HomeMy WebLinkAboutFAI CF Fire Pump Report CSA 137 12_2019Durham`, . Pump 2313 Durham -Dayton Hwy. Durham, CA 95938 530.891.4821 CSA#137 Durham CUSTOMER NAME: Butte County Fire Dept. PUMP CHECK REPORT Industrial Partners DATE. 12/12/19 Motor Mfg: US motors HP: 100 Meter #: 1005520819 RPM 1775 Volts 460 Phase 3 Rated Amps: 120 TM 80E—]Yes F—]No Serial# T07TO59ROOSR-12 PG &E Acct. # Other: Panel Mfg: Delta NEMA Size: 3 Type: ❑ X/L P/VV Other: Pump Mfg: Serial#: Non -Running Checks: Pump Model Manufacturer ❑ Lubricant Levels - Service and Change if Necessary Oiler Unit and/or Packing ❑ Electrical Leads & Connections - Repair and Tighten as Necessary Incoming Idle Voltage: F]W/I Acceptable Limits Unacceptable ❑ Fuses - Replace if Necessary FIReplaced Size: 150A MCP ❑ Perform General Clean -Up of Electrical Panel and Motor Running Checks: Motor winding resistance: Excessive or Unusual Noise 1-10k Excessive or Unusual Vibration F]Ok Control Devices: 1-1 H.O.A. Start Switch Time Clock Frost Start Time Delay Other: Pressure Switch Amperage: Expected: 120.5 Actual: L1: 115 L2: 112.8 L3: 126.7 Average: 118.2 Overload Underload Even Load Bowl Adjustment: Yes ❑X No Comments: Slightly uneven load, similar to previous inspection. GPS: 39038'41.08"N 121°43'18.99"W The above readings reflect the site and pump conditions at the time of inspection. This report does not guarantee the continuation of these conditions, nor warranty any part of the existing system. S:\Pump Dept. Files\PUMP TESTS & INSPECTIONS\Cal Fire CSA's\137 Durham Dayton Ind Partn\137 Reports Durhami : Pump 2313 Durham -Dayton Hwy. Durham, CA 95938 530.891.4821 PUMP CHECK REPORT CSA #137 Durham Dayton Industrial Partners CUSTOMER NAME: Butte County fire Dept DATE: 12/12/19 Motor Mfg: Franklin HP: 3 Meter #: RPM 3450 Volts 460 Phase 3 Rated Amps: 4.8 TM 80E—] Yes F—]No Serial # PG &E Acct. # Other: Panel Mfg: IEC NEMA Size: ? Type: ❑ X/L F] P/W Other: Pump Mfg: SUB Serial#: Non -Running Checks: Pump Model Manufacturer na FILubricant Levels - Service and Change if Necessary Discharge na Oiler Unit and/or Packing ❑ Electrical Leads & Connections - Repair and Tighten as Necessary Incoming Idle Voltage: F]W/I Acceptable Limits Unacceptable ❑ Fuses - Replace if Necessary FIReplaced Size: TSR10R ❑ Perform General Clean -Up of Electrical Panel and Motor Running Checks: Motor winding resistance: Q's to ground Excessive or Unusual Noise F]Ok/see comments Pressure tank: OK Excessive or Unusual Vibration 1-1Ok/see comments Tank condition: good Control Devices: ❑ H.O.A. Start Switch Time Clock Frost Start Time Delay Other: Amperage: Expected: 4.8 Pressure setting: Actual: L1: 6 L2: 4.8 L3: 4.5 Average: 5.1 Overload Underload Even Load Bowl Adjustment: N/A FYes FINo Comments: GPS: The above readings reflect the site and pump conditions at the time of inspection. This report does not guarantee the continuation of these conditions, nor warranty any part of the existing system. SAPump Dept. Files\PUMP TESTS & INSPECTIONS\Cal Fire CSA's\137 Durham Dayton Ind Partn\137 Reports