Loading...
HomeMy WebLinkAboutB06-2812 CF Overhead Sprinkler Hydro TestCONTRACTOR'S MATERIAL & TEST CERTIFICATE FOR ABOVEGROUND PIPING Factory Additional copies of this form are Loss Prevention Publications - Training Resource Center Mutual System available to insured from: Factory Mutual Engineering and Research, 1151 Boston -Providence Turnpike, P.O. Box 9102, Norwood MA 02062 PROCEDURE: Upon completion of work, inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall be corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners and contractor. It is understood the owner's representatives signature in no way prejudices any claim against the contractor for faulty material, poor workmanship, or failure to comply with Rproving authority's requirements or local ordinances. PROPERTY NAME: Setzer Forest Products TJOB# 06194 DATE: 12/14/06 PROPERTY ADDRESS: 1980 Kusel Road — Oroville, Ca. 95966 ACCEPTED BY APPROVING AUTHORITY'(S) NAMES: Butte County Fire District ADDRESS: 176 Nelson Ave. — Oroville, Ca. 95965 PLANS INSTALLATION CONFORMS TO ACCEPTED PLANS YES X NO EQUIPMENT USED 1S APPROVED (IF NO, STATE DEVIATIONS BELOW) YES X NO HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO LOCATIONOW CONTROL AND VALVES THE CARKAND MAINTENANCE OF THIS NEW EQUIPMENT? YES X NO INSTRUCTIONS IF NO, EXPLAIN: HAVE COPIES OF APPROPRIATE INSTRUCTIONS AND CARE AND MAINTENANCE CHARTS BEEN LEFT ON YES X TNO PREMISES? IF NO, EXPLAIN: LOCATION OF SUPPLIES BUILDINGS SYSTEM Entire Building MAKE MODEL YEAR OF ORIFICE SIZE QUANTITY TEMPERATURE TYCO MANUFACTURE RATING Upright TY -B 2006 3/4'? 60 2860 SPRINKLERS PIPE CONFORMS TO NFPA #13 STANDARD YES X NO PIPE &FITTINGS FITTINGS CONFORM TO NFPA # 13 STANDARD YES X NO ALARM DEVICE MAXIMUM TIME TO OPERATE THROUGH TEST PIPE ALARM VALVE OR TYPE MAKE MODEL MIN. SEC. FLOW WATERFLOW POTTER VSR-F 0 60 - INDICATOR SWITCH DRY VALVE Q.O.D. MAKE MODEL SERIAL NO. MAKE MODEL SERIAL NO. DRY PIPE OPERATING TIME TO TRIP WATER AIR TRIP POINT TIME WATER ALARM OPER- TEST THRU TEST PRESSURE PRESSURE AIR PRESSURE REACHED OUT. ATED PROPERLY PIPE MIN. SEC. PSI PSI PSI MIN. SEC. MIN. SEC. WITHOUT Q.O.D. WITH Q.O.D. IF NO, EXPLAIN: OPERATION I PNEUMATIC ELECTRIC I HYDRAULIC PIPING SUPERVISED YES NO DETECTING MEDIA YES NO SUPERVISED? ' DELUGE AND DOES THE VALVE OPERATE FROM THE MANUAL TRIP AND/OR REMOTE CONTROL? YES NO PREACTION IS THERE AN ACCESSIBLE FACILITY IN EACH CIRCUIT FOR TESTING? YES NO VALVES IF NO, EXPLAIN: DOES EACH CIRCUIT OPERATE DOES EACH CIRCUIT MAXIMUM TIME TO MAKE MODEL SUPERVISION LOSS ALARM? OPERATE VALVE RELEASE. OPERATE RELEASE YES NO YES NO MIN. SEC. HYDROSTATIC: HYDROSTATIC TESTS SHALL BE MADE AT NOT LESS THAN 200 PSI (13.6 BARS) ABOVE STATIC PRESSURE IN EXCESS OF 150 PSI (10.3 BARS) FOR TWO HOURS. DIFFERENTIAL DRY - TEST DESCRIPTION PIPE VALVE CLAPPERS SHALL BE LEFT OPEN DURING TEST TO PREVENT DAMAGE. ALL ABOVE -GROUND PIPING LEAKAGE SHALL BE STOPPED. PNEUMATIC: ESTABLISH 40 PSI (2.7 BARS) AIR PRESSURE AND MEASURE DROP WHICH SHALL NOT EXCEED 1-1 /2 PSI (0.1 BARS) IN PRESSURE TANKS AT NORMAL WATER LEVEL AND AIR PRESSURE AND MEASURE AIR PRESSURE DROP WHICH SHALL NOT EXCEED 1- 1/2 PSI (0.1 BARS) IN 24 HRS. ALL PIPING HYDROSTATICALLY TE'ST'ED AT 200 PSI FOR 2 HRS. IF NO, STATE REASON: DRY PIPING PNEUMATICALLY TESTED? YES NO EQUIPMENT OPERATES PROPERLY? YES NO DRAIN READING OF GAGE LOCATED NEAR WATER SUPPLY TEST RESIDUAL PRESSURE WITH VALVE IN TESTS PIPE. TEST 200 PSI TEST PIPE OPEN WIDE 200 PSI UNDERGROUND MAINS AND LEAD-IN CONNECTIONS TO SYSTEM RISERS SHALL BE FLUSHED BEFORE CONNECTION MADE TO SPRINKLER PIPING. VERIFIED BY COPY OF THE FORM # 85B? YES NO OTHER EXPLAIN FLUSHED BY INSTALLER OF UNDERGROUND YES NO SPRINKLER PIPING? BLANK'TESTING NUMBER USED LOCATIONS NUMBER REMOVED GASKETS WELDED PIPING? X YES -7- NO IF YES... DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING YES X NO PROCEDURES COMPLY WITH THE REQUIREMENTS OF AT LEAST AWS D10.9, LEVEL AR -3? WELDING DO YOU CERTIFY THAT THE WELDING WAS PERFORMED BY WELDERS QUALIFIED YES X NO IN COMPLIANCE WITH THE REQUIREMENTS OF AT LEAST AWS DI 0.9. LEVEL AR -3? DO YOU CERTIFY THAT WELDING WAS CARRIED OUT IN COMPLIANCE WITH A YES X NO DOCUMENTED QUALITY CONTROL PROCEDURE TO INSURE THAT ALL DISCS ARE RETRIEVED, THAT OPENINGS IN PIPING ARE SMOOTH, THAT SLAG AND OTHER WELDING RESIDUE ARE REMOVED, AND THAT INTERNAL DIAMETERS OF PIPING ARE NOT PENETRATED? HYDRAULIC DATA NAMEPLATE NAMEPLATE PROVIDED? YES IF NO, EXPLAIN: X NO DATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN: REMARKS NAME OF INSTALLING CONTRACTOR: CEN -CAL FIRE SYSTEMS, INC. TESTS WITNESSED BY FOR AUTIVIIITY HAVING JUR DICTIO Signed) ITL DATE SIGNATURES `j" -20 •-� FO I LI RACTOR (Signed) TIT E U DATE ys• � e- - e c> --- - C; .� ADDITIONAL EXPLAIXTION AND NOTES: