HomeMy WebLinkAboutFAI CF Fire Pump Report CSA 137 12_2019 (2) Durham ': Pump PUMP CHECK REPORT
2313 Durham-Dayton Hwy.
Durham, CA 95938 530.891.4821 CSA#137 Durham Dayton Industrial Partners
CUSTOMER NAME: Butte County Fire Dept. DATE: 12/12/19
Motor Mfg: US motors HP: 100 Meter#: 1005520819
RPM 1775 Volts 460 Phase 3 Rated Amps: 120
TM 80 Yes No Serial# TO7T059ROOSR-12
PG &E Acct. # Other:
Panel Mfg: Delta NEMA Size: 3
Type: X/L n P/W Other:
Pump Mfg: Serial#:
Non-Running Checks: Pump Model Manufacturer
Lubricant Levels -Service and Change if Necessary
Oiler Unit and/or Packing
Electrical Leads & Connections- Repair and Tighten as Necessary
Incoming Idle Voltage: W/I Acceptable Limits Unacceptable
Fuses- Replace if Necessary Replaced Size: 150A MCP
Perform General Clean-Up of Electrical Panel and Motor
Running Checks: Motor winding resistance:
Excessive or Unusual Noise Ok
Excessive or Unusual Vibration Ok
Control Devices: H.O.A. Start Switch Time Clock
Frost Start Time Delay Other: Pressure Switch
Amperage: Expected: 120.5
Actual: Li: 115 L2: 112.8 L3: 126.7 Average: 118.2
Overload Underload Even Load
Bowl Adiustment: [7Yes nNo
Comments:
Slightly uneven load, similar to previous inspection.
GPS: 39°38'41.08"N 121°43'18.99"W
The above readings reflect the site and pump conditions at the time of inspection.
This report does not guarantee the continuation of these conditions, nor warranty any part of the existing system.
S:\Pump Dept. Files\PUMP TESTS&INSPECTIONS\Cal Fire CSA's\137 Durham Dayton Ind Partn\137 Reports
Durham Pump PUMP CHECK REPORT
2313 Durham-Dayton Hwy.
Durham, CA 95938 530.891.4821 CSA#137 Durham Dayton Industrial Partners
CUSTOMER NAME: Butte County fire Dept DATE: 12/12/19
Motor Mfg: Franklin HP: 3 Meter#:
RPM 3450 Volts 460 Phase 3 Rated Amps: 4.8
TM 80 Yes No Serial#
PG &E Acct. # Other:
Panel Mfg: IEC NEMA Size: ?
Type: X/L P/W Other:
Pump Mfg: SUB Serial#:
Non-Running Checks: Pump Model Manufacturer
na Lubricant Levels- Service and Change if Necessary Discharge
na Oiler Unit and/or Packing
Electrical Leads & Connections - Repair and Tighten as Necessary
Incoming Idle Voltage: W/I Acceptable Limits Unacceptable
Fuses - Replace if Necessary Replaced Size: TSR1OR
Perform General Clean-Up of Electrical Panel and Motor
Running Checks: Motor winding resistance: O's to ground
Excessive or Unusual Noise Ok/see comments Pressure tank: OK
Excessive or Unusual Vibration Ok/see comments Tank condition: good
Control Devices: H.O.A. Start Switch Time Clock
Frost Start Time Delay Other:
Amperage: Expected: 4.8 Pressure setting:
Actual: L1: 6 L2: 4.8 L3: 4.5 Average: 5.1
Overload Underload Even Load
Bowl Adjustment: N/A Yes No
Comments:
GPS:
The above readings reflect the site and pump conditions at the time of inspection.
This report does not guarantee the continuation of these conditions, nor warranty any part of the existing system.
S:\Pump Dept. Files\PUMP TESTS&INSPECTIONS\Cal Fire CSA's\137 Durham Dayton Ind Partn\137 Reports