HomeMy WebLinkAboutADM20-0092 Application_ApprovedTEW RC x x 20-0092 xx July 9, 2020 RADIATOR/EXHAUST/FUEL END DISCHARGE BATTERY B O X POWER CENTER &CONTROLSBOLT ON P A NE L S 5' VENT R A D I U S 5' VENT RADIUS 5' VENT R A D IU S X X X X XXXXXXXXXXXXXX XXX XXXXX XXXX X XXOVERALL SITE PLAN PO BOX 2621, BOISE, ID 83701 530.539.4787 CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 04/24/20 ISSUED FOR CONSTRUCTION JAD SHEET TITLE: SHEET NUMBER: A-1 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 200 FEET NORTH OF ORO QUINCY HIGHWAY OROVILLE, CA 95966 GENERATOR INSTALLATION PROJECT OLIVE HIGHWAY 10132952 CHECKED BY:GGD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology 09/30/2021 1 05/22/20 ADDED PG&E GROUNDING SPECS JAD OVERALL SITE PLAN N 1SCALE: 1" = 40'-0" (11x17) PROJECT SITE, SEE SHEET A-2 FOR ENLARGED SITE PLAN 200 FEET NORTH OF ORO QUINCY HIGHWAY OROVILLE, CA 95966 TAX ID#: 068-150-051 & 068-150-070 NOTE: EVERYTHING SHOWN IS EXISTING UNLESS MARKED PROPOSED EXISTING CONDITIONS: THESE DRAWINGS WERE PRODUCED WITH INFORMATION PROVIDED BY THE CLIENT. LINES, EASEMENTS, AND SETBACKS SHALL BE VERIFIED PRIOR TO START OF CONSTRUCTION, GEOSTRUCTURAL DOES NOT GUARANTEE THE ACCURACY OF SAID PROPERTY LINE, EASEMENTS AND SETBACKS. OVERHEAD CONDUCTORS DIRT ACCESS DRIVEPROPERTY LINEPROPERTY LINEPARCEL BOUNDARYPARCEL BOUNDARYPROPERT Y L I N E ORO QUINC Y H I G H W A Y TRANSMISSION TOWER ~40' (PARCEL LINE TO GENERATOR) RADIATOR/EXHAUST/FUEL ENDDISCHARGEBATTERY BOXPOWER CENTER &CONTROLSBOLT ON PANELS5' VENT RADIUS5' VENT RADIUS5' VENT RADIUSX X X X XXXXXXXXXXXXXXXXXXXXXXXXXXXXXPOWER ROUTING KEYED NOTES: EXISTING AT&T METER AND DISCONNECT INTERCEPT EXISTING CONDUIT AND CONDUCTORS AND RE-ROUTE THROUGH PROPOSED ATS (~10'). COORDINATE PATH WITH CONSTRUCTION MANAGER EXISTING AC LOAD CENTER PROPOSED AT&T UNDERGROUND GENERATOR CONDUIT ROUTE (~10'). CONTRACTOR TO LOCATE EXISTING UTILITIES PRIOR TO EXCAVATION. SEE SHEETS E-1, E-2. SEE SHEET E-1 FOR SINGLE LINE DIAGRAM. M/D INT AC CON NOTE: EVERYTHING SHOWN IS EXISTING UNLESS MARKED PROPOSED ENLARGED SITE PLAN PO BOX 2621, BOISE, ID 83701 530.539.4787 CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 04/24/20 ISSUED FOR CONSTRUCTION JAD SHEET TITLE: SHEET NUMBER: A-2 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 200 FEET NORTH OF ORO QUINCY HIGHWAY OROVILLE, CA 95966 GENERATOR INSTALLATION PROJECT OLIVE HIGHWAY 10132952 CHECKED BY:GGD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology 09/30/2021 1 05/22/20 ADDED PG&E GROUNDING SPECS JAD 1ENLARGED SITE PLAN N SCALE: 1/4" = 1'-0" (11x17) UTILITY NOTE: THE UTILITIES AS SHOWN ON THIS SET OF DRAWINGS WERE DEVELOPED FROM RECORD INFORMATION. THE INFORMATION PROVIDED IS IMPLIED NOT INTENDED TO BE A COMPLETE INVENTORY OF THE UTILITIES IN THIS AREA. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATION OF ALL UTILITIES (WHETHER SHOWN OR NOT) AND PROTECT SAID UTILITIES FROM ANY DAMAGE CAUSED BY CONTRACTOR'S ACTIVITIES. EXISTING CONDITIONS: THESE DRAWINGS WERE PRODUCED WITH INFORMATION PROVIDED BY THE CLIENT. LINES, EASEMENTS, AND SETBACKS SHALL BE VERIFIED PRIOR TO START OF CONSTRUCTION, GEOSTRUCTURAL DOES NOT GUARANTEE THE ACCURACY OF SAID PROPERTY LINE, EASEMENTS AND SETBACKS. SCOPE OF WORK DETAILS: GENERAL: · NEW GENERAC DIESEL GENERATOR PROVIDED BY GENERAL DYNAMICS & INSTALLED BY GENERAL CONTRACTOR. SEE SHEETS E-4.0, E-4.1, E-4.2. · NEW CONCRETE COMPOUND EXPANSION SLAB PROVIDED & INSTALLED BY GENERAL CONTRACTOR. SEE SHEET S-1. · NEW GENERAC AUTOMATIC TRANSFER SWITCH PROVIDED BY GENERAL DYNAMICS & INSTALLED BY CONTRACTOR. SEE SHEETS S-2, E-5.0, E-5.1. · NEW COMPOUND FENCE EXPANSION PROVIDED & INSTALLED BY GENERAL CONTRACTOR. SEE SHEET S-3. · CONTRACTOR TO VERIFY ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION. · CONTRACTOR SHALL RESTORE & REPAIR ANY DAMAGED AREAS CAUSED BY CONSTRUCTION TO ORIGINAL OR BETTER CONDITION. · INNER AND OUTER TANK TESTING DOCUMENTATION SHALL BE PROVIDED ONCE TANK IS IN PLACE ON SITE IN ACCORDANCE WITH NFPA 30. · A CALIBRATION CHART OF PERMANENT AND DURABLE CONSTRUCTION SHALL BE LOCATED AT THE FILL BOX. CONDUITS: · INSTALL PULL STRING IN EACH CONDUIT. · (1) NEW 2" AND (1) NEW 1" ELECTRICAL CONDUIT WITH CONDUCTORS TO BE INSTALLED FROM NEW GENERATOR TO NEW ATS. CONDUIT PROVIDED AND INSTALLED BY GENERAL CONTRACTOR. SEE SHEETS E-1, E-2. · (2) NEW 1" ELECTRICAL CONDUITS WITH CONDUCTORS TO BE INSTALLED FROM NEW GENERATOR TO AC PANEL. CONDUIT PROVIDED & INSTALLED BY GENERAL CONTRACTOR. SEE SHEETS E-1, E-2. · (1) NEW 1" ALARM CONDUIT & CABLING PROVIDED & INSTALLED BY GENERAL CONTRACTOR. SEE SHEETS E-1, E-2. GROUNDING: · NEW EXOTHERMIC CONNECTION FROM EXISTING GROUND RING TO NEW MECHANICAL CONNECTION AT GENERATOR CHASSIS. GENERAL CONTRACTOR TO VERIFY LOCATION IN FIELD. LOCATE GROUND RODS NO MORE THAN 8'-0" APART. SEE SHEET E-3. H-FRAME: · CONTRACTOR TO PROVIDE NEW H-FRAME FOR ATS INSTALLATION (IF REQUIRED). MATCH EXISTING H-FRAME MATERIAL FOR CONSTRUCTION OF NEW H-FRAME. SEE SHEET S-2. R PROPOSED 8' TALL CHAIN-LINK FENCE WITH CHAIN-LINK SECURITY TOPPER,SEE SHEET S-3.ACCESS CLEARANCE, TYP.36" BREAKERS/ALTERNATOR24" INTAKE/EXHAUSTRBS 3106 BTS RRH UNITS PURCELL SPOOL CAN H-FRAME POWER PLANT CIENA NIU BOX PG&E EMERGENCY SHUT-OFF FIBER TELCO & ALARM CONCRETE TOWER FOUNDATION, TYP. PG&E FOUR LEG TRANSMISSION TOWER WITH AT&T ANTENNAS CONCRETE STOOP GEN PLUG GENERATOR KEYED NOTES: PROPOSED AT&T 30KW DIESEL GENERATOR W/ SOUND ATTENUATED ENCLOSURE, NORMAL/EMERGENCY TANK VENTING AND BASE FUEL TANK ON A CONCRETE PAD. SEE SHEETS S-1, S-2, E-3. FUEL FILL SHALL BE PROVIDED WITH SPILL CONTROL, WITH A SOLID FILL CONNECTION, AND WITH OVERFILL PREVENTION FUEL TANK NORMAL AND EMERGENCY VENTS SHALL TERMINATE AT LEAST 12'-0" ABOVE THE ADJACENT GRADE. SEE SHEET S-2. NFPA 704 PLACARD AND OTHER SIGNAGE. SEE SHEET S-2. GEN 1 2 3 ATS / EQUIPMENT KEYED NOTES: -FIRE EXTINGUISHER, (2A-20BC OR APPROVED EQUAL) PER CFC 906.3 -FIRE EXTINGUISHER CABINET (BFC-7009 OR APPROVED EQUAL), MOUNT TO BUILDING WALL OR H-FRAME PER CFC 906.9 (5'-0" MAX. ABOVE GRADE) EMERGENCY SHUTOFF SWITCH, MOUNT TO BUILDING WALL OR H-FRAME PER CFC 906.9 (5'-0" MAX. ABOVE GRADE) PROPOSED ATS W/ CAMLOCK MOUNTED ON NEW H-FRAME UNISTRUT RAILS WITH 36" FRONT CLEARANCE. SEE SHEET S-2. PROPOSED H-FRAME WITH UNISTRUT RAILS, SEE SHEET S-2. FIRE OFF ATS H-FR M/DINT AC CON GEN 1 2 3 FIRE OFF ATS 3'-5" 3'-0"10'-0" FOUNDATION 3'-0"17'-0"FOUNDATION3'-0"REMOVE AND REPLACE EXISTING WOOD PERIMETER FENCE WITH A PROPOSED 6' TALL CHAIN-LINK FENCE WITH CHAIN-LINK SECURITY TOPPER, SEE SHEET S-3. NEW FENCE POSTS TO BE ANCHORED TO TOP OF EXISTING CONCRETE SLAB. 36" WIDE x 4" THICK CONCRETE APRON ON 2" SAND BASE AROUND PERIMETER OF CHAIN-LINK FENCE AS SHOWN. PROVIDE TOOLED JOINTS AT 4'-0" O.C. AND AT INTERFACES BETWEEN EXISTING CONCRETE/STRUCTURAL ELEMENTS. SLOPE AWAY FROM COMPOUND 1/4" PER FOOT. SUBGRADE TO BE CLEARED, GRUBBED, PROOF-ROLLED AND COMPACTED TO 90% MAXIMUM DENSITY PER D1557. PROVIDE EXPANSION JOINT; DO NOT TIE NEW APRON INTO EXISTING CONCRETE, TYP. 3'-0" 3'-0"3'-7"APPROXIMATE LOCATION OF OVERHEAD CONDUCTORS APPROXIMATE LOCATION OF OVERHEAD CONDUCTORS 9'-11"± H-FR CONCRETE EQUIPMENT SLAB 14'-8" ±4'-7"3'-5" PROVIDE EXPANSION JOINT BETWEEN PROPOSED AND EXISTING CONCRETE CONTRACTOR TO REMOVE ALL SITE SIGNAGE FROM EXISTING FENCE AND REINSTALL ON NEW FENCEPROPOSED CONCRETE COMPOUND EXPANSION. SEE SHEETS S-1 AND S-4. SET TOP OF CONCRETE ELEVATION AT SAME ELEVATION AS EXISTING COMPOUND PAD. 48" CONCRETE APRON EXTENSION IN FRONT OF ACCESS GATE AS SHOWN PROPOSED 4'-0"± WIDE x 6' TALL SWING GATE w/ GATE STOP, SEE SHEET S-3. PG&E GENERATOR DOCUMENT BOX PROPOSED 4'-0"± WIDE x 6' TALL SWING GATE w/ GATE STOP, SEE SHEET S-3. ~1'-8"~2'-9" XX X X XXXX X X X X X X X X X X XXXX X X X X X X X X X X X PO BOX 2621, BOISE, ID 83701 530.539.4787 CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 04/24/20 ISSUED FOR CONSTRUCTION JAD SHEET TITLE: SHEET NUMBER: A-3 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 200 FEET NORTH OF ORO QUINCY HIGHWAY OROVILLE, CA 95966 GENERATOR INSTALLATION PROJECT OLIVE HIGHWAY 10132952 CHECKED BY:GGD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology 09/30/2021 1 05/22/20 ADDED PG&E GROUNDING SPECS JAD ELEVATION VIEWS 1ELEVATION VIEWS NOT TO SCALE EXISTING ELEVATION VIEW PROPOSED ELEVATION VIEW PROPOSED AT&T DIESEL GENERATOR 0'-0"GRADE TANK VENT EXHAUST VENT 146'-5"TOP OF SELF-SUPPORT EXISTING AT&T EQUIPMENT COMPOUND 0'-0"GRADE 7'-8"TOP OF GENERATOR 12'-0"TOP OF EXHAUST PIPESEXISTING WOOD FENCE (TO BE REMOVED) PROPOSED 8' TALL CHAIN-LINK FENCE WITH CHAIN-LINK SECURITY TOPPER PROPOSED 6' TALL CHAIN-LINK FENCE WITH CHAIN-LINK SECURITY TOPPER PG&E FOUR LEG TRANSMISSION TOWER WITH AT&T ANTENNAS (ANTENNAS NOT SHOWN) 3G SEE SITE PLAN1'-0" BLOCKOUT 2'-7"BLOCKOUT2"TANK EXTENTS PERMANUFACTURER#4 U-BARS CONDUIT STUB-UP AREA; CONFIRM LOCATION & SIZE WITH MANUFACTURER (8) 58"Ø x 312" EMBED HILTI KWIK BOLT TZ STAINLESS STEEL EXPANSION ANCHOR (OR APPROVED EQUAL). REFERENCE ICC-ES ESR-1917 REPORT. INSTALLATION TORQUE = 60 FT-LB A SEE SITE PLAN TANK EXTENTS PER MANUFACTURER OUTLINE OF GENERATOR TANK FOOTPRINT SLAB REINFORCEMENT, SEE SHEET S-4 434"312"EMBEDMENT334"HOLE DEPTH1116"Ø HOLE (58"Ø BIT) A CONCRETE NOTES: 1.PRIOR TO EXCAVATION, CHECK THE AREA FOR UNDERGROUND FACILITIES. 2.ALL CONCRETE SHALL BE IN ACCORDANCE WITH CHAPTER 19 OF THE IBC & ACI 318, "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE", LATEST EDITION & HAVE THE FOLLOWING PROPERTIES: A MINIMUM 28-DAY COMPRESSIVE STRENGTH (f'c) OF 2,500 PSI. B CEMENT SHALL BE "LOW-ALKALI" TYPE IIA (MODERATE SULFATE RESISTANCE, AIR ENTRAINING) CONFORMING TO ASTM C150. C MAXIMUM WATER/CEMENT RATIO OF 0.45 AND AIR-ENTRAINED 4% TO 7%. D CONCRETE PROPORTIONING SHALL BE DESIGNED BY AN APPROVED LABORATORY. TOLERANCES IN ACCORDANCE WITH ACI 117. COPIES OF CONCRETE MIX SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW PRIOR TO PLACEMENT. E ALL AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33. USE ONLY AGGREGATES KNOWN NOT TO CAUSE EXCESSIVE SHRINKAGE. MAXIMUM AGGREGATE SIZE TO BE 34". F MAXIMUM SLUMP: REFER TO GEOTECHNICAL REPORT WHEN APPLICABLE. 3.FORMWORK FOR CONCRETE SHALL CONFORM TO ACI 347. TOLERANCES FOR FINISHED CONCRETE SURFACES SHALL MEET CLASS-C REQUIREMENTS. IN NO CASE SHALL FINISHED CONCRETE SURFACES EXCEED THE FOLLOWING VALUES AS MEASURED FROM NEAT PLAN LINES AND FINISHED GRADES: ± 14" VERTICAL, ± 1" HORIZONTAL. 4.CHAMFER ALL EXPOSED CORNERS AND FILLET ENTRANT ANGLES 34" U.N.O. 5.CONCRETE FINISHING: CONCRETE SURFACES SHALL BE FINISHED IN ACCORDANCE WITH ACI. PROVIDE ROUGH FINISH FOR ALL SURFACES NOT EXPOSED TO VIEW AND SMOOTH FINISH FOR ALL OTHERS, U.N.O. 6.STEEL REINFORCEMENT AND CONCRETE SHOULD BE PLACED IMMEDIATELY UPON COMPLETION OF THE FOUNDATION EXCAVATION. CONTRACTOR SHALL NOT ALLOW A COLD JOINT TO FORM IN THE CONCRETE. PORTION AT GRADE SHOULD BE FORMED. TEMPORARY CASING MAY BE REQUIRED TO PREVENT CAVING PRIOR TO CONCRETE PLACEMENT. REINFORCING STEEL NOTES: 1.ALL REINFORCING STEEL SHALL CONFORM TO ASTM A615. VERTICAL/HORIZONTAL BARS SHALL BE GRADE 60; TIES OR STIRRUPS SHALL BE A MINIMUM OF GRADE 40. ALL REINFORCING STEEL SHALL HAVE 3" (± 38") OF CONCRETE COVER, U.N.O. 2.ALL BAR BENDS, HOOKS, SPLICES AND OTHER REINFORCING STEEL SHALL CONFORM TO THE REQUIREMENTS OF ACI 315. 3.ALL BARS SHALL BE SPLICED WITH A MINIMUM LAP OF 48 BAR DIAMETERS. LAP SPLICES OF DEFORMED BARS IN TENSION ZONES SHALL BE CLASS-B SPLICES. WELDING OF BARS IS NOT PERMITTED. 4.AT ALL CORNERS AND WALL INTERSECTIONS, PROVIDE BENT HORIZONTAL BARS TO MATCH THE HORIZONTAL REINFORCING STEEL. 5.PROVIDE VERTICAL DOWELS IN FOOTINGS AND AT CONSTRUCTION JOINTS TO MATCH VERTICAL REINFORCING BAR SIZE AND SPACING. 6.ACI-APPROVED PLASTIC-COATED BAR CHAIRS OR PRECAST CONCRETE BLOCKS SHALL BE PROVIDED FOR SUPPORT OF ALL GRADE-CAST REINFORCING STEEL & SHALL BE SUFFICIENT IN NUMBER TO PREVENT SAGGING. METAL CLIPS OR SUPPORTS SHALL NOT BE PLACED IN CONTACT WITH THE FORMS OR THE SUB-GRADE. 7.DOWELS AND ANCHOR BOLTS SHALL BE WIRED OR OTHERWISE HELD IN CORRECT POSITION PRIOR TO PLACING CONCRETE. IN NO CASE SHALL DOWELS OR ANCHOR BOLTS BE "STABBED" INTO FRESHLY-POURED CONCRETE. FOUNDATION NOTES: 1.THE CONTRACTOR SHALL READ THE GEOTECHNICAL REPORT AND SHALL CONSULT THE GEOTECHNICAL ENGINEER AS NECESSARY PRIOR TO CONSTRUCTION. 2.THE GEOTECHNICAL ENGINEER (OR INSPECTOR) SHALL INSPECT THE EXCAVATION PRIOR TO THE PLACEMENT OF CONCRETE AND SHALL PROVIDE A NOTICE OF INSPECTION FOR THE BUILDING INSPECTOR FOR REVIEW AND RECORDS PURPOSES. 3.THE CONTRACTOR SHALL DETERMINE THE MEANS AND METHODS NECESSARY TO SUPPORT THE EXCAVATION DURING CONSTRUCTION. 4.REBAR AT BOTTOM OF FOUNDATIONS SHALL BE BONDED TO SITE GROUNDING SYSTEM (WHEN APPLICABLE). SEE ADDITIONAL DETAILS ON APPROVED A&E CONSTRUCTION DRAWINGS. 5.ALL FOOTINGS TO BE PLACED ON FIRM, UNDISTURBED, INORGANIC MATERIAL. PROOF ROLL SUB-GRADE PRIOR TO PLACING CONCRETE WHERE THE MATERIAL HAS BEEN DISTURBED BY EQUIPMENT. UNACCEPTABLE/DISTURBED MATERIAL SHALL BE OVER-EXCAVATED AND REPLACED WITH "LEAN CONCRETE FILL". THE GEOTECHNICAL REPORT SHALL BE REVIEWED AND ADHERED TO FOR SPECIFIC RECOMMENDATIONS. 6.STRUCTURAL BACKFILL SHALL BE GRANULAR FREE-DRAINING MATERIAL FREE OF DEBRIS, ORGANICS, REFUSE AND OTHERWISE DELETERIOUS MATERIALS. MATERIAL SHALL BE PLACED IN LIFTS NO GREATER THAN 6" IN DEPTH AND COMPACTED TO 95% OF MAXIMUM DENSITY AS DETERMINED PER ASTM D1557 (MODIFIED PROCTOR). THE GEOTECHNICAL REPORT SHALL BE REVIEWED AND ADHERED TO FOR SPECIFIC RECOMMENDATIONS. MECHANICAL ANCHOR NOTES: 1.HILTI PRODUCTS MUST BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS, AS INCLUDED IN THE ADHESIVE PACKAGING. 2.CONTRACTOR SHALL AVOID DRILLING HOLES IN VERTICAL/HORIZONTAL REINFORCING BARS. 3.HOLES MUST BE WIRE BRUSHED AND BLASTED WITH COMPRESSED AIR PRIOR TO INSTALLATION. TEMPERATURES/METHODS/WORKING TIME/ETC. ARE TO BE IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS. SOIL NOTES: 1.FOUNDATION DESIGN BASED ON THE PRESUMPTIVE MINIMUM SOIL PARAMETERS IN ACCORDANCE WITH THE IBC, CBC AND TIA. WHEN A SITE SPECIFIC GEOTECHNICAL REPORT IS AVAILABLE, THE CONTRACTOR SHALL ADHERE TO ALL RECOMMENDATIONS PROVIDED THEREIN. 2.ALL FOUNDATIONS TO BE PLACED ON FIRM, UNDISTURBED, INORGANIC MATERIAL. PROOF ROLL SUB-GRADE PRIOR TO PLACING CONCRETE WHERE THE MATERIAL HAS BEEN DISTURBED BY EQUIPMENT. UNACCEPTABLE/DISTURBED MATERIAL SHALL BE OVER-EXCAVATED AND REPLACED WITH STRUCTURAL BACKFILL. 3.STRUCTURAL BACKFILL SHALL BE GRANULAR FREE-DRAINING MATERIAL FREE OF DEBRIS, ORGANICS, REFUSE AND OTHERWISE DELETERIOUS MATERIALS. MATERIAL SHALL BE PLACED IN LIFTS NO GREATER THAN 6" IN DEPTH AND COMPACTED TO 95% OF MAXIMUM DENSITY AS DETERMINED PER ASTM D1557 (MODIFIED PROCTOR). THE GEOTECHNICAL REPORT SHALL BE REVIEWED AND ADHERED TO FOR SPECIFIC RECOMMENDATIONS. ANCHOR FRAME GENERATOR PAD - SECTION A-A SCALE: 1/2" = 1'-0" TYPICAL ANCHOR SCALE: 1/2" = 1'-0" GENERATOR PAD DETAIL #4 U-BARS CONDUIT STUB-UP AREA FLEXIBLE STUB CONDUITS. SEE SHEET E-2. CONCRETE PAD 134" CLR. TYP. LONGITUDINAL TRANSVERSENOTE: PER CBC 1705.12.6, PERIODIC SPECIAL INSPECTION OF ANCHORAGE FOR STANDBY POWER SYSTEMS IS REQUIRED STRUCTURAL DESIGN NOTES: ALL LOADS DERIVED FROM REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE, ASCE 7 & ANSI TIA-222. BUILDING & COMMUNICATION STRUCTURES: (39.506867° / -121.502308°) 1.WIND LOADS: IBC 2018 & ASCE 7-16 V = 94 MPH ULTIMATE WIND SPEED STRUCTURE CLASS = II; EXPOSURE CATEGORY = C; TOPOGRAPHIC CATEGORY = 1. IMPORTANCE FACTOR = 1.0. 2.SEISMIC LOADS: IBC 2018 & ASCE 7-16 STRUCTURE CLASS = II; SITE CLASS = D. SS = 0.634 ; S1 = 0.272 ; SDS = 0.546 GENERATOR PAD DETAILS PO BOX 2621, BOISE, ID 83701 530.539.4787 CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 04/24/20 ISSUED FOR CONSTRUCTION JAD SHEET TITLE: SHEET NUMBER: S-1 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 200 FEET NORTH OF ORO QUINCY HIGHWAY OROVILLE, CA 95966 GENERATOR INSTALLATION PROJECT OLIVE HIGHWAY 10132952 CHECKED BY:GGD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology 09/30/2021 1 05/22/20 ADDED PG&E GROUNDING SPECS JAD (10) XXXXXXXX X X X XXXXXXXX X XXXXXXXXXXXXXXXXXXXXXXXXXXXCHAIN-LINK ACCESS GATE DETAIL (IF REQUIRED) TOP RAIL LINE POST CHAIN-LINK FABRIC MESH WEATHERTIGHT POST CAP, TYP. TENSION BAR, USE (1) FOR EACH END OR GATE POST, (2) FOR EACH CORNER POST END, GATE, CORNER OR PULL POST TENSION BAND, (1) PER FOOT OF FENCE HEIGHT DIAGONAL ROD WITH STEEL TURNBUCKLE ON GATE & ALL CORNERS WITH HORIZONTAL BRACE SEE LINE POST SPACING SCHEDULE SEE LINE POST SPACING SCHEDULE 0'-0"TOP OF CONCRETE LINE POST BOTTOM TENSION WIRE CONCRETE BRACE RAIL BRACE RAIL, EA. CORNER, EA. WAY 6' TO 8' CHAIN-LINK FABRIC2" MAXCLEARANCE FROMGRADE, TYP.CHAIN-LINK GATE/FENCE SPECIFICATIONS: (INSTALL FENCING PER ASTM F567 / SWING GATES PER ASTM F900)NOTES: GATE POST 4.500" O.D. SCHEDULE 40 PIPE FOR GATE WIDTHS UP T0 6 FEET, PER ASTM F1083. POST & FENCE PIPE SIZES ARE FENCE INDUSTRY STANDARD. ALL PIPE TO BE HOT-DIP GALV. CROSS BRACE ALL POSTS EXCEPT INTERMEDIATES. LINE POST 6' TALL = 2.375" O.D. SCHEDULE 40 PIPE PER ASTM F1083. 8' TALL = 2.875" O.D. SCHEDULE 40 PIPE PER ASTM F1083. CORNER POST 3.500" O.D. SCHEDULE 40 PIPE PER ASTM F1083. TOP RAIL/BRACE RAIL 1.875" O.D. SCHEDULE 40 PIPE, PER ASTM F1083. GATE FRAME 1.875" O.D. SCHEDULED 40 PIPE, PER ASTM F1083. GATE LATCH 1.375" O.D. PLUNGER ROD W/ MUSHROOM TYPE CATCH AND LOCK. CONTRACTOR TO INSTALL (2) GATE HOLDBACKS TO HOLD GATE OPEN DURING USE. FABRIC 9 GA. CORE WIRE SIZE 2" MESH, CONFORMING TO ASTM A392. - TIE WIRE MINIMUM 11 GA. GALVANIZED STEEL AT POSTS AND RAILS A SINGLE WRAP OF FABRIC TIE AND AT TENSION WIRE BY HOG RINGS SPACED MAX. 24" INTERVALS. - TENSION WIRE 7 GA. GALVANIZED STEEL.- BARBED WIRE DOUBLE STRAND 12-1/2" O.D. TWISTED WIRE TO MATCH WITH FABRIC 14 GA. 4 PT. BARBS SPACED ON APPROXIMATELY 5" CENTERS. LOCAL ORDINANCE OF BARBED WIRE PERMIT REQUIREMENTS SHALL BE COMPLIED WITH IF REQUIRED. CHAIN-LINK FENCE DETAIL #2 SOLID, TINNED BARE COPPER WIRE CADWELD CORNER POSTS TO GROUND RING GROUND RING GATE FRAME TENSION BAR, USE (1) FOR EACH GATE POST "STYMIE LOCK" ASSEMBLY PLUNGER BAR DIAGONAL ROD WITH STEEL TURNBUCKLE ON GATE & ALL CORNERS WITH HORIZONTAL BRACE FOOTPAD, TYP. CHAIN-LINK FABRIC MESH SEE PLANS SHEET 6' TO 8' CHAIN-LINK FABRIC2"0'-0"TOP OF CONCRETE CHAIN-LINK FENCE SECURITY TOPPER HSS2x2x14 TUBE, SECURITY TOPPER BEAM 12"Ø A325 BOLT W/ NUT & LOCKWASHER L5x3x14 LEDGER (2) 12"Ø U-BOLTS FENCE POST A-A TYPICAL POST CONNECTION 14GA BRAIDED GROUND (POST TO GATE FRAME), TYP. #2 SOLID, TINNED BARE COPPER WIRE CADWELD POST TO GROUND RING, TYP. GROUND RING CONCRETE FOOTPAD, TYP. ⅊34x7x7 (4) 12"Ø x 3.5" EMBED HILTI KWIK BOLT TZ STAINLESS STEEL EXPANSION ANCHOR (OR APPROVED EQUAL). REFERENCE ICC-ES ESR-1917 REPORT. 3.5" 3/16 POST LINE POST FOOTPAD DETAIL 1" DRY PACK, IF REQ'D 5"3"(MIN.) TO EDGE OF SLAB ⅊34x9x9 (4) 12"Ø x 3.5" EMBED HILTI KWIK BOLT TZ STAINLESS STEEL EXPANSION ANCHOR (OR APPROVED EQUAL). REFERENCE ICC-ES ESR-1917 REPORT. 3.5" 3/16 POST GATE/CORNER POST FOOTPAD DETAIL 1" DRY PACK, IF REQ'D 7"3"(MIN.) TO EDGE OF SLAB SEE LINE POST SPACING SCHEDULE LINE POST SPACING SCHEDULE: DESCRIPTION MAXIMUM SPACING 6' TALL MESH ONLY 4'-0" 8' TALL MESH ONLY 3'-0" CHAIN-LINK MAN GATE DETAIL GATE FRAME TENSION BAR, USE (1) FOR EACH GATE POST DIAGONAL ROD WITH STEEL TURNBUCKLE ON GATE & ALL CORNERS WITH HORIZONTAL BRACE CHAIN-LINK FABRIC MESH 6' TO 8' CHAIN-LINK FABRIC0'-0" 14GA BRAIDED GROUND (POST TO GATE FRAME), TYP. GATE LATCH W/ PADLOCK #2 SOLID, TINNED BARE COPPER WIRE CADWELD POST TO GROUND RING, TYP. GROUND RING TOP OF CONCRETE SEE PLANS SHEET FENCE & GATE DETAILS PO BOX 2621, BOISE, ID 83701 530.539.4787 CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 04/24/20 ISSUED FOR CONSTRUCTION JAD SHEET TITLE: SHEET NUMBER: S-3 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 200 FEET NORTH OF ORO QUINCY HIGHWAY OROVILLE, CA 95966 GENERATOR INSTALLATION PROJECT OLIVE HIGHWAY 10132952 CHECKED BY:GGD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology 09/30/2021 1 05/22/20 ADDED PG&E GROUNDING SPECS JAD CONTRACTOR TO COVER ANY GAP BETWEEN THE 6' FENCE & 8' FENCE WITH A 2' FENCE SECTION AS REQUIRED (CHAIN-LINK IS NOT REQUIRED BELOW THE GAP) AA CHAIN-LINK MESH, TYP. LEDGER, TYP. CONNECT TO EACH POST3'-0"MAX.A A OVERLAP MESH & SECURE LEDGER, TYP. CONNECT TO EACH POST NOTE: CONTRACTOR TO CUT HOLES IN MESH FOR GENERATOR VENT PIPES AS REQUIRED OVERLAP MESH & SECURE 3'-0"MAX.SPAN CHAIN-LINK FABRIC MESH ACROSS HSS BEAMS, ADEQUATELY TENSION FABRIC, AND SECURE TO EACH TOPPER BEAM (10) SECURITY TOPPER BEAMS REQUIRED FOR COMPOUND (7) SECURITY TOPPER BEAMS REQUIRED FOR EXPANSION INSTALL TENSION BAR AND TENSION BANDS AT EACH END SIMILAR TO FENCE CORNER DETAIL CONTRACTOR TO INSTALL STEEL PLATE "GATE STOP" ON INSIDE FACE OF GATE FRAME TO ENSURE GATE IS NOT ALLOWED TO OPEN OUTSIDE OF THE COMPOUND. ⅊12"x6"x12" w/ (2) 12"Ø U-BOLTS TO VERTICAL GATE FRAME MEMBER AS SHOWN 112"3"112"GATE FRAME VERT. FENCE END POST PG&E GROUNDING SPECIFICATIONS PO BOX 2621, BOISE, ID 83701 530.539.4787 CONTACT@GEOSTRUCTURAL.COM WWW.GEOSTRUCTURAL.COM 0 04/24/20 ISSUED FOR CONSTRUCTION JAD SHEET TITLE: SHEET NUMBER: E-3.1 REV DATE DESCRIPTION INT REVISIONS SITE INFORMATION: 200 FEET NORTH OF ORO QUINCY HIGHWAY OROVILLE, CA 95966 GENERATOR INSTALLATION PROJECT OLIVE HIGHWAY 10132952 CHECKED BY:GGD THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMES IS STRICTLY PROHIBITED. at t & GENERAL DYNAMICS Information Technology 09/30/2021 1 05/22/20 ADDED PG&E GROUNDING SPECS JAD FOR INFORMATION ONLY