HomeMy WebLinkAboutFAI15-0049 CF Alarm Test 2020 ALARM AND DETECTION REPORT Page 1 of 4 6*'tc-1 iU--0(o a cp! rC-00 VObTAGE\SPECIALIsTs 530-624-4514 C10/C16 License#880862 www.VoitageSpeciaiists.com Inspection # 1-001 ALARM & DETECTION EQUIPMENT TEST REPORT Type of Inspection:ANNUAL Date: 2/24/20 Customer DURHAM USD Site: DURHAM ELEMENTARY SCHOOL Street: 9421 PUTNEY DRIVE Contact: Eric City/State: DURHAM, CA Phone#: 530-514-4604 Fax#: 1. Before Test Notify Proper Authorities: Name Phone# A. Owner or Owner's Rep Eric 530-514-4604 B. Fire Department CAL FIRE 530-891-2788 C. Central Station NA D. Central Station Acct# NA 2. Control Panel Status Yes No Note# A. Is the system monitored by Central Station? I X On Test Time: 6:00 Return to Service Time: 10:00 B. Is the Power Light on? X C. Does the Panel indicate Normal conditions? X D. Are all indicating Lamp Bulbs in Operator order? X E. Does the Trouble Light operate? X F. Does the Silence Switch Operate? X G. Battery A.H.18 Date Batteries Installed: 12/20/18 H. Does the Panel have Non-Operational Zones? X I. Does the Panel have Battery Backup? X J. Do the batteries indicate they are Properly Charged? X Condition of Batteries: Good Note# Battery Voltage with AC Power: 27.21 Battery Voltage without AC Power: 26.80 K. List any trouble conditions on panel before test: Note# Note# Comments: Note# Note# 3. FACP Manufacturer: SIMPLEX Model# 4020 System Type: ADDRESSAB Location of Annunciators: MAIN OFFICE Location of Primary Power Source: Panel# Breaker Comments: Note# Note# FCPS: Manufacturer: SIMPLEX Model# 4009 Panel/Breaker# Location:BY FACP Battery Voltage with NC Power: 27.98 w/o NC Power 27.52 Date: 12/21/18 FCPS: Manufacturer: SIMPLEX Model# 4009 Panel/Breaker# Location:BY FACP Battery Voltage with A/C Power: 27.94 w/o A/C Power P7.65 Date: 12/21/18 FCPS: Manufacturer: Model# Panel/Breaker# Location: Battery Voltage with A/C Power: w/o A/C Power Date: Owner/Rep: Phone#: Date: Inspector: Mat Machado Phone#: 530-362-2609 Date:2/24/20 Owners Rep Sign: Date:2/24/20 Inspector Sign: ALARM AND DETECTION REPORT Page 2 of 4 _ Pro ert Site : DURHAM ELEMENTARY SCHOOL p Y Operational # Tested This Equipment Total # Report Yes N/A Note # I4. Remote Annunciators 1 1 X I5. Zones 6. Manual Stations (Pull) Hardwire Addressable 27 27 X 7. Detectors Photoelectric 1 1 X Ionization Heats / Fixed or R of R Flame Duct (See #15) 8. Horn / Strobe 39 39 X Strobe Orly 14 14 X Bell Speakers Horn 8 8 X 9. 10. Automatic Door Release X 11 . Water Flow switches X Did W/F Ring Outside Bell? X Did W/F Activate Alarm Panel? X 12. Tamper Switches X 13. PIV X OS & Y X 14. 15. Did test of Duct Detectors shut down air handling units? X 16. Did the Monitoring Center (Fire Dept, Central Station, Lease Line) receive signal? X 17. Is system reset for normal conditions? X 18. Is system restored to operational service? X 19. Have Proper Authorities (see #1 ) been notified system is back in service? X List Proper Authorities: Cal Fire 20. Indicate % of equipment tested this report 25% 50% 75% Vf100% 21 . Indicate % of equipment tested YTD 25% 50% 75% V 100% Comments for any "no" answers or explanations (Note #): 2/24/20 Owners Rep Sign: Date: Inspector Sign: ALARM AND DETECTION REPORT Page 3 4 of Property Site: DURHAM ELEMENTARY SCHOOL DEVICE zoo o.SLC DEVICE TYPE DEVICE LOCATION PASS FAIL NOTE# CHANNEL N PS SOUTH WEST MAIN HALL X 1 1 PS SOUTH MAIN HALL X 1 2 PS KITCHEN X 1 3 PS MULTI PURPOSE X 1 4 PS MULTI PURPOSE X 1 5 PS SOUTH WEST COURTYARD X 1 6 PS LIBRARY X 1 7 PS NORTH WEST COURTYARD X 1 8 PS NORTH WEST MAIN HALL X 1 9 PS NORTH MAIN HALL X 1 10 PS MAIN EAST ENTRANCE X 1 11 PS ROOM 32 NORTH X 1 12 PS ROOM 32 SOUTH X 1 13 PS ROOM 31 NORTH X 1 14 PS ROOM 31 SOUTH X 1 15 PS ROOM 30 X 1 16 PS ROOM 29 X 1 17 PS ROOM 40 X 1 18 PS ROOM 39 X 1 19 PS ROOM 38 X 1 20 PS ROOM 37 X 1 21 PS ROOM 36 X 1 22 PS ROOM 35 X 1 23 PS ROOM 34 X 1 24 PS ROOM 33 X 1 25 PS ROOM 41 X 1 27 PS ROOM 42 X 1 28 PSD ABOVE FACP X 1 26 Owners Rep Sign: Date: 2/24/20 Inspector Si 660U ALARM AND DETECTION REPORT DURHAM ELEMENTARY SCHOOL Page 4 of 4 Zone or DEVICE DEVICE SLC # TYPE DEVICE LOCATION PASS FAIL NOTE # CHANNEL LEGEND PSD—Photoelectric Smoke Detector BD—Beam Detector H—Horn V—Visual ISD—Ionization Smoke Detector PS—Pull Station WPH—Weather Proof Horn TS—Tamper Switch PDD —Photo Duct Smoke Detector RR—Rate of Rise Heat Detector C—Chime WF—Water Flow Switch IDD —Ion Duct Smoke Detector HT—Fixed Temp Heat Detector CV—Chime Visual DH—Door Holder DHS—Door Holder & Smoke Detector FD —Flame Detector S—Speaker OSY—Outside Stem &Yoke Tamper Valve SSD—Signal Station Smoke Detector R—RPII AV—Audible Visual PIV—Pnct lnriirator Valve Cur - Elevator Curtains FRD - Fire Rolldown Door SDC Smoke Detector & Door Holder Combo CO - Carbon Monoxide Detector - - NOTE # COMMENT 2/24/20 C6VIRI Owners Rep Sign: Date: Inspector Sign: _ 5f, Y4°V