HomeMy WebLinkAboutFAI15-0073 CF Alarm Test 2020 FI(�I 1C-4°-13
ALARM AND DETECTION REPORT 1 4
OLIO-1 —0(0Z— Page of
VObTAGEtSPECIALISTS
530-624-4514
ctoic16 License#880862 www.Vortagespeciarists.com Inspection # 1-276
ALARM & DETECTION EQUIPMENT TEST REPORT
Type of Inspection:ANNUAL Date: 2/24/20
Customer DURHAM USD
Site: DURHAM INTERMEDIATE SCHOOL
Street: 5416 PUTNEY DRIVE Contact: Eric
City/State: DURHAM, CA Phone #: 530-519-4604
Fax#:
- 1. Before Test Notify Proper Authorities: Name Phone #
A. Owner or Owner's Rep Eric 530-519-4604
B. Fire Department CAL FIRE 530-891-2788
C. Central Station NA
D. Central Station Acct# NA
2. Control Panel Status Yes No Note #
A. Is the system monitored by Central Station? I X
On Test Time: 2:00 Return to Service Time: 6:00
B. Is the Power Light on? X
C. Does the Panel indicate Normal conditions? X
D. Are all indicating Lamp Bulbs in Operator order? X
E. Does the Trouble Light operate? X
F. Does the Silence Switch Operate? X
G. Battery A.H.18 Date Batteries Installed: 08/30/16
H. Does the Panel have Non-Operational Zones? X
I. Does the Panel have Battery Backup? X
J. Do the batteries indicate they are Properly Charged? X
Condition of Batteries: Good Note#
Battery Voltage with AC Power: 27.88 • Battery Voltage without AC Power: 27.53
K. List any trouble conditions on panel before test: Note#
Note#
Comments: Note#
Note#
3. FACP Manufacturer: SIMPLEX Model# 4020 System Type: ADDRESSAB
Location of Annunciators: MAIN OFFICE
Location of Primary Power Source:BREAK ROOM Panel# F Breaker 14
Comments: Note#
Note#
FCPS: Manufacturer: SIMPLEX Model# 4009 Panel/Breaker#
F-14 Location:BREAK ROOM
Battery Voltage with A/C Power: 27.11 w/o A/C Power 26.88 Date: 8/30/16
FCPS: Manufacturer: SIMPLEX Model# 4009 Panel/Breaker# Location:BREAK ROOM
F-14
Battery Voltage with A/C Power: 27.55 w/o A/C Power 27.25 Date: 8/30/16
FCPS: Manufacturer: Model# Panel/Breaker# Location:
Battery Voltage with A/C Power: w/o A/C Power Date:
Owner/Rep: Phone#: Date:
Inspector: Mat Machado Phone#: 530-828-3276 Date:2/24/20
Owners Rep Sign: Date:2/24/20 Inspector Sign: ,,,�'IA�•
ALARM AND DETECTION REPORT Page 2 of 4
Property Site: DURHAM INTERMEDIATE SCHOOL
Operational
#Tested
This
Equipment Total# Report Yes N/A Note#
4. Remote Annunciators 1 1 X
5. Zones I
6. Manual Stations (Pull) I
Hardwire
Addressable 22 22 X •
7. Detectors I
Photoelectric 1 I 1 X
Ionization I
Heats/Fixed or R of R I
Flame I
Duct(See#15) I
8. Horn/Strobe 19 I 19 X
Strobe Only 9 I 9 X
Bell I I
Speakers I
Horn 4 I 4 X 1
I I
I I I I I
9. I !
10. Automatic Door Release I I X
11. Water Flow switches I I X
Did W/F Ring Outside Bell? I X
Did W/F Activate Alarm Panel? I I X
12. Tamper Switches I I X
13. PIV I I X
OS &Y I I I X
14. I
15. Did test of Duct Detectors shut down air handling units? I X
16. Did the Monitoring Center(Fire Dept, Central Station, Lease Line)receive signal? I X
17. Is system reset for normal conditions? I X
18. Is system restored to operational service? I X
19. Have Proper Authorities (see#1)been notified system is back in service? I X
List Proper Authorities:Cal Are
20. Indicate%of equipment tested this report 25% 50% 75% ✓ 00%
21. Indicate %of equipment tested YTD 25% 50% 75% 00%
Comments for any"no"answers or explanations (Note#):
2/24/20 C6V5W—
Owners Rep Sign: Date: Inspector Sign:
ALARM AND DETECTION REPORT Page 3 4 of
Property Site: DURHAM INTERMEDIATE SCHOOL
•
DEVICE zone
DEVICE
TYPE DEVICE LOCATION PASS FAIL NOTE# CHANNEL M
PS BOYS LOCKER ROOM X 1 1
PS NORTH GYM X 1 2
PS SOUTH WEST GYM X 1 3
PS SOUTH EXIT X 1 4
PS 1 ROOM 12 X 1 6
PS ROOM 13 X 1 7
PS ROOM 1-1 X 1 8
PS ROOM 10 X 1 9
PS ROOM 9 X 1 10
PS ROOM 8 X 1 11
PS LIBRARY X 1 12
PS ROOM 6 X 1 13
PS ROOM 7 X 1 14
PS ROOM 5 X 1 15
PS ROOM 4 X 1 16
PS STAFF BREAK ROOM X 1 17
PS MAIN OFFICE X 1 18
PS OFFICE EAST X 1 19
PS ROOM 3 X 1 20
PS ROOM 2 X 1 21
PS ROOM 1 X 1 22
PS ROOM 15 X 1 24
PSD ABOVE FACP X 1 23
Owners RepSign: 2/24/20
9n: Date: Inspector Sign:
ALARM AND DETECTION REPORT DURHAM INTERMEDIATE SCHOOL Page 4 of 4
Zone or DEVICE
DEVICE SLC
TYPE DEVICE LOCATION PASS FAIL NOTE # CHANNEL
1
I �
1 I 1
I I l
I I I 1
I
I I
I I I
LEGEND
PSD—Photoelectric Smoke Detector BD —Beam Detector H—Horn V—Visual
ISD—Ionization Smoke Detector PS—Pull Station WPH—Weather Proof Horn TS—Tamper Switch
PDD —Photo Duct Smoke Detector RR—Rate of Rise Heat Detector C—Chime WF —Water Flow Switch
IDD—Ion Duct Smoke Detector HI —FixedTempHeatDetector CVV —Chime Visual DH—Door Holder
DHS—Door Holder & Smoke Detector FD --Flame Detector S—Speaker OSY —Outside Stern &Yoke Tamper Valve
SSD —Signal Station Srnoke Detector AV—Audihle Visual PIV—Pnct Inrlinator Valve
Cur - Elevator Curtains FRD - Fire Rolldown Door SDC Smoke Detector & Door Holder Combo
CO - Carbon Monoxide Detector
NOTE # COMMENT
See Discrepancy Report
2/24/20 66)34;1—
Owners Rep Sign: _ _ �__T_� Date: —_ Inspector Sign: