Loading...
HomeMy WebLinkAboutFAI19-0024 CF Fire Alarm Test 2020 - Gozi o i p 25c -0 9 Fire Alarm and Life Safety System Inspection Certificate For WASHINGTON COURT APARTMENTS 1001 WASHINGTON STREET GRIDLEY, CA 95948 Tested to NFPA 72 Standards This Inspection was performed in accordance with applicable NFPA Standards. The subsequent pages of this report provide performance measurements, listed ranges of acceptable results, and complete documentation of the inspection. Whenever discrepancies exist between acceptable performance standards and actual test results, notes and/or recommended solutions have been proposed or provided for immediate review and approval. Annual Inspection Inspection Date Jan 10, 2020 Building:WASHINGTON COURT APARTMENTS Company:Hue&Cry,Inc. Contact: Scott Busch Contact:CESAR HERNANDEZ Title: REGIONAL MANAGER Title:INSPECTOR Executive Summary Generated by:BuildingReports.corn Building:WASHINGTON COURT APARTMENTS Contact: Scott Busch Address: 1001 WASHINGTON STREET Phone: 1530846-2600 Address: Fax: City/State/Zip: GRIDLEY, CA 95948 Mobile: Country: United States of America Email: SBUSCH@CRESAPTS COM In ection Performed By Company: Hue&Cry, Inc. Inspector: CESAR HERNANDEZ Address: 1751 Bruce Drive Phone: 9166064121 Address: Fax: City/State/Zip:Anderson, California 96007 Mobile: 19166064121 Country: United States Email: C HERNANDEZ@HUEANDCRY COM Sys Una Manufacturer: Silent Knight Inspection Date: 01/10/2020 IDC Style: Model Number: SK-5700 Install Date: 10/25/2011 SLC Style: Software Version: 10.05 Version Date: 06/10/2010 NAC Style:Y Location: Bldg H Office Current Protection: Breaker Company: Phone: Account#: ,. �.�y" "K`?L !" ti � ,. �i i .^ a�yY9r ,qt c5 us+ alS�io Sin veri acaiion Type: Mfg: Model#: Test Time/Date: Restore Time: Hue&Cry,Inc. Page 1 of 13 01/17/2020 Executive Summary Total Items Serviced Passed Failed/Other Category:g ry: Qty % Qty ` % I Qty 1 % Qty 1 % Control 15 23.44% 15 100.00% 15 100.00% 0 0% Monitor 10 15.62% 10 100.00% 10 100.00% 0 0% Initiating 9 14.06% 9 100.00% 9 100.00% 0 0% Supervisory 11 17.19% 11 100.00% 11 100.00% 0 0% Indicating 19 29.69% 19 100.00% 1 19 100.00% 0 0% Totals 64 1 100% ; 64 1100 00% , 64 1 104 00°!° 0 0% Company: Hue&Cry, Inc. Building:WASHINGTON COURT APARTMENTS Inspector:CESAR HERNANDEZ Contact: Scott Busch C/ . : —'-- Signed:Jan 10,2020 Signed:Jan 10,2020 Hue&Cry,Inc. Page 2 of 13 01/17/2020 Executive Summary Notes & Recommendations Generated by:BuildingReports.com The Notes&Recommendations Report details additional inspection notes made by the Inspectors during the course of the building inspection. Notes are grouped by Category. Replaced 2 12v 12a in the Fire Control Panel Replaced 4 12v 7a in Buildings F and B Hue&Cry,Inc. Page 3 of 13 01/17/2020 Notes&Recommendations Inspection & Testing Generated by:BuildingReports.com The Inspection& Testing section lists all of the items inspected in your building. Items are grouped by Passed or Failed/Other. Items are listed by Category. Each item includes the services performed, and the time&date at which testing occurred. � t `ib, re abi. a., Ri d..an.. z.i_ Control Annunciator Inside Office Tested 1:34:55 PM 01/10/2020 Battery Bldg B Replaced 1:22:41 PM 01/10/2020 Battery Bldg B Replaced 1:23:11 PM 01/10/2020 Battery Bldg F Replaced 1:31:27 PM 01/10/2020 Battery Bldg F Replaced 1:32:05 PM 01/10/2020 Battery Bldg H FACP Replaced 1:09:22 PM 01/10/2020 Battery Bldg H FACP Replaced 1:09:51 PM 01/10/2020 Control Panel Bldg H Office Tested 1:00:08 PM 01/10/2020 Disconnect Bldg B Circuit 3 Outside Tested 1:25:04 PM 01/10/2020 ' Disconnect Bldg F Circuit 3 Outside Tested 12:57:16 PM 01/10/2020 Disconnect Bldg H Office Boiler Room Circuit 2 Tested 1:37:02 PM 01/10/2020 Phone Jack I Bldg H FACP 530-846-2136 Pri Tested 1:16:30 PM 01/10/2020 Phone Jack Bldg H FACP 530-846-2154 Sec Tested 1:16:27 PM 01/10/2020 Power Supply Bldg B Tested 11:57:46 AM 01/10/2020 Power Supply Bldg F Tested 12:46:26 PM 01/10/2020 Indicating Horn/Strobe Bldg D Riser Tested 12:17:44 PM 01/10/2020 Horn/Strobe Bldg A Riser Riser Tested 11:43:06 AM 01/10/2020 Horn/Strobe Bldg B Apt 9 Bed 1 ADA Tested 9:36:42 AM 01/10/2020 ' Horn/Strobe Bldg B Apt 9 Bed 2 ADA Tested 9:36:30 AM 01/10/2020 Horn/Strobe Bldg B Apt 9 Bed 3 ADA Tested 9:36:22 AM 01/10/2020 Horn/Strobe Bldg B Apt 9 Living Room ADA Tested 10:39:01 AM 01/10/2020 Horn/Strobe Bldg B Riser Riser Tested 11:53:23 AM 01/10/2020 Horn/Strobe Bldg C Riser Riser Tested 11:59:53 AM 01/10/2020 Horn/Strobe Bldg E Riser Riser Tested 12:55:29 PM 01/10/2020 Horn/Strobe Bldg F Apt 41 Bed 1 ADA Tested 10:38:01 AM 01/10/2020 Horn/Strobe Bldg F Apt 41 Bed 2 ADA Tested 10:38:51 AM 01/10/2020 Horn/Strobe Bldg F Apt 41 Living Room ADA Tested 10:38:40 AM 01/10/2020 Horn/Strobe Bldg F Riser Tested 12:50:09 PM 01/10/2020 Horn/Strobe Bldg G Riser Tested 12:08:16 PM 01/10/2020 Horn/Strobe Bldg H Office Lobby Tested 1:37:47 PM 01/10/2020 Horn/Strobe Bldg H Office Outside Riser Tested 1:14:06 PM 01/10/2020 Strobe Bldg B Apt 9 Bathroom ADA Tested 9:37:03 AM 01/10/2020 Hue&Cry,Inc. Page 4 of 13 01/17/2020 Inspection&Testing i. ��pp ` /' �,,..Z%4a �" as 4 � ,fin A� �' P: ,,, �r<�, � '�� �., � 4�1 � 4... ,..,gib Strobe Bldg B Apt 9 Master Bath ADA Tested 9:36:10 AM 01/10/2020 Strobe Bldg F Apt 41 Bed 1 ADA Tested 10:38:19 AM 01/10/2020 Initiating Smoke Detector Office Riser Tested 1:16:20 PM 01/10/2020 Waterflow Switch Bldg A-ITV in Access Door Tested 11:38:08 AM 01/10/2020 Waterflow Switch Bldg B-ITV in Access Door Tested 9:52:22 AM 01/10/2020 Waterflow Switch Bldg C-ITV in Access Door Tested 12:01:45 PM 01/10/2020 Waterflow Switch Bldg D-ITV in Access Door Tested 12:18:56 PM 01/10/2020 Waterflow Switch Bldg E-ITV in Access Door Tested 12:55:01 PM 01/10/2020 Waterflow Switch Bldg F-ITV in Access Door Tested 12:48:56 PM 01/10/2020 Waterflow Switch Bldg G-ITV in Access Door Tested 12:11:04 PM 01/10/2020 Waterflow Switch Bldg H Office-ITV in Access Door Tested 1:10:15 PM 01/10/2020 Monitor Monitor Device Bldg A Riser Room Tested 11:42:46 AM 01/10/2020 Monitor Device Bldg A Riser Room Tested 11:42:53 AM 01/10/2020 Monitor Device Bldg B Riser Room Tested 11:57:42 AM 01/10/2020 Monitor Device Bldg C Riser Room Tested 12:00:31 PM 01/10/2020 Monitor Device Bldg C Riser Room Tested 12:00:38 PM 01/10/2020 Monitor Device Bldg D Riser Room Tested 12:17:21 PM 01/10/2020 Monitor Device Bldg D Riser Room Tested 12:17:31 PM 01/10/2020 Monitor Device Bldg E Riser Room Tested 12:55:18 PM 01/10/2020 Monitor Device Bldg F Riser Room Tested 12:47:53 PM 01/10/2020 Monitor Device Bldg G Riser Room Tested 12:10:49 PM 01/10/2020 Supervisory Tamper Switch Backflow by Bldg A Tested 11:47:23 AM 01/10/2020 Tamper Switch Backflow by Bldg A Tested 11:47:34 AM 01/10/2020 Tamper Switch Backflow by Bldg D Tested 12:37:14 PM 01/10/2020 Tamper Switch Backflow by Bldg D Tested 12:40:46 PM 01/10/2020 Tamper Switch Bldg A Tested 11:37:53 AM 01/10/2020 Tamper Switch Bldg B Tested 11:52:42 AM 01/10/2020 Tamper Switch Bldg C Tested 12:01:12 PM 01/10/2020 Tamper Switch Bldg D Tested 12:17:12 PM 01/10/2020 Tamper Switch Bldg F Tested 12:47:44 PM 01/10/2020 Tamper Switch Bldg G Tested 12:51:34 PM 01/10/2020 Tamper Switch Bldg H Office Tested 12:59:59 PM 01/10/2020 Hue&Cry,Inc. Page 5 of 13 01/17/2020 Inspection&Testing Service Summary Generated by:BuildingReports.com The Service Summary section provides an overview of the services performed in this report. r Annunciator Tested 1 Battery Replaced 6 Control Panel Tested 1 Disconnect Tested 3 Horn/Strobe Tested 16 Monitor Device Tested 10 Phone Jack Tested 2 Power Supply Tested 2 Smoke Detector Tested 1 Strobe Tested 3 Tamper Switch Tested 11 Waterflow Switch Tested 8 Total 64 Hue&Cry,Inc. Page 6 of 13 01/17/2020 Service Summary Auxiliary Functions Testing Generated by:BuildingReports.com The Auxiliary Functions Testing section lists each of the ancillary items,systems, and emergency equipment that are controlled by the system control unit. Items are grouped by Passed or Failed/Other. The items are listed by device type, and a check box is provided to indicate if the test conducted was simulated. Smoke Detector Smoke Compartment Office Riser Passed 32022040 Hue&Cry,Inc. Page 7 of 13 01/17/2020 Auxiliary Functions Testing Time, Temperature & Level Testing Generated by:BuildingReports.com The Time, Temperature, &Level Testing section details the measurements taken from various devices that are designed to respond in a certain amount of time, respond at a certain temperature, or respond within the acceptable range of volume or level. Items are grouped by Passed or Failed/Other. Waterflow Switch Bldg A-ITV in Access Door Passed 50 n/a n/a 32022038 Bldg B-ITV in Access Door Passed 45 n/a n/a 32022028 Bldg C-ITV in Access Door Passed 52 n/a n/a 32022023 Bldg D-IN in Access Door Passed 37 n/a n/a 32022019 Bldg E-IN in Access Door Passed 31 n/a n/a 32022011 Bldg F-IN in Access Door Passed 48 n/a n/a 32022004 Bldg G-IN in Access Door Passed 45 n/a n/a 32021999 Bldg H Office-IN in Access Door Passed 10 n/a n/a 32022043 Hue&Cry,Inc. Page 8 of 13 01/17/2020 Time,Temperature&Level Testing Battery & Power Supply Testing Generated by:BuildingReports.corn The Control&Power Testing section details the readings and measurements of batteries and power supplies used to provide power to the fire alarm and life safety systems. Items are grouped by Passed or Failed/Other. , S P Battery Sealed Lead Acid Bldg B 7 12 Sealed Lead Acid Bldg B 7 12 Sealed Lead Acid Bldg F 7 12 Sealed Lead Acid Bldg F 7 12 Sealed Lead Acid Bldg H FACP 12 12 Sealed Lead Acid Bldg H FACP 12 12 Power Supply Bldg B 6 24 Bldg F 6 24 Hue&Cry,Inc. Page 9 of 13 01/17/2020 Battery&Power Supply Testing Inventory & Warranty Report Generated by:BuildingReports.com The Inventory& Warranty Report lists each of the devices and items that are included in your Inspection Report. A complete inventory count by device type and category is provided. Items installed within the last 90 days, within the last year, and devices installed for two years or more are grouped together for easy reference. Strobe Indicating 4.69% 3 Horn/Strobe Indicating 25.00% 16 Waterflow Switch Initiating 12.50% 8 Tamper Switch Supervisory 17.19% 11 Monitor Device Monitor 15.62% 10 Power Supply Control 3.12% 2 Disconnect Control 4.69% 3 Control Panel Control 1.56% 1 Battery Control 9.38% 6 Smoke Detector Initiating 1.56% 1 Phone Jack Control 3.12% 2 may,( Annunciator Control 1.56% 1 Power-Sonic Battery 2 PS-12120 F1 Sealed Lead Acid 01/10/2020 Battery 4 PS-1270 Fl Sealed Lead Acid 01/ 00/2020 Silent Knight Smoke Detector 1 SK PHOTO Photoelectric 10/07/2016 �,,, ✓ � ... �.. _ �_ ,„.... _. ram � Silent Knight Monitor Device 1 SK-MONITOR-2 dual 11/11/2014 System Sensor Horn/Strobe 2 P2RK 11/11/2014 KISCO Tamper Switch 2 KT-505W-8 10/28/2011 Silent Knight Monitor Device 1 SK-MONITOR-2 10/28/2011 Monitor Device 2 SK-MONITOR-2 Dual 10/28/2011 Power Supply 1 5496 10/28/2011 System Sensor Waterflow Switch 4 WFD25 10/28/2011 Hue&Cry,Inc. Page 10 of 13 01/17/2020 Inventory&Warranty Report Disconnect 3 Breaker 10/25/2011 Napco Tamper Switch 1 OSY2 10/25/2011 NIBCO Tamper Switch 1 GD-4765-8N 10/25/2011 Tamper Switch 4 KY-505W-8 10/25/2011 Silent Knight Annunciator 1 LCD Display 10/25/2011 Control Panel 1 SK-5700 10/25/2011 Monitor Device 3 SK-MONITOR 10/25/2011 Monitor Device 3 SK-MONITOR-2 dual 10/25/2011 Phone Jack 2 SK-5700 10/25/2011 Power Supply 1 5496 10/25/2011 System Sensor Horn/Strobe 2 P2R 10/25/2011 Horn/Strobe 5 P2RK 10/25/2011 Tamper Switch 3 OSY2 10/25/2011 Waterflow Switch 4 WFD25 10/25/2011 System Sensor Horn/Strobe 7 P2RK 10/11/2009 Strobe 2 10/11/2009 Strobe 1 P2RK 10/11/2009 Hue&Cry,Inc. Page 11 of 13 01/17/2020 Inventory&Warranty Report Zone Address Report Generated by:BuildingReports.corn • The Zone Address Report lists all of the devices and items that have an individual address, or are grouped together under a common zone. The device type, location, and description are included for your reference. Zone/Circuit: 004,005` Monitor Device Bldg A Riser Room dual 32022035 Zone/Circuit: 005 Tamper Switch Bldg A 32022037 Tamper Switch Bldg H Office 32022042 Zone/Circuit: 006,007 Monitor Device Bldg B Riser Room dual 32022029 Zone/Circuit: 007 Tamper Switch Bldg B 32022027 Zone/Circuit: 008 Tamper Switch Bldg C 32022024 Monitor Device Bldg C Riser Room 32022022 Zone/Circuit: 009 Waterflow Switch Bldg C-ITV in Access Door 32022023 Monitor Device Bldg C Riser Room 32022021 Zone/Circuit: 013 Waterflow Switch Bldg D-ITV in Access Door 32022019 Zone/Circuit: 013,014 Monitor Device Bldg D Riser Room dual 32022017 Zone/Circuit: 014 Tamper Switch Bldg D 32022018 Zone/Circuit:015 Tamper Switch Bldg G 32022012 Zone/Circuit: 015,016 Monitor Device Bldg E Riser Room Dual 32022010 Zone/Circuit: 016 Waterflow Switch Bldg E-ITV in Access Door 32022011 Zone/Circuit: 018 Tamper Switch Bldg F 32022003 Zone/Circuit: 018, 019 Monitor Device Bldg F Riser Room Dual 32022005 Monitor Device Bldg G Riser Room 32022001 Zone/Circuit: 019 Waterflow Switch Bldg F-ITV in Access Door 32022004 Hue&Cry,Inc. Page 12 of 13 01/17/2020 Zone Address Report Y ✓' Vi- , a, - f Rr1j '+' e,` b,r p "ry:�. ^.: + <,' : a,- t .b �y ,4 ,:grs4a , ^ 3Jk�,,, ,a Waterflow Switch Bldg G-ITV in Access Door 32021999 Waterflow Switch Bldg H Office-ITV in Access Door 32022043 Zone/Circuit: 049 . Monitor Device Bldg D Riser Room 32022016 01 Tamper Switch Backflow by Bldg D 32022014 02 Tamper Switch Backflow by Bldg D 32022015 Zone/Circuit: 050 Monitor Device Bldg A Riser Room dual 32022036 01 Tamper Switch Backflow by Bldg A 32022034 02 Tamper Switch Backflow by Bldg A 32022033 Zone/Circuit: 4 Waterflow Switch Bldg A-ITV in Access Door 32022038 Zone/Circuit:A Power Supply Bldg B 32022032 Zone/Circuiit: B Power Supply Bldg F 32022008 Zone/Circuit: M02 i Bottom Battery Bldg B Sealed Lead Acid 61628414 Right Bottom Battery Bldg B Sealed Lead Acid 61628415 Right Zone/Circuit: M03 Bottom Left Battery Bldg F Sealed Lead Acid 61628412 Bottom Left Battery Bldg F Sealed Lead Acid 61628413 Hue&Cry.Inc. Page 13 of 13 01/17/2020 Zone Address Report