Loading...
HomeMy WebLinkAboutFAI15-0009 CF Fire Alarm 2017 DATE: 4-`i-E-1 ,� IS OEAGLSecurity Systems FI�R/E INSPECTION &TESTING PH:(530) 345-6395 NNUAL TIME:❑QUARTERLY E AX:(530) 345-2459 TIME: ANNUAL Li MONTHLY 3268 Esplanade, Chico, CA. 95973 ❑SENSITIVITY C10#388398 LIC#ACO-4462 AGENCIES CONTACTED NAME:Paradise Pines Homeowners Association CONTACT TMS ADDRES5:14211 WyGNtI Way PHONE:1-888-610-4377 CITY:Magalia MONITORING ACCT.tt;221-1851 CONTACT:Robin Ferry FIRE DEPARTMEAET:Butte County PHONE:873-1114 PHONE:533-6363 INSPECTORS:-14-es"*k I c2.1 C‘N.Coov"As, PHONE LINES VERIFY TEST •J PRIMARY:873-3438 t( PANEL MANUFACTURER :Bosch SECONDARY:873-1115 Cf 2 ' MODEL NUMBER:6v4 SLAVE DIALER: TRANSMISSION TYPE SYSTEM POWER SUPPLIES ❑INTERNET ❑CELLULAR PRIMARY(MAIN):AC VOLTAGE: Unknown 0 PHONE LINE ❑RADIO LOCATION(AC SUBPANEL):Unknown Li LOCAL ONLY ❑Other; CIRCUIT BREAKER#: X Former below FACP FIRE ALARM INDICATING APPUANCES AND CIRCUIT INFORMATION # BATTERY TYPE VOLTS AH YEAR CONDITION/COMMENTS 1 SLA Duracell 8F \'3 .V4 10.GS-2016 FACP 2 SLA Duracell 8F 19.ci(# tt.'►j 2016 FACP 3 SLA Duracell 8F ILL('I j0,('"2015 Power Supply In Attic # TYPE SUP VOLTS TYPE VISUAL PASS FAIL STROBE ONLY YESDNO❑ CONTROL PANEL IIv" Ie' [U HORN ONLY YESG1 NOD LAMPS/LEDS UII Efts ❑ HORN/STROBE YESfd NOD FUSES ❑00,/ ❑ CHIME/STROBE YES❑NOM REMOTEANNUN Yd airEl — CHIMES YES[]NOD REMOTEANNUN ❑ El ❑ 2 BELLS YESO NO[l 12 REMOTE ANNUN ❑ ❑ ❑ BELL YES❑NOI I DISCONNECT SWITCHES ❑ ❑ ❑ SPEAKERS YES❑NOD DOOR HOLDER YES❑NO❑ BOOSTERS VOICE-EVAC MANUFACTURER CIRCUIT DOOR HOLDER NAC VOLTS SUPERVISED YES❑ NOD YES❑ NOD YES❑ NO❑ Comments; Page 1 of 3 Account#: 221-1851 Account Name:Paradise Pines Homeowners Date: 4-let-t1 Page 2 of 3 Device Cleaning Factory Meas. Zone Zone Location&Identification Type Timerums Setting Setting Pass Fail 2 Bell Supervisory Sup it"�❑ � 0 3 Library North East Photo _✓ to ❑0 4 Admin Hall South Photo 5 Batt Super Mod Sup / ❑ e/ 0 / 4 Admin Hall North Photo , / Cif; 0 11 Crawl Library Heat ✓ 0 LS7 Ui 13 Hobby Room Heat ❑ PC 3 Library South East Photo -?v Pr� 0 15 Board Room Heat / 0 uf0 16 S.Office Admin Assist Heat , 0 fl 0 10 Library SW Heat */ 0 le 0 18 Lounge North East Corner Heat V 0 (ie.' 0 10 Library S Mid Heat lc ❑ [' ❑ 10 Library NE Heat 0 e* 0 21Cafeteria Attic Heat 0 222 Cafeteria Hall Heat ❑ W' 0 10 Library N Mid Heat ✓ 0 IP 0 24 Cafeteria Crawl Space Heat 1, "IJ �V,/ 0 36 Water Flow/Dry Pipe WF V 0 iV 0 3 Library West Photo ✓ B re. U 12 Attic NE Heat �- J ��1 0 L 12 Attic NW Heat 0 �/r ❑ 12 Attic NW Mid Heat /- ❑ MI, 0 12 Attic NE Mid Heat Vi. ❑ t� ❑ 12 Attic SE Mid Heat V 0 t' 12 Attic SW Heat ✓ 0 d 0 12 Attic SE Heat ✓ 0 It 0 17 Office Crawl Heat u/ 0 le 0 111_ Womens Restroom Heat ✓ 0 re�/ 0 14 Accountant Office Heat ,✓ 0 t t ❑ 16 Mens Restroom Heat y=! C�/ 0 14 Architectural Control Heat 0 i±a 0 16 Nugget Heat ,✓ 0 l' 0 15 Manager Heat v/ ❑ 91'' 0 16 Copy Room Heat 1V 0 t 0 14 Activity Leader Heat 1/ 0 ._�! 0 18 Lounge Entry Heat ice 0 i#rr/ ❑ 19 Bar Heat toe 0 „Ld1 0 1� Restroom South Hall Heat V 0 I..,/ 0 19 Restroom Womens South Heat 0 ❑ 19 Restroom Mens South Heat 0 le" ❑ 18 Lounge North Fast Heat El le 0 _tS Lounge South West Heat fr 0 +V 0 18 Lounge South East Heat 0 1 ❑ 18 Lounge North West Heat 0 ❑ 18 Lounge East Corner Heat �❑ 0 20 Cafeteria Heat [ ❑ 22 HVAC/Water Heater Closet Heat ❑ ❑ 19 South Liquor Closet Heat 0 ❑ 22 North Liquor Closet Heat ❑ 1 0 �j 22 N Restroom Hall N Heat Y ❑ 1 _2_2__ __ N Restroom Hall S _HUI_ 0 d 22 Womens Locker Room Heat 0 es,f / 0 22 Mens Locker Room Heat 0 Fr 0 23 Dance Hall N Mid Heat ❑ IV 0 23 Dance Hall N Heat [1 Ve 0 20 Stage Heat Q the ❑ 23 Dance Hall N Center Heat /,--0 liie 0 23 Dance Hall Center Heat 0 le 0 23 Dance Hall S Center Heat 0 le 0 23 Dance Hall S Mid Heat 0 if 0 23 Dance Hall S Heat f 00 17 Office Crawl Heat --v� 0 0 17 Office Crawl Heat +� +0 Eifr 0 18 Maintenance Office Heat 0 lW 0 Account#: 221-1851 Account Name:Paradise Pines Homeowners", Date: 41-q-11 Page 3 of!. Device Cleaning Factory Meas. Zone Zone Location&Identification Type Tirt,)eetrums Setting Setting Pass Fail 11 Crawl Library Heat 0 Z. 0 11 Crawl Library Heat 7 0 Pte 17 Office Crawl Heat 0 Er 0 q Tekpovt.. 1-610.6 e 0 O 0 0 O on O on O GD O on 0 0 0 0 0 0 00Lii ono o 0 0 O on o no O 00 00o O 0 0 Li 0 0 DoLi [1 0 0 Ll 0 0 LI 0 0 O 0 [1 O El 0 O 0 0 O LI 0 O 0 Li O LI 0 L o 0 Li O 0 Li O 0 LI Li 0 Li LI 0 El El El 0 O 0 0 Li 0 0 O LI L7 O L7 0 O 0 Ii I 1 CI O Li CI Li 0 0 o 1.1 Li o LI 0 THIS TESTING WAS DONE IN ACCORDANCE WITH NFPA STANDARDS TYPE SINAL RESTORAL NOTIFICATION OF COMPLETION ALARM DIVES LiMO gES ENO BUILDING MANAGEMENT *ES LINO TROUBLE AES LINO S LINO MONITORING AGENCY I:YES ONO SUPERVISORY AS ENO !WIVES ENO FIRE DEPARTMENT LiKES ONO INSPECTOR: "retyvA D ATE: I T : vac" RPASSED siGNATURE REPRESENTATIVE DATE: TIME: -1 FAILED SIGNATURE: