Loading...
HomeMy WebLinkAboutB19-3621 SITE PLAN REVISED 8.12.202019'-2" 1 111 LHDesignsHomes.comLHDesignsHomes.comSheet Title: Client Address: Job Site Location: www.LHdesignsHomes.com Sheet Number: Authorization By: Project Information: Signature only by: Jason Liebgott ALL IDEAS, DESIGNS AND PLANS REPRESENTED BY THIS DRAWING ARE THE EXCLUSIVE PROPERTY OF LH DESIGNS AND SHALL NOT BE REPRODUCED WITHOUT PRIOR WRITTEN PERMISSION. ANY UNAUTHORIZED REUSE OF THIS DRAWING SHEET OTHER THAN FOR THE PROJECT AND LOCATION SHOWN IS PROHIBITED. 16 Patches Drive Chico,CA 95928 (530) 891-1889 LH Designs Residential Plans & Design Consulting C.S. Cover Sheet NEW PROPANETANKO.H. PowerLine NewPROPOSEDRESIDENCE PROPANE TANK Weeds, grass, brush,trash and other combustible materialsshall be kept a minimum of 10 feet fromLP-gas tanks or Containers.SEPTIC TANKAND LEACH LINES(BY OTHERS)ReplacementLeach Field 5' min.BUILDING SETBACKS: ZONE AG-2FRONT= 20' From Property LineSIDE= 5'REAR= 10'NEW WELLAND PUMP HOUSE (By Others) 100' R A D. S E P TIC F R E E NEWSERVICE PANELMETER/MAIN NEWDRIVEWAY 265'257'U .G . P o w e rLine N e w 133'130'56'105'90'30'Future PoolArea16'x40' PROPOSED NEW (4) BD RM SEPTIC TANKAND LEACH LINES (BY OTHERS)5' min. PROPOSED NEW WELL (By Others) 100' R A D. S E P TIC F R E EFUTURE Proposed 22x34 SHOP AREAPROPOSED RESIDENCE Patio Area GarageArea CoveredPatio Area CoveredPorch Area Entry TrashAreaConcreteParking &Turn Around 75'50'Future ProposedTennis Court12'55'23' 44'Dri vewayDriveway 257'Void PRELIMINARY SETSUBMITTAL SET Void PRELIMINARY SETSUBMITTAL SET SUBMITTAL SET Project Description: Main Residence- Number of Stories: Fire Sprinklers: Year Built: Occupancy Class: Building Use: Code Analysis- Applicable Codes: Construction Type:V-B Project Information: (1) Required (By Others) N/A R-3/U Residence 1. Please see Sheet T1.0 and T-24 Report (By Others) for any, mechanical equipment, insulation values, Special Energy Features or HERs Requirements, Per Certificate of Compliance, form CF-1R. 2. Air retarding wrap and radiant barrier to be installed as noted on the Title 24 Energy Calculations.(See plans for required locations of installation.) Requirements "Special Feature” 2016 C.R.C., 2016 C.M.C., 2016 C.E.C., 2016 C.G.C., 2016 C.P.C., 2016 C.B.C. (Structural),NProposed Site Plan Scale: 1" = 10' TRUSS PLAN BY: SYSTEMS PLUS LUMBER COMPANY (530)-378-6800 Design Team: ARCH. PLANS BY: LH DESIGNS (530)-891-1889 3. Project will require compliance with California Senate Bill 407 for the installation of water-conserving fixtures. 2016 California Energy Code, and 2016 California Fire Code. SITE NOTES: 1.) Gate entrances shall be at least two feet wider than the width of the traffic lane and at least 30 feet from the roadway and shall open to allow a vehicle to stop with out obstructing traffic on that road. 2.) Size of letters, numbers and symbols for addresses shall be a minimum 3 inch letter height, 3/8 inch stroke, reflectorized, contrasting with the background color of the sign Installation, Location and Visibility of Addresses. All buildings shall have a permanently posted address, which shall be placed at each driveway entrance and visible from both directions of travel along the road. In all cases, the address shall be posted at the beginning of construction and shall be maintained thereafter. 3.) When Fire Sprinklers are required, three (3) sets of sprinkler plans with flow calculations shall be submitted to Butte County Fire Department for review prior to the start of construction. Sprinkler plans and calculations shall be done by a Licensed C-16 contractor. 4. An automatic fire sprinkler system shall be installed in accordance with Section R313 of the 2016 C.R.C. (By Others). (The automatic sprinkler system is to be designed under a separate permit.) 5. A minimum 65 percent of the non-hazardous construction and demolition waste shall be recycled and/or salvaged for reuse in accordance with the California Green Building Standards Code, Chapter 4, Division 4.4 [CRC R334.1]. STRUCT. PLANS AND ENGINEERING BY: STREAMLINE ENGINEERING (530)-892-1100 T-24 REPORT BY: NORCAL GREEN BUILDING CONSULTING (530)-321-7812 PROPOSED RESIDENCE Gravel Driveway (By Others) 1,200 SQ. FT. 1,503 Sq Ft 2,175 Sq Ft Total Living Garage Covered Porch Total Area SQ. FT. FIGURES 192 Sq Ft 480 Sq Ft 1 MINIMUM EROSION AND SEDIMENT CONTROLS FOR PROJECTS DISTURBING LESS THAN ONE ACRE The BMP's (Best Management Practices) listed below must be in place during time of construction. The BMP's listed are minimum requirements and additional BMP's could be required based Stabilized entry: Provide minimum 3" to 6" fractured rock 50' long x 15' wide by 6" deep over construction grade fabric. All soils tracked onto paved roadways must be cleaned up on a daily basis. When streets are wet or during a rain event there shall be no tracking of soils onto the street. Wattles installed properly behind curb or sidewalks. Rock bags (minimum 2 per side) at all drain inlet locations within 150' of the project site. Internal filters placed inside each drain inlet. Trash bars across the back of all drain inlets. Stabilize all disturbed soils in the front yard areas within 15' of the back of curb or sidewalk. (Straw or erosion blankets may be used for this application). Stabilize all slopes where erosion could occur and cause silt run off. (Straw, visqueen or erosion blankets may be used for this application). All paint, fuel, construction products etc. shall be stored in a covered location away from sidewalks and storm drain inlets. Portable chemical toilets if provided on the site must be kept off of streets and sidewalks and at least 50' from the nearest storm drain inlet. All trash must be collected and stored properly. Do not let items such as drywall mud boxes, paint buckets, cleaning material containers etc. come in contact with any rainfall or storm water runoff. Provide a designated area for concrete washout. Hay bales lined with visqueen may be used for this application. Rollaway bins may also be used. All concrete washout systems shall be placed off of the paved streets. STORM WATER DRAINAGE AND RETENTION DURING CONSTRUCTION AND SURFACE DRAINAGE PLAN TO BE SITE/LOT SPECIFIC. A PLAN SHALL BE SUBMITTED WITH EACH PERMIT APPLICATION AND REVIEW PRIOR TO ISSUANCE. REFER TO 2016 CGBSC SECTIONS 4.106 SITE DEVELOPMENT. * * * * * * * * * * * * on site conditions. 1)THIS PROJECT IS LOCATED IN A WILDLAND-URBAN INTERFACE FIRE AREA AS DEFINED IN SECTION 702A AND SHALL COMPLY WITH ALL THE SECTIONS OF THIS CHAPTER. 2) FIRE SPRINKLERS TO BE INSTALLED IN THE PROPOSED STRUCTURE BEING BUILT. FIRE SPRINKLERS TO BE REVIEWED AND APPROVED UNDER A SEPARATE PERMIT. (BY OTHERS) 3) ALL VENTS MUST BE APPROVED BY LOCAL OR STATE FIRE MARSHAL. 4) Exterior glazing in accordance with CRC R337.8.2.1. One pane of window shall also be tempered. Revise floor plan as necessary to indicate this requirement. 5) Fire resistive exterior doors in accordance. The door exterior surface shall be of noncombustible or ignition-resistant materials or be constructed of solid core wood 1-3/8” thick or have a fire-resistive rating of not less than 20-minutes. [CRC R337.8.3]. 6) Ignition resistant or non-combustible eaves and soffits. Open Roof Eaves require noncombustible or ignition-resistant materials. Provide manufacturer’s documentation. [CRC R337.7.5]. 7) Attic vents and foundation vents shall be fully covered with metal wire mesh or noncombustible materials with minimum of 1/16” and shall not exceed 1/8” openings. 8) Roof Gutters shall be provided with means to prevent the accumulation of leaves and debris in the gutter. [CRC R337.5.4]. 9)Approved eave vents that resist the intrusion of flame and burning embers. [CRC R337.6.3 Exception #1]. WILDLAND-URBAN FIRE NOTES: 13884 Olivet Dr. 95 '130'BUILDING SETBACKS: RR-5 FRONT= 20' SIDE= 10' REAR= 10' 20' Front Building Setback Line Driveway(By Others)10' Side Building Setback Line140'(N) ELECT. SERVICE PANEL PER PLAN FIELD VERIFY (E) SEPTIC TANK AND LEACH LINES 150' (BY OTHERS)Beach Residence9992 Blackwell Rd.Central Point, OR. 9750213884 Olivet Dr.Magalia, CA. 95954APN# 064-240-02810' EASEMENT PUE7 0' Proposed project is for a new three bedroom residence. Total living area is 1,503 sq. Also proposed is a new driveway area (By Others). Please see plans for more information. 10' 10'5'MIN.78'Covered Porch Area 192 SQ. FT. ReplacementLeach Field Garage Area Patio Area 322 SQ. FT. NEW ABOVE GROUND 250 GAL PROPANE TANK PROPANE TANK Weeds, grass, brush, trash and other combustible materials shall be kept a minimum of 10 feet from LP-gas tanks or Containers.39'10' Side Building Setback Line10' Rear Building Setback Line 12' LOT AREA: .25 ACRE or 10,890 SQ FT. 480 Sq Ft 1,503 Sq Ft 1 Drafting By: JL Job Name: Beach Job# 1926 Date 8-12-20 Rev# 03 1 Plan Check Date 3-5-20 1 Project Disclaimer: No Liability is assumed for the accuracy of the following data. In the production of these plans LH Designs has made every attempt to avoid mistakes, however we cannot guarantee against human error. It is the responsibility of the contractor to examine all dimensions, elevations and quantities. The contractor is responsible for doing so prior to beginning construction. In the event that variations in the practices of contractors arise, the builder is to assume responsibility for materials. Variance in climatic conditions, hardware requirements, and local building and agency codes fall to the responsibility of the builder as well. These plans are provided without warranty of any kind, spoken or implied, including and warranties of the selling value and/or condition of the plans for a specific purpose. LH Designs and the drafter are not liable for damages, direct or indirect, that may arise from the non-success of a design. LH Designs and the drafter shall not be liable for any injury to any person or any property that occur, directly or indirectly, from these plans. In no event are LH Designs to be held liable to you for any damages, including lost profits or assets, incidental or consequential, that may come out of your inability to use these plans. In addition, LH Designs and the drafter are not liable for any claim by any other party. Written Dimensions Shall have precedence over scale dimensions. Contractors must be responsible for dimensions and conditions of the job. LH Designs must be notified of any variations from the dimensions and conditions of these plans. Every permit issued shall become invalid unless the work authorized by such permit is commenced within 180 days after its issuance or after commencement of work if more than 180 days pass between inspections. The building official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. R105.5 Expiration. ReplacementLeach Field 32' 35' 14' 14' 20' 20' 10' 10'