C) 130 mA max. limited by control panel 4 -inch octagonal back box Yes Input Terminals Single gang back box Operating Humidity Range 14-22 AWG 4 -inch square back box with a plaster ring 0 to 95% RH non -condensing Dimensions (including base) Direct mount to ceiling Thermal Sensor 5.3 inches (127 mm) diameter 135°F (57.2°C) fixed 2.0 inches (51 mm) height Freeze Trouble 2WT-B and 4WT-B only: 41°F (5°C) Ordering Information Weight 6.3 oz. (178 grams) Model Thermal Wiring Alarm Current 2W -B No 2 -wire 130 mA max. limited by control panel 2WT-8 Yes 2 -wire 130 mA max. limited by control panel 4W -B No 4 -wire 20 mA @ 12V, 23mA @ 24V 4WT-B Yes 4 -wire 20 mA @ 12V, 23mA @ 24V Model Description 2W-MOD2 2 -wire loop test / maintenance module SEMS-RDR Sensitivity reader RT Removal / replacement tool A77-AB2 Retrofit adapter bracket, 6.6 in. (16.76cm) diameter System Sensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor In China System Sensor — Far East System Sensor — India 3825 Ohio Avenue Ph: 905.812.0767 Ph: 86.29.8832.0119 Ph: 85.22.191.9003 Ph: 91.124.637.1770 x.2700 St. Charles, IL 60174 Fx: 905.812.0771 Fx: 86.29.8832.5110 Fx: 85.22.736.6580 Fx: 91.124.637.3118 Ph: 800/SENSOR2 Fx: 630/377-6495 System Sensor Europe System Sensor In Singapore System Sensor — Australia System Sensor — Russia Ph: 44.1403.891920 Ph: 65.6273.2230 Ph: 613.54.281.142 Ph: 70.95.937.7982 www.systemsensor.com Fx: 44.1403.891921 Fx: 65.6273.2610 Fx: 613.54.281.172 Fx: 70.95.937.7983 0 2004 System Sensor. The company reserves the right to change product specifications without notice. A05.0318-005.6/04•#1280 LISTING No. CATEGORY: LISTEE: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LASTING SERVICE 7300-1653:166 Misc. Devices/Control Unit Accessories Page 1 of 1 System Sensor, Unincorporated Div. of Honeywell Int'l Inc., 3825 Ohio Avenue, St Charles IL 60174 Contact: Trish Linhart (634) 377-6580 ext. 1185 FAX (630) 377-7245 DESIGN: Model 2W-MOD2 maintenance module. Intended to be connected to Models 2W-13 and 2WT-13 (CSFM Listing No. 7272-1653:152) as well as Models 2WTA-B and 2WTR-B (CSFM Listing No. 7272-1653:164) smoke detectors. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 8.5-30 V dc, 90 m A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a maintenance module for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1209:226 os-20-OSKK This listing is based upon technical data submitted by the applicant. CSFM Firs Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any dairns. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date issued: JUNE 8, 2007 Listing Expires Jure 30, 2008 Authorized By. MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager Model DH100ACDCLP 4 -Wire Photoelectric Duct Smoke Detector with Low -Flow Technology Product Overview Air velocity rating from 100 to 4000 feet per minute (0.5 to 20.32 m/sec.) Patented interconnectabiility for multi4an shutdown (up to ten air handlers) Patented telescopic sampling tube Patented cover tamper trouble signal 24 VAC/DC or 120/240 VAC operation High -Low voltage barrier Equipped with two DPDT Form C relay contacts Built-in reset button Outside mounting tabs Easy and quick mounting to round or rectangular ducts from V-12' (0.3-3.7 meters) wide Easy to clean UL recognized field -replaceable power and sensor boards Remote test station option Remote sounder option Transparent cover for convenient visual inspection UL 268A listed 3 -year warranty V� LISTED The System Sensor Innovair'' DH100ACDCLP is a 4 -wire photoelectric air duct smoke detector capable of sensing smoke in air velocities from 100 to 4,000 feet per minute (0.5 to 20.32 m/sec). This Innovair features Low -Flow technology that enables duct smoke detection throughout a broad range of airflow environments. Many difficult to solve HVAC applications occur in low airflow duct applications where reliable smoke detection is critical. Innovair with Low -Flow technology can detect smoke at air speed velocities of 100 feet per minute or greater, while continuing the same reliable performance to 4,000 feet per minute. The two available form C relay contacts provide reliable performance for the management of fans, blowers and air conditioning systems. These HVAC devices can be configured to prevent the spread of toxic smoke and fire gasses through a protected area The Innovair family is designed for simplified installation and easy mainte- nance. The modular construction allows for easy cleaning and uncomplicated field replacement of the UL recognized power and sensor boards. The patented cover missing feature insures the cover is securely tightened following routine cleaning and maintenance. The patented interconnectability feature allows multiple Innovairs to communicate with each other. In the event smoke is detected, the Innovair will signal the remaining interconnected detectors to initiate their relays for smoke control. WARNING: Duct smoke detectors have specific limitations. DUCT SMOKE DETECTORS ARE: NOT a substitute for an open area smoke detector, NOT a substitute for early warning detection, and NOT a replacement for a building's regular fire detection system. Refer to NFPA 72 and 90A for additional information about the proper application of duct smoke detectors. ArchitecturaVEngi'ineering Speciflcations The air duct smoke detector shall be a System Sensor Model DH100ACDCLP Series Duct Smoke Detector. The detector hous- ing shall be UL listed per UL 268A specifically for use in air handling systems. The detector shall operate at air velocities of 100 feet per minute to 4000 feet per minute (0.5 to 20.32 m/sec.). The .unit shall be capable of controlling up to ten (10) air handling systems when interconnected with other detectors. The detector shall be capable of providing a trouble signal in the event that the front cover is removed. It shall be capable of local testing via magnetic switch or remote testing using the SSK451 Multi -Signaling Accessory or the RTS451KEY Remote Test Station. The unit shall be reset by local reset button or remote test station. The duct smoke detector housing shall incorporate an airtight smoke chamber in compliance with UL 268A, Standard for Smoke Detectors for Duct Applications. The housing shall be capable of mounting to either rectangular or round ducts without adapter brackets. An integral filter system shall be included to reduce dust and residue effects on detec- tor and housing, thereby reducing maintenance and servicing. Sampling tubes shall either be telescoping or be easily installed by passing through the duct housing after the housing is mounted to the duct. The unit shall provide a spacial separation of no less than 1/4" (6.4 mm) and/or a physical barrier between the high and low voltage terminals. The enclosure shall meet all applicable NEC and NFPA standards regarding electrical junction boxes. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. Wiring Guide System wiring diagram for 4 -wire duct smoke detectors I- - AVAILABLE POWER INPUTS I I AVAILABLE POWER INPUTS I CONNECT POWER SOURCE Pgmel ACCEPT I9 10 A B C I I 8 10 A B C I TQ APPROPRIATE TERMINALS 24 VDC. 24 AC 5060 HZ, OF EACH DETECTOR. SEE 120 VAC: OR 220/240 VAC 60-60 60 H7_ I I I I SPECIFICATIONS FOR CONNECT POWER SOURCE I I 1 I I A DPOWER SUPPLY TO APPROPRIATE lav t24v INFORMATION. OF cw DETECTOR. y LVAC I I 220!240 I I 220/240 VAC 1 I VACALARM AUXILIARY I I ALARM AULIARY FOR FAN SHUTDOWN C CONTACTS I I OR FAN XISHUTDOWN, I AUX, CONLUa BONGS 1 16 6 17 7 18 8 1 1 16 6 17 7 1a a 10A 0 30 VDC RESISTIVE II CIA 0 250 VAC & & & 0 0 & & & 0 0 FOR V41RING I 100MA MINIMUM 0� 5 VDC I N. C N.O. N.O. .C. I I N.0 C. N.O. N.O. .C. I DEVICES, REFER TO LIARY NOT INTENDED FOR � I � I MANUFACTURER'S CONNECTION TO CONTROL I I I ( INSTALLATION INSTRUCTIONSFAURE PANELS. , I I I OR CONTACT MANUFACTURER. l ALARM AUXILIARY CONTACTS SHOWN IN I I ALARM AUXILIARY CONTACTS SHOWN IN I NATE; THE SUPERVISORY RELAY NOW STANDBY. CONTACTS 1 ALARM AS (INDICATED BY THE ARROWS. 1 I ALARM ARING STANDBY.S INDICATED NTACTS BYNTHEEAARRROWS. PROVIDES A'FORM C' CONTACT FOR cusTOMl2ED APPLICATIONS. I I1 1 TOI•IE'NO�' CONTSTANDARD ACT SUS- APPLICATIONS, ONLY TACT TROUBLE INRATING I SUPERVISORY TROUBLE CONTACTS I SUPERVISORY TROUBLE CONTACTS 2.0 A® 30 VDC resistive 1 14 3 I I 14 3 1 1— 1 2.0 A 0 125 VAC resistive I I i I I TROUBLE CONTACTS CLASED IN ALARM AND STANDBY. TROUBLE CONTACTS CLOSED IN ALARM AND STAAEDBY, l CONTACTS OPEN WHILE DETECTOR PC8 OR POWER IS CONTACTS OPEN WHILE DETECTOR PCB OR POWER IS REMOVED OR WHEN TAMPER FEATURE 71MES OLM OPEN REMOVED OR WHEN TAMPER FEATURE TIMES OUT. OPEN CONTACTS SIGNAL TROUBLE CONDITION TO PANEL CONTACTS SIGNAL TROUBLE CONDITION TO PANEL l 1 1 l I I + I 5 TOPEN ALARM ALARM CONTACTS SHOWN ALARMNTACTS SHOWNINITIATION INITIATION OPEN IN STANDBY. INITIATION IN STANDBY. LOOP CONTACTS CONTACTS CLOSE CONTACTSNTACTS CLOSE I IN ALARM. IN ALARM. I 4 4 1 - / ` I UL LISTED 4 -WIRE FIRST DETECTOR IN THE LOOP LAST DETECTOR IN THE LOOP EOL RESISTOR CONTROL PANEL DH100ACDCLP DH100ACDCLP SPECIFIED BY PANEL MANUFACTURER Specifications Size Storage Temperature Range 143rd" (37 cm.) Length —220 to +158°F (-300 to +70°C) 51f�" (14 cm.) Width 23/4" (7 cm.) Depth Operating Humidity Range Shipping Weight 10% to 93% relative humidity rion-condensing 33/4 lbs. (1.7 kg.) Air Duct Velocity Operating Temperature Range 1.00 to 4000 ft./min. (0.5 to 20.32 m/sec.) • _ 320 to 131°F (0° to 55°C) Electrical Ratings - DH100ACDCLP (Includes Detector) Power supply voltage: 20-29 VDC 24 VAC 50 -60 -Hz 120 VAC 50-60 Hz 220/240 VAC 50-60 Hz Input capacitance: 270 PF max. 270 pF max. N/A N/A Reset voltage: 3.0 VDC min. 2.0 VAC min. 10 VAC min. 20 VAC min. Reset time (with RTS451): .03 to 0.3 sec. .03 to 0.3 sec. .03 to 0.3 sec. .03 to 0.3 .sec. Reset time (by power down): 0.6 sec. max. 0.6 sec. max. 0.6 sec. max. 0.6 sec. max. Power up time: 34 sec. max. 34 sec. max. 34 sec. max. 34 sec. max. Alarm response time: 2 to 17 sec. 2 to 17 sec. 2 to 17 sec. 2 to 17 sec. Sensitivity Test: See detector label See detector label See detector label See detector label Power Supply Voltage 20 - 29 VDC 24 VAC 50 - 60 Hz 120 VAC 50 - 60 Hz220/240 VAC 50 - 60 Hz CURRENT REQUIREMENTS (USING NO ACCESSORIES) 5 Max standby current 15 mA 35 mA RMS 25 mA RMS` 15 mA RMS* Max. alarm current 70 mA 125 mA RMS 35 mA RMS* 25 mA RMS* CONTACT RATINGS Alar initiation contacts (SPST) 2.0A @ 30 VAC/DC (0.6 power factor) Alarm auxiliary contacts (DPDT) 10A @ 30 VDC 10A @ 250 VAC Note: Alarm auxiliary contacts must switch 100mA minimum at 5VDC. Alarm auxiliary contacts shall not be connected to inititaing circuits of control panels. Use the alarm initiation contact for this purpose. Trouble contacts (SPDT) 2.OA 0 30 VDC (resistive) 2.OA ®125 VAC (resistive) Wiring diagram for DH100ACDCLP to APA451: DH100ACDCLP APA451 Alarm Signal 15 2 Alarm (Red LED) Aux. Power + i 9 Sup. N. O. Sup. COM3 3 Power (Green LED) Aux. Power — 20 1 Common NOTE: Wiring diagram shown Is for DH100ACDCLP 4 -wire duct smoke detector system equipped without a control panel. NOTE: A trouble condition is Indicated when the green LED is not Illuminated. Wiring diagram for the DH100ACDCLP to RTS451/ RTS451KEY: DH100ACDCLP DEVICE STANDBY RTS451/RTS451 KEY Alarm Signal 15 12.5mA Max. 1 (Red LED) Alarm 3OmA Max. — — — — — — — — — — — — — — — — — — — --* l Aux. Power + 19 OmA *For RTS451 KEY l I Sup. N. O. 14 12mA* only., without a 1 control paw. ) Su . COM P 3 5rnA Max. 6 Green LED ( ) 30mA Max. Power Aux. Power - 20 2 Reset 2 3 4 Test 11 5 *NOTE: For RTS451 KEY only without a Control Panel. RTS451 does not have a terminal 6. NOTE: Wiring diagram shown Is for DH100ACDCLP 4 -wire duct smoke detector system equipped without a control panel. NOTE A trouble condition is Indicated when the green LED is not filuminated. ACCESSORY CURRENT LOADS AT 24 VDC DEVICE STANDBY TROUBLE ALARM APA451 12.5mA Max. n/a 3OmA Max. PA400 OmA n/a 15mA Max. RA40OZ OmA n/a 1 OmA Max. RTS451/RTS451KEY 12mA* n/a 7.5mA Max SSK451 5rnA Max. 9mA Max. 30mA Max. *NOTE: When a unit is powered at the 120VAC or 220/240VAC input, any combination of accessories may be used such that the given accessory loads are: 60 mA or less In the standby state; 110 mA or fess In the alarm state. Important Interconnect Notes • When using the interconnect feature, all interconnected units must be powered with the same, independent supply. • Polarity must be maintained throughout the interconnect wiring. Connect terminal 12 on unit 1 to terminal 12 on unit 2 and so on. Similarly, connect terminal 1 on unit 1 to terminal 1 on unit 2 and so on. • Up to 10 units may be interconnected. Wiring diagram for DH100ACDCLP to SSK451: FIELD INSTALLED JUMPER FOR TEMPORAL PATTERN ssicas1 COMMON* 3 TEMPORAL SELECT �@@ ALARM SIGNAL 1 SUPERVISORY SIGNAL 4 RESET TEST POWER (-) POWER (+) DH100ACDCLP 15 ALARM SIGNAL 3� SUPERVISORY 14 CONTACT �2 RESET 11 TEST 1@ AUX. POWER (-) 19 AUX. POWER (+) FIELD INSTALLED JUMPER Wiring diagrams for optional accessories: 15 +) ALARM SIGNAL. (+) I I � � AUX POWER H DUCT DETECTOR DH100ACDCLP 5 NO ALARM SIGNAL (+) AUX POWER ( i R�)) REMOTE CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE' LISTING No. 3240-1004:108 Pagel ofl-* CATEGORY: Duct Smoke Detector Housing/Base LISTEE: Air Products and Controls Inc., 1749 East Highwood, Pontiac MI 48340 Contact: *Richard Steele (248) 332-3900 *FAX (248) 332-8807 Models SM -501-N and SM -501-P duct smoke detector units. Units consist of an enclosure, relay, electrical components, listed open area detector and sampling and exhausted tubes. All units are four -wire duct detectors. Suffix -N indicates the unit employs an ionization smoke detector head. Suffix -P indicates the unit employs a photoelectric smoke detector head. Refer to listee's data sheet for additional detailed product description and operational considerations. IRATING: 24 VAC, 24 VDC, 115 VAC or 230 VAC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as duct detectors for use with separately listed compatible fire alarm control units when installed in HVAC systems with air velocity between 500 and 4000 ft./min. "Rev. 05-28-2004 This listing Is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation V criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MARCH 21, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager Accessories System Sensor provides system Flexibility with a variety of accessories, including two remote test stations, and several different means of visible and audible system annunciation. As with our duct detectors, all duct smoke detector accessories are UL listed. Ordering Information Metal sampling tube duct widths i'-2' (03-0.6 m) a � S' l" Metal sampling tube duct widths 2-4'(0.6-1.2 m) i Metal sampling tube duct widths 4"-8" (12-2.4 m) ST_ 10 Metal sampling tube duct widths 8'-12"(24-3.7 m) { N Replacement telescoping sampling tube P48 -S5-00 Replacement end cap forT80-71-00 iq Multi -Signaling accessory RTS451 KEY Remote test station with key lock PA40OW RT5451 APA451 RTS451KEY Plezo Annunciator Remote Test Station (UL S401 1) with Key (UL 52522) Ordering Information Metal sampling tube duct widths i'-2' (03-0.6 m) Fk Metal sampling tube duct widths 2-4'(0.6-1.2 m) i Metal sampling tube duct widths 4"-8" (12-2.4 m) ST_ 10 Metal sampling tube duct widths 8'-12"(24-3.7 m) T80-71-00 Replacement telescoping sampling tube P48 -S5-00 Replacement end cap forT80-71-00 SSK451 Multi -Signaling accessory RTS451 KEY Remote test station with key lock PA40OW RT5451 .9ii Remote Test Station (UL 53593) � l4iifi si i414ig 4i! shown with P524LOW add-on strobe (PS12/24SLENSW smoke SSK451 Multi -Signaling Accessory (UL 268A) Ordering Information Fart no. it;escription DH100ACDCL1D 4 -wire photoelectric duct detector with low -Flow technology AS 190 Replacement 4 -wire photoelectric detector board A5064 Replacement 4 -wire power board Accessories ST -1.5 Metal sampling tube duct widths i'-2' (03-0.6 m) Fk Metal sampling tube duct widths 2-4'(0.6-1.2 m) i Metal sampling tube duct widths 4"-8" (12-2.4 m) ST_ 10 Metal sampling tube duct widths 8'-12"(24-3.7 m) T80-71-00 Replacement telescoping sampling tube P48 -S5-00 Replacement end cap forT80-71-00 SSK451 Multi -Signaling accessory RTS451 KEY Remote test station with key lock PA40OW RT5451 Mini -Alert Sounder Remote Test Station (UL 53593) (UL 52522) shown with P524LOW add-on strobe (PS12/24SLENSW smoke lens option available) Fart no. it;escription DH100ACDCL1D 4 -wire photoelectric duct detector with low -Flow technology AS 190 Replacement 4 -wire photoelectric detector board A5064 Replacement 4 -wire power board Accessories ST -1.5 Metal sampling tube duct widths i'-2' (03-0.6 m) ST -3 Metal sampling tube duct widths 2-4'(0.6-1.2 m) ST -5 Metal sampling tube duct widths 4"-8" (12-2.4 m) ST_ 10 Metal sampling tube duct widths 8'-12"(24-3.7 m) T80-71-00 Replacement telescoping sampling tube P48 -S5-00 Replacement end cap forT80-71-00 SSK451 Multi -Signaling accessory RTS451 KEY Remote test station with key lock RTS451 Remote test station APA451 Remote annunciator with piezo alarm RA40OZ Remote Annunciator (UL 52522) SSK451 Multi -Signaling Accessory (UL 268A) shown with PS24LOW add-on strobe (PS 1 2/24SLENSW smoke lens option available) MOD40OR Sensitivity test module RA40OZ Remote annunciator alarm LED F36-09-11 Replacement air filters (two per package) M02-04-00 Test magnet P48-21-00 End cap for metal sampling tubes 508-39-01 Photo replacement screen PA40OW Mini -Alert sounder PS24LOW Mini -Alert add-on strobe PS12/24SLENSW Wall-mount°SMOKE"lens PS12/24SLENSC Ceiling-mount"SMOKE"lens .SYSTEM oM6n1mSe SENSOR � s� 3825 Ohio Avenue • St. Charles, IL 60174 � ma,,,,p r„� wvc : fm Phone: 800-SENSOR2 • Fax: 630-377-6495 0—t W°a"`"f—"°"""' dgd""` "'°"°r[1daa h m AOS -1044-007-710641676 Selectable Output Horns, Strobes, and Horn/Strobes SpectrAlert' Advance selectable -output horns, strobes, and homistrobes are rich with features guaranteed to cut installation times and maximize profits. The SpectrAlert Advance series of notification appliances is designed to simplify installations, with features such as plug in designs, instant feedback messages to ensure correct Installation of individual devices, and 11 field -selectable candela settings for wall and ceiling strobes and horn/strobes. When installing Advance products, first attach a universal mounting plate to a four -inch square, four -inch octagon or double -gang junction box. The two -wire mounting plate attaches to a single -gang junction box. Next, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn, strobe or horn/strobe to the mounting plate by inserting the product's tabs in the mounting plate's grooves. The device will rotate into position, locking the product's pins into the mounting plate's terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. The SpectrAlert Advance series includes outdoor notification appliances. Outdoor strobes and horn/strobes (two wire and four wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. fr o S s t o m Se n s o r Features Electrically compatible with existing SpectrAlert products • Automatic selection of 12- or 24 -volt operation at 15 and 15/75 candela Plug-in design Field selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185 Same mounting plate for wall- and ceiling -mount units Shorting spring on mounting plate for continuity check before installation •Tamper resistant construction Outdoor wall and ceiling products rated from —40°F to 151°F • Design allows minimal intrusion into the back box Horn rated at 88+ dbA at 16 volts • Rotary switch for horn tone and three volume selections Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) outdoor requirements Outdoor products rainproof per UL 50 (NEMA 3R) • Compatible with MDL sync module Agency Listings SIGNALNIG `. EA 71251653:186 (indoor svobes) 7305-1653:87astro6es) ■ :, e8 s ft«Wnrstrobes. 7125-16531 approved chimeAtrobes) LISTED APPROVED 71351653:189(h—,chimes) S-1011 55512 5359; 3023572 MEA4S205-E SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes and horn/strobes shall mount to a standard 4 x 4 x 1'h -inch back box, 4 -inch octagon back box or double --gang back box.Two-wire products shall also mount to a single -gang 2 x 4 x 1 7/e -inch back box A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync -Circuit' Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync -Circuit Module, 12 -volt rated notification appliance circuit outputs shall operate between nine and 175 volts; 24 -volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full -wave rectified, unfiltered power supply. Strobes and horn/strobes shall have field -selectable candela settings including 15,15/75, 30, 75,95, 1 IQ 115,135,150,177,185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at I Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three -pattern and a non temporal (continuous) pattern. These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn on horn/strobe models shall operate on a coded or non -coded power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit.The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync -Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires.The module shall mount to a 4"/16 x 4"/16 x 21/8 -inch back box. The module shall also control two StyleY (class B) circuits or one Style Z (class A) circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 4900 K Series Operating Temperature -40°F to 151 °F (-40°C to WC) Humidity Range 10 to 93°x6 non -condensing (indoor products) Strobe Flash Rate i flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR' Operating Voltage Rangel 8 to 175 V (I 2V nominal) or 16 to 33 V (24 nominal) input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions (including lens) 6.8- diameter x 2.5"high (173 mm diameter x 64 mm high) Wall mount dimensions (including lens) 5.61 x 4.7V x 2.5"D (142 mm L x 119 mm W x 64 mm D) Horn dimensions 5.61 x 4.7V x 13"D (142 mm L x 119 mm W x 33 mm D) Wall -mount back box skirt dimensions (BBS -2, BBSW 2) 5.91L x 5.0"W x 2.2D (151 mm L x 128 mm W x 56 mm D) Ceiling -mount back box skirt dimensions (BBSC-2, BBSCW 2) 7.1 "diameter x 2.25" high (180 mm diameter x 57 mm high) Wall -mount weatherproof back box dimensions (SA-WBB) 5.71 x 5.1'W x 201D (145 mm L x 130 mm W x 51 mm D) Ceiling -mount weatherproof back box dimensions (SA-WBBC) 7.1 -diameter x 2.0"high (180 mm diameter x 51 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AOs-0395-003 UL Current Draw Data UL Max. Horn Current Draw (mA RMS) 8-17.5 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal Candela 8-17.5 Volts DC FWR 16-33 DC Volts FWR Standard 15* 123 128 66 71 Candela Range 15/75* 142 148 77 81 48 30* NA NA 94 96 75 75* NA NA 158 153 69 95* NA NA 181 176 50 110 NA NA 202 195 75 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 79 177 NA NA 281 251 UL Max. Horn Current Draw (mA RMS) 8-17.5 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non -temporal High 57 56 69 75 Non -temporal Medium 42 50 60 69 Non -temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 185 NA NA 286 258 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 ]is Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non -temporal High 141 152 91 100 116 176 201 221 229 Non -temporal Medium 133 145 75 85 102 163 187 207 216 Non -temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non -temporal High 142 161 103 112 126 181 203 221 229 Non -temporal Medium 134 155 85 95 110 166 189 208 216 Non -temporal Low 132 154 80 90 105 161 184 202 211 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non -temporal High 255 270 303 309 Non -temporal High 233 248 275 281 Non -temporal Medium 242 259 293 299 Non -temporal Medium 219 232 262 267 Non -temporal Low 238 254 291 295 Non -temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed candela r _ , - • - , ratings must be reduced in accordance with this table. 0614 Strob�Outpu��d) 8-17.5 16-33 24 VolYNominal Switch Volts Volts Reverberant Anechoic Listed Candela Candela rating at -40°F Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 15 1 Temporal High 78 78 84 84 88 88 99 98 15/75 Do not use below 32°F 2 Temporal Medium 74 74 80 80 86 86 96 96 30 3 Temporal Low 71 73 76 76 83 80 94 89 75 44 4 Nori-temporal High 82 82 88 88 93 92 100 100 95 70 5 Non -temporal Medium 78 78 85 85 90 90 98 98 110 110 6 Non -temporal Low 75 75 81 81 88 84 96 92 115 115 7r Coded High 82 82 88 88 93 92 101 101 135 135 8r Coded Medium 78 78 85 85 90 90 97 98 150 150 9r Coded Low 75 75 81 81 88 85 96 92 177 1177 'Settings 7, 8, and 9 are not available on 2 -wire horn/strobe. 185 1185 A05 -0395 -OM Wert Advance Dimensions Ceiling -mount horn/strobes 5.05" 2.23 7.1" �2-� 2.0" Dia --� as y � O o � 2.0" O O P O a� 5.98- ® 5.7- ° o 0 o 0 0 O a o �0 o� Wall back box skirt Ceiling back box skirt Wall weatherproof back box Ceiling weatherproof back box SpectrAlert Advance Ordering Information DescriptionModel Description Model Wall Horn/Strobes Ceiling Horn/Strobes (contd.) P2R*t 2 -wire Horn/Strobe, Standard cd% Red PC2W*t 2 -wire Horn/Strobe, Standard cd, White P2RH* 2 -wire Horn/Strobe, High cd, Red PC2WH*t 2 -wire Horn/Strobe, High cd, White P2RK* 2 -wire Horn/Strobe, Standard cd, Red, Outdoor PC4R 4 -wire Horn/Strobe, Standard cd, Red P2RHK* 2 -wire Horn/Strobe, High cd, Red, Outdoor PC4RH 4 -wire Horn/Strobe, High cd, Red P2W* 2 -wire Horn/Strobe, Standard cd, White PC4RK 4 -wire Horn/Strobe, Standard cd, Red, Outdoor P2WH* 2 -wire Horn/Strobe, High cd, White PC4RHK 4 -wire Horn/Strobe, High cd, Red, Outdoor P4R* 4 -wire Horn/Strobe, Standard cd, Red PC4W 4 -wire Horn/Strobe, Standard cd, White P4RH* 4 -wire Horn/Strobe, High cd, Red PC4WH 4 -wire Horn/Strobe, High cd, White P4RK 4 -wire Horn/Strobe, Standard cd, Red, Outdoor Ceiling Strobes P4RHK 4 -wire Horn/Strobe, High cd, Red, Outdoor SCR* Strobe, Standard cd, Red P4W* 4 -wire Horn/Strobe, Standard cd, White SCRH* Strobe, High cd, Red P4WH* 4 -wire Horn/Strobe, High cd, White SCRK Strobe, Standard cd, Red, Outdoor Wall Strobes SCRHK Strobe, High cd, Red, Outdoor SR*' Strobe, Standard cd, Red SCW*t Strobe, Standard cd, White SRH*t Strobe, High cd, Red SCWH*t Strobe, High cd, White SRK Strobe, Standard cd, Red, Outdoor Horns SRHK Strobe, High cd, Red, Outdoor HR Horn, Red SW* Strobe, Standard cd, White HRK Horn, Red, Outdoor SWH* Strobe, High cd, White HW Horn, White Ceiling Horn/Strobes Accessories PC2R* 2 -wire Horn/Strobe, Standard cd, Red BBS -2 Back Box Skirt, Wall, Red PC2RH* 2 -wire Horn/Strobe, High cd, Red BBSW-2 Back Box Skirt, Wall, White PC2RK 2 -wire Horn/Strobe, Standard cd, Red, Outdoor BBSC-2 Back Box Skirt, Ceiling, Red PC2RHK 2 -wire Horn/Strobe, High cd, Red, Outdoor BBSCW-2 Back Box Skirt, Ceiling, White Notes: * Add'-P'to model number for plain housing (no'FIRE'marking on cover), e.g., P2R-P t Add'-SP'to model number for"FUEGO'marking on cover, e.g, P2R-SP *'Standard cd, refers to strobes that include 15,15/75, 30,75,95, 11 Q and 115 candela settings.'High cd"refers to strobes that include 135, 150, 177, and 185 candela settings. All outdoor units ending in IC include a weatherproof back box. O,F- SYSTE/i/I 02" Syne. 5e . �Cw �C'oR. hon Ohio Avenue • St. Charles, 377-649 a�a.-tp d ttoadudVt,an e.vhe .dthM& O« t fa L�VJ Phone: 800SENSOR2•Fax:6303776495 ""tom°'"r0ndS-03"d"°3.12106-#1676°"�r""a�m�ee` A05-0395-003.12/06.11676 LISTING No. CATEGORY: LISTEE: DESIGN: TING: NSTALLATION: RKING: PPROVAL: i This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation V criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 8.9 2007 Listing Expires .lune 30, 2088 Authorized By. MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE Of THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7125-1653:186 Page 1 of 1 Fire Alarm Devices for the Hearing Impaired System Sensor, Unincorporated Div. of Honeywell Int'I Inc., 3825 Ohio Avenue, St, Charles IL 60174 Contact: Trish Linhart (630) 377-6580 ext. 1185 FAX (630) 377-7245 Models SR, SRH, SW and SWH strobes followed by the suffix —P, or none, synchronous type. Models SCR, SCRH, SCW and SCWH strobes followed by the suffix P, SP, -SP, -PG or none, synchronous type. Intended for indoor use mounted on the wall or the ceiling. Refer to listee's data sheet for additional detailed product description and operational considerations. H prefix models: 16-33 VDC/FWR Without H prefix: 8 —17.5 or 16-33 VDC/FWR In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as strobe lights suitable for hearing impaired application when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Refer to listee's Installation Instruction Manual for details. 1-06-2006 jew LISTING No. CATEGORY: LISTEE: TING: ALLATION: NG: AL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7135-1653:147 Page 1 of 9 Audible Devices System Sensor, Unincorporated Div. of Honeywell Intl Inc., 3825 Ohio Avenue, St Charles IL 60174 Contact: Trish Emhart (630) 377-6580 ext. 1185 FAX (630) 377-7245 Models "SpecfrAlert" PC2415, PC2415W, PC241575, PC241575W, PC2430, PC2430W, PC2460, PC2460W, PC2475, PC2475W, PC2495, PC2495W, PC241151 PC24115W, PC24177 and PC24177W horn/strobes. Unit may have suffix -P for plain plastic housing. Models P2475 horn/strobes with colored lens. Units may have suffix RLP, ALP, GLP or BLP and may or may not be followed by W. The suffix —P for plain plastic housing. These models are for private mode signaling use. Refer to listee's data sheet for additional detailed product description and operational considerations. Electrical: 16-33 VDC, P2475:20-30 VDC Candela: -15: 15cd -1575: 15ed, 75c d on axis -30: 30cd -60: 60cd -75: 75cd -95: 95cd -115: 115cd -177: 177cd In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. These sounder/strobe combination units are not intended for field assembly. Listee's name, model number, rating and UL label. Listed as horn strobes for use with separately listed compatible fire alarm control units. Suitable for hearing impaired application: PC series are suitable for wall or ceiling mount. For indoor use only. Units can generate the distinctive three -pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to manufacturer's Installation Manual for details. Formerly 7135-1209:204 M20-05 This fisting is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent veriftcation of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: Authorized By. JUNE 8, 2007 Listing Expires June 30, 2008 MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager