HomeMy WebLinkAboutDocsCH_1979226-FLGWATERNovember 11, 2019
Micheal Dunn Lab ID : CH 1979226
2803 Eskin Maidu Trail
Chico, CA 95928
Customer : 7-2229
Laboratory Report
This Page is to be Stamped
Introduction: This report package contains total of 9 pages divided into 4 sections:
Case Narrative (2 pages) : An overview of the work performed at FGL.
Sample Results (2 pages) : Results for each sample submitted.
Interpretation (1 page) : Drinking Water Interpretation for each sample submitted.
Quality Control (4 pages) : Supporting Quality Control (QC) results.
Case Narrative
This Case Narrative pertains to the following samples:
Sample Description Date
Sampled
Date
Received FGL Lab ID # Matrix
Well Head 10/11/2019 10/11/2019 CH 1979226-001 DW
Sampling and Receipt Information: All samples were received in acceptable condition and within
temperature requirements, unless noted on the Condition Upon Receipt (CUR) form. All samples arrived
on ice. All samples were prepared and analyzed within the method specified hold time. All samples were
checked for pH if acid or base preservation is required (except for VOAs). For details of sample receipt
information, please see the attached Chain of Custody and Condition Upon Receipt Form.
Quality Control: All samples were prepared and analyzed according to the following tables:
Inorganic - Metals QC
200.8 11/06/2019:217491 All analysis quality controls are within established criteria
11/06/2019:212794 All preparation quality controls are within established criteria
245.1 11/05/2019:217300 All analysis quality controls are within established criteria
11/05/2019:212722 All preparation quality controls are within established criteria
Organic QC
524.2 10/17/2019:216431 All analysis quality controls are within established criteria
10/16/2019:212132 All preparation quality controls are within established criteria
Corporate Offices & Laboratory853 Corporation StreetSanta Paula, CA 93060TEL: (805)392-2000Env FAX: (805)525-4172 / Ag FAX: (805)392-2063CA ELAP Certification No. 1573
Office & Laboratory2500 Stagecoach RoadStockton, CA 95215TEL: (209)942-0182FAX: (209)942-0423CA ELAP Certification No. 1563
Office & Laboratory
563 E. Lindo AvenueChico, CA 95926TEL: (530)343-5818
FAX: (530)343-3807CA ELAP Certification No. 2670
Office & Laboratory9415 W. Goshen AvenueVisalia, CA 93291
TEL: (559)734-9473FAX: (559)734-8435CA ELAP Certification No. 2810
Office & Laboratory
3442 Empresa Drive, Suite DSan Luis Obispo, CA 93401TEL: (805)783-2940
FAX: (805)783-2912CA ELAP Certification No. 2775
ENVIRONMENTAL AGRICULTURAL
Analytical Chemists
November 11, 2019 Lab ID : CH 1979226
Micheal Dunn Customer : 7-2229
Certification:: I certify that this data package is in compliance with ELAP standards, both technically
and for completeness, except for any conditions listed above. Release of the data contained in this data
package is authorized by the Laboratory Director or his designee, as verified by the following electronic
signature.
KD:SBDigitial Signature Stamp Y = 03.1
Approved By Kelly A. Dunnahoo, B.S. Digitally signed by Kelly A. Dunnahoo, B.S.Title: Laboratory Director
Date: 2019-11-11
November 11, 2019 Lab ID : CH 1979226-001
Customer ID : 7-2229
Micheal Dunn
Sampled On : October 11, 2019-15:45
Sampled By : Corey Gwathney
Received On : October 11, 2019-16:30
2803 Eskin Maidu Trail
Chico, CA 95928
Matrix : Drinking Water
Description : Well Head
Project : 2803 Eskin Maidu Trail, Chico, CA 95928
This Page is to be Stamped
Sample Result - Inorganic
Sample Preparation Sample Analysis Constituent Result PQL Units MCL/AL
Method Date/ID Method Date/ID
Metals, Total
Aluminum ND 10 ug/L 1000 200.8 11/06/19:212794 200.8 11/06/19:217491
Antimony ND 1 ug/L 6 200.8 11/06/19:212794 200.8 11/06/19:217491
Arsenic 11 1 ug/L 10 200.8 11/06/19:212794 200.8 11/06/19:217491
Barium 52.1 0.2 ug/L 1000 200.8 11/06/19:212794 200.8 11/06/19:217491
Beryllium ND 1 ug/L 4 200.8 11/06/19:212794 200.8 11/06/19:217491
Cadmium ND 0.2 ug/L 5 200.8 11/06/19:212794 200.8 11/06/19:217491
Chromium 1 1 ug/L 50 200.8 11/06/19:212794 200.8 11/06/19:217491
Lead 3.1 0.5 ug/L 15 200.8 11/06/19:212794 200.8 11/06/19:217491
Mercury ND 0.02 ug/L 2 245.1 11/05/19:212722 245.1 11/05/19:217300
Nickel ND 1 ug/L 100 200.8 11/06/19:212794 200.8 11/06/19:217491
Selenium ND 1 ug/L 50 200.8 11/06/19:212794 200.8 11/06/19:217491
Silver ND 1 ug/L 1002 200.8 11/06/19:212794 200.8 11/06/19:217491
Thallium ND 0.2 ug/L 2 200.8 11/06/19:212794 200.8 11/06/19:217491
Vanadium 9 2 ug/L 200.8 11/06/19:212794 200.8 11/06/19:217491
ND=Non-Detected. PQL=Practical Quantitation Limit. * PQL adjusted for dilution.
MCL = Maximum Contamination Level. 2 - Secondary Standard. 3 - CDPH Notification Level. AL = Regulatory Action Level.
Corporate Offices & Laboratory853 Corporation StreetSanta Paula, CA 93060TEL: (805)392-2000Env FAX: (805)525-4172 / Ag FAX: (805)392-2063CA ELAP Certification No. 1573
Office & Laboratory2500 Stagecoach RoadStockton, CA 95215TEL: (209)942-0182FAX: (209)942-0423CA ELAP Certification No. 1563
Office & Laboratory
563 E. Lindo AvenueChico, CA 95926TEL: (530)343-5818
FAX: (530)343-3807CA ELAP Certification No. 2670
Office & Laboratory9415 W. Goshen AvenueVisalia, CA 93291
TEL: (559)734-9473FAX: (559)734-8435CA ELAP Certification No. 2810
Office & Laboratory
3442 Empresa Drive, Suite DSan Luis Obispo, CA 93401TEL: (805)783-2940
FAX: (805)783-2912CA ELAP Certification No. 2775
ENVIRONMENTAL AGRICULTURAL
Analytical Chemists
November 11, 2019 Lab ID : CH 1979226-001
Customer ID : 7-2229
Micheal Dunn
Sampled On : October 11, 2019-15:45
Sampled By : Corey Gwathney
Received On : October 11, 2019-16:30
2803 Eskin Maidu Trail
Chico, CA 95928
Matrix : Drinking Water
Description : Well Head
Project : 2803 Eskin Maidu Trail, Chico, CA 95928
This Page is to be Stamped
Sample Result - Organic
Sample Preparation Sample Analysis Constituent Result PQL Units MCL/AL
Method Date/ID Method Date/ID
EPA 524.2
4-Bromofluorobenzene‡ 98.8 70-130 % 524.2 10/16/19:212132 524.2 10/17/19:216431
1,2-Dichlorobenzene-d4‡ 94.1 70-130 % 524.2 10/16/19:212132 524.2 10/17/19:216431
Benzene ND 0.5 ug/L 1 524.2 10/16/19:212132 524.2 10/17/19:216431
ND=Non-Detected. PQL=Practical Quantitation Limit. ‡Surrogate. * PQL adjusted for dilution.
MCL = Maximum Contamination Level. 2 - Secondary Standard. 3 - CDPH Notification Level. AL = Regulatory Action Level.
Corporate Offices & Laboratory853 Corporation StreetSanta Paula, CA 93060TEL: (805)392-2000Env FAX: (805)525-4172 / Ag FAX: (805)392-2063CA ELAP Certification No. 1573
Office & Laboratory2500 Stagecoach RoadStockton, CA 95215TEL: (209)942-0182FAX: (209)942-0423CA ELAP Certification No. 1563
Office & Laboratory
563 E. Lindo AvenueChico, CA 95926TEL: (530)343-5818
FAX: (530)343-3807CA ELAP Certification No. 2670
Office & Laboratory9415 W. Goshen AvenueVisalia, CA 93291
TEL: (559)734-9473FAX: (559)734-8435CA ELAP Certification No. 2810
Office & Laboratory
3442 Empresa Drive, Suite DSan Luis Obispo, CA 93401TEL: (805)783-2940
FAX: (805)783-2912CA ELAP Certification No. 2775
ENVIRONMENTAL AGRICULTURAL
Analytical Chemists
November 11, 2019 Lab ID :CH 1979226-001
Micheal Dunn Description : Well Head
Drinking Water Interpretation
Summary: Your water has a failure for one or more items on this sample report. Please see
the table below to determine which items failed. Following the table is a brief
explanation describing the significance of the failure and whether treatment may
be required.
MCL
CONSTITUENT RESULT UNITS MCL LESS OR
EQUAL EXCEED
Inorganic - Primary
Aluminum ND ug/L 1000 Pass
Antimony ND ug/L 6 Pass
Arsenic 11 ug/L 10 Fail
Barium 52.1 ug/L 1000 Pass
Beryllium ND ug/L 4 Pass
Cadmium ND ug/L 5 Pass
Chromium 1 ug/L 50 Pass
Mercury ND ug/L 2 Pass
Nickel ND ug/L 100 Pass
Selenium ND ug/L 50 Pass
Thallium ND ug/L 2 Pass
Inorganic - Secondary
Aluminum ND ug/L 200 Pass
Silver ND ug/L 100 Pass
Organic - Primary
Benzene ND ug/L 1 Pass
Other
Lead 3.1 ug/L 15** Pass
ND=Non-Detected. ** California Title 22, Section 64672.3
November 11, 2019 Lab ID :CH 1979226-001
Micheal Dunn Description : Well Head
Drinking Water Interpretation
MCL: The maximum level at which a constituent may be present and be considered
acceptable for potability or aesthetics.
Primary: Items listed as primary are regulated because of health concerns. If there is a
failure for a primary constituent treatment is normally required.
Secondary: Items listed as secondary are regulated because they may adversely affect the
taste, odor or appearance of drinking water. They are not directly health related.
If there is a failure for a secondary constituent on a small public water system it is
best to consult your regulator to determine if treatment is required. A secondary
constituent failure for a private water system does not require treatment.
However, the owner may wish to treat the water in order to improve the quality.
Treatment: If your water requires treatment we suggest that you contact a qualified water
treatment company. They are normally listed in the yellow pages under the
following topics:
Water Purification & Filtration Equipment
Water Softening & Conditioning Equipment
Water Treatment Equipment
Health Effects Language
Arsenic Some people who drink water containing arsenic in excess of the MCL over many years could experience
skin damage or problems with their circulatory system, and may have an increased risk of getting cancer.
This Page is to be Stamped
November 11, 2019 Lab ID : CH 1979226
Micheal Dunn Customer : 7-2229
Quality Control - Organic
Constituent Method Date/ID Type Units Conc. QC Data DQO Note
Organic
1,2-Dichlorobenzene-d4 524.2 10/16/19:212132VRG Blank ug/L 10.00 93.7 % 70-130
MS ug/L 10.00 103 % 70-130
(SP 1900475-045) MSD ug/L 10.00 99.1 % 70-130
MSRPD ug/L 10.00 3.5% ≤20
524.2 10/17/19:216431VRG CCV ug/L 10.04 95.3 % 70-130
4-Bromofluorobenzene 524.2 10/16/19:212132VRG Blank ug/L 10.00 98.3 % 70-130
MS ug/L 10.00 99.1 % 70-130
(SP 1900475-045) MSD ug/L 10.00 97.9 % 70-130
MSRPD ug/L 10.00 1.2% ≤30
4-Bromofluorobenzene (BFB) 524.2 10/17/19:216431VRG CCV ug/L 10.05 96.2 % 70-130
Benzene 524.2 10/16/19:212132VRG Blank ug/L ND <0.5
MS ug/L 10.00 101 % 12-158
(SP 1900475-045) MSD ug/L 10.00 89.7 % 12-158
MSRPD ug/L 10.00 11.7% ≤36
524.2 10/17/19:216431VRG CCV ug/L 10.00 83.1 % 70-130
Definition
CCV : Continuing Calibration Verification - Analyzed to verify the instrument calibration is within criteria.
Blank : Method Blank - Prepared to verify that the preparation process is not contributing contamination to the samples.
MS : Matrix Spikes - A random sample is spiked with a known amount of analyte. The recoveries are an indication of how that sample
matrix affects analyte recovery.
MSD : Matrix Spike Duplicate of MS/MSD pair - A random sample duplicate is spiked with a known amount of analyte. The recoveries
are an indication of how that sample matrix affects analyte recovery.
MSRPD : MS/MSD Relative Percent Difference (RPD) - The MS relative percent difference is an indication of precision for the preparation
and analysis.
ND : Non-detect - Result was below the DQO listed for the analyte.
DQO : Data Quality Objective - This is the criteria against which the quality control data is compared.
Corporate Offices & Laboratory853 Corporation StreetSanta Paula, CA 93060TEL: (805)392-2000Env FAX: (805)525-4172 / Ag FAX: (805)392-2063CA ELAP Certification No. 1573
Office & Laboratory2500 Stagecoach RoadStockton, CA 95215TEL: (209)942-0182FAX: (209)942-0423CA ELAP Certification No. 1563
Office & Laboratory
563 E. Lindo AvenueChico, CA 95926TEL: (530)343-5818
FAX: (530)343-3807CA ELAP Certification No. 2670
Office & Laboratory9415 W. Goshen AvenueVisalia, CA 93291
TEL: (559)734-9473FAX: (559)734-8435CA ELAP Certification No. 2810
Office & Laboratory
3442 Empresa Drive, Suite DSan Luis Obispo, CA 93401TEL: (805)783-2940
FAX: (805)783-2912CA ELAP Certification No. 2775
ENVIRONMENTAL AGRICULTURAL
Analytical Chemists
November 11, 2019 Lab ID : CH 1979226
Micheal Dunn Customer : 7-2229
Quality Control - Inorganic
Constituent Method Date/ID Type Units Conc. QC Data DQO Note
Metals
Aluminum 200.8 MS ug/L 5.000 109 % 75-125
(CH 1979226-001) MSD ug/L 5.000 115 % 75-125
MSRPD ug/L 5.000 0.29 ≤10
200.8 11/06/19:217491AC ICV ppb 50.00 99.9 % 90-110
ICB ppb 0.09 10
CCV ppb 50.00 105 % 90-110
CCB ppb 0.4 10
Antimony 200.8 MS ug/L 5.000 108 % 75-125
(CH 1979226-001) MSD ug/L 5.000 112 % 75-125
MSRPD ug/L 5.000 3.5% ≤20
200.8 11/06/19:217491AC ICV ppb 50.00 97.5 % 90-110
ICB ppb 0.12 1
CCV ppb 50.00 99.8 % 90-110
CCB ppb 0.03 1
Arsenic 200.8 MS ug/L 5.000 116 % 75-125
(CH 1979226-001) MSD ug/L 5.000 116 % 75-125
MSRPD ug/L 5.000 0.06% ≤20
200.8 11/06/19:217491AC ICV ppb 50.00 99.2 % 90-110
ICB ppb 0.01 1
CCV ppb 50.00 100 % 90-110
CCB ppb 0.003 1
Barium 200.8 MS ug/L 5.000 117 % 75-125
(CH 1979226-001) MSD ug/L 5.000 115 % 75-125
MSRPD ug/L 5.000 0.1% ≤20
200.8 11/06/19:217491AC ICV ppb 50.00 99.0 % 90-110
ICB ppb 0.008 0.2
CCV ppb 50.00 99.3 % 90-110
CCB ppb 0.022 0.2
Beryllium 200.8 MS ug/L 5.000 105 % 75-125
(CH 1979226-001) MSD ug/L 5.000 108 % 75-125
MSRPD ug/L 5.000 2.3% ≤20
200.8 11/06/19:217491AC ICV ppb 50.00 97.8 % 90-110
ICB ppb 0.028 0.2
CCV ppb 50.00 98.1 % 90-110
CCB ppb 0.007 0.2
Cadmium 200.8 MS ug/L 5.000 106 % 75-125
(CH 1979226-001) MSD ug/L 5.000 110 % 75-125
MSRPD ug/L 5.000 4.2% ≤20
200.8 11/06/19:217491AC ICV ppb 50.00 98.5 % 90-110
ICB ppb 0.001 0.2
CCV ppb 50.00 98.5 % 90-110
CCB ppb 0.001 0.2
Chromium 200.8 MS ug/L 5.000 107 % 75-125
(CH 1979226-001) MSD ug/L 5.000 107 % 75-125
MSRPD ug/L 5.000 0.6% ≤20
200.8 11/06/19:217491AC ICV ppb 50.00 99.3 % 90-110
ICB ppb -0.02 1
CCV ppb 50.00 101 % 90-110
CCB ppb -0.04 1
Lead 200.8 MS ug/L 5.000 105 % 75-125
(CH 1979226-001) MSD ug/L 5.000 109 % 75-125
MSRPD ug/L 5.000 2.4% ≤20
200.8 11/06/19:217491AC ICV ppb 50.00 98.0 % 90-110
ICB ppb 0.003 0.5
CCV ppb 50.00 97.8 % 90-110
November 11, 2019 Lab ID : CH 1979226
Micheal Dunn Customer : 7-2229
Quality Control - Inorganic
Constituent Method Date/ID Type Units Conc. QC Data DQO Note
Metals
Lead 200.8 11/06/19:217491AC CCB ppb -0.001 0.5
Nickel 200.8 MS ug/L 5.000 105 % 75-125
(CH 1979226-001) MSD ug/L 5.000 106 % 75-125
MSRPD ug/L 5.000 0.5% ≤20
200.8 11/06/19:217491AC ICV ppb 50.00 98.6 % 90-110
ICB ppb -0.13 1
CCV ppb 50.00 97.0 % 90-110
CCB ppb -0.14 1
Selenium 200.8 MS ug/L 5.000 117 % 75-125
(CH 1979226-001) MSD ug/L 5.000 121 % 75-125
MSRPD ug/L 5.000 2.8% ≤20
200.8 11/06/19:217491AC ICV ppb 50.00 105 % 90-110
ICB ppb 0.04 1
CCV ppb 50.00 106 % 90-110
CCB ppb 0.02 1
Silver 200.8 MS ug/L 5.000 104 % 75-125
(CH 1979226-001) MSD ug/L 5.000 108 % 75-125
MSRPD ug/L 5.000 3.6% ≤20
200.8 11/06/19:217491AC ICV ppb 50.00 103 % 90-110
ICB ppb 0.003 1
CCV ppb 50.00 101 % 90-110
CCB ppb -0.003 1
Thallium 200.8 MS ug/L 5.000 106 % 75-125
(CH 1979226-001) MSD ug/L 5.000 110 % 75-125
MSRPD ug/L 5.000 3.6% ≤20
200.8 11/06/19:217491AC ICV ppb 50.00 98.2 % 90-110
ICB ppb 0.003 0.2
CCV ppb 50.00 97.9 % 90-110
CCB ppb 0.001 0.2
Vanadium 200.8 MS ug/L 5.000 117 % 75-125
(CH 1979226-001) MSD ug/L 5.000 116 % 75-125
MSRPD ug/L 5.000 0.3% ≤20
200.8 11/06/19:217491AC ICV ppb 50.00 99.5 % 90-110
ICB ppb -0.001 2
CCV ppb 50.00 102 % 90-110
CCB ppb -0.01 2
Mercury 245.1 11/05/19:212722ac Blank ug/L ND <0.02
LCS ug/L 0.2000 85.2 % 85-115
MS ug/L 0.2000 80.9 % 75-125
(CH 1979080-001) MSD ug/L 0.2000 83.5 % 75-125
MSRPD ug/L 0.2000 3.2% ≤20
245.1 11/05/19:217300AC CCV ppt 200.0 98.6 % 90-110
CCB ppt 1.2 20
CCV ppt 200.0 93.8 % 90-110
CCB ppt 1.6 20
Definition
ICV : Initial Calibration Verification - Analyzed to verify the instrument calibration is within criteria.
ICB : Initial Calibration Blank - Analyzed to verify the instrument baseline is within criteria.
CCV : Continuing Calibration Verification - Analyzed to verify the instrument calibration is within criteria.
CCB : Continuing Calibration Blank - Analyzed to verify the instrument baseline is within criteria.
Blank : Method Blank - Prepared to verify that the preparation process is not contributing contamination to the samples.
LCS : Laboratory Control Standard/Sample - Prepared to verify that the preparation process is not affecting analyte recovery.
MS : Matrix Spikes - A random sample is spiked with a known amount of analyte. The recoveries are an indication of how that sample
matrix affects analyte recovery.
November 11, 2019 Lab ID : CH 1979226
Micheal Dunn Customer : 7-2229
Quality Control - Inorganic
Definition
MSD : Matrix Spike Duplicate of MS/MSD pair - A random sample duplicate is spiked with a known amount of analyte. The recoveries
are an indication of how that sample matrix affects analyte recovery.
MSRPD : MS/MSD Relative Percent Difference (RPD) - The MS relative percent difference is an indication of precision for the preparation
and analysis.
ND : Non-detect - Result was below the DQO listed for the analyte.
DQO : Data Quality Objective - This is the criteria against which the quality control data is compared.