Loading...
HomeMy WebLinkAboutFAI15-0052 CF 2020 CAL Butte County Fire Department FIRE coy Fire Prevention B u re a u moll ooh NOV 176 Nelson Avenue Oroville, CA 95965 HESB�E Office (530)538-7888 Butte County • www.buttecounty.net/fire ""F°R"'A FIRE SAFETY CORRECTION NOTICE FILE NUMBER PAGE OF PAGE FAI15-0052 1 12 NAME HOURS MINUTES Butte Community College ADDRESS 3536 Butte Campus Drive, Oroville, CA 95965, (530) 895-2511 THE CALIFORNIA HEALTH AND SAFETY CODE AND THE STATE FIRE MARSHAL'S REGULATIONS REQUIRE THE FOLLOWING FIRE SAFETY DEFICIENCIES BE CORRECTED: Project Information A required Fire Life and Safety inspection pursuant to Health and Safety Code § 13146.3 was conducted at the above facility from July 28, 2020 to August 2, 2020. Due to the size of the campus and duration of inspection I was unaccompanied, however contact was made prior to inspection with Mark Allen, Facilities, 530-624-4199. Inspection The inspection consisted of the entire campus including; Public Safety Training Grounds (PSTG), Welding Manufacturing (WM), Facilities Planning Management (FPM), Recycling Center, Physical Education (GYM), Mens Locker Room (MLR), Womens Locker Rooms (WLR), Field House (KAP), Arts (ARTS), Student Health Clinic (SHC), Swing Space A (SSA), Swing Space C (SSC), Swing Space F (SSF), Swing Space G (SSG), Regional Testing Center (RTC), Business Education (BE), Student Administration Services (SAS), Campus Center (CC), Allied Health/Public Service Center (AHPS), Library (LB), Media Center (MC), Learning Resource Center (LRC), Life Science (LS), Automotive Technology (AT), Physical Science (PS), Ag Storage, Mechanized Ag (MA), Ag Repair Shop, Horticulture Storage, Green Houses, Environmental Horticulture (EH), and Child Development Center (CDC). During the inspection the following deficiencies were noted. Deficiencies WM at Exterior Gas Storage Area Extension cord use. Remove cord or provide permanent wiring. CFC 605.5 WM 128 Remove items blocking electrical panels and maintain access. CFC 605.5 `1 F1 I WM North Welding Shop between Booth 30 and 31 Open electrical junction box, provide cover plate. CFC 605.6 �a ,- WM Exterior Breezeway at Panel HPZ Remove items blocking electrical panels and maintain access. CFC 605.5 ' 3 pi;ro',00 } N. ill 41... , cow WM Various locations,Oily Rag Bins Empty oily rag containers daily. CCR,T19, Div. 1, §3.19 (2) (c) ,:rr iirr ler ark WM Exterior FDC FDC is missing caps. Provide caps as noted in Voltage Specialist's discrepancy report from 6-9-20. FPM at Pete Huru's Office Exit sign is non operative. Repair or replace sign. CFC 1104.5 Gym 118 Extension cord use. Remove cord or provide permanent wiring. CFC 605.5 400 Gym 122 Electrical Panel 1LA, missing blank cover plate, provide cover plate. CFC 605.6 .r EngJ 1E1 e Gym Fire Sprinkler System Replace automatic fire sprinkler system inspector test valve as noted in Voltage Specialist's discrepancy report from 6-9-20. MLR 102 Fire Extinguisher is mounted too high.Top of extinguisher cannot be above 5'from floor. iIt 1 — IlMI MLR 102 Ladders are blocking fire extinguisher access, remove ladders. CFC 906.6 i In I, .1 ti, \Ili i 1 4'lit - . , 1 4. 'r.„t---,. . lifi OSI MLR at MLR 107 Exit sign is damaged. Repair or replace sign. CFC 1104.5 w. alli v- 1 1 WLR South Wall at Restroom Emergency Lighting is non-operational. Repair or replace lighting. CFC 1008 and 1104.5 WLR at WLR 115 Emergency Lighting is non-operational. Repair or replace lighting. CFC 1008 and 1104.5 WLR at WLR 117 Emergency Lighting is non-operational. Repair or replace lighting. CFC 1008 and 1104.5 KAPC 203 Exit Sign and Emergency Lighting are non-operational. Repair or replace lighting. CFC 1008 and 1104.5 KAPC 204 Exit Sign and Emergency Lighting are non-operational. Repair or replace lighting. CFC 1008 and 1104.5 KAPC 209 Exit Sign and Emergency Lighting are non-operational. Repair or replace lighting. CFC 1008 and 1104.5 KAPC 214 Exit Sign and Emergency Lighting are non-operational. Repair or replace lighting. CFC 1008 and 1104.5 KAPC 215 Exit Sign and Emergency Lighting are non-operational. Repair or replace lighting. CFC 1008 and 1104.5 KAPC 216 Exit Sign and Emergency Lighting are non-operational. Repair or replace lighting. CFC 1008 and 1104.5 ARTS 166 At door 166-1, adjust door so that it opens smoothly,and does not contact floor. CFC 1031.2 KAPC Exterior FDC Remove one of the FDC connectors and provide FDC caps as noted in Voltage Specialist's discrepancy report from 6-9-20. ARTS 205 Extension cord use. Remove extension cord or provide permanent wiring. CFC 605.5 SSA 102 Exit door at northeast corner, adjust door so that it opens smoothly. CFC 1031.2 A* K ' hr SAS 152 Items blocking fire extinguisher access, remove items, maintain access. CFC 906.6 Vey 1 CC at Cafeteria Check Stand Emergency Lighting is non-operational. Repair or replace lighting. CFC 1008 and 1104.5 CC 212.1 Fire Extinguisher not mounted. Mount Fire Extinguisher. CFC 906.7 CC, Bookstore, Store room Extension cord use. Remove extension cord or provide permanent wiring. CFC 605.5 and 605.9.1 _� 1 �� Or I 1 .111 ! _II ii III 11 l �`r ' it illF, 5, CC, Book Store, Beverage Display at West Register Emergency Lighting is non-operational. Repair or replace lighting. CFC 1008 and 1104.5 CC, Bookstore, East Register Emergency Lighting is non-operational. Repair or replace lighting. CFC 1008 and 1104.5 CC, Bookstore, North Wall Emergency Lighting is non-operational. Repair or replace lighting. CFC 1008 and 1104.5 CC 108.1 Extension cord use. Remove extension cord or provide permanent wiring. CFC 605.5 and 605.9.1 CC, First Floor,West side at Stair and Water Fountain Emergency Lighting is non-operational. Repair or replace lighting. CFC 1008 and 1104.5 CC, Bookstore/Lounge Area,South side Emergency Lighting is non-operational. Repair or replace lighting. CFC 1008 and 1104.5 CC, Bookstore Emergency Lighting is non-operational. Repair or replace lighting. CFC 1008 and 1104.5 CC, Bookstore, First Floor at East side Emergency Lighting is non-operational. Repair or replace lighting. CFC 1008 and 1104.5 LB 103 Missing ceiling tile. Replace tile. CFC 703.1 e LB 207 Custodian Room Emergency Lighting is non-operational. Repair or replace lighting. CFC 1008 and 1104.5 LB 210 Extension cord use. Remove extension cord or provide permanent wiring. CFC 605.5 0Y r. Elia** \-, LB 221 Fire Extinguisher not mounted. Mount Fire Extinguisher. CFC 906.7 LB 308 Emergency Lighting is non-operational. Repair or replace lighting. CFC 1008 and 1104.5 LB Replace missing sprinkler escutcheons in 3rd floor gender RR, 2nd floor AC room, Room 216, and in Room 104 as noted in Voltage Specialist's discrepancy report from 6-9-20. TE 105 A/B Hall Emergency Lighting is non-operational. Repair or replace lighting. CFC 1008 and 1104.5 Missing ceiling tile. Replace tile. CFC 703.1 a� t S AHPS 166 at South Door Emergency Lighting is non-operational. Repair or replace lighting. CFC 1008 and 1104.5 AHPS 227 Hole in ceiling. Repair hole. CFC 703.1 BE 107 Exit Sign and Emergency Lighting are non-operational. Repair or replace lighting. CFC 1008 and 1104.5 BE 115 Emergency Lighting is non-operational. Repair or replace lighting. CFC 1008 and 1104.5 BE 115 Replace ceiling tile, open electrical junction box, provide coverplate. CFC 703.1 and 605.6 11111 BE 129 Fire Extinguisher is mounted too high.Top of extinguisher cannot be above 5'from floor. CCR, T19, Div. 1, §567.4 BE 136 Emergency Lighting is non-operational. Repair or replace lighting. CFC 1008 and 1104.5 Emergency Exit is blocked. Remove obstructions. 40. ad CDC Lady Bugs Room Remove Fabric covering at ceiling or provide documentation that fabric meets CFC Chapter 8 and CCR T19. Div.1 requirements or has been treated with a fire retardant coating. CFC 803.4 CDC Catepillar Room Remove Fabric covering at ceiling or provide documentation that fabric meets CFC Chapter 8 and CCR T19. Div.1 requirements or has been treated with a fire retardant coating. CFC 803.4 .411`. �I A A �. CDC Butterflies Room Remove Fabric covering at ceiling or provide documentation that fabric meets CFC Chapter 8 and CCR T19. Div.1 requirements or has been treated with a fire retardant coating. CFC 803.4 ` -4010- CDC `CDC Bumblebee Room Remove Fabric covering at ceiling or provide documentation that fabric meets CFC Chapter 8 and CCR T19. Div.1 requirements or has been treated with a fire retardant coating. CFC 803.4 LRC First Floor West Entry Open electrical junction box, provide cover plate. CFC 605.6 LS 105 Emergency Lighting is non-operational. Repair or replace lighting. CFC 1008 and 1104.5 LS Lab Area Across from 123 A Emergency Lighting is non-operational. Repair or replace lighting. CFC 1008 and 1104.5 LS 111 Emergency Lighting is non-operational. Repair or replace lighting. CFC 1008 and 1104.5 Items Discussed/Requested After the inspection, discussed with Mark Allen general fire safety practices and procedures. Forwarded a copy of the report on 8-15-20 via email to Mark Allen. ISSUED BY(DEPUTY FIRE MARSHAL) RECEIVED BY DATE Mark Allen Christopher Boyd Email: allenmar@butte.edu 8-15-2020 Please provide the following; Fire Extinguisher-Monthly Inspection Logs for 2020, Annual maintenance report Automatic Fire Sprinkler Systems-Annual testing, inspection and maintenance reports Alternative Automatic Extinguishing Systems-Testing, inspection and maintenance reports for CC Kitchen (ANSUL) and TE and AHPS South (FM 200). Fire Alarm Systems-Annual testing, inspection and maintenance reports for all buildings. Overhead Fire Doors and Curtains- Provide documentation of annual testing and maintenance.These operational tests can be performed by Butte College Maintenance personnel.